SlideShare a Scribd company logo
The right choice
for your application.
Level sensors
from ifm.
www.ifm.com
Levelsensors
years
W
ARRANTY
on ifm produ
cts
2
Systems for level monitoring.
The optimum solution for every requirement.
Impedance
spectroscopy
Point level
Continuous
level measurement
Capacitive
in contact with
the medium
Capacitive
without contact
Capacitive
continuous
Guided
wave radar
Hydrostatic
Photoelectric
Accessories
Alternative to
vibrating forks
Suppression of
residues and foam
For contact with
the medium
Overflow protection
Leakage monitoring
For the detection
through non-metallic
tanks
For applications
on hydraulic and
coolant tanks
For industrial and
hygienic applications
For industrial and
hygienic applications
On tanks and
in free-flowing
waterways
For long distances
without contact
to the medium
Adapters for
level sensors in
industrial and
hygienic applications
3
Impedance
spectroscopy
Sensortype
M
ax.m
easuring
range
[cm
]
A
nalogue
output
4 - 5LMT –
EHEDG
3A
FDA
EC1935
WHG
ATEX
Capacitivein
contactwith
themedium
6 - 7LI – WHG
Capacitive
without
contact
8 - 9KG, KI, KQ –
–
–
–
Capacitive
continuous
10-11LK, LT 73 WHG
Guided
waveradar
12-15LR 200
EHEDG
3A
FDA
EC1935
WHG
Hydrostatic
16-19
PG, PI,
PA, PS, PN
–
EHEDG
3A
FDA
EC1935
ATEX
Photoelectric
20-21O1D 980
Accessories
22-23
Sw
itching
output
A
pprovals
G 1/2 11 LMT100 LMT191 –
Reliable detection:
Suppression of residues,
splashing water or foam.
Better than a tuning fork:
No mechanical components, fully
compatible regarding installation
and function.
Immediately ready for use:
Factory settings for the
most common media.
Adaptable using IO-Link:
Adaptation to and differentiation
of media configurable.
More transparency:
Read process values to optimise
the application.
Hygienic design:
High-grade stainless steel
housing with PEEK sensor tip
and maintenance-free sealing
concept.
4
For hygienic areas
and viscous media
Type LMT
level sensor
Flexible mounting
thanks to orienta-
tion-independent
installation.
Shock and vibra-
tion resistant in a
robust stainless
steel housing.
Hygienic approvals
EHEDG, 3A and
FDA.
Versions available
as overflow
protection.
Complementary
switching outputs.
Process
connection
Installation
length
[mm]
Order no. Order no. Order no.
Approvals
Preset to aqueous media
Hygienic WHG* ATEX
G 1/2 38 LMT102 LMT192 –
G 1/2 153 LMT104 LMT194 –
G 1/2 253 LMT105 LMT195 –
G 3/4 28 LMT202 LMT292 –
G 1 38 LMT302 LMT392 –
G 1/2 11 LMT110 – –
Preset to oils, fats, powder
G 1/2 11 LMT121 – –
Preset to sugary media
G 1/2 11 – – LMT01A
G 1/2 153 – – LMT03A
G 1/2 253 – – LMT04A
* German Federal Water Act
Manhole
monitoring
Full
monitoring
Empty
monitoring
Run-dry
protection
Point level detection with impedance spectroscopy.
The reliable and fast alternative to tuning forks.
5
Impedance
spectroscopy
Capacitivein
contactwith
themedium
Capacitive
without
contact
Capacitive
continuous
Guided
waveradar
HydrostaticPhotoelectricAccessories
For adapters
see pages
22 - 23
Ready in no time:
Easy mounting adjustment.
Flexible:
Normally closed / normally open
programmable.
Clear:
Clearly visible indication of
the switch points.
Variable use:
Installation depths of
132 to 737 mm.
Certified:
Approval as overflow protection
or leakage sensor to the
German Federal Water Act.
For industrial
applications
Type LI
point level sensor
Optimised for use
in hydraulic oils
and coolants.
Modular mount-
ing concept for
flexible use.
It only takes one
push of a button
to adjust and
set the output
function.
6
132 0...35 (0...65)1) 0...65 LI5141
Rod length
[mm]
Water
temperature
[°C]
Oil
temperature
[°C]
Order no.
1 switching output, normally closed / normally open programmable
1 switching output, normally closed
Overflow protection to the WHG*
273 0...35 (0...65)1) 0...65 LI5142
481 0...35 (0...65)1) 0...65 LI5143
737 0...35 (0...65)1) 0...65 LI5144
132 0...35 0...65 LI2141
273 0...35 0...65 LI2142
481 0...35 0...65 LI2143
Leakage sensor to the WHG*
132 0...35 0...65 LI2241
273 0...35 0...65 LI2242
481 0...35 0...65 LI2243
* German Federal Water Act
1) in connection with climatic tube, see accessories page 23
Capacitive point level.
In contact with the medium –
protection against overflow and leakage.
7
Order now.
0800 16 16 16 4 or
in the e-shop at
www.ifm.com
Impedance
spectroscopy
Capacitivein
contactwith
themedium
Capacitive
without
contact
Capacitive
continuous
Guided
waveradar
HydrostaticPhotoelectricAccessories
For adapters
see pages
22 - 23
Convenient:
Many functions such as binary
switching output, timer functions
as output, damping function as
well as NC / NO function.
Communicative:
Process values, parameter setting
data and diagnostic information
can be transmitted via IO-Link.
Easy:
Parameter setting via IO-Link
before installation, as an alter-
native also via pushbuttons on
the sensor.
Repeatable:
Simple parameter setting of
many sensors via “copy & paste”
in the LINERRECORDER SENSOR
software or via a memory plug.
Clear:
Clearly visible LEDs indicate the
switching status.
Type KG / KI
point level sensors
Capacitive sensors
in cylindrical M18
or M30 housing.
8
For industrial
applications
8 nf Cable • KG50691)
Sensing
range
[mm]
Connection Teach
function
Order no.
DC PNP
M18 housing, plastic
15 nf
M12
connector
– KI5052
M30 housing, plastic
20 nf
M12
connector
• KI5083
8 f
M12
connector
• KI5085
M30 housing, metal
15 nf
M12
connector
• KI5087
8 nf
M12
connector
– KG5057
• KG5071
12 nf
M12
connector
• KG5066
1) Housing, white PP
f: flush installation nf: non-flush installation
9
Capacitive point level.
Detection through non-metallic tank walls.
Impedance
spectroscopy
Capacitivein
contactwith
themedium
Capacitive
without
contact
Capacitive
continuous
Guided
waveradar
HydrostaticPhotoelectricAccessories
Sensing
range
[mm]
Connection Order no.
DC PNP
12 nf
Cable 2 m KQ6002
Cable 10 m KQ6007
12 nf
Cable plug
M8
KQ6004
12 nf
Cable plug
M12
KQ6005
Type KQ
point level sensor
Capacitive sensors
in small plastic
rectangular
housing.
Easy installation
with mounting
adapters and
fixing straps.
DC NPN
12 nf
12 nf
Cable 2 m KQ6006
Cable plug
M12
KQ6016
DC PNP
12 nf
12 nf
Cable 2 m KQ5100
Cable plug
M12
KQ5101
12 nf
Cable plug
M8
KQ5102
f: flush installation nf: non-flush installation
Professional:
For industrial applications.
Manifold:
Versions with 2 or 4 switching
outputs or analogue output
4...20 mA / 0...10 V.
Safe:
Type LK12 with approval as
overflow protection.
Combined:
Type LT for level and temperature
monitoring.
Type LK
level sensor
Display and hand-
ling directly on
the unit.
As an option with
analogue output
or up to four
switching outputs.
Suitable for oil
temperatures up
to 70 °C.
Versions to the
German Federal
Water Act
available.
For industrial
applications
264 LK1022
Rod length
[mm]
Version Order no.
2 switching outputs
1 switching output, 1 analogue output 4...20 mA, 0...10 V
472 LK1023
728 LK1024
264 WHG* LK1222
472 WHG* LK1223
728 WHG* LK1224
10
264 LK3122
472 LK3123
728 LK3124
2 switching outputs
264
Automatic
medium detection
LK7022
472 LK7023
728 LK7024
4 switching outputs
264 LK8122
472 LK8123
728 LK8124
* German Federal Water Act
Continuous capacitive level measurement.
For applications on hydraulic and coolant tanks.
Impedance
spectroscopy
Capacitivein
contactwith
themedium
Capacitive
without
contact
Capacitive
continuous
Guided
waveradar
HydrostaticPhotoelectricAccessories
Type LT
level sensor
For level and
temperature.
Suitable for oils up
to 70 °C.
11
264 For level and temperature LT8022
Rod length
[mm]
Version Order no.
2 x 2 switching outputs level / temperature
472 For level and temperature LT8023
728 For level and temperature LT8024
For adapters
see pages
22 - 23
Versatile:
Modular sensor concept, flexible
in use.
Variable:
Rods can be cut to size as
required.
Reliable:
Measuring principle independent
of temperature influences.
Optional outputs:
Versions with two or four
switching outputs or analogue
output 4...20 mA / 0...10 V.
Selectable:
Designs with and without
display.
Type LR
level sensor
Display and hand-
ling on the unit or
via IO-Link.
As an option with
analogue output
or up to four
switching outputs.
Rod lengths
freely selectable
between
10...200 cm.
Versions to the
German Federal
Water Act
available.
G 3/4 male LR2050
Process
connection
Order no.
2 switching outputs or 1 switching output and
1 analogue output 4...20 mA
G 3/4 male LR7000
3/4" NPT LR7300
Process
connection
Order no.
2 switching outputs
G 3/4 male LR9020
Process
connection
Order no.
1 analogue output 4...20 mA or 0...10 V
G 3/4 male LR3000
3/4" NPT LR3300
1 switching output and
1 analogue output 4...20 mA or 0...10 V
For industrial
applications
For hygienic areas
and viscous media
12
Type LR
level transmitter
For industrial
applications.
Analogue output
scalable
4...20 mA / 0...10 V.
Protection rating
IP 69K.
Easily adjustable
via IO-Link.
G 3/4 male LR8000
3/4" NPT LR8300
4 switching outputs
G 3/4 male LR80101)
4 switching outputs / WHG*
* German Federal Water Act
1) Only in connection with rod and coaxial pipe,
see page 14
Continuous level measurement
with guided microwave.
For industrial and hygienic applications.
Impedance
spectroscopy
Capacitivein
contactwith
themedium
Capacitive
without
contact
Capacitive
continuous
Guided
waveradar
HydrostaticPhotoelectricAccessories
Aseptoflex Vario G1 LR2750
Process
connection
Order no.
2 switching outputs or 1 switching output and
1 analogue output 4...20 mA
Type LR27
hygienic level
sensor
Display and hand-
ling on the unit or
via IO-Link.
Medium tempera-
ture -guatda.com/cmx.p40...150 °C.
Pressure-resistant
up to 40 bar.
Rod lengths
of 15...200 cm
selectable.
13
For rods and
coaxial pipes
see pages
14 - 15
For adapters
see pages
22 - 23
G 3/4
G 3/4
14
For industrial
applications
For hygienic areas
and viscous media
700 E43205
Length
[mm]
Order no.
Level sensor
3/4" NPT
Type LR3300
Type LR7300
Type LR8300
800 E43337
1000 E43207
1200 E43208
1400 E43209
1600 E43210
2000 E433532)
2) Only for type LR2050 sensor
150 E43225
Length
[mm]
Order no.
210 E43351
240 E43203
265 E43352
300 E43226
450 E43204
500 E43227
Rods for LR level
sensors with 3/4"
NPT oder G 3/4
male, industrial
applications
Material:
high-grade
stainless steel
(1.4404 / 316L)
1) Only in connection
with rod and
coaxial pipe
Level sensor
G 3/4 male
Type LR2050
Type LR3000
Type LR7000
Type LR8000
Type LR80101)
Type LR9020
150 E43230
Process
connection
Length
[mm]
Order no.
210 E43354
240 E43211
265 E43355
300 E43228
450 E43212
500 E43229
700 E43213
800 E43336
1000 E43214
1200 E43215
1400 E43216
1600 E43217
2000 E433562)
700, slotted E43333
1200, slotted E43334
2) Only for type LR2050 sensor
Coaxial pipes for
LR level sensors
with G 3/4 male,
industrial
applications
Material:
high-grade
stainless steel
(1.4301 / 304)
15
Continuous level measurement
with guided microwave.
Rods and coaxial pipes.
Impedance
spectroscopy
Capacitivein
contactwith
themedium
Capacitive
without
contact
Capacitive
continuous
Guided
waveradar
HydrostaticPhotoelectricAccessories
3/4" NPT
450 E43218
Process
connection
Length
[mm]
Order no.
700 E43219
1000 E43220
1200 E43223
1400 E43224
1600 E43221
150 E43345
Length
[mm]
Order no.
300 E43346
500 E43340
700 E43347
1000 E43341
1500 E43348
2000 E43342
Type LR2750
hygienic level
sensor
Rods for level
sensor type
LR2750, hygienic
applications
Material:
high-grade
stainless steel
(1.4404 / 316L)
For a wide
selection of other
accessories visit
www.ifm.com
For adapters
see pages
22 - 23
16
Robust:
Overload-protected measuring
principles with a good long-term
stability.
Versatile:
Compact sensors with and
without display.
Precise:
Ceramic-capacitive and
piezoresistive measuring cells.
For industrial
applications
Type PA
pressure sensor
2-wire pressure
transmitter.
Ceramic-capacitive
measuring cell.
G 1/4 female 0...1000 0...1000 PA9027
Process
connection
Relative pressure
measuring range
[mbar]
Relative pressure
measuring range
[mbar]
Order no.
Analogue output 4...20 mA Analogue output 0...10 V
Type PS
submersible
pressure
transmitter
PUR or FEP cable
for high resistance
to media.
Version with ATEX
approval for
group I cat. M1
and group II
cat. 1G and 1D.
Pressure compen-
sation via inter-
nally vented cable.
Order no.
PA3027
G 1/4 female 0...250 0...250 PA9028PA3028
G 1/4 male 0...250 PA3528
G 1/4 male 0...100 PA3589
0.25 FEP, 5 PS4208
Relative pressure
measuring range
[mbar]
Cable
[m]
Order no.
For high resistance to media, CE approval
0.6 FEP, 10 PS4407
1 FEP, 15 PS4417
0.25 FEP, 5 PS308A
For hazardous areas, CE, Ex, GL approvals
0.6 FEP, 10 PS307A
1 FEP, 15 PS317A
0.25 PUR, 5 PS3208
Relative pressure
measuring range
[mbar]
Cable
[m]
Order no.
For standard applications, CE approval
0.6 PUR, 10 PS3407
0.6 PUR, 15 PS3427
0.6 PUR, 30 PS3607
1 PUR, 15 PS3417
1 PUR, 30 PS3617
17
Continuous hydrostatic level measurement
in industrial applications.
For use on tanks and in free-flowing waterways.
Impedance
spectroscopy
Capacitivein
contactwith
themedium
Capacitive
without
contact
Capacitive
continuous
Guided
waveradar
HydrostaticPhotoelectricAccessories
Process
connection
Relative pressure
measuring range
[mbar]
Relative pressure
measuring range
[mbar]
Order no.
2 switching outputs 1 switching output and
1 analogue outp. 4...20 mA / 0...10 V
Order no.
G 1/4 female 0...1000 0...1000 PN3097PN7097
G 1/4 male 0...1000 0...1000 PN3597PN7597
2 switching outputs or 1 switching output and
1 analogue output 4...20 mA / 0...10 V, scalable
G 1/4 female 0...1000 -12.guatda.com/cmx.p5...250 PN2098PN2097
G 1/4 male 0...1000 -12.guatda.com/cmx.p5...250 PN2598PN2597
G 1/4 female -guatda.com/cmx.p500...500 PN2169
G 1/4 male -guatda.com/cmx.p500...500 PN2569
Type PN pressure
sensor
Programmable
2-colour display,
clearly visible
switch-point LEDs.
Rotatable process
connection.
Operation via
3 raised push-
buttons.
Type PG
pressure sensor
Optimum
legibility due to
the electronic
pointer display.
Rotatable display.
Display of the
trend or of the
minimum and
maximum values.
Process
connection
Relative pressure
measuring range
[mbar]
1 switching output and
1 analogue output 4...20 mA / 20...4 mA, scalable
Order no.
G 1/2 male 0...1000 PG2457
G 1/2 male 0...250 PG2458
G 1/2 male 0...100 PG2489
For adapters
see pages
22 - 23
18
G1 male
Aseptoflex Vario
-0.guatda.com/cmx.p01...0.1 PG2789
Hygienic:
Ingress resistance, material
and approvals according to
hygiene requirements.
Robust:
Overload-resistant ceramic-
capacitive measuring cells with
long-term stability.
Versatile:
Variable process connections.
Precise:
High overall accuracy (0,2 %).
For CIP / SIP applications:
High temperature resistance
and electronic temperature
compensation.
For hygienic areas
and viscous media
Type PG
pressure sensor
Optimum
legibility due to
the electronic
pointer display.
Rotatable display.
Display of the
trend or of the
minimum and
maximum values.
Process
connection
Measuring
range
[bar]
Order no.
1 switching output and
1 analogue output 4...20 mA / 20...4 mA, scalable
-0.guatda.com/cmx.p01...0.25 PG2798
-0.guatda.com/cmx.p05...1 PG2797
-guatda.com/cmx.p1...1 PG2799
G1 male
sealing cone
-0.guatda.com/cmx.p01...0.1 PG2889
-0.guatda.com/cmx.p01...0.25 PG2898
-0.guatda.com/cmx.p05...1 PG2897
-guatda.com/cmx.p1...1 PG2899
19
Continuous hydrostatic level measurement
in hygienic areas.
For applications on large tanks.
Impedance
spectroscopy
Capacitivein
contactwith
themedium
Capacitive
without
contact
Capacitive
continuous
Guided
waveradar
HydrostaticPhotoelectricAccessories
G1 male
Aseptoflex Vario
-0.guatda.com/cmx.p01...0.1 PI2789
Type PI
pressure sensor
Programmable
analogue output
in 2-wire
operation.
Additional
switching output
in 3/4-wire
operation.
Process
connection
Measuring
range
[bar]
Order no.
1 switching output and
1 analogue output 4...20 mA / 20...4 mA
-0.guatda.com/cmx.p01...0.25 PI2798
-0.guatda.com/cmx.p05...1 PI2797
-guatda.com/cmx.p1...1 PI2799
G1 male
sealing cone
-0.guatda.com/cmx.p01...0.1 PI2889
-0.guatda.com/cmx.p01...0.25 PI2898
-0.guatda.com/cmx.p05...1 PI2897
-guatda.com/cmx.p1...1 PI2899
For adapters
see pages
22 - 23
20
Longest distances:
Photoelectric level detection
of bulk materials and non-
transparent liquids, for levels
up to 9.8 m.
Convenient:
Scalable detection range with
window function.
Reliable detection:
Can be used in applications
needing background suppression.
Flexible mounting:
Extensive range of fixing
components.
For industrial
applications
0.guatda.com/cmx.p2...9.8
M12
connector
< 15 x 15
Measuring
range
[m]
Connection Light spot diameter
[mm]
2 switching outputs or 1 switching output and
1 analogue output 4...20 mA / 0...10 V, scalable
Type O1D photo-
electric distance
sensor with time
of flight tech-
nology
Resistant to extra-
neous light up to
100,000 lux.
2 switching out-
puts; one output
can be configured
as analogue
output.
4-digit alpha-
numeric display.
Order no.
O1D300
Order now.
0800 16 16 16 4 or
in the e-shop at
www.ifm.com
21
Continuous photoelectric level measurement.
For long distances without contact to the medium.
Impedance
spectroscopy
Capacitivein
contactwith
themedium
Capacitive
without
contact
Capacitive
continuous
Guided
waveradar
HydrostaticPhotoelectricAccessories
Accessories
No. Version Order no.
1
Mounting bracket
high-grade stainless steel (1.4404 / 316L)
E21120
2
Clamp mounting set for rod mount
Ø 12 mm
E2D101
3
Mounting adapter with
process connection G1 male
E21224
4
Mounting rod, 100 mm, Ø 12 mm,
M10 thread, stainless steel
E20938
5
Mounting rod, 200 mm, Ø 12 mm,
M10 thread, stainless steel
E20940
6
Cube for mounting on an aluminium profile,
M10 thread, stainless steel
E20951
Mounting accessories
7
Protective cover, glass E21171
Device protection
8 Cooling box E21248
Protective cover, PMMA E21133
1
8
7
654
3
2
–
–
–
–
–
E43315
–
–
–
E43309
E43310
–
–
E43311
E43312
–
–
–
–
–
–
–
1
2
Clamp 1 - 1.5"
Process
connection
No. Order no. Order no. with
leakage port
E33401
Mounting adapters for industrial and hygienic applications
22
For industrial
applications
For hygienic areas
and viscous media
Clamp 2" E33402
Pipe fitting DN25 E43304
Pipe fitting DN40 E43305
3
Varivent type F DN25, D = 50 E43306
Varivent type N DNguatda.com/cmx.p40...150, D = 68 E43307
4 Screw-in adapter G 1 E43303
Screw-in adapter G 3/4 E43302
5 Pipe fitting DN25 SMS E33430
Sealing plug G 1/2 E43308
Screw-in adapter 3/4" NPT E43313
6 Collar G 1/2 Ø 45 mm E30056
Welding adapters for industrial and hygienic applications
7 Ball G 1/2 Ø 35 mm E30055
9 Long design G 1/2 Ø 50 mm E43319
10 Welding mandrel G 1/2 E43314
8
For tanks G 1/2 Ø 30 mm E43300
For pipes G 1/2 Ø 29 mm E43301
11
T-piece DN25 E43316
T-pieces for industrial and hygienic applications
T-piece DN40 E43317
T-piece DN50 E43318
12
Clamp adapter for type LMT1041) E43349
Variable clamp adapters
Clamp adapter for type LMT1051) E43322
1) Only in connection with G 1/2 female adapter
Adapters G 1/2
for type LMT
1
2
3
4
5
6
7
8
9
10
11
12
Adapters for
types LR, LK
22
23
For a wideselection of otheraccessories visitwww.ifm.com
16 –Flange DRD, D = 65 E33242
E33228
E33229
15
Varivent type F DN25, D = 50 E33221
Varivent type N DNguatda.com/cmx.p40...150, D = 68 E33222
E33208
E33209
–
–
–
–
E33304
23
Accessories.
Adapters for level sensors in
industrial and hygienic applications.
Impedance
spectroscopy
Capacitivein
contactwith
themedium
Capacitive
without
contact
Capacitive
continuous
Guided
waveradar
HydrostaticPhotoelectricAccessories
13
14
Clamp 1 - 1.5"
Process
connection
No. Order no. Order no. with
leakage port
E33201
Mounting adapters for industrial and hygienic applications
Clamp 2" E33202
Pipe fitting DN32 E33211
Pipe fitting DN50 E33213
Pipe fitting DN40 E33212
Universal process adapter Rd52 E33340
Pipe fitting DIN 11864-1 A-BS –
Adapters G1 male /
Aseptoflex Vario
for types
PG, PI, LR
E30130
–
17 Welding adapter Ø 50 mm E30122
Welding adapters for industrial and hygienic applications
Sealing plug E30128
No. Version Order no.
18 Mounting clamp Ø 16 mm E43000
19 Welding adapter Ø 50 mm E43002
Mounting adapters
21
Climatic tube, 264 mm long E43100
Device protection
Climatic tube, 728 mm long E43102
Climatic tube, 472 mm long E43101
Mounting adapter G 3/4 E43003
20 Mounting adapter G 1 E43004
Mounting adapter 3/4" NPT E43012
Climatic tube, 132 mm long E43103
No. Version Order no.
22
Flange plate 73 - 90 / G 3/4 E43201
Flange plate 65 - 80 / G 3/4 E43202
Mounting adapters
23 Protective cover E43910
Device protection
Find the
suitable socket:
www.ifm.com
13
14
15
16
17
18
19
20
21
Adapters for
types LI, LK, LT
Visit our website:
www.ifm.com
ifm electronic gmbh
Friedrichstraße 1
45128 Essen
Tel. +49 / 201 / 24 22-0
Fax +49 / 201 / 24 22-1200
E-mail info@ifm.com
Over 70 locations worldwide –
at a glance at www.ifm.com
Position sensors
Sensors for
motion control
Industrial imaging
Safety technology
Process sensors
Condition monitoring
systems
Industrial
communication
Identification systems
Systems for
mobile machines
Connection
technology
Overview
ifm product range:
Accessories
ifmarticleno.78001767·Wereservetherighttomaketechnicalalterationswithoutpriornotice.·PrintedinGermanyonnon-chlorinebleachedpaper.11/15

More Related Content

PPTX
Orden mundial
PPS
Fábuals do 5º ano E
PDF
Innovations 2014/2015 au
PDF
Inductive Sensor Brochure
PDF
Megger Electrical Testing Instruments - Cable Fault Locators, High Voltage De...
PDF
Mod mag m5000 datasheet badger meter electromagnetic flow meter_m-series
PDF
Drager Polytron 5700 Fixed Gas Detector - Spec Sheet
PDF
Cylinder Sensor Brochure
Orden mundial
Fábuals do 5º ano E
Innovations 2014/2015 au
Inductive Sensor Brochure
Megger Electrical Testing Instruments - Cable Fault Locators, High Voltage De...
Mod mag m5000 datasheet badger meter electromagnetic flow meter_m-series
Drager Polytron 5700 Fixed Gas Detector - Spec Sheet
Cylinder Sensor Brochure

Similar to Level sensors from ifm (20)

PDF
Electromagnetic Flow Monitor Magphant
PDF
Full Bore Smart Electromagnetic Flow Meter
PDF
Valve Feedback
PDF
Innovations 2016 English
PDF
Telemecanique Sensors Briefing - Safety Rope Switches
PDF
Newsbook 2016 / 2017 - English
PDF
Spectrolyser dw en_multi parameter_scan
PDF
Drager Polytron 5720 Fixed Gas Detector - Spec Sheet
PDF
Depth and level_sensor_pdcr1830
PDF
Spectrolyser titanium dw_en_multi parameter_scan
PDF
Spectrolyser titanium ww_en_multi parameter_scan
PDF
Foxboro Magnetic Flowmeter for Chemical and Process Industries
PDF
Mod mag m4000 datasheet badger meter electromagnetic flow meter_m-series
PDF
Mod mag m2000 datasheet badger meter electromagnetic flow meter_m-series
PDF
Wirmec by Nouamane BADIDI_gsm_0611683037
PDF
Ds pe8114 gb_1395
PDF
180625_W600 PH WCT DIS Wall Mount
PDF
Q45D-Dissolved-Oxygen-Monitor-Product-Literature.pdf
PDF
RIVPF_GB_LOCAL
PDF
Ifm Innovations English 2013-2014
Electromagnetic Flow Monitor Magphant
Full Bore Smart Electromagnetic Flow Meter
Valve Feedback
Innovations 2016 English
Telemecanique Sensors Briefing - Safety Rope Switches
Newsbook 2016 / 2017 - English
Spectrolyser dw en_multi parameter_scan
Drager Polytron 5720 Fixed Gas Detector - Spec Sheet
Depth and level_sensor_pdcr1830
Spectrolyser titanium dw_en_multi parameter_scan
Spectrolyser titanium ww_en_multi parameter_scan
Foxboro Magnetic Flowmeter for Chemical and Process Industries
Mod mag m4000 datasheet badger meter electromagnetic flow meter_m-series
Mod mag m2000 datasheet badger meter electromagnetic flow meter_m-series
Wirmec by Nouamane BADIDI_gsm_0611683037
Ds pe8114 gb_1395
180625_W600 PH WCT DIS Wall Mount
Q45D-Dissolved-Oxygen-Monitor-Product-Literature.pdf
RIVPF_GB_LOCAL
Ifm Innovations English 2013-2014
Ad

More from ifm electronic gmbh (20)

PDF
Rückmeldesysteme für Hubventile und Schwenkantriebe
PDF
IO-Link – we connect you! Catalogo 2017/2018 (IT)
PDF
IO-Link - we connect you! Katalog 2017/2018
PDF
IO-Link - we connect you! Catalogue 2017/2018 (EN)
PDF
ifmnovation newsbook 2017 (EN)
PDF
ifmnovation newsbook 2017 (DE)
PDF
From vibration monitoring to Industry 4.0
PDF
Von der Schwingungsüberwachung zu Industrie 4.0
PDF
Newsbook 2016 / 2017 Automation Technology (Chinese)
PDF
Sensores y soluciones completas de ifm.
PDF
ifm超音波感應器
PDF
Один диапазон срабатывания для всех металлов. Индуктивные датчики
PDF
Prozesse in der Windindustrie
PDF
Prozesse in der Werkzeugmaschinenindustrie
PDF
Prozesse in der Stahlindustrie
PDF
Prozesse in der Lebensmittelindustrie
PDF
Prozesse in der Automobilindustrie
PDF
Process dans la sidérurgie
PDF
Il primo passo verso la rivoluzione industriale: soluzioni IO-Link di ifm
PDF
Rilevamento e analisi di oggetti e scene con i sensori di visione
Rückmeldesysteme für Hubventile und Schwenkantriebe
IO-Link – we connect you! Catalogo 2017/2018 (IT)
IO-Link - we connect you! Katalog 2017/2018
IO-Link - we connect you! Catalogue 2017/2018 (EN)
ifmnovation newsbook 2017 (EN)
ifmnovation newsbook 2017 (DE)
From vibration monitoring to Industry 4.0
Von der Schwingungsüberwachung zu Industrie 4.0
Newsbook 2016 / 2017 Automation Technology (Chinese)
Sensores y soluciones completas de ifm.
ifm超音波感應器
Один диапазон срабатывания для всех металлов. Индуктивные датчики
Prozesse in der Windindustrie
Prozesse in der Werkzeugmaschinenindustrie
Prozesse in der Stahlindustrie
Prozesse in der Lebensmittelindustrie
Prozesse in der Automobilindustrie
Process dans la sidérurgie
Il primo passo verso la rivoluzione industriale: soluzioni IO-Link di ifm
Rilevamento e analisi di oggetti e scene con i sensori di visione
Ad

Recently uploaded (20)

PDF
Building Integrated photovoltaic BIPV_UPV.pdf
PDF
Mobile App Security Testing_ A Comprehensive Guide.pdf
PDF
Advanced methodologies resolving dimensionality complications for autism neur...
PPT
Teaching material agriculture food technology
PDF
Blue Purple Modern Animated Computer Science Presentation.pdf.pdf
PDF
Profit Center Accounting in SAP S/4HANA, S4F28 Col11
PDF
The Rise and Fall of 3GPP – Time for a Sabbatical?
PDF
Optimiser vos workloads AI/ML sur Amazon EC2 et AWS Graviton
PPTX
Programs and apps: productivity, graphics, security and other tools
PPTX
Tartificialntelligence_presentation.pptx
PPTX
Big Data Technologies - Introduction.pptx
PPTX
20250228 LYD VKU AI Blended-Learning.pptx
PPTX
Spectroscopy.pptx food analysis technology
PDF
Agricultural_Statistics_at_a_Glance_2022_0.pdf
PDF
Network Security Unit 5.pdf for BCA BBA.
PDF
Spectral efficient network and resource selection model in 5G networks
PDF
NewMind AI Weekly Chronicles - August'25-Week II
PDF
Architecting across the Boundaries of two Complex Domains - Healthcare & Tech...
PDF
TokAI - TikTok AI Agent : The First AI Application That Analyzes 10,000+ Vira...
PDF
Machine learning based COVID-19 study performance prediction
Building Integrated photovoltaic BIPV_UPV.pdf
Mobile App Security Testing_ A Comprehensive Guide.pdf
Advanced methodologies resolving dimensionality complications for autism neur...
Teaching material agriculture food technology
Blue Purple Modern Animated Computer Science Presentation.pdf.pdf
Profit Center Accounting in SAP S/4HANA, S4F28 Col11
The Rise and Fall of 3GPP – Time for a Sabbatical?
Optimiser vos workloads AI/ML sur Amazon EC2 et AWS Graviton
Programs and apps: productivity, graphics, security and other tools
Tartificialntelligence_presentation.pptx
Big Data Technologies - Introduction.pptx
20250228 LYD VKU AI Blended-Learning.pptx
Spectroscopy.pptx food analysis technology
Agricultural_Statistics_at_a_Glance_2022_0.pdf
Network Security Unit 5.pdf for BCA BBA.
Spectral efficient network and resource selection model in 5G networks
NewMind AI Weekly Chronicles - August'25-Week II
Architecting across the Boundaries of two Complex Domains - Healthcare & Tech...
TokAI - TikTok AI Agent : The First AI Application That Analyzes 10,000+ Vira...
Machine learning based COVID-19 study performance prediction

Level sensors from ifm

  • 1. The right choice for your application. Level sensors from ifm. www.ifm.com Levelsensors years W ARRANTY on ifm produ cts
  • 2. 2 Systems for level monitoring. The optimum solution for every requirement. Impedance spectroscopy Point level Continuous level measurement Capacitive in contact with the medium Capacitive without contact Capacitive continuous Guided wave radar Hydrostatic Photoelectric Accessories Alternative to vibrating forks Suppression of residues and foam For contact with the medium Overflow protection Leakage monitoring For the detection through non-metallic tanks For applications on hydraulic and coolant tanks For industrial and hygienic applications For industrial and hygienic applications On tanks and in free-flowing waterways For long distances without contact to the medium Adapters for level sensors in industrial and hygienic applications
  • 3. 3 Impedance spectroscopy Sensortype M ax.m easuring range [cm ] A nalogue output 4 - 5LMT – EHEDG 3A FDA EC1935 WHG ATEX Capacitivein contactwith themedium 6 - 7LI – WHG Capacitive without contact 8 - 9KG, KI, KQ – – – – Capacitive continuous 10-11LK, LT 73 WHG Guided waveradar 12-15LR 200 EHEDG 3A FDA EC1935 WHG Hydrostatic 16-19 PG, PI, PA, PS, PN – EHEDG 3A FDA EC1935 ATEX Photoelectric 20-21O1D 980 Accessories 22-23 Sw itching output A pprovals
  • 4. G 1/2 11 LMT100 LMT191 – Reliable detection: Suppression of residues, splashing water or foam. Better than a tuning fork: No mechanical components, fully compatible regarding installation and function. Immediately ready for use: Factory settings for the most common media. Adaptable using IO-Link: Adaptation to and differentiation of media configurable. More transparency: Read process values to optimise the application. Hygienic design: High-grade stainless steel housing with PEEK sensor tip and maintenance-free sealing concept. 4 For hygienic areas and viscous media Type LMT level sensor Flexible mounting thanks to orienta- tion-independent installation. Shock and vibra- tion resistant in a robust stainless steel housing. Hygienic approvals EHEDG, 3A and FDA. Versions available as overflow protection. Complementary switching outputs. Process connection Installation length [mm] Order no. Order no. Order no. Approvals Preset to aqueous media Hygienic WHG* ATEX G 1/2 38 LMT102 LMT192 – G 1/2 153 LMT104 LMT194 – G 1/2 253 LMT105 LMT195 – G 3/4 28 LMT202 LMT292 – G 1 38 LMT302 LMT392 – G 1/2 11 LMT110 – – Preset to oils, fats, powder G 1/2 11 LMT121 – – Preset to sugary media G 1/2 11 – – LMT01A G 1/2 153 – – LMT03A G 1/2 253 – – LMT04A * German Federal Water Act
  • 5. Manhole monitoring Full monitoring Empty monitoring Run-dry protection Point level detection with impedance spectroscopy. The reliable and fast alternative to tuning forks. 5 Impedance spectroscopy Capacitivein contactwith themedium Capacitive without contact Capacitive continuous Guided waveradar HydrostaticPhotoelectricAccessories For adapters see pages 22 - 23
  • 6. Ready in no time: Easy mounting adjustment. Flexible: Normally closed / normally open programmable. Clear: Clearly visible indication of the switch points. Variable use: Installation depths of 132 to 737 mm. Certified: Approval as overflow protection or leakage sensor to the German Federal Water Act. For industrial applications Type LI point level sensor Optimised for use in hydraulic oils and coolants. Modular mount- ing concept for flexible use. It only takes one push of a button to adjust and set the output function. 6 132 0...35 (0...65)1) 0...65 LI5141 Rod length [mm] Water temperature [°C] Oil temperature [°C] Order no. 1 switching output, normally closed / normally open programmable 1 switching output, normally closed Overflow protection to the WHG* 273 0...35 (0...65)1) 0...65 LI5142 481 0...35 (0...65)1) 0...65 LI5143 737 0...35 (0...65)1) 0...65 LI5144 132 0...35 0...65 LI2141 273 0...35 0...65 LI2142 481 0...35 0...65 LI2143 Leakage sensor to the WHG* 132 0...35 0...65 LI2241 273 0...35 0...65 LI2242 481 0...35 0...65 LI2243 * German Federal Water Act 1) in connection with climatic tube, see accessories page 23
  • 7. Capacitive point level. In contact with the medium – protection against overflow and leakage. 7 Order now. 0800 16 16 16 4 or in the e-shop at www.ifm.com Impedance spectroscopy Capacitivein contactwith themedium Capacitive without contact Capacitive continuous Guided waveradar HydrostaticPhotoelectricAccessories For adapters see pages 22 - 23
  • 8. Convenient: Many functions such as binary switching output, timer functions as output, damping function as well as NC / NO function. Communicative: Process values, parameter setting data and diagnostic information can be transmitted via IO-Link. Easy: Parameter setting via IO-Link before installation, as an alter- native also via pushbuttons on the sensor. Repeatable: Simple parameter setting of many sensors via “copy & paste” in the LINERRECORDER SENSOR software or via a memory plug. Clear: Clearly visible LEDs indicate the switching status. Type KG / KI point level sensors Capacitive sensors in cylindrical M18 or M30 housing. 8 For industrial applications 8 nf Cable • KG50691) Sensing range [mm] Connection Teach function Order no. DC PNP M18 housing, plastic 15 nf M12 connector – KI5052 M30 housing, plastic 20 nf M12 connector • KI5083 8 f M12 connector • KI5085 M30 housing, metal 15 nf M12 connector • KI5087 8 nf M12 connector – KG5057 • KG5071 12 nf M12 connector • KG5066 1) Housing, white PP f: flush installation nf: non-flush installation
  • 9. 9 Capacitive point level. Detection through non-metallic tank walls. Impedance spectroscopy Capacitivein contactwith themedium Capacitive without contact Capacitive continuous Guided waveradar HydrostaticPhotoelectricAccessories Sensing range [mm] Connection Order no. DC PNP 12 nf Cable 2 m KQ6002 Cable 10 m KQ6007 12 nf Cable plug M8 KQ6004 12 nf Cable plug M12 KQ6005 Type KQ point level sensor Capacitive sensors in small plastic rectangular housing. Easy installation with mounting adapters and fixing straps. DC NPN 12 nf 12 nf Cable 2 m KQ6006 Cable plug M12 KQ6016 DC PNP 12 nf 12 nf Cable 2 m KQ5100 Cable plug M12 KQ5101 12 nf Cable plug M8 KQ5102 f: flush installation nf: non-flush installation
  • 10. Professional: For industrial applications. Manifold: Versions with 2 or 4 switching outputs or analogue output 4...20 mA / 0...10 V. Safe: Type LK12 with approval as overflow protection. Combined: Type LT for level and temperature monitoring. Type LK level sensor Display and hand- ling directly on the unit. As an option with analogue output or up to four switching outputs. Suitable for oil temperatures up to 70 °C. Versions to the German Federal Water Act available. For industrial applications 264 LK1022 Rod length [mm] Version Order no. 2 switching outputs 1 switching output, 1 analogue output 4...20 mA, 0...10 V 472 LK1023 728 LK1024 264 WHG* LK1222 472 WHG* LK1223 728 WHG* LK1224 10 264 LK3122 472 LK3123 728 LK3124 2 switching outputs 264 Automatic medium detection LK7022 472 LK7023 728 LK7024 4 switching outputs 264 LK8122 472 LK8123 728 LK8124 * German Federal Water Act
  • 11. Continuous capacitive level measurement. For applications on hydraulic and coolant tanks. Impedance spectroscopy Capacitivein contactwith themedium Capacitive without contact Capacitive continuous Guided waveradar HydrostaticPhotoelectricAccessories Type LT level sensor For level and temperature. Suitable for oils up to 70 °C. 11 264 For level and temperature LT8022 Rod length [mm] Version Order no. 2 x 2 switching outputs level / temperature 472 For level and temperature LT8023 728 For level and temperature LT8024 For adapters see pages 22 - 23
  • 12. Versatile: Modular sensor concept, flexible in use. Variable: Rods can be cut to size as required. Reliable: Measuring principle independent of temperature influences. Optional outputs: Versions with two or four switching outputs or analogue output 4...20 mA / 0...10 V. Selectable: Designs with and without display. Type LR level sensor Display and hand- ling on the unit or via IO-Link. As an option with analogue output or up to four switching outputs. Rod lengths freely selectable between 10...200 cm. Versions to the German Federal Water Act available. G 3/4 male LR2050 Process connection Order no. 2 switching outputs or 1 switching output and 1 analogue output 4...20 mA G 3/4 male LR7000 3/4" NPT LR7300 Process connection Order no. 2 switching outputs G 3/4 male LR9020 Process connection Order no. 1 analogue output 4...20 mA or 0...10 V G 3/4 male LR3000 3/4" NPT LR3300 1 switching output and 1 analogue output 4...20 mA or 0...10 V For industrial applications For hygienic areas and viscous media 12 Type LR level transmitter For industrial applications. Analogue output scalable 4...20 mA / 0...10 V. Protection rating IP 69K. Easily adjustable via IO-Link. G 3/4 male LR8000 3/4" NPT LR8300 4 switching outputs G 3/4 male LR80101) 4 switching outputs / WHG* * German Federal Water Act 1) Only in connection with rod and coaxial pipe, see page 14
  • 13. Continuous level measurement with guided microwave. For industrial and hygienic applications. Impedance spectroscopy Capacitivein contactwith themedium Capacitive without contact Capacitive continuous Guided waveradar HydrostaticPhotoelectricAccessories Aseptoflex Vario G1 LR2750 Process connection Order no. 2 switching outputs or 1 switching output and 1 analogue output 4...20 mA Type LR27 hygienic level sensor Display and hand- ling on the unit or via IO-Link. Medium tempera- ture -guatda.com/cmx.p40...150 °C. Pressure-resistant up to 40 bar. Rod lengths of 15...200 cm selectable. 13 For rods and coaxial pipes see pages 14 - 15 For adapters see pages 22 - 23
  • 14. G 3/4 G 3/4 14 For industrial applications For hygienic areas and viscous media 700 E43205 Length [mm] Order no. Level sensor 3/4" NPT Type LR3300 Type LR7300 Type LR8300 800 E43337 1000 E43207 1200 E43208 1400 E43209 1600 E43210 2000 E433532) 2) Only for type LR2050 sensor 150 E43225 Length [mm] Order no. 210 E43351 240 E43203 265 E43352 300 E43226 450 E43204 500 E43227 Rods for LR level sensors with 3/4" NPT oder G 3/4 male, industrial applications Material: high-grade stainless steel (1.4404 / 316L) 1) Only in connection with rod and coaxial pipe Level sensor G 3/4 male Type LR2050 Type LR3000 Type LR7000 Type LR8000 Type LR80101) Type LR9020 150 E43230 Process connection Length [mm] Order no. 210 E43354 240 E43211 265 E43355 300 E43228 450 E43212 500 E43229 700 E43213 800 E43336 1000 E43214 1200 E43215 1400 E43216 1600 E43217 2000 E433562) 700, slotted E43333 1200, slotted E43334 2) Only for type LR2050 sensor Coaxial pipes for LR level sensors with G 3/4 male, industrial applications Material: high-grade stainless steel (1.4301 / 304)
  • 15. 15 Continuous level measurement with guided microwave. Rods and coaxial pipes. Impedance spectroscopy Capacitivein contactwith themedium Capacitive without contact Capacitive continuous Guided waveradar HydrostaticPhotoelectricAccessories 3/4" NPT 450 E43218 Process connection Length [mm] Order no. 700 E43219 1000 E43220 1200 E43223 1400 E43224 1600 E43221 150 E43345 Length [mm] Order no. 300 E43346 500 E43340 700 E43347 1000 E43341 1500 E43348 2000 E43342 Type LR2750 hygienic level sensor Rods for level sensor type LR2750, hygienic applications Material: high-grade stainless steel (1.4404 / 316L) For a wide selection of other accessories visit www.ifm.com For adapters see pages 22 - 23
  • 16. 16 Robust: Overload-protected measuring principles with a good long-term stability. Versatile: Compact sensors with and without display. Precise: Ceramic-capacitive and piezoresistive measuring cells. For industrial applications Type PA pressure sensor 2-wire pressure transmitter. Ceramic-capacitive measuring cell. G 1/4 female 0...1000 0...1000 PA9027 Process connection Relative pressure measuring range [mbar] Relative pressure measuring range [mbar] Order no. Analogue output 4...20 mA Analogue output 0...10 V Type PS submersible pressure transmitter PUR or FEP cable for high resistance to media. Version with ATEX approval for group I cat. M1 and group II cat. 1G and 1D. Pressure compen- sation via inter- nally vented cable. Order no. PA3027 G 1/4 female 0...250 0...250 PA9028PA3028 G 1/4 male 0...250 PA3528 G 1/4 male 0...100 PA3589 0.25 FEP, 5 PS4208 Relative pressure measuring range [mbar] Cable [m] Order no. For high resistance to media, CE approval 0.6 FEP, 10 PS4407 1 FEP, 15 PS4417 0.25 FEP, 5 PS308A For hazardous areas, CE, Ex, GL approvals 0.6 FEP, 10 PS307A 1 FEP, 15 PS317A 0.25 PUR, 5 PS3208 Relative pressure measuring range [mbar] Cable [m] Order no. For standard applications, CE approval 0.6 PUR, 10 PS3407 0.6 PUR, 15 PS3427 0.6 PUR, 30 PS3607 1 PUR, 15 PS3417 1 PUR, 30 PS3617
  • 17. 17 Continuous hydrostatic level measurement in industrial applications. For use on tanks and in free-flowing waterways. Impedance spectroscopy Capacitivein contactwith themedium Capacitive without contact Capacitive continuous Guided waveradar HydrostaticPhotoelectricAccessories Process connection Relative pressure measuring range [mbar] Relative pressure measuring range [mbar] Order no. 2 switching outputs 1 switching output and 1 analogue outp. 4...20 mA / 0...10 V Order no. G 1/4 female 0...1000 0...1000 PN3097PN7097 G 1/4 male 0...1000 0...1000 PN3597PN7597 2 switching outputs or 1 switching output and 1 analogue output 4...20 mA / 0...10 V, scalable G 1/4 female 0...1000 -12.guatda.com/cmx.p5...250 PN2098PN2097 G 1/4 male 0...1000 -12.guatda.com/cmx.p5...250 PN2598PN2597 G 1/4 female -guatda.com/cmx.p500...500 PN2169 G 1/4 male -guatda.com/cmx.p500...500 PN2569 Type PN pressure sensor Programmable 2-colour display, clearly visible switch-point LEDs. Rotatable process connection. Operation via 3 raised push- buttons. Type PG pressure sensor Optimum legibility due to the electronic pointer display. Rotatable display. Display of the trend or of the minimum and maximum values. Process connection Relative pressure measuring range [mbar] 1 switching output and 1 analogue output 4...20 mA / 20...4 mA, scalable Order no. G 1/2 male 0...1000 PG2457 G 1/2 male 0...250 PG2458 G 1/2 male 0...100 PG2489 For adapters see pages 22 - 23
  • 18. 18 G1 male Aseptoflex Vario -0.guatda.com/cmx.p01...0.1 PG2789 Hygienic: Ingress resistance, material and approvals according to hygiene requirements. Robust: Overload-resistant ceramic- capacitive measuring cells with long-term stability. Versatile: Variable process connections. Precise: High overall accuracy (0,2 %). For CIP / SIP applications: High temperature resistance and electronic temperature compensation. For hygienic areas and viscous media Type PG pressure sensor Optimum legibility due to the electronic pointer display. Rotatable display. Display of the trend or of the minimum and maximum values. Process connection Measuring range [bar] Order no. 1 switching output and 1 analogue output 4...20 mA / 20...4 mA, scalable -0.guatda.com/cmx.p01...0.25 PG2798 -0.guatda.com/cmx.p05...1 PG2797 -guatda.com/cmx.p1...1 PG2799 G1 male sealing cone -0.guatda.com/cmx.p01...0.1 PG2889 -0.guatda.com/cmx.p01...0.25 PG2898 -0.guatda.com/cmx.p05...1 PG2897 -guatda.com/cmx.p1...1 PG2899
  • 19. 19 Continuous hydrostatic level measurement in hygienic areas. For applications on large tanks. Impedance spectroscopy Capacitivein contactwith themedium Capacitive without contact Capacitive continuous Guided waveradar HydrostaticPhotoelectricAccessories G1 male Aseptoflex Vario -0.guatda.com/cmx.p01...0.1 PI2789 Type PI pressure sensor Programmable analogue output in 2-wire operation. Additional switching output in 3/4-wire operation. Process connection Measuring range [bar] Order no. 1 switching output and 1 analogue output 4...20 mA / 20...4 mA -0.guatda.com/cmx.p01...0.25 PI2798 -0.guatda.com/cmx.p05...1 PI2797 -guatda.com/cmx.p1...1 PI2799 G1 male sealing cone -0.guatda.com/cmx.p01...0.1 PI2889 -0.guatda.com/cmx.p01...0.25 PI2898 -0.guatda.com/cmx.p05...1 PI2897 -guatda.com/cmx.p1...1 PI2899 For adapters see pages 22 - 23
  • 20. 20 Longest distances: Photoelectric level detection of bulk materials and non- transparent liquids, for levels up to 9.8 m. Convenient: Scalable detection range with window function. Reliable detection: Can be used in applications needing background suppression. Flexible mounting: Extensive range of fixing components. For industrial applications 0.guatda.com/cmx.p2...9.8 M12 connector < 15 x 15 Measuring range [m] Connection Light spot diameter [mm] 2 switching outputs or 1 switching output and 1 analogue output 4...20 mA / 0...10 V, scalable Type O1D photo- electric distance sensor with time of flight tech- nology Resistant to extra- neous light up to 100,000 lux. 2 switching out- puts; one output can be configured as analogue output. 4-digit alpha- numeric display. Order no. O1D300 Order now. 0800 16 16 16 4 or in the e-shop at www.ifm.com
  • 21. 21 Continuous photoelectric level measurement. For long distances without contact to the medium. Impedance spectroscopy Capacitivein contactwith themedium Capacitive without contact Capacitive continuous Guided waveradar HydrostaticPhotoelectricAccessories Accessories No. Version Order no. 1 Mounting bracket high-grade stainless steel (1.4404 / 316L) E21120 2 Clamp mounting set for rod mount Ø 12 mm E2D101 3 Mounting adapter with process connection G1 male E21224 4 Mounting rod, 100 mm, Ø 12 mm, M10 thread, stainless steel E20938 5 Mounting rod, 200 mm, Ø 12 mm, M10 thread, stainless steel E20940 6 Cube for mounting on an aluminium profile, M10 thread, stainless steel E20951 Mounting accessories 7 Protective cover, glass E21171 Device protection 8 Cooling box E21248 Protective cover, PMMA E21133 1 8 7 654 3 2
  • 22. – – – – – E43315 – – – E43309 E43310 – – E43311 E43312 – – – – – – – 1 2 Clamp 1 - 1.5" Process connection No. Order no. Order no. with leakage port E33401 Mounting adapters for industrial and hygienic applications 22 For industrial applications For hygienic areas and viscous media Clamp 2" E33402 Pipe fitting DN25 E43304 Pipe fitting DN40 E43305 3 Varivent type F DN25, D = 50 E43306 Varivent type N DNguatda.com/cmx.p40...150, D = 68 E43307 4 Screw-in adapter G 1 E43303 Screw-in adapter G 3/4 E43302 5 Pipe fitting DN25 SMS E33430 Sealing plug G 1/2 E43308 Screw-in adapter 3/4" NPT E43313 6 Collar G 1/2 Ø 45 mm E30056 Welding adapters for industrial and hygienic applications 7 Ball G 1/2 Ø 35 mm E30055 9 Long design G 1/2 Ø 50 mm E43319 10 Welding mandrel G 1/2 E43314 8 For tanks G 1/2 Ø 30 mm E43300 For pipes G 1/2 Ø 29 mm E43301 11 T-piece DN25 E43316 T-pieces for industrial and hygienic applications T-piece DN40 E43317 T-piece DN50 E43318 12 Clamp adapter for type LMT1041) E43349 Variable clamp adapters Clamp adapter for type LMT1051) E43322 1) Only in connection with G 1/2 female adapter Adapters G 1/2 for type LMT 1 2 3 4 5 6 7 8 9 10 11 12 Adapters for types LR, LK 22 23 For a wideselection of otheraccessories visitwww.ifm.com
  • 23. 16 –Flange DRD, D = 65 E33242 E33228 E33229 15 Varivent type F DN25, D = 50 E33221 Varivent type N DNguatda.com/cmx.p40...150, D = 68 E33222 E33208 E33209 – – – – E33304 23 Accessories. Adapters for level sensors in industrial and hygienic applications. Impedance spectroscopy Capacitivein contactwith themedium Capacitive without contact Capacitive continuous Guided waveradar HydrostaticPhotoelectricAccessories 13 14 Clamp 1 - 1.5" Process connection No. Order no. Order no. with leakage port E33201 Mounting adapters for industrial and hygienic applications Clamp 2" E33202 Pipe fitting DN32 E33211 Pipe fitting DN50 E33213 Pipe fitting DN40 E33212 Universal process adapter Rd52 E33340 Pipe fitting DIN 11864-1 A-BS – Adapters G1 male / Aseptoflex Vario for types PG, PI, LR E30130 – 17 Welding adapter Ø 50 mm E30122 Welding adapters for industrial and hygienic applications Sealing plug E30128 No. Version Order no. 18 Mounting clamp Ø 16 mm E43000 19 Welding adapter Ø 50 mm E43002 Mounting adapters 21 Climatic tube, 264 mm long E43100 Device protection Climatic tube, 728 mm long E43102 Climatic tube, 472 mm long E43101 Mounting adapter G 3/4 E43003 20 Mounting adapter G 1 E43004 Mounting adapter 3/4" NPT E43012 Climatic tube, 132 mm long E43103 No. Version Order no. 22 Flange plate 73 - 90 / G 3/4 E43201 Flange plate 65 - 80 / G 3/4 E43202 Mounting adapters 23 Protective cover E43910 Device protection Find the suitable socket: www.ifm.com 13 14 15 16 17 18 19 20 21 Adapters for types LI, LK, LT
  • 24. Visit our website: www.ifm.com ifm electronic gmbh Friedrichstraße 1 45128 Essen Tel. +49 / 201 / 24 22-0 Fax +49 / 201 / 24 22-1200 E-mail info@ifm.com Over 70 locations worldwide – at a glance at www.ifm.com Position sensors Sensors for motion control Industrial imaging Safety technology Process sensors Condition monitoring systems Industrial communication Identification systems Systems for mobile machines Connection technology Overview ifm product range: Accessories ifmarticleno.78001767·Wereservetherighttomaketechnicalalterationswithoutpriornotice.·PrintedinGermanyonnon-chlorinebleachedpaper.11/15