                         WIRING STANDARD
                         There are two wiring standards for network cabling, T568a and T568b. We will
                         be discussing using the T568b specification.

                         It is essential that you DO NOT MIX T568a and T568b on the same
                         network.

                         USE HIGH QUALITY CAT 5e or CAT 6 cabling
                         Audio files are generally very large data files and need to be moved around the
                         network as quickly as possible. All the computers sold by BSI are capable of
                         network transfer at 1 Gbps (a Gigabit) full-duplex; however your existing
                         network cabling, switches and routers may not be capable of supporting this
                         speed and may only operate at the more common 100 Mbps,

                         Whilst generally it is possible to utilize good quality Cat 5 cabling for Gigabit
                         networks, we highly recommend that you stick to the ‘in spec’ Cat 5e standard
                         or highly quality Cat 6 cabling and wire for Gigabit connectivity even if your
                         existing network switches and routers only support 100 Mbps. This will then
                         ensure that the cabling infrastructure is in place when the Gigabit routers and
                         switches are more readily available.

                         The rest of the points apply equally to 1Gbps and 100 Mbps connections – each
                         can be affected badly by poor cabling / wrong connections.

                         In high RF environments, it is also essential to use ‘shielded twisted pair’ (STP)
                         rather than ‘unshielded twisted pair’ to prevent interference.

                         HAVE GOOD CABLES RUNS
                         Cabling between each of the computers should be in a ‘star’ configuration with
                         each computer having a separate cable run to the central switch and / or router.

                         Each cable should be no longer than 265 feet and should be a single piece of
                         cable (there should be no joins).
info@bsiusa.com
www.bsiusa.com
Ph. 541.338.8588         Cabling should NOT be run next to electrical mains cabling (because of the
Fax 541.338.8656
                         potential for interference); nor should network cabling be suspended on ceiling
                         tiles (this may violate building code and fire regulations).

                                         BSI Network Cabling Guide – Page 1
As typically network cabling uses solid wire, cabling should not be twisted or bent into a tight
radius.

Do not use metal staples to secure cable runs, nor tightly adjusted cable wraps.

We recommend that you ‘flood’ wire any new facility with Cat 5e or higher specification wiring,
preferably to professional RJ45 patch bays.

This is because as well as network connections, this wiring can also be used for telephone systems
and network cabling makes excellent audio cabling runs (the capacitance of the network cable is
such as to allow high-bandwidth, high-speed data to transfer and is perfect for both analog and
digital audio).

USE THE RIGHT PLUGS!
Network connections use RJ45 plugs which look similar but are not the same as telephone plugs
(which are RJ11). Cables are inserted into the plug and a special tool is used to make the connection
between the plug-pins and the cabling – do not try to do this with a screw-driver or pair of pliers!

Typically, cabling will be made up of pairs of ‘solid’ or ‘single-core’ wires rather than the more
flexible stranded wire often used in patch cables.

RJ45 plugs are designed for either just stranded or just solid cable but usually not both. It’s virtually
impossible to tell the difference by looking at the plugs themselves – you need to be sure that you
specify the correct plugs when ordering them.




                                                         RJ45 Plug with 8 pins

                                                        (Viewed from this angle,
                                                         pin 8 is on the left and
                                                          pin 1 is on the right)




                                                          RJ11 Telephone Plug
                                                                 with
                                                            only four pins.




                                     BSI Network Cabling Guide – Page 2
DO NOT UNTWIST MORE THAN 0.25” OF CABLE
Network cabling comprises of 4 pairs of twisted wires which are color coded (Orange, Green, Blue
and Brown).

The cable specification is such that it has been designed for high-speed data-transfer and very little
cross-talk (interference between pairs of wires).

It is very important that no more than about a quarter of an inch of the cable is untwisted at either
end as this can lead to problems such as ‘near end cross-talk’ which will have a detrimental affect on
your network.

KEEP THE PAIRS TOGETHER & WIRE CORRECTLY!
As previously mentioned, network cabling comprises of four pairs of wires, although only two pairs
are normally used. Despite this, all the pairs should always be wired to maintain the network
specification. The cable pair colors, pair numbers and wire descriptions are shown in the table
below.

                               COLOR            PAIR       DESCRIPTION
                            White / Blue                   Unused
                                                   1
                            Blue                           Unused
                            White / Orange                 Transmit Data +
                                                   2
                            Orange                         Transmit Data -
                            White / Green                  Receive Data +
                                                   3
                            Green                          Receive Data -
                            White / Brown                  Unused
                                                   4
                            Brown                          Unused

Confusingly, the ‘pairs’ in the RJ45 plug run across the following pins. It is essential that you wire
the plug correctly and not just from pins 1 through 8 at both ends (note that in this example, the
‘hook’ on the plug is facing the front):

                          RJ45 PIN             PAIR                 COLOR
                             1                                 White / Orange
                                                  2
                             2                                 Orange
                             3                    3            White / Green
                             4                                 Blue
                                                  1
                             5                                 White / Blue
                             6                    3            Green
                             7                                 White / Brown
                                                  4
                             8                                 Brown




                                     BSI Network Cabling Guide – Page 3
IDENTIFYING PIN NUMBERS
RJ45 plugs have a little ‘hook’ that locks the plug into the socket as can be seen from the enlarged
images below. Take time to study the orientation of the plug.




Now flip the plug over so that the ‘pins’ are on top, the ‘hook’ underneath and the cable entry
towards you and from left to right will be pins 1 to 8…both cable ends are normally wired the same.




The above wiring conforms to the T568b specification and is used for connections between a
computer and hub; computer and switch; computer and router; and computer and cable modem.


                                     BSI Network Cabling Guide – Page 4
CROSSOVER CABLE
There are instances where you need to connect two devices such as a switch and a hub together, or a
router and cable modem together which involves the Transmit pair of cables on one device talking to
the Receive pair of the other device.

Typically, these devices will be fitted with an ‘uplink’ port and you should plug one end of the cable
into the uplink port of one device only as the uplink port automatically crosses over the Transmit and
Receive pairs in the device itself so that the two devices can ‘talk’ to each other.

If an uplink port is not available, you will have to wire a cross-over cable at one end of a standard
RJ45 cable, the diagram below shows first the standard cable end followed by the crossed over cable
end.

                                    STANDARD CABLE END




One cable end should be wired as above, in the standard configuration. The other end should be
wired as cross-over. Note that the Orange and Green Pairs are now crossed over.

                                   CROSSOVER CABLE END




                                    BSI Network Cabling Guide – Page 5
USE THE CORRECT TERMINATING TOOL!
As stated before, do not attempt to crimp the RJ45 plug using a screwdriver, metal block or pair of
pliers! If you are going to be wiring network cabling, it is worth investing in a high-quality crimping
tool.

The better ones will crimp RJ45 and telephone connectors and contain metal blades to cut the
network cabling and strip the outer cable cover back and are very easy to use.




CONSIDER USING PATCH PANELS
If you are installing network cabling at a new facility, we strongly suggest that you wire cabling to
an RJ45 patch panel. Each room should be ‘flood wired’ with ample RJ45 sockets that can then be
patched as either Network (data), Telephone (voice), or Analog or Digital Audio.




                                     BSI Network Cabling Guide – Page 6

More Related Content

PPT
Cabling
PDF
Cabling
DOC
5. what is network cabling
PPTX
network cabling
PPTX
Data Comm | Making Ethernet Cable
PPTX
2019 types of network cables
PDF
Copper Cable - TDII2016 S
PPTX
Netwok cable(edisi bahasa kebangsan)
Cabling
Cabling
5. what is network cabling
network cabling
Data Comm | Making Ethernet Cable
2019 types of network cables
Copper Cable - TDII2016 S
Netwok cable(edisi bahasa kebangsan)

What's hot (20)

PPTX
Networking - UTP and STP Cable - Straight and Crossover - By Mark John Lado
PPTX
Network cable
PPTX
Local And Wide Area Networking (Networking Media - Physical Cable)
PPT
Chapter10
PPTX
Network Cabling
PPTX
types of network cables
PDF
High Speed Data Cables
PPTX
Types of Ethernet Cable
PDF
Network cables
PPTX
How to connect networking cables
PPTX
Cables in Computer Networks
DOCX
What is cat5e cabling
PPT
Twisted pair cable
PPTX
The Features of Structured Cabling
PDF
Fiber optic patch cord knowledge
PPTX
Network Cabling
DOCX
What is a data cable
PPTX
Twisted pair cable
PPT
Dsl & leasedline.61
Networking - UTP and STP Cable - Straight and Crossover - By Mark John Lado
Network cable
Local And Wide Area Networking (Networking Media - Physical Cable)
Chapter10
Network Cabling
types of network cables
High Speed Data Cables
Types of Ethernet Cable
Network cables
How to connect networking cables
Cables in Computer Networks
What is cat5e cabling
Twisted pair cable
The Features of Structured Cabling
Fiber optic patch cord knowledge
Network Cabling
What is a data cable
Twisted pair cable
Dsl & leasedline.61
Ad

Similar to Network Cabling Guide | Cat5, Cat6, Cat7 (20)

PPTX
New Computer Network Practical 01 SYBSCit.pptx
PPT
4. RJ45 Wiring Guide Diagram.ppt
PPTX
LAN Cabling.pptx
PPTX
Presentation.pptx
PDF
7.3.2.6 lab build and test network cables
PDF
How to configure rj45 pinout
PPTX
LAN Cabling
PPTX
Crimping - RJ45.pptx
PPTX
Network Cabling
PPTX
3. UTP AND FIBER CABLING.pptx
DOCX
Cnlab ex.no.1
PPTX
Networking lab manual LAB SESSION 1 PPT.pptx
PPTX
manual Networking LAB SESSION 1 PPT.pptx
PPT
LO 02 Network Cabling.ppt
PPT
Networking Basics
PDF
Making stright and crossover cables and crimping
DOCX
Straight through ethernet cable color coding
PPT
Networking Basics
PDF
CSS L14 - ETHERNET CABLING
PPTX
Cabling Straight Through and Crossover.pptx
New Computer Network Practical 01 SYBSCit.pptx
4. RJ45 Wiring Guide Diagram.ppt
LAN Cabling.pptx
Presentation.pptx
7.3.2.6 lab build and test network cables
How to configure rj45 pinout
LAN Cabling
Crimping - RJ45.pptx
Network Cabling
3. UTP AND FIBER CABLING.pptx
Cnlab ex.no.1
Networking lab manual LAB SESSION 1 PPT.pptx
manual Networking LAB SESSION 1 PPT.pptx
LO 02 Network Cabling.ppt
Networking Basics
Making stright and crossover cables and crimping
Straight through ethernet cable color coding
Networking Basics
CSS L14 - ETHERNET CABLING
Cabling Straight Through and Crossover.pptx
Ad

Recently uploaded (20)

PDF
How to Get Approval for Business Funding
PDF
Deliverable file - Regulatory guideline analysis.pdf
PDF
Nante Industrial Plug Factory: Engineering Quality for Modern Power Applications
PDF
kom-180-proposal-for-a-directive-amending-directive-2014-45-eu-and-directive-...
PDF
Daniels 2024 Inclusive, Sustainable Development
PDF
IFRS Notes in your pocket for study all the time
PDF
Technical Architecture - Chainsys dataZap
PDF
Digital Marketing & E-commerce Certificate Glossary.pdf.................
PPTX
Astra-Investor- business Presentation (1).pptx
PDF
Solara Labs: Empowering Health through Innovative Nutraceutical Solutions
PPTX
svnfcksanfskjcsnvvjknsnvsdscnsncxasxa saccacxsax
PDF
Solaris Resources Presentation - Corporate August 2025.pdf
PDF
Blood Collected straight from the donor into a blood bag and mixed with an an...
PDF
Ôn tập tiếng anh trong kinh doanh nâng cao
PDF
NEW - FEES STRUCTURES (01-july-2024).pdf
PDF
Charisse Litchman: A Maverick Making Neurological Care More Accessible
PDF
TyAnn Osborn: A Visionary Leader Shaping Corporate Workforce Dynamics
PDF
Introduction to Generative Engine Optimization (GEO)
PDF
Keppel_Proposed Divestment of M1 Limited
PDF
Module 2 - Modern Supervison Challenges - Student Resource.pdf
How to Get Approval for Business Funding
Deliverable file - Regulatory guideline analysis.pdf
Nante Industrial Plug Factory: Engineering Quality for Modern Power Applications
kom-180-proposal-for-a-directive-amending-directive-2014-45-eu-and-directive-...
Daniels 2024 Inclusive, Sustainable Development
IFRS Notes in your pocket for study all the time
Technical Architecture - Chainsys dataZap
Digital Marketing & E-commerce Certificate Glossary.pdf.................
Astra-Investor- business Presentation (1).pptx
Solara Labs: Empowering Health through Innovative Nutraceutical Solutions
svnfcksanfskjcsnvvjknsnvsdscnsncxasxa saccacxsax
Solaris Resources Presentation - Corporate August 2025.pdf
Blood Collected straight from the donor into a blood bag and mixed with an an...
Ôn tập tiếng anh trong kinh doanh nâng cao
NEW - FEES STRUCTURES (01-july-2024).pdf
Charisse Litchman: A Maverick Making Neurological Care More Accessible
TyAnn Osborn: A Visionary Leader Shaping Corporate Workforce Dynamics
Introduction to Generative Engine Optimization (GEO)
Keppel_Proposed Divestment of M1 Limited
Module 2 - Modern Supervison Challenges - Student Resource.pdf

Network Cabling Guide | Cat5, Cat6, Cat7

  • 1. Network Cabling Guide Poor or incorrectly installed network cabling can cause numerous problems with your computer network. Whilst we recommend that you employ a network / cabling specialist to wire and configure your network, we have compiled some important information to help you avoid some of the more common pitfalls. It is very important to understand that a problem with your network 1925 Bailey Hill Road, Suite A cabling, however small it may appear, can have a catastrophic effect on the Eugene, OR 97405 operation of your audio network. WIRING STANDARD There are two wiring standards for network cabling, T568a and T568b. We will be discussing using the T568b specification. It is essential that you DO NOT MIX T568a and T568b on the same network. USE HIGH QUALITY CAT 5e or CAT 6 cabling Audio files are generally very large data files and need to be moved around the network as quickly as possible. All the computers sold by BSI are capable of network transfer at 1 Gbps (a Gigabit) full-duplex; however your existing network cabling, switches and routers may not be capable of supporting this speed and may only operate at the more common 100 Mbps, Whilst generally it is possible to utilize good quality Cat 5 cabling for Gigabit networks, we highly recommend that you stick to the ‘in spec’ Cat 5e standard or highly quality Cat 6 cabling and wire for Gigabit connectivity even if your existing network switches and routers only support 100 Mbps. This will then ensure that the cabling infrastructure is in place when the Gigabit routers and switches are more readily available. The rest of the points apply equally to 1Gbps and 100 Mbps connections – each can be affected badly by poor cabling / wrong connections. In high RF environments, it is also essential to use ‘shielded twisted pair’ (STP) rather than ‘unshielded twisted pair’ to prevent interference. HAVE GOOD CABLES RUNS Cabling between each of the computers should be in a ‘star’ configuration with each computer having a separate cable run to the central switch and / or router. Each cable should be no longer than 265 feet and should be a single piece of cable (there should be no joins). info@bsiusa.com www.bsiusa.com Ph. 541.338.8588 Cabling should NOT be run next to electrical mains cabling (because of the Fax 541.338.8656 potential for interference); nor should network cabling be suspended on ceiling tiles (this may violate building code and fire regulations). BSI Network Cabling Guide – Page 1
  • 2. As typically network cabling uses solid wire, cabling should not be twisted or bent into a tight radius. Do not use metal staples to secure cable runs, nor tightly adjusted cable wraps. We recommend that you ‘flood’ wire any new facility with Cat 5e or higher specification wiring, preferably to professional RJ45 patch bays. This is because as well as network connections, this wiring can also be used for telephone systems and network cabling makes excellent audio cabling runs (the capacitance of the network cable is such as to allow high-bandwidth, high-speed data to transfer and is perfect for both analog and digital audio). USE THE RIGHT PLUGS! Network connections use RJ45 plugs which look similar but are not the same as telephone plugs (which are RJ11). Cables are inserted into the plug and a special tool is used to make the connection between the plug-pins and the cabling – do not try to do this with a screw-driver or pair of pliers! Typically, cabling will be made up of pairs of ‘solid’ or ‘single-core’ wires rather than the more flexible stranded wire often used in patch cables. RJ45 plugs are designed for either just stranded or just solid cable but usually not both. It’s virtually impossible to tell the difference by looking at the plugs themselves – you need to be sure that you specify the correct plugs when ordering them. RJ45 Plug with 8 pins (Viewed from this angle, pin 8 is on the left and pin 1 is on the right) RJ11 Telephone Plug with only four pins. BSI Network Cabling Guide – Page 2
  • 3. DO NOT UNTWIST MORE THAN 0.25” OF CABLE Network cabling comprises of 4 pairs of twisted wires which are color coded (Orange, Green, Blue and Brown). The cable specification is such that it has been designed for high-speed data-transfer and very little cross-talk (interference between pairs of wires). It is very important that no more than about a quarter of an inch of the cable is untwisted at either end as this can lead to problems such as ‘near end cross-talk’ which will have a detrimental affect on your network. KEEP THE PAIRS TOGETHER & WIRE CORRECTLY! As previously mentioned, network cabling comprises of four pairs of wires, although only two pairs are normally used. Despite this, all the pairs should always be wired to maintain the network specification. The cable pair colors, pair numbers and wire descriptions are shown in the table below. COLOR PAIR DESCRIPTION White / Blue Unused 1 Blue Unused White / Orange Transmit Data + 2 Orange Transmit Data - White / Green Receive Data + 3 Green Receive Data - White / Brown Unused 4 Brown Unused Confusingly, the ‘pairs’ in the RJ45 plug run across the following pins. It is essential that you wire the plug correctly and not just from pins 1 through 8 at both ends (note that in this example, the ‘hook’ on the plug is facing the front): RJ45 PIN PAIR COLOR 1 White / Orange 2 2 Orange 3 3 White / Green 4 Blue 1 5 White / Blue 6 3 Green 7 White / Brown 4 8 Brown BSI Network Cabling Guide – Page 3
  • 4. IDENTIFYING PIN NUMBERS RJ45 plugs have a little ‘hook’ that locks the plug into the socket as can be seen from the enlarged images below. Take time to study the orientation of the plug. Now flip the plug over so that the ‘pins’ are on top, the ‘hook’ underneath and the cable entry towards you and from left to right will be pins 1 to 8…both cable ends are normally wired the same. The above wiring conforms to the T568b specification and is used for connections between a computer and hub; computer and switch; computer and router; and computer and cable modem. BSI Network Cabling Guide – Page 4
  • 5. CROSSOVER CABLE There are instances where you need to connect two devices such as a switch and a hub together, or a router and cable modem together which involves the Transmit pair of cables on one device talking to the Receive pair of the other device. Typically, these devices will be fitted with an ‘uplink’ port and you should plug one end of the cable into the uplink port of one device only as the uplink port automatically crosses over the Transmit and Receive pairs in the device itself so that the two devices can ‘talk’ to each other. If an uplink port is not available, you will have to wire a cross-over cable at one end of a standard RJ45 cable, the diagram below shows first the standard cable end followed by the crossed over cable end. STANDARD CABLE END One cable end should be wired as above, in the standard configuration. The other end should be wired as cross-over. Note that the Orange and Green Pairs are now crossed over. CROSSOVER CABLE END BSI Network Cabling Guide – Page 5
  • 6. USE THE CORRECT TERMINATING TOOL! As stated before, do not attempt to crimp the RJ45 plug using a screwdriver, metal block or pair of pliers! If you are going to be wiring network cabling, it is worth investing in a high-quality crimping tool. The better ones will crimp RJ45 and telephone connectors and contain metal blades to cut the network cabling and strip the outer cable cover back and are very easy to use. CONSIDER USING PATCH PANELS If you are installing network cabling at a new facility, we strongly suggest that you wire cabling to an RJ45 patch panel. Each room should be ‘flood wired’ with ample RJ45 sockets that can then be patched as either Network (data), Telephone (voice), or Analog or Digital Audio. BSI Network Cabling Guide – Page 6