High-efficiency heat recovery
high-efficiency with rotary recovery unit.
Air flow rates from 1,000 to 30,000 m3/h.ERSR
Features
The ERSR heat recovery units for indoor and out-
door installation are designed for commercial
applications and are able to combine maximum
environmental comfort with definite energy sav-
ing.
With modern systems, there is always the need to
create forced ventilation, which, however, also
involves expelling air-conditioned air, which thus
leads to higher energy consumption.
But ERSR units are equipped with a rotary heat
recovery unit (upon request, also hygroscopic
rotary) that enables you to save more than 80% of
the energy that would otherwise be lost with the
expelled stale air.
These units can be integrated with fan coils and
chillers, and can operate both in winter and sum-
mer.
Versions
ERSR_T	 with a sensitive rotary recovery
ERSR_H	 with a hygroscopic rotary recovery
•	 Rotary heat recovery unit (with the option in
hygroscopic material), high-efficiency and low
pressure drops.
• Soft air bag F7 filters (flow and recovery)
equipped with a standard differential pressure
switch, which can be extracted from either side
facilitate their periodic cleaning.
• Fans (intake and flow), Plug fan with back curved
blades with a directly coupled, electronically
controlled motor for sizes 07-17 and with an
inverter for sizes 21-24.
•	 Support frame and sandwich panels, 50 mm
thick, in galvanised sheet steel for internal sur-
faces and pre-painted externally, and with min-
eral wool insulation (density 40 kg/m3).
	 Upon request, there are two different types of
panelling.
	 Base in galvanised sheet steel continuous pro-
files. Sizes 07 to 09 are monoblocs whilst the
other sizes are divided into sections. The unit
can be inspected from both sides.
•	 The unit is equipped with a power electric con-
trol board on the machine and adjustment pur-
posely designed to reduce energy consump-
tion. Equipped with a communication serial
port on RS485 with MODBUS Master/Slave pro-
tocol
•	MECHANICALLY CONTROLLED VENTILATION
•	ROTARY HEAT RECOVERY UNIT
•	RECOVERY OF UP TO 80% OF THE ENERGY OF THE
EXPELLED AIR
•	AIR PURIFICATION
Accessories
•	 CAP Intake rainproof cover
•	 BDL Flow rainproof cover
•	 FRR Rectangular flange
•	 GAR rectangular anti-vibration joint
•	 HSR Fresh air intake damper with
servocontrol
•	 RSR Circulation damper module
•	 HG4 Flat filters G4
•	 TDP roof protection for basic unit in the case
of outdoor installation
•	 VRC condensate drip tray
•	 VVR Variable speed recovery unit
•	 QP Air quality probe (VOC)
•	 KDP Dehumidification and post-heating
management kit
•	 RBC 3-way valve hot water coil module
•	 RBF 3-way valve cold water coil module
•	 RBE electric coil module
•	 RBP 3-way valve cold water and post-
heating coil module
•	 MSS silencer baffles module
TECHNOLOGY
HIGH
EFFICIENCY
Accessories compatibility
Features
ERSR 07 09 12 15 17 21 24
UNIT ACCESSORIES
CAP CAP07 CAP09 CAP12 CAP15 CAP17 CAP21 CAP24
BDL BDL07 BDL09 BDL12 BDL15 BDL17 BDL21 BDL24
FRR FRR09 FRR09 FRR12 FRR15 FRR17 FRR21 FRR24
GAR GAR07 GAR09 GAR12 GAR15 GAR17 GAR21 GAR24
HSR HSR07 HSR09 HSR12 HSR15 HSR17 HSR21 HSR24
RSR - - HSR12 RSR15 RSR17 RSR21 RSR24
HG4 HG407 HG409 HG412 HG415 HG417 HG421 HG424
TDP TDP07 TDP09 TDP12 TDP15 TDP17 TDP21 TDP24
VRC VRC07 VRC09 VRC12 VRC15 VRC17 VRC21 VRC24
VVR VVR07 VVR09 VVR12 VVR15 VVR17 VVR21 VVR24
QP • • • • • • •
KDP • • • • • • •
MODULE ACCESSORIES
RBC RBC07 RBC09 RBC12 RBC15 RBC17 RBC21 RBC24
RBF RBF07 RBF09 RBF12 RBF15 RBF17 RBF21 RBF24
RBE RBE07 RBE09 RBE12 RBE15 RBE17 RBE21 RBE24
RBP RBP07 RBP09 RBP12 RBP15 RBP17 RBP21 RBP24
MSS MSS07 MSS09 MSS12 MSS15 MSS17 MSS21 MSS24
MODULE ACCESSORIESWITH ROOF (for outdoor installations)
RBCT RBC07T RBC09T RBC12T RBC15T RBC17T RBC21T RBC24T
RBFT RBF07T RBF09T RBF12T RBF15T RBF17T RBF21T RBF24T
RBET RBE07T RBE09T RBE12T RBE15T RBE17T RBE21T RBE24T
RBPT RBP07T RBP09T RBP12T RBP15T RBP17T RBP21T RBP24T
MSST MSS07T MSS09T MSS12T MSS15T MSS17T MSS21T MSS24T
Quality of the air
Nowadays, the quality of air inside rooms is funda-
mental. The mechanically controlled ventilation
system is not only indispensable from an energetic
point of view, but also for the comfort of the
rooms.
Harmful elements and smells in the air are elimi-
nated by the efficient filtration system with bag fil-
ters (F7), which are easily extracted and regenerat-
ed.
High-efficiency air circulation thanks to
plug-fans with electronically controlled motors
or inverters, depending on the sizes
•	 It eliminates inefficiency, wear and maintenance
of traditional fans with belt and pulley transmis-
sion
•	 	They guarantee energy savings of up to 30%
compared to traditional fans. The control lets you
calibrate the fan's speed according to your
requirements, thus optimising seasonal efficien-
cy
High-efficiency recovery unit (80% of the ener-
gy of the expelled air)
Air heat recovery both in summer and winter,
thanks to the rotary recovery unit (hygroscopic
version also available). Air introduced into the
room is always optimised, thanks to the heat
exchange between the air recovery and outdoor
fresh air.
State of the art electronic control
Naturally, all these technological advantages are
controlled by state of the art heat regulation, thus
ensuring maximum energy savings in every condi-
tion of use.
Air expelled
Air recovery from the room
Outdoor fresh air
Air introduced into the room
Technical data
Mod. ERSR 07T 09T 12T 15T 17T 21T 24T
Nominal air flow and recovery flow rate m3/h 1.100 1.950 3.700 5.950 7.800 12.200 16.100
Maximum air flow and recovery static pressure available Pa 420 660 1.100 1.120 1.040 1.440 1.530
Total nominal input power (1) kW 0,33 0,48 1,06 1,69 2,13 3,49 3,85
Maximum air flow and recovery flow rate m3/h 2.000 4.370 5.880 10.650 14.800 24.750 31.350
Total maximum input power kW 0,84 2,04 6,09 8,78 10,18 22,37 30,37
Total heating capacity recovered kW 10,7 19 36 57,9 75,9 118 156
Recovered sens. heating capacity kW 7,4 13,1 24,9 40,1 52,5 82,1 108
Winter recovery unit efficiency % 80 80 80 80 80 80 80
Total recovered cooling capacity kW 2,8 4,9 9,3 14,9 19,5 30,5 40,3
Recovered sens. cooling capacity kW 2,7 4,7 9 14,4 18,9 29,6 39
Summer recovery unit efficiency % 80 80 80 80 80 80 80
Total number of fans n° 2 2 2 2 2 4 4
Sound power level dB(A) 65,6 67 75,3 76,7 78 78 79
Unit power supply V/h/Hz 400V/3N/50Hz
RBC Hot water coil
Heating capacity (2) kW 9,5 16,9 27,4 46,7 60,1 95,8 130,4
Water flow rate (2) m3/h 0,8 1,4 2,3 4 5,2 8,4 11,3
Water side pressure drop (2) kPa 9 8 8 7 11 16 20
RBF Cold water coil
Total cooling capacity (3) kW 10,5 19,5 34,7 59,8 80 127,4 171,3
Sensitive cooling capacity (3) kW 4,1 7,6 13,9 23,9 32 51 68,5
Water flow rate (3) m3/h 1,6 2,9 6 10,3 13,7 21,9 29,5
Water side pressure drop (3) kPa 15 8 7 23 33 34 3,2
For the performance of the H version, contact the head office.
Heating
Fresh air flow rate equal to the air expulsion flow rate; Outdoor air temperature (in) -5°C 80% r.h.; Room temperature 20°C, 50% r.h.
Cooling mode
Fresh air flow rate equal to the air expulsion flow rate; Outdoor air temperature (in) 35°C 50% r.h.; Room temperature 26°C, 50% r.h.
(1) 	 With nominal air flow rates and useful pressure of 100Pa.
(2) 	 Coil water inlet temperature 70°C; Coil inlet-outlet temperature difference 10°C; Coil air intake temperature 15°C;
	 Water pressure drops not included with a 3-way valve (standard).
(3) 	Coil water inlet temperature 7°C; Coil inlet-outlet temperature difference 5°C; Coil air intake temperature 28°C, 75% RH;
Water pressure drops not inclusive with a 3-way valve (standard).
Sound power level of the flow fan not ducted with useful static pressure equivalent to 0 Pa.
Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577
www.aermec.com
All specifications are subject to change without prior notice.
Although every effort has been made to ensure accuracy, Aermec
does not assume responsibility or liability for eventual errors or
omissions.
ERSR 07 09 12 15 17 21 24
Height A mm 965 1285 1445 1765 2085 2405 2725
Width B mm 895 1005 1375 1695 1855 2335 2665
Depth C mm 1375 1535 2045 2365 2365 3005 3005
Weight kg 240 340 570 820 1010 1610 1980
ERSR_Y_UN50_00
Dimensional data (mm)
A
120
B
C
Horizontal installation

More Related Content

PDF
Ank y na60_00
PPT
Load Match Next Generation
PDF
Water Cooled Portable Air Conditioners
PDF
Urhe cf y-un50_00
PPTX
AERMEC 2013 Presentation
PDF
High-Efficiency Heating Rooftop Units (RTUs): The Final Frontier for Condensi...
PDF
Hp heater ch-8.3
PDF
HVAC Service Class
Ank y na60_00
Load Match Next Generation
Water Cooled Portable Air Conditioners
Urhe cf y-un50_00
AERMEC 2013 Presentation
High-Efficiency Heating Rooftop Units (RTUs): The Final Frontier for Condensi...
Hp heater ch-8.3
HVAC Service Class

What's hot (20)

PDF
Wrl hp y-na60_00
PDF
Chapter8
PPT
Ventilation
PDF
G y un50_00
PDF
Rpf y un50_00
PPT
13 Us Vrv Vrv S Us Installs
PDF
Trane Cube
PPTX
VRF II VRV
PDF
Table 6.3.2
PPTX
Heat tracing ppt
PDF
Dekon Rooftop units t3 conditions
PDF
DEKON R410a packaged rooftop units
PDF
Manual de ingeniería bohn
PPTX
Hvac basics
PDF
Dvm hydro sales Presentation
PDF
Rittal - Re-Cooling - Chiller Ürünleri
PDF
Dekon Modular ahu
PPTX
AIChE 2018 improving catalytic reformer heaters using split flow technology rev2
PPTX
Cooling System
Wrl hp y-na60_00
Chapter8
Ventilation
G y un50_00
Rpf y un50_00
13 Us Vrv Vrv S Us Installs
Trane Cube
VRF II VRV
Table 6.3.2
Heat tracing ppt
Dekon Rooftop units t3 conditions
DEKON R410a packaged rooftop units
Manual de ingeniería bohn
Hvac basics
Dvm hydro sales Presentation
Rittal - Re-Cooling - Chiller Ürünleri
Dekon Modular ahu
AIChE 2018 improving catalytic reformer heaters using split flow technology rev2
Cooling System
Ad

Similar to Ersr y un50_00 (20)

PDF
Urhe cf y-un50_00
PDF
Rtx 17-23 y-un50_00
PDF
42GWC Hydronic Cassette Fan Coil Units.pdf
PDF
4DES-7; R404A; t0 -5; tc 45.pdf for CS S
PDF
Crac precision climate_control_units_for_data_centres
PDF
Powerstream Turbo chiller
PPTX
AIChE Smart Stack Damper Design Provides Better Control of Fired Heaters
PDF
Rte 1 en
PDF
Sb ls freecool-screw-inverter_1.2_en
PDF
ELGI Airmate Air Accessories Total Compressed Air Solutions
PDF
Sb ls screw-fixed-speed_ver.3.0_en
PDF
Toshiba
PDF
Compressed Air Treatment Systems | CS Industrial Services | New York
PDF
Clean Air System Catalog RAX Series Made in Japan D AG
PDF
P y un50_00
PPTX
Hvac - presentation (Air conditioning presentation)
PDF
Sb ls scroll_ver.3.0_en
PDF
Experimental investigation of waste heat recovery system for domestic refrige...
PPTX
HVAC_System_Survey_Presentation.pptx
PPTX
HVAC_System_Survey_Presentation.pptx
Urhe cf y-un50_00
Rtx 17-23 y-un50_00
42GWC Hydronic Cassette Fan Coil Units.pdf
4DES-7; R404A; t0 -5; tc 45.pdf for CS S
Crac precision climate_control_units_for_data_centres
Powerstream Turbo chiller
AIChE Smart Stack Damper Design Provides Better Control of Fired Heaters
Rte 1 en
Sb ls freecool-screw-inverter_1.2_en
ELGI Airmate Air Accessories Total Compressed Air Solutions
Sb ls screw-fixed-speed_ver.3.0_en
Toshiba
Compressed Air Treatment Systems | CS Industrial Services | New York
Clean Air System Catalog RAX Series Made in Japan D AG
P y un50_00
Hvac - presentation (Air conditioning presentation)
Sb ls scroll_ver.3.0_en
Experimental investigation of waste heat recovery system for domestic refrige...
HVAC_System_Survey_Presentation.pptx
HVAC_System_Survey_Presentation.pptx
Ad

More from Oliverh Kalprit (20)

PDF
Tubommzen
PDF
Blsileodesignleaflet201802en
PDF
PDF
Nlc 0280-1250-co y-un50_00
PDF
Bltower svshleaflet201804en
PDF
Trs y un50_00
PDF
Mva mono y-un50_00
PDF
Nrp 0800-1800-hp-t y-un50_00
PDF
Vento expert duo_a30_1_wen
PDF
Komforteclblbeen
PDF
Sc y un50_00
PDF
R y un50_00
PDF
Bavaria100 catalog
PDF
Ta y sa60_00
PDF
Nlc co y-na60_02
PDF
Ventosolarv60propro2en
PDF
Blturboleaflet201804en
PDF
PDF
Smartiren
PDF
Ventoergoa251proen
Tubommzen
Blsileodesignleaflet201802en
Nlc 0280-1250-co y-un50_00
Bltower svshleaflet201804en
Trs y un50_00
Mva mono y-un50_00
Nrp 0800-1800-hp-t y-un50_00
Vento expert duo_a30_1_wen
Komforteclblbeen
Sc y un50_00
R y un50_00
Bavaria100 catalog
Ta y sa60_00
Nlc co y-na60_02
Ventosolarv60propro2en
Blturboleaflet201804en
Smartiren
Ventoergoa251proen

Recently uploaded (20)

PDF
August 2025 - Top 10 Read Articles in Network Security & Its Applications
PPTX
Chapter 2 -Technology and Enginerring Materials + Composites.pptx
PDF
Prof. Dr. KAYIHURA A. SILAS MUNYANEZA, PhD..pdf
PPTX
wireless networks, mobile computing.pptx
PDF
Soil Improvement Techniques Note - Rabbi
PDF
distributed database system" (DDBS) is often used to refer to both the distri...
PPTX
PRASUNET_20240614003_231416_0000[1].pptx
PDF
MLpara ingenieira CIVIL, meca Y AMBIENTAL
PPTX
Amdahl’s law is explained in the above power point presentations
PPTX
AUTOMOTIVE ENGINE MANAGEMENT (MECHATRONICS).pptx
PDF
Accra-Kumasi Expressway - Prefeasibility Report Volume 1 of 7.11.2018.pdf
PDF
Influence of Green Infrastructure on Residents’ Endorsement of the New Ecolog...
PDF
August -2025_Top10 Read_Articles_ijait.pdf
PPTX
CN_Unite_1 AI&DS ENGGERING SPPU PUNE UNIVERSITY
PPTX
A Brief Introduction to IoT- Smart Objects: The "Things" in IoT
PDF
Computer System Architecture 3rd Edition-M Morris Mano.pdf
PPTX
mechattonicsand iotwith sensor and actuator
PPTX
Chemical Technological Processes, Feasibility Study and Chemical Process Indu...
PDF
First part_B-Image Processing - 1 of 2).pdf
PDF
Cryptography and Network Security-Module-I.pdf
August 2025 - Top 10 Read Articles in Network Security & Its Applications
Chapter 2 -Technology and Enginerring Materials + Composites.pptx
Prof. Dr. KAYIHURA A. SILAS MUNYANEZA, PhD..pdf
wireless networks, mobile computing.pptx
Soil Improvement Techniques Note - Rabbi
distributed database system" (DDBS) is often used to refer to both the distri...
PRASUNET_20240614003_231416_0000[1].pptx
MLpara ingenieira CIVIL, meca Y AMBIENTAL
Amdahl’s law is explained in the above power point presentations
AUTOMOTIVE ENGINE MANAGEMENT (MECHATRONICS).pptx
Accra-Kumasi Expressway - Prefeasibility Report Volume 1 of 7.11.2018.pdf
Influence of Green Infrastructure on Residents’ Endorsement of the New Ecolog...
August -2025_Top10 Read_Articles_ijait.pdf
CN_Unite_1 AI&DS ENGGERING SPPU PUNE UNIVERSITY
A Brief Introduction to IoT- Smart Objects: The "Things" in IoT
Computer System Architecture 3rd Edition-M Morris Mano.pdf
mechattonicsand iotwith sensor and actuator
Chemical Technological Processes, Feasibility Study and Chemical Process Indu...
First part_B-Image Processing - 1 of 2).pdf
Cryptography and Network Security-Module-I.pdf

Ersr y un50_00

  • 1. High-efficiency heat recovery high-efficiency with rotary recovery unit. Air flow rates from 1,000 to 30,000 m3/h.ERSR Features The ERSR heat recovery units for indoor and out- door installation are designed for commercial applications and are able to combine maximum environmental comfort with definite energy sav- ing. With modern systems, there is always the need to create forced ventilation, which, however, also involves expelling air-conditioned air, which thus leads to higher energy consumption. But ERSR units are equipped with a rotary heat recovery unit (upon request, also hygroscopic rotary) that enables you to save more than 80% of the energy that would otherwise be lost with the expelled stale air. These units can be integrated with fan coils and chillers, and can operate both in winter and sum- mer. Versions ERSR_T with a sensitive rotary recovery ERSR_H with a hygroscopic rotary recovery • Rotary heat recovery unit (with the option in hygroscopic material), high-efficiency and low pressure drops. • Soft air bag F7 filters (flow and recovery) equipped with a standard differential pressure switch, which can be extracted from either side facilitate their periodic cleaning. • Fans (intake and flow), Plug fan with back curved blades with a directly coupled, electronically controlled motor for sizes 07-17 and with an inverter for sizes 21-24. • Support frame and sandwich panels, 50 mm thick, in galvanised sheet steel for internal sur- faces and pre-painted externally, and with min- eral wool insulation (density 40 kg/m3). Upon request, there are two different types of panelling. Base in galvanised sheet steel continuous pro- files. Sizes 07 to 09 are monoblocs whilst the other sizes are divided into sections. The unit can be inspected from both sides. • The unit is equipped with a power electric con- trol board on the machine and adjustment pur- posely designed to reduce energy consump- tion. Equipped with a communication serial port on RS485 with MODBUS Master/Slave pro- tocol • MECHANICALLY CONTROLLED VENTILATION • ROTARY HEAT RECOVERY UNIT • RECOVERY OF UP TO 80% OF THE ENERGY OF THE EXPELLED AIR • AIR PURIFICATION Accessories • CAP Intake rainproof cover • BDL Flow rainproof cover • FRR Rectangular flange • GAR rectangular anti-vibration joint • HSR Fresh air intake damper with servocontrol • RSR Circulation damper module • HG4 Flat filters G4 • TDP roof protection for basic unit in the case of outdoor installation • VRC condensate drip tray • VVR Variable speed recovery unit • QP Air quality probe (VOC) • KDP Dehumidification and post-heating management kit • RBC 3-way valve hot water coil module • RBF 3-way valve cold water coil module • RBE electric coil module • RBP 3-way valve cold water and post- heating coil module • MSS silencer baffles module TECHNOLOGY HIGH EFFICIENCY
  • 2. Accessories compatibility Features ERSR 07 09 12 15 17 21 24 UNIT ACCESSORIES CAP CAP07 CAP09 CAP12 CAP15 CAP17 CAP21 CAP24 BDL BDL07 BDL09 BDL12 BDL15 BDL17 BDL21 BDL24 FRR FRR09 FRR09 FRR12 FRR15 FRR17 FRR21 FRR24 GAR GAR07 GAR09 GAR12 GAR15 GAR17 GAR21 GAR24 HSR HSR07 HSR09 HSR12 HSR15 HSR17 HSR21 HSR24 RSR - - HSR12 RSR15 RSR17 RSR21 RSR24 HG4 HG407 HG409 HG412 HG415 HG417 HG421 HG424 TDP TDP07 TDP09 TDP12 TDP15 TDP17 TDP21 TDP24 VRC VRC07 VRC09 VRC12 VRC15 VRC17 VRC21 VRC24 VVR VVR07 VVR09 VVR12 VVR15 VVR17 VVR21 VVR24 QP • • • • • • • KDP • • • • • • • MODULE ACCESSORIES RBC RBC07 RBC09 RBC12 RBC15 RBC17 RBC21 RBC24 RBF RBF07 RBF09 RBF12 RBF15 RBF17 RBF21 RBF24 RBE RBE07 RBE09 RBE12 RBE15 RBE17 RBE21 RBE24 RBP RBP07 RBP09 RBP12 RBP15 RBP17 RBP21 RBP24 MSS MSS07 MSS09 MSS12 MSS15 MSS17 MSS21 MSS24 MODULE ACCESSORIESWITH ROOF (for outdoor installations) RBCT RBC07T RBC09T RBC12T RBC15T RBC17T RBC21T RBC24T RBFT RBF07T RBF09T RBF12T RBF15T RBF17T RBF21T RBF24T RBET RBE07T RBE09T RBE12T RBE15T RBE17T RBE21T RBE24T RBPT RBP07T RBP09T RBP12T RBP15T RBP17T RBP21T RBP24T MSST MSS07T MSS09T MSS12T MSS15T MSS17T MSS21T MSS24T Quality of the air Nowadays, the quality of air inside rooms is funda- mental. The mechanically controlled ventilation system is not only indispensable from an energetic point of view, but also for the comfort of the rooms. Harmful elements and smells in the air are elimi- nated by the efficient filtration system with bag fil- ters (F7), which are easily extracted and regenerat- ed. High-efficiency air circulation thanks to plug-fans with electronically controlled motors or inverters, depending on the sizes • It eliminates inefficiency, wear and maintenance of traditional fans with belt and pulley transmis- sion • They guarantee energy savings of up to 30% compared to traditional fans. The control lets you calibrate the fan's speed according to your requirements, thus optimising seasonal efficien- cy High-efficiency recovery unit (80% of the ener- gy of the expelled air) Air heat recovery both in summer and winter, thanks to the rotary recovery unit (hygroscopic version also available). Air introduced into the room is always optimised, thanks to the heat exchange between the air recovery and outdoor fresh air. State of the art electronic control Naturally, all these technological advantages are controlled by state of the art heat regulation, thus ensuring maximum energy savings in every condi- tion of use. Air expelled Air recovery from the room Outdoor fresh air Air introduced into the room
  • 3. Technical data Mod. ERSR 07T 09T 12T 15T 17T 21T 24T Nominal air flow and recovery flow rate m3/h 1.100 1.950 3.700 5.950 7.800 12.200 16.100 Maximum air flow and recovery static pressure available Pa 420 660 1.100 1.120 1.040 1.440 1.530 Total nominal input power (1) kW 0,33 0,48 1,06 1,69 2,13 3,49 3,85 Maximum air flow and recovery flow rate m3/h 2.000 4.370 5.880 10.650 14.800 24.750 31.350 Total maximum input power kW 0,84 2,04 6,09 8,78 10,18 22,37 30,37 Total heating capacity recovered kW 10,7 19 36 57,9 75,9 118 156 Recovered sens. heating capacity kW 7,4 13,1 24,9 40,1 52,5 82,1 108 Winter recovery unit efficiency % 80 80 80 80 80 80 80 Total recovered cooling capacity kW 2,8 4,9 9,3 14,9 19,5 30,5 40,3 Recovered sens. cooling capacity kW 2,7 4,7 9 14,4 18,9 29,6 39 Summer recovery unit efficiency % 80 80 80 80 80 80 80 Total number of fans n° 2 2 2 2 2 4 4 Sound power level dB(A) 65,6 67 75,3 76,7 78 78 79 Unit power supply V/h/Hz 400V/3N/50Hz RBC Hot water coil Heating capacity (2) kW 9,5 16,9 27,4 46,7 60,1 95,8 130,4 Water flow rate (2) m3/h 0,8 1,4 2,3 4 5,2 8,4 11,3 Water side pressure drop (2) kPa 9 8 8 7 11 16 20 RBF Cold water coil Total cooling capacity (3) kW 10,5 19,5 34,7 59,8 80 127,4 171,3 Sensitive cooling capacity (3) kW 4,1 7,6 13,9 23,9 32 51 68,5 Water flow rate (3) m3/h 1,6 2,9 6 10,3 13,7 21,9 29,5 Water side pressure drop (3) kPa 15 8 7 23 33 34 3,2 For the performance of the H version, contact the head office. Heating Fresh air flow rate equal to the air expulsion flow rate; Outdoor air temperature (in) -5°C 80% r.h.; Room temperature 20°C, 50% r.h. Cooling mode Fresh air flow rate equal to the air expulsion flow rate; Outdoor air temperature (in) 35°C 50% r.h.; Room temperature 26°C, 50% r.h. (1) With nominal air flow rates and useful pressure of 100Pa. (2) Coil water inlet temperature 70°C; Coil inlet-outlet temperature difference 10°C; Coil air intake temperature 15°C; Water pressure drops not included with a 3-way valve (standard). (3) Coil water inlet temperature 7°C; Coil inlet-outlet temperature difference 5°C; Coil air intake temperature 28°C, 75% RH; Water pressure drops not inclusive with a 3-way valve (standard). Sound power level of the flow fan not ducted with useful static pressure equivalent to 0 Pa.
  • 4. Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italia Tel. 0442633111 - Telefax 044293577 www.aermec.com All specifications are subject to change without prior notice. Although every effort has been made to ensure accuracy, Aermec does not assume responsibility or liability for eventual errors or omissions. ERSR 07 09 12 15 17 21 24 Height A mm 965 1285 1445 1765 2085 2405 2725 Width B mm 895 1005 1375 1695 1855 2335 2665 Depth C mm 1375 1535 2045 2365 2365 3005 3005 Weight kg 240 340 570 820 1010 1610 1980 ERSR_Y_UN50_00 Dimensional data (mm) A 120 B C Horizontal installation