                        780 pH Meter
                   781 pH/Ion Meter




The measure of all things
Flexible and easy to operate




The 780 pH Meter and the 781 pH/Ion Meter combine the highest Metrohm quality with advanced
design.

pH Meter and Ion Meter
Metrohm's new pH meter generation offers numerous possibilities. In addition to the general func-
tions for measuring pH, potential and temperature, the new pH meters boast features such as the
optimized GLP-compliant electrode test as well as monitoring and service intervals.

With the 781 pH/Ion Meter you can determine ion concentrations at a level of comfort offered only
by Metrohm.




                                                 801 Magnetic Stirrer on the 781 pH/Ion Meter.




                                                         The 804 Ti-Stand with 802 Rod Stirrer
                                                           offers an alternative way of stirring.



                                                                                                    2
Stirrers
    Not only the pH meters are new but also the stirrers have been optimized. They are now directly
    controlled by the pH meter via the MSB interface (MSB = Metrohm Serial Bus). The stirring speed
    is set on the pH Meter. This assures that measurements are always carried out under the same
    conditions.

    You can choose between the 801 Magnetic Stirrer and the 802 Rod Stirrer.



    Electrodes
    Metrohm offers a large range of pH and ion-selective electrodes. Please find an overview of our
    electrode program under www.metrohm.com and additional information on pH measurement
    under www.ph-measurement.com.

    The package of the 780 pH Meter contains the 6.0232.100 Ecotrode pH electrode, that of the
    781 pH/Ion Meter the 6.0258.010 Unitrode pH electrode with integrated Pt 1000 temperature
    sensor.



    Switch on and measure
    Despite the many functions they offer, operation of the new pH meters is easy. After switching on
    the instrument you can immediately measure using the inherent standard parameters. The large
    display accommodates several lines. It provides an excellent overview and facilitates the necessary
    adjustments, which you can then store as your own method under a meaningful name.

    Sample identification can consist of up to 15 ASCII characters. You have
    the option to attach a PC keyboard or – even more comfortable –
    to use a barcode reader for entering sample identifications.




                                                                                       Display of 780 pH Meter
                                                                              with pH value in large characters.
                                                                  Temperature, date and time are also displayed.




3
Practical quality control




Unique: GLP-compliant electrode test
For years Metrohm, as the only manufacturer worldwide, has offered pH meters with GLP-com-
pliant electrode test. With the new pH meters you can carry out a test that is specially adapted
to your electrode type, be it a pH electrode with aqueous, non-aqueous or gel electrolyte. The
electrode test yields specific information such as response time, zero point or slope as well as an
overall statement that informs you about the condition of the membrane and the diaphragm.



pH calibration with automatic buffer recognition
With the 780 pH Meter and the 781 pH/Ion Meter you can perform pH calibrations with up to
9 buffers. Calibrations are made easy by the sophisticated user guidance, automatic buffer recog-
nition and evaluation. You can store the calibration data including curve under the corresponding
electrode identification and view it any time.

                                  Should you wish to use buffers different from those stored in the
                                  instrument, you are free to do so. Just enter the values of your
                                  buffers, either for a given temperature or as a function of tempe-
                                  rature.




                                  Calibration line of a pH electrode.




                                                                                                       4
User identification
    Thanks to the user identification you can always find out, by viewing the report, who performed
    which determination and at what time. The user has also the possibility to confirm the results with
    his signature in the field provided for this purpose on the printout.



    Monitoring intervals
    Forgot validation? Calibration or service interval expired? With the new pH meters these are things
    of the past. Thanks to the integral monitoring functions you are alerted to the corresponding
    quality control tasks in time. The intervals can easily be adjusted to your specific requirements.

    Each time the instrument is switched on it carries out an internal system diagnosis that ensures the
    correct functioning of the pH meter. To complete the documentation you can issue this instrument
    test as a system report.



    Instrument test with 767 Calibrated Reference
    It occasionally happens that the displayed measuring value appears to be untrustworthy. In these
    cases, the reference values supplied by the 767 Calibrated Reference will remove any doubts
    simply and rapidly by letting you gauge the instrument's condition. The Calibrated Reference is
    simply attached in place of the sensor to the instrument to be checked.

    The 767 Calibrated Reference allows to check your instrument within the normal procedure, i.e.
    within established methods. This means that the operational sequences and the methods used
    are tested at the same time.




                                               Checking the pH display of the 781 pH/Ion Meter
                                               with the 767 Calibrated Reference.
5
Two outstanding instruments




                              6
Graphics display grants overview and facilitates operation




    Recall of stored calibration data including calibration curve


    Memory for measured values accommodates up to 100 data sets



    Stirrer control by the pH meter ensures reproducible measuring results




    Inherent quality control tool: pH electrode test for standard electrodes, gel electrodes
    and electrodes for non-aqueous media




    Calibration with automatic buffer recognition, up to 9 calibration buffers




    Measuring ion concentration by means of
    direct measurement, standard additions or
    sample additions. Automation using a 765 or
    776 Dosimat turns calibrations and additions
    into child's play while at the same time
    improving precision.




7
Top-of-the-line ion meter




Easy and comfortable measuring of ion concentrations – a Metrohm exclusive
With the 781 pH/Ion Meter you can determine the content of different ions using ion-selective
electrodes. The determinations are either performed by establishing calibration curves or by carry-
ing out standard or sample additions. Both techniques can be automated with an attached 765 or
776 Dosimat. For the fully automatic standard addition you need only enter the concentration of
your standard and the desired number of additions, the rest is taken care of by the pH/Ion Meter.
Any name can be used for the determined species and the result unit is freely selectable.

Up to 19 standards can be used for calibrations. Evaluation of the calibration curves or of the
additions is carried out automatically by the pH/Ion Meter.

You can obtain the following Metrosensor ion-selective electrodes from us:
• with crystal membrane: F–, Cl–, Pb2+, Cu2+, Ag+, S2–, CN–, I–, Br–, Cd2+, SCN–
• with polymer membrane: Na+, Ca2+, NO3–, K+, BF4–
• with glass membrane: Na+

Application know-how included – in the Internet, under www.metrohm.com, you will find our
Application Notes as well as the list of all our Application Bulletins.



Profitable automation
Whenever larger numbers of samples have to be processed, using a sample changer is advanta-
geous. For the automated measurement of pH values we recommend to combine the 780 pH
Meter with our 824 Easy Sample Changer. If you also wish to determine ion concentrations, for
example the fluoride concentration in mouth rinses, you can use the 781 pH/Ion Meter with our
730 Sample Changer.

Please contact us, we will be pleased to advise you about the optimal adaptation of one of our
sample changer systems for your application.




Determination of the ion concentration with the 781 pH/Ion Meter.
The 765 Dosimat performs the fully automatic standard additions
while the Custom DP40 printer documents the determination.




                                                                                                      8
9
Comparison of two future-proof
instruments




Measuring ranges
      pH

      Potential
      Temperature
              Pt 1000
              NTC
      Concentration


Resolution
      pH
      Potential
      Temperature


Concentration mode
      Automatic concentration calibration with Dosimat
      Automatic standard or sample addition with Dosimat


pH calibration (number of buffers)
Automatic adjustment for the temperature characteristics of the stored buffer solutions
Automatic buffer recognition
Automatic temperature compensation
Automatic self-diagnosis
Automatic GLP-compliant electrode test for different types of pH electrodes
Stability control (drift indicator)
Simultaneous display of pH and temperature
Electrode input (high impendance)
Temperature measuring input for Pt 1000 and NTC
Method memory
Memory for 100 measured values including additional data
GLP-compliant result printout
Automatic monitoring functions (validation, service, calibration, diagnosis)
User identification and field for signature on report
Plot function for pH, mV, °C, concentration versus time (concentration with 781 only)
Connection of printer or PC via RS 232C
MSB connection (Metrohm Serial Bus)
Connection for stirrer control
Connection for PC keyboard and barcode reader
«Remote» sample changer connection
Output lines for limit value check
Dialog guidance in the following languages
Power supply 100...240 V, 50...60 Hz




                                                                                          10
780 pH Meter                 781 pH/Ion Meter




              0...14                          0...14
            (±20.000)                       (±20.000)
            ±2200 mV                        ±2200 mV


      –150.0...+250.0 °C               –150.0...+250.0 °C
         –20.0...+250.0 °C              –20.0...+250.0 °C
                                           10–38...10+38




              0.001                           0.001
              0.1 mV                         0.1 mV
              0.1 °C                          0.1 °C


                                                •
                                                •
                                                •


              1 to 9                          1 to 9
                •                               •
                •                               •
                •                               •
                •                               •
                •                               •
                •                               •
                •                               •
                1                               1
                •                               •
                •                               •
                •                               •
                •                               •
                •                               •
                •                               •
                •                               •
                •                               •
                •                               •
                •                               •
                •                               •
              Option                         Option
              Option                         Option
English, German, French, Spanish English, German, French, Spanish
                •                               •




    11
Ordering information,
options




780 pH Meter
Top-level pH meter with graphics LCD screen for the user dialog in English, German, French or
Spanish as well as for the display of results and calibration curves. pH calibration with up to 9 buf-
fers, automatic buffer recognition, electrode test for different types of pH electrodes. Temperature
measurement with Pt 1000 or NTC. Memories for methods and measured values; automatic moni-
toring functions, plot function for pH, mV, °C versus time.

2.780.0010       pH Meter including 6.0232.100 Ecotrode pH electrode plus stand rod with base
                 and electrode holder as well as line adapter 100...240 V, 50...60 Hz, 12 V DC

781 pH/Ion Meter
Instrument for measuring pH values and determining ion concentrations at the highest level of
comfort; with graphics LCD screen for the user dialog in English, German, French or Spanish as
well as for the display of results and calibration curves. pH calibration with up to 9 buffers, auto-
matic buffer recognition, electrode test for different types of pH electrodes. Concentration mode,
setting up of calibration curves and standard or sample additions automatable with Dosimat.
Temperature measurement with Pt 1000 or NTC. Memories for methods and measured values;
automatic monitoring functions, plot function for pH, mV, °C, concentration versus time.

2.781.0010       pH/Ion Meter including 6.0258.010 Unitrode pH electrode and stand rod with base
                 and electrode holder as well as line adapter 100...240 V, 50...60 Hz, 12 V DC

Options
2.801.0010       801 Magnetic stirrer
2.804.0010       804 Ti Stand
2.802.0040       802 Rod Stirrer
2.765.0010       765 Dosimat with 20 mL Exchange Unit
2.776.0010       776 Dosimat with 20 mL Exchange Unit
6.2148.010       Remote Box for attaching a 25-pin Remote connecting cable and an MSB
                 connecting cable
6.2138.010       Connecting cable 780/781/Remote Box – 765 Dosimat
6.2136.000       Adapter cable for attaching 776 Dosimat to 6.2138.010 cable

2.140.0200       Custom DP40-S4N impact printer
6.2134.110       Connecting cable 780/781 – Custom printer

6.1110.100       Pt 1000 temperature sensor with plug-in head G
6.2104.140       Cable for 6.1110.100, length 1 m, with two 2 mm plugs

6.2307.100       Buffer solution pH = 4, ready-to-use, 500 mL
6.2307.110       Buffer solution pH = 7, ready-to-use, 500 mL
6.2307.120       Buffer solution pH = 9, ready-to-use, 500 mL
                                                                                                         Ecknauer+Schoch ASW.e.09.02




I o n     a n a l y s i s
Metrohm Ltd.
CH-9101 Herisau/Switzerland
Phone +41 71 353 85 85
Fax +41 71 353 89 01
www.metrohm.com
info@metrohm.com

More Related Content

PDF
Testo 521 datasheet 2012
DOCX
Xitij-LABTRONICS CATALOG
PDF
Photon-Instruments-Company-Profile
PDF
Combination of pH and ORP electrode
PPTX
Testing and Troubleshooting 4-20 mA Control Loops Presented by Fluke and Tra...
PDF
Thermometers calibration
PPTX
Automating Temperature Sensor Calibration
PPTX
How to Calibrate an IR Thermometer Webinar Presented by Fluke Calibration
Testo 521 datasheet 2012
Xitij-LABTRONICS CATALOG
Photon-Instruments-Company-Profile
Combination of pH and ORP electrode
Testing and Troubleshooting 4-20 mA Control Loops Presented by Fluke and Tra...
Thermometers calibration
Automating Temperature Sensor Calibration
How to Calibrate an IR Thermometer Webinar Presented by Fluke Calibration

What's hot (17)

PDF
Sodium Analyzer for Industrial Applications
PDF
K Tek Analytics, Mumbai, Balances & Analytical Instruments
PPTX
How to Use a Portable Bath to Improve Calibration of Sanitary RTD's and Trans...
PDF
Tester and rapid kit for analysis catalog
PDF
Shah Electronics & Electricals, Mumbai, Industrial Thermocouples & RTD's
PPTX
Oxygen analyser
PDF
PPTX
Alpha Technics
PDF
Atac brochure-cloud point analyser
DOCX
Gas analyzers
PDF
Testo Measurement Solutions for Pharma Industry Applications
PDF
In Situ Infrared Gas Analyzer
PPTX
CO/CO2 level indicator Seminar
PPTX
An introduction to temperature control
PDF
IRJET - Control System for Aquarium Maintenance
PDF
Onset HOBO Datenlogger Produktkatalog 2020
PDF
General catalog of hnl
Sodium Analyzer for Industrial Applications
K Tek Analytics, Mumbai, Balances & Analytical Instruments
How to Use a Portable Bath to Improve Calibration of Sanitary RTD's and Trans...
Tester and rapid kit for analysis catalog
Shah Electronics & Electricals, Mumbai, Industrial Thermocouples & RTD's
Oxygen analyser
Alpha Technics
Atac brochure-cloud point analyser
Gas analyzers
Testo Measurement Solutions for Pharma Industry Applications
In Situ Infrared Gas Analyzer
CO/CO2 level indicator Seminar
An introduction to temperature control
IRJET - Control System for Aquarium Maintenance
Onset HOBO Datenlogger Produktkatalog 2020
General catalog of hnl
Ad

Similar to Ion Meter from Metrohm (20)

PPTX
PH Meter (1).pptx PH Meter (1).pptx PH Meter (1).pptx
PDF
pH meter.pdf
PDF
Eutech Ph 510
PDF
Lutron PH-207 PH-mV-TEMP. Meter
PPT
pH and pH meter
PPTX
18 pH Meter.pptx
PDF
PDF
888 Titrando for Titration Applications from Metrohm
PPT
pH measurement.ppt sums university of iran
PPTX
ph-meter and its type and calibration uses
PPTX
pH Analzyer
PPTX
P h metry
PPTX
ph meter by amit rulhania
PDF
222 Chapter pH meter detail and calibration details 5-1.pdf
PDF
pH Measurement Principles and Best Measurement Practices | Webinar
PDF
Introduction to-ph
PPTX
Ph and ph meter and application in foods
PPTX
JAndrew/PH meter.pptx
PPTX
Measurement of p h
PPT
P h and ph meter
PH Meter (1).pptx PH Meter (1).pptx PH Meter (1).pptx
pH meter.pdf
Eutech Ph 510
Lutron PH-207 PH-mV-TEMP. Meter
pH and pH meter
18 pH Meter.pptx
888 Titrando for Titration Applications from Metrohm
pH measurement.ppt sums university of iran
ph-meter and its type and calibration uses
pH Analzyer
P h metry
ph meter by amit rulhania
222 Chapter pH meter detail and calibration details 5-1.pdf
pH Measurement Principles and Best Measurement Practices | Webinar
Introduction to-ph
Ph and ph meter and application in foods
JAndrew/PH meter.pptx
Measurement of p h
P h and ph meter
Ad

More from Metrohm India Limited (20)

PDF
Manual titration can be automated with ECO TITRATOR - save time and increase ...
PDF
Global webinar on Advanced solutions for battery material characterization
PDF
IIT Bombay Metrohm Young Chemist Award 2019
PDF
Application note on purified water for mammalian and bacterial cell culture
PDF
Brochure power plantanalysis
PDF
875 kf gas analyzer
PDF
Petrochemical Analysis
PDF
Environmental analysis
PDF
Ti touch brochure
PDF
Coulometer for low level water determination in sample matrix
PDF
Metrohm – customized analysis for surface finishing, Process control in elect...
PDF
Surface finishing
PDF
pH / Ion meter from Metrohm
PDF
Ion Chromatography in determining mineral acids in Etching baths
PDF
Battery research
PDF
Biofuels analysis from Metrohm
PDF
Accessories by Metrohm India
PDF
Tiamo software from Metrohm
PDF
797 VA For Trace analysis
PDF
850 intelligent-ion-chromatography by Metrohm
Manual titration can be automated with ECO TITRATOR - save time and increase ...
Global webinar on Advanced solutions for battery material characterization
IIT Bombay Metrohm Young Chemist Award 2019
Application note on purified water for mammalian and bacterial cell culture
Brochure power plantanalysis
875 kf gas analyzer
Petrochemical Analysis
Environmental analysis
Ti touch brochure
Coulometer for low level water determination in sample matrix
Metrohm – customized analysis for surface finishing, Process control in elect...
Surface finishing
pH / Ion meter from Metrohm
Ion Chromatography in determining mineral acids in Etching baths
Battery research
Biofuels analysis from Metrohm
Accessories by Metrohm India
Tiamo software from Metrohm
797 VA For Trace analysis
850 intelligent-ion-chromatography by Metrohm

Recently uploaded (20)

PDF
1911 Gold Corporate Presentation Aug 2025.pdf
PDF
ANALYZING THE OPPORTUNITIES OF DIGITAL MARKETING IN BANGLADESH TO PROVIDE AN ...
PPT
Lecture 3344;;,,(,(((((((((((((((((((((((
PPTX
BUSINESS CYCLE_INFLATION AND UNEMPLOYMENT.pptx
PPTX
IITM - FINAL Option - 01 - 12.08.25.pptx
PDF
Robin Fischer: A Visionary Leader Making a Difference in Healthcare, One Day ...
PDF
Introduction to Generative Engine Optimization (GEO)
PPTX
CTG - Business Update 2Q2025 & 6M2025.pptx
DOCX
FINALS-BSHhchcuvivicucucucucM-Centro.docx
DOCX
Center Enamel A Strategic Partner for the Modernization of Georgia's Chemical...
PDF
533158074-Saudi-Arabia-Companies-List-Contact.pdf
PDF
NEW - FEES STRUCTURES (01-july-2024).pdf
PDF
Environmental Law Communication: Strategies for Advocacy (www.kiu.ac.ug)
DOCX
Handbook of Entrepreneurship- Chapter 5: Identifying business opportunity.docx
DOCX
80 DE ÔN VÀO 10 NĂM 2023vhkkkjjhhhhjjjj
PPTX
Slide gioi thieu VietinBank Quy 2 - 2025
PDF
Satish NS: Fostering Innovation and Sustainability: Haier India’s Customer-Ce...
PPTX
Project Management_ SMART Projects Class.pptx
DOCX
Hand book of Entrepreneurship 4 Chapters.docx
PDF
PMB 401-Identification-of-Potential-Biotechnological-Products.pdf
1911 Gold Corporate Presentation Aug 2025.pdf
ANALYZING THE OPPORTUNITIES OF DIGITAL MARKETING IN BANGLADESH TO PROVIDE AN ...
Lecture 3344;;,,(,(((((((((((((((((((((((
BUSINESS CYCLE_INFLATION AND UNEMPLOYMENT.pptx
IITM - FINAL Option - 01 - 12.08.25.pptx
Robin Fischer: A Visionary Leader Making a Difference in Healthcare, One Day ...
Introduction to Generative Engine Optimization (GEO)
CTG - Business Update 2Q2025 & 6M2025.pptx
FINALS-BSHhchcuvivicucucucucM-Centro.docx
Center Enamel A Strategic Partner for the Modernization of Georgia's Chemical...
533158074-Saudi-Arabia-Companies-List-Contact.pdf
NEW - FEES STRUCTURES (01-july-2024).pdf
Environmental Law Communication: Strategies for Advocacy (www.kiu.ac.ug)
Handbook of Entrepreneurship- Chapter 5: Identifying business opportunity.docx
80 DE ÔN VÀO 10 NĂM 2023vhkkkjjhhhhjjjj
Slide gioi thieu VietinBank Quy 2 - 2025
Satish NS: Fostering Innovation and Sustainability: Haier India’s Customer-Ce...
Project Management_ SMART Projects Class.pptx
Hand book of Entrepreneurship 4 Chapters.docx
PMB 401-Identification-of-Potential-Biotechnological-Products.pdf

Ion Meter from Metrohm

  • 1. I o n Metrohm a n a l y s i s 780 pH Meter 781 pH/Ion Meter The measure of all things
  • 2. Flexible and easy to operate The 780 pH Meter and the 781 pH/Ion Meter combine the highest Metrohm quality with advanced design. pH Meter and Ion Meter Metrohm's new pH meter generation offers numerous possibilities. In addition to the general func- tions for measuring pH, potential and temperature, the new pH meters boast features such as the optimized GLP-compliant electrode test as well as monitoring and service intervals. With the 781 pH/Ion Meter you can determine ion concentrations at a level of comfort offered only by Metrohm. 801 Magnetic Stirrer on the 781 pH/Ion Meter. The 804 Ti-Stand with 802 Rod Stirrer offers an alternative way of stirring. 2
  • 3. Stirrers Not only the pH meters are new but also the stirrers have been optimized. They are now directly controlled by the pH meter via the MSB interface (MSB = Metrohm Serial Bus). The stirring speed is set on the pH Meter. This assures that measurements are always carried out under the same conditions. You can choose between the 801 Magnetic Stirrer and the 802 Rod Stirrer. Electrodes Metrohm offers a large range of pH and ion-selective electrodes. Please find an overview of our electrode program under www.metrohm.com and additional information on pH measurement under www.ph-measurement.com. The package of the 780 pH Meter contains the 6.0232.100 Ecotrode pH electrode, that of the 781 pH/Ion Meter the 6.0258.010 Unitrode pH electrode with integrated Pt 1000 temperature sensor. Switch on and measure Despite the many functions they offer, operation of the new pH meters is easy. After switching on the instrument you can immediately measure using the inherent standard parameters. The large display accommodates several lines. It provides an excellent overview and facilitates the necessary adjustments, which you can then store as your own method under a meaningful name. Sample identification can consist of up to 15 ASCII characters. You have the option to attach a PC keyboard or – even more comfortable – to use a barcode reader for entering sample identifications. Display of 780 pH Meter with pH value in large characters. Temperature, date and time are also displayed. 3
  • 4. Practical quality control Unique: GLP-compliant electrode test For years Metrohm, as the only manufacturer worldwide, has offered pH meters with GLP-com- pliant electrode test. With the new pH meters you can carry out a test that is specially adapted to your electrode type, be it a pH electrode with aqueous, non-aqueous or gel electrolyte. The electrode test yields specific information such as response time, zero point or slope as well as an overall statement that informs you about the condition of the membrane and the diaphragm. pH calibration with automatic buffer recognition With the 780 pH Meter and the 781 pH/Ion Meter you can perform pH calibrations with up to 9 buffers. Calibrations are made easy by the sophisticated user guidance, automatic buffer recog- nition and evaluation. You can store the calibration data including curve under the corresponding electrode identification and view it any time. Should you wish to use buffers different from those stored in the instrument, you are free to do so. Just enter the values of your buffers, either for a given temperature or as a function of tempe- rature. Calibration line of a pH electrode. 4
  • 5. User identification Thanks to the user identification you can always find out, by viewing the report, who performed which determination and at what time. The user has also the possibility to confirm the results with his signature in the field provided for this purpose on the printout. Monitoring intervals Forgot validation? Calibration or service interval expired? With the new pH meters these are things of the past. Thanks to the integral monitoring functions you are alerted to the corresponding quality control tasks in time. The intervals can easily be adjusted to your specific requirements. Each time the instrument is switched on it carries out an internal system diagnosis that ensures the correct functioning of the pH meter. To complete the documentation you can issue this instrument test as a system report. Instrument test with 767 Calibrated Reference It occasionally happens that the displayed measuring value appears to be untrustworthy. In these cases, the reference values supplied by the 767 Calibrated Reference will remove any doubts simply and rapidly by letting you gauge the instrument's condition. The Calibrated Reference is simply attached in place of the sensor to the instrument to be checked. The 767 Calibrated Reference allows to check your instrument within the normal procedure, i.e. within established methods. This means that the operational sequences and the methods used are tested at the same time. Checking the pH display of the 781 pH/Ion Meter with the 767 Calibrated Reference. 5
  • 7. Graphics display grants overview and facilitates operation Recall of stored calibration data including calibration curve Memory for measured values accommodates up to 100 data sets Stirrer control by the pH meter ensures reproducible measuring results Inherent quality control tool: pH electrode test for standard electrodes, gel electrodes and electrodes for non-aqueous media Calibration with automatic buffer recognition, up to 9 calibration buffers Measuring ion concentration by means of direct measurement, standard additions or sample additions. Automation using a 765 or 776 Dosimat turns calibrations and additions into child's play while at the same time improving precision. 7
  • 8. Top-of-the-line ion meter Easy and comfortable measuring of ion concentrations – a Metrohm exclusive With the 781 pH/Ion Meter you can determine the content of different ions using ion-selective electrodes. The determinations are either performed by establishing calibration curves or by carry- ing out standard or sample additions. Both techniques can be automated with an attached 765 or 776 Dosimat. For the fully automatic standard addition you need only enter the concentration of your standard and the desired number of additions, the rest is taken care of by the pH/Ion Meter. Any name can be used for the determined species and the result unit is freely selectable. Up to 19 standards can be used for calibrations. Evaluation of the calibration curves or of the additions is carried out automatically by the pH/Ion Meter. You can obtain the following Metrosensor ion-selective electrodes from us: • with crystal membrane: F–, Cl–, Pb2+, Cu2+, Ag+, S2–, CN–, I–, Br–, Cd2+, SCN– • with polymer membrane: Na+, Ca2+, NO3–, K+, BF4– • with glass membrane: Na+ Application know-how included – in the Internet, under www.metrohm.com, you will find our Application Notes as well as the list of all our Application Bulletins. Profitable automation Whenever larger numbers of samples have to be processed, using a sample changer is advanta- geous. For the automated measurement of pH values we recommend to combine the 780 pH Meter with our 824 Easy Sample Changer. If you also wish to determine ion concentrations, for example the fluoride concentration in mouth rinses, you can use the 781 pH/Ion Meter with our 730 Sample Changer. Please contact us, we will be pleased to advise you about the optimal adaptation of one of our sample changer systems for your application. Determination of the ion concentration with the 781 pH/Ion Meter. The 765 Dosimat performs the fully automatic standard additions while the Custom DP40 printer documents the determination. 8
  • 9. 9
  • 10. Comparison of two future-proof instruments Measuring ranges pH Potential Temperature Pt 1000 NTC Concentration Resolution pH Potential Temperature Concentration mode Automatic concentration calibration with Dosimat Automatic standard or sample addition with Dosimat pH calibration (number of buffers) Automatic adjustment for the temperature characteristics of the stored buffer solutions Automatic buffer recognition Automatic temperature compensation Automatic self-diagnosis Automatic GLP-compliant electrode test for different types of pH electrodes Stability control (drift indicator) Simultaneous display of pH and temperature Electrode input (high impendance) Temperature measuring input for Pt 1000 and NTC Method memory Memory for 100 measured values including additional data GLP-compliant result printout Automatic monitoring functions (validation, service, calibration, diagnosis) User identification and field for signature on report Plot function for pH, mV, °C, concentration versus time (concentration with 781 only) Connection of printer or PC via RS 232C MSB connection (Metrohm Serial Bus) Connection for stirrer control Connection for PC keyboard and barcode reader «Remote» sample changer connection Output lines for limit value check Dialog guidance in the following languages Power supply 100...240 V, 50...60 Hz 10
  • 11. 780 pH Meter 781 pH/Ion Meter 0...14 0...14 (±20.000) (±20.000) ±2200 mV ±2200 mV –150.0...+250.0 °C –150.0...+250.0 °C –20.0...+250.0 °C –20.0...+250.0 °C 10–38...10+38 0.001 0.001 0.1 mV 0.1 mV 0.1 °C 0.1 °C • • • 1 to 9 1 to 9 • • • • • • • • • • • • • • 1 1 • • • • • • • • • • • • • • • • • • • • • • Option Option Option Option English, German, French, Spanish English, German, French, Spanish • • 11
  • 12. Ordering information, options 780 pH Meter Top-level pH meter with graphics LCD screen for the user dialog in English, German, French or Spanish as well as for the display of results and calibration curves. pH calibration with up to 9 buf- fers, automatic buffer recognition, electrode test for different types of pH electrodes. Temperature measurement with Pt 1000 or NTC. Memories for methods and measured values; automatic moni- toring functions, plot function for pH, mV, °C versus time. 2.780.0010 pH Meter including 6.0232.100 Ecotrode pH electrode plus stand rod with base and electrode holder as well as line adapter 100...240 V, 50...60 Hz, 12 V DC 781 pH/Ion Meter Instrument for measuring pH values and determining ion concentrations at the highest level of comfort; with graphics LCD screen for the user dialog in English, German, French or Spanish as well as for the display of results and calibration curves. pH calibration with up to 9 buffers, auto- matic buffer recognition, electrode test for different types of pH electrodes. Concentration mode, setting up of calibration curves and standard or sample additions automatable with Dosimat. Temperature measurement with Pt 1000 or NTC. Memories for methods and measured values; automatic monitoring functions, plot function for pH, mV, °C, concentration versus time. 2.781.0010 pH/Ion Meter including 6.0258.010 Unitrode pH electrode and stand rod with base and electrode holder as well as line adapter 100...240 V, 50...60 Hz, 12 V DC Options 2.801.0010 801 Magnetic stirrer 2.804.0010 804 Ti Stand 2.802.0040 802 Rod Stirrer 2.765.0010 765 Dosimat with 20 mL Exchange Unit 2.776.0010 776 Dosimat with 20 mL Exchange Unit 6.2148.010 Remote Box for attaching a 25-pin Remote connecting cable and an MSB connecting cable 6.2138.010 Connecting cable 780/781/Remote Box – 765 Dosimat 6.2136.000 Adapter cable for attaching 776 Dosimat to 6.2138.010 cable 2.140.0200 Custom DP40-S4N impact printer 6.2134.110 Connecting cable 780/781 – Custom printer 6.1110.100 Pt 1000 temperature sensor with plug-in head G 6.2104.140 Cable for 6.1110.100, length 1 m, with two 2 mm plugs 6.2307.100 Buffer solution pH = 4, ready-to-use, 500 mL 6.2307.110 Buffer solution pH = 7, ready-to-use, 500 mL 6.2307.120 Buffer solution pH = 9, ready-to-use, 500 mL Ecknauer+Schoch ASW.e.09.02 I o n a n a l y s i s Metrohm Ltd. CH-9101 Herisau/Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 www.metrohm.com info@metrohm.com