Liebert RG
Green power solution for
Regenerative load
Application
Salient features
Four Quadrant IGBT based PWM Rectifier :
Suitable for Regenerative load application
Input THDi < 3%
Clean grid
Input PF > 0.99
Start-of-art-of Digital Control
Full galvanic isolation as default inbuilt
Energy saving during regenerative transients
Rating available(kVA): 40, 60, 80, 120, 160, 200, 250
Liebert RG
General Overview
Liebert RG
Green Power Solution for
Regenerative Load Application
Liebert RG
Dynamic
Performance
Connectivity Working
principal
Energy
Saving
Excellent input output
Performances
Liebert RG
Three-phase input:
• Input PF ≥ 0.99
• THDi ≤ 3%
• Voltage: 332 – 477 V
• Frequency: 50/60 Hz
Three-phase output:
• Output PF: 0.8
• Voltage: 380V - 400V - 415V
(selectable)
• Frequency: 50/60 Hz (selectable)
UPS INPUT UPS OUTPUT
F
V V
F
Power Rating
Liebert RG
1335 mm
600 mm
40 kVA W x D x H
600 mm x 900 mm x 1335 mm
• Footprint : 0.54Sq m
• Weight (kg) : 480
• Txr integrated in
the same foot print
Power Rating
Liebert RG
60 kVA
80 kVA
120 kVA
160 kVA
200 kVA
250 kVA
1750 mm
1000 mm
• Footprint : 0.9Sq m
• Weight (kg) : 875
• Txr integrated in
the same foot print
Power Rating
Liebert RG
60 kVA
80 kVA
120 kVA
160 kVA
200 kVA
250 kVA
1750 mm
1000 mm
• Footprint : 0.9 Sq m
• Weight (kg) : 875
• Txr integrated in
the same foot print
Power Rating
Liebert RG
60 kVA
80 kVA
120 kVA
160 kVA
200 kVA
250 kVA
1850 mm
1200 mm
• Footprint : 1.08 Sq m
• Weight (kg) : 950
• Txr integrated in
the same foot print
Power Rating
Liebert RG
60 kVA
80 kVA
120 kVA
160 kVA
200 kVA
250 kVA
2000 mm
1400 mm
• Footprint : 1.4 Sq m
• Weight (kg) : 1300
• Txr integrated in
the same foot print
Power Rating
Liebert RG
60 kVA
80 kVA
120 kVA
160 kVA
200 kVA
250 kVA
2000 mm
1400 mm
• Footprint : 1.4 Sq m
• Weight (kg) : 1300
• Txr integrated in
the same foot print
Power Rating
Liebert RG
60 kVA
80 kVA
120 kVA
160 kVA
200 kVA
250 kVA
2000 mm
Rect : 1000
Inv. : 1400
• Footprint : 1.0 Sq m
1.4 Sq.m
• Weight (kg) : 800 + 1050
• Txr integrated in
the same foot print
2 cabinets
Power Rating
Liebert RG
 Full compatibility with all types of loads with PF up to 0.6 without de-rating.
Fully compliant with leading power factor loads.
 UPS do not require de-rating for leading power factors and can be connected
to any load within the nominal kVA and kW rating of the UPS regardless of
power factor.
Microprocessor based
Digital Control
Liebert RG
 Lesser cards, thus increasing the reliability
 A quick and flexible processing of data
 This allows better control of the UPS electronics
 Faster and easier serviceability
 Advanced LCD Display
Monitors the input, Output, Battery & Bypass parameters
 Stores important events with date & time
 Better Output quality and correction rate
Perfect Output
Waveform
Liebert RG
Full Galvanic
isolation
Liebert RG
 Galvanic isolation at output power
 Avoid serious problem due to neutral conductor open at load side
 Avoid permanent damage to the load due to lightening
 Stops ground loop currents reaching the load due to isolated and
dedicated earthing
Green Power Solution for
Regenerative Load Application
Liebert RG
Dynamic
Performance
Connectivity Working
Principal
Energy
Saving
What is
Regenerative
Power?
Fig a) Normal operation of 3 Phase motor with drive
Fig b) Breaking mechanism slows/stops the motor, which generates regenerative power &
returned to the input side i.e. to the power supply. In case of UPS as power
supply, it shall be capable to feed back the regenerative power to the mains.
Liebert RG
Working Principal
Liebert RG
Re-
generative
Load
Bypass
Input
Battery
IGBT
Rectifier
IGBT
Inverter
Isolation
Transformer
STSW
STSW
Mains
Input
Normal
mode
In Normal mode, the rectifier derives power from the commercial AC source and converts it into DC power for the
inverter and the battery charger. The battery charger keeps the battery in a fully charged and optimum operational
condition. The inverter converts the DC power into clean and regulated AC power which is supplied to the critical load
(conditioned line). The static switch monitors and ensures that the inverter tracks the bypass supply frequency. This
ensures that any automatic transfer to the bypass supply (due to an overload etc.) is frequency synchronised and does
not cause interruption to the critical load.
Working Principal
Liebert RG
Re-
generative
Load
Bypass
Input
Battery
IGBT
Rectifier
IGBT
Inverter
Isolation
Transformer
STSW
STSW
Mains
Input
Dynamic
breaking
mode
When Braking mechanism slows/stops the motor, which generates regenerative power & returned to
the input side i.e. to the power supply. In such condition, Liebert RG fed back the regenerative power to the
mains via Inverter & Rectifier without causing interruption to the critical load & thus there will be
considerable energy savings during regeneration transients.
Regenerative
Power
Regenerative Power
fed to Mains
Green Power Solution for
Regenerative Load Application
Liebert RG
Dynamic
Performance
Connectivity
Energy
Saving
Working
Principle
Energy saving during
regenerative transients
Liebert RG
When using a Liebert RG
UPS (Regenerative
compatible power unit), the
regenerative energy of a
drive can be used by other
loads, which saves energy.
Liebert
RG
Energy saving during
regenerative transients
Regenerative
Power
Running
Power
Energy
Saving
Note : This is an example. Depend upon applications, trend may vary.
Liebert RG
Green Power Solution for
Regenerative Load Application
Liebert RG
Dynamic
Performance
Connectivity
Working
principal
Flexibility
Connectivity options
 UPS Monitoring Software (RS232 / Ethernet)
 Remote Monitoring Panel (i-Remote Ethernet based)
 SNMP
 MODBUS
Liebert RG
UPS Monitoring
Software
Liebert RG
 Mailing of the events via SMTP Protocol
 Initiate graceful automation shutdown of the operating system
and servers.
 Auto Saving feature at the time of Shutdown for windows XP,
Windows 2000 server and above.
 Sequential shutdown of different servers at different timings
 Multiple UPS Monitoring via serial port or through Ethernet
 Notifies events through SMS messages
 Supports to Window 98, Windows 2000 & Windows XP
operating Systems
 Log events to analyse performance of UPS & allied Hardware
UPS Monitoring
Software
Liebert RG
Remote Monitoring Panel –
i-Remote
Liebert RG
 Selection & Monitoring of up to 4 UPS
 Microprocessor based remote panel
 Ethernet Connectivity
 Auto detection software to set network
parameters & UPS parameters
 Keypad for user interface
 Inbuilt Battery Backup
 LCD Display & LED Indications
 Compact Size : 195 (W) x 65(D) x 245 (H) in mm
Features
Remote Monitoring Panel –
i-Remote
Liebert RG
LED Indications
 UPS Selection
 Inverter ON
 Mains fails
 Rectifier Trip
 Load on Battery
 Battery Low
 Overload
 Over Temperature
 Inverter Trip
 Load on Bypass
 Alarm (Fault)
SNMP (STOE card)
Liebert RG
 A small microprocessor based multifunction hardware
 It facilitates monitoring of UPS through different systems supporting
various networking protocols as like SNMP, TCP/IP, HTTP.
 It has different ports for connectivity with the network.
 One RJ45 10 Mbps Ethernet port
 One RS232 output port
 Operates as a server for different monitoring protocols
 Setting of network configuration parameters through Detection Software
 Trap generation through SNMP on different faults
Features
SNMP (STOE card)
Liebert RG
Liebert RG UPS for Regenerative Load Applications

More Related Content

PPTX
Obstacle Avoidance ROBOT using ARDUINO
PPTX
Designing Artificial Intelligence
PDF
Audio amplifier
PPT
waveshaping ckts
PPTX
Third Eye for blind.pptx
PPTX
Simple Automatic Water Level Controller by using ic 555 timer.
PDF
Calcul section-cable-eclairagepublic
PPTX
Filter circuits
Obstacle Avoidance ROBOT using ARDUINO
Designing Artificial Intelligence
Audio amplifier
waveshaping ckts
Third Eye for blind.pptx
Simple Automatic Water Level Controller by using ic 555 timer.
Calcul section-cable-eclairagepublic
Filter circuits

What's hot (20)

PPTX
Iot based health monitoring system
PPTX
Arduino and its hw architecture
PPTX
A project on wheelchair motion control using eye gaze and blinks
PPTX
Sensor Based Blind Stick
PPT
Protections des transformateurs et lignes.ppt
PPTX
low cost fire alarm circuit
PPTX
IGBT and their Characteristics
PDF
2743557 dossier-ppe-robot-suiveur-de-ligne
PPTX
Deep Learning A-Z™: Convolutional Neural Networks (CNN) - Step 3: Flattening
PPTX
Smart home Environment using iot
PPTX
Clampers
PDF
Arduino Basics
PPTX
AI Computer vision
PDF
Op amp comparator
PDF
PDF
Schmitt trigger basics
PPTX
Embedded Systems - Training ppt
PDF
PLC Based Automatic car wash system By Irfan Anjum
PPTX
part3.pptx
PPTX
Smart walking Stick for blinds
Iot based health monitoring system
Arduino and its hw architecture
A project on wheelchair motion control using eye gaze and blinks
Sensor Based Blind Stick
Protections des transformateurs et lignes.ppt
low cost fire alarm circuit
IGBT and their Characteristics
2743557 dossier-ppe-robot-suiveur-de-ligne
Deep Learning A-Z™: Convolutional Neural Networks (CNN) - Step 3: Flattening
Smart home Environment using iot
Clampers
Arduino Basics
AI Computer vision
Op amp comparator
Schmitt trigger basics
Embedded Systems - Training ppt
PLC Based Automatic car wash system By Irfan Anjum
part3.pptx
Smart walking Stick for blinds
Ad

Similar to Liebert RG UPS for Regenerative Load Applications (20)

PDF
Eaton ats automatic transfer switch ats pwr
PDF
Eaton ATS Automatic Transfer Switch ATS-PWR
PDF
Ls catalog thiet bi tu dong i s5_e_1105_dienhathe.vn
PDF
Modular UPS 40 - 1.5 MVA.pdf
PDF
IGBT Based Static Voltage Regulator
PDF
RS Power Systems Profile
PDF
Advanced motions control 16a20ac
PDF
Catalog biến tần Frenic Lift - Fuji Electric mới nhất 2019
PDF
Advanced motion controls azbe25a20
PDF
Advanced motion controls b40a40
PDF
Fuji tu dong hoa catalog inverter-frenic-lift-fuji-dienhathe.org
PPTX
Speed control of motor
PDF
Advanced motion controls azbe10a20
PPT
9900 Presentation
PDF
Mitsubishi 9900 presentation 7 1-08
PDF
Advanced motion controls azbe40a8
PDF
Kg catalogue dc electronic load distributed by Nihon Denkei
PDF
KG Electronic load DC power supply Ripple and Noise meter
PDF
Kg catalogue dc electronic load
PDF
Advanced motion controls azbe60a8
Eaton ats automatic transfer switch ats pwr
Eaton ATS Automatic Transfer Switch ATS-PWR
Ls catalog thiet bi tu dong i s5_e_1105_dienhathe.vn
Modular UPS 40 - 1.5 MVA.pdf
IGBT Based Static Voltage Regulator
RS Power Systems Profile
Advanced motions control 16a20ac
Catalog biến tần Frenic Lift - Fuji Electric mới nhất 2019
Advanced motion controls azbe25a20
Advanced motion controls b40a40
Fuji tu dong hoa catalog inverter-frenic-lift-fuji-dienhathe.org
Speed control of motor
Advanced motion controls azbe10a20
9900 Presentation
Mitsubishi 9900 presentation 7 1-08
Advanced motion controls azbe40a8
Kg catalogue dc electronic load distributed by Nihon Denkei
KG Electronic load DC power supply Ripple and Noise meter
Kg catalogue dc electronic load
Advanced motion controls azbe60a8
Ad

Recently uploaded (20)

PDF
Produktkatalog für HOBO Datenlogger, Wetterstationen, Sensoren, Software und ...
PDF
OpenACC and Open Hackathons Monthly Highlights July 2025
PPTX
2018-HIPAA-Renewal-Training for executives
PDF
A proposed approach for plagiarism detection in Myanmar Unicode text
PDF
Developing a website for English-speaking practice to English as a foreign la...
PPTX
Final SEM Unit 1 for mit wpu at pune .pptx
PPTX
Microsoft Excel 365/2024 Beginner's training
PPT
Module 1.ppt Iot fundamentals and Architecture
PPTX
GROUP4NURSINGINFORMATICSREPORT-2 PRESENTATION
PPTX
Modernising the Digital Integration Hub
PPT
Geologic Time for studying geology for geologist
PDF
Comparative analysis of machine learning models for fake news detection in so...
PPTX
Chapter 5: Probability Theory and Statistics
DOCX
search engine optimization ppt fir known well about this
PDF
Architecture types and enterprise applications.pdf
PDF
How IoT Sensor Integration in 2025 is Transforming Industries Worldwide
PDF
Convolutional neural network based encoder-decoder for efficient real-time ob...
PPTX
Benefits of Physical activity for teenagers.pptx
PDF
STKI Israel Market Study 2025 version august
PDF
The influence of sentiment analysis in enhancing early warning system model f...
Produktkatalog für HOBO Datenlogger, Wetterstationen, Sensoren, Software und ...
OpenACC and Open Hackathons Monthly Highlights July 2025
2018-HIPAA-Renewal-Training for executives
A proposed approach for plagiarism detection in Myanmar Unicode text
Developing a website for English-speaking practice to English as a foreign la...
Final SEM Unit 1 for mit wpu at pune .pptx
Microsoft Excel 365/2024 Beginner's training
Module 1.ppt Iot fundamentals and Architecture
GROUP4NURSINGINFORMATICSREPORT-2 PRESENTATION
Modernising the Digital Integration Hub
Geologic Time for studying geology for geologist
Comparative analysis of machine learning models for fake news detection in so...
Chapter 5: Probability Theory and Statistics
search engine optimization ppt fir known well about this
Architecture types and enterprise applications.pdf
How IoT Sensor Integration in 2025 is Transforming Industries Worldwide
Convolutional neural network based encoder-decoder for efficient real-time ob...
Benefits of Physical activity for teenagers.pptx
STKI Israel Market Study 2025 version august
The influence of sentiment analysis in enhancing early warning system model f...

Liebert RG UPS for Regenerative Load Applications

  • 1. Liebert RG Green power solution for Regenerative load Application
  • 2. Salient features Four Quadrant IGBT based PWM Rectifier : Suitable for Regenerative load application Input THDi < 3% Clean grid Input PF > 0.99 Start-of-art-of Digital Control Full galvanic isolation as default inbuilt Energy saving during regenerative transients Rating available(kVA): 40, 60, 80, 120, 160, 200, 250 Liebert RG
  • 4. Green Power Solution for Regenerative Load Application Liebert RG Dynamic Performance Connectivity Working principal Energy Saving
  • 5. Excellent input output Performances Liebert RG Three-phase input: • Input PF ≥ 0.99 • THDi ≤ 3% • Voltage: 332 – 477 V • Frequency: 50/60 Hz Three-phase output: • Output PF: 0.8 • Voltage: 380V - 400V - 415V (selectable) • Frequency: 50/60 Hz (selectable) UPS INPUT UPS OUTPUT F V V F
  • 6. Power Rating Liebert RG 1335 mm 600 mm 40 kVA W x D x H 600 mm x 900 mm x 1335 mm • Footprint : 0.54Sq m • Weight (kg) : 480 • Txr integrated in the same foot print
  • 7. Power Rating Liebert RG 60 kVA 80 kVA 120 kVA 160 kVA 200 kVA 250 kVA 1750 mm 1000 mm • Footprint : 0.9Sq m • Weight (kg) : 875 • Txr integrated in the same foot print
  • 8. Power Rating Liebert RG 60 kVA 80 kVA 120 kVA 160 kVA 200 kVA 250 kVA 1750 mm 1000 mm • Footprint : 0.9 Sq m • Weight (kg) : 875 • Txr integrated in the same foot print
  • 9. Power Rating Liebert RG 60 kVA 80 kVA 120 kVA 160 kVA 200 kVA 250 kVA 1850 mm 1200 mm • Footprint : 1.08 Sq m • Weight (kg) : 950 • Txr integrated in the same foot print
  • 10. Power Rating Liebert RG 60 kVA 80 kVA 120 kVA 160 kVA 200 kVA 250 kVA 2000 mm 1400 mm • Footprint : 1.4 Sq m • Weight (kg) : 1300 • Txr integrated in the same foot print
  • 11. Power Rating Liebert RG 60 kVA 80 kVA 120 kVA 160 kVA 200 kVA 250 kVA 2000 mm 1400 mm • Footprint : 1.4 Sq m • Weight (kg) : 1300 • Txr integrated in the same foot print
  • 12. Power Rating Liebert RG 60 kVA 80 kVA 120 kVA 160 kVA 200 kVA 250 kVA 2000 mm Rect : 1000 Inv. : 1400 • Footprint : 1.0 Sq m 1.4 Sq.m • Weight (kg) : 800 + 1050 • Txr integrated in the same foot print 2 cabinets
  • 13. Power Rating Liebert RG  Full compatibility with all types of loads with PF up to 0.6 without de-rating. Fully compliant with leading power factor loads.  UPS do not require de-rating for leading power factors and can be connected to any load within the nominal kVA and kW rating of the UPS regardless of power factor.
  • 14. Microprocessor based Digital Control Liebert RG  Lesser cards, thus increasing the reliability  A quick and flexible processing of data  This allows better control of the UPS electronics  Faster and easier serviceability  Advanced LCD Display Monitors the input, Output, Battery & Bypass parameters  Stores important events with date & time  Better Output quality and correction rate
  • 16. Full Galvanic isolation Liebert RG  Galvanic isolation at output power  Avoid serious problem due to neutral conductor open at load side  Avoid permanent damage to the load due to lightening  Stops ground loop currents reaching the load due to isolated and dedicated earthing
  • 17. Green Power Solution for Regenerative Load Application Liebert RG Dynamic Performance Connectivity Working Principal Energy Saving
  • 18. What is Regenerative Power? Fig a) Normal operation of 3 Phase motor with drive Fig b) Breaking mechanism slows/stops the motor, which generates regenerative power & returned to the input side i.e. to the power supply. In case of UPS as power supply, it shall be capable to feed back the regenerative power to the mains. Liebert RG
  • 19. Working Principal Liebert RG Re- generative Load Bypass Input Battery IGBT Rectifier IGBT Inverter Isolation Transformer STSW STSW Mains Input Normal mode In Normal mode, the rectifier derives power from the commercial AC source and converts it into DC power for the inverter and the battery charger. The battery charger keeps the battery in a fully charged and optimum operational condition. The inverter converts the DC power into clean and regulated AC power which is supplied to the critical load (conditioned line). The static switch monitors and ensures that the inverter tracks the bypass supply frequency. This ensures that any automatic transfer to the bypass supply (due to an overload etc.) is frequency synchronised and does not cause interruption to the critical load.
  • 20. Working Principal Liebert RG Re- generative Load Bypass Input Battery IGBT Rectifier IGBT Inverter Isolation Transformer STSW STSW Mains Input Dynamic breaking mode When Braking mechanism slows/stops the motor, which generates regenerative power & returned to the input side i.e. to the power supply. In such condition, Liebert RG fed back the regenerative power to the mains via Inverter & Rectifier without causing interruption to the critical load & thus there will be considerable energy savings during regeneration transients. Regenerative Power Regenerative Power fed to Mains
  • 21. Green Power Solution for Regenerative Load Application Liebert RG Dynamic Performance Connectivity Energy Saving Working Principle
  • 22. Energy saving during regenerative transients Liebert RG When using a Liebert RG UPS (Regenerative compatible power unit), the regenerative energy of a drive can be used by other loads, which saves energy. Liebert RG
  • 23. Energy saving during regenerative transients Regenerative Power Running Power Energy Saving Note : This is an example. Depend upon applications, trend may vary. Liebert RG
  • 24. Green Power Solution for Regenerative Load Application Liebert RG Dynamic Performance Connectivity Working principal Flexibility
  • 25. Connectivity options  UPS Monitoring Software (RS232 / Ethernet)  Remote Monitoring Panel (i-Remote Ethernet based)  SNMP  MODBUS Liebert RG
  • 26. UPS Monitoring Software Liebert RG  Mailing of the events via SMTP Protocol  Initiate graceful automation shutdown of the operating system and servers.  Auto Saving feature at the time of Shutdown for windows XP, Windows 2000 server and above.  Sequential shutdown of different servers at different timings  Multiple UPS Monitoring via serial port or through Ethernet  Notifies events through SMS messages  Supports to Window 98, Windows 2000 & Windows XP operating Systems  Log events to analyse performance of UPS & allied Hardware
  • 28. Remote Monitoring Panel – i-Remote Liebert RG  Selection & Monitoring of up to 4 UPS  Microprocessor based remote panel  Ethernet Connectivity  Auto detection software to set network parameters & UPS parameters  Keypad for user interface  Inbuilt Battery Backup  LCD Display & LED Indications  Compact Size : 195 (W) x 65(D) x 245 (H) in mm Features
  • 29. Remote Monitoring Panel – i-Remote Liebert RG LED Indications  UPS Selection  Inverter ON  Mains fails  Rectifier Trip  Load on Battery  Battery Low  Overload  Over Temperature  Inverter Trip  Load on Bypass  Alarm (Fault)
  • 30. SNMP (STOE card) Liebert RG  A small microprocessor based multifunction hardware  It facilitates monitoring of UPS through different systems supporting various networking protocols as like SNMP, TCP/IP, HTTP.  It has different ports for connectivity with the network.  One RJ45 10 Mbps Ethernet port  One RS232 output port  Operates as a server for different monitoring protocols  Setting of network configuration parameters through Detection Software  Trap generation through SNMP on different faults Features