HOURLY ANALYSIS PROGRAM
v5.00 and v5.01
Carrier Software Systems
Carrier Corporation
Syracuse, New York
Rev. November 3, 2016
Copyright © 2016 Carrier Corporation, All Rights Reserved
Contents
2
Chiller Features
Air-Side Features
Wizard Features
Other Changes
CHILLER FEATURES
3
HAP
5.01
4
Updated Chiller Import
Details: Carrier’s Electronic Catalog (ECAT) can export performance data for air-
cooled chillers with heat recovery features. HAP can now import and utilize this
data in energy simulations.
Figures show HAP input screens.
HAP
5.01
AIR-SIDE FEATURES
5
HAP
5.00
6
Variable Speed Rotary VRF
Details: Added simulation performance curves for variable speed rotary
compressor VRF condensing units. With this addition, HAP now offers three types
of performance models for VRF: variable speed rotary, variable speed scroll, and
digital scroll.
Figures show the HAP detailed input screens.
HAP
5.00
7
Variable Speed Rotary VRF
Details: Inputs specify capacity, EER, COP, compressor type, and controls. During
energy simulation HAP applies these inputs to the performance curves to create a
scaled performance model for the VRF condensing unit. The model then
calculates how efficiency changes each hour with changing operating conditions.
Figures show the HAP wizard screens.
HAP
5.00
8
ASHRAE Std. 62.1-2013
Details: ASHRAE Standard 62.1-2013 ventilation defaults has been added, as
well as Ventilation Rate Procedure sizing calculations.
HAP
5.00
9
Ventilation Sizing Summary Report
Details: New layout for
terminal systems clarifies
sizing of zone ventilation
airflow and DOAS airflow:
New table
summarizes
system ventilation
requirements
Zones now listed
separately, with
individual per-zone
totals. This better
reflects actual
sizing calculation
procedures.
HAP
5.00
10
DOAS Terminology
Details: Updated terminology to consistently use “Dedicated Outdoor Air System”
(or DOAS) throughout the program.
HAP
5.00
WIZARD FEATURES
11
12
Waterside Economizer for Air-Cooled Chiller Plants
Details: This feature models a cooling tower used for direct cooling duty alongside
air-cooled chillers, when ambient conditions allow. Integrated and non-integrated
configurations are supported. This complements existing features for water-cooled
chiller plants.
HAP
5.00
13
US Energy Information Administration (EIA) Rates
Details: The Utility Rate Wizard has been updated with 2014 EIA rates for gas and
electricity. (2014 data was the latest available at time of release).
HAP
5.00
14
Interoperability Among Wizards
1. Weather location
automatically selects
EIA utility rates (where
available)
2. Building type
automatically selects
equipment operating
schedule
Automatic selections can be
overridden
HAP
5.00
OTHER FEATURES
15
16
Import from Carrier Building System Optimizer
Details: Projects created in Building System Optimizer (BSO) can now be loaded
into HAP. Once imported, full HAP capabilities can be used.
This facilitates scenarios where schematic design was done in BSO but further
detailed design or analysis is required.
HAP
5.00
17
Export to Comma Separated Values (CSV) Files
Details: CSV is a common file format compatible with spreadsheets such as
Microsoft Excel and other software. Energy simulation results for air systems,
plants, and buildings can now be output in this format.
HAP
5.00
Bugs / Corrections (v5.01)
The following problems were corrected:
1. Plant Simulations – Air-cooled chillers imported from ECAT could show excess energy consumption when in
water-cooled heat recovery mode during low-load conditions.
2. Publish to ECAT – When publishing sizing results to ECAT an error occurred when the peak month for a cooling
coil happened to be the winter / heating design condition.
3. Spaces Search & Replace – Fixed problem preventing all choices from being listed for space usage type for
projects using ASHRAE 62.1-2013.
4. General – Eliminated occasional runtime error on computers with missing “MS Sans Serif” font.
5. General – Fixed problem which prevented disabling the “What’s New” screen.
18
HAP
5.01
Bugs / Corrections (v5.00)
The following problems were corrected:
1. Air System Inputs – When the “90.1 Appendix G Fan kW” option was selected for supply fan performance, the
button to display the A-Factor Calculations input screen appeared in the wrong position on the screen, obscuring
other inputs.
2. System Design Reports – For an induction beam or active chilled beam system in which a zone contains multiple
spaces, and in which the zone primary airflow is set by induction supply requirements rather than outdoor air
ventilation requirement, the Ventilation Sizing Summary report showed incorrect Voz values for spaces in that
zone. This was a cosmetic error. Calculation of ventilation airflow requirements for the system was correct.
3. Building Simulation I – It was possible to create a complex electric rate with zero energy charge steps. If that
electric rate was used in a building simulation an error message appeared.
4. Building Simulation II – The unmet load hours shown on the LEED EAc1 report incorrectly included unmet loads
for service hot water (SHW), but should only contain data for space conditioning. This only occurred for projects
modeling a standalone SHW system.
5. Building Wizard – When a wall, roof, or window assembly created in the detailed user interface was selected in
the Building Wizard, the overall U-value was shown as zero. In addition, an error occurred when generating the
Building Wizard input report. These were cosmetic errors; inputs were successfully transformed into spaces,
assemblies and schedules for the detailed HAP interface and were reliable for use in load calculations and energy
simulations.
6. Utility Rate Wizard – When price data for remote steam was entered, it was incorrectly assigned to the remote
hot water meter in the building.
7. Reports – Under specific conditions an “Error 521: Unable to open clipboard” error occurred when generating
certain reports.
8. gbXML Import – For a very specific set of conditions the gbXML Import feature linked the wrong window or door
assembly to spaces. This only occurred when window names exceeded 30 characters, and the first 30 characters
of each name matched other names.
9. Example Problem Results PDF – Example problem results listed in the Example Problems Results PDF
document did not match results produced by the HAP v4.9 example problem. This PDF document is used by
customers performing validation of the program.
19
HAP
5.00
20
QUESTIONS?
If you have any questions about Carrier Hourly Analysis Program v5.01
please contact Carrier Software Systems at
software.systems@carrier.utc.com
Thank you!

More Related Content

PDF
Guia HAP para LG MultiV
PDF
AFT Fathom 11 - Recursos
PDF
meteodyn WT 5.0 new features
PPTX
CoolSim Overview
PDF
Presentation v mware roi tco calculator
PDF
Chvac software tutorial
PDF
Rit 8.5.0 training release notes
PDF
Eclipse SCADA
Guia HAP para LG MultiV
AFT Fathom 11 - Recursos
meteodyn WT 5.0 new features
CoolSim Overview
Presentation v mware roi tco calculator
Chvac software tutorial
Rit 8.5.0 training release notes
Eclipse SCADA

Similar to E20S-FEATURES-HAP501-HAP 5.01-New Features Guide.pdf (20)

PDF
Design the implementation of CDEx Robust DC Motor.
PDF
325546_adding fields in CJI3 & CJI5.pdf
PDF
2014 PV Performance Modeling Workshop: Optimizing PV Designs with HelioScope:...
PPT
Oracle fixed assets
PDF
PORTFOLIO_MJ
PDF
PV Elite 2019 Service Pack 2 (Version 21.00.02.0000).
PDF
Sprint 140
PPTX
Optimize power and cooling final 1
PDF
Thinking Outside the Box – Server Design for #DataCenter Optimization
PDF
Electroneumática: Fluidísim con electroneumática
DOCX
2232016 Sample Implementation Plan1.htmlfileCUsers.docx
DOC
Windows server power_efficiency___robben_and_worthington__final
PDF
51 b wittmer_latest_features_of_p_vsyst
PPTX
Optimize power and cooling final
PPTX
Detechtion - Sales Presentation (2-27-23)(1).pptx
PPTX
Aerospace maintenance facility increases utilization by 50%, saves money
DOCX
Sap bpc Planning and consolidation
PDF
Info plc net_dcs800_controlbuilder_basic_exercises
PDF
Custom lab 12
PDF
Sprint 138
Design the implementation of CDEx Robust DC Motor.
325546_adding fields in CJI3 & CJI5.pdf
2014 PV Performance Modeling Workshop: Optimizing PV Designs with HelioScope:...
Oracle fixed assets
PORTFOLIO_MJ
PV Elite 2019 Service Pack 2 (Version 21.00.02.0000).
Sprint 140
Optimize power and cooling final 1
Thinking Outside the Box – Server Design for #DataCenter Optimization
Electroneumática: Fluidísim con electroneumática
2232016 Sample Implementation Plan1.htmlfileCUsers.docx
Windows server power_efficiency___robben_and_worthington__final
51 b wittmer_latest_features_of_p_vsyst
Optimize power and cooling final
Detechtion - Sales Presentation (2-27-23)(1).pptx
Aerospace maintenance facility increases utilization by 50%, saves money
Sap bpc Planning and consolidation
Info plc net_dcs800_controlbuilder_basic_exercises
Custom lab 12
Sprint 138
Ad

Recently uploaded (20)

PDF
intro_to_rust.pptx_123456789012446789.pdf
PPTX
Acoustics new a better way to learn sound science
PDF
The Basics of Presentation Design eBook by VerdanaBold
PPTX
2. Competency Based Interviewing - September'16.pptx
PDF
trenching-standard-drawings procedure rev
PPTX
Project_Presentation Bitcoin Price Prediction
PDF
Trends That Shape Graphic Design Services
PDF
2025CategoryRanking of technology university
PPTX
Evolution_of_Computing_Presentation (1).pptx
PPTX
UNIT III - GRAPHICS AND AUDIO FOR MOBILE
PDF
SOUND-NOTE-ARCHITECT-MOHIUDDIN AKHAND SMUCT
PDF
The Complete Guide to Buying Verified Stripe Accounts 2025.pdf
PDF
How Animation is Used by Sports Teams and Leagues
PPTX
CLASS_11_BUSINESS_STUDIES_PPT_CHAPTER_1_Business_Trade_Commerce.pptx
PPTX
UI UX Elective Course S1 Sistem Informasi RPS.pptx
PDF
analisis snsistem etnga ahrfahfffffffffffffffffffff
PDF
GSH-Vicky1-Complete-Plans on Housing.pdf
PDF
2025_AIFG_Akane_Kikuchi_Empathy_Design.PDF
PDF
Test slideshare presentation for blog post
PPTX
Introduction to Building Information Modeling
intro_to_rust.pptx_123456789012446789.pdf
Acoustics new a better way to learn sound science
The Basics of Presentation Design eBook by VerdanaBold
2. Competency Based Interviewing - September'16.pptx
trenching-standard-drawings procedure rev
Project_Presentation Bitcoin Price Prediction
Trends That Shape Graphic Design Services
2025CategoryRanking of technology university
Evolution_of_Computing_Presentation (1).pptx
UNIT III - GRAPHICS AND AUDIO FOR MOBILE
SOUND-NOTE-ARCHITECT-MOHIUDDIN AKHAND SMUCT
The Complete Guide to Buying Verified Stripe Accounts 2025.pdf
How Animation is Used by Sports Teams and Leagues
CLASS_11_BUSINESS_STUDIES_PPT_CHAPTER_1_Business_Trade_Commerce.pptx
UI UX Elective Course S1 Sistem Informasi RPS.pptx
analisis snsistem etnga ahrfahfffffffffffffffffffff
GSH-Vicky1-Complete-Plans on Housing.pdf
2025_AIFG_Akane_Kikuchi_Empathy_Design.PDF
Test slideshare presentation for blog post
Introduction to Building Information Modeling
Ad

E20S-FEATURES-HAP501-HAP 5.01-New Features Guide.pdf

  • 1. HOURLY ANALYSIS PROGRAM v5.00 and v5.01 Carrier Software Systems Carrier Corporation Syracuse, New York Rev. November 3, 2016 Copyright © 2016 Carrier Corporation, All Rights Reserved
  • 4. 4 Updated Chiller Import Details: Carrier’s Electronic Catalog (ECAT) can export performance data for air- cooled chillers with heat recovery features. HAP can now import and utilize this data in energy simulations. Figures show HAP input screens. HAP 5.01
  • 6. 6 Variable Speed Rotary VRF Details: Added simulation performance curves for variable speed rotary compressor VRF condensing units. With this addition, HAP now offers three types of performance models for VRF: variable speed rotary, variable speed scroll, and digital scroll. Figures show the HAP detailed input screens. HAP 5.00
  • 7. 7 Variable Speed Rotary VRF Details: Inputs specify capacity, EER, COP, compressor type, and controls. During energy simulation HAP applies these inputs to the performance curves to create a scaled performance model for the VRF condensing unit. The model then calculates how efficiency changes each hour with changing operating conditions. Figures show the HAP wizard screens. HAP 5.00
  • 8. 8 ASHRAE Std. 62.1-2013 Details: ASHRAE Standard 62.1-2013 ventilation defaults has been added, as well as Ventilation Rate Procedure sizing calculations. HAP 5.00
  • 9. 9 Ventilation Sizing Summary Report Details: New layout for terminal systems clarifies sizing of zone ventilation airflow and DOAS airflow: New table summarizes system ventilation requirements Zones now listed separately, with individual per-zone totals. This better reflects actual sizing calculation procedures. HAP 5.00
  • 10. 10 DOAS Terminology Details: Updated terminology to consistently use “Dedicated Outdoor Air System” (or DOAS) throughout the program. HAP 5.00
  • 12. 12 Waterside Economizer for Air-Cooled Chiller Plants Details: This feature models a cooling tower used for direct cooling duty alongside air-cooled chillers, when ambient conditions allow. Integrated and non-integrated configurations are supported. This complements existing features for water-cooled chiller plants. HAP 5.00
  • 13. 13 US Energy Information Administration (EIA) Rates Details: The Utility Rate Wizard has been updated with 2014 EIA rates for gas and electricity. (2014 data was the latest available at time of release). HAP 5.00
  • 14. 14 Interoperability Among Wizards 1. Weather location automatically selects EIA utility rates (where available) 2. Building type automatically selects equipment operating schedule Automatic selections can be overridden HAP 5.00
  • 16. 16 Import from Carrier Building System Optimizer Details: Projects created in Building System Optimizer (BSO) can now be loaded into HAP. Once imported, full HAP capabilities can be used. This facilitates scenarios where schematic design was done in BSO but further detailed design or analysis is required. HAP 5.00
  • 17. 17 Export to Comma Separated Values (CSV) Files Details: CSV is a common file format compatible with spreadsheets such as Microsoft Excel and other software. Energy simulation results for air systems, plants, and buildings can now be output in this format. HAP 5.00
  • 18. Bugs / Corrections (v5.01) The following problems were corrected: 1. Plant Simulations – Air-cooled chillers imported from ECAT could show excess energy consumption when in water-cooled heat recovery mode during low-load conditions. 2. Publish to ECAT – When publishing sizing results to ECAT an error occurred when the peak month for a cooling coil happened to be the winter / heating design condition. 3. Spaces Search & Replace – Fixed problem preventing all choices from being listed for space usage type for projects using ASHRAE 62.1-2013. 4. General – Eliminated occasional runtime error on computers with missing “MS Sans Serif” font. 5. General – Fixed problem which prevented disabling the “What’s New” screen. 18 HAP 5.01
  • 19. Bugs / Corrections (v5.00) The following problems were corrected: 1. Air System Inputs – When the “90.1 Appendix G Fan kW” option was selected for supply fan performance, the button to display the A-Factor Calculations input screen appeared in the wrong position on the screen, obscuring other inputs. 2. System Design Reports – For an induction beam or active chilled beam system in which a zone contains multiple spaces, and in which the zone primary airflow is set by induction supply requirements rather than outdoor air ventilation requirement, the Ventilation Sizing Summary report showed incorrect Voz values for spaces in that zone. This was a cosmetic error. Calculation of ventilation airflow requirements for the system was correct. 3. Building Simulation I – It was possible to create a complex electric rate with zero energy charge steps. If that electric rate was used in a building simulation an error message appeared. 4. Building Simulation II – The unmet load hours shown on the LEED EAc1 report incorrectly included unmet loads for service hot water (SHW), but should only contain data for space conditioning. This only occurred for projects modeling a standalone SHW system. 5. Building Wizard – When a wall, roof, or window assembly created in the detailed user interface was selected in the Building Wizard, the overall U-value was shown as zero. In addition, an error occurred when generating the Building Wizard input report. These were cosmetic errors; inputs were successfully transformed into spaces, assemblies and schedules for the detailed HAP interface and were reliable for use in load calculations and energy simulations. 6. Utility Rate Wizard – When price data for remote steam was entered, it was incorrectly assigned to the remote hot water meter in the building. 7. Reports – Under specific conditions an “Error 521: Unable to open clipboard” error occurred when generating certain reports. 8. gbXML Import – For a very specific set of conditions the gbXML Import feature linked the wrong window or door assembly to spaces. This only occurred when window names exceeded 30 characters, and the first 30 characters of each name matched other names. 9. Example Problem Results PDF – Example problem results listed in the Example Problems Results PDF document did not match results produced by the HAP v4.9 example problem. This PDF document is used by customers performing validation of the program. 19 HAP 5.00
  • 20. 20 QUESTIONS? If you have any questions about Carrier Hourly Analysis Program v5.01 please contact Carrier Software Systems at software.systems@carrier.utc.com Thank you!