2
Most read
4
Most read
Huminator II
Precision Humidity Generator
Testo Industrial Services – More assurance, better service.
www.testotis.com
All advantages at a glance
Easy operation, fast regulation, good stability and homogeneity
ü	Fast stabilisation time (e.g. 3 min from 35%RH to 80%RH 	
	 at 25°C)
ü	Highest measuring stability due to optimal insulation of the 	
	 chamber and high-end sealing adapter plate
ü	Large measuring chamber (Ø 160 mm, depth 320 mm)
ü	No condensation inside the measuring chamber through a 	
	 regulation along the dew point
ü	Guaranteed mobility- the compact size and the minimal 	
	 weight ensure an extremely flexible use of the Huminator II.
ü	Wide temperature and humidity range from 5°C to 50°C 	
	 and from 5%RH to 95%RH
ü	New touch display enables a fast and intuitive operation
ü	Graphical and tabular view as well as storage and
	 evaluation of measured values
ü	Integrated, easily accessible and replaceable reference 	
	 sensor, that eliminates the need for an external reference 	
	system
ü	Possibility to program measuring points and procedures 	
	individually
humidity
control
temperature
control
measuring chamber
reference and control probe
(temperature + humidity)
peltier
element
(heat ex-
changer)
+/-°C
+%rH
-%rH
set points/
actual values
touch display
(entry of set points,
indication of actual values)
humidifier
drying
(e. g. silica gel)
Testo
6681
Precise humidity calibrations
The Huminator II offers the possibility to perform a rapid and
easy humidity calibration of measuring instruments, sensors
and data loggers of all manufacturers. The supplied adapter
plate enables a calibration of up to five sensors at a time- wi-
thout deterioration of the homogeneity. Thus, a high level of
efficiency is guaranteed.
The timely programming function allows a large degree of auto-
mation of calibrations since up to 10 humidity and temperature
values can be retrieved automatically one after another. The
stabilization time can be selected freely.
With the help of a Peltier- element, the integrated temperature
regulation generates and stabilizes temperatures in a range
from 5°C to 50°C. Relative humidity can rapidly be produced in
a range from 5%RH to 95%RH by a high performance humidi-
fication system.
Concept of the removable
sensor
The Huminator II is equipped with a reference probe which is
integrated into the measuring chamber but which is nevertheless
easily accessible. It can be exchanged without any problems or
removed for recalibration.
Your advantages:
ü	No need for an additional reference measuring instrument
ü	Only the reference sensor has to be sent in for recalibration.
ü	Downtimes due to the recalibration can be avoided through 	
	 the optional purchase of a second reference sensor.
Easy to use via the touch display
Due to the touch display, the measuring values are comfortable
to control. The clear menu structure enables an intuitive and
simple handling. Help texts are additionally at your disposal.
With the touch display, the Huminator II can be programmed in
a few steps. If required, this process can also be conducted via
the USB interface.
Furthermore, an acoustic signal helps the user to control the
stability and the filling level indicator of the water.
Large measuring chamber
The large and extremely solid measuring chamber provides
enough space for up to five sensors or several data loggers at
the same time. An optimal insulation of the chamber in con-
junction with a special sealing adapter plate ensure the stability
of the measuring values in a wide range of temperature and
humidity.
Menu overview Tabular view Chart Settings
On-site use
The intelligent use of materials enables a total weight of only
19 kg. This makes the Huminator II mobile and flexible to use.
The water can be drained automatically with the help of a
display command. From this it follows, that the Huminator II is
quickly ready for transportation. The optimal protection is given
by an optionally available transport trolley, promising excellent
handling during the on-site use.
Stationary use in the calibration lab
The Huminator II is designed to carry out fast and precise humidity calibrations. In laboratory use, where fast processing times and
continuous operation are of crucial importance, the Huminator is characterized by its outstanding performance and its reliability.
Maintenance & Service
• 	 Besides a power supply, no further external connection is 	
	 required.
•	 Directly accessible help texts are at your disposal on the 	
	 the touch screen. In addition, an electronic instruction 	
	 manual is provided.
•	 The integrated reference enables a fast recalibration. 	
	 Furthermore you benefit from a significant cost reduction 	
	 by saving the external reference.
•	 Due to the service access on the upper side of the housing, 	
	 the drying cartridge can easily be replaced at any time.
•	 You only need distilled water for the Huminators
	 operation, no further operating materials are necessary.
Order information
Huminator II 0519.0900
Accessory Transport trolley
DAkkS-Calibration
2. Reference
0519.0899
On request
0555.6610
Price on request Testo industrial services GmbH
Gewerbestraße 3
79199 Kirchzarten
Germany
www.testotis.com
info@testotis.de
Transport trolley
Flexible, precise, mobile
Technical Data
Specifications
Measuring and
control range
5 to 50 °C 5 to 95 %RH
Stability ± 0.02 °C (at 25 °C;
50 %RH)
± 0,3 %RH (10 to
80 %RH at 10 to 40 °C)
± 0,5 %RH (rem.
measuring range)
Probe accuracy
at 25 °C
± 0.15 °C (0.27 °F)
with PT1000 Class
AA
± (1,0 %RH + 0,007 x
meas. value) for 0 to
90 %RH
Homogeneity ± 0.2°C ± 0,5 %RH
Stabilization time 3 min (from 35 to 80 %RH at 25 °C)
Ambient conditions 20 ± 5 °C
Typical total measuring
uncertainty
of the calibration (k=2)
± 0.2 °C (10 to
85 %RH at 25 °C)
± 0.5 °C (rem.
measuring ran-
ge)	
± 1.5 %RH (10 to
85 %RH at 25 °C)
± 2.0 %RH (rem.
measuring range)
General data
Display Touchscreen
Number of probe slots 5
Interfaces USB, LAN
Power consumption (typical) 30 W to 250 W, max: 500 W
AC input voltage/
-frequency
110 V to 230 V ±10 % 50/60 Hz
Tank volume Tank with a capacity of 200 ml
Water level indicator Completely automatically
with graphic display
Display of measuring data In graphic and tabular form
Control Manually or automatically
programmable
Stabilization signal visually and acoustically
Dimensions (DxWxH) 451 mm x 448 mm x 266 mm
482 mm x 448 mm x 290 mm
(incl. attachments)
Size of the measuring
chamber
Diameter: 160 mm
Depth: 320 mm
Volume of the measuring
chamber
appr. 4.2 liters (inlet: 154 mm,
depth to cooling element:
230 mm)
Weight 19,8 kg
Scope of delivery
Drying cartridge Dry granulates with a change of
color depending on the humidity
content
Operating material Plugs for probes (15 pieces)
Power cord
ISO calibration certificate
Other certifications CE Approval
BGV A3 approved
0980.5194/PC/len/03.2009
448 (depth: 451)
266
Touch-Display Measuring chamber
Ø 160 mm
Dimension drawing
Huminator
precision humidity generator by Testo • Industrial Services
5 - 95 % RH
5 - 50 °C
CHAMBER
Power

More Related Content

PDF
Datasheet Fluke 971. Hubungi PT. Siwali Swantika 021-45850618
PDF
Eta lyra series reflow oven
PDF
Qaw70 b fiche-produit_en
PDF
Hướng dẫn sử dụng máy đo hạt bụi Testo 380
PDF
Mm300 OEM Moisture Transducers
PPT
Humidity (1)
Datasheet Fluke 971. Hubungi PT. Siwali Swantika 021-45850618
Eta lyra series reflow oven
Qaw70 b fiche-produit_en
Hướng dẫn sử dụng máy đo hạt bụi Testo 380
Mm300 OEM Moisture Transducers
Humidity (1)

What's hot (17)

PDF
Esco Medical Mini Miri Humidified Incubator for iIVF applications
PDF
VACUUM STERILIZER
PDF
K Tek Analytics, Mumbai, Balances & Analytical Instruments
PDF
Lead free reflow oven s-1000
PDF
Product E+E
PDF
Industrial drying-oven
PDF
MRU Nova Plus Emissions Analyzer | Portable Flue Gas Analyzer
PDF
Final catalogue equamaster
PDF
Boiler operation technical information
PDF
Sontex Superstatic 440 Static Heat Meter And Cooling Meter - Brochure
PDF
Memograph m rsg 40 endress+hauser datasheet-record, visualize, analyze and co...
PDF
Ellab TrackSense Pro
PDF
Eta draco series reflow oven
PDF
SWG 100 BIO EX | Stationary Biogas Analyzer
PDF
CHAMBER & FURNACE - Environmental Chambers from Tinius Olsen
PDF
Lead free reflow oven s-8800
Esco Medical Mini Miri Humidified Incubator for iIVF applications
VACUUM STERILIZER
K Tek Analytics, Mumbai, Balances & Analytical Instruments
Lead free reflow oven s-1000
Product E+E
Industrial drying-oven
MRU Nova Plus Emissions Analyzer | Portable Flue Gas Analyzer
Final catalogue equamaster
Boiler operation technical information
Sontex Superstatic 440 Static Heat Meter And Cooling Meter - Brochure
Memograph m rsg 40 endress+hauser datasheet-record, visualize, analyze and co...
Ellab TrackSense Pro
Eta draco series reflow oven
SWG 100 BIO EX | Stationary Biogas Analyzer
CHAMBER & FURNACE - Environmental Chambers from Tinius Olsen
Lead free reflow oven s-8800
Ad

Similar to Huminator (20)

PDF
Testo huminator datasheet 2012
PDF
Testo - Huminator
PDF
Hướng dẫn sử dụng Testo 420
PDF
Testo 622 datasheet 2012
PDF
Rotronic HygroGen2 - Data Sheet
PDF
Rotronic Data Sheet HygroGen2-S-XL
PDF
Technical Data Rotronic HygroGen2-S-XL
PDF
W3-031-Water-Vapor-Transmission-rate-Tester
PDF
Testo 623 datasheet 2012
PDF
Hướng dẫn sử dụng máy đo nhiệt độ hồng ngoại Testo 845
PDF
Tea Moisture Meter by ACMAS Technologies Pvt Ltd.
PDF
Testo 175 h1 datasheet
PDF
Rotronic Catalog 2022
PPT
Fluke Corporation: Gas Custody Transfer Calibration
PDF
Water Vapor Transmission Rate Tester
PDF
Testo 610 datasheet 2012
PDF
Hướng dẫn sử dụng máy đo đa năng Testo 435
PDF
Hướng dẫn sử dụng testo 435-3
PDF
Hướng dẫn sử dụng Testo 435-3
PPS
Raj scientific co
Testo huminator datasheet 2012
Testo - Huminator
Hướng dẫn sử dụng Testo 420
Testo 622 datasheet 2012
Rotronic HygroGen2 - Data Sheet
Rotronic Data Sheet HygroGen2-S-XL
Technical Data Rotronic HygroGen2-S-XL
W3-031-Water-Vapor-Transmission-rate-Tester
Testo 623 datasheet 2012
Hướng dẫn sử dụng máy đo nhiệt độ hồng ngoại Testo 845
Tea Moisture Meter by ACMAS Technologies Pvt Ltd.
Testo 175 h1 datasheet
Rotronic Catalog 2022
Fluke Corporation: Gas Custody Transfer Calibration
Water Vapor Transmission Rate Tester
Testo 610 datasheet 2012
Hướng dẫn sử dụng máy đo đa năng Testo 435
Hướng dẫn sử dụng testo 435-3
Hướng dẫn sử dụng Testo 435-3
Raj scientific co
Ad

More from Lothar Zorn (10)

PDF
Testo 400 - O instrumento universal de medição de velocidade do ar e IAQ
PDF
GxP Services for Warehouse Logistics & Transport
PDF
Testo Solar Panel - Practical Guide
PDF
Testo – The Strong Partner for Facility Managers.
PDF
Testo 184 - GxP Dictionary - English
PDF
Testo saveris-restaurant-teaser-brochure-2-br
PDF
Garantia de qualidade dos alimentos e adesão aos regulamentos HACCP em gastro...
PDF
Garantia de qualidade e conformidade nos supermercados
PDF
eBook Totvs - Guia da Prevenção de Perdas em Supermercados
PDF
Catálogo termovisores testo 2017
Testo 400 - O instrumento universal de medição de velocidade do ar e IAQ
GxP Services for Warehouse Logistics & Transport
Testo Solar Panel - Practical Guide
Testo – The Strong Partner for Facility Managers.
Testo 184 - GxP Dictionary - English
Testo saveris-restaurant-teaser-brochure-2-br
Garantia de qualidade dos alimentos e adesão aos regulamentos HACCP em gastro...
Garantia de qualidade e conformidade nos supermercados
eBook Totvs - Guia da Prevenção de Perdas em Supermercados
Catálogo termovisores testo 2017

Recently uploaded (20)

PPTX
33ABJFA6556B1ZP researhchzfrsdfasdfsadzd
PDF
Immigration Law and Communication: Challenges and Solutions {www.kiu.ac.ug)
DOCX
Center Enamel A Strategic Partner for the Modernization of Georgia's Chemical...
PDF
Chapter 2 - AI chatbots and prompt engineering.pdf
PPTX
basic introduction to research chapter 1.pptx
PDF
Robin Fischer: A Visionary Leader Making a Difference in Healthcare, One Day ...
PPT
Retail Management and Retail Markets and Concepts
PDF
Middle East's Most Impactful Business Leaders to Follow in 2025
PDF
income tax laws notes important pakistan
PPTX
operations management : demand supply ch
PPTX
Chapter 2 strategic Presentation (6).pptx
PDF
Kishore Vora - Best CFO in India to watch in 2025.pdf
PPTX
Project Management_ SMART Projects Class.pptx
PDF
Business Communication for MBA Students.
PDF
Highest-Paid CEO in 2025_ You Won’t Believe Who Tops the List.pdf
PPTX
Understanding Procurement Strategies.pptx Your score increases as you pick a ...
PDF
Comments on Clouds that Assimilate Parts I&II.pdf
PPTX
interschool scomp.pptxzdkjhdjvdjvdjdhjhieij
PPTX
BUSINESS CYCLE_INFLATION AND UNEMPLOYMENT.pptx
PDF
533158074-Saudi-Arabia-Companies-List-Contact.pdf
33ABJFA6556B1ZP researhchzfrsdfasdfsadzd
Immigration Law and Communication: Challenges and Solutions {www.kiu.ac.ug)
Center Enamel A Strategic Partner for the Modernization of Georgia's Chemical...
Chapter 2 - AI chatbots and prompt engineering.pdf
basic introduction to research chapter 1.pptx
Robin Fischer: A Visionary Leader Making a Difference in Healthcare, One Day ...
Retail Management and Retail Markets and Concepts
Middle East's Most Impactful Business Leaders to Follow in 2025
income tax laws notes important pakistan
operations management : demand supply ch
Chapter 2 strategic Presentation (6).pptx
Kishore Vora - Best CFO in India to watch in 2025.pdf
Project Management_ SMART Projects Class.pptx
Business Communication for MBA Students.
Highest-Paid CEO in 2025_ You Won’t Believe Who Tops the List.pdf
Understanding Procurement Strategies.pptx Your score increases as you pick a ...
Comments on Clouds that Assimilate Parts I&II.pdf
interschool scomp.pptxzdkjhdjvdjvdjdhjhieij
BUSINESS CYCLE_INFLATION AND UNEMPLOYMENT.pptx
533158074-Saudi-Arabia-Companies-List-Contact.pdf

Huminator

  • 1. Huminator II Precision Humidity Generator Testo Industrial Services – More assurance, better service. www.testotis.com
  • 2. All advantages at a glance Easy operation, fast regulation, good stability and homogeneity ü Fast stabilisation time (e.g. 3 min from 35%RH to 80%RH at 25°C) ü Highest measuring stability due to optimal insulation of the chamber and high-end sealing adapter plate ü Large measuring chamber (Ø 160 mm, depth 320 mm) ü No condensation inside the measuring chamber through a regulation along the dew point ü Guaranteed mobility- the compact size and the minimal weight ensure an extremely flexible use of the Huminator II. ü Wide temperature and humidity range from 5°C to 50°C and from 5%RH to 95%RH ü New touch display enables a fast and intuitive operation ü Graphical and tabular view as well as storage and evaluation of measured values ü Integrated, easily accessible and replaceable reference sensor, that eliminates the need for an external reference system ü Possibility to program measuring points and procedures individually
  • 3. humidity control temperature control measuring chamber reference and control probe (temperature + humidity) peltier element (heat ex- changer) +/-°C +%rH -%rH set points/ actual values touch display (entry of set points, indication of actual values) humidifier drying (e. g. silica gel) Testo 6681 Precise humidity calibrations The Huminator II offers the possibility to perform a rapid and easy humidity calibration of measuring instruments, sensors and data loggers of all manufacturers. The supplied adapter plate enables a calibration of up to five sensors at a time- wi- thout deterioration of the homogeneity. Thus, a high level of efficiency is guaranteed. The timely programming function allows a large degree of auto- mation of calibrations since up to 10 humidity and temperature values can be retrieved automatically one after another. The stabilization time can be selected freely. With the help of a Peltier- element, the integrated temperature regulation generates and stabilizes temperatures in a range from 5°C to 50°C. Relative humidity can rapidly be produced in a range from 5%RH to 95%RH by a high performance humidi- fication system. Concept of the removable sensor The Huminator II is equipped with a reference probe which is integrated into the measuring chamber but which is nevertheless easily accessible. It can be exchanged without any problems or removed for recalibration. Your advantages: ü No need for an additional reference measuring instrument ü Only the reference sensor has to be sent in for recalibration. ü Downtimes due to the recalibration can be avoided through the optional purchase of a second reference sensor.
  • 4. Easy to use via the touch display Due to the touch display, the measuring values are comfortable to control. The clear menu structure enables an intuitive and simple handling. Help texts are additionally at your disposal. With the touch display, the Huminator II can be programmed in a few steps. If required, this process can also be conducted via the USB interface. Furthermore, an acoustic signal helps the user to control the stability and the filling level indicator of the water. Large measuring chamber The large and extremely solid measuring chamber provides enough space for up to five sensors or several data loggers at the same time. An optimal insulation of the chamber in con- junction with a special sealing adapter plate ensure the stability of the measuring values in a wide range of temperature and humidity. Menu overview Tabular view Chart Settings
  • 5. On-site use The intelligent use of materials enables a total weight of only 19 kg. This makes the Huminator II mobile and flexible to use. The water can be drained automatically with the help of a display command. From this it follows, that the Huminator II is quickly ready for transportation. The optimal protection is given by an optionally available transport trolley, promising excellent handling during the on-site use. Stationary use in the calibration lab The Huminator II is designed to carry out fast and precise humidity calibrations. In laboratory use, where fast processing times and continuous operation are of crucial importance, the Huminator is characterized by its outstanding performance and its reliability.
  • 6. Maintenance & Service • Besides a power supply, no further external connection is required. • Directly accessible help texts are at your disposal on the the touch screen. In addition, an electronic instruction manual is provided. • The integrated reference enables a fast recalibration. Furthermore you benefit from a significant cost reduction by saving the external reference. • Due to the service access on the upper side of the housing, the drying cartridge can easily be replaced at any time. • You only need distilled water for the Huminators operation, no further operating materials are necessary. Order information Huminator II 0519.0900 Accessory Transport trolley DAkkS-Calibration 2. Reference 0519.0899 On request 0555.6610 Price on request Testo industrial services GmbH Gewerbestraße 3 79199 Kirchzarten Germany www.testotis.com info@testotis.de Transport trolley
  • 7. Flexible, precise, mobile Technical Data Specifications Measuring and control range 5 to 50 °C 5 to 95 %RH Stability ± 0.02 °C (at 25 °C; 50 %RH) ± 0,3 %RH (10 to 80 %RH at 10 to 40 °C) ± 0,5 %RH (rem. measuring range) Probe accuracy at 25 °C ± 0.15 °C (0.27 °F) with PT1000 Class AA ± (1,0 %RH + 0,007 x meas. value) for 0 to 90 %RH Homogeneity ± 0.2°C ± 0,5 %RH Stabilization time 3 min (from 35 to 80 %RH at 25 °C) Ambient conditions 20 ± 5 °C Typical total measuring uncertainty of the calibration (k=2) ± 0.2 °C (10 to 85 %RH at 25 °C) ± 0.5 °C (rem. measuring ran- ge) ± 1.5 %RH (10 to 85 %RH at 25 °C) ± 2.0 %RH (rem. measuring range) General data Display Touchscreen Number of probe slots 5 Interfaces USB, LAN Power consumption (typical) 30 W to 250 W, max: 500 W AC input voltage/ -frequency 110 V to 230 V ±10 % 50/60 Hz Tank volume Tank with a capacity of 200 ml Water level indicator Completely automatically with graphic display Display of measuring data In graphic and tabular form Control Manually or automatically programmable Stabilization signal visually and acoustically Dimensions (DxWxH) 451 mm x 448 mm x 266 mm 482 mm x 448 mm x 290 mm (incl. attachments) Size of the measuring chamber Diameter: 160 mm Depth: 320 mm Volume of the measuring chamber appr. 4.2 liters (inlet: 154 mm, depth to cooling element: 230 mm) Weight 19,8 kg Scope of delivery Drying cartridge Dry granulates with a change of color depending on the humidity content Operating material Plugs for probes (15 pieces) Power cord ISO calibration certificate Other certifications CE Approval BGV A3 approved
  • 8. 0980.5194/PC/len/03.2009 448 (depth: 451) 266 Touch-Display Measuring chamber Ø 160 mm Dimension drawing Huminator precision humidity generator by Testo • Industrial Services 5 - 95 % RH 5 - 50 °C CHAMBER Power