SlideShare a Scribd company logo
2
Most read
4
Most read
6
Most read
Omkar Electronics, Thane, Elevator Components
Omkar Electronics, Thane, Elevator Components
NGLC-Single Speed Lift Controller :
NGLC Single speed Passenger
Lift controller with LCD Display
G+7, Down collective
TO CONTROL
HURDLE FOR SMOOTH RIDING
Features of single speed elevator controller
• State-of-art design with Low voltage and High voltage
separation in PCB layout.
• LCD display to show shaft faults, car gate – landing gate –
limit switches position – current position and destination of
car, all pending calls, etc.
• Counting type car top reeds – only two reeds, one for up
direction and second for down direction.
• 16 digit alphanumeric password for counter for lift stopping
after defined predetermined time, e.g. one day, one week,
one month or two months, etc.
• Three stage safety chain for customer, avoiding accidental
shorting of safeties by trainee technician. In no condition a
technician can short entire safety of lift.
• Floor setting is field settable.
OMKARELECTRONICSELECTRONICS
NGLC Single speed Passenger
Lift controller with LCD Display
G+7, Down collective
• As all relays are on same board maintenance
becomes simple.
• Aextra safety relay introduced on board to enhance
passenger safety.
NGLC-Single Speed Lift Controller :
OMKAR ELECTRONICSAN ISO 9001:2008 company
NAIC-CRISIL
SE 3B
JAS-ANZ Regd. Office & Works :
Plot No. K-3, Udyog Bhavan 2, “A” Wing, F-7, 1st Floor, Additional Ambernath, MIDC,
Anand Nagar, Ambernath (E) - 421 506. Dist. Thane, Maharashtra State. INDIA.
Tel No.: 0251-2621040
OMKARELECTRONICSELECTRONICS
Email : sale.omkar@yahoo.com / omkar_electronics@ymail.com
Website : omkarelectronics.net
TO CONTROL
SMALL LEAP TO HIGHEST ALTITUDE
Features of V3F or multi speed elevator controller
• State-of-art design with Low voltage and High voltage
separation in PCB layout.
• 7 segment common anode display output.
• LCD display to show shaft faults, car gate – landing gate –
limit switches position – current position and destination of
car, all pending calls, etc.
• Single wire registration i.e. only one off wire from button.
• Counting type car top reeds – Only two reeds, one for up
direction slowing and second for down direction slowing
and two more reeds, one for up direction stopping and
second for down direction stopping.
• 16 digit alphanumeric password for counter for lift stopping
after defined predetermined time, e.g. one day, one week,
one month or two months, etc.
• On board optical isolation from field wiring.
• Three stage safety chain for customer, avoiding accidental
shorting of safeties by trainee technician. In no condition a
technician can short entire safety of lift.
• Car gate and landing gate voltage 110v.
• There are six limit switches – three on top floor and three on
ground floor. All limit switches are 110, for reliable intended
operation. Reed switches are not allowed in place of limit
NGLC- V3F Lift Controller : For Geared Motor-AutoDoor/ManualDoor
OMKARELECTRONICSELECTRONICS
switches, according to Bombay Lift rules.
• All limit switches are NC according to
Bombay Lift Rules.
• Output contactor for motor, for isolating
motor from source, according to Bombay
Lift Rules.
• Extra brake relay in PCB to take care of
drive becoming faulty. In any case is drive
hangs or becomes non-responsive
during running, this relay comes in picture
and avoids accident.
• Separate R-cam contactor for New type
locks.
• As all components are of SMD
technology, life of components increases
because of reduced oxidation of contact
and junctions.
• DOB, Auto Fan, Auto / Manual doors
relays are also available on-board.
• Floor setting is field settable.
ADVANTAGES OF OGEN2 OVER OGEN1
1) Output contactor feedback taken as per ISI
recommendationandinternationalnorms.
2) Brake contactor feedback taken as per ISI
recommendationandinternationalnorms.
3) Single wire display available to reduce digital
display wiring andtravellingcable.
4) Six pre-programmed 7 segment display groups as
per requirement of customer are available to
selectaspersitedenominations.
5) Customer encoding software for particular
customer is possible in digital displays along with
16 digit alphanumeric password for business
retention.
6) ARD input and output introduced as per
international standards.
7) Overload and Full load inputs introduced in
software.
8) Anti nuisance logics incorporated as per
internationalnorms.
9) Separate two relays for UP and DOWN command
fordriveinterfacing.
10) DooropenandDoorcloserelaysseperate.
11) Auto door / Manual door selection in controller
card.
12) Dooropentimesiteselectable.
13) RunTimerintroduced.
14) Anti-creep input added in software for hydraulic
controller.
15) Emergencystopinputavailable.
16) LowcostDuplexcontrolleravailable.
OGEN 2
OGEN 1
NGLC- V3F Lift Controller : For Geared Motor-AutoDoor/ManualDoor
OMKAR ELECTRONICSAN ISO 9001:2008 company
NAIC-CRISIL
SE 3B
JAS-ANZ Regd. Office & Works :
Plot No. K-3, Udyog Bhavan 2, “A” Wing, F-7, 1st Floor, Additional Ambernath, MIDC,
Anand Nagar, Ambernath (E) - 421 506. Dist. Thane, Maharashtra State. INDIA.
Tel No.: 0251-2621040
OMKARELECTRONICSELECTRONICS
Email : sale.omkar@yahoo.com / omkar_electronics@ymail.com
Website : omkarelectronics.net
ARD Controller (Universal) – Auto Door & Manual Door
TO CONTROL IT TO
NEW LEVELS OF EXCELLENCE
FEATURES –
1) Can be interfaced with any controller either single speed
or V3F.
2) Only safety chain of main controller needs to be routed
from this controller.
3) Terminal limit switches of main controller can also be
interfaced optionally.
4) Inclusive with battery and battery charger.
5) Motor supply, brake, Retiring Cam and auto door supply
are connected parallel to existing supply and becomes
active only duringARD operation.
6) Saves battery life and improves number of starts because
of current sensing.
OMKARELECTRONICSELECTRONICS
FUNCTIONING OF ARD CONTROLLER –
1) There is small adjustable delay in
taking over of ARD operation after
power shut down to accommodate
mechanical stabilization of entire
system and to protect gear box.
2) Once system stabilizes, and safety
chain is detected, inverter section
starts and 110vdc is generated to
activate R Cam.
3) Then motor rotates once clockwise
and once anti-clockwise and
compares current in both
directions. And continues to run in
the direction where current
consumption is low to save
batteries.
ARD Controller (Universal) – Auto Door & Manual Door
OMKAR ELECTRONICSAN ISO 9001:2008 company
NAIC-CRISIL
SE 3B
JAS-ANZ Regd. Office & Works :
Plot No. K-3, Udyog Bhavan 2, “A” Wing, F-7, 1st Floor, Additional Ambernath, MIDC,
Anand Nagar, Ambernath (E) - 421 506. Dist. Thane, Maharashtra State. INDIA.
Tel No.: 0251-2621040
OMKARELECTRONICSELECTRONICS
Email : sale.omkar@yahoo.com / omkar_electronics@ymail.com
Website : omkarelectronics.net
NGLC – MRL – Geared OR Gearless
Features of MRL controller
• Full collective, G+10.
• Only external UPS is required as ARD, all other switchgear
is inbuilt.
• 7 segment common anode display output.
• LCD display to show shaft faults, car gate – landing gate –
limit switches position – current position and destination of
car, all pending calls, etc.
• Single wire registration i.e. only one off wire from button.
• Counting type car top reeds – Only two reeds, one for up
direction slowing and second for down direction slowing
and two more reeds, one for up direction stopping and
second for down direction stopping.
• 16 digit alphanumeric password for counter for lift stopping
after defined predetermined time, e.g. one day, one week,
one month or two months, etc.
• On board optical isolation from field wiring.
• Three stage safety chain for customer, avoiding accidental
shorting of safeties by trainee technician. In no condition a
technician can short entire safety of lift.
• Car gate and landing gate voltage 110v.
• There are six limit switches – three on top floor and three on
Ground floor.All limit switches are 110, for reliable intended
TO CONTROL
SPEED TO THE HIGHEST LEVEL
OMKARELECTRONICSELECTRONICS
operation. Reed switches are not allowed in place of limit
switches, according to Bombay Lift rules.
• All limit switches are NC according to Bombay Lift
Rules.
• Output contactor for motor, for isolating motor from
source, according to Bombay Lift Rules.
• Extra brake relay in PCB to take care of drive becoming
faulty. In any case is drive hangs or becomes non-
responsive during running, this relay comes in picture
and avoids accident.
• DOB, Auto Fan, Auto / Manual doors relays are also
available on-board.
• Floor setting is field settable.
NGLC – MRL – Geared OR Gearless
OMKAR ELECTRONICSAN ISO 9001:2008 company
NAIC-CRISIL
SE 3B
JAS-ANZ Regd. Office & Works :
Plot No. K-3, Udyog Bhavan 2, “A” Wing, F-7, 1st Floor, Additional Ambernath, MIDC,
Anand Nagar, Ambernath (E) - 421 506. Dist. Thane, Maharashtra State. INDIA.
Tel No.: 0251-2621040
OMKARELECTRONICSELECTRONICS
Email : sale.omkar@yahoo.com / omkar_electronics@ymail.com
Website : omkarelectronics.net
NGLC - Hydraulic Controllers up to G+7
Features of Hydraulic elevator controller
• State-of-art design with Low voltage and High voltage
separation in PCB layout.
• 7 segment common anode display output.
• LCD display to show shaft faults, car gate – landing gate –
limit switches position – current position and destination of
car, all pending calls, etc.
• Single wire registration i.e. only one off wire from button.
• Counting type car top reeds – Only two reeds, one for up
direction slowing and second for down direction slowing
and two more reeds, one for up direction stopping and
second for down direction stopping.
• 16 digit alphanumeric password for counter for lift stopping
after defined predetermined time, e.g. one day, one week,
one month or two months, etc.
• On board optical isolation from field wiring.
• Anti-creep input available.
• Three stage safety chain for customer, avoiding accidental
shorting of safeties by trainee technician.
• Car gate and landing gate voltage 110v.
TO CONTROL TOUCH FOR
BETTER EXPERIENCE LEVEL
OMKARELECTRONICSELECTRONICS
• There are six limit switches – three on top floor and three on
Ground floor. All limit switches are 110, for reliable intended
operation. Reed switches are not allowed in place of limit
switches, according to Bombay Lift rules.
• All limit switches are NC according to Bombay Lift Rules.
• Output contactor for motor, for isolating motor from source,
according to Bombay Lift Rules.
• Separate R-cam contactor for New type locks.
• As all components are of SMD technology, life of
components increases because of reduced oxidation of
contact and junctions.
• DOB, Auto Fan, Auto / Manual doors relays are also
available on-board.
• Floor setting is field settable.
NGLC - Hydraulic Controllers up to G+7
OMKAR ELECTRONICSAN ISO 9001:2008 company
NAIC-CRISIL
SE 3B
JAS-ANZ Regd. Office & Works :
Plot No. K-3, Udyog Bhavan 2, “A” Wing, F-7, 1st Floor, Additional Ambernath, MIDC,
Anand Nagar, Ambernath (E) - 421 506. Dist. Thane, Maharashtra State. INDIA.
Tel No.: 0251-2621040
OMKARELECTRONICSELECTRONICS
Email : sale.omkar@yahoo.com / omkar_electronics@ymail.com
Website : omkarelectronics.net
TO CONTROL THE BEST OUT OF OTHER
Home Lift Controller - Gearless Motor
Features of Home elevator controller
• Works on only single phase supply, hence suitable for home
installation.
• Cost of ARD also reduces as only single ph UPS works as
ARD.
• Down collective, G+7
• 7 segment common anode display output.
• LCD display to show shaft faults, car gate – landing gate –
limit switches position – current position and destination of
car, all pending calls, etc.
• Single wire registration i.e. only one off wire from button.
• Counting type car top reeds – Only two reeds, one for up
direction slowing and second for down direction slowing
and two more reeds, one for up direction stopping and
second for down direction stopping.
• 16 digit alphanumeric password for counter for lift stopping
after defined predetermined time, e.g. one day, one week,
one month or two months, etc.
• On board optical isolation from field wiring.
OMKARELECTRONICSELECTRONICS
• Three stage safety chain for customer, avoiding
accidental shorting of safeties by trainee technician. In
no condition a technician can short entire safety of lift.
• Car gate and landing gate voltage 12v.
• There are six limit switches – three on top floor and
three on ground floor. All limit switches are 110, for
reliable intended operation. Reed switches are not
allowed in place of limit switches, according to Bombay
Lift rules.
• All limit switches are NC according to Bombay Lift
Rules.
• Output contactor for motor, for isolating motor from
source, according to Bombay Lift Rules.
• Extra brake relay in PCB to take care of drive becoming
faulty. In any case if drive hangs or becomes non-
responsive during running, this relay comes in picture
and avoids accident.
• DOB, Auto Fan, Auto / Manual doors relays are also
available on-board.
• Floor setting is field settable.
Home Lift Controller - Gearless Motor
OMKAR ELECTRONICSAN ISO 9001:2008 company
NAIC-CRISIL
SE 3B
JAS-ANZ Regd. Office & Works :
Plot No. K-3, Udyog Bhavan 2, “A” Wing, F-7, 1st Floor, Additional Ambernath, MIDC,
Anand Nagar, Ambernath (E) - 421 506. Dist. Thane, Maharashtra State. INDIA.
Tel No.: 0251-2621040
OMKARELECTRONICSELECTRONICS
Email : sale.omkar@yahoo.com / omkar_electronics@ymail.com
Website : omkarelectronics.net
0.75 sq. mm 4 core Round or Flat
Wire Harness
Wire harness costing will depend on floor heights
and other options, it will be quoted time to time.
Travelling cable –
# Wire rates are volatile and
depend on fluctuations of
copper and pvc prices hence
kindly enquire at the time of
ordering.
# Our wire is ISI approved.
Round or Flat0.5 sq. mm
0.75 sq. mm
0.5 sq. mm
12 core
12 core
6 core Round or Flat
Round or Flat
Single Core Wire
0.5 sq. mm
0.75 sq. mm
1 sq. mm
1.5 sq. mm
2 sq. mm
4 sq. mm
Advantages of Harness –
1. Time required to do wiring reduces from 6
man-days to half man-day.
2. Wiring Error possibilities are reduced to
zero.
3. No wastage or theft of costly wires.
4. No necessity of Expert Engineer for wiring of
that particular controller.
5. Maintenance of lift becomes easy as every
wire has ferrule to denominate the signal. A
engineer sitting in office can direct and solve
site problems by technicians, without
visiting site.
6. As every contact has copper lugs, life of
installation increases by reducing oxidation
of contacts.
7. Man power retention cost incurred in
maintaining expert people in organisation
reduces drastically.
8. Inventory reduces to zero and Just-in-time
technique is employed by user along with
Just-as-required. No wire need to be
purchased extra.
OMKARELECTRONICSELECTRONICS
Accessories
OMKAR ELECTRONICSAN ISO 9001:2008 company
NAIC-CRISIL
SE 3B
JAS-ANZ Regd. Office & Works :
Plot No. K-3, Udyog Bhavan 2, “A” Wing, F-7, 1st Floor, Additional Ambernath, MIDC,
Anand Nagar, Ambernath (E) - 421 506. Dist. Thane, Maharashtra State. INDIA.
Tel No.: 0251-2621040
1) Controller card for NGLC-
Single Speed up to G+7 with LCD
2) Controller card for NGLC - V3F
up to G+7 with LCD
3) Controller card for NGLC -
G+15 Dn coll / G+10 Full coll with LCD
4) Reed s/w TVS make tubular
(pencil type)
5) DOB 6) ‘U’ type Magnetic shoe for
door zone
7) Fins (Cam) for Magnetic shoe
mounting arrangement for
auto door
8) Magnets 10) Heavy Duty Junction box set –
includes junction box – 2 nos,
maintenance box – 1 no,
motor wire (7/20) – 50 yards,
Beeper – 1 no,
Lugs for motor – 9 nos.
OMKARELECTRONICSELECTRONICS
Email : sale.omkar@yahoo.com / omkar_electronics@ymail.com
Website : omkarelectronics.net
9) Voice
announcement
systems up to
G+15 with
continuous music

More Related Content

PPTX
Fire alarm system and common types of detectors
PPTX
Air handling unit
PPT
Emergency Evacuation Procedures
DOC
Guidelines of Gas cylinder rule, By B C Das
PPTX
Clean agents fire suppression system- fm200, novec 1230 and ecaro 25
PDF
Access control system
PDF
Bms overview
PDF
Safety moment - Ear Protection
Fire alarm system and common types of detectors
Air handling unit
Emergency Evacuation Procedures
Guidelines of Gas cylinder rule, By B C Das
Clean agents fire suppression system- fm200, novec 1230 and ecaro 25
Access control system
Bms overview
Safety moment - Ear Protection

What's hot (9)

PDF
Luminarias led atex
PPTX
Hvac basics
PDF
High-Rise Building Disasters
PDF
Lecture 5 Fire Alarm System.pdf
PPT
Fire Safety
PPTX
Fire suppression
PPTX
Evolution of fire fighting equipment
PPTX
Fire safety first aid
PPT
EMERGENCY PLANNING
Luminarias led atex
Hvac basics
High-Rise Building Disasters
Lecture 5 Fire Alarm System.pdf
Fire Safety
Fire suppression
Evolution of fire fighting equipment
Fire safety first aid
EMERGENCY PLANNING
Ad

Viewers also liked (13)

PPT
Elevator controller for multi story building security
PDF
New Indian Elevators, Maharashtra, Elevator Components
PDF
Exploiting Elevator Security Weaknesses by Deviant Ollam
PDF
Breaking Vaults - Stealing Lastpass Protected Secrets by Martin Vigo
PPTX
An Introduction to Machine Learning
PPTX
Diagram of an elevator
PPTX
Elevator
PPT
Developing an Elevator Pitch
PPT
Thysse krupp introducing tke_nov_2014_16-9_final
PPTX
Elevator Controller
PPT
vertical-transportation (mechanical)
PDF
Elevator1
PDF
Bucket Elevator Basics: Definitions & Details
Elevator controller for multi story building security
New Indian Elevators, Maharashtra, Elevator Components
Exploiting Elevator Security Weaknesses by Deviant Ollam
Breaking Vaults - Stealing Lastpass Protected Secrets by Martin Vigo
An Introduction to Machine Learning
Diagram of an elevator
Elevator
Developing an Elevator Pitch
Thysse krupp introducing tke_nov_2014_16-9_final
Elevator Controller
vertical-transportation (mechanical)
Elevator1
Bucket Elevator Basics: Definitions & Details
Ad

Similar to Omkar Electronics, Thane, Elevator Components (20)

PPTX
DIGITAL DC DRIVES & SYSTEMS UPTO 5000 KW
PDF
DC Drive Manufacturers| Digital DC Drive Manufacturers
PPTX
Alcohol detection & driver safety
PPT
Final presentation
PDF
Automation,Remote, Sets, Caterpillar.pdf
PPTX
plc automation thapar university
PPT
Basic plc 1
PDF
plc_training_manual.pdf
PDF
JVL AC Servo Motor Controllers AMC20, AMC21 and AMC22
PPTX
Programmable Logic Controller Training Day 1 to 3.pptx
PPT
Basic plc
PPT
Basic plc
PPT
Basic plc
PPT
Basic plc
PPT
Basic plc
PPT
Basic plc
PPT
Basic plc
PPT
Basic plc
PPTX
Automatic Toll Tax Collection System by Using RFID
PPTX
Smart Gate
DIGITAL DC DRIVES & SYSTEMS UPTO 5000 KW
DC Drive Manufacturers| Digital DC Drive Manufacturers
Alcohol detection & driver safety
Final presentation
Automation,Remote, Sets, Caterpillar.pdf
plc automation thapar university
Basic plc 1
plc_training_manual.pdf
JVL AC Servo Motor Controllers AMC20, AMC21 and AMC22
Programmable Logic Controller Training Day 1 to 3.pptx
Basic plc
Basic plc
Basic plc
Basic plc
Basic plc
Basic plc
Basic plc
Basic plc
Automatic Toll Tax Collection System by Using RFID
Smart Gate

More from IndiaMART InterMESH Limited (20)

PDF
Welding Electrode Making Machine By Deccan Dynamics
PDF
Projectors By Egate Infotel Private Limited
PDF
Polyene General Industries Private Limited
PPTX
Anti Vibrations Pads By Dynemech System (P) Ltd.
PDF
Eagle Plant Protect Private Limited by Agro Chemical Products
PDF
Jatindra Engineering Corporation
PDF
Hindustan Fibre Tech
PDF
Automation Control Equipment By Dura Control Systems
PDF
Home Furnishing Products By Kent International
PPTX
Home Furnishing Products By Kent International
PDF
Bhavani Engineering Works
PDF
Jash Precision Tools Private Limited
PPTX
Coconut Processing Machines
PDF
PDF
Files, Folder, Executive Notebook & Dairies by Worldone Brand Of Arora Gifts ...
PDF
Weavetech Engineers Limited
PDF
Industrial Fasteners
Welding Electrode Making Machine By Deccan Dynamics
Projectors By Egate Infotel Private Limited
Polyene General Industries Private Limited
Anti Vibrations Pads By Dynemech System (P) Ltd.
Eagle Plant Protect Private Limited by Agro Chemical Products
Jatindra Engineering Corporation
Hindustan Fibre Tech
Automation Control Equipment By Dura Control Systems
Home Furnishing Products By Kent International
Home Furnishing Products By Kent International
Bhavani Engineering Works
Jash Precision Tools Private Limited
Coconut Processing Machines
Files, Folder, Executive Notebook & Dairies by Worldone Brand Of Arora Gifts ...
Weavetech Engineers Limited
Industrial Fasteners

Recently uploaded (20)

PDF
Building a Smart Pet Ecosystem: A Full Introduction to Zhejiang Beijing Techn...
PDF
Solara Labs: Empowering Health through Innovative Nutraceutical Solutions
PDF
IFRS Notes in your pocket for study all the time
PPTX
3. HISTORICAL PERSPECTIVE UNIIT 3^..pptx
PDF
Keppel_Proposed Divestment of M1 Limited
PDF
Introduction to Generative Engine Optimization (GEO)
PPTX
Board-Reporting-Package-by-Umbrex-5-23-23.pptx
PPTX
TRAINNING, DEVELOPMENT AND APPRAISAL.pptx
PDF
Cours de Système d'information about ERP.pdf
PDF
SIMNET Inc – 2023’s Most Trusted IT Services & Solution Provider
PDF
pdfcoffee.com-opt-b1plus-sb-answers.pdfvi
PDF
THE COMPLETE GUIDE TO BUILDING PASSIVE INCOME ONLINE
PPT
Lecture 3344;;,,(,(((((((((((((((((((((((
PDF
1911 Gold Corporate Presentation Aug 2025.pdf
PPTX
sales presentation، Training Overview.pptx
PDF
Outsourced Audit & Assurance in USA Why Globus Finanza is Your Trusted Choice
PDF
NISM Series V-A MFD Workbook v December 2024.khhhjtgvwevoypdnew one must use ...
PPTX
2025 Product Deck V1.0.pptxCATALOGTCLCIA
PDF
Nante Industrial Plug Factory: Engineering Quality for Modern Power Applications
PDF
ANALYZING THE OPPORTUNITIES OF DIGITAL MARKETING IN BANGLADESH TO PROVIDE AN ...
Building a Smart Pet Ecosystem: A Full Introduction to Zhejiang Beijing Techn...
Solara Labs: Empowering Health through Innovative Nutraceutical Solutions
IFRS Notes in your pocket for study all the time
3. HISTORICAL PERSPECTIVE UNIIT 3^..pptx
Keppel_Proposed Divestment of M1 Limited
Introduction to Generative Engine Optimization (GEO)
Board-Reporting-Package-by-Umbrex-5-23-23.pptx
TRAINNING, DEVELOPMENT AND APPRAISAL.pptx
Cours de Système d'information about ERP.pdf
SIMNET Inc – 2023’s Most Trusted IT Services & Solution Provider
pdfcoffee.com-opt-b1plus-sb-answers.pdfvi
THE COMPLETE GUIDE TO BUILDING PASSIVE INCOME ONLINE
Lecture 3344;;,,(,(((((((((((((((((((((((
1911 Gold Corporate Presentation Aug 2025.pdf
sales presentation، Training Overview.pptx
Outsourced Audit & Assurance in USA Why Globus Finanza is Your Trusted Choice
NISM Series V-A MFD Workbook v December 2024.khhhjtgvwevoypdnew one must use ...
2025 Product Deck V1.0.pptxCATALOGTCLCIA
Nante Industrial Plug Factory: Engineering Quality for Modern Power Applications
ANALYZING THE OPPORTUNITIES OF DIGITAL MARKETING IN BANGLADESH TO PROVIDE AN ...

Omkar Electronics, Thane, Elevator Components

  • 3. NGLC-Single Speed Lift Controller : NGLC Single speed Passenger Lift controller with LCD Display G+7, Down collective TO CONTROL HURDLE FOR SMOOTH RIDING Features of single speed elevator controller • State-of-art design with Low voltage and High voltage separation in PCB layout. • LCD display to show shaft faults, car gate – landing gate – limit switches position – current position and destination of car, all pending calls, etc. • Counting type car top reeds – only two reeds, one for up direction and second for down direction. • 16 digit alphanumeric password for counter for lift stopping after defined predetermined time, e.g. one day, one week, one month or two months, etc. • Three stage safety chain for customer, avoiding accidental shorting of safeties by trainee technician. In no condition a technician can short entire safety of lift. • Floor setting is field settable. OMKARELECTRONICSELECTRONICS
  • 4. NGLC Single speed Passenger Lift controller with LCD Display G+7, Down collective • As all relays are on same board maintenance becomes simple. • Aextra safety relay introduced on board to enhance passenger safety. NGLC-Single Speed Lift Controller : OMKAR ELECTRONICSAN ISO 9001:2008 company NAIC-CRISIL SE 3B JAS-ANZ Regd. Office & Works : Plot No. K-3, Udyog Bhavan 2, “A” Wing, F-7, 1st Floor, Additional Ambernath, MIDC, Anand Nagar, Ambernath (E) - 421 506. Dist. Thane, Maharashtra State. INDIA. Tel No.: 0251-2621040 OMKARELECTRONICSELECTRONICS Email : sale.omkar@yahoo.com / omkar_electronics@ymail.com Website : omkarelectronics.net
  • 5. TO CONTROL SMALL LEAP TO HIGHEST ALTITUDE Features of V3F or multi speed elevator controller • State-of-art design with Low voltage and High voltage separation in PCB layout. • 7 segment common anode display output. • LCD display to show shaft faults, car gate – landing gate – limit switches position – current position and destination of car, all pending calls, etc. • Single wire registration i.e. only one off wire from button. • Counting type car top reeds – Only two reeds, one for up direction slowing and second for down direction slowing and two more reeds, one for up direction stopping and second for down direction stopping. • 16 digit alphanumeric password for counter for lift stopping after defined predetermined time, e.g. one day, one week, one month or two months, etc. • On board optical isolation from field wiring. • Three stage safety chain for customer, avoiding accidental shorting of safeties by trainee technician. In no condition a technician can short entire safety of lift. • Car gate and landing gate voltage 110v. • There are six limit switches – three on top floor and three on ground floor. All limit switches are 110, for reliable intended operation. Reed switches are not allowed in place of limit NGLC- V3F Lift Controller : For Geared Motor-AutoDoor/ManualDoor OMKARELECTRONICSELECTRONICS
  • 6. switches, according to Bombay Lift rules. • All limit switches are NC according to Bombay Lift Rules. • Output contactor for motor, for isolating motor from source, according to Bombay Lift Rules. • Extra brake relay in PCB to take care of drive becoming faulty. In any case is drive hangs or becomes non-responsive during running, this relay comes in picture and avoids accident. • Separate R-cam contactor for New type locks. • As all components are of SMD technology, life of components increases because of reduced oxidation of contact and junctions. • DOB, Auto Fan, Auto / Manual doors relays are also available on-board. • Floor setting is field settable. ADVANTAGES OF OGEN2 OVER OGEN1 1) Output contactor feedback taken as per ISI recommendationandinternationalnorms. 2) Brake contactor feedback taken as per ISI recommendationandinternationalnorms. 3) Single wire display available to reduce digital display wiring andtravellingcable. 4) Six pre-programmed 7 segment display groups as per requirement of customer are available to selectaspersitedenominations. 5) Customer encoding software for particular customer is possible in digital displays along with 16 digit alphanumeric password for business retention. 6) ARD input and output introduced as per international standards. 7) Overload and Full load inputs introduced in software. 8) Anti nuisance logics incorporated as per internationalnorms. 9) Separate two relays for UP and DOWN command fordriveinterfacing. 10) DooropenandDoorcloserelaysseperate. 11) Auto door / Manual door selection in controller card. 12) Dooropentimesiteselectable. 13) RunTimerintroduced. 14) Anti-creep input added in software for hydraulic controller. 15) Emergencystopinputavailable. 16) LowcostDuplexcontrolleravailable. OGEN 2 OGEN 1 NGLC- V3F Lift Controller : For Geared Motor-AutoDoor/ManualDoor OMKAR ELECTRONICSAN ISO 9001:2008 company NAIC-CRISIL SE 3B JAS-ANZ Regd. Office & Works : Plot No. K-3, Udyog Bhavan 2, “A” Wing, F-7, 1st Floor, Additional Ambernath, MIDC, Anand Nagar, Ambernath (E) - 421 506. Dist. Thane, Maharashtra State. INDIA. Tel No.: 0251-2621040 OMKARELECTRONICSELECTRONICS Email : sale.omkar@yahoo.com / omkar_electronics@ymail.com Website : omkarelectronics.net
  • 7. ARD Controller (Universal) – Auto Door & Manual Door TO CONTROL IT TO NEW LEVELS OF EXCELLENCE FEATURES – 1) Can be interfaced with any controller either single speed or V3F. 2) Only safety chain of main controller needs to be routed from this controller. 3) Terminal limit switches of main controller can also be interfaced optionally. 4) Inclusive with battery and battery charger. 5) Motor supply, brake, Retiring Cam and auto door supply are connected parallel to existing supply and becomes active only duringARD operation. 6) Saves battery life and improves number of starts because of current sensing. OMKARELECTRONICSELECTRONICS
  • 8. FUNCTIONING OF ARD CONTROLLER – 1) There is small adjustable delay in taking over of ARD operation after power shut down to accommodate mechanical stabilization of entire system and to protect gear box. 2) Once system stabilizes, and safety chain is detected, inverter section starts and 110vdc is generated to activate R Cam. 3) Then motor rotates once clockwise and once anti-clockwise and compares current in both directions. And continues to run in the direction where current consumption is low to save batteries. ARD Controller (Universal) – Auto Door & Manual Door OMKAR ELECTRONICSAN ISO 9001:2008 company NAIC-CRISIL SE 3B JAS-ANZ Regd. Office & Works : Plot No. K-3, Udyog Bhavan 2, “A” Wing, F-7, 1st Floor, Additional Ambernath, MIDC, Anand Nagar, Ambernath (E) - 421 506. Dist. Thane, Maharashtra State. INDIA. Tel No.: 0251-2621040 OMKARELECTRONICSELECTRONICS Email : sale.omkar@yahoo.com / omkar_electronics@ymail.com Website : omkarelectronics.net
  • 9. NGLC – MRL – Geared OR Gearless Features of MRL controller • Full collective, G+10. • Only external UPS is required as ARD, all other switchgear is inbuilt. • 7 segment common anode display output. • LCD display to show shaft faults, car gate – landing gate – limit switches position – current position and destination of car, all pending calls, etc. • Single wire registration i.e. only one off wire from button. • Counting type car top reeds – Only two reeds, one for up direction slowing and second for down direction slowing and two more reeds, one for up direction stopping and second for down direction stopping. • 16 digit alphanumeric password for counter for lift stopping after defined predetermined time, e.g. one day, one week, one month or two months, etc. • On board optical isolation from field wiring. • Three stage safety chain for customer, avoiding accidental shorting of safeties by trainee technician. In no condition a technician can short entire safety of lift. • Car gate and landing gate voltage 110v. • There are six limit switches – three on top floor and three on Ground floor.All limit switches are 110, for reliable intended TO CONTROL SPEED TO THE HIGHEST LEVEL OMKARELECTRONICSELECTRONICS
  • 10. operation. Reed switches are not allowed in place of limit switches, according to Bombay Lift rules. • All limit switches are NC according to Bombay Lift Rules. • Output contactor for motor, for isolating motor from source, according to Bombay Lift Rules. • Extra brake relay in PCB to take care of drive becoming faulty. In any case is drive hangs or becomes non- responsive during running, this relay comes in picture and avoids accident. • DOB, Auto Fan, Auto / Manual doors relays are also available on-board. • Floor setting is field settable. NGLC – MRL – Geared OR Gearless OMKAR ELECTRONICSAN ISO 9001:2008 company NAIC-CRISIL SE 3B JAS-ANZ Regd. Office & Works : Plot No. K-3, Udyog Bhavan 2, “A” Wing, F-7, 1st Floor, Additional Ambernath, MIDC, Anand Nagar, Ambernath (E) - 421 506. Dist. Thane, Maharashtra State. INDIA. Tel No.: 0251-2621040 OMKARELECTRONICSELECTRONICS Email : sale.omkar@yahoo.com / omkar_electronics@ymail.com Website : omkarelectronics.net
  • 11. NGLC - Hydraulic Controllers up to G+7 Features of Hydraulic elevator controller • State-of-art design with Low voltage and High voltage separation in PCB layout. • 7 segment common anode display output. • LCD display to show shaft faults, car gate – landing gate – limit switches position – current position and destination of car, all pending calls, etc. • Single wire registration i.e. only one off wire from button. • Counting type car top reeds – Only two reeds, one for up direction slowing and second for down direction slowing and two more reeds, one for up direction stopping and second for down direction stopping. • 16 digit alphanumeric password for counter for lift stopping after defined predetermined time, e.g. one day, one week, one month or two months, etc. • On board optical isolation from field wiring. • Anti-creep input available. • Three stage safety chain for customer, avoiding accidental shorting of safeties by trainee technician. • Car gate and landing gate voltage 110v. TO CONTROL TOUCH FOR BETTER EXPERIENCE LEVEL OMKARELECTRONICSELECTRONICS
  • 12. • There are six limit switches – three on top floor and three on Ground floor. All limit switches are 110, for reliable intended operation. Reed switches are not allowed in place of limit switches, according to Bombay Lift rules. • All limit switches are NC according to Bombay Lift Rules. • Output contactor for motor, for isolating motor from source, according to Bombay Lift Rules. • Separate R-cam contactor for New type locks. • As all components are of SMD technology, life of components increases because of reduced oxidation of contact and junctions. • DOB, Auto Fan, Auto / Manual doors relays are also available on-board. • Floor setting is field settable. NGLC - Hydraulic Controllers up to G+7 OMKAR ELECTRONICSAN ISO 9001:2008 company NAIC-CRISIL SE 3B JAS-ANZ Regd. Office & Works : Plot No. K-3, Udyog Bhavan 2, “A” Wing, F-7, 1st Floor, Additional Ambernath, MIDC, Anand Nagar, Ambernath (E) - 421 506. Dist. Thane, Maharashtra State. INDIA. Tel No.: 0251-2621040 OMKARELECTRONICSELECTRONICS Email : sale.omkar@yahoo.com / omkar_electronics@ymail.com Website : omkarelectronics.net
  • 13. TO CONTROL THE BEST OUT OF OTHER Home Lift Controller - Gearless Motor Features of Home elevator controller • Works on only single phase supply, hence suitable for home installation. • Cost of ARD also reduces as only single ph UPS works as ARD. • Down collective, G+7 • 7 segment common anode display output. • LCD display to show shaft faults, car gate – landing gate – limit switches position – current position and destination of car, all pending calls, etc. • Single wire registration i.e. only one off wire from button. • Counting type car top reeds – Only two reeds, one for up direction slowing and second for down direction slowing and two more reeds, one for up direction stopping and second for down direction stopping. • 16 digit alphanumeric password for counter for lift stopping after defined predetermined time, e.g. one day, one week, one month or two months, etc. • On board optical isolation from field wiring. OMKARELECTRONICSELECTRONICS
  • 14. • Three stage safety chain for customer, avoiding accidental shorting of safeties by trainee technician. In no condition a technician can short entire safety of lift. • Car gate and landing gate voltage 12v. • There are six limit switches – three on top floor and three on ground floor. All limit switches are 110, for reliable intended operation. Reed switches are not allowed in place of limit switches, according to Bombay Lift rules. • All limit switches are NC according to Bombay Lift Rules. • Output contactor for motor, for isolating motor from source, according to Bombay Lift Rules. • Extra brake relay in PCB to take care of drive becoming faulty. In any case if drive hangs or becomes non- responsive during running, this relay comes in picture and avoids accident. • DOB, Auto Fan, Auto / Manual doors relays are also available on-board. • Floor setting is field settable. Home Lift Controller - Gearless Motor OMKAR ELECTRONICSAN ISO 9001:2008 company NAIC-CRISIL SE 3B JAS-ANZ Regd. Office & Works : Plot No. K-3, Udyog Bhavan 2, “A” Wing, F-7, 1st Floor, Additional Ambernath, MIDC, Anand Nagar, Ambernath (E) - 421 506. Dist. Thane, Maharashtra State. INDIA. Tel No.: 0251-2621040 OMKARELECTRONICSELECTRONICS Email : sale.omkar@yahoo.com / omkar_electronics@ymail.com Website : omkarelectronics.net
  • 15. 0.75 sq. mm 4 core Round or Flat Wire Harness Wire harness costing will depend on floor heights and other options, it will be quoted time to time. Travelling cable – # Wire rates are volatile and depend on fluctuations of copper and pvc prices hence kindly enquire at the time of ordering. # Our wire is ISI approved. Round or Flat0.5 sq. mm 0.75 sq. mm 0.5 sq. mm 12 core 12 core 6 core Round or Flat Round or Flat Single Core Wire 0.5 sq. mm 0.75 sq. mm 1 sq. mm 1.5 sq. mm 2 sq. mm 4 sq. mm Advantages of Harness – 1. Time required to do wiring reduces from 6 man-days to half man-day. 2. Wiring Error possibilities are reduced to zero. 3. No wastage or theft of costly wires. 4. No necessity of Expert Engineer for wiring of that particular controller. 5. Maintenance of lift becomes easy as every wire has ferrule to denominate the signal. A engineer sitting in office can direct and solve site problems by technicians, without visiting site. 6. As every contact has copper lugs, life of installation increases by reducing oxidation of contacts. 7. Man power retention cost incurred in maintaining expert people in organisation reduces drastically. 8. Inventory reduces to zero and Just-in-time technique is employed by user along with Just-as-required. No wire need to be purchased extra. OMKARELECTRONICSELECTRONICS
  • 16. Accessories OMKAR ELECTRONICSAN ISO 9001:2008 company NAIC-CRISIL SE 3B JAS-ANZ Regd. Office & Works : Plot No. K-3, Udyog Bhavan 2, “A” Wing, F-7, 1st Floor, Additional Ambernath, MIDC, Anand Nagar, Ambernath (E) - 421 506. Dist. Thane, Maharashtra State. INDIA. Tel No.: 0251-2621040 1) Controller card for NGLC- Single Speed up to G+7 with LCD 2) Controller card for NGLC - V3F up to G+7 with LCD 3) Controller card for NGLC - G+15 Dn coll / G+10 Full coll with LCD 4) Reed s/w TVS make tubular (pencil type) 5) DOB 6) ‘U’ type Magnetic shoe for door zone 7) Fins (Cam) for Magnetic shoe mounting arrangement for auto door 8) Magnets 10) Heavy Duty Junction box set – includes junction box – 2 nos, maintenance box – 1 no, motor wire (7/20) – 50 yards, Beeper – 1 no, Lugs for motor – 9 nos. OMKARELECTRONICSELECTRONICS Email : sale.omkar@yahoo.com / omkar_electronics@ymail.com Website : omkarelectronics.net 9) Voice announcement systems up to G+15 with continuous music