How to use Time-Domain Reflectometer (TDR)
I’m no electrical engineer, (the closest experience I have with electricity is the amount of
electrocution I received when I was a child [due to faulty cabling of electrical appliances])
so I will spare readers technical jargons and boring formulas because this guide is not
aimed to be published in the International Journal of Mumbo-Jumbo. This guide is to
help anyone how to confidently use the TDR feature when troubleshooting basic
Layer 1 Ethernet issue.
My knowledge with this feature is based entirely on experience and a lot of trial-and-error.
What is Time-Domain Reflectometer (TDR)?
“A time-domain reflectometer (TDR) is an electronic instrument used to characterize and
locate faults in metallic cables (for example, twisted wire pairs, coaxial cables) 1.”

For the sake of this document, “TDR testing” and “TDR” are used interchangeably to sow
confusion to the un-initiated. They both mean the same.

How can TDR help me?
TDR, in its simplest form, can help you determine IF you have a cable problem, WHICH
pair(s) is/are faulty and HOW FAR away the fault is.
Typically, when you have a Layer 1 issue there are a lot of factors to consider:
1 Local-end Side (LeS) patch cable;
2 Local-end Side (LeS) patch panel (including punch block);
3 Horizontal cable;
4 Remote-end (Red) patch panel (including punch block);
5 Remote-end (Red) patch cable; and
6 Remote-end (Red) device NIC
So you see, dear readers, TDR minimize the guess-work.
Picture this …
Before we begin, let me give you the “lay of the land”. Presume the following scenario:

1
What model of Cisco switch does TDR work on?
Firstly, not all switch model support TDR. TDR feature first came out with the Catalyst
2960. So here is the list of which ones will work and will not:

Model

TDR Support

2960

Yes1, 2

2960G

Yes

2960S

Yes

2918

Unknown

2350

Unknown

2360

Unknown

2975

Unknown

3560

No

3560G

Yes

3560E/3560X Yes
3750

No

3750G

Yes

3750E/3750X Yes
Nexus 2K

Unknown

Nexus 5K

Unknown

Nexus 7K

Yes3

Sup7E/X4548 Yes
Note:
2
1 The 2960 will support TDR in both the FastEthernet and dual-personality
GigiabitEthernet port, however, when used on a FastEthernet port, TDR will only test the
first two pairs, namely Pairs A & B. For obvious reasons, Pairs C and D will not be tested
when used on non-GigabitEthernet ports.
2.
Except the WS-C2960-48PDL, when using the copper GigabitEthernet port of the
Catalyst 2960, one must manually set the interface to copper using the command “media
rj” before the test can be conducted.
3.

Confirmed by Cisco TAC, Ankur Garg.

The list does not include modules/blades for the Catalyst 4000/4500, 5000/5500,
6000/6500 although it is mentioned here that TDR was introduced with IOS Release 12.2
ZY for the Catalyst 6000/6500. It’s not included in the list above because I don’t have the
resources to test and verify.
Legacy Cisco Catalyst models 1900, 2900XL/3500XL, 2940/2950/2955, 2948G and 2970
are not supported. Routers are also not supported. I do not have any resources to test
router Ethernet Switch Modules (NME, HWIC, EHWIC). Wireless Access Points do not
support TDR.
Why doesn’t the FastEthernet-flavoured 3560 and 3750 support TDR and but the
cheaper FastEthernet 2960 support TDR?
Base on the time-line, the “plain” (or non-GigabitEthernet copper port) 3560 and 3750
came out BEFORE the 2960. The “chip” for the TDR was included in the design of the
2960. When Cisco released the 3560G and 3750G later, someone made the ultimate
decision to include the TDR feature as a standard. Therefore, the plain 3560 and 3750
are the only two series that WON’T HAVE the TDR feature. (Take note reader: Emphasis
on the words “WON’T HAVE”).

•

Any Gotchas I need to be aware of?
Switches need to run IOS version 12.2 or later. TDR is supported in IOS version
15.0. IOS version 12.0 and 12.1 do NOT support TDR.

•

If you are running IOS version 12.2(46)SE or earlier, TDR test is DISRUPTIVE.
During the test, the interface will go down and up. For obvious reasons, anything
connected will lose network connectivity.

•

If the remote-end device is a power-over-ethernet (PoE) device, the test will
cause the device to lose power. If you have, for example, a Voice over IP (VoIP) phone
and a PC client is connected to the phone, both the phone and client will lose network
3
connectivity because the phone does not have a bypass functionality. This will affect ALL
IOS versions.
•

Particularly when you are running old IOS versions, the test can take between
five (5) to seven (7) seconds.

•

TDR works on 10/100/1000BaseTx. Fibre optic ports (any flavours) is not
covered/discussed here. TenGigabitEthernet copper port DOES NOT (YET) support
TDR.

•

Cisco GLC-T/GLC-TX SFP module does NOT support TDR.
The next two Gotcha items are for those who plan to use the TDR feature on Cisco
Catalyst 2960 and 2960G (2960S not included):

•

1. The 2960 will support TDR in both the FastEthernet and dual-personality
GigiabitEthernet port, however, when used on a FastEthernet port, TDR will only test the
first two pairs, namely Pairs A & B. For obvious reasons, Pairs C and D will not be tested
when used on non-GigabitEthernet ports. Pairs C and D will report a result of “Not
Supported”.

•

2. Except the WS-C2960-48PDL, when using the copper GigabitEthernet (Gig 0/1
and Gig 0/2) ports of the Catalyst 2960, one must manually set the interface to copper
using the command “media rj” before the test can be conducted.
How to use TDR?
The commands are very simple: One to start the test and the second command to
display the result. Here is simple procedure:
1 Command to start the TDR: “test cable tdr interface <interface of your choice>”;
2 Wait for about 5 to 7 seconds for the test to run; and
3Command to show the result of the TDR test: “show cable tdr interface <interface of
your choice>”
See? Easy! Now let’s see what the I results would look like.
Interface

Speed

Local pair

Pair length

Remote pair

Pair status

Gi0/1

1000M

Pair A

3 +/- 1 meters

Pair A

Normal

Pair B

3 +/- 1 meters

Pair B

Normal

Pair C

3 +/- 1 meters

Pair C

Normal

Pair D

3 +/- 1 meters

Pair D

Normal

4
So what does this result above tell us?
1 Port tested is on GigabitEthernet 0/1;
2 Port has negotiated to 1 Gbps;
3 Cable use is a straight-through cable (look and compare the values of “Local pair” and
“remote pair”);
1Cable length is approximately 3 metres long and an error (length-wise) of 1 metre; and
2 All four pairs are working fine (Pair status)
Under “Pair status” you can get the following results:
Result

Explaination

Normal

Ideal result you want.
If testing FastEthernet, you want Pair A and B as “Normal”.
If testing GigabitEthernet, you want ALL as “Normal”.

Open

Open circuit. This means that one (or more) pair has “no pin contact”.

Short

Short circuit.

Impedance
Mismatched

Bad cable. For more explanation, go here.

An ideal result is “Normal”. In practice, whether the remote-end device is FastEthernet or
GigabitEthernet, I will never accept a TDR result other than “Normal” in all four
pairs.
Cable Pairs explained?
This is how I see what each Pairs control:
Pairs

Function

A

This pair controls whether or not the port should go up or down.

B

Protocol-level and controls FastEthernet.

C

Power over Ethernet (PoE)

D

GigabitEthernet

More examples
Interface

Speed

Local pair Pair length

Remote pair

Pair status

Gi0/11

100M

Pair A

13 +/- 1 meters

Pair B

Normal

Pair B

12 +/- 1 meters

Pair A

Normal

Pair C

0 +/- 1 meters

Pair D

Open

Pair D

0 +/- 1 meters

Pair C

Open

5
Normally, this result would freak me out. Look at the items in RED. Pairs C and D are
reporting a cable value of “0”. Next I move to the “Pair status” and it’s reported as an
Open circuit. No pin contact. Whao! But look at the speed. It’s 100 Mbps. So it’s normal
… I guess.
But wait. What if the remote-end side (Red) client is a GigabitEthernet. So where is the
faulty cabling? Which one of the patch cables? Or is it a horizontal cabling? Does the
client support GigabitEthernet or not?
Here’s another clue: Look at the length of the cable for Pair A and B. It’s reporting around
12 to 13 metres. Experience has taught me that my Local-end Side (LeS) cable doesn’t
exceed two metres. So that rules out my cable, however the horizontal cabling is more
than 10 metres. So what’s between the horizontal cabling and the remote-end client? You
have three suspects: 1) The remote-end punch block; 2) the remote-end patch cable; and
3) remote-end client.
Culprit was the remote-end punch block and the horizontal cabling: Cable contractors
only terminated two pairs.
Never ask a boy to do a man’s job!
Interface

Speed

Local pair

Pair length

Remote pair

Pair status

Gi1/0/48

auto

Pair A

149 +/- 1 meters

Pair B

Normal

Pair B

151 +/- 1 meters

Pair A

Normal

Pair C

35 +/- 1 meters

Pair D

Short/Impedance Mism

Pair D

21 +/- 1 meters

Pair C

Short/Impedance Mism

Its results like the ones above that makes me want to cry.
Ok, I look under “Pair status” and I see “Short/Impedance Mism” for Pair C and D. No
question about it. It’s bad cabling. This is not what makes me want to cry. Look at under
“Pair length” of Pair A and B. NOW cry.
Should I be worried?
Interface

Speed

Local pair

Pair length

Remote pair

Pair status

Fa0/39

100M

Pair A

6 +/- 1 meters

N/A

Open

Pair B

49 +/- 1 meters

N/A

Open

Pair C

N/A

N/A

Not Supported

Pair D

N/A

N/A

Not Supported

6
Looking at the result, I can confidently say that the appliance was a 48-port Cisco
Catalyst 2960. How? Look under “Interface”. Look at “Pair status” for Pair C and D. Only
the plain 2960 FastEthernet ports can support TDR.
But look at “Pair status” for Pairs A and B. What does that mean?

It means that the remote-end (Red) patch cable is missing.

Weird things have happened before
I’ve taken the opportunity to do limited testing on TDR on a 4510R+E. The chassis has a
Sup7E and with a X4548-RJ45V+ line card (IOS version 03.01.01.SG). The result(s) are
very, very weird. Oh, by the way, the TDR testing on this setup takes 60 seconds. 60
seconds! Good grief! I have no idea whether the Sup7E or the line card is the factor.
The sample below is coming from a GOOD cable:
Interface

Speed

Local pair

Pair length

Remote pair

Pair status

Gi2/36

1Gbps

1-2

29 +/-10m

Unknown

Fault

3-6

30 +/-10m

Unknown

Fault

4-5

29 +/-10m

Unknown

Fault

7-8

30 +/-10m

Unknown

Fault

7
And the sample below is coming from a BAD cable:
Interface

Speed

Local pair

Pair length

Remote pair

Pair status

Gi2/37

0Mbps

1-2

56 +/-10m

Unknown

Fault

3-6

0m

Unknown

Fault

4-5

56 +/-10m

Unknown

Fault

7-8

59 +/-10m

Unknown

Fault

As you can see, whether or not you have a good or a bad cable the result from the
“Remote pair” and “Status” can be deceiving. The ONLY WAY to determine if you have a
bad cable issue or not is to look at the “Speed” and the output to the “Pair length”.
I am suspecting that the misleading result of the “Remote pair” and the “Pair status” is an
IOS bug.

More related:
How To Recover Cisco Router Password
The Difference of The Cisco Catalyst 2900 and Cisco Catalyst 1900
More Cisco products and Reviews you can visit: http://www.3anetwork.com/blog

3Anetwork.com is a world leading Cisco networking products wholesaler, we wholesale
original new Cisco networking equipments, including Cisco Catalyst switches, Cisco
routers, Cisco firewalls, Cisco wireless products, Cisco modules and interface cards
products at competitive price and ship to worldwide.
Our website: http://www.3anetwork.com
Telephone: +852-3069-7733
Email: info@3Anetwork.com
Address: 23/F Lucky Plaza, 315-321 Lockhart Road, Wanchai, Hongkong

8

More Related Content

PPTX
Andrew L4TDF-PSA
PPTX
Andrew L4TDF-PS
PPTX
Andrew L6PDF-RPC
PDF
Kurth Electronic Short Catalog
PPTX
Andrew L7PDF-RPC
PPTX
Andrew L4DR-PS
PDF
Megger Cable Fault Locators - Power Cable Fault Locators, Van mountable Solut...
PDF
Webinar Slides: Measurements and Analysis for Switched-mode Power Designs
Andrew L4TDF-PSA
Andrew L4TDF-PS
Andrew L6PDF-RPC
Kurth Electronic Short Catalog
Andrew L7PDF-RPC
Andrew L4DR-PS
Megger Cable Fault Locators - Power Cable Fault Locators, Van mountable Solut...
Webinar Slides: Measurements and Analysis for Switched-mode Power Designs

What's hot (6)

PPTX
Andrew L4PDR-C
PDF
7.3.2.6 lab build and test network cables
PDF
PPTX
Overview of life testing in Minitab
PDF
Cable Detection Tools - Cable Detection Tools - Cable Detection EZICAT
PPTX
Andrew L7TNF-PS
Andrew L4PDR-C
7.3.2.6 lab build and test network cables
Overview of life testing in Minitab
Cable Detection Tools - Cable Detection Tools - Cable Detection EZICAT
Andrew L7TNF-PS
Ad

Similar to How to use time domain reflectometer (tdr) (20)

PPT
E2020 TDR CATV Training
PPT
E2020 TDR Telco Training
PDF
6912402.pdf jgygg jhghuhg jhyygg jgghgfhg
PPT
E2020 General Step TDR Training
PDF
IRJET- Arduino based Single Phase Fault Detection System using IoT
PDF
Computer Networking Lab File
PDF
How to Use the CertiFiber® Pro to Test Installed Corning Multimode Pretium ED...
PPTX
Understanding the Instrument Transmitter TEST Connection.pptx
PPT
Nd at s best practices for single mode tier i ii testing 01-2011
PDF
How to Use the DTX-MFM2 Fiber Modules to Test Installed Corning Multimode Pre...
PDF
How to Use the DTX-EFM2 Fiber Modules to Test Installed Corning Multimode Pre...
PDF
Des 1024 d manual_en_de
PDF
Capacitance Type Level Transmitter for liquids.pdf
PDF
Fadal Part General Information - Maintenance Manual
PDF
Fadal Part General Information - Maintenance Manual
PPTX
OTDR HSV600 User Training.pptx
PDF
PDF
96000707 gas-turbine-control
PPTX
Pinpoint the leading causes of downtime with LinkIQ Cable and Network Tester
E2020 TDR CATV Training
E2020 TDR Telco Training
6912402.pdf jgygg jhghuhg jhyygg jgghgfhg
E2020 General Step TDR Training
IRJET- Arduino based Single Phase Fault Detection System using IoT
Computer Networking Lab File
How to Use the CertiFiber® Pro to Test Installed Corning Multimode Pretium ED...
Understanding the Instrument Transmitter TEST Connection.pptx
Nd at s best practices for single mode tier i ii testing 01-2011
How to Use the DTX-MFM2 Fiber Modules to Test Installed Corning Multimode Pre...
How to Use the DTX-EFM2 Fiber Modules to Test Installed Corning Multimode Pre...
Des 1024 d manual_en_de
Capacitance Type Level Transmitter for liquids.pdf
Fadal Part General Information - Maintenance Manual
Fadal Part General Information - Maintenance Manual
OTDR HSV600 User Training.pptx
96000707 gas-turbine-control
Pinpoint the leading causes of downtime with LinkIQ Cable and Network Tester
Ad

More from 3Anetwork com (20)

DOC
Cisco sfp modules
DOC
Cisco 3900 and cisco 2900 series routers
DOC
Cisco catalyst 2960 x series
DOC
Cisco catalyst 3750 x series switches
DOC
Cisco switches for small business
DOC
How to recover the password for cisco 2900 integrated services router
DOC
Cisco 4 and 8-port gigabit ethernet ehwi cs
DOC
Configuring the cisco switch with the cli based setup program
DOC
Cisco 2960 basic configuration – vlan configuration
DOC
Configuring a Cisco Router as a PPPoE Client for DSL Connectivity
DOC
Cisco catalyst 3850 series switches datasheet
DOC
Cisco catalyst 2960 series switches overview
DOC
Enterprise Network Manager: the Router-On-A-stick
DOC
Cisco Catalyst 2960-X Datasheet
DOC
How to configure a catalyst 3750 x
DOC
Hubs vs switches vs routers
DOC
Installing and removing sfp and sfp+ transceiver modules
DOC
Dmvpn with configuration example
DOC
Cisco unified access from vision to reality
DOC
Cisco router command configuration overview
Cisco sfp modules
Cisco 3900 and cisco 2900 series routers
Cisco catalyst 2960 x series
Cisco catalyst 3750 x series switches
Cisco switches for small business
How to recover the password for cisco 2900 integrated services router
Cisco 4 and 8-port gigabit ethernet ehwi cs
Configuring the cisco switch with the cli based setup program
Cisco 2960 basic configuration – vlan configuration
Configuring a Cisco Router as a PPPoE Client for DSL Connectivity
Cisco catalyst 3850 series switches datasheet
Cisco catalyst 2960 series switches overview
Enterprise Network Manager: the Router-On-A-stick
Cisco Catalyst 2960-X Datasheet
How to configure a catalyst 3750 x
Hubs vs switches vs routers
Installing and removing sfp and sfp+ transceiver modules
Dmvpn with configuration example
Cisco unified access from vision to reality
Cisco router command configuration overview

Recently uploaded (20)

PPTX
Big Data Technologies - Introduction.pptx
PPTX
Spectroscopy.pptx food analysis technology
PDF
Network Security Unit 5.pdf for BCA BBA.
PPTX
Effective Security Operations Center (SOC) A Modern, Strategic, and Threat-In...
PDF
How UI/UX Design Impacts User Retention in Mobile Apps.pdf
PDF
Approach and Philosophy of On baking technology
PDF
Reach Out and Touch Someone: Haptics and Empathic Computing
PPTX
Understanding_Digital_Forensics_Presentation.pptx
PPT
“AI and Expert System Decision Support & Business Intelligence Systems”
PDF
Encapsulation_ Review paper, used for researhc scholars
PPTX
20250228 LYD VKU AI Blended-Learning.pptx
PDF
Electronic commerce courselecture one. Pdf
PDF
Profit Center Accounting in SAP S/4HANA, S4F28 Col11
PDF
KodekX | Application Modernization Development
PDF
Blue Purple Modern Animated Computer Science Presentation.pdf.pdf
PDF
Machine learning based COVID-19 study performance prediction
PPTX
Programs and apps: productivity, graphics, security and other tools
PDF
Building Integrated photovoltaic BIPV_UPV.pdf
PDF
Dropbox Q2 2025 Financial Results & Investor Presentation
PDF
Unlocking AI with Model Context Protocol (MCP)
Big Data Technologies - Introduction.pptx
Spectroscopy.pptx food analysis technology
Network Security Unit 5.pdf for BCA BBA.
Effective Security Operations Center (SOC) A Modern, Strategic, and Threat-In...
How UI/UX Design Impacts User Retention in Mobile Apps.pdf
Approach and Philosophy of On baking technology
Reach Out and Touch Someone: Haptics and Empathic Computing
Understanding_Digital_Forensics_Presentation.pptx
“AI and Expert System Decision Support & Business Intelligence Systems”
Encapsulation_ Review paper, used for researhc scholars
20250228 LYD VKU AI Blended-Learning.pptx
Electronic commerce courselecture one. Pdf
Profit Center Accounting in SAP S/4HANA, S4F28 Col11
KodekX | Application Modernization Development
Blue Purple Modern Animated Computer Science Presentation.pdf.pdf
Machine learning based COVID-19 study performance prediction
Programs and apps: productivity, graphics, security and other tools
Building Integrated photovoltaic BIPV_UPV.pdf
Dropbox Q2 2025 Financial Results & Investor Presentation
Unlocking AI with Model Context Protocol (MCP)

How to use time domain reflectometer (tdr)

  • 1. How to use Time-Domain Reflectometer (TDR) I’m no electrical engineer, (the closest experience I have with electricity is the amount of electrocution I received when I was a child [due to faulty cabling of electrical appliances]) so I will spare readers technical jargons and boring formulas because this guide is not aimed to be published in the International Journal of Mumbo-Jumbo. This guide is to help anyone how to confidently use the TDR feature when troubleshooting basic Layer 1 Ethernet issue. My knowledge with this feature is based entirely on experience and a lot of trial-and-error. What is Time-Domain Reflectometer (TDR)? “A time-domain reflectometer (TDR) is an electronic instrument used to characterize and locate faults in metallic cables (for example, twisted wire pairs, coaxial cables) 1.” For the sake of this document, “TDR testing” and “TDR” are used interchangeably to sow confusion to the un-initiated. They both mean the same. How can TDR help me? TDR, in its simplest form, can help you determine IF you have a cable problem, WHICH pair(s) is/are faulty and HOW FAR away the fault is. Typically, when you have a Layer 1 issue there are a lot of factors to consider: 1 Local-end Side (LeS) patch cable; 2 Local-end Side (LeS) patch panel (including punch block); 3 Horizontal cable; 4 Remote-end (Red) patch panel (including punch block); 5 Remote-end (Red) patch cable; and 6 Remote-end (Red) device NIC So you see, dear readers, TDR minimize the guess-work. Picture this … Before we begin, let me give you the “lay of the land”. Presume the following scenario: 1
  • 2. What model of Cisco switch does TDR work on? Firstly, not all switch model support TDR. TDR feature first came out with the Catalyst 2960. So here is the list of which ones will work and will not: Model TDR Support 2960 Yes1, 2 2960G Yes 2960S Yes 2918 Unknown 2350 Unknown 2360 Unknown 2975 Unknown 3560 No 3560G Yes 3560E/3560X Yes 3750 No 3750G Yes 3750E/3750X Yes Nexus 2K Unknown Nexus 5K Unknown Nexus 7K Yes3 Sup7E/X4548 Yes Note: 2
  • 3. 1 The 2960 will support TDR in both the FastEthernet and dual-personality GigiabitEthernet port, however, when used on a FastEthernet port, TDR will only test the first two pairs, namely Pairs A & B. For obvious reasons, Pairs C and D will not be tested when used on non-GigabitEthernet ports. 2. Except the WS-C2960-48PDL, when using the copper GigabitEthernet port of the Catalyst 2960, one must manually set the interface to copper using the command “media rj” before the test can be conducted. 3. Confirmed by Cisco TAC, Ankur Garg. The list does not include modules/blades for the Catalyst 4000/4500, 5000/5500, 6000/6500 although it is mentioned here that TDR was introduced with IOS Release 12.2 ZY for the Catalyst 6000/6500. It’s not included in the list above because I don’t have the resources to test and verify. Legacy Cisco Catalyst models 1900, 2900XL/3500XL, 2940/2950/2955, 2948G and 2970 are not supported. Routers are also not supported. I do not have any resources to test router Ethernet Switch Modules (NME, HWIC, EHWIC). Wireless Access Points do not support TDR. Why doesn’t the FastEthernet-flavoured 3560 and 3750 support TDR and but the cheaper FastEthernet 2960 support TDR? Base on the time-line, the “plain” (or non-GigabitEthernet copper port) 3560 and 3750 came out BEFORE the 2960. The “chip” for the TDR was included in the design of the 2960. When Cisco released the 3560G and 3750G later, someone made the ultimate decision to include the TDR feature as a standard. Therefore, the plain 3560 and 3750 are the only two series that WON’T HAVE the TDR feature. (Take note reader: Emphasis on the words “WON’T HAVE”). • Any Gotchas I need to be aware of? Switches need to run IOS version 12.2 or later. TDR is supported in IOS version 15.0. IOS version 12.0 and 12.1 do NOT support TDR. • If you are running IOS version 12.2(46)SE or earlier, TDR test is DISRUPTIVE. During the test, the interface will go down and up. For obvious reasons, anything connected will lose network connectivity. • If the remote-end device is a power-over-ethernet (PoE) device, the test will cause the device to lose power. If you have, for example, a Voice over IP (VoIP) phone and a PC client is connected to the phone, both the phone and client will lose network 3
  • 4. connectivity because the phone does not have a bypass functionality. This will affect ALL IOS versions. • Particularly when you are running old IOS versions, the test can take between five (5) to seven (7) seconds. • TDR works on 10/100/1000BaseTx. Fibre optic ports (any flavours) is not covered/discussed here. TenGigabitEthernet copper port DOES NOT (YET) support TDR. • Cisco GLC-T/GLC-TX SFP module does NOT support TDR. The next two Gotcha items are for those who plan to use the TDR feature on Cisco Catalyst 2960 and 2960G (2960S not included): • 1. The 2960 will support TDR in both the FastEthernet and dual-personality GigiabitEthernet port, however, when used on a FastEthernet port, TDR will only test the first two pairs, namely Pairs A & B. For obvious reasons, Pairs C and D will not be tested when used on non-GigabitEthernet ports. Pairs C and D will report a result of “Not Supported”. • 2. Except the WS-C2960-48PDL, when using the copper GigabitEthernet (Gig 0/1 and Gig 0/2) ports of the Catalyst 2960, one must manually set the interface to copper using the command “media rj” before the test can be conducted. How to use TDR? The commands are very simple: One to start the test and the second command to display the result. Here is simple procedure: 1 Command to start the TDR: “test cable tdr interface <interface of your choice>”; 2 Wait for about 5 to 7 seconds for the test to run; and 3Command to show the result of the TDR test: “show cable tdr interface <interface of your choice>” See? Easy! Now let’s see what the I results would look like. Interface Speed Local pair Pair length Remote pair Pair status Gi0/1 1000M Pair A 3 +/- 1 meters Pair A Normal Pair B 3 +/- 1 meters Pair B Normal Pair C 3 +/- 1 meters Pair C Normal Pair D 3 +/- 1 meters Pair D Normal 4
  • 5. So what does this result above tell us? 1 Port tested is on GigabitEthernet 0/1; 2 Port has negotiated to 1 Gbps; 3 Cable use is a straight-through cable (look and compare the values of “Local pair” and “remote pair”); 1Cable length is approximately 3 metres long and an error (length-wise) of 1 metre; and 2 All four pairs are working fine (Pair status) Under “Pair status” you can get the following results: Result Explaination Normal Ideal result you want. If testing FastEthernet, you want Pair A and B as “Normal”. If testing GigabitEthernet, you want ALL as “Normal”. Open Open circuit. This means that one (or more) pair has “no pin contact”. Short Short circuit. Impedance Mismatched Bad cable. For more explanation, go here. An ideal result is “Normal”. In practice, whether the remote-end device is FastEthernet or GigabitEthernet, I will never accept a TDR result other than “Normal” in all four pairs. Cable Pairs explained? This is how I see what each Pairs control: Pairs Function A This pair controls whether or not the port should go up or down. B Protocol-level and controls FastEthernet. C Power over Ethernet (PoE) D GigabitEthernet More examples Interface Speed Local pair Pair length Remote pair Pair status Gi0/11 100M Pair A 13 +/- 1 meters Pair B Normal Pair B 12 +/- 1 meters Pair A Normal Pair C 0 +/- 1 meters Pair D Open Pair D 0 +/- 1 meters Pair C Open 5
  • 6. Normally, this result would freak me out. Look at the items in RED. Pairs C and D are reporting a cable value of “0”. Next I move to the “Pair status” and it’s reported as an Open circuit. No pin contact. Whao! But look at the speed. It’s 100 Mbps. So it’s normal … I guess. But wait. What if the remote-end side (Red) client is a GigabitEthernet. So where is the faulty cabling? Which one of the patch cables? Or is it a horizontal cabling? Does the client support GigabitEthernet or not? Here’s another clue: Look at the length of the cable for Pair A and B. It’s reporting around 12 to 13 metres. Experience has taught me that my Local-end Side (LeS) cable doesn’t exceed two metres. So that rules out my cable, however the horizontal cabling is more than 10 metres. So what’s between the horizontal cabling and the remote-end client? You have three suspects: 1) The remote-end punch block; 2) the remote-end patch cable; and 3) remote-end client. Culprit was the remote-end punch block and the horizontal cabling: Cable contractors only terminated two pairs. Never ask a boy to do a man’s job! Interface Speed Local pair Pair length Remote pair Pair status Gi1/0/48 auto Pair A 149 +/- 1 meters Pair B Normal Pair B 151 +/- 1 meters Pair A Normal Pair C 35 +/- 1 meters Pair D Short/Impedance Mism Pair D 21 +/- 1 meters Pair C Short/Impedance Mism Its results like the ones above that makes me want to cry. Ok, I look under “Pair status” and I see “Short/Impedance Mism” for Pair C and D. No question about it. It’s bad cabling. This is not what makes me want to cry. Look at under “Pair length” of Pair A and B. NOW cry. Should I be worried? Interface Speed Local pair Pair length Remote pair Pair status Fa0/39 100M Pair A 6 +/- 1 meters N/A Open Pair B 49 +/- 1 meters N/A Open Pair C N/A N/A Not Supported Pair D N/A N/A Not Supported 6
  • 7. Looking at the result, I can confidently say that the appliance was a 48-port Cisco Catalyst 2960. How? Look under “Interface”. Look at “Pair status” for Pair C and D. Only the plain 2960 FastEthernet ports can support TDR. But look at “Pair status” for Pairs A and B. What does that mean? It means that the remote-end (Red) patch cable is missing. Weird things have happened before I’ve taken the opportunity to do limited testing on TDR on a 4510R+E. The chassis has a Sup7E and with a X4548-RJ45V+ line card (IOS version 03.01.01.SG). The result(s) are very, very weird. Oh, by the way, the TDR testing on this setup takes 60 seconds. 60 seconds! Good grief! I have no idea whether the Sup7E or the line card is the factor. The sample below is coming from a GOOD cable: Interface Speed Local pair Pair length Remote pair Pair status Gi2/36 1Gbps 1-2 29 +/-10m Unknown Fault 3-6 30 +/-10m Unknown Fault 4-5 29 +/-10m Unknown Fault 7-8 30 +/-10m Unknown Fault 7
  • 8. And the sample below is coming from a BAD cable: Interface Speed Local pair Pair length Remote pair Pair status Gi2/37 0Mbps 1-2 56 +/-10m Unknown Fault 3-6 0m Unknown Fault 4-5 56 +/-10m Unknown Fault 7-8 59 +/-10m Unknown Fault As you can see, whether or not you have a good or a bad cable the result from the “Remote pair” and “Status” can be deceiving. The ONLY WAY to determine if you have a bad cable issue or not is to look at the “Speed” and the output to the “Pair length”. I am suspecting that the misleading result of the “Remote pair” and the “Pair status” is an IOS bug. More related: How To Recover Cisco Router Password The Difference of The Cisco Catalyst 2900 and Cisco Catalyst 1900 More Cisco products and Reviews you can visit: http://www.3anetwork.com/blog 3Anetwork.com is a world leading Cisco networking products wholesaler, we wholesale original new Cisco networking equipments, including Cisco Catalyst switches, Cisco routers, Cisco firewalls, Cisco wireless products, Cisco modules and interface cards products at competitive price and ship to worldwide. Our website: http://www.3anetwork.com Telephone: +852-3069-7733 Email: info@3Anetwork.com Address: 23/F Lucky Plaza, 315-321 Lockhart Road, Wanchai, Hongkong 8