g
1 8 3 0 / 1 8 4 0 S e r i e s
High Performance Level Pressure Sensors
Ⅲ Ranges from 0.75 mH20 to 600 mH20
Ⅲ Accuracy ‫%60.0ע‬
Ⅲ Fully welded 17.5 mm titanium construction
Ⅲ Integral lightning surge arrestor
Ⅲ Polyurethane and hydrocarbon resistant cables
Ⅲ Full range of installation accessories
ADVANCED PRESSURE SENSORS FOR A
WORLD OF LEVEL MEASUREMENTS
Established in 1972, GE Druck specialises in the manufacture of high
performance pressure measurement and related control equipment.
The PDCR 1830/1840 transducer (mV output) and PTX 1830/1840
transmitter (4-20 mA output) are the latest generation of fully
submersible high performance sensors for measurement of hydrostatic
liquid levels.
The PDCR/PTX 1830/1840 series incorporates many enhanced features
gained from Druck’s experience in supplying thousands of sensors for
small and large scale installations worldwide. Example applications
include:
ⅷ Potable Water
From ground water borehole to surface water level measurements in
rivers, canals and reservoirs.
ⅷ Waste Water and Remediation
Monitoring of secondary and outflow sewage levels within certified
hazardous areas and contaminated ground water levels in land fill
sites.
ⅷ Tank Level
From land based liquid storage vessels to on-board ship ballast tank
monitoring within safe and certified hazardous areas, using potable
water approved (1830) cable and hydrocarbon resistant (1840) cable.
ⅷ Sea Water
Marine environmental applications including tide gauging,
coastal/flood protection and wave profiling amongst others.
Reliability and Data Quality
The combination of a high technology sensor, together with advanced
signal conditioning and packaging techniques, provides an ideal long-
term solution for reliable, accurate and economical level measurements.
The GE Druck micromachined silicon element is sealed within an all-
titanium pressure module assembly, fully isolated from the pressure
media. This is contained in a slimline, welded titanium body, terminated
in an injection moulded cable assembly. The cable features a kevlar
strain cord and is IP68 rated for indefinite immersion in 700 mH2O, with
selection of cable material to meet the application.
Lightning Surge Protection
An optional integral lightning surge arrestor is available, qualified to the
highest European standard IEC 61000-4-5 (level 4). This protects the
sensor from raised earth potentials caused by lightning strikes, which
often occur in surface water applications.
Ease of Use
A simple datum marked cable system is provided for ease of
installation. Incremental 1 m datum points are clearly marked for quick
and accurate alignment below ground level. In addition, a full range of
related accessories simplifies installation, operation and maintenance.
ⅷ Quick-release cable clamp assembly
ⅷ Slimline and short profile sink weights
ⅷ Moistureproof Sensor Termination Enclosure
ⅷ In-situ pressure test/calibration adaptors
P D C R / P T X 1 8 3 0 / 1 8 4 0 S e r i e s
High Performance Level Pressure Sensors
STANDARD SPECIFICATIONS
Pressure Measurement
Operating Pressure Ranges
PDCR 1830/1840 (mV)
0.75, 1.5 mH2O gauge, 3.5, 7, 10, 15, 20, 35, 50, 70, 100, 150, 200, 350,
600 mH2O gauge and absolute
PTX 1830/1840 (mA)
Any zero based full scale (FS) from 0.75 to 600 mH2O gauge.
3.5 to 600 mH2O absolute.
Elevated zero, compound and reversed output ranges available.
Refer to GE Druck for further information.
Other units may be specified e.g. ftH2O, InH2O, bar, mbar, psi, kpa, kg/cm
2
Overpressure
The operating FS pressure range may be exceeded by the following
multiples with negligible effect on calibration:
8 x for ranges up to 1.5 mH2O
6 x for ranges above 1.5 mH2O to 3.5 mH2O
4 x for ranges above 3.5 mH2O (1400 mH2O max.)
Pressure Containment
10 x for ranges up to 3.5 mH2O gauge
6 x for ranges above 3.5 mH2O gauge (1400 mH2O max.)
200 bar for absolute ranges.
Media Compatibility
Fluids compatible with titanium (body), acetal (nose cone) and
polyurethane or Hytrel 6108 (cable assembly).
Excitation Voltage
PDCR 1830/1840 (mV)
10 V at 5 mA nominal
Output is fully ratiometric to supply within 2.5 V to 12 V limits.
PTX 1830/1840 (mA)
9 to 30 V
9 to 28 V for Intrinsically Safe version.
The minimum supply voltage (VMIN) which must appear across the
pressure transmitter terminals is 9 V and is given by the following
equation:-
VMIN = VSUP - (0.02 x RLOOP)
Where VSUP is supply voltage in Volts
RLOOP is total loop resistance in Ohms
Pulse Power Excitation
Recommended power-on time before output sample is taken
PDCR 1830/1840 - 10 msec
PTX 1830/1840 - 30 msec
For pulse power operation refer to technical note.
Output Signal
PDCR 1830/1840
25 mV for 0.75 mH2O range
50 mV for 1.5 mH2O and 3.5 mH2O ranges
100 mV for ranges 7 mH2O and above
PTX 1830/1840
4 to 20 mA proportional for zero to FS pressure.
Common Mode Voltage - PDCR 1830/1840
Typically +3.5 V to +9 V with respect to the negative supply
Output Impedance - PDCR 1830/1840
2 K⍀ nominal
Performance Specification
Accuracy
Combined effects of Non-linearity, Hysteresis and Repeatability:
Standard: ‫%1.0ע‬ FS BSL maximum
Option D: ‫%60.0ע‬ FS BSL maximum (‫%80.0ע‬ max. for 1 mH2O and below).
Zero Offset and Span Setting
PDCR 1830/1840
Typical: ‫5.1ע‬ mV
Maximum: ‫3ע‬ mV
PTX 1830/1840
Maximum: ‫50.0ע‬ mA
Long-Term Stability
‫%1.0ע‬ typically per annum.
Operating Temperature Range
-20Њ to 60ЊC.
Compensated Temperature Range
-2Њ to 30ЊC.
Temperature Effects
‫%3.0ע‬ FS for 3.5 mH2O range and above
For ranges below 3.5 mH2O multiply x 2.
Shock and Vibration
MIL-STD-810E, method 514.4. Category 10 min. Figure 514.4-16
Product will withstand 20 g peak shock half sine wave 9 mS duration in
all axes, also 2000 g peak shock 0.5 mS duration in all axes.
Insulation
Standard: >100 M⍀ at 500 Vd.c.
Intrinsically Safe version: <5 mA at 500 Va.c.
EMC and Surge Protection
CE Marked. PTX 1830/1840: IEC 61000-6-2: 1999 (10V/m Heavy Industrial)
Intrinsic Safety
PDCR 1830/1840
Certified (BAS02ATEX1250X) for use with IS barrier systems to EEx ia IIC
T4
(80ЊC ambient) for cable lengths up to 29 metres maximum.
PTX 1830/1840
Certified (BAS 01 ATEX 1018X) for use with IS barrier systems to EEx ia IIC
(-40ЊC <= Tamb <= 80ЊC) for cable lengths up to 300 metres maximum.
Physical Specification
Pressure Connection
Standard: Radial holed M14 x 1.5 mm male thread fitted with protective
acetal nose cone.
Option C: Screw on welded male pressure connectors available
G1/8B (60Њ Int Cone)
G1/4B (60Њ Int Cone or Flat End)
1/4” NPT
7/16 UNF to MS33656-4
Electrical Connection
1830: Vented polyurethane cable with integral Kevlar strain relief cord
rated to 54 kg load. Water ingress protection IP68 to 700 mH2O.
1840: Vented Hytrel 6108 cable (hydrocarbon resistant).
Cable Lengths
To be specified as required in 1 metre increments up to 500 metres.
For longer lengths refer to GE Druck.
Documentation
Detailed user instructions are provided with specific calibration data.
Supplied in English, French, German, Italian, Spanish or Portuguese
language - selected on order.
OPTIONS
(A) Lightning Surge Arrestor (PTX 1830/1840 only)
Integral lightning protection assembly certified to European standard
IEC 61000-4-5 (level 4).
(B) Intrinsically Safe Version
(C) Alternative Pressure Connection
In place of the standard acetal nose cone, a screw-on welded male
pressure connection can be supplied. Refer to specifications.
(D) Improved Accuracy
An improved accuracy of ‫%60.0ע‬ FS BSL is available
(‫%80.0ע‬ FS BSL for ranges below 1 mH2O).
ACCESSORIES
A full range of accessories is available to enhance installation, operation
and maintenance of the 1830 series as listed below:
STE Moistureproof Slimline Sink Weight Short Sink Weight
Sensor Termination 17.5 mm Diameter 25.4 mm Diameter
Enclosure (202-034-01) (DA2608-1-01) (DA4608-1-01)
Cable Clamp 360Њ Rotatable Economical Direct
System Calibration Adaptor Calibration Adaptor
(192-373-01) (DA4112-1-01) (DA2537-1-01)
RELATED PRODUCTS
GE Druck manufactures a wide range of pressure transducers and
transmitters, associated digital indicators, barometers, and a complete
range of precision process calibrators and controllers for the field,
workshop and laboratory. A selection of these is shown below:
RTX 1000 rangeable transmitter DPI 610 portable pressure calibrator
PTX 7500 industrial transmitter UPS III Loop calibrator
DPI 280 programmable DPI 515 high speed precision
level digital indicator pressure controller/calibrator
Please refer to GE Druck for further information on related products.
ORDERING INFORMATION
Please state the following:
(1) Model PDCR 1830 (mV) or PTX 1830 (mA) - Polyurethane cable
Model PDCR 1840 (mV) or PTX 1840 (mA) - Hytrel 6108 cable
(2) Pressure range and scale units
(3) Options (if required)
(4) Cable length required
(5) End user instruction manual language
(6) Accessories (order as separate items)
Continuing development sometimes necessitates specification
changes without notice.
Electrical Connections
PDCR 1830 - Polyurethane cable
PDCR 1840 - Hytrel 6108 cable
Red: Supply positive
White: Supply negative
Yellow: Output positive
Blue: Output negative
Screen wire connected to case
(IS version - screen not connected)
Remaining cores not connected
PTX 1830 - Polyurethane cable
PTX 1840 - Hytrel 6108 cable
Red: Supply positive
Blue: Supply negative
Screen wire connected to case
(IS version - screen not connected)
Remaining cores not connected
105 approx
Ø 17.5
M14 x 1.5 exposed thread
with nose cone removed
M14 x 1.5 exposed thread
with nose cone removed
Ø 8 nominal
185 approx (240 with option A - Lightning Surge Arrestor)
Ø 17.5
Ø 8 nominal
P D C R / P T X 1 8 3 0 / 1 8 4 0 S e r i e s
High Performance Level Pressure Sensors
Druck Limited
Fir Tree Lane, Groby, Leicester, LE6 0FH, UK
+44 (0)116 2317100 Fax:+44 (0)116 2317103
E-Mail: sales@druck.com www.druck.com
Agent:
DRAFT - 05/03/04
GE Druckg
Group
INSTALLATION DRAWINGS - Dimensions mm

More Related Content

PDF
Pressure-Control-Brochure
PDF
PDF
Producto 0164-84713
PDF
Vaisala HMT330 Series IndustrialTemperature and Humidity Transmitters
PDF
Cataloge schneider contactor ct-dienhathe.vn
PDF
Functional Safety Frequency to DC Transmitter
PDF
Magnetostrictive Liquid Level Transmitter for Process Measurement and Control
PDF
Flexim Americas - Non-Intrusive Liquid Flow Measurement
Pressure-Control-Brochure
Producto 0164-84713
Vaisala HMT330 Series IndustrialTemperature and Humidity Transmitters
Cataloge schneider contactor ct-dienhathe.vn
Functional Safety Frequency to DC Transmitter
Magnetostrictive Liquid Level Transmitter for Process Measurement and Control
Flexim Americas - Non-Intrusive Liquid Flow Measurement

What's hot (14)

PDF
Continuous Measuring Gas Density Meters
PDF
Jogler magnetic level gauge brochure
PDF
Htr india-products-wire-wound-resistors-silicone-coated-resistors-hia-english...
PDF
Seaward Catalog High Voltage Test Tools
PDF
Ronan Intrinsic Safety Barriers
PDF
Original N-Channel Mosfet TK5A50D 5A50D 500V 5A TO-220F New Toshiba
PDF
Magnetostrictive Liquid Level Transmitters
PDF
Original N Channel Mosfet T5A50D K5A50D 5A50D TO-220 5A 500V New Toshiba(Repl...
PDF
Av02 3563 en-ds_acpl-c87x_04mar2013-2
PDF
Omnik inverter-5k-6k-7k-8k-tl
PDF
Stator Resistance Temperature Detector (RTD) - Catalog
PDF
PDF
AC Hysteresis Graph Plotter by ACMAS Technologies Pvt Ltd.
Continuous Measuring Gas Density Meters
Jogler magnetic level gauge brochure
Htr india-products-wire-wound-resistors-silicone-coated-resistors-hia-english...
Seaward Catalog High Voltage Test Tools
Ronan Intrinsic Safety Barriers
Original N-Channel Mosfet TK5A50D 5A50D 500V 5A TO-220F New Toshiba
Magnetostrictive Liquid Level Transmitters
Original N Channel Mosfet T5A50D K5A50D 5A50D TO-220 5A 500V New Toshiba(Repl...
Av02 3563 en-ds_acpl-c87x_04mar2013-2
Omnik inverter-5k-6k-7k-8k-tl
Stator Resistance Temperature Detector (RTD) - Catalog
AC Hysteresis Graph Plotter by ACMAS Technologies Pvt Ltd.
Ad

Viewers also liked (19)

PPTX
Stock market game
PPTX
CRS Introduction
PPTX
Deber de jonathan flores
ODP
認識Chakra
PPT
2012.presentation
PPTX
Sachin patel
PPTX
Pagina857
PPT
Bloomspres
PDF
Photovoltaic guide-en
PDF
High Impact Prospecting V15
PPT
Main
PPTX
CRS Introduction TEEC
PDF
Networking Israeli Day 2013 - Hecatonchire: Transparent Memory Aggregation
PDF
VHPC'12: Pre-Copy and Post-Copy VM Live Migration for Memory Intensive Applic...
PDF
projects
PPT
Presentatie Stern Groep
PPTX
Science Fair Experiment -Linda Choi 9th-
PDF
SAP Virtualization Week 2012 - The Lego Cloud
PDF
Valgrind
Stock market game
CRS Introduction
Deber de jonathan flores
認識Chakra
2012.presentation
Sachin patel
Pagina857
Bloomspres
Photovoltaic guide-en
High Impact Prospecting V15
Main
CRS Introduction TEEC
Networking Israeli Day 2013 - Hecatonchire: Transparent Memory Aggregation
VHPC'12: Pre-Copy and Post-Copy VM Live Migration for Memory Intensive Applic...
projects
Presentatie Stern Groep
Science Fair Experiment -Linda Choi 9th-
SAP Virtualization Week 2012 - The Lego Cloud
Valgrind
Ad

Similar to Depth and level_sensor_pdcr1830 (20)

PDF
ESI Technology Pressure Transducers & Transmitters
PDF
Hydrostatic Liquid Level Transmitters for Industrial Process Measurement
PDF
3100 3200-cat
PDF
Drager Polytron 8000 Fixed Gas Detector - Spec Sheet
PDF
Dräger Polytron 8700 Fixed Gas Detector - Spec Sheet
PDF
Differential Pressure Switch/ Gages
PDF
MP17 All Ss Electric Contact Pressure Gauge - High Version Case
PDF
Draft Guage Indicator for boiler draft measurement
PDF
Drager Polytron 8200 Fixed Gas Detector - Spec Sheet
PDF
CrystalCalHP - Calibration Lab in a Box
PDF
Datasheet Fluke 718 Ex. Hubungi PT. Siwali Swantika 021-45850618
PDF
Pune techtrol level measurement
PDF
Drager Polytron 8700 Fixed Gas Detector - Spec Sheet
PDF
Medidor digital de presion 680 UserManual.pdf
PDF
Drager Polytron 5200 Fixed Gas Detector - Spec Sheet
PDF
1442 td001 -en-p
PDF
Yokogawa EJX110A Differential Pressure Tranismitter
PDF
Ashcroft Inc - Product Overview
ESI Technology Pressure Transducers & Transmitters
Hydrostatic Liquid Level Transmitters for Industrial Process Measurement
3100 3200-cat
Drager Polytron 8000 Fixed Gas Detector - Spec Sheet
Dräger Polytron 8700 Fixed Gas Detector - Spec Sheet
Differential Pressure Switch/ Gages
MP17 All Ss Electric Contact Pressure Gauge - High Version Case
Draft Guage Indicator for boiler draft measurement
Drager Polytron 8200 Fixed Gas Detector - Spec Sheet
CrystalCalHP - Calibration Lab in a Box
Datasheet Fluke 718 Ex. Hubungi PT. Siwali Swantika 021-45850618
Pune techtrol level measurement
Drager Polytron 8700 Fixed Gas Detector - Spec Sheet
Medidor digital de presion 680 UserManual.pdf
Drager Polytron 5200 Fixed Gas Detector - Spec Sheet
1442 td001 -en-p
Yokogawa EJX110A Differential Pressure Tranismitter
Ashcroft Inc - Product Overview

Recently uploaded (20)

PPTX
Current and future trends in Computer Vision.pptx
PDF
A SYSTEMATIC REVIEW OF APPLICATIONS IN FRAUD DETECTION
PDF
distributed database system" (DDBS) is often used to refer to both the distri...
PPTX
Software Engineering and software moduleing
PDF
BIO-INSPIRED ARCHITECTURE FOR PARSIMONIOUS CONVERSATIONAL INTELLIGENCE : THE ...
PPTX
Information Storage and Retrieval Techniques Unit III
PDF
22EC502-MICROCONTROLLER AND INTERFACING-8051 MICROCONTROLLER.pdf
PDF
Categorization of Factors Affecting Classification Algorithms Selection
PDF
III.4.1.2_The_Space_Environment.p pdffdf
PDF
Visual Aids for Exploratory Data Analysis.pdf
PDF
Exploratory_Data_Analysis_Fundamentals.pdf
PPTX
Artificial Intelligence
PPT
INTRODUCTION -Data Warehousing and Mining-M.Tech- VTU.ppt
PDF
737-MAX_SRG.pdf student reference guides
PDF
null (2) bgfbg bfgb bfgb fbfg bfbgf b.pdf
PDF
Human-AI Collaboration: Balancing Agentic AI and Autonomy in Hybrid Systems
PDF
Automation-in-Manufacturing-Chapter-Introduction.pdf
PDF
R24 SURVEYING LAB MANUAL for civil enggi
PPT
Occupational Health and Safety Management System
PDF
Accra-Kumasi Expressway - Prefeasibility Report Volume 1 of 7.11.2018.pdf
Current and future trends in Computer Vision.pptx
A SYSTEMATIC REVIEW OF APPLICATIONS IN FRAUD DETECTION
distributed database system" (DDBS) is often used to refer to both the distri...
Software Engineering and software moduleing
BIO-INSPIRED ARCHITECTURE FOR PARSIMONIOUS CONVERSATIONAL INTELLIGENCE : THE ...
Information Storage and Retrieval Techniques Unit III
22EC502-MICROCONTROLLER AND INTERFACING-8051 MICROCONTROLLER.pdf
Categorization of Factors Affecting Classification Algorithms Selection
III.4.1.2_The_Space_Environment.p pdffdf
Visual Aids for Exploratory Data Analysis.pdf
Exploratory_Data_Analysis_Fundamentals.pdf
Artificial Intelligence
INTRODUCTION -Data Warehousing and Mining-M.Tech- VTU.ppt
737-MAX_SRG.pdf student reference guides
null (2) bgfbg bfgb bfgb fbfg bfbgf b.pdf
Human-AI Collaboration: Balancing Agentic AI and Autonomy in Hybrid Systems
Automation-in-Manufacturing-Chapter-Introduction.pdf
R24 SURVEYING LAB MANUAL for civil enggi
Occupational Health and Safety Management System
Accra-Kumasi Expressway - Prefeasibility Report Volume 1 of 7.11.2018.pdf

Depth and level_sensor_pdcr1830

  • 1. GE Druck g 1 8 3 0 / 1 8 4 0 S e r i e s High Performance Level Pressure Sensors Ⅲ Ranges from 0.75 mH20 to 600 mH20 Ⅲ Accuracy ‫%60.0ע‬ Ⅲ Fully welded 17.5 mm titanium construction Ⅲ Integral lightning surge arrestor Ⅲ Polyurethane and hydrocarbon resistant cables Ⅲ Full range of installation accessories
  • 2. ADVANCED PRESSURE SENSORS FOR A WORLD OF LEVEL MEASUREMENTS Established in 1972, GE Druck specialises in the manufacture of high performance pressure measurement and related control equipment. The PDCR 1830/1840 transducer (mV output) and PTX 1830/1840 transmitter (4-20 mA output) are the latest generation of fully submersible high performance sensors for measurement of hydrostatic liquid levels. The PDCR/PTX 1830/1840 series incorporates many enhanced features gained from Druck’s experience in supplying thousands of sensors for small and large scale installations worldwide. Example applications include: ⅷ Potable Water From ground water borehole to surface water level measurements in rivers, canals and reservoirs. ⅷ Waste Water and Remediation Monitoring of secondary and outflow sewage levels within certified hazardous areas and contaminated ground water levels in land fill sites. ⅷ Tank Level From land based liquid storage vessels to on-board ship ballast tank monitoring within safe and certified hazardous areas, using potable water approved (1830) cable and hydrocarbon resistant (1840) cable. ⅷ Sea Water Marine environmental applications including tide gauging, coastal/flood protection and wave profiling amongst others. Reliability and Data Quality The combination of a high technology sensor, together with advanced signal conditioning and packaging techniques, provides an ideal long- term solution for reliable, accurate and economical level measurements. The GE Druck micromachined silicon element is sealed within an all- titanium pressure module assembly, fully isolated from the pressure media. This is contained in a slimline, welded titanium body, terminated in an injection moulded cable assembly. The cable features a kevlar strain cord and is IP68 rated for indefinite immersion in 700 mH2O, with selection of cable material to meet the application. Lightning Surge Protection An optional integral lightning surge arrestor is available, qualified to the highest European standard IEC 61000-4-5 (level 4). This protects the sensor from raised earth potentials caused by lightning strikes, which often occur in surface water applications. Ease of Use A simple datum marked cable system is provided for ease of installation. Incremental 1 m datum points are clearly marked for quick and accurate alignment below ground level. In addition, a full range of related accessories simplifies installation, operation and maintenance. ⅷ Quick-release cable clamp assembly ⅷ Slimline and short profile sink weights ⅷ Moistureproof Sensor Termination Enclosure ⅷ In-situ pressure test/calibration adaptors P D C R / P T X 1 8 3 0 / 1 8 4 0 S e r i e s High Performance Level Pressure Sensors
  • 3. STANDARD SPECIFICATIONS Pressure Measurement Operating Pressure Ranges PDCR 1830/1840 (mV) 0.75, 1.5 mH2O gauge, 3.5, 7, 10, 15, 20, 35, 50, 70, 100, 150, 200, 350, 600 mH2O gauge and absolute PTX 1830/1840 (mA) Any zero based full scale (FS) from 0.75 to 600 mH2O gauge. 3.5 to 600 mH2O absolute. Elevated zero, compound and reversed output ranges available. Refer to GE Druck for further information. Other units may be specified e.g. ftH2O, InH2O, bar, mbar, psi, kpa, kg/cm 2 Overpressure The operating FS pressure range may be exceeded by the following multiples with negligible effect on calibration: 8 x for ranges up to 1.5 mH2O 6 x for ranges above 1.5 mH2O to 3.5 mH2O 4 x for ranges above 3.5 mH2O (1400 mH2O max.) Pressure Containment 10 x for ranges up to 3.5 mH2O gauge 6 x for ranges above 3.5 mH2O gauge (1400 mH2O max.) 200 bar for absolute ranges. Media Compatibility Fluids compatible with titanium (body), acetal (nose cone) and polyurethane or Hytrel 6108 (cable assembly). Excitation Voltage PDCR 1830/1840 (mV) 10 V at 5 mA nominal Output is fully ratiometric to supply within 2.5 V to 12 V limits. PTX 1830/1840 (mA) 9 to 30 V 9 to 28 V for Intrinsically Safe version. The minimum supply voltage (VMIN) which must appear across the pressure transmitter terminals is 9 V and is given by the following equation:- VMIN = VSUP - (0.02 x RLOOP) Where VSUP is supply voltage in Volts RLOOP is total loop resistance in Ohms Pulse Power Excitation Recommended power-on time before output sample is taken PDCR 1830/1840 - 10 msec PTX 1830/1840 - 30 msec For pulse power operation refer to technical note. Output Signal PDCR 1830/1840 25 mV for 0.75 mH2O range 50 mV for 1.5 mH2O and 3.5 mH2O ranges 100 mV for ranges 7 mH2O and above PTX 1830/1840 4 to 20 mA proportional for zero to FS pressure. Common Mode Voltage - PDCR 1830/1840 Typically +3.5 V to +9 V with respect to the negative supply Output Impedance - PDCR 1830/1840 2 K⍀ nominal Performance Specification Accuracy Combined effects of Non-linearity, Hysteresis and Repeatability: Standard: ‫%1.0ע‬ FS BSL maximum Option D: ‫%60.0ע‬ FS BSL maximum (‫%80.0ע‬ max. for 1 mH2O and below). Zero Offset and Span Setting PDCR 1830/1840 Typical: ‫5.1ע‬ mV Maximum: ‫3ע‬ mV PTX 1830/1840 Maximum: ‫50.0ע‬ mA Long-Term Stability ‫%1.0ע‬ typically per annum. Operating Temperature Range -20Њ to 60ЊC. Compensated Temperature Range -2Њ to 30ЊC. Temperature Effects ‫%3.0ע‬ FS for 3.5 mH2O range and above For ranges below 3.5 mH2O multiply x 2. Shock and Vibration MIL-STD-810E, method 514.4. Category 10 min. Figure 514.4-16 Product will withstand 20 g peak shock half sine wave 9 mS duration in all axes, also 2000 g peak shock 0.5 mS duration in all axes. Insulation Standard: >100 M⍀ at 500 Vd.c. Intrinsically Safe version: <5 mA at 500 Va.c. EMC and Surge Protection CE Marked. PTX 1830/1840: IEC 61000-6-2: 1999 (10V/m Heavy Industrial) Intrinsic Safety PDCR 1830/1840 Certified (BAS02ATEX1250X) for use with IS barrier systems to EEx ia IIC T4 (80ЊC ambient) for cable lengths up to 29 metres maximum. PTX 1830/1840 Certified (BAS 01 ATEX 1018X) for use with IS barrier systems to EEx ia IIC (-40ЊC <= Tamb <= 80ЊC) for cable lengths up to 300 metres maximum. Physical Specification Pressure Connection Standard: Radial holed M14 x 1.5 mm male thread fitted with protective acetal nose cone. Option C: Screw on welded male pressure connectors available G1/8B (60Њ Int Cone) G1/4B (60Њ Int Cone or Flat End) 1/4” NPT 7/16 UNF to MS33656-4 Electrical Connection 1830: Vented polyurethane cable with integral Kevlar strain relief cord rated to 54 kg load. Water ingress protection IP68 to 700 mH2O. 1840: Vented Hytrel 6108 cable (hydrocarbon resistant). Cable Lengths To be specified as required in 1 metre increments up to 500 metres. For longer lengths refer to GE Druck. Documentation Detailed user instructions are provided with specific calibration data. Supplied in English, French, German, Italian, Spanish or Portuguese language - selected on order.
  • 4. OPTIONS (A) Lightning Surge Arrestor (PTX 1830/1840 only) Integral lightning protection assembly certified to European standard IEC 61000-4-5 (level 4). (B) Intrinsically Safe Version (C) Alternative Pressure Connection In place of the standard acetal nose cone, a screw-on welded male pressure connection can be supplied. Refer to specifications. (D) Improved Accuracy An improved accuracy of ‫%60.0ע‬ FS BSL is available (‫%80.0ע‬ FS BSL for ranges below 1 mH2O). ACCESSORIES A full range of accessories is available to enhance installation, operation and maintenance of the 1830 series as listed below: STE Moistureproof Slimline Sink Weight Short Sink Weight Sensor Termination 17.5 mm Diameter 25.4 mm Diameter Enclosure (202-034-01) (DA2608-1-01) (DA4608-1-01) Cable Clamp 360Њ Rotatable Economical Direct System Calibration Adaptor Calibration Adaptor (192-373-01) (DA4112-1-01) (DA2537-1-01) RELATED PRODUCTS GE Druck manufactures a wide range of pressure transducers and transmitters, associated digital indicators, barometers, and a complete range of precision process calibrators and controllers for the field, workshop and laboratory. A selection of these is shown below: RTX 1000 rangeable transmitter DPI 610 portable pressure calibrator PTX 7500 industrial transmitter UPS III Loop calibrator DPI 280 programmable DPI 515 high speed precision level digital indicator pressure controller/calibrator Please refer to GE Druck for further information on related products. ORDERING INFORMATION Please state the following: (1) Model PDCR 1830 (mV) or PTX 1830 (mA) - Polyurethane cable Model PDCR 1840 (mV) or PTX 1840 (mA) - Hytrel 6108 cable (2) Pressure range and scale units (3) Options (if required) (4) Cable length required (5) End user instruction manual language (6) Accessories (order as separate items) Continuing development sometimes necessitates specification changes without notice. Electrical Connections PDCR 1830 - Polyurethane cable PDCR 1840 - Hytrel 6108 cable Red: Supply positive White: Supply negative Yellow: Output positive Blue: Output negative Screen wire connected to case (IS version - screen not connected) Remaining cores not connected PTX 1830 - Polyurethane cable PTX 1840 - Hytrel 6108 cable Red: Supply positive Blue: Supply negative Screen wire connected to case (IS version - screen not connected) Remaining cores not connected 105 approx Ø 17.5 M14 x 1.5 exposed thread with nose cone removed M14 x 1.5 exposed thread with nose cone removed Ø 8 nominal 185 approx (240 with option A - Lightning Surge Arrestor) Ø 17.5 Ø 8 nominal P D C R / P T X 1 8 3 0 / 1 8 4 0 S e r i e s High Performance Level Pressure Sensors Druck Limited Fir Tree Lane, Groby, Leicester, LE6 0FH, UK +44 (0)116 2317100 Fax:+44 (0)116 2317103 E-Mail: sales@druck.com www.druck.com Agent: DRAFT - 05/03/04 GE Druckg Group INSTALLATION DRAWINGS - Dimensions mm