SlideShare a Scribd company logo
TABLE
                OF
       FLASHCODES
FOR FAULT MEMORIES




       SD 206-2.97 e
        Page 1 of 62
Note:

For notes on setting and repair of individual systems please
consult the Repair Manuals or the relevant Service Infor-
mation sheets.

Notes/additions




SD 206-2.97
Page 2 of 62
Index
ABS/ASR
⇒ 2E Bosch.........................................................................Page         4-5
⇒ 3E Bosch.........................................................................Page         6-7
⇒ 2M Bosch ........................................................................Page         8-9
⇒ 2M Stage 1 Bosch ...........................................................Page            10 - 11
⇒ CI 12 Bosch ....................................................................Page        12 - 15
⇒ Knorr ...............................................................................Page   16 - 17
⇒ Wabco "C".......................................................................Page        18 - 21
Running gear:
⇒ ECAS, buses...................................................................Page          22 - 24
⇒ ECAS, trucks...................................................................Page         26 - 27
⇒ EFR running gear control, trucks .....................................Page                  28 - 30
Gearboxes:
⇒ Automated pre-selector shift (AVS) .................................Page                    40 - 41
⇒ Renk Doromat .................................................................Page          42 - 43
⇒ SAMT B...........................................................................Page       44 - 45
⇒ Voith-Diwa 3....................................................................Page        46 - 47
⇒ Voith retarder ..................................................................Page       48 - 49
⇒ ZF HP 500.......................................................................Page        52 - 54
⇒ ZF retarder (Intarder).......................................................Page           50 - 51
Heating/air-conditioning
⇒ D1LCC/D3LCC, Eberspächer..........................................Page                      32 - 33
⇒ Heater controls, Dreiha....................................................Page             34 - 35
⇒ Air-conditioner, Behr........................................................Page           36 - 37
⇒ Heater/air-conditioner control, Wabco (ATC)...................Page                          38 - 39
⇒ Airtop 2000, Webasto......................................................Page                   31
Engine:
⇒ EDC M7 ..........................................................................Page       56 - 57
⇒ EDC MS5 ........................................................................Page        58 - 59
⇒ EMS 3.3 ..........................................................................Page           55
⇒ Speed limiter VDO AGB-S ..............................................Page                  60 - 61
⇒ Air injection, Wabco ........................................................Page                62

Door control, IFE ..................................................................Page          25


                                                                                     SD 206-2.97
                                                                                    Page 3 of 62
BOSCH ABS/ASR 2E
Reading out the fault memory
− Switch off ignition and connect up request button
− Switch on ignition and press button for more than 1 second
The fault codes are emitted in three blocks. The first block indicates which control unit
status (configuration) is set. In the second and third blocks the faults in the diagonals FL/RR
(second block) and FR/RL (third block) can be read out.
Pause between flashes ............................................................ approx. 0.5 s
Duration of flashes ................................................................... approx. 0.5 s
Pause between individual blocks ............................................. approx. 1.5 s

Example of flashcode: Flashcode 2 in Block 1 for an ABS unit,
                      flashcode 2 in Block 2 and flashcode 1 in
                      Block 3.



         Lamp in                         on
         request
         button
                                         off

                                                    Block 1          Block 2             Block 3


Erasing the fault memory
− Switch off ignition and connect up request button
− Press button and keep it pressed
− Switch on ignition and release button after > 3 seconds




SD 206-2.97
Page 4 of 62
Block 1:                                                                                                   Flashcode
ABS unit ................................................................................................................2
ABS unit with ASR engine control (not an MAN application)) ................................3
ABS unit with ASR brake control (not an MAN application) ...................................4
ABS unit with ASR brake and engine control....................................................5

Flashcodes 3 and 4 may be emitted if components are not connected up or are defective.

Block 2 (FL/RR) and Block 3 (FR/RL):
Fault type                                                                                                   Flashcode
No fault...................................................................................................................1
Control unit defective .............................................................................................2
Speed sensor signal path:
⇒ front: inadmissible gap ......................................................................................3
⇒ rear: inadmissible gap .......................................................................................4
⇒ front: crack or short-circuit .................................................................................6
⇒ rear: crack or short-circuit..................................................................................7
Undervoltage, or relay for pressure control valve cannot be triggered ..................9
Pressure control valve signal path:
⇒ front .................................................................................................................10
⇒ rear ..................................................................................................................11
Relay for pressure control valve cannot switch (sticking)) ...................................13
Signal path for ASR solenoid valve......................................................................14

Connection diagram for request button




              Bus X40                                 X201                  X202                                 X202
                 X124




                                                                                                                   SD 206-2.97
                                                                                                                  Page 5 of 62
BOSCH ABS/ASR 3E
Reading out the fault memory
− Switch off ignition and connect up request button
− Switch on ignition
− Press button for > 2 seconds
Blocks 1 and 2 indicate the configuration of the control unit. In Blocks 3 and 4 the faults in
the diagonals FL/CR/RL (Block 3) and FR/CL/RR (Block 4) can be read out.
Example of flashcode: Flashcode 2 in Block 1, Flashcode 2 in Block 2, Flashcode 3 in
Block 3 and Flashcode 1 in Block 4.

       Lamp in               on
       request
       button
                             off
                                        Block 1     Block 2      Block 3     Block 4



Erasing the fault memory
− Switch off ignition and connect up request button
− Press button and keep it pressed
− Switch on ignition and release button after > 3 seconds


Connection diagram for request button




         Bus X40                      X201            X202                       X202
            X124



SD 206-2.97
Page 6 of 62
Block 1:                                                                                                              Flashcode
ABS unit ............................................................................................................................2
ABS unit with ASR engine control (not an MAN application) .............................................3
ABS unit with ASR brake control at rear (not an MAN application)....................................4
ABS unit with ASR brake control at rear and engine control ......................................5
ABS unit with ASR brake control in centre (not an MAN application) ................................6
ABS unit with ASR brake control in centre and engine control
(not an MAN application)....................................................................................................7
ABS unit with ASR brake control at rear and in centre
(not an MAN application)....................................................................................................8
ABS unit with ASR brake control at rear and in centre and engine control
(not an MAN application)....................................................................................................9
Flashcodes 3, 4, 6, 7, 8 and 9 may occur if components are defective or not connected up.
Block 2:                                                                                      Flashcode
24 V operation, modified individual control on front axle ...................................................2

Block 3 (FL/CR/RL) and Block 4 (FR/CL/RR):
Type of fault                                                                                                           Flashcode
No fault...............................................................................................................................1
Control unit defective .........................................................................................................2
Speed sensor signal path:
⇒ front: inadmissible gap ..................................................................................................3
⇒ centre: inadmissible gap................................................................................................4
⇒ rear: inadmissible gap ...................................................................................................5
⇒ front: crack or short-circuit .............................................................................................6
⇒ centre: crack or short-circuit ..........................................................................................7
⇒ rear: crack or short-circuit..............................................................................................8
Undervoltage, or relay for pressure control valves cannot be triggered.............................9
Signal path for pressure control valve:
⇒ front .............................................................................................................................10
⇒ centre...........................................................................................................................11
⇒ rear ..............................................................................................................................12
Relay for pressure control valve cannot switch (sticking) ................................................13
Signal path for ASR solenoid valve..................................................................................14
Inadmissible configuration (incorrect solenoid valve may be fitted).................................15




                                                                                                                    SD 206-2.97
                                                                                                                   Page 7 of 62
BOSCH ABS/ASR 2M
Reading out the fault memory
− Switch off ignition and connect up request button
− Switch on ignition
− Press button for > 1 second
Blocks 1 and 2 indicate the configuration to which the control unit is set. In Blocks 3 and 4
the faults in the diagonals FL/RR (Block 3) and FR/RL (Block 4) can be read out.
Duration of a flash .................................................................... approx. 0,2 s
Pause between flashes ............................................................ approx. 0,4 s
Pause between blocks ............................................................. approx. 1,5 s
Example of flashcode: Flashcode 2 in Block 1, Flashcode 2 in Block 2,
                          Flashcode 3 in Block 3 and Flashcode 1 in Block 4.

       Lamp in                    on
       request
       button
                                  off
                                             Block 1      Block 2       Block 3      Block 4


Erasing the fault memory
− Switch off ignition and connect up request button
− Press button and keep it pressed
− Switch on ignition and release button after > 2 seconds
ASR check lamp:         Continually on: fault in servomotor path
                        Dimmed permanent light: fault in signal at terminal W

Gap recognition from control unit 81.25935-6410 onwards
− Drive vehicle at speed > 20 km/h
− Stop vehicle and switch off ignition
− Switch on ignition
⇒ Gap in order: ABS lamp continually on.
⇒ Gap enlarged: ABS lamp flashes 3 x and then remains continually on.
    Adjust speed sensors and accelerate vehicle several times from standstill
    to > 20 km/h so that the control unit can adjust to the change in the gaps.




SD 206-2.97
Page 8 of 62
Block 1:                                                                      Flashcode
ABS unit with HGB (from control unit 81.25935-6410)......................................2
ABS unit with ASR engine control and HGB (not an MAN application)..................3
ABS unit with ASR brake control (not an MAN application) ...................................4
ABS unit with ASR brake and engine control and HGB ...................................5
Flashcodes 3 and 4 may occur if components are defected or not connected up.
Block 2:                                                                           Flashcode
24 V operation: individual control modified on front axle .......................................2
Block 3 (FL/RR) and Block 4 (FR/RL):
Type of fault                                                                                                Flashcode
No fault...................................................................................................................1
Control unit defective .............................................................................................2
Speed sensor signal path:
⇒ front: inadmissible gap or short-circuit...............................................................3
⇒ rear: inadmissible gap or short-circuit ...............................................................4
⇒ front: crack or short-circuit .................................................................................5
⇒ rear: crack or short-circuit..................................................................................6
Undervoltage or relay for pressure control valve cannot be triggered ...................7
Pressure control valve signal path:
⇒ front ...................................................................................................................9
⇒ rear ..................................................................................................................10
Relay for pressure control valve cannot switch (sticking) ....................................13
Signal path for ASR solenoid valve......................................................................14

Connection diagram for request button




                  Bus X40                                 X201                 X202                                 X202
                     X124




                                                                                                                   SD 206-2.97
                                                                                                                  Page 9 of 62
BOSCH ABS/ASR 2M Stage 1
Reading out the fault memory
− Switch off ignition and connect up request button
− Switch on ignition
− Press button for > 1 second
Blocks 1 and 2 indicate the configuration to which the control unit is set. In Blocks 3 and 4
the faults in the diagonals FL/RR (Block 3) and FR/RL (Block 4) can be read out.
Duration of a flash ............................................................................................ approx. 0.2 s
Pause between flashes .................................................................................... approx. 0.4 s
Pause between blocks ..................................................................................... approx. 1.5 s
Example of flashcode: Flashcode 2 in Block 1, Flashcode 2 in Block 2,
                   Flashcode 3 in Block 3 and Flashcode 1 in Block 4.

         Lamp in                          on
         request
         button
                                          off
                                                           Block 1         Block 2          Block 3         Block 4


Erasing the fault memory
− Switch off ignition and connect up request button
− Press button and keep it pressed
− Switch on ignition and release button after > 3 seconds
Connection diagram for request button




              Bus X40                           X201             X202                          X202




SD 206-2.97
Page 10 of 62
Block 1:                                                                                                                    Flashcode
ABS unit with HGB...............................................................................................................2
ABS unit with ASR engine control and HGB (not an MAN application)..................................3
ABS unit with ASR brake control and HGB (not an MAN application) ...................................4
ABS unit with ASR brake and engine control and HGB ...................................................5
Flashcodes 3 and 4 may occur if components are defective or not connected up.
Block 2:                                                                                                                    Flashcode
24 V operation: individual control modified on front axle .......................................................2
Block 3 (FL/RR) and Block 4 (FR/RL):
Type of fault                                                                                                               Flashcode
No fault...................................................................................................................................1
Control unit defective .............................................................................................................2
Speed sensor signal path:
⇒ front: inadmissible gap or short-circuit...............................................................................3
⇒ rear: inadmissible gap or short-circuit ...............................................................................4
⇒ front: crack or short-circuit .................................................................................................6
⇒ rear: crack or short-circuit..................................................................................................7
Undervoltage or relay for pressure control valves cannot be triggered..................................9
Pressure control valve signal path:
⇒ front .................................................................................................................................10
⇒ rear ..................................................................................................................................11
Relay for pressure control valve cannot switch (sticking) ....................................................13
Signal path for ASR control valve ........................................................................................14
Fault in servomotor ..............................................................................................................15
Fault in C3/B7-Signal ...........................................................................................................16
Fault in signal at terminal W ................................................................................................17
Wheel equalisation difference too large...............................................................................18
Fault in signal path for relay for engine brake/retarder switch-off
(emission possible only in Block 4) ......................................................................................19
Fault in signal path for clutch switch ....................................................................................20
Gap recognition
− Drive vehicle at > 20 km/h
− Stop vehicle and switch off ignition
− Switch on ignition
  ⇒ Gap in order: ABS lamp is continually on.
  ⇒ Gap enlarged: ABS lamp flashes 3x and then remains continually on.
     Adjust speed sensors and accelerate vehicle several times from standstill to > 20 km/h
     so that the control unit can adjust to the changed gaps.




                                                                                                                 SD 206-2.97
                                                                                                                Page 11 of 62
BOSCH ABS/ASR CI 12
Reading out the fault memory
− Switch off ignition and connect up request button
− Switch on ignition
− Wait for 2 seconds and then press button for at least 2 seconds.
The flashcodes are emitted in two blocks. Block 1 indicates the configuration to which the
control unit is set. Block 2 indicates the actual fault code. Each fault code must be re-
quested individually.
Pause before first flash .................................................................................... approx. 3 s
Duration of a flash ............................................................................................ approx. 0.5 s
Pause between hundreds and tens or tens and units....................................... approx. 3 s
Pause between hundreds and hundreds .......................................................... approx. 1 s
Pause between tens and tens .......................................................................... approx. 1 s
Pause between units and units......................................................................... approx. 1 s
Example of flashcode: Flashcode 5 in Block 1, Flashcode 121 in Block 2.
         Lamp in                      on
         request
         button
                                      off

Erasing the fault memory                       Block 1                                           Block 2
− Switch off ignition and con-
  nect up request button
− Press the button
− Switch on ignition and keep button pressed for > 2 seconds
− Do not switch off ignition until at least 5 seconds have passed.
Connection diagram for request button




                                                                                     X202

SD 206-2.97
Page 12 of 62
Block 1:                                                                                                         Flashcode
Pure ABS unit, modified individual control on front axle.................................................2
ABS unit with ASR engine control (not an MAN application) .................................................3
ABS unit with ASR brake control (not an MAN application) ...................................................4
ABS unit with ASR brake and engine control....................................................................5
Pure ABS unit with Select-Low control on front axle
(not an MAN application)........................................................................................................6
ABS unit with Select-Low control on front axle and
ASR engine control (not an MAN application)........................................................................7
ABS unit with Select-Low control on front axle and
ASR brake control (not an MAN application) .........................................................................8
ABS unit with Select-Low control on front axle and
ASR brake and engine control (not an MAN application).......................................................9
Flashcodes 3, 4, 6, 7, 8 and 9 may occur if components are defective or not connected up.
Block 2:
Type of fault                                                                                                               Flashcode
No fault...............................................................................................................................121
CAN data bus:
⇒ BusOff, repair CAN bus .................................................................................................211
⇒ Tachograph signal, plausibility ......................................................................................212
⇒ Communication interrupted, repair CAN bus.................................................................213
⇒ Time-out, gearbox messages, repair CAN bus .............................................................214
⇒ Time-out, engine messages, repair CAN bus................................................................215
⇒ Time-out, retarder messages, repair CAN bus..............................................................216
Brake light switch not yet actuated, check cabling.............................................................217
Control unit defective .........................................................................................................221
Control unit defective .........................................................................................................222
Control unit defective .........................................................................................................223
Control unit defective .........................................................................................................224
Control unit defective .........................................................................................................225
Control unit defective .........................................................................................................226
Control unit defective .........................................................................................................227
Configuration EEPROM parameters defective...................................................................228
Axle tyres or pulse ring incorrect........................................................................................232
Voltage supply to pressure control valve, undervoltage.....................................................242
Voltage supply to pressure control valve, interruption .......................................................243
Control unit defective .........................................................................................................244
Pressure control valve:
⇒ Earth, FR or RL, control unit output, short-circuit to earth .............................................251
⇒ Earth, FR or RL, control unit output, short-circuit to +UBatt ..........................................252
⇒ Earth, diagonal FR/RL, interruption (PIN X1, 12) ..........................................................253
⇒ Voltage supply, diagonal FR/RL, incorrect polarity of +/-..............................................254
⇒ Earth, FL or RR, control unit output, short-circuit to earth .............................................255
⇒ Earth, FL or RR, control unit output, short-circuit to +UBatt ..........................................256




                                                                                                                SD 206-2.97
                                                                                                               Page 13 of 62
Pressure control valve:
⇒ Earth, diagonal FL/RR, interruption (PIN X1, 11) ..........................................................257
⇒ Voltage supply, diagonal FL/RR, incorrect polarity of +/-..............................................258
Speed sensors:
⇒ RL, interruption/short-circuit ..........................................................................................312
⇒ RL, pulse ring defective, gap too large..........................................................................316
⇒ FL, interruption/short-circuit...........................................................................................322
⇒ FL, pulse ring defective, gap too large ..........................................................................326
⇒ RR, interruption/short-circuit..........................................................................................342
⇒ RR, pulse ring defective, gap too large .........................................................................346
⇒ FR, interruption/short-circuit ..........................................................................................362
⇒ FR, pulse ring defective, gap too large..........................................................................366
⇒ RL, interturn fault, gap, pole wheel, signal ....................................................................411
⇒ RL, tyres or pulse ring incorrect ....................................................................................415
⇒ FL, interturn fault, gap, pole wheel, signal.....................................................................421
⇒ FL, tyres or pulse ring incorrect.....................................................................................425
Speed sensors:
⇒ RR, interturn fault, gap, pole wheel, signal....................................................................441
⇒ RR, tyres or pulse ring incorrect....................................................................................445
⇒ FR, interturn fault, gap, pole wheel, signal ....................................................................461
⇒ FR, tyres or pulse ring incorrect ....................................................................................465
Pressure control valve:
⇒ FL, inlet valve, interruption ............................................................................................512
⇒ FL, inlet valve, short-circuit to earth ..............................................................................513
⇒ FL, inlet valve, short-circuit to +UBatt ...........................................................................514
⇒ FL, earth connection, interruption..................................................................................515
⇒ FL, outlet valve, interruption ..........................................................................................516
⇒ FL, outlet valve, short-circuit to earth ............................................................................517
⇒ FL, outlet valve, short-circuit to +UBatt .........................................................................518
⇒ RL, inlet valve, interruption............................................................................................522
⇒ RL, inlet valve, short-circuit to earth ..............................................................................523
⇒ RL, inlet valve, short-circuit to +UBatt ...........................................................................524
⇒ RL, earth connection, interruption..................................................................................525
⇒ RL, outlet valve, interruption..........................................................................................526
⇒ RL, outlet valve, short-circuit to earth............................................................................527
⇒ RL, outlet valve, short-circuit to +UBatt.........................................................................528
⇒ RR, inlet valve, interruption ...........................................................................................532
⇒ RR, inlet valve, short-circuit to earth .............................................................................533
⇒ RR, inlet valve, short-circuit to +UBatt ..........................................................................534
⇒ RR, earth connection, interruption.................................................................................535
⇒ RR, outlet valve, interruption .........................................................................................536
⇒ RR, outlet valve, short-circuit to earth ...........................................................................537
⇒ RR, outlet valve, short-circuit to +UBatt ........................................................................538
⇒ FR, inlet valve, interruption............................................................................................552


SD 206-2.97
Page 14 of 62
Block 2:
Type of fault                                                                                                           Flashcode
Pressure control valve:
⇒ FR, inlet valve, short-circuit to earth..............................................................................553
⇒ FR, inlet valve, short-circuit to +UBatt...........................................................................554
⇒ FR, earth connection, interruption .................................................................................555
⇒ FR, outlet valve, interruption .........................................................................................556
⇒ FR, outlet valve, short-circuit to earth............................................................................557
⇒ FR, outlet valve, short-circuit to +UBatt.........................................................................558
⇒ FL, short-circuit to another valve ...................................................................................611
⇒ FL, incorrectly configured ..............................................................................................616
⇒ RL, short-circuit to another valve...................................................................................621
⇒ RR, short-circuit to another valve ..................................................................................631
⇒ FR, short-circuit to another valve...................................................................................651
⇒ FR, incorrectly configured .............................................................................................656
ASR solenoid valve:
⇒ Interruption ....................................................................................................................712
⇒ Short-circuit to earth ......................................................................................................713
⇒ Short-circuit to +UBatt ...................................................................................................714
⇒ Short-circuit to another valve.........................................................................................721
⇒ Recognised but not configured......................................................................................726
Interaxle lock/shut-off valve, short-circuit to earth..............................................................811
Interaxle lock/shut-off valve, short-circuit to +UBatt ...........................................................812
Engine interface:
⇒ DKR, short-circuit to earth or +UBatt.............................................................................813
⇒ DKV, actuator reports fault ............................................................................................814
⇒ DKV, interruption/short-circuit........................................................................................815
⇒ DKV, time-out ................................................................................................................816
Triggering of relay for engine brake/retarder:
⇒ Short-circuit to +UBatt ...................................................................................................817
⇒ Interruption or short-circuit to earth ...............................................................................818




                                                                                                            SD 206-2.97
                                                                                                           Page 15 of 62
KNORR ABS
Reading out the fault memory
− Switch off ignition and connect up request button
− Switch on ignition and wait for 2 seconds
− Press button for 2 seconds
The first block indicates the configuration to which the control unit is set. The second block
indicates the fault codes. Each fault code must be requested individually.
Duration of a ten............................................................................................... approx. 2 s
Duration of a unit .............................................................................................. approx. 0.5 s
Pause between tens and units ......................................................................... approx. 3 s
Pause between units and units......................................................................... approx. 1 s
Pause between tens and tens .......................................................................... approx. 1 s

Example of flashcode: Flashcode 2 in Block 1 and Flashcode 12 in Block 2.

         Lamp in                          on
         request
         button
                                          off
                                                       Block 1                Block 2

Erasing the fault memory
− Switch of ignition and connect up request button
− Press button and keep it pressed
− Switch on ignition and release it after > 2 seconds
Connection diagram for request button




                    X124                            X201               X202                            X202




SD 206-2.97
Page 16 of 62
Block 1:                                                                                                       Flashcode
ABS unit without ASR..........................................................................................................2
ABS unit with ASR engine control (not an MAN application) .................................................3
ABS unit with ASR brake control (not an MAN application) ...................................................4
ABS unit with ASR brake and engine control (not an MAN application) ................................5
Flashcodes 3, 4 and 5 may occur if components are defective or not connected up.
Block 2 (Diagonal 1 FR/RL, Diagonal 2 FL/RR):
Type of fault                                                                                                               Flashcode
No fault...................................................................................................................................1
Speed sensors:
⇒ FL, interruption or short-circuit.........................................................................................10
⇒ FL, gap too large, interturn fault, pole wheel fault ...........................................................11
⇒ FR, interruption or short-circuit ........................................................................................12
⇒ FR, gap too large, interturn fault, pole wheel fault...........................................................13
⇒ RL, interruption or short-circuit ........................................................................................14
⇒ RL, gap too large, interturn fault, pole wheel fault...........................................................15
⇒ RR, interruption or short-circuit........................................................................................16
⇒ RR, gap too large, interturn fault, pole wheel fault...........................................................17
Pressure control valve:
⇒ FL, interruption or short-circuit.........................................................................................22
⇒ FR, interruption or short-circuit ........................................................................................23
⇒ RL, interruption or short-circuit ........................................................................................24
⇒ RR, interruption or short-circuit........................................................................................25
ASR brake valve, RL, interruption or short-circuit ................................................................28
ASR brake valve, RR, interruption or short-circuit ...............................................................29
ASR engine control, E-Gas/EDC interface fault...................................................................31
Relay voltage supply for pressure control valve:
⇒ Diagonal 1 cannot be switched off (contact sticking).......................................................32
⇒ Diagonal 1 cannot be switched off...................................................................................33
⇒ Diagonal 2 cannot be switched off (contact sticking).......................................................34
⇒ Diagonal 2 cannot be switched off...................................................................................35
ABS engine brake/retarder switch-off, interruption or short-circuit.......................................36
ABS warning lamp, tractor, interruption or short-circuit........................................................38
Switch-on time monitoring of valves (implausible triggering)...............................................52
ASR recognised but not configured......................................................................................53
Differences in wheel diameter too large...............................................................................54
Voltage supply for pressure-control valves, diagonal 1, overvoltage...................................56
Voltage supply for pressure-control valves, diagonal 2, overvoltage...................................57
Speed recording, signals with frequency > 1500 Hz, unwanted signals ..............................91
Pressure control valves, bleeding and holding times too long .............................................92
Configuration error (defective EEPROM parameters)..........................................................98
Control unit defective ...........................................................................................................99




                                                                                                                 SD 206-2.97
                                                                                                                Page 17 of 62
WABCO „C“ ABS/ASR
Reading out the fault memory
− Switch-off ignition and connect up request switch
− Switch on ignition and wait for 2 seconds
− Close the switch
If the switch is opened the fault entry in the fault memory will be erased. Switching off the
ignition before the switch is opened ends the flashcode emission without erasing the fault in
the fault memory. The first block is a "starting block"; this begins the fault code emission.
The second block indicates the configuration to which the control unit is set. Blocks 3 and 4
indicate the actual fault codes. The flashcode emission may be deactivated (ended) only in
the pauses between the constantly repeated flashcodes.
Duration of starting block ................................................................................. approx. 2.5 s
Pause between blocks ..................................................................................... approx. 2.5 s
Duration of a flash ............................................................................................ approx. 0.5 s
Pause between flashes .................................................................................... approx. 0,5 s
Example of flashcode: Starting block (Block1), Flashcode 2 in Block 2,
                              Flashcode 6 in Block 3 and Flashcode 6 in Block 4.

         Lamp in                  on
         request
         switch
                                  off
                                             Block 1 Block 2                 Block 3                    Block 4
Erasing the fault memory
− Switch off ignition and connect up request switch
− Switch on ignition and wait for 2 seconds
− Close the switch
− Open the switch during flashcode emission.

Connection diagram for request switch




                                                                                  X202
SD 206-2.97
Page 18 of 62
Block 2:
                                                                                                                  Flashcode
ABS system 6S/6K.................................................................................................................1
ABS system 4S/4K.................................................................................................................2
ABS system 4S/3K.................................................................................................................3
ABS system 6S/4K.................................................................................................................4
ABS system 6S/3K.................................................................................................................5

Flashcodes 3, 4 and 5 may occur if parts are defective or not connected up.

Block 3 and Block 4:

Type of fault                                                                                                        Flashcode
                                                                                                          Block 3 Block 4
Valve relay FR/RL, undervoltage ...........................................................................6 .............6
Valve relay FL/RR, undervoltage ...........................................................................6 .............7
Speed sensor:
⇒ FR, wheel speed signal fault (failure) ................................................................6 .............8
⇒ FL, wheel speed signal fault (failure).................................................................6 .............9
⇒ FR, interruption or short-circuit in cable ............................................................6 ...........10
⇒ FL, interruption or short-circuit in cable .............................................................6 ...........11
⇒ FR, wheel speed signal implausible..................................................................6 ...........12
⇒ FL, wheel speed signal implausible ..................................................................6 ...........13
⇒ RL, wheel speed signal fault (failure) ................................................................7 .............0
⇒ RR, wheel speed signal fault (failure)................................................................7 .............1
⇒ RL, interruption of short-circuit in cable.............................................................7 .............2
⇒ RR, interruption or short-circuit in cable ............................................................7 .............3
⇒ RL, wheel speed signal implausible ..................................................................7 .............4
⇒ RR, wheel speed signal implausible .................................................................7 .............5
⇒ ML, wheel speed signal fault (failure)................................................................7 .............8
⇒ MR, wheel speed signal fault (failure) ...............................................................7 .............9
⇒ ML, inadmissible impedance, interruption/short-circuit .....................................7 ...........10
⇒ MR, interruption or short-circuit in cable............................................................7 ...........11
⇒ ML, wheel speed signal implausible..................................................................7 ...........12
⇒ MR, wheel speed signal implausible .................................................................7 ...........13
Control unit defective .............................................................................................8 .............0
Control unit defective .............................................................................................8 .............1
ASR proportional valve (not an MAN application)..................................................8 .............2
ASR interface, DKR signal, interruption in cable (PIN 29) .....................................8 .............3
ASR proportional valve (not an MAN application)..................................................8 .............4
ASR interface, DKV signal, faulty data transfer (PIN 28) .......................................8 .............5
Interface for V signal (not an MAN application)......................................................8 .............6
ASR interface, DKV signal, interruption in cable (PIN 28) .....................................8 .............7
ASR interface, DKV signal, faulty data transfer (PIN 28) .......................................8 .............9




                                                                                                           SD 206-2.97
                                                                                                          Page 19 of 62
Type of fault                                                                                                   Flashcode
                                                                                                     Block 3 Block 4
Pressure control valve:
⇒ FR, inlet, short-circuit to earth ...........................................................................8 ...........10
⇒ FL, inlet, short-circuit to earth............................................................................8 ...........11
⇒ FR, inlet, interruption in cable............................................................................8 ...........12
⇒ FL, inlet, interruption in cable ............................................................................8 ...........13
⇒ FR, outlet, short-circuit to earth .........................................................................8 ...........14
⇒ FL, outlet, short-circuit to earth..........................................................................8 ...........15
⇒ FR, outlet, interruption in cable .........................................................................9 .............0
⇒ FL, outlet, interruption in cable ..........................................................................9 .............1
⇒ RL, inlet, short-circuit to earth ...........................................................................9 .............2
⇒ RR, inlet, short-circuit to earth...........................................................................9 .............3
⇒ RL, inlet, interruption in cable............................................................................9 .............4
⇒ RR, inlet, interruption in cable ...........................................................................9 .............5
⇒ RL, outlet, short-circuit to earth .........................................................................9 .............6
⇒ RR, outlet, short-circuit to earth.........................................................................9 .............7
⇒ RL, outlet, interruption in cable..........................................................................9 .............8
⇒ RR, outlet, interruption in cable .........................................................................9 .............9
⇒ ML, inlet, short-circuit to earth ...........................................................................9 ...........10
⇒ MR, inlet, short-circuit to earth ..........................................................................9 ...........11
⇒ ML, inlet, interruption in cable ...........................................................................9 ...........12
⇒ MR, inlet, interruption in cable...........................................................................9 ...........13
⇒ ML, outlet, short-circuit to earth.........................................................................9 ...........14
⇒ MR, outlet, short-circuit to earth ........................................................................9 ...........15
⇒ ML, outlet, interruption in cable .......................................................................10 .............0
⇒ MR, outlet, interruption in cable.......................................................................10 .............1
ASR valve RL, short-circuit to earth .....................................................................10 .............2
ASR valve RR, short-circuit to earth ....................................................................10 .............3
ASR valve RL, interruption in cable .....................................................................10 .............4
ASR valve RR, interruption in cable.....................................................................10 .............5
Retarder shut-off relay (PIN 11), short-circuit to +UBatt ......................................10 .............7
ASR engine control: inadmissible drive slip (EMS/EDC) .....................................10 .............8
ASR engine control: inadmissible drive slip (EMS/EDC) .....................................10 .............9
Pressure control valve:
⇒ FR, short-circuit to +UBatt or output stage defective.......................................11 ...........12
⇒ FL, short-circuit to +UBatt or output stage defective .......................................11 ...........13
⇒ RL, short-circuit to +UBatt or output stage defective.......................................11 ...........14
⇒ RR, short-circuit to +UBatt or output stage defective ......................................11 ...........15
⇒ ML, short-circuit to +UBatt or output stage defective ......................................12 .............0
⇒ MR, short-circuit to +UBatt or output stage defective......................................12 .............1
ASR valve RL, short-circuit to +UBatt or output stage defective..........................12 .............2
ASR valve RR, short-circuit to +UBatt or output stage defective .........................12 .............3
ASR proportional valve (not an MAN application)................................................12 .............4
Retarder shut-off relay (PIN 11), short-circuit to earth .........................................12 .............7


SD 206-2.97
Page 20 of 62
Type of fault                                                                                                       Flashcode
                                                                                                          Block 3 Block 4
Pressure control valve:
⇒ FR, short-circuit to +UBatt ...............................................................................12 .............8
⇒ FL, short-circuit to +UBatt................................................................................12 .............9
⇒ RL, short-circuit to +UBatt ...............................................................................12 ...........10
⇒ RR, short-circuit to +UBatt...............................................................................12 ...........11
⇒ ML, short-circuit to +UBatt...............................................................................12 ...........12
⇒ MR, short-circuit to +UBatt ..............................................................................12 ...........13
ASR valve RL, short-circuit to +UBatt ..................................................................12 ...........14
ASR valve RR, short-circuit to +UBatt .................................................................12 ...........15
ASR proportional valve (not an MAN application)................................................13 .............0
Valve relay RL/FR, relay contact sticking ............................................................13 .............4
Valve relay RR/FL, relay contact sticking ............................................................13 .............5
Control unit defective ...........................................................................................13 .............6
Control unit overvoltage, check alternator charge voltage ...................................13 .............7
Control unit defective ...........................................................................................13 .............8
Control unit defective ...........................................................................................13 .............9
Control unit defective ...........................................................................................13 ...........10
Control unit defective ...........................................................................................13 ...........11
Control unit defective ...........................................................................................13 ...........12
Control unit defective ...........................................................................................13 ...........13
Control unit defective ...........................................................................................13 ...........14
Control unit defective ...........................................................................................13 ...........15
Control unit defective ...........................................................................................14 .............0
Control unit defective ...........................................................................................14 .............1
Control unit defective ...........................................................................................14 .............2
Control unit defective ...........................................................................................14 .............3
Control unit defective ...........................................................................................14 .............4
Control unit defective ...........................................................................................14 .............5
Pressure control valve modulation RL/FR, switch-on time too long.....................14 .............6
Pressure control valve modulation RR/FL, switch-on time too long.....................14 .............7
ASR valve RL, switch-on time too long ................................................................14 .............8
ASR-valve RR, switch-on time too long ...............................................................14 .............9
Control unit defective ...........................................................................................14 ...........10
Control unit defective ...........................................................................................14 ...........11
Control unit defective ...........................................................................................14 ...........12
Control unit defective ...........................................................................................14 ...........13
Control unit defective ...........................................................................................14 ...........14
Control unit defective ...........................................................................................14 ...........15




                                                                                                          SD 206-2.97
                                                                                                         Page 21 of 62
ECAS air suspension for buses
Reading out the fault memory
− Switch off ignition and connect up request button
− Switch on ignition
− Wait for > 2 seconds and press button
Emission of the flashcode begins after 3 seconds. When the first flashcode has been emit-
ted further emission is automatically interrupted. For the next fault the button be pressed
again for at least 2 seconds.
Duration of a unit .............................................................................................. approx. 0.5 s
Duration of a ten............................................................................................... approx. 2 s
Pause between a ten and a unit ....................................................................... approx. 3 s
Pause between a unit and a unit ...................................................................... approx. 1 s
Pause between a ten and a ten........................................................................ approx. 1 s
Example of flashcode: fault code 12

         Lamp in                          on
         request
         button
                                          off

Erasing the fault memory
− Switch off ignition and connect up request button
− Press button and keep it pressed
− Switch on ignition and release button after > 2 seconds
In vehicles with 2 ECAS control units (articulated buses) each control unit must be read
and/or erased separately. For this the 35-pole plug on the control unit not affected must be
pulled out when the ignition is switched off.
Connection diagram for request button




              X201                X203                                X203

SD 206-2.97
Page 22 of 62
Type of fault                                                                                                     Flashcode
Internal fault in control unit:
⇒ Control unit defective.........................................................................................................1
⇒ Cumulative test fault in calibration data, recalibrate displacement sensors......................2
⇒ Control unit defective.........................................................................................................3
⇒ Control unit defective.........................................................................................................4
⇒ Control unit defective.........................................................................................................5
⇒ Control unit defective.........................................................................................................6
⇒ Cumulative test fault in calibration data, recalibrate pressure sensor ............................ (8)
⇒ Control unit or ECAS fuse, terminal 30, defective .............................................................9
Sensor fault, interruption or short-circuit to +UB:
⇒ Displacement sensor rear [front] right .............................................................................10
⇒ Displacement sensor rear [front] left ...............................................................................11
⇒ Displacement sensor front [centre]..................................................................................12
Pressure sensor, short-circuit to +UB ............................................................................... (15)
Anti-trap device contact strip, interruption or short-circuit to +UB..................................... (17)
Sensor fault, interruption or short-circuit to earth:
⇒ Displacement sensor rear [front] right .............................................................................20
⇒ Displacement sensor rear [front] left ...............................................................................21
⇒ Displacement sensor front [centre]..................................................................................22
Pressure sensor, short-circuit or interruption to earth ....................................................... (25)
Anti-trap device contact strip, short-circuit to earth ........................................................... (27)
Fault in solenoid valve, interruption or short-circuit to +UB:
⇒ Central solenoid valve, reservoir A * ...............................................................................30
⇒ Valve RA [FA] left C * ......................................................................................................31
⇒ Valve RA [FA] right B * ....................................................................................................32
⇒ Valve FA [CA] left F * ......................................................................................................33
⇒ Valve FA [CA] right E * ....................................................................................................34
⇒ Bus-stop brake valve.................................................................................................... (35)
⇒ Valve for primary current throttle .................................................................................. (39)
⇒ Valve, transverse throttle D *........................................................................................ (70)
Solenoid valve fault, interruption or short-circuit to earth:
⇒ Central solenoid valve, reservoir A * ...............................................................................40
⇒ Valve RA [FA] left C * ......................................................................................................41
⇒ Valve RA [FA] right B * ....................................................................................................42
⇒ Valve FA [CA] left F * ......................................................................................................43
⇒ Valve FA [CA] right E * ....................................................................................................44
⇒ Bus-stop brake valve.................................................................................................... (45)
⇒ Valve, primary current throttle ...................................................................................... (49)
⇒ Valve, transverse throttle D *........................................................................................ (71)
[ ] For the forebody of articulated buses the data in the square brackets apply.
( ) For vehicles with this equipment.
*    The letter is on the corrugated tube of the relevant valve.




                                                                                                         SD 206-2.97
                                                                                                        Page 23 of 62
Type of fault                                                                                                        Flashcode
Relay, door release:
⇒ Interruption or short-circuit to +UB ............................................................................... (36)
⇒ Short-circuit to earth ..................................................................................................... (46)
Plausibility fault (mechanical fault) during raising:
⇒ Displacement sensor rear [front] right .............................................................................50
⇒ Displacement sensor rear [front] left ...............................................................................51
⇒ Displacement sensor front [centre]..................................................................................52
Plausibility fault (mechanical fault) during lowering:
⇒ Displacement sensor rear [front] right .............................................................................60
⇒ Displacement sensor rear [front] left ...............................................................................61
⇒ Displacement sensor front [centre]..................................................................................62
Control unit defective ...........................................................................................................80
Speed signal interruption or short-circuit to +UB .................................................................81

[]     For the forebodies of articulated buses the data in square brackets apply.
()     For vehicles with this equipment.
*      The letter is on the corrugated tube of the relevant valve.




SD 206-2.97
Page 24 of 62
Door control system IFE
Reading out the fault memory
− Switch off ignition and connect up request button
− Switch on ignition
− Press button for > 2 seconds

Duration of a ten............................................................................................... approx. 2 s
Duration of a unit .............................................................................................. approx. 0.5 s
Pause between a ten and a unit ....................................................................... approx. 3 s
Pause between a unit and a unit ...................................................................... approx. 1 s

Example of flashcode: Fault code 11


          Lamp in                          on
          request
          button                           off
Erasing the fault memory
− Switch off ignition and connect up request button
− Press button and keep it pressed
− Switch on ignition and release button after > 2 seconds

Type of fault                                                                                              Flashcode
Break in connecting cable from door motor ...........................................................................1
Inward-swinging door: more than 10 seconds to reach fully open position.......................... *2
Slide-glide door: limit switch reports door closed, door displacement
sensor report displacement pulses ...................................................................................... *2
Door does not unlock within 3 seconds..................................................................................3
Inward-swinging door: more than 10 seconds to reach fully closed position ....................... *4
Slide-glide door: fault in door displacement sensor ............................................................. *4
Door monitoring in opening direction responded 3x during opening ......................................5
Motor current monitor responded at 5 closing procedures in succession ..............................6
Short-circuit at one output of door control system..................................................................7
Fault in pressure wave switch (responded continuously for more than 1 minute)..................8
Fault in electronic eye (responded continuously for more than 1 minute) ..............................9
Fault in door opening button (actuated continuously for more than 1 minute)......................10
Fault in driver’s button (actuated continuously for more than 1 minute) ...............................11


* Slide-glide door and inward-swinging door have the same fault code number
Flashcodes 1, 2, 3 and 4 lead to switch-off of door motor.




                                                                                                         SD 206-2.97
                                                                                                        Page 25 of 62
ECAS air suspension for trucks
Reading out the fault memory
− Switch off ignition and connect up request button
− Switch on ignition
− Press button for > 2 seconds
Emission of the flashcode begins after 3 seconds. After emission of the first fault further
emission is automatically interrupted. For the next fault the button must be pressed again for
at least 2 seconds.
Duration of a unit .............................................................................................. approx. 0.5 s
Duration of a ten............................................................................................... approx. 2 s
Pause between a ten and a unit ....................................................................... approx. 3 s
Pause between a unit and a unit ...................................................................... approx. 1 s
Pause between a ten and a ten........................................................................ approx. 1 s

Example of flashcode: Fault code 12
         Lamp in                          on
         request
         button
                                          off

Erasing the fault memory
− Switch off ignition and connect up request button
− Press button and keep it pressed
− Switch on ignition and release button after at least 2 and at most 4 seconds

Connection diagram for request button




X201               X203                               X203




SD 206-2.97
Page 26 of 62
4x2             6x2
Type of fault                                                                                                               Flashcode
Control unit defective ....................................................................................................1 ............. 1
Cumulative test fault in calibration data (recalibrate displacement sensors)...................2 ............. 2
Control unit defective.......................................................................................................3 ............. 3
Control unit defective.......................................................................................................4 ............. 4
Control unit defective.......................................................................................................5 ............. 5
Control unit defective.......................................................................................................6 ............. 6
Control unit defective....................................................................................................... - ............ *7
Pressure switch, moving-off aid/empty run ...................................................................... - ............. 8
Control unit or ECAS fuse, terminal 30 defective ............................................................ - ............. 9
Sensor fault, interruption or short-circuit to +UB:
⇒ Displacement sensor RR ..........................................................................................10 ........... 10
⇒ Displacement sensor RL...........................................................................................11 ........... 11
⇒ Displacement sensor, front .......................................................................................12 ........... 12
Sensor fault, short-circuit to earth:
⇒ Displacement sensor RR ..........................................................................................14 ........... 20
⇒ Displacement sensor RL...........................................................................................15 ........... 21
⇒ Displacement sensor, front .......................................................................................16 ........... 22
Valve fault, interruption or short-circuit to +UB:
⇒ Central solenoid valve, reservoir ..............................................................................20 ........... 30
⇒ Solenoid valve, RA or drive axle left.........................................................................21 ........... 31
⇒ Solenoid valve, RA or drive axle right ......................................................................22 ........... 32
⇒ Solenoid valve, lowering/burdening lifting/trailing axle.............................................. -- ........... 33
⇒ Solenoid valve, raising/relieving lifting/trailing axle ................................................... -- ........... 34
⇒ Solenoid valve, front axle .........................................................................................23 ........... 36
⇒ ALB control ...............................................................................................................24 ........... 35
⇒ Solenoid valve, lifting bellows.................................................................................... -- ........... 37
Valve fault, interruption or short-circuit to earth:
⇒ Central solenoid valve, reservoir ..............................................................................30 ........... 40
⇒ Solenoid valve, RA or drive axle left.........................................................................31 ........... 41
⇒ Solenoid valve, RA or drive axle right ......................................................................32 ........... 42
⇒ Solenoid valve, lowering/burdening lifting/trailing axle.............................................. -- ........... 43
⇒ Solenoid valve, raising/relieving lifting/trailing axle ................................................... -- ........... 44
⇒ Solenoid valve, front axle .........................................................................................33 ........... 46
⇒ Solenoid valve, lifting bellows.................................................................................... -- ........... 47
Plausibility fault (mechanical fault) during raising:
⇒ Displacement sensor, RR .........................................................................................40 ........... 50
⇒ Displacement sensor, RL..........................................................................................41 ........... 51
⇒ Displacement sensor, front .......................................................................................42 ........... 52
Plausibility fault (mechanical fault) during lowering:
⇒ Displacement sensor, RR .........................................................................................44 ........... 60
⇒ Displacement sensor, RL..........................................................................................45 ........... 61
⇒ Displacement sensor, front .......................................................................................46 ........... 62
Control unit defective...................................................................................................... -- .........**80
Speed signals interrupted or short-circuit to +UB........................................................... -- .........**81
* = up to control unit: 81.25935-6416; 466 055 041 0
** = from control unit 81.25935-6547; 466 055 047 0

                                                                                                                    SD 206-2.97
                                                                                                                   Page 27 of 62
EFR running-gear control for trucks
Reading out the fault memory
− Switch off ignition and connect up request button
− Switch on ignition
− Press button for > seconds
Emission of the flashcode begins after 3 seconds. After emission of the first fault further
emission in automatically interrupted. For the next fault the button must be pressed again for
at least 2 seconds.
Duration of a unit .............................................................................................. approx. 0.5 s
Duration of a ten............................................................................................... approx. 2 s
Pause between a ten and a unit ....................................................................... approx. 3 s
Pause between a unit and a unit ...................................................................... approx. 1 s
Pause between a ten and a ten........................................................................ approx. 1 s
Example of flashcode: Fault code 12
            Lamp in                       on
            request
            button
                                          off



Erasing the fault memory
− Switch off ignition and connect up request button
− Press button and keep it pressed
− Switch on ignition and release button after at least 2 and at most 4 seconds.
Connection diagram for request button




                                                                     X203

SD 206-2.97
Page 28 of 62
Electronics, 4x2, 6x2
Type of fault                                                                                                          Flashcode
Control unit defective .............................................................................................................1
Cumulative test error in calibration data, recalibrate displacement sensors..........................2
Control unit defective .............................................................................................................3
Control unit defective .............................................................................................................4
Control unit defective .............................................................................................................5
Control unit defective .............................................................................................................6
Cumulative test error in calibration data, recalibrate pressure sensors .................................8
Valve relay or ECAS fuse, terminal 30, defective ..................................................................9
Sensor fault, interruption or short-circuit to +UB:
⇒ Displacement sensor RR.................................................................................................10
⇒ Displacement sensor RL .................................................................................................11
⇒ Displacement sensor, front..............................................................................................12
Sensor fault, short-circuit to +UB:
⇒ Pressure sensor, drive axle right .....................................................................................13
⇒ Pressure sensor RA or drive axle left..............................................................................14
⇒ Pressure sensor, brake ...................................................................................................15
Sensor fault, short-circuit to earth:
⇒ Displacement sensor RR.................................................................................................20
⇒ Displacement sensor RL .................................................................................................21
⇒ Displacement sensor, front..............................................................................................22
Sensor fault, interruption or short-circuit to earth:
⇒ Pressure sensor, RA or drive axle right...........................................................................23
⇒ Pressure sensor, RA or drive axle left.............................................................................24
⇒ Pressure sensor, brake ...................................................................................................25
Valve fault, interruption or short-circuit to +UB:
⇒ Central solenoid valve, reservoir.....................................................................................30
⇒ Solenoid valve, RA or drive axle left ...............................................................................31
⇒ Solenoid valve, RA or drive axle right .............................................................................32
⇒ Solenoid valve, lowering/burdening lifting/trailing axle....................................................33
⇒ Solenoid valve, raising/relieving lifting/trailing axle.........................................................34
⇒ ALB control ......................................................................................................................35
⇒ Solenoid valve, front axle ................................................................................................36
⇒ Solenoid valve, dampers soft ..........................................................................................37
⇒ Solenoid valve, dampers medium ...................................................................................38




                                                                                                            SD 206-2.97
                                                                                                           Page 29 of 62
Electronics 4x2, 6x2
Type of fault                                                                                                          Flashcode
Valve fault, interruption or short-circuit to earth:
⇒ Central solenoid valve, reservoir.....................................................................................40
⇒ Solenoid valve, RA or drive axle left ...............................................................................41
⇒ Solenoid valve, RA or drive axle right .............................................................................42
⇒ Solenoid valve, lowering/burdening lifting/trailing axle....................................................43
⇒ Solenoid valve, raising/relieving lifting/trailing axle.........................................................44
⇒ ALB control ......................................................................................................................45
⇒ Solenoid valve, front axle ................................................................................................46
⇒ Solenoid valve, dampers soft ..........................................................................................47
⇒ Solenoid valve, dampers medium ...................................................................................48
Plausibility fault (mechanical fault) during raising:
⇒ Displacement sensor RR.................................................................................................50
⇒ Displacement sensor RL .................................................................................................51
⇒ Displacement sensor, front..............................................................................................52
Plausibility fault (mechanical fault) during lowering:
⇒ Displacement sensor RR.................................................................................................60
⇒ Displacement sensor RL .................................................................................................61
⇒ Displacement sensor, front..............................................................................................62
Control unit defective ...........................................................................................................80
Speed signals, interruption or short-circuit to +UB...............................................................81




SD 206-2.97
Page 30 of 62
WEBASTO auxiliary heater Airtop 2000

Reading out the fault memory
− The fault is shown automatically in the display when it occurs.

The faults are shown in the display of the control box. Only one fault can be displayed. If
more than one fault is present, the next fault will not be shown in the display until after the
first fault has been rectified.

Erasing the fault memory
− After repairs switch off the heater, wait for after-running and switch heater on again. The
  fault will be erased automatically.

Type of fault                                                                                                           Flashcode
No start, after 2 attempts to start...................................................................................... F 01
Flame interrupted, more than 5x within one heating cycle ............................................... F 02
Under/overvoltage............................................................................................................ F 03
Premature flame recognition ............................................................................................ F 04
Flame monitor, interruption or short-circuit ...................................................................... F 05
Temperature sensor for heater, interruption or short-circuit............................................. F 06
Metering pump, short-circuit............................................................................................. F 07
Blower motor, interruption/short-circuit or defective speed .............................................. F 08
Glow plug, interruption or short-circuit ............................................................................. F 09
Overheating...................................................................................................................... F 10




                                                                                                            SD 206-2.97
                                                                                                           Page 31 of 62
Eberspächer auxiliary heater D1LCC/D3LCC
Reading out the fault memory
− Switch off the auxiliary heater

− Switch on auxiliary heater with button                        .

− Press button               and with 2 seconds also press button                           .


The last fault to occur will be shown in the display, e.g.: AF:64

With buttons                and            a further four faults, if present, can be read out. E.g.: F:10,
F:13.

Erasing the fault memory
− Switch off the auxiliary heater-

− Switch on auxiliary heater with button                        .

− Press button               and within 2 seconds also press button                             .
− Open the 1-pole plug connection X 683, which is at the plug connection between wiring
  harness and control box.

− Press buttons                and           simultaneously and close plug connection X 683.
Type of fault                                                                                                          Fault code
No fault present............................................................................................................... (0)00
Control unit, chamber 1, to relay for fresh-air blower, short-circuit
to earth or control unit defective...................................................................................... (0)04
Control unit, chamber 2, to relay for electrical isolator switch or input for
anti-theft system, short-circuit to earth or control unit defective ...................................... (0)05
TRS switch-off due to signal change from plus to minus at control unit,
chamber 10, or plus at control unit, chamber 12 ............................................................. (0)09
Voltage between control unit chamber 5 and chamber 11:
⇒ Overvoltage > 31.8 V (30.4 V if glow plug switched on)............................................. (0)10
⇒ Undervoltage < 21 V (19 V if glow plug switched on)................................................. (0)11
Connection between control unit and overheating sensor: no continuity......................... (0)12
Overtemperature in flame sensor > 340° C or > 2270 Ω ............................................... (0)13
To many overheatings, control unit locked...................................................................... (0)15
Check glow plug (approx. 1 Ω to 2 Ω), control units chambers 6 and 9
to glow plug, interruption or control unit defective........................................................... (0)20
Glow plug or control unit, chamber 6, to glow plug: short-circuit
or control unit defective ................................................................................................... (0)21

If the fault code is read out with an Eberspächer diagnosis unit, it has 3 digits
(e.g. 021). If it is read out with the module clock, it has only 2 digits (e.g. 21).

SD 206-2.97
Page 32 of 62
Type of fault                                                                                                           Fault code
Control unit, chamber 4, to connection plug for module clock:
short-circuit to plus .......................................................................................................... (0)25
Burner motor or speed control defective: speed discrepancy ......................................... (0)33
Metering pump or control unit, chamber 3, to metering pump:
⇒ Short-circuit ................................................................................................................ (0)47
⇒ No continuity, check minus supply for metering pump ............................................... (0)48
Too many attempts to start, control unit locked .............................................................. (0)50
Flame already present at switch-on (flame sensor > 62° or >1240 Ω)............................ (0)51
No start, safety time exceeded........................................................................................ (0)52
Flame interrupted:
⇒ During starting ............................................................................................................ (0)53
⇒ At high speed.............................................................................................................. (0)54
⇒ At medium speed ....................................................................................................... (0)55
⇒ At low speed............................................................................................................... (0)56
External temperature control sensor:
⇒ Interruption > 2800 Ω.................................................................................................. (0)60
⇒ Short-circuit < 280 Ω .................................................................................................. (0)61
Control box potentiometer:
⇒ Interruption >2800 Ω (normal value 1750 Ω to 2080 Ω ±80 Ω) .................................. (0)62
⇒ Short-circuit < 280 Ω (normal value 1750 Ω to 2080 Ω ±80 Ω) .................................. (0)63
Flame sensor or flame sensor lead:
⇒ Interruption > 3200 Ω.................................................................................................. (0)64
⇒ Short-circuit < 200 Ω .................................................................................................. (0)65
Overheating sensor, interruption > 3200 Ω or short-circuit <200 Ω ................................ (0)71
Control unit defective ...................................................................................................... (0)90
External interference voltage .......................................................................................... (0)91
Control unit defective:
⇒ ROM error .................................................................................................................. (0)92
⇒ RAM error................................................................................................................... (0)93
⇒ EEPROM fault ............................................................................................................ (0)94
⇒ Internal temperature sensor defective ........................................................................ (0)96
⇒ Oscillator or undervoltage fault................................................................................... (0)97

If the fault code is read out with an Eberspächer diagnosis unit, it has 3 digits
(e.g. 021). If it is read out with the module clock, it has only 2 digits (e.g. 21).




                                                                                                             SD 206-2.97
                                                                                                            Page 33 of 62
DREIHA control box
Reading out the fault memory
− Switch on ignition
− Press buttons 1 and 2 simultaneously for > 2 seconds
After 3 seconds the flashcode is emitted via the check lamp 3 . After emission of the first
fault code the display is automatically interrupted. For the next fault code buttons 1 and
 2 must be pressed again for at least 2 seconds.
                                                                         3


                                                                                                  1




                                                                                                  2


Erasing the fault memory
−     Switch off ignition
−     Press buttons 1 and 2 simultaneously and keep them pressed
−     Switch on ignition and release buttons 1 and 2 after 2 seconds
Dark phase before emission ............................................................................ approx. 3 s
Duration of a ten............................................................................................... approx. 2 s
Duration of a unit .............................................................................................. approx. 0.5 s
Pause between a ten and a ten........................................................................ approx. 1 s
Pause between a ten and a unit ....................................................................... approx. 3 s
Pause between a unit and a unit ...................................................................... approx. 1 S

Example of flashcode: Fault code 12

                                             on
           Lamp 3 in
           control box
                                             off




SD 206-2.97
Page 34 of 62
Type of fault                                                                                                           Flashcode
Valve: (check cabling to heater or drive in heater)
⇒ Short-circuit .....................................................................................................................11
⇒ Interruption ......................................................................................................................12
⇒ Stepping error..................................................................................................................13
Button defective (change control box)..................................................................................21
Short-circuit in blower...........................................................................................................26
Interruption in blower............................................................................................................27
Passenger compartment flap drive: short-circuit..................................................................31
Passenger compartment flap drive: interruption ..................................................................32
Footwell flap drive: short-circuit ...........................................................................................33
Footwell flap drive: interruption ............................................................................................34
Window flap drive: short-circuit............................................................................................35
Window flap drive: interruption.............................................................................................36
Fresh-air flap: short-circuit ...................................................................................................37
Fresh-air flap: interruption ....................................................................................................38
Air-conditioning flap: short-circuit.........................................................................................39
Air-conditioning flap: interruption..........................................................................................41
Output:
⇒ V short-circuit ..................................................................................................................43
⇒ V interruption ...................................................................................................................44
⇒ W short-circuit .................................................................................................................45
⇒ W interruption..................................................................................................................46
⇒ X short-circuit...................................................................................................................47
⇒ X interruption ...................................................................................................................48
⇒ Y short-circuit...................................................................................................................49
⇒ Y interruption ...................................................................................................................51
⇒ Z short-circuit...................................................................................................................52
⇒ Z interruption ...................................................................................................................53
Fault in memory (change control box)..................................................................................54




                                                                                                             SD 206-2.97
                                                                                                            Page 35 of 62
BEHR air-conditioner

Reading out the fault memory

− Switch off ignition and connect up request button
− Switch on ignition
− Press button for at least 2 seconds

When the first fault code has been emitted display of further codes will be automatically in-
terrupted. for the next fault code the button must be pressed again for at least 2 seconds.

Duration of a ten............................................................................................... approx. 2 s
Duration of a unit .............................................................................................. approx. 0.5 s
Pause between a ten and a unit ....................................................................... approx. 3 s
Pause between a unit and a unit ...................................................................... approx. 1 s
Pause between a ten and a ten........................................................................ approx. 1 s
Pause before emission of flashcode ................................................................ approx. 3 s

Example of flashcode: Fault code 13


            Lamp in                      on
            request
            button
                                         off


Erasing the fault memory

− Switch off ignition and connect up request button
− Press button and keep it pressed
− Switch on ignition and release button after > 2 seconds




SD 206-2.97
Page 36 of 62
Type of fault                                                                                                              Flashcode
Temperature sensor:
⇒ Interior (IF): short-circuit to earth.......................................................................................1
⇒ Interior (IF): short-circuit to +UB or interruption.................................................................2
⇒ Exterior (AF): short-circuit to earth ....................................................................................3
⇒ Exterior (AF): short-circuit to +UB or interruption ..............................................................4
⇒ Heat exchanger (TF): short-circuit to earth........................................................................5
⇒ Heat exchanger (TF):short-circuit to +UB or interruption...................................................6
⇒ Evaporator (VF): short-circuit to earth ...............................................................................7
⇒ Evaporator (VF): short-circuit to +UB or interruption .........................................................8
Compressor coupling: short-circuit to earth, +UB or interruption ...........................................9
Water clock valve: short-circuit to earth or interruption........................................................11
Water clock valve: short-circuit to +UB ................................................................................12
Blower relay: short-circuit to earth or interruption .............................................................. *13
Blower relay: short-circuit to +UB....................................................................................... *14
Coding not stored in control unit...........................................................................................15
Coding stored does not correspond to the components dependent on the
control unit............................................................................................................................16

* For air-conditioner only

Connection diagram for request button




                    X201                     X204




                                                                                                                SD 206-2.97
                                                                                                               Page 37 of 62
WABCO ATC (Automatic Temperature Control) heater/air-conditioner control


Reading out the fault memory
− Switch off ignition and connect up request button
− Switch on ignition
− Press button for at least 2 seconds


When the first fault code has been emitted, display of further fault codes will be automati-
cally interrupted. For further codes the button must be pressed again for at least 2 seconds.

Duration of a ten............................................................................................... approx. 2 s
Duration of a unit .............................................................................................. approx. 0.5 s
Pause between a ten and a ten........................................................................ approx. 1 s
Pause between a ten and a unit ....................................................................... approx. 3 s
Pause between a unit and a unit ...................................................................... approx. 1 s
Pause before flashcode emission .................................................................... approx. 3 s


Example of flashcode: Fault code 13

            Lamp in                      on
            request
            button
                                         off


Erasing the fault memory
− Switch off ignition and connect up request button
− Press button and keep it pressed
− Switch on ignition
− Release button after > 2 seconds an < 4 seconds




SD 206-2.97
Page 38 of 62
Type of fault                                                                                                     Flashcode
Control unit defective (cumulative test fault, fan curves)........................................................1
Control unit defective (cumulative test fault, setting data)......................................................2
Spec. temperature transmitter, short-circuit to +UBatt ...........................................................3
Spec. temperature transmitter, short-circuit to earth/interruption in cable..............................4
Temperature sensor:
⇒ Evaporator, short-circuit to +UBatt ....................................................................................6
⇒ Evaporator, short-circuit to earth .......................................................................................7
⇒ evaporator, interruption in cable........................................................................................8
⇒ Inside air, short-circuit to +UBatt .......................................................................................9
⇒ Inside air, short-circuit to earth ........................................................................................10
⇒ Inside air, interruption in cable ........................................................................................11
⇒ Air outlet, short-circuit to +UBatt .....................................................................................12
⇒ Air outlet, short-circuit to earth ........................................................................................13
⇒ Air outlet, interruption in cable.........................................................................................14
⇒ External air, short-circuit to +UBatt..................................................................................15
⇒ External air, short-circuit to earth.....................................................................................16
⇒ External air, interruption in cable.....................................................................................17
Mode switch defective..........................................................................................................18
Control unit defective (cumulative test fault, calibration data)..............................................21

Connection diagram for request button




                  X204




                                                                                                        SD 206-2.97
                                                                                                       Page 39 of 62
Automated pre-selector shift (AVS)
Reading out the fault memory
− Turn rotary switch to neutral position
− Hold stalk switch in "Plus" position
The fault codes are emitted on the gear display as long as the stalk switch is held in the
"Plus" position.
Erasing the fault memory
− Possible only with MAN-cats
Type of fault                                                                                                         Display
Short-circuit to earth:
⇒ Solenoid valve Y6 (Y135)................................................................................................21
⇒ Solenoid valve Y1 (Y135)................................................................................................23
⇒ Solenoid valve Y2 (Y135)................................................................................................24
⇒ Solenoid valve Y3 (Y135)................................................................................................25
⇒ Solenoid valve Y4 (Y135)................................................................................................26
⇒ Solenoid valve Y5 (Y135)................................................................................................27
⇒ Solenoid valve Y8 (Y135)................................................................................................28
⇒ Lamp for substitute driving program switch (S167) .........................................................34
⇒ Solenoid valve, confirm (Y137) .......................................................................................35
⇒ Clutch retention valve (136).............................................................................................36
Interruption or short-circuit to +UB:
⇒ Solenoid valve Y6 (Y135)................................................................................................41
⇒ Solenoid valve Y1 (Y135)................................................................................................43
⇒ Solenoid valve Y2 (Y135)................................................................................................44
⇒ Solenoid valve Y3 (Y135)................................................................................................45
⇒ Solenoid valve Y4 (Y135)................................................................................................46
⇒ Solenoid valve Y5 (Y135)................................................................................................47
⇒ Solenoid valve Y8 (Y135)................................................................................................48
⇒ Lamp for substitute driving program switch (S167) .........................................................54
⇒ Solenoid valve, confirm (Y137) .......................................................................................55
⇒ Clutch retention valve (136).............................................................................................56
Gearbox in neutral signal missing / Gear engaged signal does not drop out.......................61
Gear engaged signal:
⇒ Missing during shifting.....................................................................................................62
⇒ Missing without shifting ...................................................................................................63
Group engaged signal does not drop out if group is engaged,
or drops out and is no longer present...................................................................................64
Group engaged signal drops out without shifting and is no longer present..........................65
Overrevving during gearshift ................................................................................................66
Gear engaged signal and gearbox in neutral signals present simultaneously .....................67
Voltage from actual value transmitter (B138) or duty factor of PWM interface:
⇒ too low (cable 74502) ......................................................................................................71
⇒ too high (cable 74502).....................................................................................................72


SD 206-2.97
Page 40 of 62
Type of fault                                                                                                                  Display
Supply voltage from actual value transmitter (B138):
⇒ too low .............................................................................................................................73
⇒ too high............................................................................................................................74
Battery voltage:
⇒ too low .............................................................................................................................75
⇒ too high............................................................................................................................76
Signal from speed pickup (B135) faulty ...............................................................................77
Signal from tachograph missing...........................................................................................78
Fault in stalk switch (S157) / pre-selector switch (S171) .....................................................81
Cable 40502 to display (A145) disturbed.............................................................................82
Short-circuit to earth (more detailed analysis not possible) .................................................83
Mechanical defect in gearbox/wrong control unit .................................................................84
Substitute driving program has been activated ....................................................................88
Control unit defective ...........................................................................................................91
Control unit defective ...........................................................................................................92
Control unit defective ...........................................................................................................93




                                                                                                               SD 206-2.97
                                                                                                              Page 41 of 62
RENK DOROMAT
Reading out the fault memory
− Switch off ignition and set gearbox to neutral
− Connect up request button
− Switch on ignition and press button for > 2.5 seconds

The fault codes are emitted only via the gearbox oil temperature check lamp.
If no fault has been stored, the gearbox oil temperature check lamp goes out after the lamp
test and remains out.
If a fault has been stored, the fault code will be emitted 6 seconds after the lamp test. The
display is interrupted automatically after the first fault code. For further fault codes the but-
ton must be pressed again for > 2.5 seconds.

Duration of a ten............................................................................................... approx. 2 s
Duration of a unit .............................................................................................. approx. 0.5 s
Dark period between a ten and a unit .............................................................. approx. 3 s
Dark period between a unit and a unit.............................................................. approx. 1 s
Dark period between a ten and a ten ............................................................... approx. 1 s

Example of flashcode: Fault code 13

           Lamp in                       on
           request
           button
                                         off

                                               2.5 seconds
                                               (lamp test)

Erasing the fault memory
− Switch off ignition and connect up request button
− Press button and keep it pressed
− Switch on ignition and release button after > 2 seconds




SD 206-2.97
Page 42 of 62
Type of fault                                                                                          Flashcode
1st gear solenoid defective, cable or output stage.................................................................1
2nd gear solenoid defective, cable or output stage................................................................2
3rd gear solenoid defective, cable or output stage ................................................................3
4th gear solenoid defective, cable or output stage.................................................................4
Reverse gear solenoid defective, cable or output stage ........................................................5
Converter solenoid defective, cable or output stage ..............................................................6
Gearbox PTO defective, cable or output stage ......................................................................7
Modulation solenoid 1 defective cable or output stage ..........................................................9
Neutral solenoid defective, cable or output stage ................................................................11
Drive pickup (engine speed) defective, cable, output stage or earth fault in pickup ............12
Output pickup (road speed) defective, cable, output stage or earth fault in pickup..............13
Engine brake defective, cable or output stage .....................................................................14
Temperature lamp defective cable or output stage..............................................................15
Starter interlock defective, cable or output stage .................................................................16
Locking solenoid defective, cable or output stage ...............................................................17
Modulation solenoid 2 defective, cable or output stage .......................................................18

Connection diagram for request button




                                               X201                  X211




                                                                                                SD 206-2.97
                                                                                               Page 43 of 62
SAMT B

Reading out the fault memory
− Switch off ignition, set gearbox to neutral, do not depress the clutch
− Switch on ignition
− Move gearshift lever to downshift position and hold it there
− Briefly switch ignition off and on again (once only)
− Read off fault codes at gear display, thereby keeping the gearshift lever in the downshift
  position. A buzzer sounds after the last fault code and the display switches back to neutral
− Release gearshift lever

Erasing the fault memory
− Switch off ignition and set gearbox to neutral. Do not depress the clutch
− Switch on ignition
− Move gearshift lever to downshift position and hold it there
− Briefly switch ignition off and on again twice
− When the fault memory has been erased a buzzer briefly sounds and "00" appears briefly
  in the display. After this the display returns to neutral
− Release gearshift lever

Type of fault                                                                                                           Flashcode
Relay for power supply K314:
⇒ Short-circuit in coil to earth............................................................................................. A0
⇒ Interruption in coil or short-circuit to +UBatt ................................................................... A1
Battery voltage too high ...................................................................................................... A2
Battery voltage too low........................................................................................................ A3
"Ignition on" signal missing ................................................................................................. A4
Voltage at XY switch unit too high....................................................................................... A5
Voltage at XY switch unit too low ........................................................................................ A6
Voltage supply for gearshift lever: short-circuit ................................................................... A7
Voltage supply for gear display, short-circuit ...................................................................... A8
Solenoid valve for low splitter range:
⇒ Short-circuit .................................................................................................................... B0
⇒ Interruption or short-circuit to +UBatt ............................................................................. B1
Solenoid valve for high splitter range:
⇒ Short-circuit .................................................................................................................... B2
⇒ Interruption or short-circuit to +UBatt ............................................................................. B3
Mechanical fault in slow splitter range ................................................................................ B4
Mechanical fault in high splitter range................................................................................. B5
"Splitter" switch defective.................................................................................................... B6
Solenoid valve for high range-change group:
⇒ Short-circuit .................................................................................................................... C0
⇒ Interruption or short-circuit to +UBatt ............................................................................. C1
Solenoid valve for low range-change group:
⇒ Short-circuit .................................................................................................................... C2
⇒ Interruption or short-circuit to +UBatt ............................................................................ C3

SD 206-2.97
Page 44 of 62
Type of fault                                                                                                            Flashcode
Mechanical fault in high range-change group...................................................................... C4
Mechanical fault in low range-change group....................................................................... C5
"Range-change" switch defective........................................................................................ C6
Short-circuit in solenoid valve for clutch or external short-circuit ........................................ D0
Interruption or short-circuit to +UBatt in solenoid valve for clutch....................................... D1
Fault in data cable between SAMT control unit in cab and SAMT control unit
on gearbox .......................................................................................................................... E0
Fault in CAN data bus:
⇒ between SAMT control unit and EDC control unit .......................................................... E1
⇒ between SAMT control unit and retarder control unit ..................................................... E2
⇒ between SAMT control unit and ABS/ASR control unit .................................................. E3
⇒ general communication fault, SAMT control unit switched off ........................................ E4
Fault in data cable between SAMT control unit and gear display,
or faulty data transfer ..........................................................................................................EE
Fault in SAMT control unit (cab).......................................................................................... F0
Fault in SAMT control unit (gearbox)................................................................................... F1
Current at X motor of XY switch unit ................................................................................... H0
Interruption or short-circuit to earth at X motor of XY switch unit ........................................ H1
X potentiometer outside normal operating range ................................................................ H2
"Gate selector rail" cannot be triggered .............................................................................. H3
Current at Y motor of XY switch unit ....................................................................................J0
Interruption or short-circuit to earth at Y motor of XY switch unit .........................................J1
Y potentiometer outside normal operating range .................................................................J2
One forward gear cannot be triggered .................................................................................J3
One reverse gear cannot be triggered .................................................................................J4
Neutral position cannot be triggered ....................................................................................J5
Signal from countershaft speed sensor missing...................................................................L0
Signal from mainshaft speed sensor missing.......................................................................L1
Signal from output shaft speed sensor missing....................................................................L2
Solenoid valve for gearbox brake:
⇒ Short-circuit .................................................................................................................... U0
⇒ Interruption or short-circuit to +UBatt ............................................................................. U1
Reservoir air pressure to gearbox too low .......................................................................... U2
Position of gearshift lever illogical; up- and downshift requested
simultaneously at SAMT control unit in cab or short-circuit to +UBatt ............................... U3




                                                                                                              SD 206-2.97
                                                                                                             Page 45 of 62
VOITH DIWA.3
Reading out the fault memory
− Switch off ignition and connect up request button
− Switch on ignition
− Press button for > 2 seconds
Emission of the flashcode begins after 3 seconds. When the first fault code has been emit-
ted emission of further codes is automatically interrupted. For the next fault the button must
be pressed again for at least 2 seconds.
Duration of a flash ............................................................................................ approx. 0.5 s
Pause between a hundred and a hundred........................................................ approx. 1 s
Pause between a hundred and a ten................................................................ approx. 3 s
Pause between a ten and a ten........................................................................ approx. 1 s
Pause between a ten and a unit ...................................................................... approx. 3 s
Pause between a unit and a unit ...................................................................... approx. 1 s

Example of flashcode: Fault code 221

                                          on
            Lamp in
            request
            button                        off

Erasing the fault memory
− Switch off ignition and connect up request button
− Press button and keep it pressed
− Switch on ignition and release button after > 2 seconds

Connection diagram for request button




                                                           X211


SD 206-2.97
Page 46 of 62
Type of fault                                                                                                               Flashcode
Sensor:
⇒ Input speed....................................................................................................................221
⇒ Output speed .................................................................................................................222
⇒ Turbine speed................................................................................................................223
⇒ Oil temperature..............................................................................................................224
Input clutch .........................................................................................................................331
Through clutch....................................................................................................................332
Clutch for 4th gear..............................................................................................................333
Pump brake........................................................................................................................334
Converter brake, small piston ............................................................................................335
Turbine brake .....................................................................................................................336
Pressure, converter outlet valve WP..................................................................................337
Pressure, converter outlet valve WR .................................................................................338
Converter brake, large piston.............................................................................................339
Control element REA1 .......................................................................................................341
Relays:
⇒ Control ...........................................................................................................................342
⇒ Converter brake.............................................................................................................343
⇒ Speed switch .................................................................................................................344
⇒ Reversing lights.............................................................................................................345
Button lighting ....................................................................................................................346
Bus-stop brake relay ..........................................................................................................347
Relay, adhesion display .....................................................................................................348
Central warning lamp .........................................................................................................358
Gearbox oil warning lamp ..................................................................................................359
Service brake .....................................................................................................................361
Parking brake .....................................................................................................................362
Load pickup........................................................................................................................363
Button.................................................................................................................................364
Control reset.......................................................................................................................391
Software .............................................................................................................................392
REA0 control element ........................................................................................................399
Monitoring controller...........................................................................................................451
Supply voltage....................................................................................................................481
Control pressure.................................................................................................................499




                                                                                                                SD 206-2.97
                                                                                                               Page 47 of 62
Voith-Retarder
Reading out the fault memory
− Retarder step switch in zero position. Switch off ignition and connect up request button
− Switch on ignition
− Press button for > 2 seconds
When the first fault code has been emitted, emission of further codes will be automatically
interrupted. For the next fault the button must be pressed again for at least 2 seconds.
Duration of a ten............................................................................................... approx. 2 s
Duration of a unit .............................................................................................. approx. 1 s
Dark phase....................................................................................................... approx. 1 s

Example of flashcode: Fault code 12

                                          on
            Lamp in
            request
            button                        off

Erasing the fault memory
− Retarder step switch in zero position. 0, Switch off ignition and connect up request button.
− Press button and keep it pressed
− Switch on ignition and release button after >2 seconds.

Connection diagram for request button




                                                                        X207

SD 206-2.97
Page 48 of 62
Type of fault                                                                                                       Flashcode
Relay, retarder operation in stages, short-circuit to earth ......................................................1
Output, relay for speed reduction, short-circuit to +UBatt ......................................................2
Engine brake relay, short-circuit to earth ...............................................................................3
LED output in stage switch, short-circuit to earth ...................................................................4
PIN X1/7, undervoltage (< 17,5 Volt) .....................................................................................5
PIN X1/7, overvoltage (> 32,5 Volt) .......................................................................................6
Water temperature sensor:
⇒ Interruption or short-circuit to UBatt (> 2000 Ohm) ...........................................................8
⇒ Short-circuit to earth (< 600 Ohm).....................................................................................9
Oil temperature sensor:
⇒ Interruption or short-circuit to UBatt (> 2000 Ohm) .........................................................11
⇒ Short-circuit to earth (< 600 Ohm)...................................................................................12
Stage switch:
⇒ Undefined switching status..............................................................................................13
⇒ Short-circuit to UBatt .......................................................................................................14
⇒ Short-circuit to earth ........................................................................................................15
Speedo signal, interruption ..................................................................................................16
Speedo signal, short-circuit to UBatt or undefined signal ....................................................18
ABS signal, short-circuit to earth..........................................................................................19
ABS signal, signal level undefined.......................................................................................21
ABS signal, internal fault in Digiprop control unit .................................................................22
Fault in prop. valve:
⇒ Short-circuit to UBatt at prop. valve, or control unit defective .........................................23
⇒ Short-circuit in prop. valve solenoid, short-circuit in prop. valve cable,
   interruption in prop. valve solenoid, interruption in prop. valve cable,
   short-circuit to earth at prop. valve ..................................................................................24
⇒ Control unit defective.......................................................................................................25
⇒ Control unit defective.......................................................................................................26
⇒ Control unit defective.......................................................................................................27
PIN X1/13, undervoltage (< 17.5 Volt) .................................................................................28
Internal fault relating to safety module .................................................................................29
Data record / parameters, faulty coding ...............................................................................31
Retarder operation lamp:
⇒ Interruption or short-circuit to earth .................................................................................32
⇒ Short-circuit to UBatt .......................................................................................................33
Engine speed signal missing................................................................................................34
Internal fault relating to ROM / EEPROM.............................................................................35




                                                                                                          SD 206-2.97
                                                                                                         Page 49 of 62
ZF-Retarder (Intarder)

Reading out the fault memory

− Switch off ignition and connect up request button
− Switch on ignition
− Press request button for > 2 seconds

The flashcode is emitted after 3 seconds. After the first fault code emission of further codes
is automatically interrupted. For the next fault code the button must be pressed again for at
least 2 seconds.

Duration of a ten............................................................................................... approx. 2 s
Duration of a unit .............................................................................................. approx. 1 s
Dark phase between a ten and a unit............................................................... approx. 2 s
Dark phase between a unit and a unit .............................................................. approx. 1 s
Dark phase between a ten and a ten................................................................ approx. 1 s

Example of flashcode: Fault code 22


Lamp in                      on
request
button
                             off




Erasing the fault memory

− Switch off ignition and connect up request button
− Press button and keep it pressed
− Switch on ignition and release button after > 2 seconds




SD 206-2.97
Page 50 of 62
Type of fault                                                                                                        Flashcode
Charge valve, interruption ....................................................................................................21
Intarder check lamp, interruption..........................................................................................22
Charge valve, short-circuit ...................................................................................................41
Intarder check lamp, short-circuit .........................................................................................42
Brake light, short-circuit........................................................................................................44
Coolant temperature sensor:
⇒ Short-circuit or < 1000 Ohm ............................................................................................51
⇒ Interruption or > 400 kOhm..............................................................................................55
Brake stage switch, signal combination implausible ............................................................66
Output speed sensor, interruption or short-circuit ................................................................77
Proportional solenoid, interruption .......................................................................................88
Overvoltage in vehicle electrics > +38Volt...........................................................................99

Connection diagram for request button




                      X201                     X207                                      X207




                                                                                                           SD 206-2.97
                                                                                                          Page 51 of 62
ZF HP500
Reading out the fault memory
− Switch off ignition and connect up request button
− Switch on ignition
− Press request button for > seconds
If no fault has been stored, the lamp goes out when the button is pressed. If a fault is pres-
ent, emission of the flashcode begins after 3 seconds. After emission of the first fault code
emission is automatically interrupted. For the next fault code the button must be pressed
again for at least 2 seconds.
Duration of a ten............................................................................................... approx. 2 s
Duration of a unit .............................................................................................. approx. 1 s
Dark phase between a ten and a unit............................................................... approx. 2 s
Dark phase between a unit and a unit .............................................................. approx. 1 s
Dark phase between a ten and a ten................................................................ approx. 1 s
Example of flashcode: Fault code 23

                             on
Lamp in
request
button                       off

Erasing the fault memory
− Switch off ignition and connect up request button
− Press button and keep it pressed
− Switch on ignition and release button after > 3 seconds
Connection diagram for request button




                         X201                  X211                                  X211


SD 206-2.97
Page 52 of 62
Type of fault                                                                                                                Flashcode
Slip fault ...............................................................................................................................11
Slipping time too long (gear change 1->2) ...........................................................................12
Slipping time too long (gear change 2-->3)..........................................................................13
Slipping time too long (gear change 3-->4)..........................................................................14
Slipping time too long (gear change 4-->5)..........................................................................15
Slipping time too long (gear change 5-->6)..........................................................................16
Slipping time too long (gear change 6-->7)..........................................................................17
Slipping time too long (gear change 7-->8)..........................................................................18
Load pickup faulty, tap voltage too high/low ........................................................................23
Output speed sensor faulty ..................................................................................................25
Turbine speed sensor faulty .................................................................................................27
Speedo output SD3:
⇒ Short-circuit to 24 Volt .....................................................................................................28
⇒ Short-circuit to earth ........................................................................................................29
Short-circuit to earth
⇒ Brake G, cable 45 AD1....................................................................................................31
⇒ Brake F, cable 44 AD 2 ...................................................................................................32
⇒ Brake E, cable 42 AD 3 ...................................................................................................33
⇒ Brake D, cable 39 AD 4...................................................................................................34
⇒ Clutch C, cable 4 AD 5 ....................................................................................................35
⇒ Clutch B, cable 22 AD 6 ..................................................................................................36
⇒ Clutch A, cable 3 AD 7 ....................................................................................................37
⇒ Converter clutch WK, cable 1 AD 8.................................................................................38
⇒ Retarder output, cable 49 AD 9 .......................................................................................39
⇒ Engine brake output, cable 50 AD 10..............................................................................40
⇒ Engine brake output, cable 53 AD 11..............................................................................41
⇒ V signal, cable 55 AD 12 .................................................................................................42
⇒ PTO output, cable 11 AD 13............................................................................................43
⇒ Antigas signal, cable 30 AD 14 .......................................................................................44
⇒ Load reduction/gear signal 1, cable 12 AD 15 ................................................................45
⇒ Bar magnet/fault display (H1), cable 54 AD 16 ...............................................................46
Interruption or short-circuit to 24 Volt
⇒ Brake G, cable G.............................................................................................................51
⇒ Brake F, cable F ..............................................................................................................52
⇒ Brake E, cable E..............................................................................................................53
⇒ Clutch D, cable D ............................................................................................................54
⇒ Clutch C, cable C ............................................................................................................55




                                                                                                                 SD 206-2.97
                                                                                                                Page 53 of 62
Type of fault                                                                                                        Flashcode
Interruption or short-circuit to 24 Volt
⇒ Clutch B, cable B.............................................................................................................56
⇒ Clutch A, cable A.............................................................................................................57
⇒ Converter clutch, cable WK.............................................................................................58
⇒ Retarder output, check lamp not working, cable 1 BN2 ..................................................59
⇒ Engine brake output, engine brake not working, cable 12 BN2.......................................60
⇒ Retarder reduction output, retarder not reduced, cable 632............................................61
⇒ V signal 1, cable 5 BN1 ...................................................................................................62
⇒ PTO output, cable 6 BN2.................................................................................................63
⇒ Antigas signal, cable 4 BN2 ............................................................................................64
⇒ Load reduction/gear signal 2, cable 9 BN2 .....................................................................65
⇒ Bar magnet/fault display (driving switch lamp), cable 15 BN2 ........................................66
Load pickup, incorrect setting ..............................................................................................71
Driving switch defective/interrupted .....................................................................................73
Vehicle electrics faulty .........................................................................................................75
Constricted pressure valve, fault at current output AI1 ........................................................77
Load pickup, supply voltage faulty .......................................................................................79




SD 206-2.97
Page 54 of 62
EMS 3.3

Reading out the fault memory

− Switch off ignition and connect up request button
− Switch on ignition and press button for > 1 second

The flashcode is emitted only via the E-Gas lamp, not via the lamp in the request button.

Erasing the fault memory

− Switch off ignition and connect up request button
− Press button and keep it pressed
− Switch on ignition and release button after > 1 second

Type of fault                                                                                                               Flashcode
No fault...................................................................................................................................1
Control unit defective .............................................................................................................2
Actuator check-back...............................................................................................................3
Pedal potentiometer 1, fault ...................................................................................................4
Actuator fault ..........................................................................................................................5
Pedal potentiometer, signal not identical with that from pedal potentiometer 2.....................6
Speed signal fault...................................................................................................................7
ASR interface fault .................................................................................................................8
Pedal potentiometer 2, fault ...................................................................................................9
Road speed fault (cruise control) .........................................................................................10
Actuator current, fault ...........................................................................................................11
Actuator, learning fault .........................................................................................................12
Speed signal (signal fault)....................................................................................................13
Control unit trigger to solenoid valve, engine stop is interrupted .........................................14

Connection diagram for request button




                    X70                              X201              X210                           X210


                                                                                                                 SD 206-2.97
                                                                                                                Page 55 of 62
EDC M7

Reading out the fault memory

− Switch off ignition and connect up request button
   − Diagram A for control units up to end of 990 (290/300/330 hp)
   − Diagram B for control unit from 1991 onwards (320/420 hp)
− Remove feet from clutch and brake pedals (otherwise the fault code will be erased)
− Switch on ignition
− Press button for > 2 seconds

After emission of the first fault code further emission is automatically interrupted. For the
further fault codes the button must be pressed again for at least 2 seconds.

Example of flashcode: Fault code 5

        Lamp in              on
        request
        button
                             off


Erasing the fault memory (290/300/330 hp with control units up to end of 1990)

− Switch off ignition and connect up request button in accordance with
  diagram (A)
− Switch on ignition
− Press request button and at the same time actuate clutch or brake pedal


Erasing the fault memory (320/420 hp with control units from 1991 onwards)

−   Switch off ignition and connect up request button in accordance with diagram (B)
−   Press button and keep it pressed
−   Switch on ignition
−   Release button after > 3 seconds




SD 206-2.97
Page 56 of 62
Type of fault                                                                                                           Flashcode
Pedal value transmitter defective...........................................................................................1
Fuel temperature sensor (only for 290/300/330 hp) ...............................................................2
Charge air temperature sensor ..............................................................................................3
System speed pickup in mechanism......................................................................................4
Boost pressure sensor ...........................................................................................................5
Control rod travel pickup in mechanism .................................................................................6
Coolant temperature sensor...................................................................................................7
Road speed pickup: no signal or fault in signal......................................................................8
Idling switch in pedal value transmitter faulty (with 320/420 hp only) ....................................9
Quantity mechanism, system deviation................................................................................10
Not occupied ........................................................................................................................11
Not occupied ........................................................................................................................12
Control unit defective ...........................................................................................................13
Auxiliary speed sensor: no signal (terminal W))...................................................................14
Control unit defective ...........................................................................................................15

Connection diagram for request button:


                              A                                               B




                              X116                               X201                       X210




                                                                                                             SD 206-2.97
                                                                                                            Page 57 of 62
EDC MS5
Reading out the fault memory
− Switch off ignition and connect up request button
− Switch on ignition
− Press button for > seconds
After emission of the first fault code further emission is automatically interrupted. For further
fault codes the button must be pressed again for at least 2 seconds.
Pause before first emission.............................................................................. approx. 3 s
Duration of a long flash .................................................................................... approx. 2 s
Duration of a short flash ................................................................................... approx. 0.5 s
Pause between two short flashes..................................................................... approx. 0.5 s
Pause between a long and a short flash .......................................................... approx. 5 s
Pause between two long flashes...................................................................... approx. 1 s
Example of flashcode: Fault code, 1x long, 4x short

           Lamp in                     on
           request
           button
                                       off

Erasing the fault memory
−   Switch off ignition and connect up request button
−   Press button and keep it pressed
−   Switch on ignition
−   Release button after > 2.5 seconds and < 10 seconds

Connection diagram for request button




         X201                  X210                                X210

SD 206-2.97
Page 58 of 62
Type of fault         Please observe SI 97 04 22/2                                                                       Flashcode
                                                                                                                    long          short
Pedal value transmitter ...........................................................................................- .............1
Charge air temperature sensor ...............................................................................- .............3
Primary speed sensor .............................................................................................- .............4
Boost pressure sensor ............................................................................................- .............5
Control rod recording in mechanism .......................................................................- .............6
Coolant temperature sensor....................................................................................- .............7
Road speed pickup .................................................................................................- .............8
Idling switch in pedal value transmitter ...................................................................- .............9
Quantity mechanism (system deviation) .................................................................- ...........10
Auxiliary speed sensor ............................................................................................- ...........14
Fuel temperature sensor ........................................................................................1 .............1
Battery undervoltage ..............................................................................................1 .............3
Brake proximity switch ...........................................................................................1 .............4
Clutch proximity switch...........................................................................................1 .............5
Control unit (computer link) ....................................................................................1 .............6
Overrevving............................................................................................................1 .............7
Start of injection, system deviation ........................................................................1 .............8
Boost pressure controller, system deviation ..........................................................1 .............9
Needle movement sensor ......................................................................................1 ...........10
Mechanical defect in needle movement sensor (needle sticks).............................1 ...........11
Multistage switch for torque limiter.........................................................................1 ...........12
Control element (stalk switch) ................................................................................1 ...........13
ASR interface .........................................................................................................1 ...........14
Control unit (CAN module) .....................................................................................1 ...........15
CAN signal, ASR2..................................................................................................2 .............1
CAN signal, gearbox control ..................................................................................2 .............3
Idling switch in pedal value transmitter, plausibility with brake ..............................2 .............4
Main relay...............................................................................................................2 .............5
Multistage switch, top speed ..................................................................................2 .............7
Atmospheric pressure sensor (in control unit)........................................................2 .............8
CAN signal from ASR to retarder ...........................................................................2 ...........10
CAN signal from gearbox to retarder .....................................................................2 ...........11
CAN signal from vehicle management to engine brake .........................................2 ...........12
CAN signal from vehicle management...................................................................2 ...........13
CAN signal from gearbox to EDC ..........................................................................2 ...........14
Control unit (computer after-running not completed, EHAB) ..................................3 .............1
Control unit defective (computer 1 defective).........................................................3 .............2
Control unit defective (computer 2 defective).........................................................3 .............3
External stop recording ..........................................................................................3 .............4
Boost pressure control VTG...................................................................................3 .............5
Intercooling bypass ................................................................................................3 .............6
After-running not complete .....................................................................................3 .............8
After-running watchdog fault ..................................................................................3 .............9




                                                                                                               SD 206-2.97
                                                                                                              Page 59 of 62
VDO speed limiter AGB-S
Reading out the fault memory
− Switch off ignition and connect up request button
− Switch on ignition and wait for 2 seconds
− Press button for > 2 seconds
Emission is automatically interrupted after emission of the first fault code. For further fault
codes the button must be pressed again for at least 2 seconds.
Dark phase before emission ............................................................................ approx. 3 s
Duration of long flash ....................................................................................... approx. 2 s
Duration of short flash ...................................................................................... approx. 0.5 s
Pause between a long and a short flash .......................................................... approx. 3 s
Pause between two short flashes..................................................................... approx. 1 s
Pause between two long flashes...................................................................... approx. 1 s

Example of flashcode: Fault code 1x long and 2x short flashes


         Lamp in                          on
         request
         button
                                          off

Erasing the fault memory
− Switch off ignition and connect up request button
− Press button and keep it pressed
− Switch on ignition and release button after > 2 seconds




SD 206-2.97
Page 60 of 62
Type of fault                                                                                                          Flashcode
                                                                                                                     long short
Clutch switch, if present .............................................................................................1 .........2
Road speed signal, cable, short-circuit to earth or cable
capacity too high ........................................................................................................2 .........2
Road speed signal, cable open or short-circuit to +UB or signal fault .......................2 .........4
Servomotor, potentiometer cable(s)...........................................................................3 .........1
Fault in signal path for terminal W .............................................................................3 .........2
Program fault, (control unit defective) ........................................................................3 .........3
Configuration error, data out of tolerance...................................................................3 .........5
Servomotor cable, short-circuit to +UB ......................................................................4 .........1
Servomotor cable, short-circuit to earth .....................................................................4 .........2
Servomotor, internal short-circuit ...............................................................................4 .........3
Servomotor or servomotor cable interrupted..............................................................4 .........4
Positioning fault, servomotor incorrectly adjusted......................................................4 .........5

Connection diagram for request button




          X201                        X210                                            X210




                                                                                                            SD 206-2.97
                                                                                                           Page 61 of 62
WABCO air injection
Reading out the fault memory
− Switch off ignition and connect up request button
− Switch on ignition
− Press button for at least 2 seconds
Erasing the fault memory
−   Switch off ignition and connect up request button
−   Press button and keep it pressed
−   Switch on ignition
−   Release button after > 2 seconds
Type of fault                                                                                                           Flashcode
Control unit defective:
⇒ Cumulative test, ROM .......................................................................................................1
⇒ Cumulative test, Wabco data ............................................................................................2
⇒ Cumulative test, parameters .............................................................................................3
⇒ RAM cells defective...........................................................................................................4
Solenoid valve path:
⇒ Short-circuit .......................................................................................................................5
⇒ Interruption ........................................................................................................................6

Connection diagram for request button




                      x201                   x208                                     x208




SD 206-2.97
Page 62 of 62

More Related Content

PDF
Allison 1000-2000 Series Service Manual.pdf
PDF
PDF
Caterpillar cat c13 industrial engine (prefix jr9) service repair manual (jr9...
PDF
Hitachi zaxis 350 lc excavator service repair manual
PPT
Ajuste de bomba vp44
PDF
Vw eos 2006 programa autodidáctico 379 - sistema eléctrico
PDF
Diagrama do motor isb
PDF
HITACHI 6UZ1 INTERIM TIER 4 COMPATIBLE ENGINE Service Repair Manual
Allison 1000-2000 Series Service Manual.pdf
Caterpillar cat c13 industrial engine (prefix jr9) service repair manual (jr9...
Hitachi zaxis 350 lc excavator service repair manual
Ajuste de bomba vp44
Vw eos 2006 programa autodidáctico 379 - sistema eléctrico
Diagrama do motor isb
HITACHI 6UZ1 INTERIM TIER 4 COMPATIBLE ENGINE Service Repair Manual

What's hot (20)

PDF
Man f2000 codes
PDF
Bt 50 en repair manual
PDF
Wiring diagram fm (euro5)
PDF
volvo wiring diagram vm
PDF
MANUAL ENGINE 1/2KD-FTV TOYOTA SISTEMA COMNON RAIL
PDF
Volvo wiring diagram fh
PDF
Electronic stability program (esp)
PDF
2AZ-FE.pdf
PPT
SCANIA SLIDE&APU-1.ppt
PDF
Codigos de falhas volvo fh12 d12 a
PDF
291 1 Cambio automatico 09G.pdf
PDF
Xl1000 varadero service manual
PDF
Toyota corolla-wiring-diagram-1998
PDF
Volvo manual
PDF
Volvo Fe Truck Wiring Diagram Service Manual Download June 2009
PDF
dr ecus null-1.pdf
PDF
C,12925439 toyota-coralla-1996-wiring-diagram-overall
PDF
Honda Cr125 R Service Manual Ita
Man f2000 codes
Bt 50 en repair manual
Wiring diagram fm (euro5)
volvo wiring diagram vm
MANUAL ENGINE 1/2KD-FTV TOYOTA SISTEMA COMNON RAIL
Volvo wiring diagram fh
Electronic stability program (esp)
2AZ-FE.pdf
SCANIA SLIDE&APU-1.ppt
Codigos de falhas volvo fh12 d12 a
291 1 Cambio automatico 09G.pdf
Xl1000 varadero service manual
Toyota corolla-wiring-diagram-1998
Volvo manual
Volvo Fe Truck Wiring Diagram Service Manual Download June 2009
dr ecus null-1.pdf
C,12925439 toyota-coralla-1996-wiring-diagram-overall
Honda Cr125 R Service Manual Ita
Ad

Viewers also liked (12)

PDF
Manuale MAN Truck
PDF
233399847 manual-instrumentos-construccion-funcion-camiones-fm-fh-volvo
PDF
Iveco workshop manual
PDF
Manual Volvo
PDF
Opel zafira 1.9 cdti edc 16 c-9
PDF
Scania
PDF
Davie diagnostics manual
DOC
Powertrain Codes DTC list
PDF
Ecas bus
PDF
manual de motor iveco cursor
PDF
Motor Scania Dc 12
PDF
A Guide to SlideShare Analytics - Excerpts from Hubspot's Step by Step Guide ...
Manuale MAN Truck
233399847 manual-instrumentos-construccion-funcion-camiones-fm-fh-volvo
Iveco workshop manual
Manual Volvo
Opel zafira 1.9 cdti edc 16 c-9
Scania
Davie diagnostics manual
Powertrain Codes DTC list
Ecas bus
manual de motor iveco cursor
Motor Scania Dc 12
A Guide to SlideShare Analytics - Excerpts from Hubspot's Step by Step Guide ...
Ad

Similar to Man f2000 codes (20)

PDF
Medrad Vistron CT Injection System - Service manual.pdf
PDF
Cummins onan dskaa generator set with power command 1.1 controller service re...
PDF
Cummins onan dskaa generator set with power command 1.1 controller service re...
PDF
Cummins onan dskab generator set with power command 1.1 controller service re...
PDF
Cummins onan dskba generator set with power command 1.1 controller service re...
PDF
Cummins onan dskaa generator set with power command 1.1 controller service re...
PDF
Cummins onan dskaa generator set with power command 1.1 controller service re...
PDF
Cummins onan dskca generator set with power command 1.1 controller service re...
PDF
Tv samsung cl21k40mqgxxaz_chassis_ks9c_n_ray
PDF
Manual completo ARM
PDF
10580 00089
PDF
Fanuc pmc programming manual
PDF
P2021 1 f7035
PDF
Cummins onan c80 generator set qsb5 engine with the power command 1.1r contro...
PDF
Cummins onan c80 generator set qsb5 engine with the power command 1.1r contro...
PDF
Cummins onan d6 r generator set qsb5 engine with the powercommand 1.1r contro...
PDF
Cummins onan c60 generator set qsb5 engine with the power command 1.1r contro...
PDF
Cummins onan d6 r generator set qsb5 engine with the powercommand 1.1r contro...
PDF
Cummins onan c100 generator set qsb5 engine with the power command 1.1r contr...
PDF
Acer espire es1 523 service guide manual tricera czl
Medrad Vistron CT Injection System - Service manual.pdf
Cummins onan dskaa generator set with power command 1.1 controller service re...
Cummins onan dskaa generator set with power command 1.1 controller service re...
Cummins onan dskab generator set with power command 1.1 controller service re...
Cummins onan dskba generator set with power command 1.1 controller service re...
Cummins onan dskaa generator set with power command 1.1 controller service re...
Cummins onan dskaa generator set with power command 1.1 controller service re...
Cummins onan dskca generator set with power command 1.1 controller service re...
Tv samsung cl21k40mqgxxaz_chassis_ks9c_n_ray
Manual completo ARM
10580 00089
Fanuc pmc programming manual
P2021 1 f7035
Cummins onan c80 generator set qsb5 engine with the power command 1.1r contro...
Cummins onan c80 generator set qsb5 engine with the power command 1.1r contro...
Cummins onan d6 r generator set qsb5 engine with the powercommand 1.1r contro...
Cummins onan c60 generator set qsb5 engine with the power command 1.1r contro...
Cummins onan d6 r generator set qsb5 engine with the powercommand 1.1r contro...
Cummins onan c100 generator set qsb5 engine with the power command 1.1r contr...
Acer espire es1 523 service guide manual tricera czl

Recently uploaded (20)

PPTX
Intro to ISO 9001 2015.pptx for awareness
PDF
industrial engineering and safety system
PDF
Journal Meraj.pdfuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuu
PDF
Volvo EC290C NL EC290CNL engine Manual.pdf
PDF
Renesas R-Car_Cockpit_overview210214-Gen4.pdf
PPT
Kaizen for Beginners and how to implement Kaizen
PDF
3-REasdfghjkl;[poiunvnvncncn-Process.pdf
PDF
Volvo EC290C NL EC290CNL Hydraulic Excavator Specs Manual.pdf
PDF
computer system to create, modify, analyse or optimize an engineering design.
PDF
Caterpillar Cat 315C Excavator (Prefix CJC) Service Repair Manual Instant Dow...
PPTX
Fire Fighting Unit IV industrial safety.pptx
PDF
Physics class 12thstep down transformer project.pdf
PDF
Todays Technician Automotive Heating & Air Conditioning Classroom Manual and ...
PDF
MANDIBLE (1).pdffawffffffffffffffffffffffffffffffffffffffffff
PDF
higher edu open stores 12.5.24 (1).pdf forreal
PPTX
IMMUNITY TYPES PPT.pptx very good , sufficient
DOCX
lp of food hygiene.docxvvvvvvvvvvvvvvvvvvvvvvv
PDF
Caterpillar CAT 311B EXCAVATOR (8GR00001-UP) Operation and Maintenance Manual...
PPTX
Robot_ppt_YRG[1] [Read-Only]bestppt.pptx
PDF
intrusion control for clean steel 123.pdf
Intro to ISO 9001 2015.pptx for awareness
industrial engineering and safety system
Journal Meraj.pdfuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuu
Volvo EC290C NL EC290CNL engine Manual.pdf
Renesas R-Car_Cockpit_overview210214-Gen4.pdf
Kaizen for Beginners and how to implement Kaizen
3-REasdfghjkl;[poiunvnvncncn-Process.pdf
Volvo EC290C NL EC290CNL Hydraulic Excavator Specs Manual.pdf
computer system to create, modify, analyse or optimize an engineering design.
Caterpillar Cat 315C Excavator (Prefix CJC) Service Repair Manual Instant Dow...
Fire Fighting Unit IV industrial safety.pptx
Physics class 12thstep down transformer project.pdf
Todays Technician Automotive Heating & Air Conditioning Classroom Manual and ...
MANDIBLE (1).pdffawffffffffffffffffffffffffffffffffffffffffff
higher edu open stores 12.5.24 (1).pdf forreal
IMMUNITY TYPES PPT.pptx very good , sufficient
lp of food hygiene.docxvvvvvvvvvvvvvvvvvvvvvvv
Caterpillar CAT 311B EXCAVATOR (8GR00001-UP) Operation and Maintenance Manual...
Robot_ppt_YRG[1] [Read-Only]bestppt.pptx
intrusion control for clean steel 123.pdf

Man f2000 codes

  • 1. TABLE OF FLASHCODES FOR FAULT MEMORIES SD 206-2.97 e Page 1 of 62
  • 2. Note: For notes on setting and repair of individual systems please consult the Repair Manuals or the relevant Service Infor- mation sheets. Notes/additions SD 206-2.97 Page 2 of 62
  • 3. Index ABS/ASR ⇒ 2E Bosch.........................................................................Page 4-5 ⇒ 3E Bosch.........................................................................Page 6-7 ⇒ 2M Bosch ........................................................................Page 8-9 ⇒ 2M Stage 1 Bosch ...........................................................Page 10 - 11 ⇒ CI 12 Bosch ....................................................................Page 12 - 15 ⇒ Knorr ...............................................................................Page 16 - 17 ⇒ Wabco "C".......................................................................Page 18 - 21 Running gear: ⇒ ECAS, buses...................................................................Page 22 - 24 ⇒ ECAS, trucks...................................................................Page 26 - 27 ⇒ EFR running gear control, trucks .....................................Page 28 - 30 Gearboxes: ⇒ Automated pre-selector shift (AVS) .................................Page 40 - 41 ⇒ Renk Doromat .................................................................Page 42 - 43 ⇒ SAMT B...........................................................................Page 44 - 45 ⇒ Voith-Diwa 3....................................................................Page 46 - 47 ⇒ Voith retarder ..................................................................Page 48 - 49 ⇒ ZF HP 500.......................................................................Page 52 - 54 ⇒ ZF retarder (Intarder).......................................................Page 50 - 51 Heating/air-conditioning ⇒ D1LCC/D3LCC, Eberspächer..........................................Page 32 - 33 ⇒ Heater controls, Dreiha....................................................Page 34 - 35 ⇒ Air-conditioner, Behr........................................................Page 36 - 37 ⇒ Heater/air-conditioner control, Wabco (ATC)...................Page 38 - 39 ⇒ Airtop 2000, Webasto......................................................Page 31 Engine: ⇒ EDC M7 ..........................................................................Page 56 - 57 ⇒ EDC MS5 ........................................................................Page 58 - 59 ⇒ EMS 3.3 ..........................................................................Page 55 ⇒ Speed limiter VDO AGB-S ..............................................Page 60 - 61 ⇒ Air injection, Wabco ........................................................Page 62 Door control, IFE ..................................................................Page 25 SD 206-2.97 Page 3 of 62
  • 4. BOSCH ABS/ASR 2E Reading out the fault memory − Switch off ignition and connect up request button − Switch on ignition and press button for more than 1 second The fault codes are emitted in three blocks. The first block indicates which control unit status (configuration) is set. In the second and third blocks the faults in the diagonals FL/RR (second block) and FR/RL (third block) can be read out. Pause between flashes ............................................................ approx. 0.5 s Duration of flashes ................................................................... approx. 0.5 s Pause between individual blocks ............................................. approx. 1.5 s Example of flashcode: Flashcode 2 in Block 1 for an ABS unit, flashcode 2 in Block 2 and flashcode 1 in Block 3. Lamp in on request button off Block 1 Block 2 Block 3 Erasing the fault memory − Switch off ignition and connect up request button − Press button and keep it pressed − Switch on ignition and release button after > 3 seconds SD 206-2.97 Page 4 of 62
  • 5. Block 1: Flashcode ABS unit ................................................................................................................2 ABS unit with ASR engine control (not an MAN application)) ................................3 ABS unit with ASR brake control (not an MAN application) ...................................4 ABS unit with ASR brake and engine control....................................................5 Flashcodes 3 and 4 may be emitted if components are not connected up or are defective. Block 2 (FL/RR) and Block 3 (FR/RL): Fault type Flashcode No fault...................................................................................................................1 Control unit defective .............................................................................................2 Speed sensor signal path: ⇒ front: inadmissible gap ......................................................................................3 ⇒ rear: inadmissible gap .......................................................................................4 ⇒ front: crack or short-circuit .................................................................................6 ⇒ rear: crack or short-circuit..................................................................................7 Undervoltage, or relay for pressure control valve cannot be triggered ..................9 Pressure control valve signal path: ⇒ front .................................................................................................................10 ⇒ rear ..................................................................................................................11 Relay for pressure control valve cannot switch (sticking)) ...................................13 Signal path for ASR solenoid valve......................................................................14 Connection diagram for request button Bus X40 X201 X202 X202 X124 SD 206-2.97 Page 5 of 62
  • 6. BOSCH ABS/ASR 3E Reading out the fault memory − Switch off ignition and connect up request button − Switch on ignition − Press button for > 2 seconds Blocks 1 and 2 indicate the configuration of the control unit. In Blocks 3 and 4 the faults in the diagonals FL/CR/RL (Block 3) and FR/CL/RR (Block 4) can be read out. Example of flashcode: Flashcode 2 in Block 1, Flashcode 2 in Block 2, Flashcode 3 in Block 3 and Flashcode 1 in Block 4. Lamp in on request button off Block 1 Block 2 Block 3 Block 4 Erasing the fault memory − Switch off ignition and connect up request button − Press button and keep it pressed − Switch on ignition and release button after > 3 seconds Connection diagram for request button Bus X40 X201 X202 X202 X124 SD 206-2.97 Page 6 of 62
  • 7. Block 1: Flashcode ABS unit ............................................................................................................................2 ABS unit with ASR engine control (not an MAN application) .............................................3 ABS unit with ASR brake control at rear (not an MAN application)....................................4 ABS unit with ASR brake control at rear and engine control ......................................5 ABS unit with ASR brake control in centre (not an MAN application) ................................6 ABS unit with ASR brake control in centre and engine control (not an MAN application)....................................................................................................7 ABS unit with ASR brake control at rear and in centre (not an MAN application)....................................................................................................8 ABS unit with ASR brake control at rear and in centre and engine control (not an MAN application)....................................................................................................9 Flashcodes 3, 4, 6, 7, 8 and 9 may occur if components are defective or not connected up. Block 2: Flashcode 24 V operation, modified individual control on front axle ...................................................2 Block 3 (FL/CR/RL) and Block 4 (FR/CL/RR): Type of fault Flashcode No fault...............................................................................................................................1 Control unit defective .........................................................................................................2 Speed sensor signal path: ⇒ front: inadmissible gap ..................................................................................................3 ⇒ centre: inadmissible gap................................................................................................4 ⇒ rear: inadmissible gap ...................................................................................................5 ⇒ front: crack or short-circuit .............................................................................................6 ⇒ centre: crack or short-circuit ..........................................................................................7 ⇒ rear: crack or short-circuit..............................................................................................8 Undervoltage, or relay for pressure control valves cannot be triggered.............................9 Signal path for pressure control valve: ⇒ front .............................................................................................................................10 ⇒ centre...........................................................................................................................11 ⇒ rear ..............................................................................................................................12 Relay for pressure control valve cannot switch (sticking) ................................................13 Signal path for ASR solenoid valve..................................................................................14 Inadmissible configuration (incorrect solenoid valve may be fitted).................................15 SD 206-2.97 Page 7 of 62
  • 8. BOSCH ABS/ASR 2M Reading out the fault memory − Switch off ignition and connect up request button − Switch on ignition − Press button for > 1 second Blocks 1 and 2 indicate the configuration to which the control unit is set. In Blocks 3 and 4 the faults in the diagonals FL/RR (Block 3) and FR/RL (Block 4) can be read out. Duration of a flash .................................................................... approx. 0,2 s Pause between flashes ............................................................ approx. 0,4 s Pause between blocks ............................................................. approx. 1,5 s Example of flashcode: Flashcode 2 in Block 1, Flashcode 2 in Block 2, Flashcode 3 in Block 3 and Flashcode 1 in Block 4. Lamp in on request button off Block 1 Block 2 Block 3 Block 4 Erasing the fault memory − Switch off ignition and connect up request button − Press button and keep it pressed − Switch on ignition and release button after > 2 seconds ASR check lamp: Continually on: fault in servomotor path Dimmed permanent light: fault in signal at terminal W Gap recognition from control unit 81.25935-6410 onwards − Drive vehicle at speed > 20 km/h − Stop vehicle and switch off ignition − Switch on ignition ⇒ Gap in order: ABS lamp continually on. ⇒ Gap enlarged: ABS lamp flashes 3 x and then remains continually on. Adjust speed sensors and accelerate vehicle several times from standstill to > 20 km/h so that the control unit can adjust to the change in the gaps. SD 206-2.97 Page 8 of 62
  • 9. Block 1: Flashcode ABS unit with HGB (from control unit 81.25935-6410)......................................2 ABS unit with ASR engine control and HGB (not an MAN application)..................3 ABS unit with ASR brake control (not an MAN application) ...................................4 ABS unit with ASR brake and engine control and HGB ...................................5 Flashcodes 3 and 4 may occur if components are defected or not connected up. Block 2: Flashcode 24 V operation: individual control modified on front axle .......................................2 Block 3 (FL/RR) and Block 4 (FR/RL): Type of fault Flashcode No fault...................................................................................................................1 Control unit defective .............................................................................................2 Speed sensor signal path: ⇒ front: inadmissible gap or short-circuit...............................................................3 ⇒ rear: inadmissible gap or short-circuit ...............................................................4 ⇒ front: crack or short-circuit .................................................................................5 ⇒ rear: crack or short-circuit..................................................................................6 Undervoltage or relay for pressure control valve cannot be triggered ...................7 Pressure control valve signal path: ⇒ front ...................................................................................................................9 ⇒ rear ..................................................................................................................10 Relay for pressure control valve cannot switch (sticking) ....................................13 Signal path for ASR solenoid valve......................................................................14 Connection diagram for request button Bus X40 X201 X202 X202 X124 SD 206-2.97 Page 9 of 62
  • 10. BOSCH ABS/ASR 2M Stage 1 Reading out the fault memory − Switch off ignition and connect up request button − Switch on ignition − Press button for > 1 second Blocks 1 and 2 indicate the configuration to which the control unit is set. In Blocks 3 and 4 the faults in the diagonals FL/RR (Block 3) and FR/RL (Block 4) can be read out. Duration of a flash ............................................................................................ approx. 0.2 s Pause between flashes .................................................................................... approx. 0.4 s Pause between blocks ..................................................................................... approx. 1.5 s Example of flashcode: Flashcode 2 in Block 1, Flashcode 2 in Block 2, Flashcode 3 in Block 3 and Flashcode 1 in Block 4. Lamp in on request button off Block 1 Block 2 Block 3 Block 4 Erasing the fault memory − Switch off ignition and connect up request button − Press button and keep it pressed − Switch on ignition and release button after > 3 seconds Connection diagram for request button Bus X40 X201 X202 X202 SD 206-2.97 Page 10 of 62
  • 11. Block 1: Flashcode ABS unit with HGB...............................................................................................................2 ABS unit with ASR engine control and HGB (not an MAN application)..................................3 ABS unit with ASR brake control and HGB (not an MAN application) ...................................4 ABS unit with ASR brake and engine control and HGB ...................................................5 Flashcodes 3 and 4 may occur if components are defective or not connected up. Block 2: Flashcode 24 V operation: individual control modified on front axle .......................................................2 Block 3 (FL/RR) and Block 4 (FR/RL): Type of fault Flashcode No fault...................................................................................................................................1 Control unit defective .............................................................................................................2 Speed sensor signal path: ⇒ front: inadmissible gap or short-circuit...............................................................................3 ⇒ rear: inadmissible gap or short-circuit ...............................................................................4 ⇒ front: crack or short-circuit .................................................................................................6 ⇒ rear: crack or short-circuit..................................................................................................7 Undervoltage or relay for pressure control valves cannot be triggered..................................9 Pressure control valve signal path: ⇒ front .................................................................................................................................10 ⇒ rear ..................................................................................................................................11 Relay for pressure control valve cannot switch (sticking) ....................................................13 Signal path for ASR control valve ........................................................................................14 Fault in servomotor ..............................................................................................................15 Fault in C3/B7-Signal ...........................................................................................................16 Fault in signal at terminal W ................................................................................................17 Wheel equalisation difference too large...............................................................................18 Fault in signal path for relay for engine brake/retarder switch-off (emission possible only in Block 4) ......................................................................................19 Fault in signal path for clutch switch ....................................................................................20 Gap recognition − Drive vehicle at > 20 km/h − Stop vehicle and switch off ignition − Switch on ignition ⇒ Gap in order: ABS lamp is continually on. ⇒ Gap enlarged: ABS lamp flashes 3x and then remains continually on. Adjust speed sensors and accelerate vehicle several times from standstill to > 20 km/h so that the control unit can adjust to the changed gaps. SD 206-2.97 Page 11 of 62
  • 12. BOSCH ABS/ASR CI 12 Reading out the fault memory − Switch off ignition and connect up request button − Switch on ignition − Wait for 2 seconds and then press button for at least 2 seconds. The flashcodes are emitted in two blocks. Block 1 indicates the configuration to which the control unit is set. Block 2 indicates the actual fault code. Each fault code must be re- quested individually. Pause before first flash .................................................................................... approx. 3 s Duration of a flash ............................................................................................ approx. 0.5 s Pause between hundreds and tens or tens and units....................................... approx. 3 s Pause between hundreds and hundreds .......................................................... approx. 1 s Pause between tens and tens .......................................................................... approx. 1 s Pause between units and units......................................................................... approx. 1 s Example of flashcode: Flashcode 5 in Block 1, Flashcode 121 in Block 2. Lamp in on request button off Erasing the fault memory Block 1 Block 2 − Switch off ignition and con- nect up request button − Press the button − Switch on ignition and keep button pressed for > 2 seconds − Do not switch off ignition until at least 5 seconds have passed. Connection diagram for request button X202 SD 206-2.97 Page 12 of 62
  • 13. Block 1: Flashcode Pure ABS unit, modified individual control on front axle.................................................2 ABS unit with ASR engine control (not an MAN application) .................................................3 ABS unit with ASR brake control (not an MAN application) ...................................................4 ABS unit with ASR brake and engine control....................................................................5 Pure ABS unit with Select-Low control on front axle (not an MAN application)........................................................................................................6 ABS unit with Select-Low control on front axle and ASR engine control (not an MAN application)........................................................................7 ABS unit with Select-Low control on front axle and ASR brake control (not an MAN application) .........................................................................8 ABS unit with Select-Low control on front axle and ASR brake and engine control (not an MAN application).......................................................9 Flashcodes 3, 4, 6, 7, 8 and 9 may occur if components are defective or not connected up. Block 2: Type of fault Flashcode No fault...............................................................................................................................121 CAN data bus: ⇒ BusOff, repair CAN bus .................................................................................................211 ⇒ Tachograph signal, plausibility ......................................................................................212 ⇒ Communication interrupted, repair CAN bus.................................................................213 ⇒ Time-out, gearbox messages, repair CAN bus .............................................................214 ⇒ Time-out, engine messages, repair CAN bus................................................................215 ⇒ Time-out, retarder messages, repair CAN bus..............................................................216 Brake light switch not yet actuated, check cabling.............................................................217 Control unit defective .........................................................................................................221 Control unit defective .........................................................................................................222 Control unit defective .........................................................................................................223 Control unit defective .........................................................................................................224 Control unit defective .........................................................................................................225 Control unit defective .........................................................................................................226 Control unit defective .........................................................................................................227 Configuration EEPROM parameters defective...................................................................228 Axle tyres or pulse ring incorrect........................................................................................232 Voltage supply to pressure control valve, undervoltage.....................................................242 Voltage supply to pressure control valve, interruption .......................................................243 Control unit defective .........................................................................................................244 Pressure control valve: ⇒ Earth, FR or RL, control unit output, short-circuit to earth .............................................251 ⇒ Earth, FR or RL, control unit output, short-circuit to +UBatt ..........................................252 ⇒ Earth, diagonal FR/RL, interruption (PIN X1, 12) ..........................................................253 ⇒ Voltage supply, diagonal FR/RL, incorrect polarity of +/-..............................................254 ⇒ Earth, FL or RR, control unit output, short-circuit to earth .............................................255 ⇒ Earth, FL or RR, control unit output, short-circuit to +UBatt ..........................................256 SD 206-2.97 Page 13 of 62
  • 14. Pressure control valve: ⇒ Earth, diagonal FL/RR, interruption (PIN X1, 11) ..........................................................257 ⇒ Voltage supply, diagonal FL/RR, incorrect polarity of +/-..............................................258 Speed sensors: ⇒ RL, interruption/short-circuit ..........................................................................................312 ⇒ RL, pulse ring defective, gap too large..........................................................................316 ⇒ FL, interruption/short-circuit...........................................................................................322 ⇒ FL, pulse ring defective, gap too large ..........................................................................326 ⇒ RR, interruption/short-circuit..........................................................................................342 ⇒ RR, pulse ring defective, gap too large .........................................................................346 ⇒ FR, interruption/short-circuit ..........................................................................................362 ⇒ FR, pulse ring defective, gap too large..........................................................................366 ⇒ RL, interturn fault, gap, pole wheel, signal ....................................................................411 ⇒ RL, tyres or pulse ring incorrect ....................................................................................415 ⇒ FL, interturn fault, gap, pole wheel, signal.....................................................................421 ⇒ FL, tyres or pulse ring incorrect.....................................................................................425 Speed sensors: ⇒ RR, interturn fault, gap, pole wheel, signal....................................................................441 ⇒ RR, tyres or pulse ring incorrect....................................................................................445 ⇒ FR, interturn fault, gap, pole wheel, signal ....................................................................461 ⇒ FR, tyres or pulse ring incorrect ....................................................................................465 Pressure control valve: ⇒ FL, inlet valve, interruption ............................................................................................512 ⇒ FL, inlet valve, short-circuit to earth ..............................................................................513 ⇒ FL, inlet valve, short-circuit to +UBatt ...........................................................................514 ⇒ FL, earth connection, interruption..................................................................................515 ⇒ FL, outlet valve, interruption ..........................................................................................516 ⇒ FL, outlet valve, short-circuit to earth ............................................................................517 ⇒ FL, outlet valve, short-circuit to +UBatt .........................................................................518 ⇒ RL, inlet valve, interruption............................................................................................522 ⇒ RL, inlet valve, short-circuit to earth ..............................................................................523 ⇒ RL, inlet valve, short-circuit to +UBatt ...........................................................................524 ⇒ RL, earth connection, interruption..................................................................................525 ⇒ RL, outlet valve, interruption..........................................................................................526 ⇒ RL, outlet valve, short-circuit to earth............................................................................527 ⇒ RL, outlet valve, short-circuit to +UBatt.........................................................................528 ⇒ RR, inlet valve, interruption ...........................................................................................532 ⇒ RR, inlet valve, short-circuit to earth .............................................................................533 ⇒ RR, inlet valve, short-circuit to +UBatt ..........................................................................534 ⇒ RR, earth connection, interruption.................................................................................535 ⇒ RR, outlet valve, interruption .........................................................................................536 ⇒ RR, outlet valve, short-circuit to earth ...........................................................................537 ⇒ RR, outlet valve, short-circuit to +UBatt ........................................................................538 ⇒ FR, inlet valve, interruption............................................................................................552 SD 206-2.97 Page 14 of 62
  • 15. Block 2: Type of fault Flashcode Pressure control valve: ⇒ FR, inlet valve, short-circuit to earth..............................................................................553 ⇒ FR, inlet valve, short-circuit to +UBatt...........................................................................554 ⇒ FR, earth connection, interruption .................................................................................555 ⇒ FR, outlet valve, interruption .........................................................................................556 ⇒ FR, outlet valve, short-circuit to earth............................................................................557 ⇒ FR, outlet valve, short-circuit to +UBatt.........................................................................558 ⇒ FL, short-circuit to another valve ...................................................................................611 ⇒ FL, incorrectly configured ..............................................................................................616 ⇒ RL, short-circuit to another valve...................................................................................621 ⇒ RR, short-circuit to another valve ..................................................................................631 ⇒ FR, short-circuit to another valve...................................................................................651 ⇒ FR, incorrectly configured .............................................................................................656 ASR solenoid valve: ⇒ Interruption ....................................................................................................................712 ⇒ Short-circuit to earth ......................................................................................................713 ⇒ Short-circuit to +UBatt ...................................................................................................714 ⇒ Short-circuit to another valve.........................................................................................721 ⇒ Recognised but not configured......................................................................................726 Interaxle lock/shut-off valve, short-circuit to earth..............................................................811 Interaxle lock/shut-off valve, short-circuit to +UBatt ...........................................................812 Engine interface: ⇒ DKR, short-circuit to earth or +UBatt.............................................................................813 ⇒ DKV, actuator reports fault ............................................................................................814 ⇒ DKV, interruption/short-circuit........................................................................................815 ⇒ DKV, time-out ................................................................................................................816 Triggering of relay for engine brake/retarder: ⇒ Short-circuit to +UBatt ...................................................................................................817 ⇒ Interruption or short-circuit to earth ...............................................................................818 SD 206-2.97 Page 15 of 62
  • 16. KNORR ABS Reading out the fault memory − Switch off ignition and connect up request button − Switch on ignition and wait for 2 seconds − Press button for 2 seconds The first block indicates the configuration to which the control unit is set. The second block indicates the fault codes. Each fault code must be requested individually. Duration of a ten............................................................................................... approx. 2 s Duration of a unit .............................................................................................. approx. 0.5 s Pause between tens and units ......................................................................... approx. 3 s Pause between units and units......................................................................... approx. 1 s Pause between tens and tens .......................................................................... approx. 1 s Example of flashcode: Flashcode 2 in Block 1 and Flashcode 12 in Block 2. Lamp in on request button off Block 1 Block 2 Erasing the fault memory − Switch of ignition and connect up request button − Press button and keep it pressed − Switch on ignition and release it after > 2 seconds Connection diagram for request button X124 X201 X202 X202 SD 206-2.97 Page 16 of 62
  • 17. Block 1: Flashcode ABS unit without ASR..........................................................................................................2 ABS unit with ASR engine control (not an MAN application) .................................................3 ABS unit with ASR brake control (not an MAN application) ...................................................4 ABS unit with ASR brake and engine control (not an MAN application) ................................5 Flashcodes 3, 4 and 5 may occur if components are defective or not connected up. Block 2 (Diagonal 1 FR/RL, Diagonal 2 FL/RR): Type of fault Flashcode No fault...................................................................................................................................1 Speed sensors: ⇒ FL, interruption or short-circuit.........................................................................................10 ⇒ FL, gap too large, interturn fault, pole wheel fault ...........................................................11 ⇒ FR, interruption or short-circuit ........................................................................................12 ⇒ FR, gap too large, interturn fault, pole wheel fault...........................................................13 ⇒ RL, interruption or short-circuit ........................................................................................14 ⇒ RL, gap too large, interturn fault, pole wheel fault...........................................................15 ⇒ RR, interruption or short-circuit........................................................................................16 ⇒ RR, gap too large, interturn fault, pole wheel fault...........................................................17 Pressure control valve: ⇒ FL, interruption or short-circuit.........................................................................................22 ⇒ FR, interruption or short-circuit ........................................................................................23 ⇒ RL, interruption or short-circuit ........................................................................................24 ⇒ RR, interruption or short-circuit........................................................................................25 ASR brake valve, RL, interruption or short-circuit ................................................................28 ASR brake valve, RR, interruption or short-circuit ...............................................................29 ASR engine control, E-Gas/EDC interface fault...................................................................31 Relay voltage supply for pressure control valve: ⇒ Diagonal 1 cannot be switched off (contact sticking).......................................................32 ⇒ Diagonal 1 cannot be switched off...................................................................................33 ⇒ Diagonal 2 cannot be switched off (contact sticking).......................................................34 ⇒ Diagonal 2 cannot be switched off...................................................................................35 ABS engine brake/retarder switch-off, interruption or short-circuit.......................................36 ABS warning lamp, tractor, interruption or short-circuit........................................................38 Switch-on time monitoring of valves (implausible triggering)...............................................52 ASR recognised but not configured......................................................................................53 Differences in wheel diameter too large...............................................................................54 Voltage supply for pressure-control valves, diagonal 1, overvoltage...................................56 Voltage supply for pressure-control valves, diagonal 2, overvoltage...................................57 Speed recording, signals with frequency > 1500 Hz, unwanted signals ..............................91 Pressure control valves, bleeding and holding times too long .............................................92 Configuration error (defective EEPROM parameters)..........................................................98 Control unit defective ...........................................................................................................99 SD 206-2.97 Page 17 of 62
  • 18. WABCO „C“ ABS/ASR Reading out the fault memory − Switch-off ignition and connect up request switch − Switch on ignition and wait for 2 seconds − Close the switch If the switch is opened the fault entry in the fault memory will be erased. Switching off the ignition before the switch is opened ends the flashcode emission without erasing the fault in the fault memory. The first block is a "starting block"; this begins the fault code emission. The second block indicates the configuration to which the control unit is set. Blocks 3 and 4 indicate the actual fault codes. The flashcode emission may be deactivated (ended) only in the pauses between the constantly repeated flashcodes. Duration of starting block ................................................................................. approx. 2.5 s Pause between blocks ..................................................................................... approx. 2.5 s Duration of a flash ............................................................................................ approx. 0.5 s Pause between flashes .................................................................................... approx. 0,5 s Example of flashcode: Starting block (Block1), Flashcode 2 in Block 2, Flashcode 6 in Block 3 and Flashcode 6 in Block 4. Lamp in on request switch off Block 1 Block 2 Block 3 Block 4 Erasing the fault memory − Switch off ignition and connect up request switch − Switch on ignition and wait for 2 seconds − Close the switch − Open the switch during flashcode emission. Connection diagram for request switch X202 SD 206-2.97 Page 18 of 62
  • 19. Block 2: Flashcode ABS system 6S/6K.................................................................................................................1 ABS system 4S/4K.................................................................................................................2 ABS system 4S/3K.................................................................................................................3 ABS system 6S/4K.................................................................................................................4 ABS system 6S/3K.................................................................................................................5 Flashcodes 3, 4 and 5 may occur if parts are defective or not connected up. Block 3 and Block 4: Type of fault Flashcode Block 3 Block 4 Valve relay FR/RL, undervoltage ...........................................................................6 .............6 Valve relay FL/RR, undervoltage ...........................................................................6 .............7 Speed sensor: ⇒ FR, wheel speed signal fault (failure) ................................................................6 .............8 ⇒ FL, wheel speed signal fault (failure).................................................................6 .............9 ⇒ FR, interruption or short-circuit in cable ............................................................6 ...........10 ⇒ FL, interruption or short-circuit in cable .............................................................6 ...........11 ⇒ FR, wheel speed signal implausible..................................................................6 ...........12 ⇒ FL, wheel speed signal implausible ..................................................................6 ...........13 ⇒ RL, wheel speed signal fault (failure) ................................................................7 .............0 ⇒ RR, wheel speed signal fault (failure)................................................................7 .............1 ⇒ RL, interruption of short-circuit in cable.............................................................7 .............2 ⇒ RR, interruption or short-circuit in cable ............................................................7 .............3 ⇒ RL, wheel speed signal implausible ..................................................................7 .............4 ⇒ RR, wheel speed signal implausible .................................................................7 .............5 ⇒ ML, wheel speed signal fault (failure)................................................................7 .............8 ⇒ MR, wheel speed signal fault (failure) ...............................................................7 .............9 ⇒ ML, inadmissible impedance, interruption/short-circuit .....................................7 ...........10 ⇒ MR, interruption or short-circuit in cable............................................................7 ...........11 ⇒ ML, wheel speed signal implausible..................................................................7 ...........12 ⇒ MR, wheel speed signal implausible .................................................................7 ...........13 Control unit defective .............................................................................................8 .............0 Control unit defective .............................................................................................8 .............1 ASR proportional valve (not an MAN application)..................................................8 .............2 ASR interface, DKR signal, interruption in cable (PIN 29) .....................................8 .............3 ASR proportional valve (not an MAN application)..................................................8 .............4 ASR interface, DKV signal, faulty data transfer (PIN 28) .......................................8 .............5 Interface for V signal (not an MAN application)......................................................8 .............6 ASR interface, DKV signal, interruption in cable (PIN 28) .....................................8 .............7 ASR interface, DKV signal, faulty data transfer (PIN 28) .......................................8 .............9 SD 206-2.97 Page 19 of 62
  • 20. Type of fault Flashcode Block 3 Block 4 Pressure control valve: ⇒ FR, inlet, short-circuit to earth ...........................................................................8 ...........10 ⇒ FL, inlet, short-circuit to earth............................................................................8 ...........11 ⇒ FR, inlet, interruption in cable............................................................................8 ...........12 ⇒ FL, inlet, interruption in cable ............................................................................8 ...........13 ⇒ FR, outlet, short-circuit to earth .........................................................................8 ...........14 ⇒ FL, outlet, short-circuit to earth..........................................................................8 ...........15 ⇒ FR, outlet, interruption in cable .........................................................................9 .............0 ⇒ FL, outlet, interruption in cable ..........................................................................9 .............1 ⇒ RL, inlet, short-circuit to earth ...........................................................................9 .............2 ⇒ RR, inlet, short-circuit to earth...........................................................................9 .............3 ⇒ RL, inlet, interruption in cable............................................................................9 .............4 ⇒ RR, inlet, interruption in cable ...........................................................................9 .............5 ⇒ RL, outlet, short-circuit to earth .........................................................................9 .............6 ⇒ RR, outlet, short-circuit to earth.........................................................................9 .............7 ⇒ RL, outlet, interruption in cable..........................................................................9 .............8 ⇒ RR, outlet, interruption in cable .........................................................................9 .............9 ⇒ ML, inlet, short-circuit to earth ...........................................................................9 ...........10 ⇒ MR, inlet, short-circuit to earth ..........................................................................9 ...........11 ⇒ ML, inlet, interruption in cable ...........................................................................9 ...........12 ⇒ MR, inlet, interruption in cable...........................................................................9 ...........13 ⇒ ML, outlet, short-circuit to earth.........................................................................9 ...........14 ⇒ MR, outlet, short-circuit to earth ........................................................................9 ...........15 ⇒ ML, outlet, interruption in cable .......................................................................10 .............0 ⇒ MR, outlet, interruption in cable.......................................................................10 .............1 ASR valve RL, short-circuit to earth .....................................................................10 .............2 ASR valve RR, short-circuit to earth ....................................................................10 .............3 ASR valve RL, interruption in cable .....................................................................10 .............4 ASR valve RR, interruption in cable.....................................................................10 .............5 Retarder shut-off relay (PIN 11), short-circuit to +UBatt ......................................10 .............7 ASR engine control: inadmissible drive slip (EMS/EDC) .....................................10 .............8 ASR engine control: inadmissible drive slip (EMS/EDC) .....................................10 .............9 Pressure control valve: ⇒ FR, short-circuit to +UBatt or output stage defective.......................................11 ...........12 ⇒ FL, short-circuit to +UBatt or output stage defective .......................................11 ...........13 ⇒ RL, short-circuit to +UBatt or output stage defective.......................................11 ...........14 ⇒ RR, short-circuit to +UBatt or output stage defective ......................................11 ...........15 ⇒ ML, short-circuit to +UBatt or output stage defective ......................................12 .............0 ⇒ MR, short-circuit to +UBatt or output stage defective......................................12 .............1 ASR valve RL, short-circuit to +UBatt or output stage defective..........................12 .............2 ASR valve RR, short-circuit to +UBatt or output stage defective .........................12 .............3 ASR proportional valve (not an MAN application)................................................12 .............4 Retarder shut-off relay (PIN 11), short-circuit to earth .........................................12 .............7 SD 206-2.97 Page 20 of 62
  • 21. Type of fault Flashcode Block 3 Block 4 Pressure control valve: ⇒ FR, short-circuit to +UBatt ...............................................................................12 .............8 ⇒ FL, short-circuit to +UBatt................................................................................12 .............9 ⇒ RL, short-circuit to +UBatt ...............................................................................12 ...........10 ⇒ RR, short-circuit to +UBatt...............................................................................12 ...........11 ⇒ ML, short-circuit to +UBatt...............................................................................12 ...........12 ⇒ MR, short-circuit to +UBatt ..............................................................................12 ...........13 ASR valve RL, short-circuit to +UBatt ..................................................................12 ...........14 ASR valve RR, short-circuit to +UBatt .................................................................12 ...........15 ASR proportional valve (not an MAN application)................................................13 .............0 Valve relay RL/FR, relay contact sticking ............................................................13 .............4 Valve relay RR/FL, relay contact sticking ............................................................13 .............5 Control unit defective ...........................................................................................13 .............6 Control unit overvoltage, check alternator charge voltage ...................................13 .............7 Control unit defective ...........................................................................................13 .............8 Control unit defective ...........................................................................................13 .............9 Control unit defective ...........................................................................................13 ...........10 Control unit defective ...........................................................................................13 ...........11 Control unit defective ...........................................................................................13 ...........12 Control unit defective ...........................................................................................13 ...........13 Control unit defective ...........................................................................................13 ...........14 Control unit defective ...........................................................................................13 ...........15 Control unit defective ...........................................................................................14 .............0 Control unit defective ...........................................................................................14 .............1 Control unit defective ...........................................................................................14 .............2 Control unit defective ...........................................................................................14 .............3 Control unit defective ...........................................................................................14 .............4 Control unit defective ...........................................................................................14 .............5 Pressure control valve modulation RL/FR, switch-on time too long.....................14 .............6 Pressure control valve modulation RR/FL, switch-on time too long.....................14 .............7 ASR valve RL, switch-on time too long ................................................................14 .............8 ASR-valve RR, switch-on time too long ...............................................................14 .............9 Control unit defective ...........................................................................................14 ...........10 Control unit defective ...........................................................................................14 ...........11 Control unit defective ...........................................................................................14 ...........12 Control unit defective ...........................................................................................14 ...........13 Control unit defective ...........................................................................................14 ...........14 Control unit defective ...........................................................................................14 ...........15 SD 206-2.97 Page 21 of 62
  • 22. ECAS air suspension for buses Reading out the fault memory − Switch off ignition and connect up request button − Switch on ignition − Wait for > 2 seconds and press button Emission of the flashcode begins after 3 seconds. When the first flashcode has been emit- ted further emission is automatically interrupted. For the next fault the button be pressed again for at least 2 seconds. Duration of a unit .............................................................................................. approx. 0.5 s Duration of a ten............................................................................................... approx. 2 s Pause between a ten and a unit ....................................................................... approx. 3 s Pause between a unit and a unit ...................................................................... approx. 1 s Pause between a ten and a ten........................................................................ approx. 1 s Example of flashcode: fault code 12 Lamp in on request button off Erasing the fault memory − Switch off ignition and connect up request button − Press button and keep it pressed − Switch on ignition and release button after > 2 seconds In vehicles with 2 ECAS control units (articulated buses) each control unit must be read and/or erased separately. For this the 35-pole plug on the control unit not affected must be pulled out when the ignition is switched off. Connection diagram for request button X201 X203 X203 SD 206-2.97 Page 22 of 62
  • 23. Type of fault Flashcode Internal fault in control unit: ⇒ Control unit defective.........................................................................................................1 ⇒ Cumulative test fault in calibration data, recalibrate displacement sensors......................2 ⇒ Control unit defective.........................................................................................................3 ⇒ Control unit defective.........................................................................................................4 ⇒ Control unit defective.........................................................................................................5 ⇒ Control unit defective.........................................................................................................6 ⇒ Cumulative test fault in calibration data, recalibrate pressure sensor ............................ (8) ⇒ Control unit or ECAS fuse, terminal 30, defective .............................................................9 Sensor fault, interruption or short-circuit to +UB: ⇒ Displacement sensor rear [front] right .............................................................................10 ⇒ Displacement sensor rear [front] left ...............................................................................11 ⇒ Displacement sensor front [centre]..................................................................................12 Pressure sensor, short-circuit to +UB ............................................................................... (15) Anti-trap device contact strip, interruption or short-circuit to +UB..................................... (17) Sensor fault, interruption or short-circuit to earth: ⇒ Displacement sensor rear [front] right .............................................................................20 ⇒ Displacement sensor rear [front] left ...............................................................................21 ⇒ Displacement sensor front [centre]..................................................................................22 Pressure sensor, short-circuit or interruption to earth ....................................................... (25) Anti-trap device contact strip, short-circuit to earth ........................................................... (27) Fault in solenoid valve, interruption or short-circuit to +UB: ⇒ Central solenoid valve, reservoir A * ...............................................................................30 ⇒ Valve RA [FA] left C * ......................................................................................................31 ⇒ Valve RA [FA] right B * ....................................................................................................32 ⇒ Valve FA [CA] left F * ......................................................................................................33 ⇒ Valve FA [CA] right E * ....................................................................................................34 ⇒ Bus-stop brake valve.................................................................................................... (35) ⇒ Valve for primary current throttle .................................................................................. (39) ⇒ Valve, transverse throttle D *........................................................................................ (70) Solenoid valve fault, interruption or short-circuit to earth: ⇒ Central solenoid valve, reservoir A * ...............................................................................40 ⇒ Valve RA [FA] left C * ......................................................................................................41 ⇒ Valve RA [FA] right B * ....................................................................................................42 ⇒ Valve FA [CA] left F * ......................................................................................................43 ⇒ Valve FA [CA] right E * ....................................................................................................44 ⇒ Bus-stop brake valve.................................................................................................... (45) ⇒ Valve, primary current throttle ...................................................................................... (49) ⇒ Valve, transverse throttle D *........................................................................................ (71) [ ] For the forebody of articulated buses the data in the square brackets apply. ( ) For vehicles with this equipment. * The letter is on the corrugated tube of the relevant valve. SD 206-2.97 Page 23 of 62
  • 24. Type of fault Flashcode Relay, door release: ⇒ Interruption or short-circuit to +UB ............................................................................... (36) ⇒ Short-circuit to earth ..................................................................................................... (46) Plausibility fault (mechanical fault) during raising: ⇒ Displacement sensor rear [front] right .............................................................................50 ⇒ Displacement sensor rear [front] left ...............................................................................51 ⇒ Displacement sensor front [centre]..................................................................................52 Plausibility fault (mechanical fault) during lowering: ⇒ Displacement sensor rear [front] right .............................................................................60 ⇒ Displacement sensor rear [front] left ...............................................................................61 ⇒ Displacement sensor front [centre]..................................................................................62 Control unit defective ...........................................................................................................80 Speed signal interruption or short-circuit to +UB .................................................................81 [] For the forebodies of articulated buses the data in square brackets apply. () For vehicles with this equipment. * The letter is on the corrugated tube of the relevant valve. SD 206-2.97 Page 24 of 62
  • 25. Door control system IFE Reading out the fault memory − Switch off ignition and connect up request button − Switch on ignition − Press button for > 2 seconds Duration of a ten............................................................................................... approx. 2 s Duration of a unit .............................................................................................. approx. 0.5 s Pause between a ten and a unit ....................................................................... approx. 3 s Pause between a unit and a unit ...................................................................... approx. 1 s Example of flashcode: Fault code 11 Lamp in on request button off Erasing the fault memory − Switch off ignition and connect up request button − Press button and keep it pressed − Switch on ignition and release button after > 2 seconds Type of fault Flashcode Break in connecting cable from door motor ...........................................................................1 Inward-swinging door: more than 10 seconds to reach fully open position.......................... *2 Slide-glide door: limit switch reports door closed, door displacement sensor report displacement pulses ...................................................................................... *2 Door does not unlock within 3 seconds..................................................................................3 Inward-swinging door: more than 10 seconds to reach fully closed position ....................... *4 Slide-glide door: fault in door displacement sensor ............................................................. *4 Door monitoring in opening direction responded 3x during opening ......................................5 Motor current monitor responded at 5 closing procedures in succession ..............................6 Short-circuit at one output of door control system..................................................................7 Fault in pressure wave switch (responded continuously for more than 1 minute)..................8 Fault in electronic eye (responded continuously for more than 1 minute) ..............................9 Fault in door opening button (actuated continuously for more than 1 minute)......................10 Fault in driver’s button (actuated continuously for more than 1 minute) ...............................11 * Slide-glide door and inward-swinging door have the same fault code number Flashcodes 1, 2, 3 and 4 lead to switch-off of door motor. SD 206-2.97 Page 25 of 62
  • 26. ECAS air suspension for trucks Reading out the fault memory − Switch off ignition and connect up request button − Switch on ignition − Press button for > 2 seconds Emission of the flashcode begins after 3 seconds. After emission of the first fault further emission is automatically interrupted. For the next fault the button must be pressed again for at least 2 seconds. Duration of a unit .............................................................................................. approx. 0.5 s Duration of a ten............................................................................................... approx. 2 s Pause between a ten and a unit ....................................................................... approx. 3 s Pause between a unit and a unit ...................................................................... approx. 1 s Pause between a ten and a ten........................................................................ approx. 1 s Example of flashcode: Fault code 12 Lamp in on request button off Erasing the fault memory − Switch off ignition and connect up request button − Press button and keep it pressed − Switch on ignition and release button after at least 2 and at most 4 seconds Connection diagram for request button X201 X203 X203 SD 206-2.97 Page 26 of 62
  • 27. 4x2 6x2 Type of fault Flashcode Control unit defective ....................................................................................................1 ............. 1 Cumulative test fault in calibration data (recalibrate displacement sensors)...................2 ............. 2 Control unit defective.......................................................................................................3 ............. 3 Control unit defective.......................................................................................................4 ............. 4 Control unit defective.......................................................................................................5 ............. 5 Control unit defective.......................................................................................................6 ............. 6 Control unit defective....................................................................................................... - ............ *7 Pressure switch, moving-off aid/empty run ...................................................................... - ............. 8 Control unit or ECAS fuse, terminal 30 defective ............................................................ - ............. 9 Sensor fault, interruption or short-circuit to +UB: ⇒ Displacement sensor RR ..........................................................................................10 ........... 10 ⇒ Displacement sensor RL...........................................................................................11 ........... 11 ⇒ Displacement sensor, front .......................................................................................12 ........... 12 Sensor fault, short-circuit to earth: ⇒ Displacement sensor RR ..........................................................................................14 ........... 20 ⇒ Displacement sensor RL...........................................................................................15 ........... 21 ⇒ Displacement sensor, front .......................................................................................16 ........... 22 Valve fault, interruption or short-circuit to +UB: ⇒ Central solenoid valve, reservoir ..............................................................................20 ........... 30 ⇒ Solenoid valve, RA or drive axle left.........................................................................21 ........... 31 ⇒ Solenoid valve, RA or drive axle right ......................................................................22 ........... 32 ⇒ Solenoid valve, lowering/burdening lifting/trailing axle.............................................. -- ........... 33 ⇒ Solenoid valve, raising/relieving lifting/trailing axle ................................................... -- ........... 34 ⇒ Solenoid valve, front axle .........................................................................................23 ........... 36 ⇒ ALB control ...............................................................................................................24 ........... 35 ⇒ Solenoid valve, lifting bellows.................................................................................... -- ........... 37 Valve fault, interruption or short-circuit to earth: ⇒ Central solenoid valve, reservoir ..............................................................................30 ........... 40 ⇒ Solenoid valve, RA or drive axle left.........................................................................31 ........... 41 ⇒ Solenoid valve, RA or drive axle right ......................................................................32 ........... 42 ⇒ Solenoid valve, lowering/burdening lifting/trailing axle.............................................. -- ........... 43 ⇒ Solenoid valve, raising/relieving lifting/trailing axle ................................................... -- ........... 44 ⇒ Solenoid valve, front axle .........................................................................................33 ........... 46 ⇒ Solenoid valve, lifting bellows.................................................................................... -- ........... 47 Plausibility fault (mechanical fault) during raising: ⇒ Displacement sensor, RR .........................................................................................40 ........... 50 ⇒ Displacement sensor, RL..........................................................................................41 ........... 51 ⇒ Displacement sensor, front .......................................................................................42 ........... 52 Plausibility fault (mechanical fault) during lowering: ⇒ Displacement sensor, RR .........................................................................................44 ........... 60 ⇒ Displacement sensor, RL..........................................................................................45 ........... 61 ⇒ Displacement sensor, front .......................................................................................46 ........... 62 Control unit defective...................................................................................................... -- .........**80 Speed signals interrupted or short-circuit to +UB........................................................... -- .........**81 * = up to control unit: 81.25935-6416; 466 055 041 0 ** = from control unit 81.25935-6547; 466 055 047 0 SD 206-2.97 Page 27 of 62
  • 28. EFR running-gear control for trucks Reading out the fault memory − Switch off ignition and connect up request button − Switch on ignition − Press button for > seconds Emission of the flashcode begins after 3 seconds. After emission of the first fault further emission in automatically interrupted. For the next fault the button must be pressed again for at least 2 seconds. Duration of a unit .............................................................................................. approx. 0.5 s Duration of a ten............................................................................................... approx. 2 s Pause between a ten and a unit ....................................................................... approx. 3 s Pause between a unit and a unit ...................................................................... approx. 1 s Pause between a ten and a ten........................................................................ approx. 1 s Example of flashcode: Fault code 12 Lamp in on request button off Erasing the fault memory − Switch off ignition and connect up request button − Press button and keep it pressed − Switch on ignition and release button after at least 2 and at most 4 seconds. Connection diagram for request button X203 SD 206-2.97 Page 28 of 62
  • 29. Electronics, 4x2, 6x2 Type of fault Flashcode Control unit defective .............................................................................................................1 Cumulative test error in calibration data, recalibrate displacement sensors..........................2 Control unit defective .............................................................................................................3 Control unit defective .............................................................................................................4 Control unit defective .............................................................................................................5 Control unit defective .............................................................................................................6 Cumulative test error in calibration data, recalibrate pressure sensors .................................8 Valve relay or ECAS fuse, terminal 30, defective ..................................................................9 Sensor fault, interruption or short-circuit to +UB: ⇒ Displacement sensor RR.................................................................................................10 ⇒ Displacement sensor RL .................................................................................................11 ⇒ Displacement sensor, front..............................................................................................12 Sensor fault, short-circuit to +UB: ⇒ Pressure sensor, drive axle right .....................................................................................13 ⇒ Pressure sensor RA or drive axle left..............................................................................14 ⇒ Pressure sensor, brake ...................................................................................................15 Sensor fault, short-circuit to earth: ⇒ Displacement sensor RR.................................................................................................20 ⇒ Displacement sensor RL .................................................................................................21 ⇒ Displacement sensor, front..............................................................................................22 Sensor fault, interruption or short-circuit to earth: ⇒ Pressure sensor, RA or drive axle right...........................................................................23 ⇒ Pressure sensor, RA or drive axle left.............................................................................24 ⇒ Pressure sensor, brake ...................................................................................................25 Valve fault, interruption or short-circuit to +UB: ⇒ Central solenoid valve, reservoir.....................................................................................30 ⇒ Solenoid valve, RA or drive axle left ...............................................................................31 ⇒ Solenoid valve, RA or drive axle right .............................................................................32 ⇒ Solenoid valve, lowering/burdening lifting/trailing axle....................................................33 ⇒ Solenoid valve, raising/relieving lifting/trailing axle.........................................................34 ⇒ ALB control ......................................................................................................................35 ⇒ Solenoid valve, front axle ................................................................................................36 ⇒ Solenoid valve, dampers soft ..........................................................................................37 ⇒ Solenoid valve, dampers medium ...................................................................................38 SD 206-2.97 Page 29 of 62
  • 30. Electronics 4x2, 6x2 Type of fault Flashcode Valve fault, interruption or short-circuit to earth: ⇒ Central solenoid valve, reservoir.....................................................................................40 ⇒ Solenoid valve, RA or drive axle left ...............................................................................41 ⇒ Solenoid valve, RA or drive axle right .............................................................................42 ⇒ Solenoid valve, lowering/burdening lifting/trailing axle....................................................43 ⇒ Solenoid valve, raising/relieving lifting/trailing axle.........................................................44 ⇒ ALB control ......................................................................................................................45 ⇒ Solenoid valve, front axle ................................................................................................46 ⇒ Solenoid valve, dampers soft ..........................................................................................47 ⇒ Solenoid valve, dampers medium ...................................................................................48 Plausibility fault (mechanical fault) during raising: ⇒ Displacement sensor RR.................................................................................................50 ⇒ Displacement sensor RL .................................................................................................51 ⇒ Displacement sensor, front..............................................................................................52 Plausibility fault (mechanical fault) during lowering: ⇒ Displacement sensor RR.................................................................................................60 ⇒ Displacement sensor RL .................................................................................................61 ⇒ Displacement sensor, front..............................................................................................62 Control unit defective ...........................................................................................................80 Speed signals, interruption or short-circuit to +UB...............................................................81 SD 206-2.97 Page 30 of 62
  • 31. WEBASTO auxiliary heater Airtop 2000 Reading out the fault memory − The fault is shown automatically in the display when it occurs. The faults are shown in the display of the control box. Only one fault can be displayed. If more than one fault is present, the next fault will not be shown in the display until after the first fault has been rectified. Erasing the fault memory − After repairs switch off the heater, wait for after-running and switch heater on again. The fault will be erased automatically. Type of fault Flashcode No start, after 2 attempts to start...................................................................................... F 01 Flame interrupted, more than 5x within one heating cycle ............................................... F 02 Under/overvoltage............................................................................................................ F 03 Premature flame recognition ............................................................................................ F 04 Flame monitor, interruption or short-circuit ...................................................................... F 05 Temperature sensor for heater, interruption or short-circuit............................................. F 06 Metering pump, short-circuit............................................................................................. F 07 Blower motor, interruption/short-circuit or defective speed .............................................. F 08 Glow plug, interruption or short-circuit ............................................................................. F 09 Overheating...................................................................................................................... F 10 SD 206-2.97 Page 31 of 62
  • 32. Eberspächer auxiliary heater D1LCC/D3LCC Reading out the fault memory − Switch off the auxiliary heater − Switch on auxiliary heater with button . − Press button and with 2 seconds also press button . The last fault to occur will be shown in the display, e.g.: AF:64 With buttons and a further four faults, if present, can be read out. E.g.: F:10, F:13. Erasing the fault memory − Switch off the auxiliary heater- − Switch on auxiliary heater with button . − Press button and within 2 seconds also press button . − Open the 1-pole plug connection X 683, which is at the plug connection between wiring harness and control box. − Press buttons and simultaneously and close plug connection X 683. Type of fault Fault code No fault present............................................................................................................... (0)00 Control unit, chamber 1, to relay for fresh-air blower, short-circuit to earth or control unit defective...................................................................................... (0)04 Control unit, chamber 2, to relay for electrical isolator switch or input for anti-theft system, short-circuit to earth or control unit defective ...................................... (0)05 TRS switch-off due to signal change from plus to minus at control unit, chamber 10, or plus at control unit, chamber 12 ............................................................. (0)09 Voltage between control unit chamber 5 and chamber 11: ⇒ Overvoltage > 31.8 V (30.4 V if glow plug switched on)............................................. (0)10 ⇒ Undervoltage < 21 V (19 V if glow plug switched on)................................................. (0)11 Connection between control unit and overheating sensor: no continuity......................... (0)12 Overtemperature in flame sensor > 340° C or > 2270 Ω ............................................... (0)13 To many overheatings, control unit locked...................................................................... (0)15 Check glow plug (approx. 1 Ω to 2 Ω), control units chambers 6 and 9 to glow plug, interruption or control unit defective........................................................... (0)20 Glow plug or control unit, chamber 6, to glow plug: short-circuit or control unit defective ................................................................................................... (0)21 If the fault code is read out with an Eberspächer diagnosis unit, it has 3 digits (e.g. 021). If it is read out with the module clock, it has only 2 digits (e.g. 21). SD 206-2.97 Page 32 of 62
  • 33. Type of fault Fault code Control unit, chamber 4, to connection plug for module clock: short-circuit to plus .......................................................................................................... (0)25 Burner motor or speed control defective: speed discrepancy ......................................... (0)33 Metering pump or control unit, chamber 3, to metering pump: ⇒ Short-circuit ................................................................................................................ (0)47 ⇒ No continuity, check minus supply for metering pump ............................................... (0)48 Too many attempts to start, control unit locked .............................................................. (0)50 Flame already present at switch-on (flame sensor > 62° or >1240 Ω)............................ (0)51 No start, safety time exceeded........................................................................................ (0)52 Flame interrupted: ⇒ During starting ............................................................................................................ (0)53 ⇒ At high speed.............................................................................................................. (0)54 ⇒ At medium speed ....................................................................................................... (0)55 ⇒ At low speed............................................................................................................... (0)56 External temperature control sensor: ⇒ Interruption > 2800 Ω.................................................................................................. (0)60 ⇒ Short-circuit < 280 Ω .................................................................................................. (0)61 Control box potentiometer: ⇒ Interruption >2800 Ω (normal value 1750 Ω to 2080 Ω ±80 Ω) .................................. (0)62 ⇒ Short-circuit < 280 Ω (normal value 1750 Ω to 2080 Ω ±80 Ω) .................................. (0)63 Flame sensor or flame sensor lead: ⇒ Interruption > 3200 Ω.................................................................................................. (0)64 ⇒ Short-circuit < 200 Ω .................................................................................................. (0)65 Overheating sensor, interruption > 3200 Ω or short-circuit <200 Ω ................................ (0)71 Control unit defective ...................................................................................................... (0)90 External interference voltage .......................................................................................... (0)91 Control unit defective: ⇒ ROM error .................................................................................................................. (0)92 ⇒ RAM error................................................................................................................... (0)93 ⇒ EEPROM fault ............................................................................................................ (0)94 ⇒ Internal temperature sensor defective ........................................................................ (0)96 ⇒ Oscillator or undervoltage fault................................................................................... (0)97 If the fault code is read out with an Eberspächer diagnosis unit, it has 3 digits (e.g. 021). If it is read out with the module clock, it has only 2 digits (e.g. 21). SD 206-2.97 Page 33 of 62
  • 34. DREIHA control box Reading out the fault memory − Switch on ignition − Press buttons 1 and 2 simultaneously for > 2 seconds After 3 seconds the flashcode is emitted via the check lamp 3 . After emission of the first fault code the display is automatically interrupted. For the next fault code buttons 1 and 2 must be pressed again for at least 2 seconds. 3 1 2 Erasing the fault memory − Switch off ignition − Press buttons 1 and 2 simultaneously and keep them pressed − Switch on ignition and release buttons 1 and 2 after 2 seconds Dark phase before emission ............................................................................ approx. 3 s Duration of a ten............................................................................................... approx. 2 s Duration of a unit .............................................................................................. approx. 0.5 s Pause between a ten and a ten........................................................................ approx. 1 s Pause between a ten and a unit ....................................................................... approx. 3 s Pause between a unit and a unit ...................................................................... approx. 1 S Example of flashcode: Fault code 12 on Lamp 3 in control box off SD 206-2.97 Page 34 of 62
  • 35. Type of fault Flashcode Valve: (check cabling to heater or drive in heater) ⇒ Short-circuit .....................................................................................................................11 ⇒ Interruption ......................................................................................................................12 ⇒ Stepping error..................................................................................................................13 Button defective (change control box)..................................................................................21 Short-circuit in blower...........................................................................................................26 Interruption in blower............................................................................................................27 Passenger compartment flap drive: short-circuit..................................................................31 Passenger compartment flap drive: interruption ..................................................................32 Footwell flap drive: short-circuit ...........................................................................................33 Footwell flap drive: interruption ............................................................................................34 Window flap drive: short-circuit............................................................................................35 Window flap drive: interruption.............................................................................................36 Fresh-air flap: short-circuit ...................................................................................................37 Fresh-air flap: interruption ....................................................................................................38 Air-conditioning flap: short-circuit.........................................................................................39 Air-conditioning flap: interruption..........................................................................................41 Output: ⇒ V short-circuit ..................................................................................................................43 ⇒ V interruption ...................................................................................................................44 ⇒ W short-circuit .................................................................................................................45 ⇒ W interruption..................................................................................................................46 ⇒ X short-circuit...................................................................................................................47 ⇒ X interruption ...................................................................................................................48 ⇒ Y short-circuit...................................................................................................................49 ⇒ Y interruption ...................................................................................................................51 ⇒ Z short-circuit...................................................................................................................52 ⇒ Z interruption ...................................................................................................................53 Fault in memory (change control box)..................................................................................54 SD 206-2.97 Page 35 of 62
  • 36. BEHR air-conditioner Reading out the fault memory − Switch off ignition and connect up request button − Switch on ignition − Press button for at least 2 seconds When the first fault code has been emitted display of further codes will be automatically in- terrupted. for the next fault code the button must be pressed again for at least 2 seconds. Duration of a ten............................................................................................... approx. 2 s Duration of a unit .............................................................................................. approx. 0.5 s Pause between a ten and a unit ....................................................................... approx. 3 s Pause between a unit and a unit ...................................................................... approx. 1 s Pause between a ten and a ten........................................................................ approx. 1 s Pause before emission of flashcode ................................................................ approx. 3 s Example of flashcode: Fault code 13 Lamp in on request button off Erasing the fault memory − Switch off ignition and connect up request button − Press button and keep it pressed − Switch on ignition and release button after > 2 seconds SD 206-2.97 Page 36 of 62
  • 37. Type of fault Flashcode Temperature sensor: ⇒ Interior (IF): short-circuit to earth.......................................................................................1 ⇒ Interior (IF): short-circuit to +UB or interruption.................................................................2 ⇒ Exterior (AF): short-circuit to earth ....................................................................................3 ⇒ Exterior (AF): short-circuit to +UB or interruption ..............................................................4 ⇒ Heat exchanger (TF): short-circuit to earth........................................................................5 ⇒ Heat exchanger (TF):short-circuit to +UB or interruption...................................................6 ⇒ Evaporator (VF): short-circuit to earth ...............................................................................7 ⇒ Evaporator (VF): short-circuit to +UB or interruption .........................................................8 Compressor coupling: short-circuit to earth, +UB or interruption ...........................................9 Water clock valve: short-circuit to earth or interruption........................................................11 Water clock valve: short-circuit to +UB ................................................................................12 Blower relay: short-circuit to earth or interruption .............................................................. *13 Blower relay: short-circuit to +UB....................................................................................... *14 Coding not stored in control unit...........................................................................................15 Coding stored does not correspond to the components dependent on the control unit............................................................................................................................16 * For air-conditioner only Connection diagram for request button X201 X204 SD 206-2.97 Page 37 of 62
  • 38. WABCO ATC (Automatic Temperature Control) heater/air-conditioner control Reading out the fault memory − Switch off ignition and connect up request button − Switch on ignition − Press button for at least 2 seconds When the first fault code has been emitted, display of further fault codes will be automati- cally interrupted. For further codes the button must be pressed again for at least 2 seconds. Duration of a ten............................................................................................... approx. 2 s Duration of a unit .............................................................................................. approx. 0.5 s Pause between a ten and a ten........................................................................ approx. 1 s Pause between a ten and a unit ....................................................................... approx. 3 s Pause between a unit and a unit ...................................................................... approx. 1 s Pause before flashcode emission .................................................................... approx. 3 s Example of flashcode: Fault code 13 Lamp in on request button off Erasing the fault memory − Switch off ignition and connect up request button − Press button and keep it pressed − Switch on ignition − Release button after > 2 seconds an < 4 seconds SD 206-2.97 Page 38 of 62
  • 39. Type of fault Flashcode Control unit defective (cumulative test fault, fan curves)........................................................1 Control unit defective (cumulative test fault, setting data)......................................................2 Spec. temperature transmitter, short-circuit to +UBatt ...........................................................3 Spec. temperature transmitter, short-circuit to earth/interruption in cable..............................4 Temperature sensor: ⇒ Evaporator, short-circuit to +UBatt ....................................................................................6 ⇒ Evaporator, short-circuit to earth .......................................................................................7 ⇒ evaporator, interruption in cable........................................................................................8 ⇒ Inside air, short-circuit to +UBatt .......................................................................................9 ⇒ Inside air, short-circuit to earth ........................................................................................10 ⇒ Inside air, interruption in cable ........................................................................................11 ⇒ Air outlet, short-circuit to +UBatt .....................................................................................12 ⇒ Air outlet, short-circuit to earth ........................................................................................13 ⇒ Air outlet, interruption in cable.........................................................................................14 ⇒ External air, short-circuit to +UBatt..................................................................................15 ⇒ External air, short-circuit to earth.....................................................................................16 ⇒ External air, interruption in cable.....................................................................................17 Mode switch defective..........................................................................................................18 Control unit defective (cumulative test fault, calibration data)..............................................21 Connection diagram for request button X204 SD 206-2.97 Page 39 of 62
  • 40. Automated pre-selector shift (AVS) Reading out the fault memory − Turn rotary switch to neutral position − Hold stalk switch in "Plus" position The fault codes are emitted on the gear display as long as the stalk switch is held in the "Plus" position. Erasing the fault memory − Possible only with MAN-cats Type of fault Display Short-circuit to earth: ⇒ Solenoid valve Y6 (Y135)................................................................................................21 ⇒ Solenoid valve Y1 (Y135)................................................................................................23 ⇒ Solenoid valve Y2 (Y135)................................................................................................24 ⇒ Solenoid valve Y3 (Y135)................................................................................................25 ⇒ Solenoid valve Y4 (Y135)................................................................................................26 ⇒ Solenoid valve Y5 (Y135)................................................................................................27 ⇒ Solenoid valve Y8 (Y135)................................................................................................28 ⇒ Lamp for substitute driving program switch (S167) .........................................................34 ⇒ Solenoid valve, confirm (Y137) .......................................................................................35 ⇒ Clutch retention valve (136).............................................................................................36 Interruption or short-circuit to +UB: ⇒ Solenoid valve Y6 (Y135)................................................................................................41 ⇒ Solenoid valve Y1 (Y135)................................................................................................43 ⇒ Solenoid valve Y2 (Y135)................................................................................................44 ⇒ Solenoid valve Y3 (Y135)................................................................................................45 ⇒ Solenoid valve Y4 (Y135)................................................................................................46 ⇒ Solenoid valve Y5 (Y135)................................................................................................47 ⇒ Solenoid valve Y8 (Y135)................................................................................................48 ⇒ Lamp for substitute driving program switch (S167) .........................................................54 ⇒ Solenoid valve, confirm (Y137) .......................................................................................55 ⇒ Clutch retention valve (136).............................................................................................56 Gearbox in neutral signal missing / Gear engaged signal does not drop out.......................61 Gear engaged signal: ⇒ Missing during shifting.....................................................................................................62 ⇒ Missing without shifting ...................................................................................................63 Group engaged signal does not drop out if group is engaged, or drops out and is no longer present...................................................................................64 Group engaged signal drops out without shifting and is no longer present..........................65 Overrevving during gearshift ................................................................................................66 Gear engaged signal and gearbox in neutral signals present simultaneously .....................67 Voltage from actual value transmitter (B138) or duty factor of PWM interface: ⇒ too low (cable 74502) ......................................................................................................71 ⇒ too high (cable 74502).....................................................................................................72 SD 206-2.97 Page 40 of 62
  • 41. Type of fault Display Supply voltage from actual value transmitter (B138): ⇒ too low .............................................................................................................................73 ⇒ too high............................................................................................................................74 Battery voltage: ⇒ too low .............................................................................................................................75 ⇒ too high............................................................................................................................76 Signal from speed pickup (B135) faulty ...............................................................................77 Signal from tachograph missing...........................................................................................78 Fault in stalk switch (S157) / pre-selector switch (S171) .....................................................81 Cable 40502 to display (A145) disturbed.............................................................................82 Short-circuit to earth (more detailed analysis not possible) .................................................83 Mechanical defect in gearbox/wrong control unit .................................................................84 Substitute driving program has been activated ....................................................................88 Control unit defective ...........................................................................................................91 Control unit defective ...........................................................................................................92 Control unit defective ...........................................................................................................93 SD 206-2.97 Page 41 of 62
  • 42. RENK DOROMAT Reading out the fault memory − Switch off ignition and set gearbox to neutral − Connect up request button − Switch on ignition and press button for > 2.5 seconds The fault codes are emitted only via the gearbox oil temperature check lamp. If no fault has been stored, the gearbox oil temperature check lamp goes out after the lamp test and remains out. If a fault has been stored, the fault code will be emitted 6 seconds after the lamp test. The display is interrupted automatically after the first fault code. For further fault codes the but- ton must be pressed again for > 2.5 seconds. Duration of a ten............................................................................................... approx. 2 s Duration of a unit .............................................................................................. approx. 0.5 s Dark period between a ten and a unit .............................................................. approx. 3 s Dark period between a unit and a unit.............................................................. approx. 1 s Dark period between a ten and a ten ............................................................... approx. 1 s Example of flashcode: Fault code 13 Lamp in on request button off 2.5 seconds (lamp test) Erasing the fault memory − Switch off ignition and connect up request button − Press button and keep it pressed − Switch on ignition and release button after > 2 seconds SD 206-2.97 Page 42 of 62
  • 43. Type of fault Flashcode 1st gear solenoid defective, cable or output stage.................................................................1 2nd gear solenoid defective, cable or output stage................................................................2 3rd gear solenoid defective, cable or output stage ................................................................3 4th gear solenoid defective, cable or output stage.................................................................4 Reverse gear solenoid defective, cable or output stage ........................................................5 Converter solenoid defective, cable or output stage ..............................................................6 Gearbox PTO defective, cable or output stage ......................................................................7 Modulation solenoid 1 defective cable or output stage ..........................................................9 Neutral solenoid defective, cable or output stage ................................................................11 Drive pickup (engine speed) defective, cable, output stage or earth fault in pickup ............12 Output pickup (road speed) defective, cable, output stage or earth fault in pickup..............13 Engine brake defective, cable or output stage .....................................................................14 Temperature lamp defective cable or output stage..............................................................15 Starter interlock defective, cable or output stage .................................................................16 Locking solenoid defective, cable or output stage ...............................................................17 Modulation solenoid 2 defective, cable or output stage .......................................................18 Connection diagram for request button X201 X211 SD 206-2.97 Page 43 of 62
  • 44. SAMT B Reading out the fault memory − Switch off ignition, set gearbox to neutral, do not depress the clutch − Switch on ignition − Move gearshift lever to downshift position and hold it there − Briefly switch ignition off and on again (once only) − Read off fault codes at gear display, thereby keeping the gearshift lever in the downshift position. A buzzer sounds after the last fault code and the display switches back to neutral − Release gearshift lever Erasing the fault memory − Switch off ignition and set gearbox to neutral. Do not depress the clutch − Switch on ignition − Move gearshift lever to downshift position and hold it there − Briefly switch ignition off and on again twice − When the fault memory has been erased a buzzer briefly sounds and "00" appears briefly in the display. After this the display returns to neutral − Release gearshift lever Type of fault Flashcode Relay for power supply K314: ⇒ Short-circuit in coil to earth............................................................................................. A0 ⇒ Interruption in coil or short-circuit to +UBatt ................................................................... A1 Battery voltage too high ...................................................................................................... A2 Battery voltage too low........................................................................................................ A3 "Ignition on" signal missing ................................................................................................. A4 Voltage at XY switch unit too high....................................................................................... A5 Voltage at XY switch unit too low ........................................................................................ A6 Voltage supply for gearshift lever: short-circuit ................................................................... A7 Voltage supply for gear display, short-circuit ...................................................................... A8 Solenoid valve for low splitter range: ⇒ Short-circuit .................................................................................................................... B0 ⇒ Interruption or short-circuit to +UBatt ............................................................................. B1 Solenoid valve for high splitter range: ⇒ Short-circuit .................................................................................................................... B2 ⇒ Interruption or short-circuit to +UBatt ............................................................................. B3 Mechanical fault in slow splitter range ................................................................................ B4 Mechanical fault in high splitter range................................................................................. B5 "Splitter" switch defective.................................................................................................... B6 Solenoid valve for high range-change group: ⇒ Short-circuit .................................................................................................................... C0 ⇒ Interruption or short-circuit to +UBatt ............................................................................. C1 Solenoid valve for low range-change group: ⇒ Short-circuit .................................................................................................................... C2 ⇒ Interruption or short-circuit to +UBatt ............................................................................ C3 SD 206-2.97 Page 44 of 62
  • 45. Type of fault Flashcode Mechanical fault in high range-change group...................................................................... C4 Mechanical fault in low range-change group....................................................................... C5 "Range-change" switch defective........................................................................................ C6 Short-circuit in solenoid valve for clutch or external short-circuit ........................................ D0 Interruption or short-circuit to +UBatt in solenoid valve for clutch....................................... D1 Fault in data cable between SAMT control unit in cab and SAMT control unit on gearbox .......................................................................................................................... E0 Fault in CAN data bus: ⇒ between SAMT control unit and EDC control unit .......................................................... E1 ⇒ between SAMT control unit and retarder control unit ..................................................... E2 ⇒ between SAMT control unit and ABS/ASR control unit .................................................. E3 ⇒ general communication fault, SAMT control unit switched off ........................................ E4 Fault in data cable between SAMT control unit and gear display, or faulty data transfer ..........................................................................................................EE Fault in SAMT control unit (cab).......................................................................................... F0 Fault in SAMT control unit (gearbox)................................................................................... F1 Current at X motor of XY switch unit ................................................................................... H0 Interruption or short-circuit to earth at X motor of XY switch unit ........................................ H1 X potentiometer outside normal operating range ................................................................ H2 "Gate selector rail" cannot be triggered .............................................................................. H3 Current at Y motor of XY switch unit ....................................................................................J0 Interruption or short-circuit to earth at Y motor of XY switch unit .........................................J1 Y potentiometer outside normal operating range .................................................................J2 One forward gear cannot be triggered .................................................................................J3 One reverse gear cannot be triggered .................................................................................J4 Neutral position cannot be triggered ....................................................................................J5 Signal from countershaft speed sensor missing...................................................................L0 Signal from mainshaft speed sensor missing.......................................................................L1 Signal from output shaft speed sensor missing....................................................................L2 Solenoid valve for gearbox brake: ⇒ Short-circuit .................................................................................................................... U0 ⇒ Interruption or short-circuit to +UBatt ............................................................................. U1 Reservoir air pressure to gearbox too low .......................................................................... U2 Position of gearshift lever illogical; up- and downshift requested simultaneously at SAMT control unit in cab or short-circuit to +UBatt ............................... U3 SD 206-2.97 Page 45 of 62
  • 46. VOITH DIWA.3 Reading out the fault memory − Switch off ignition and connect up request button − Switch on ignition − Press button for > 2 seconds Emission of the flashcode begins after 3 seconds. When the first fault code has been emit- ted emission of further codes is automatically interrupted. For the next fault the button must be pressed again for at least 2 seconds. Duration of a flash ............................................................................................ approx. 0.5 s Pause between a hundred and a hundred........................................................ approx. 1 s Pause between a hundred and a ten................................................................ approx. 3 s Pause between a ten and a ten........................................................................ approx. 1 s Pause between a ten and a unit ...................................................................... approx. 3 s Pause between a unit and a unit ...................................................................... approx. 1 s Example of flashcode: Fault code 221 on Lamp in request button off Erasing the fault memory − Switch off ignition and connect up request button − Press button and keep it pressed − Switch on ignition and release button after > 2 seconds Connection diagram for request button X211 SD 206-2.97 Page 46 of 62
  • 47. Type of fault Flashcode Sensor: ⇒ Input speed....................................................................................................................221 ⇒ Output speed .................................................................................................................222 ⇒ Turbine speed................................................................................................................223 ⇒ Oil temperature..............................................................................................................224 Input clutch .........................................................................................................................331 Through clutch....................................................................................................................332 Clutch for 4th gear..............................................................................................................333 Pump brake........................................................................................................................334 Converter brake, small piston ............................................................................................335 Turbine brake .....................................................................................................................336 Pressure, converter outlet valve WP..................................................................................337 Pressure, converter outlet valve WR .................................................................................338 Converter brake, large piston.............................................................................................339 Control element REA1 .......................................................................................................341 Relays: ⇒ Control ...........................................................................................................................342 ⇒ Converter brake.............................................................................................................343 ⇒ Speed switch .................................................................................................................344 ⇒ Reversing lights.............................................................................................................345 Button lighting ....................................................................................................................346 Bus-stop brake relay ..........................................................................................................347 Relay, adhesion display .....................................................................................................348 Central warning lamp .........................................................................................................358 Gearbox oil warning lamp ..................................................................................................359 Service brake .....................................................................................................................361 Parking brake .....................................................................................................................362 Load pickup........................................................................................................................363 Button.................................................................................................................................364 Control reset.......................................................................................................................391 Software .............................................................................................................................392 REA0 control element ........................................................................................................399 Monitoring controller...........................................................................................................451 Supply voltage....................................................................................................................481 Control pressure.................................................................................................................499 SD 206-2.97 Page 47 of 62
  • 48. Voith-Retarder Reading out the fault memory − Retarder step switch in zero position. Switch off ignition and connect up request button − Switch on ignition − Press button for > 2 seconds When the first fault code has been emitted, emission of further codes will be automatically interrupted. For the next fault the button must be pressed again for at least 2 seconds. Duration of a ten............................................................................................... approx. 2 s Duration of a unit .............................................................................................. approx. 1 s Dark phase....................................................................................................... approx. 1 s Example of flashcode: Fault code 12 on Lamp in request button off Erasing the fault memory − Retarder step switch in zero position. 0, Switch off ignition and connect up request button. − Press button and keep it pressed − Switch on ignition and release button after >2 seconds. Connection diagram for request button X207 SD 206-2.97 Page 48 of 62
  • 49. Type of fault Flashcode Relay, retarder operation in stages, short-circuit to earth ......................................................1 Output, relay for speed reduction, short-circuit to +UBatt ......................................................2 Engine brake relay, short-circuit to earth ...............................................................................3 LED output in stage switch, short-circuit to earth ...................................................................4 PIN X1/7, undervoltage (< 17,5 Volt) .....................................................................................5 PIN X1/7, overvoltage (> 32,5 Volt) .......................................................................................6 Water temperature sensor: ⇒ Interruption or short-circuit to UBatt (> 2000 Ohm) ...........................................................8 ⇒ Short-circuit to earth (< 600 Ohm).....................................................................................9 Oil temperature sensor: ⇒ Interruption or short-circuit to UBatt (> 2000 Ohm) .........................................................11 ⇒ Short-circuit to earth (< 600 Ohm)...................................................................................12 Stage switch: ⇒ Undefined switching status..............................................................................................13 ⇒ Short-circuit to UBatt .......................................................................................................14 ⇒ Short-circuit to earth ........................................................................................................15 Speedo signal, interruption ..................................................................................................16 Speedo signal, short-circuit to UBatt or undefined signal ....................................................18 ABS signal, short-circuit to earth..........................................................................................19 ABS signal, signal level undefined.......................................................................................21 ABS signal, internal fault in Digiprop control unit .................................................................22 Fault in prop. valve: ⇒ Short-circuit to UBatt at prop. valve, or control unit defective .........................................23 ⇒ Short-circuit in prop. valve solenoid, short-circuit in prop. valve cable, interruption in prop. valve solenoid, interruption in prop. valve cable, short-circuit to earth at prop. valve ..................................................................................24 ⇒ Control unit defective.......................................................................................................25 ⇒ Control unit defective.......................................................................................................26 ⇒ Control unit defective.......................................................................................................27 PIN X1/13, undervoltage (< 17.5 Volt) .................................................................................28 Internal fault relating to safety module .................................................................................29 Data record / parameters, faulty coding ...............................................................................31 Retarder operation lamp: ⇒ Interruption or short-circuit to earth .................................................................................32 ⇒ Short-circuit to UBatt .......................................................................................................33 Engine speed signal missing................................................................................................34 Internal fault relating to ROM / EEPROM.............................................................................35 SD 206-2.97 Page 49 of 62
  • 50. ZF-Retarder (Intarder) Reading out the fault memory − Switch off ignition and connect up request button − Switch on ignition − Press request button for > 2 seconds The flashcode is emitted after 3 seconds. After the first fault code emission of further codes is automatically interrupted. For the next fault code the button must be pressed again for at least 2 seconds. Duration of a ten............................................................................................... approx. 2 s Duration of a unit .............................................................................................. approx. 1 s Dark phase between a ten and a unit............................................................... approx. 2 s Dark phase between a unit and a unit .............................................................. approx. 1 s Dark phase between a ten and a ten................................................................ approx. 1 s Example of flashcode: Fault code 22 Lamp in on request button off Erasing the fault memory − Switch off ignition and connect up request button − Press button and keep it pressed − Switch on ignition and release button after > 2 seconds SD 206-2.97 Page 50 of 62
  • 51. Type of fault Flashcode Charge valve, interruption ....................................................................................................21 Intarder check lamp, interruption..........................................................................................22 Charge valve, short-circuit ...................................................................................................41 Intarder check lamp, short-circuit .........................................................................................42 Brake light, short-circuit........................................................................................................44 Coolant temperature sensor: ⇒ Short-circuit or < 1000 Ohm ............................................................................................51 ⇒ Interruption or > 400 kOhm..............................................................................................55 Brake stage switch, signal combination implausible ............................................................66 Output speed sensor, interruption or short-circuit ................................................................77 Proportional solenoid, interruption .......................................................................................88 Overvoltage in vehicle electrics > +38Volt...........................................................................99 Connection diagram for request button X201 X207 X207 SD 206-2.97 Page 51 of 62
  • 52. ZF HP500 Reading out the fault memory − Switch off ignition and connect up request button − Switch on ignition − Press request button for > seconds If no fault has been stored, the lamp goes out when the button is pressed. If a fault is pres- ent, emission of the flashcode begins after 3 seconds. After emission of the first fault code emission is automatically interrupted. For the next fault code the button must be pressed again for at least 2 seconds. Duration of a ten............................................................................................... approx. 2 s Duration of a unit .............................................................................................. approx. 1 s Dark phase between a ten and a unit............................................................... approx. 2 s Dark phase between a unit and a unit .............................................................. approx. 1 s Dark phase between a ten and a ten................................................................ approx. 1 s Example of flashcode: Fault code 23 on Lamp in request button off Erasing the fault memory − Switch off ignition and connect up request button − Press button and keep it pressed − Switch on ignition and release button after > 3 seconds Connection diagram for request button X201 X211 X211 SD 206-2.97 Page 52 of 62
  • 53. Type of fault Flashcode Slip fault ...............................................................................................................................11 Slipping time too long (gear change 1->2) ...........................................................................12 Slipping time too long (gear change 2-->3)..........................................................................13 Slipping time too long (gear change 3-->4)..........................................................................14 Slipping time too long (gear change 4-->5)..........................................................................15 Slipping time too long (gear change 5-->6)..........................................................................16 Slipping time too long (gear change 6-->7)..........................................................................17 Slipping time too long (gear change 7-->8)..........................................................................18 Load pickup faulty, tap voltage too high/low ........................................................................23 Output speed sensor faulty ..................................................................................................25 Turbine speed sensor faulty .................................................................................................27 Speedo output SD3: ⇒ Short-circuit to 24 Volt .....................................................................................................28 ⇒ Short-circuit to earth ........................................................................................................29 Short-circuit to earth ⇒ Brake G, cable 45 AD1....................................................................................................31 ⇒ Brake F, cable 44 AD 2 ...................................................................................................32 ⇒ Brake E, cable 42 AD 3 ...................................................................................................33 ⇒ Brake D, cable 39 AD 4...................................................................................................34 ⇒ Clutch C, cable 4 AD 5 ....................................................................................................35 ⇒ Clutch B, cable 22 AD 6 ..................................................................................................36 ⇒ Clutch A, cable 3 AD 7 ....................................................................................................37 ⇒ Converter clutch WK, cable 1 AD 8.................................................................................38 ⇒ Retarder output, cable 49 AD 9 .......................................................................................39 ⇒ Engine brake output, cable 50 AD 10..............................................................................40 ⇒ Engine brake output, cable 53 AD 11..............................................................................41 ⇒ V signal, cable 55 AD 12 .................................................................................................42 ⇒ PTO output, cable 11 AD 13............................................................................................43 ⇒ Antigas signal, cable 30 AD 14 .......................................................................................44 ⇒ Load reduction/gear signal 1, cable 12 AD 15 ................................................................45 ⇒ Bar magnet/fault display (H1), cable 54 AD 16 ...............................................................46 Interruption or short-circuit to 24 Volt ⇒ Brake G, cable G.............................................................................................................51 ⇒ Brake F, cable F ..............................................................................................................52 ⇒ Brake E, cable E..............................................................................................................53 ⇒ Clutch D, cable D ............................................................................................................54 ⇒ Clutch C, cable C ............................................................................................................55 SD 206-2.97 Page 53 of 62
  • 54. Type of fault Flashcode Interruption or short-circuit to 24 Volt ⇒ Clutch B, cable B.............................................................................................................56 ⇒ Clutch A, cable A.............................................................................................................57 ⇒ Converter clutch, cable WK.............................................................................................58 ⇒ Retarder output, check lamp not working, cable 1 BN2 ..................................................59 ⇒ Engine brake output, engine brake not working, cable 12 BN2.......................................60 ⇒ Retarder reduction output, retarder not reduced, cable 632............................................61 ⇒ V signal 1, cable 5 BN1 ...................................................................................................62 ⇒ PTO output, cable 6 BN2.................................................................................................63 ⇒ Antigas signal, cable 4 BN2 ............................................................................................64 ⇒ Load reduction/gear signal 2, cable 9 BN2 .....................................................................65 ⇒ Bar magnet/fault display (driving switch lamp), cable 15 BN2 ........................................66 Load pickup, incorrect setting ..............................................................................................71 Driving switch defective/interrupted .....................................................................................73 Vehicle electrics faulty .........................................................................................................75 Constricted pressure valve, fault at current output AI1 ........................................................77 Load pickup, supply voltage faulty .......................................................................................79 SD 206-2.97 Page 54 of 62
  • 55. EMS 3.3 Reading out the fault memory − Switch off ignition and connect up request button − Switch on ignition and press button for > 1 second The flashcode is emitted only via the E-Gas lamp, not via the lamp in the request button. Erasing the fault memory − Switch off ignition and connect up request button − Press button and keep it pressed − Switch on ignition and release button after > 1 second Type of fault Flashcode No fault...................................................................................................................................1 Control unit defective .............................................................................................................2 Actuator check-back...............................................................................................................3 Pedal potentiometer 1, fault ...................................................................................................4 Actuator fault ..........................................................................................................................5 Pedal potentiometer, signal not identical with that from pedal potentiometer 2.....................6 Speed signal fault...................................................................................................................7 ASR interface fault .................................................................................................................8 Pedal potentiometer 2, fault ...................................................................................................9 Road speed fault (cruise control) .........................................................................................10 Actuator current, fault ...........................................................................................................11 Actuator, learning fault .........................................................................................................12 Speed signal (signal fault)....................................................................................................13 Control unit trigger to solenoid valve, engine stop is interrupted .........................................14 Connection diagram for request button X70 X201 X210 X210 SD 206-2.97 Page 55 of 62
  • 56. EDC M7 Reading out the fault memory − Switch off ignition and connect up request button − Diagram A for control units up to end of 990 (290/300/330 hp) − Diagram B for control unit from 1991 onwards (320/420 hp) − Remove feet from clutch and brake pedals (otherwise the fault code will be erased) − Switch on ignition − Press button for > 2 seconds After emission of the first fault code further emission is automatically interrupted. For the further fault codes the button must be pressed again for at least 2 seconds. Example of flashcode: Fault code 5 Lamp in on request button off Erasing the fault memory (290/300/330 hp with control units up to end of 1990) − Switch off ignition and connect up request button in accordance with diagram (A) − Switch on ignition − Press request button and at the same time actuate clutch or brake pedal Erasing the fault memory (320/420 hp with control units from 1991 onwards) − Switch off ignition and connect up request button in accordance with diagram (B) − Press button and keep it pressed − Switch on ignition − Release button after > 3 seconds SD 206-2.97 Page 56 of 62
  • 57. Type of fault Flashcode Pedal value transmitter defective...........................................................................................1 Fuel temperature sensor (only for 290/300/330 hp) ...............................................................2 Charge air temperature sensor ..............................................................................................3 System speed pickup in mechanism......................................................................................4 Boost pressure sensor ...........................................................................................................5 Control rod travel pickup in mechanism .................................................................................6 Coolant temperature sensor...................................................................................................7 Road speed pickup: no signal or fault in signal......................................................................8 Idling switch in pedal value transmitter faulty (with 320/420 hp only) ....................................9 Quantity mechanism, system deviation................................................................................10 Not occupied ........................................................................................................................11 Not occupied ........................................................................................................................12 Control unit defective ...........................................................................................................13 Auxiliary speed sensor: no signal (terminal W))...................................................................14 Control unit defective ...........................................................................................................15 Connection diagram for request button: A B X116 X201 X210 SD 206-2.97 Page 57 of 62
  • 58. EDC MS5 Reading out the fault memory − Switch off ignition and connect up request button − Switch on ignition − Press button for > seconds After emission of the first fault code further emission is automatically interrupted. For further fault codes the button must be pressed again for at least 2 seconds. Pause before first emission.............................................................................. approx. 3 s Duration of a long flash .................................................................................... approx. 2 s Duration of a short flash ................................................................................... approx. 0.5 s Pause between two short flashes..................................................................... approx. 0.5 s Pause between a long and a short flash .......................................................... approx. 5 s Pause between two long flashes...................................................................... approx. 1 s Example of flashcode: Fault code, 1x long, 4x short Lamp in on request button off Erasing the fault memory − Switch off ignition and connect up request button − Press button and keep it pressed − Switch on ignition − Release button after > 2.5 seconds and < 10 seconds Connection diagram for request button X201 X210 X210 SD 206-2.97 Page 58 of 62
  • 59. Type of fault Please observe SI 97 04 22/2 Flashcode long short Pedal value transmitter ...........................................................................................- .............1 Charge air temperature sensor ...............................................................................- .............3 Primary speed sensor .............................................................................................- .............4 Boost pressure sensor ............................................................................................- .............5 Control rod recording in mechanism .......................................................................- .............6 Coolant temperature sensor....................................................................................- .............7 Road speed pickup .................................................................................................- .............8 Idling switch in pedal value transmitter ...................................................................- .............9 Quantity mechanism (system deviation) .................................................................- ...........10 Auxiliary speed sensor ............................................................................................- ...........14 Fuel temperature sensor ........................................................................................1 .............1 Battery undervoltage ..............................................................................................1 .............3 Brake proximity switch ...........................................................................................1 .............4 Clutch proximity switch...........................................................................................1 .............5 Control unit (computer link) ....................................................................................1 .............6 Overrevving............................................................................................................1 .............7 Start of injection, system deviation ........................................................................1 .............8 Boost pressure controller, system deviation ..........................................................1 .............9 Needle movement sensor ......................................................................................1 ...........10 Mechanical defect in needle movement sensor (needle sticks).............................1 ...........11 Multistage switch for torque limiter.........................................................................1 ...........12 Control element (stalk switch) ................................................................................1 ...........13 ASR interface .........................................................................................................1 ...........14 Control unit (CAN module) .....................................................................................1 ...........15 CAN signal, ASR2..................................................................................................2 .............1 CAN signal, gearbox control ..................................................................................2 .............3 Idling switch in pedal value transmitter, plausibility with brake ..............................2 .............4 Main relay...............................................................................................................2 .............5 Multistage switch, top speed ..................................................................................2 .............7 Atmospheric pressure sensor (in control unit)........................................................2 .............8 CAN signal from ASR to retarder ...........................................................................2 ...........10 CAN signal from gearbox to retarder .....................................................................2 ...........11 CAN signal from vehicle management to engine brake .........................................2 ...........12 CAN signal from vehicle management...................................................................2 ...........13 CAN signal from gearbox to EDC ..........................................................................2 ...........14 Control unit (computer after-running not completed, EHAB) ..................................3 .............1 Control unit defective (computer 1 defective).........................................................3 .............2 Control unit defective (computer 2 defective).........................................................3 .............3 External stop recording ..........................................................................................3 .............4 Boost pressure control VTG...................................................................................3 .............5 Intercooling bypass ................................................................................................3 .............6 After-running not complete .....................................................................................3 .............8 After-running watchdog fault ..................................................................................3 .............9 SD 206-2.97 Page 59 of 62
  • 60. VDO speed limiter AGB-S Reading out the fault memory − Switch off ignition and connect up request button − Switch on ignition and wait for 2 seconds − Press button for > 2 seconds Emission is automatically interrupted after emission of the first fault code. For further fault codes the button must be pressed again for at least 2 seconds. Dark phase before emission ............................................................................ approx. 3 s Duration of long flash ....................................................................................... approx. 2 s Duration of short flash ...................................................................................... approx. 0.5 s Pause between a long and a short flash .......................................................... approx. 3 s Pause between two short flashes..................................................................... approx. 1 s Pause between two long flashes...................................................................... approx. 1 s Example of flashcode: Fault code 1x long and 2x short flashes Lamp in on request button off Erasing the fault memory − Switch off ignition and connect up request button − Press button and keep it pressed − Switch on ignition and release button after > 2 seconds SD 206-2.97 Page 60 of 62
  • 61. Type of fault Flashcode long short Clutch switch, if present .............................................................................................1 .........2 Road speed signal, cable, short-circuit to earth or cable capacity too high ........................................................................................................2 .........2 Road speed signal, cable open or short-circuit to +UB or signal fault .......................2 .........4 Servomotor, potentiometer cable(s)...........................................................................3 .........1 Fault in signal path for terminal W .............................................................................3 .........2 Program fault, (control unit defective) ........................................................................3 .........3 Configuration error, data out of tolerance...................................................................3 .........5 Servomotor cable, short-circuit to +UB ......................................................................4 .........1 Servomotor cable, short-circuit to earth .....................................................................4 .........2 Servomotor, internal short-circuit ...............................................................................4 .........3 Servomotor or servomotor cable interrupted..............................................................4 .........4 Positioning fault, servomotor incorrectly adjusted......................................................4 .........5 Connection diagram for request button X201 X210 X210 SD 206-2.97 Page 61 of 62
  • 62. WABCO air injection Reading out the fault memory − Switch off ignition and connect up request button − Switch on ignition − Press button for at least 2 seconds Erasing the fault memory − Switch off ignition and connect up request button − Press button and keep it pressed − Switch on ignition − Release button after > 2 seconds Type of fault Flashcode Control unit defective: ⇒ Cumulative test, ROM .......................................................................................................1 ⇒ Cumulative test, Wabco data ............................................................................................2 ⇒ Cumulative test, parameters .............................................................................................3 ⇒ RAM cells defective...........................................................................................................4 Solenoid valve path: ⇒ Short-circuit .......................................................................................................................5 ⇒ Interruption ........................................................................................................................6 Connection diagram for request button x201 x208 x208 SD 206-2.97 Page 62 of 62