Heat recovery unit with enthalpy exchanger
NEW
Features
The following accessories are available for complete control of the TRS recovery units:
Accessories
•	 TRSCP1: Flush control panel with an LCD
display to control the On-Off, speed selection,
programmable weekly timer and the automatic
Free-Cooling functions. IR receiver for coupled
operation with the IR remote control accessory.
	 Wall installation recessed in supplied electrical
junction boxes "module 502".
•	 TRSCPR1: Remote control and flush control
panel with an LCD display to control the On-Off,
speed selection, programmable weekly timer and
the automatic Free-Cooling functions. IR receiver
for coupled operation with the IR remote control
accessory.
	 Wall installation recessed in supplied electrical
junction boxes "module 502".
The TRS heat recovery units allow to join maximum
environmental comfort with sure energy saving.
Forced ventilation must be created in current air
conditioning and treatment plants, which leads
to the expulsion of treated air, determining large
energy consumption and increase in costs.
TRS intends to solve these problems using a static
heat recovery unit that saves most of the energy
that would otherwise be lost.
The unit adopts high-efficiency heat recovery
with countercurrent flows which consists of flat
sheets of special paper that allow you to recover
both sensible and latent heat (humidity).
No condensation forms by adopting the enthalpy
recovery unit: part of the humidity in a flow of air is
absorbed by the porous surface and is then trans-
ferred completely to the opposite air flow. There-
fore, no condensate drip tray or the relative
drain pipe is required. The high static pressures
available allow ducts to be mounted, thereby al-
lowing the extraction or input of air across multiple
environments simultaneously.
• 	 Very compact units that can only be installed
horizontally, which require simple maintenance
of the heat exchanger and filters (both remov-
able from the side).
•	 Automatic free-cooling function.
•	 Free-cooling in mid-season thanks to the auto-
matic by-pass function.
• Centrifugal fans with Brushless EC motor, with
the possibility to adjust the speed on 10 differ-
ent levels through the obligatory accessory
TRSPTS, touch screen control panel
	 In the absence of this accessory it will only be
possible, by acting on the remote on-off con-
tact, to operate the fans always at maximum
speed.
• 	 Built-in electrical panel with electronic board for
the control of ventilation and free-cooling func-
tions.
•	 Hexagonal-shaped enthalpy recovery unit to
increase the exchange surface.
•	 Galvanised sheet metal self-supporting panels
with insulation.
• 	 Air filters, in efficiency class F9 (with G3 prefilter)
on the fresh air, G3 filter on the return flow.
• 	 Pressure switch with integrated dirty filter signal.
•	 Silent operation.
•	 The installation does not require a condensate
drain system.
•	QUICK AND EASY INSTALLATION
•	FANS COUPLED TO BRUSHLESS DC MOTORS WITH
LOW ENERGY CONSUMPTION
TRS
•	 TRSPTS: Control panel with Touch Screen. •	 TRSQSW: Wall CO2 probe. •	 TRSUSW: Wall humidity probe.
Accessories compatibility
TRS 251 351 501 651 801 1001 1301
TRSPTS • • • • • •
TRSQSW • • • • • •
TRSUSW • • • • • •
TRSPTS
Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italia
Tel. 0442633111 - Telefax 044293577
www.aermec.com
All specifications are subject to change without prior notice.
Although every effort has been made to ensure accuracy, Aermec
does not assume responsibility or liability for eventual errors or
omissions.
Technical data
Dimensional data (mm)
TRS_Y_UN50_00
(1) Man = Manual from selector or keyboard;
(2) Sound pressure level assessed at 1m from suction / discharge ports and the inspection side at nominal conditions in free field.
(3) Outdoor air -5 ° C 80% RH; ambient air 20 ° C 50% RH.
(4) Outdoor air: 32 ° C BS, UR 50%; Ambient air: 26 ° C BS, UR 50%
(5) According to EU regulation 1253/2014; at the nominal pressure; temperature and humidity conditions referred to EN308.
TRS 251 351 501 651 801 1001 1301
Air flow rate m3/h 250 350 500 650 800 1000 1300
Nominal static pressure Pa 90 140 110 100 140 140 140
Max input current A 0.5 0.6 0.6 1.2 1.4 2.1 2.7
Fans
Motor type EC
n° speed 10
Ventilation control (1) Man
Internal specific power of SPF int W/(m3/s) 812 670 547 846 865 881 873
Total nominal absorbed power kW 0.08 0.13 0.15 0.23 0.32 0.39 0.50
Sound pressure level (2) dB(A) 34 37 39 40 42 43 44
Heat recovery
Winter thermal efficiency (3) % 73.0 74.0 76.0 74.0 76.0 76.0 74.2
Enthalpy winter efficiency (3) % 65.0 65.0 67.0 65.0 65.0 62.0 59.0
Summer thermal efficiency (4) % 73.0 74.0 76.0 74.0 76.0 76.0 74.0
Summer enthalpy efficiency (4) % 62.0 62.0 63.0 60.0 63.0 60.0 58.0
Dry thermal efficiency (5) % 73.0 74.0 76.0 74.0 76.0 76.0 74.0
Model Dimensions [mm] Weight
[kg]A B C
TRS251 815 270 650 30
TRS351 815 270 855 37
TRS501 895 270 955 43
TRS651 1185 390 945 65
TRS801 1185 390 1200 71
TRS1001 1200 390 1290 83
TRS1301 1200 390 1290 83
Air expelled
Fresh air

More Related Content

PDF
Sc y un50_00
PDF
Wrl hp y-na60_00
PDF
Catalog biến tần Frenic eHVAC - beeteco.com
PDF
G y un50_00
PDF
Crac precision climate_control_units_for_data_centres
PDF
Fuji tu dong hoa catalog frenic-hvac-dienhathe.org
PDF
Sontex Supercal 531 Multifunctional Integrator - Brochure
PPT
Daihan Laboratory Refrigerator
Sc y un50_00
Wrl hp y-na60_00
Catalog biến tần Frenic eHVAC - beeteco.com
G y un50_00
Crac precision climate_control_units_for_data_centres
Fuji tu dong hoa catalog frenic-hvac-dienhathe.org
Sontex Supercal 531 Multifunctional Integrator - Brochure
Daihan Laboratory Refrigerator

What's hot (20)

PPT
Ventilation
PDF
Catalog Biến tần Frenic-HVAC (Fuji Electric)
PPTX
Whynter ARC-12SD Portable Air Conditioner
PDF
AXIS SKU-4 RHI Heat Meter
PPTX
Whynter ARC-110WD Portable Air Conditioner
PPTX
Temperature based-fan-controller
PDF
Sontex Supercal 539 Heat Meter - Spec Sheet
PDF
Sontex Superstatic 449 Static Heat Meter And Cooling Meter - Brochure
PPTX
Siemens Terminal Box Controller (APOGEE Automation System )
PDF
Natural ventilation controls brochure
PDF
Temperature Controlled Fan Project
PPSX
SGS PDWB HIGH STATIC DUCTED AMV PRESENTATION
PPTX
Sonkor fan coil low static ducted pdwl presentation slideshare
PPTX
Innovations - Toshiba 17.02.14
PDF
AXIS SKU-03 Ultrasonic Heating And Cooling Energy Meter
PDF
Sensus Pollucom E Heat Meter - Spec Sheet
PDF
R y un50_00
PPTX
temperature control using 8086 microprocessor by vikas arya
PDF
Heat Meters - Sontex Superstatic 749 - Spec Sheet
DOCX
AUTOMATIC FAN CONTROLLER USING THERMISTOR
Ventilation
Catalog Biến tần Frenic-HVAC (Fuji Electric)
Whynter ARC-12SD Portable Air Conditioner
AXIS SKU-4 RHI Heat Meter
Whynter ARC-110WD Portable Air Conditioner
Temperature based-fan-controller
Sontex Supercal 539 Heat Meter - Spec Sheet
Sontex Superstatic 449 Static Heat Meter And Cooling Meter - Brochure
Siemens Terminal Box Controller (APOGEE Automation System )
Natural ventilation controls brochure
Temperature Controlled Fan Project
SGS PDWB HIGH STATIC DUCTED AMV PRESENTATION
Sonkor fan coil low static ducted pdwl presentation slideshare
Innovations - Toshiba 17.02.14
AXIS SKU-03 Ultrasonic Heating And Cooling Energy Meter
Sensus Pollucom E Heat Meter - Spec Sheet
R y un50_00
temperature control using 8086 microprocessor by vikas arya
Heat Meters - Sontex Superstatic 749 - Spec Sheet
AUTOMATIC FAN CONTROLLER USING THERMISTOR
Ad

Similar to Trs y un50_00 (20)

PDF
Rpf y un50_00
PDF
Urhe cf y-un50_00
PDF
Urhe cf y-un50_00
PDF
P y un50_00
PDF
Komfortecsb200250een
PDF
Rtx 17-23 y-un50_00
PDF
Rittal top therm_chiller
PDF
Frenic hvac catalog
PDF
TIDA-01070-Design-Guide
PDF
Komforteclblbeen
PDF
Komforteclblbeen
PDF
Unico System for Commercial HVAC Promotional Flyer
PDF
Ersr y un50_00
PDF
Mitsubishi inverter freqrol-f700 series dienhathe.vn
PDF
Mitsubishi inverter freqrol-f700 series
PDF
Mitsubishi inverter freqrol-f700 series
PDF
Dekon Rooftop units t3 conditions
PDF
Trane Cube
PDF
Sb ls freecool-screw-inverter_1.2_en
PDF
Carrier Inverter Ducted_tcm175-49778 (1).pdf
Rpf y un50_00
Urhe cf y-un50_00
Urhe cf y-un50_00
P y un50_00
Komfortecsb200250een
Rtx 17-23 y-un50_00
Rittal top therm_chiller
Frenic hvac catalog
TIDA-01070-Design-Guide
Komforteclblbeen
Komforteclblbeen
Unico System for Commercial HVAC Promotional Flyer
Ersr y un50_00
Mitsubishi inverter freqrol-f700 series dienhathe.vn
Mitsubishi inverter freqrol-f700 series
Mitsubishi inverter freqrol-f700 series
Dekon Rooftop units t3 conditions
Trane Cube
Sb ls freecool-screw-inverter_1.2_en
Carrier Inverter Ducted_tcm175-49778 (1).pdf
Ad

More from Oliverh Kalprit (19)

PDF
Tubommzen
PDF
Rte 1 en
PDF
Blsileodesignleaflet201802en
PDF
PDF
Nlc 0280-1250-co y-un50_00
PDF
Bltower svshleaflet201804en
PDF
Mva mono y-un50_00
PDF
Nrp 0800-1800-hp-t y-un50_00
PDF
Vento expert duo_a30_1_wen
PDF
Bavaria100 catalog
PDF
Ta y sa60_00
PDF
Nlc co y-na60_02
PDF
Ank y na60_00
PDF
Ventosolarv60propro2en
PDF
Blturboleaflet201804en
PDF
PDF
Smartiren
PDF
Ventoergoa251proen
PDF
Vento expert a50_1_wen
Tubommzen
Rte 1 en
Blsileodesignleaflet201802en
Nlc 0280-1250-co y-un50_00
Bltower svshleaflet201804en
Mva mono y-un50_00
Nrp 0800-1800-hp-t y-un50_00
Vento expert duo_a30_1_wen
Bavaria100 catalog
Ta y sa60_00
Nlc co y-na60_02
Ank y na60_00
Ventosolarv60propro2en
Blturboleaflet201804en
Smartiren
Ventoergoa251proen
Vento expert a50_1_wen

Recently uploaded (20)

PDF
Human-AI Collaboration: Balancing Agentic AI and Autonomy in Hybrid Systems
PDF
Level 2 – IBM Data and AI Fundamentals (1)_v1.1.PDF
PPTX
AUTOMOTIVE ENGINE MANAGEMENT (MECHATRONICS).pptx
PPTX
tack Data Structure with Array and Linked List Implementation, Push and Pop O...
PDF
UNIT no 1 INTRODUCTION TO DBMS NOTES.pdf
PPTX
Management Information system : MIS-e-Business Systems.pptx
PDF
Abrasive, erosive and cavitation wear.pdf
PPTX
Fundamentals of safety and accident prevention -final (1).pptx
PDF
III.4.1.2_The_Space_Environment.p pdffdf
PDF
Artificial Superintelligence (ASI) Alliance Vision Paper.pdf
PPTX
ASME PCC-02 TRAINING -DESKTOP-NLE5HNP.pptx
PDF
August -2025_Top10 Read_Articles_ijait.pdf
PDF
Accra-Kumasi Expressway - Prefeasibility Report Volume 1 of 7.11.2018.pdf
PPTX
"Array and Linked List in Data Structures with Types, Operations, Implementat...
PPTX
communication and presentation skills 01
PPTX
CyberSecurity Mobile and Wireless Devices
PDF
BIO-INSPIRED ARCHITECTURE FOR PARSIMONIOUS CONVERSATIONAL INTELLIGENCE : THE ...
PPTX
Current and future trends in Computer Vision.pptx
PPT
Total quality management ppt for engineering students
PDF
737-MAX_SRG.pdf student reference guides
Human-AI Collaboration: Balancing Agentic AI and Autonomy in Hybrid Systems
Level 2 – IBM Data and AI Fundamentals (1)_v1.1.PDF
AUTOMOTIVE ENGINE MANAGEMENT (MECHATRONICS).pptx
tack Data Structure with Array and Linked List Implementation, Push and Pop O...
UNIT no 1 INTRODUCTION TO DBMS NOTES.pdf
Management Information system : MIS-e-Business Systems.pptx
Abrasive, erosive and cavitation wear.pdf
Fundamentals of safety and accident prevention -final (1).pptx
III.4.1.2_The_Space_Environment.p pdffdf
Artificial Superintelligence (ASI) Alliance Vision Paper.pdf
ASME PCC-02 TRAINING -DESKTOP-NLE5HNP.pptx
August -2025_Top10 Read_Articles_ijait.pdf
Accra-Kumasi Expressway - Prefeasibility Report Volume 1 of 7.11.2018.pdf
"Array and Linked List in Data Structures with Types, Operations, Implementat...
communication and presentation skills 01
CyberSecurity Mobile and Wireless Devices
BIO-INSPIRED ARCHITECTURE FOR PARSIMONIOUS CONVERSATIONAL INTELLIGENCE : THE ...
Current and future trends in Computer Vision.pptx
Total quality management ppt for engineering students
737-MAX_SRG.pdf student reference guides

Trs y un50_00

  • 1. Heat recovery unit with enthalpy exchanger NEW Features The following accessories are available for complete control of the TRS recovery units: Accessories • TRSCP1: Flush control panel with an LCD display to control the On-Off, speed selection, programmable weekly timer and the automatic Free-Cooling functions. IR receiver for coupled operation with the IR remote control accessory. Wall installation recessed in supplied electrical junction boxes "module 502". • TRSCPR1: Remote control and flush control panel with an LCD display to control the On-Off, speed selection, programmable weekly timer and the automatic Free-Cooling functions. IR receiver for coupled operation with the IR remote control accessory. Wall installation recessed in supplied electrical junction boxes "module 502". The TRS heat recovery units allow to join maximum environmental comfort with sure energy saving. Forced ventilation must be created in current air conditioning and treatment plants, which leads to the expulsion of treated air, determining large energy consumption and increase in costs. TRS intends to solve these problems using a static heat recovery unit that saves most of the energy that would otherwise be lost. The unit adopts high-efficiency heat recovery with countercurrent flows which consists of flat sheets of special paper that allow you to recover both sensible and latent heat (humidity). No condensation forms by adopting the enthalpy recovery unit: part of the humidity in a flow of air is absorbed by the porous surface and is then trans- ferred completely to the opposite air flow. There- fore, no condensate drip tray or the relative drain pipe is required. The high static pressures available allow ducts to be mounted, thereby al- lowing the extraction or input of air across multiple environments simultaneously. • Very compact units that can only be installed horizontally, which require simple maintenance of the heat exchanger and filters (both remov- able from the side). • Automatic free-cooling function. • Free-cooling in mid-season thanks to the auto- matic by-pass function. • Centrifugal fans with Brushless EC motor, with the possibility to adjust the speed on 10 differ- ent levels through the obligatory accessory TRSPTS, touch screen control panel In the absence of this accessory it will only be possible, by acting on the remote on-off con- tact, to operate the fans always at maximum speed. • Built-in electrical panel with electronic board for the control of ventilation and free-cooling func- tions. • Hexagonal-shaped enthalpy recovery unit to increase the exchange surface. • Galvanised sheet metal self-supporting panels with insulation. • Air filters, in efficiency class F9 (with G3 prefilter) on the fresh air, G3 filter on the return flow. • Pressure switch with integrated dirty filter signal. • Silent operation. • The installation does not require a condensate drain system. • QUICK AND EASY INSTALLATION • FANS COUPLED TO BRUSHLESS DC MOTORS WITH LOW ENERGY CONSUMPTION TRS • TRSPTS: Control panel with Touch Screen. • TRSQSW: Wall CO2 probe. • TRSUSW: Wall humidity probe. Accessories compatibility TRS 251 351 501 651 801 1001 1301 TRSPTS • • • • • • TRSQSW • • • • • • TRSUSW • • • • • • TRSPTS
  • 2. Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italia Tel. 0442633111 - Telefax 044293577 www.aermec.com All specifications are subject to change without prior notice. Although every effort has been made to ensure accuracy, Aermec does not assume responsibility or liability for eventual errors or omissions. Technical data Dimensional data (mm) TRS_Y_UN50_00 (1) Man = Manual from selector or keyboard; (2) Sound pressure level assessed at 1m from suction / discharge ports and the inspection side at nominal conditions in free field. (3) Outdoor air -5 ° C 80% RH; ambient air 20 ° C 50% RH. (4) Outdoor air: 32 ° C BS, UR 50%; Ambient air: 26 ° C BS, UR 50% (5) According to EU regulation 1253/2014; at the nominal pressure; temperature and humidity conditions referred to EN308. TRS 251 351 501 651 801 1001 1301 Air flow rate m3/h 250 350 500 650 800 1000 1300 Nominal static pressure Pa 90 140 110 100 140 140 140 Max input current A 0.5 0.6 0.6 1.2 1.4 2.1 2.7 Fans Motor type EC n° speed 10 Ventilation control (1) Man Internal specific power of SPF int W/(m3/s) 812 670 547 846 865 881 873 Total nominal absorbed power kW 0.08 0.13 0.15 0.23 0.32 0.39 0.50 Sound pressure level (2) dB(A) 34 37 39 40 42 43 44 Heat recovery Winter thermal efficiency (3) % 73.0 74.0 76.0 74.0 76.0 76.0 74.2 Enthalpy winter efficiency (3) % 65.0 65.0 67.0 65.0 65.0 62.0 59.0 Summer thermal efficiency (4) % 73.0 74.0 76.0 74.0 76.0 76.0 74.0 Summer enthalpy efficiency (4) % 62.0 62.0 63.0 60.0 63.0 60.0 58.0 Dry thermal efficiency (5) % 73.0 74.0 76.0 74.0 76.0 76.0 74.0 Model Dimensions [mm] Weight [kg]A B C TRS251 815 270 650 30 TRS351 815 270 855 37 TRS501 895 270 955 43 TRS651 1185 390 945 65 TRS801 1185 390 1200 71 TRS1001 1200 390 1290 83 TRS1301 1200 390 1290 83 Air expelled Fresh air