SlideShare a Scribd company logo
HPE Security ArcSight Model Import
Connector for RepSM Plus
Software Version: 7.3.0.7954.0
Configuration Guide
November 7, 2016
Legal Notices
Warranty
The only warranties for Hewlett Packard Enterprise products and services are set forth in the express warranty statements
accompanying such products and services. Nothing herein should be construed as constituting an additional warranty.
Hewlett Packard Enterprise shall not be liable for technical or editorial errors or omissions contained herein.
The information contained herein is subject to change without notice.
The network information used in the examples in this document (including IP addresses and hostnames) is for illustration
purposes only.
HPE Security ArcSight products are highly flexible and function as you configure them. The accessibility, integrity, and
confidentiality of your data is your responsibility. Implement a comprehensive security strategy and follow good security
practices.
This document is confidential.
Restricted Rights Legend
Confidential computer software. Valid license from Hewlett Packard Enterprise required for possession, use or copying.
Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical
Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license.
Copyright Notice
© Copyright 2016 Hewlett Packard Enterprise Development, LP
Follow this link to see a complete statement of copyrights and acknowledgements:
https://www.protect724.hpe.com/docs/DOC-13026
Support
Phone Alistof phone numbers is available on the HPE Security ArcSightTechnical Support
Page: https://softwaresupport.hpe.com/documents/10180/14684/esp-support-
contact-list
Support Web Site https://softwaresupport.hpe.com
Protect 724 Community https://www.protect724.hpe.com
Contact Information
Configuration Guide
HPE Model Import Connector for RepSM Plus 7.3.0.7954.0 Page 2 of 11
Contents
Model Import Connector for RepSM Plus 4
Features and Functional Summary 4
Installing the Connector 5
Model Import Connector Installation 5
Running Connectors 7
Connector Upgrade 8
Administrative Tasks - RepSM Plus Configuration Using the ArcSight Console 8
Setting up the Model Import User in ESM 8
Starting and Stopping Data Import 9
Optional - Reloading RepSM Plus Data 9
Optional - Optimization of Data Transfer Using a Timer 9
Send Documentation Feedback 11
HPE Model Import Connector for RepSM Plus 7.3.0.7954.0 Page 3 of 11
Model Import Connector for RepSM Plus
This guide describes installing the Model Import Connector for HPE Security ArcSight Reputation
Security Monitor Plus (RepSM Plus) and configuring the device for data collection.
The HPE RepSM Plus solution uses internet reputation data to provide a list of known bad or harmful
domains of IP addresses to provide context to security events. The Model Import Connector for RepSM
Plus is a component of RepSM Plus which retrieves reputation data from the RepSM Plus threat
intelligence service , processes this data, and forwards it to ArcSight ESM.
The threat intelligence includes reputation information about internet nodes which are known to exhibit
bad behavior. The ill reputed nodes are identified by their network address or Domain Name System
(DNS) name. This data is used by the accompanying RepSM Plus content package to detect malware
infected machines, zero day attacks, and dangerous browsing. The user can also use the data to
implement custom ESM solutions. For further details on this solution, see the HPE Reputation Security
Monitor Solution Guide.
Features and Functional Summary
The Model Import Connector for RepSM Plus retrieves the reputation data and forwards it to ESM. This
connector supports one ESM destination.
The connector only sends the delta information from the last retrieved data to the ESM.
These entries are:
l IPv4 addresses
l Host and domain names
For each entry these reputation attributes are retrieved:
l Reputation Score
l Exploit Type
The initial import happens when the connector is started for the first time and the initial import
command is issued from the ESM console. Following the initial load of the entries, the connector checks
for updates, by default, every two hours. With the data from this query, the connector will process the
deltas to add or delete the entries or update the threat scores as required and sends this information to
the ESM.
HPE Model Import Connector for RepSM Plus 7.3.0.7954.0 Page 4 of 11
Installing the Connector
Before installing the connector, verify that ESM (the product with which the connector will
communicate) and Console have already been installed correctly. It is recommended that the connector
not be installed on the same machine as ESM. Also, be sure the following are available:
l Additional 2GB memory if the connector is run in standalone mode.
l Local administrator access to the machine on which the connector will be installed.
l The machine, on which the connector will be installed, has external access over the Internet to any
system over port 443 and connectivity to the ESM machine over port 8443 (default) or the
configured port if the default was not used.
l ESM IP address, port, administrator user name, and password.
Note: When installing the model import connector as a service (and as a non-root user), run this
command:
$ARCSIGHT_HOME/current/bin/arcsight agentsvc -i -u user -sn <service_name>
Model Import Connector Installation
This section provides instructions on how to install the Model Import Connector for RepSM Plus.
Note: Use a non-root account to install the Model Import Connector for RepSM Plus.
To install the Model Import Connector for RepSM Plus:
1. Download the Model Import Connector for RepSM Plus installation executable using the link
provided in the e-mail sent to you by HPE.
2. Start the connector installer by running the executable.
Note: The Model Import Connector for RepSM Plus installation requires additional steps after
the installation wizard has finished. See step 16 of this procedure and subsequent steps for
details.
Follow the installation wizard through the following folder selection tasks and installation of the
core connector software:
l Introduction
l Choose Install Folder
l Choose Shortcut Folder
Configuration Guide
Model Import Connector for RepSM Plus
HPE Model Import Connector for RepSM Plus 7.3.0.7954.0 Page 5 of 11
l Pre-Installation Summary
l Installing...
3. Select Add a Connector.
4. Model Import Connector for RepSM Plus is already selected. Click Next.
5. Enter the required parameters to configure the connector, then click Next.
Parameter Description
Proxy Host
(https)
Use this field and the following three fields only if you need the connector to use a proxy to access
the Internet. Enter the proxy host IP address. This value is required for proxy configuration.
Proxy Port Enter the proxy port. This value is required for proxy configuration.
Proxy User
Name
Enter the proxy user name. This value is needed if the proxy requires authentication. If you specify a
proxy user name, you must also specify a proxy password.
Proxy
Password
Enter the password for the proxy user specified. This value is needed if the proxy requires
authentication. This field is required only if you have specified a proxy user name.
6. ArcSight Manager (encrypted) is selected. Click Next.
7. Enter destination parameters, including the host and port information, and click Next.
Parameter Description
Manager Host
Name
Enter the name or IP address of the host on which the Manager is installed.
Manager Port Enter the network port from which the Manager is accepting requests. The default port is 8443.
User Name Enter a valid ArcSight user name to log in to configure the SmartConnector. This is the same
user name you created during the Manager installation.
Password Enter a valid ArcSight password to log in to configure the SmartConnector. This is the same
password you created during the Manager installation.
AUP Master
Destination
Select true or false.
Filter Out All
Events
Select true or false.
Enable Demo
CA
Select true or false.
8. Enter a Name for the connector and provide other information identifying the connector's use in
your environment. Click Next.
9. Select whether to import a certificate.
10. Review the Add connector Summary and click Next. If the summary is incorrect, click Previous to
make changes.
11. The wizard now prompts you to choose whether you want to run the connector as a stand-alone
process or as a service. Choose either Install as a service or Leave as a standalone application.
Configuration Guide
Model Import Connector for RepSM Plus
HPE Model Import Connector for RepSM Plus 7.3.0.7954.0 Page 6 of 11
Click Next.
12. To close the installation wizard, choose Exit and click Next. There are further installation steps
after you close the wizard. Be sure to continue with the subsequent installation steps.
13. If the connector is run in standalone mode, the default heap size is 256MB. For proper operation of
the connector, HPE recommends that you modify the heap size setting to 2GB. There is no need to
modify memory if the connector is run as a service; if the connector is configured to run as a service,
the heap size is set to 2GB by default.
Increase the memory for the connector by doing the following (in the following example
commands, ARCSIGHT_HOME represents the name of the directory where the connector is
installed):
l For Linux - create the following shell script and be sure it is executable: ~/ARCSIGHT_
HOME/current/user/agent/setmem.sh
with the following content:
ARCSIGHT_MEMORY_OPTIONS=" -Xms1024m -Xmx2048m "
l For Windows - create the following batch file: $ARCSIGHT_
HOMEcurrentuseragentsetmem.bat
with the following content:
SET ARCSIGHT_MEMORY_OPTIONS=" -Xms1024m -Xmx2048m "
Be sure to use regular double quote characters in the file content in either the shell script or the
batch file.
14. Verify that the connector is running. You can check the ArcSight Console Navigator in the
Resources tab, under Connectors. If the connector is running, you will see <connector_name>
(running) listed. See "Running Connectors" below.
15. Set up the Model Import user in ESM. See "Setting up the Model Import User in ESM" on the next
page.
16. Start the data import. See "Starting and Stopping Data Import" on page 9.
Running Connectors
Connectors can be installed and run in standalone mode, on Windows platforms as a Windows service,
or on UNIX platforms as a UNIX daemon, depending upon the platform supported. On Windows
platforms, connectors also can be run using shortcuts and optional Start menu entries.
If installed standalone, the connector must be started manually, and is not automatically active when a
host is restarted. If installed as a service or daemon, the connector runs automatically when the host is
restarted. For information about connectors running as services or daemons, see the ArcSight
SmartConnector User's Guide, Chapter 3, Installing SmartConnectors, in the section “Running
SmartConnectors”.
Configuration Guide
Model Import Connector for RepSM Plus
HPE Model Import Connector for RepSM Plus 7.3.0.7954.0 Page 7 of 11
For connectors installed standalone, to run all installed connectors on a particular host, open a
command window, go to $ARCSIGHT_HOMEcurrentbin and run: ./arcsight agents
To view the connector log, read the file:
For Windows - $ARCSIGHT_HOMEcurrentlogsagent.log
For Linux - ~/ARCSIGHT_HOME/current/logs/agent.log
To stop all connectors, enter Ctrl+C in the command window.
Connector Upgrade
To upgrade the Model Import Connector for RepSM Plus, you must uninstall the current version of the
connector and then install the latest version. For information about uninstalling connectors, see the
ArcSight SmartConnector User's Guide.
Administrative Tasks - RepSM Plus Configuration
Using the ArcSight Console
There are mandatory and optional administrative tasks. "Setting up the Model Import User in ESM"
below and "Starting and Stopping Data Import" on the next page are mandatory steps for connector
installation, and are mentioned as part of the installation procedure. See "Installing the Connector" on
page 5 for details. You might also find that you need to perform these tasks outside of the context of
the installation procedure.
The tasks "Optional - Reloading RepSM Plus Data" on the next page and "Optional - Optimization of
Data Transfer Using a Timer" on the next page can be performed as needed.
Setting up the Model Import User in ESM
After installing, configuring, and starting the connector, from the ArcSight Console set the Model
Import User for the connector (this must be a user with Console administrative privileges). Setting the
user links the user to the assets, and that user is then treated as the “creator” of the assets. The
connector is then run on that user’s behalf.
1. From the ArcSight Console, go to the Navigator panel and choose the Resources tab.
2. Under Resources, choose the Connectors resource.
3. Under All Connectors, navigate to your Model Import Connector for RepSM Plus.
4. Right click on the connector and select Configure.
5. On the Inspect/Edit panel, choose the Connector tab.
6. Under the Connector tab, go to Model Import User and select a user from the Administrators
group.
Configuration Guide
Model Import Connector for RepSM Plus
HPE Model Import Connector for RepSM Plus 7.3.0.7954.0 Page 8 of 11
7. Click OK.
Note: If a user that does not have administrator privileges is used, the import will fail.
Starting and Stopping Data Import
By default the connector’s data import capability is not started. You must start the import manually in
the ArcSight Console.
Note: Data import needs to be started only once from the ArcSight Console. Unless it is stopped
from the ArcSight Console, there is no need to restart the data import.
To start and stop import for the Model Import Connector for RepSM Plus:
1. Select the Model Import Connector for RepSM Plus and right-click.
2. Select Send Command > Model Import Connector > Start or Stop.
Optional - Reloading RepSM Plus Data
To reload RepSM Plus data:
1. If active, stop the connector.
2. Remove all files at:
Linux - ~/ARCSIGHT_HOME/current/user/agent/agentdata
Windows - $ARCSIGHT_HOMEcurrentuseragentagentdata
3. Remove all folders and XML files (if any) at:
Linux - ~/ARCSIGHT_HOME/current/user/agent/mic/repsm
Windows - $ARCSIGHT_HOMEcurrentuseragentmicrepsm
4. At the ArcSight Console, clear all entries in the Malicious Domains and Malicious IP Addresses
Active Lists. For each Active List:
a. Under Reputation Security Monitor, select the Malicious Domains and/or the Malicious IP
Addresses Active List and right-click.
b. Select Clear Entries.
5. Restart the connector.
Optional - Optimization of Data Transfer Using a Timer
The time interval between archives sent by the connector to ESM can be controlled by the
buildmodeldelay property. The default value is 1 minute.
Configuration Guide
Model Import Connector for RepSM Plus
HPE Model Import Connector for RepSM Plus 7.3.0.7954.0 Page 9 of 11
To increase or decrease this time interval, you can add the buildmodeldelay property to the file
agent.properties (located at $ARCSIGHT_HOMEcurrentuseragent). The property
buildmodeldelay is expressed in milliseconds.
For example, the following property sets the time interval to 10 seconds:
agent.component[35].buildmodeldelay=10000
Configuration Guide
Model Import Connector for RepSM Plus
HPE Model Import Connector for RepSM Plus 7.3.0.7954.0 Page 10 of 11
Send Documentation Feedback
If you have comments about this document, you can contact the documentation team by email. If an
email client is configured on this system, click the link above and an email window opens with the
following information in the subject line:
Feedback on Configuration Guide (Model Import Connector for RepSM Plus 7.3.0.7954.0)
Just add your feedback to the email and click send.
If no email client is available, copy the information above to a new message in a web mail client, and send
your feedback to arc-doc@hpe.com.
We appreciate your feedback!
HPE Model Import Connector for RepSM Plus 7.3.0.7954.0 Page 11 of 11

More Related Content

PDF
HPE ArcSight RepSM Plus 1.6 Solution Guide
PDF
Reputation Security Monitor (RepSM) v1.01 Solution Guide for ArcSight Express...
PDF
ArcSight Model Import Connector for RepSM 7.1.7.7607.0 Configuration guide
PDF
HPE ArcSight RepSM Plus Model Import Connector Release Notes
PDF
Reputation Security Monitor (RepSM) v1.01 Release Notes for ArcSight Express ...
PDF
ArcSight ArcSight Model Import Connector for RepSM 7.1.7.7607.0 Release Notes
PDF
RepSM Model Import Connector v5.2.7.6581.0 Configuration Guide for ArcSight E...
PDF
Installation Guide for ESM 6.8c
HPE ArcSight RepSM Plus 1.6 Solution Guide
Reputation Security Monitor (RepSM) v1.01 Solution Guide for ArcSight Express...
ArcSight Model Import Connector for RepSM 7.1.7.7607.0 Configuration guide
HPE ArcSight RepSM Plus Model Import Connector Release Notes
Reputation Security Monitor (RepSM) v1.01 Release Notes for ArcSight Express ...
ArcSight ArcSight Model Import Connector for RepSM 7.1.7.7607.0 Release Notes
RepSM Model Import Connector v5.2.7.6581.0 Configuration Guide for ArcSight E...
Installation Guide for ESM 6.8c

What's hot (20)

PDF
Upgrade ESM Express License to ESM 6.11.0
PDF
Upgrade Guide for ESM 6.8c
PDF
Anomalous Traffic Detection Security Use Case Guide
PDF
Suspicious Outbound Traffic Monitoring Security Use Case Guide
PDF
ESM_Express_InstallGuide_6.9.0.pdf
PDF
VPN Monitoring Security Use Case Guide version 1.1
PDF
ESM 6.9.1c Patch 3 Release Notes
PDF
Paloalto Networks ACE
PDF
Esm rel notes_6.8cp4
PDF
ESM 6.9.1c Patch 2 Release Notes
PDF
B7500 (G8) Upgrade to RHEL 6.8 (ESM 6.9.1c P2)
PDF
Upgrading from ESM 5.0 SP2 or 5.2 to ESM 5.5
PDF
ESM_UpgradingTo5.6.pdf
PDF
ArcSight Logger Forwarding Connector for HP Operations Manager
PDF
Logger Forwarding Connector for HPE OMi Configuration Guide 7.1.7.7610.0
PDF
HPE InfoSight for 3PAR quickstart shortened v1
PDF
Release Notes for ArcSight Express v4.0
PDF
Cas 003-q&amp;a-demo-exam area
PDF
Logger Forwarding Connector for OMi 7.3.0.7839.0 Release Notes
ODP
OS Security Hardening for SAP HANA
Upgrade ESM Express License to ESM 6.11.0
Upgrade Guide for ESM 6.8c
Anomalous Traffic Detection Security Use Case Guide
Suspicious Outbound Traffic Monitoring Security Use Case Guide
ESM_Express_InstallGuide_6.9.0.pdf
VPN Monitoring Security Use Case Guide version 1.1
ESM 6.9.1c Patch 3 Release Notes
Paloalto Networks ACE
Esm rel notes_6.8cp4
ESM 6.9.1c Patch 2 Release Notes
B7500 (G8) Upgrade to RHEL 6.8 (ESM 6.9.1c P2)
Upgrading from ESM 5.0 SP2 or 5.2 to ESM 5.5
ESM_UpgradingTo5.6.pdf
ArcSight Logger Forwarding Connector for HP Operations Manager
Logger Forwarding Connector for HPE OMi Configuration Guide 7.1.7.7610.0
HPE InfoSight for 3PAR quickstart shortened v1
Release Notes for ArcSight Express v4.0
Cas 003-q&amp;a-demo-exam area
Logger Forwarding Connector for OMi 7.3.0.7839.0 Release Notes
OS Security Hardening for SAP HANA
Ad

Similar to HPE ArcSight RepSM Plus Model Import Connector Config Guide (20)

PDF
HPE ArcSight RepSM Plus 1.6 Release Notes
PDF
ESM 6.9.1c Patch1 Release Notes
PDF
Logger Forwarding Connector for OM 7.3.0.7838.0 Configuration Guide
PDF
Logger Forwarding Connector for OMi 7.3.0.7839.0 Configuration Guide
PDF
Esm 6.0c appliance_config_guide_e7400
PDF
ESM for Azure 6.9.1 Setup Guide
PDF
ESM High Availability Module User's Guide
PDF
ArcSight Actor Model Import Connector for Microsoft Active Directory Configur...
PDF
Forwarding Connector Release Notes for version 6.0.4.6830.0
PDF
ESM 6.5 Patch 1 Release Notes
PDF
Logger Forwarding Connector for NNMi 7.3.0.7837.0 Release Notes
PDF
Logger Forwarding Connector for NNMi 7.3.0.7837.0 Configuration Guide
PDF
ESM Asset Model FlexConnector Developer's Guide for ESM 6.8c
PDF
ArcSight Logger Forwarding Connector for HP NNMi 5.2.3.6287.0 Configuration G...
PDF
ArcMC 2.5.1 Release Notes
PDF
Model Import Connector for RepSM Release Notes
PDF
SafePeak Installation guide
PDF
ESM 6.8 HA OS Upgrade from RHEL 6.5, 6.6, or 6.7 t..
PDF
HP ArcSight Logger Forwarding Connector for HP NNMI Configuration Guide 5.2.1...
PDF
ArcMC for Azure 2.2 Setup Guide
HPE ArcSight RepSM Plus 1.6 Release Notes
ESM 6.9.1c Patch1 Release Notes
Logger Forwarding Connector for OM 7.3.0.7838.0 Configuration Guide
Logger Forwarding Connector for OMi 7.3.0.7839.0 Configuration Guide
Esm 6.0c appliance_config_guide_e7400
ESM for Azure 6.9.1 Setup Guide
ESM High Availability Module User's Guide
ArcSight Actor Model Import Connector for Microsoft Active Directory Configur...
Forwarding Connector Release Notes for version 6.0.4.6830.0
ESM 6.5 Patch 1 Release Notes
Logger Forwarding Connector for NNMi 7.3.0.7837.0 Release Notes
Logger Forwarding Connector for NNMi 7.3.0.7837.0 Configuration Guide
ESM Asset Model FlexConnector Developer's Guide for ESM 6.8c
ArcSight Logger Forwarding Connector for HP NNMi 5.2.3.6287.0 Configuration G...
ArcMC 2.5.1 Release Notes
Model Import Connector for RepSM Release Notes
SafePeak Installation guide
ESM 6.8 HA OS Upgrade from RHEL 6.5, 6.6, or 6.7 t..
HP ArcSight Logger Forwarding Connector for HP NNMI Configuration Guide 5.2.1...
ArcMC for Azure 2.2 Setup Guide
Ad

More from protect724rkeer (15)

PDF
Actor Model Import Connector for Microsoft Active Directory
PDF
Actor Model Import Connector for Microsoft Active Directory Release Notes
PDF
Actor Model Import FlexConnector for Database
PDF
Actor Model Import FlexConnector for Database Release Notes
PDF
CIP for PCI 4.0 Solution Guide for ArcSight Logger
PDF
CIP for PCI 4.0 Release Notes for ArcSight Logger
PDF
CIP IT Governance 5.0 Solution Guide for ArcSight Logger
PDF
CIP IT Governance 5.0 Release Notes for ArcSight Logger
PDF
Logger Brute Force Attack Detection Security Use Case User's Guide
PDF
Logger NERC CIP 1.0 Solutions Guide
PDF
Logger HIPAA CIP 1.0 Solutions Guide
PDF
Logger NERC CIP 1.0 Release Notes
PDF
Logger HIPAA CIP 1.0 Release Notes
PDF
NERC v6.0 for ESM Release Notes
PDF
NERC v6.0 for ESM Solution Guide
Actor Model Import Connector for Microsoft Active Directory
Actor Model Import Connector for Microsoft Active Directory Release Notes
Actor Model Import FlexConnector for Database
Actor Model Import FlexConnector for Database Release Notes
CIP for PCI 4.0 Solution Guide for ArcSight Logger
CIP for PCI 4.0 Release Notes for ArcSight Logger
CIP IT Governance 5.0 Solution Guide for ArcSight Logger
CIP IT Governance 5.0 Release Notes for ArcSight Logger
Logger Brute Force Attack Detection Security Use Case User's Guide
Logger NERC CIP 1.0 Solutions Guide
Logger HIPAA CIP 1.0 Solutions Guide
Logger NERC CIP 1.0 Release Notes
Logger HIPAA CIP 1.0 Release Notes
NERC v6.0 for ESM Release Notes
NERC v6.0 for ESM Solution Guide

Recently uploaded (20)

PDF
How Creative Agencies Leverage Project Management Software.pdf
PDF
Navsoft: AI-Powered Business Solutions & Custom Software Development
PPTX
Introduction to Artificial Intelligence
PPTX
Operating system designcfffgfgggggggvggggggggg
PDF
Why TechBuilder is the Future of Pickup and Delivery App Development (1).pdf
PDF
Design an Analysis of Algorithms II-SECS-1021-03
PDF
Design an Analysis of Algorithms I-SECS-1021-03
PDF
top salesforce developer skills in 2025.pdf
PDF
Nekopoi APK 2025 free lastest update
PDF
2025 Textile ERP Trends: SAP, Odoo & Oracle
PDF
Adobe Illustrator 28.6 Crack My Vision of Vector Design
PDF
Understanding Forklifts - TECH EHS Solution
PDF
System and Network Administraation Chapter 3
PPTX
Odoo POS Development Services by CandidRoot Solutions
PPTX
Oracle E-Business Suite: A Comprehensive Guide for Modern Enterprises
PDF
medical staffing services at VALiNTRY
PPTX
Lecture 3: Operating Systems Introduction to Computer Hardware Systems
PPTX
Essential Infomation Tech presentation.pptx
PDF
How to Choose the Right IT Partner for Your Business in Malaysia
PPTX
ai tools demonstartion for schools and inter college
How Creative Agencies Leverage Project Management Software.pdf
Navsoft: AI-Powered Business Solutions & Custom Software Development
Introduction to Artificial Intelligence
Operating system designcfffgfgggggggvggggggggg
Why TechBuilder is the Future of Pickup and Delivery App Development (1).pdf
Design an Analysis of Algorithms II-SECS-1021-03
Design an Analysis of Algorithms I-SECS-1021-03
top salesforce developer skills in 2025.pdf
Nekopoi APK 2025 free lastest update
2025 Textile ERP Trends: SAP, Odoo & Oracle
Adobe Illustrator 28.6 Crack My Vision of Vector Design
Understanding Forklifts - TECH EHS Solution
System and Network Administraation Chapter 3
Odoo POS Development Services by CandidRoot Solutions
Oracle E-Business Suite: A Comprehensive Guide for Modern Enterprises
medical staffing services at VALiNTRY
Lecture 3: Operating Systems Introduction to Computer Hardware Systems
Essential Infomation Tech presentation.pptx
How to Choose the Right IT Partner for Your Business in Malaysia
ai tools demonstartion for schools and inter college

HPE ArcSight RepSM Plus Model Import Connector Config Guide

  • 1. HPE Security ArcSight Model Import Connector for RepSM Plus Software Version: 7.3.0.7954.0 Configuration Guide November 7, 2016
  • 2. Legal Notices Warranty The only warranties for Hewlett Packard Enterprise products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. Hewlett Packard Enterprise shall not be liable for technical or editorial errors or omissions contained herein. The information contained herein is subject to change without notice. The network information used in the examples in this document (including IP addresses and hostnames) is for illustration purposes only. HPE Security ArcSight products are highly flexible and function as you configure them. The accessibility, integrity, and confidentiality of your data is your responsibility. Implement a comprehensive security strategy and follow good security practices. This document is confidential. Restricted Rights Legend Confidential computer software. Valid license from Hewlett Packard Enterprise required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license. Copyright Notice © Copyright 2016 Hewlett Packard Enterprise Development, LP Follow this link to see a complete statement of copyrights and acknowledgements: https://www.protect724.hpe.com/docs/DOC-13026 Support Phone Alistof phone numbers is available on the HPE Security ArcSightTechnical Support Page: https://softwaresupport.hpe.com/documents/10180/14684/esp-support- contact-list Support Web Site https://softwaresupport.hpe.com Protect 724 Community https://www.protect724.hpe.com Contact Information Configuration Guide HPE Model Import Connector for RepSM Plus 7.3.0.7954.0 Page 2 of 11
  • 3. Contents Model Import Connector for RepSM Plus 4 Features and Functional Summary 4 Installing the Connector 5 Model Import Connector Installation 5 Running Connectors 7 Connector Upgrade 8 Administrative Tasks - RepSM Plus Configuration Using the ArcSight Console 8 Setting up the Model Import User in ESM 8 Starting and Stopping Data Import 9 Optional - Reloading RepSM Plus Data 9 Optional - Optimization of Data Transfer Using a Timer 9 Send Documentation Feedback 11 HPE Model Import Connector for RepSM Plus 7.3.0.7954.0 Page 3 of 11
  • 4. Model Import Connector for RepSM Plus This guide describes installing the Model Import Connector for HPE Security ArcSight Reputation Security Monitor Plus (RepSM Plus) and configuring the device for data collection. The HPE RepSM Plus solution uses internet reputation data to provide a list of known bad or harmful domains of IP addresses to provide context to security events. The Model Import Connector for RepSM Plus is a component of RepSM Plus which retrieves reputation data from the RepSM Plus threat intelligence service , processes this data, and forwards it to ArcSight ESM. The threat intelligence includes reputation information about internet nodes which are known to exhibit bad behavior. The ill reputed nodes are identified by their network address or Domain Name System (DNS) name. This data is used by the accompanying RepSM Plus content package to detect malware infected machines, zero day attacks, and dangerous browsing. The user can also use the data to implement custom ESM solutions. For further details on this solution, see the HPE Reputation Security Monitor Solution Guide. Features and Functional Summary The Model Import Connector for RepSM Plus retrieves the reputation data and forwards it to ESM. This connector supports one ESM destination. The connector only sends the delta information from the last retrieved data to the ESM. These entries are: l IPv4 addresses l Host and domain names For each entry these reputation attributes are retrieved: l Reputation Score l Exploit Type The initial import happens when the connector is started for the first time and the initial import command is issued from the ESM console. Following the initial load of the entries, the connector checks for updates, by default, every two hours. With the data from this query, the connector will process the deltas to add or delete the entries or update the threat scores as required and sends this information to the ESM. HPE Model Import Connector for RepSM Plus 7.3.0.7954.0 Page 4 of 11
  • 5. Installing the Connector Before installing the connector, verify that ESM (the product with which the connector will communicate) and Console have already been installed correctly. It is recommended that the connector not be installed on the same machine as ESM. Also, be sure the following are available: l Additional 2GB memory if the connector is run in standalone mode. l Local administrator access to the machine on which the connector will be installed. l The machine, on which the connector will be installed, has external access over the Internet to any system over port 443 and connectivity to the ESM machine over port 8443 (default) or the configured port if the default was not used. l ESM IP address, port, administrator user name, and password. Note: When installing the model import connector as a service (and as a non-root user), run this command: $ARCSIGHT_HOME/current/bin/arcsight agentsvc -i -u user -sn <service_name> Model Import Connector Installation This section provides instructions on how to install the Model Import Connector for RepSM Plus. Note: Use a non-root account to install the Model Import Connector for RepSM Plus. To install the Model Import Connector for RepSM Plus: 1. Download the Model Import Connector for RepSM Plus installation executable using the link provided in the e-mail sent to you by HPE. 2. Start the connector installer by running the executable. Note: The Model Import Connector for RepSM Plus installation requires additional steps after the installation wizard has finished. See step 16 of this procedure and subsequent steps for details. Follow the installation wizard through the following folder selection tasks and installation of the core connector software: l Introduction l Choose Install Folder l Choose Shortcut Folder Configuration Guide Model Import Connector for RepSM Plus HPE Model Import Connector for RepSM Plus 7.3.0.7954.0 Page 5 of 11
  • 6. l Pre-Installation Summary l Installing... 3. Select Add a Connector. 4. Model Import Connector for RepSM Plus is already selected. Click Next. 5. Enter the required parameters to configure the connector, then click Next. Parameter Description Proxy Host (https) Use this field and the following three fields only if you need the connector to use a proxy to access the Internet. Enter the proxy host IP address. This value is required for proxy configuration. Proxy Port Enter the proxy port. This value is required for proxy configuration. Proxy User Name Enter the proxy user name. This value is needed if the proxy requires authentication. If you specify a proxy user name, you must also specify a proxy password. Proxy Password Enter the password for the proxy user specified. This value is needed if the proxy requires authentication. This field is required only if you have specified a proxy user name. 6. ArcSight Manager (encrypted) is selected. Click Next. 7. Enter destination parameters, including the host and port information, and click Next. Parameter Description Manager Host Name Enter the name or IP address of the host on which the Manager is installed. Manager Port Enter the network port from which the Manager is accepting requests. The default port is 8443. User Name Enter a valid ArcSight user name to log in to configure the SmartConnector. This is the same user name you created during the Manager installation. Password Enter a valid ArcSight password to log in to configure the SmartConnector. This is the same password you created during the Manager installation. AUP Master Destination Select true or false. Filter Out All Events Select true or false. Enable Demo CA Select true or false. 8. Enter a Name for the connector and provide other information identifying the connector's use in your environment. Click Next. 9. Select whether to import a certificate. 10. Review the Add connector Summary and click Next. If the summary is incorrect, click Previous to make changes. 11. The wizard now prompts you to choose whether you want to run the connector as a stand-alone process or as a service. Choose either Install as a service or Leave as a standalone application. Configuration Guide Model Import Connector for RepSM Plus HPE Model Import Connector for RepSM Plus 7.3.0.7954.0 Page 6 of 11
  • 7. Click Next. 12. To close the installation wizard, choose Exit and click Next. There are further installation steps after you close the wizard. Be sure to continue with the subsequent installation steps. 13. If the connector is run in standalone mode, the default heap size is 256MB. For proper operation of the connector, HPE recommends that you modify the heap size setting to 2GB. There is no need to modify memory if the connector is run as a service; if the connector is configured to run as a service, the heap size is set to 2GB by default. Increase the memory for the connector by doing the following (in the following example commands, ARCSIGHT_HOME represents the name of the directory where the connector is installed): l For Linux - create the following shell script and be sure it is executable: ~/ARCSIGHT_ HOME/current/user/agent/setmem.sh with the following content: ARCSIGHT_MEMORY_OPTIONS=" -Xms1024m -Xmx2048m " l For Windows - create the following batch file: $ARCSIGHT_ HOMEcurrentuseragentsetmem.bat with the following content: SET ARCSIGHT_MEMORY_OPTIONS=" -Xms1024m -Xmx2048m " Be sure to use regular double quote characters in the file content in either the shell script or the batch file. 14. Verify that the connector is running. You can check the ArcSight Console Navigator in the Resources tab, under Connectors. If the connector is running, you will see <connector_name> (running) listed. See "Running Connectors" below. 15. Set up the Model Import user in ESM. See "Setting up the Model Import User in ESM" on the next page. 16. Start the data import. See "Starting and Stopping Data Import" on page 9. Running Connectors Connectors can be installed and run in standalone mode, on Windows platforms as a Windows service, or on UNIX platforms as a UNIX daemon, depending upon the platform supported. On Windows platforms, connectors also can be run using shortcuts and optional Start menu entries. If installed standalone, the connector must be started manually, and is not automatically active when a host is restarted. If installed as a service or daemon, the connector runs automatically when the host is restarted. For information about connectors running as services or daemons, see the ArcSight SmartConnector User's Guide, Chapter 3, Installing SmartConnectors, in the section “Running SmartConnectors”. Configuration Guide Model Import Connector for RepSM Plus HPE Model Import Connector for RepSM Plus 7.3.0.7954.0 Page 7 of 11
  • 8. For connectors installed standalone, to run all installed connectors on a particular host, open a command window, go to $ARCSIGHT_HOMEcurrentbin and run: ./arcsight agents To view the connector log, read the file: For Windows - $ARCSIGHT_HOMEcurrentlogsagent.log For Linux - ~/ARCSIGHT_HOME/current/logs/agent.log To stop all connectors, enter Ctrl+C in the command window. Connector Upgrade To upgrade the Model Import Connector for RepSM Plus, you must uninstall the current version of the connector and then install the latest version. For information about uninstalling connectors, see the ArcSight SmartConnector User's Guide. Administrative Tasks - RepSM Plus Configuration Using the ArcSight Console There are mandatory and optional administrative tasks. "Setting up the Model Import User in ESM" below and "Starting and Stopping Data Import" on the next page are mandatory steps for connector installation, and are mentioned as part of the installation procedure. See "Installing the Connector" on page 5 for details. You might also find that you need to perform these tasks outside of the context of the installation procedure. The tasks "Optional - Reloading RepSM Plus Data" on the next page and "Optional - Optimization of Data Transfer Using a Timer" on the next page can be performed as needed. Setting up the Model Import User in ESM After installing, configuring, and starting the connector, from the ArcSight Console set the Model Import User for the connector (this must be a user with Console administrative privileges). Setting the user links the user to the assets, and that user is then treated as the “creator” of the assets. The connector is then run on that user’s behalf. 1. From the ArcSight Console, go to the Navigator panel and choose the Resources tab. 2. Under Resources, choose the Connectors resource. 3. Under All Connectors, navigate to your Model Import Connector for RepSM Plus. 4. Right click on the connector and select Configure. 5. On the Inspect/Edit panel, choose the Connector tab. 6. Under the Connector tab, go to Model Import User and select a user from the Administrators group. Configuration Guide Model Import Connector for RepSM Plus HPE Model Import Connector for RepSM Plus 7.3.0.7954.0 Page 8 of 11
  • 9. 7. Click OK. Note: If a user that does not have administrator privileges is used, the import will fail. Starting and Stopping Data Import By default the connector’s data import capability is not started. You must start the import manually in the ArcSight Console. Note: Data import needs to be started only once from the ArcSight Console. Unless it is stopped from the ArcSight Console, there is no need to restart the data import. To start and stop import for the Model Import Connector for RepSM Plus: 1. Select the Model Import Connector for RepSM Plus and right-click. 2. Select Send Command > Model Import Connector > Start or Stop. Optional - Reloading RepSM Plus Data To reload RepSM Plus data: 1. If active, stop the connector. 2. Remove all files at: Linux - ~/ARCSIGHT_HOME/current/user/agent/agentdata Windows - $ARCSIGHT_HOMEcurrentuseragentagentdata 3. Remove all folders and XML files (if any) at: Linux - ~/ARCSIGHT_HOME/current/user/agent/mic/repsm Windows - $ARCSIGHT_HOMEcurrentuseragentmicrepsm 4. At the ArcSight Console, clear all entries in the Malicious Domains and Malicious IP Addresses Active Lists. For each Active List: a. Under Reputation Security Monitor, select the Malicious Domains and/or the Malicious IP Addresses Active List and right-click. b. Select Clear Entries. 5. Restart the connector. Optional - Optimization of Data Transfer Using a Timer The time interval between archives sent by the connector to ESM can be controlled by the buildmodeldelay property. The default value is 1 minute. Configuration Guide Model Import Connector for RepSM Plus HPE Model Import Connector for RepSM Plus 7.3.0.7954.0 Page 9 of 11
  • 10. To increase or decrease this time interval, you can add the buildmodeldelay property to the file agent.properties (located at $ARCSIGHT_HOMEcurrentuseragent). The property buildmodeldelay is expressed in milliseconds. For example, the following property sets the time interval to 10 seconds: agent.component[35].buildmodeldelay=10000 Configuration Guide Model Import Connector for RepSM Plus HPE Model Import Connector for RepSM Plus 7.3.0.7954.0 Page 10 of 11
  • 11. Send Documentation Feedback If you have comments about this document, you can contact the documentation team by email. If an email client is configured on this system, click the link above and an email window opens with the following information in the subject line: Feedback on Configuration Guide (Model Import Connector for RepSM Plus 7.3.0.7954.0) Just add your feedback to the email and click send. If no email client is available, copy the information above to a new message in a web mail client, and send your feedback to arc-doc@hpe.com. We appreciate your feedback! HPE Model Import Connector for RepSM Plus 7.3.0.7954.0 Page 11 of 11