4. Date of last change Reference/Name of Presentation/SN 4
EPCF description
Complete FIP network architecture
Complete FIP network architecture
I/O rack I/O rack
I/O rack
I/O rack I/O rack
I/O rack I/O rack
I/O rack
I/O rack I/O rack
I/O rack
I/O rack I/O rack
I/O rack I/O rack
common
I/O
Train 4
Train 5
Train 6
FIP network architecture
common
I/O
common
I/O
common
I/O
common
I/O
common
I/O
standby PLC
normal PLC
standby PLC
normal PLC
standby PLC
normal PLC
I/O rack I/O rack
common
I/O
common
I/O
5. Date of last change Reference/Name of Presentation/SN 5
EPCF description
Complete Ethernet network architecture
Complete Ethernet network architecture
Supervisor
LCI
SW SW
Supervisor
LCI
SW SW
Supervisor
LCI
SW SW
Train 4 Train 5
Train 6
Ethernet network architecture
optical ring
SW switch
C3 machine
exitation
MR machine
excitation
standby PLC
normal PLC
C3 machine
exitation
MR machine
excitation
standby PLC
normal PLC
C3 machine
exitation
MR machine
excitation
standby PLC
normal PLC
6. Date of last change Reference/Name of Presentation/SN 6
EPCF description
Normal configuration
Normal configuration
Jacking oil, low voltage CB
train 4 Auxiliaries+MCC
50/60 Hz frequency
converter
train 4 LCI
C3 m otor variable
speed excitation
control
train 4 C3 exciter
MR m otor variable
speed excitation
control
train 4 MR exciter
60 Hz Protection and
Control
train 4 EPCF
orders
start/
stop
status/
faults
status
faults
orders
status/faults
MR Gas Turbine
control
train 4 MR m ark VI
C3 Gas Turbine
control
train 4 C3 m ark VI
status/faults 60 Hz
Circuit Breaker
and
synchronisers
train 4 10 kV switchgear
orders
status/
faults
status/
faults
status/
faults
orders
orders orders
orders
MS MS
External cooler
train 4 LCI
50/60 Hz Transform ers
train 4 LCI
50 Hz
Circuit Breaker
33 kV switchgear
status/faults
orders
DCS system
m aster
Custom er
status/faults
orders
pressures
levels
tem peratures
serial link RS485 m odbus RTU
synchronisation signals
synchronisation signals
ENMC system
Custom er
status/faults
7. Date of last change Reference/Name of Presentation/SN 7
EPCF description
Degraded configuration
Degraded configuration
Jacking oil, low voltage CB
train 4 Auxiliaries+MCC
50/60 Hz frequency
converter
train 5 LCI
C3 m otor variable
speed excitation
control
train 4 C3 exciter
MR m otor variable
speed excitation
control
train 4 MR exciter
60 Hz Protection and
Control
train 5 EPCF
orders
start/
stop
status/
faults
status
faults
orders
status/faults
MR Gas Turbine
control
train 4 MR m ark VI
C3 Gas Turbine
control
train 4 C3 m ark VI
status/faults 60 Hz
Circuit Breaker
and
synchronisers
train 4 10 kV switchgear
orders
status/
faults
status/
faults
status/
faults
orders
orders orders
orders
MS MS
External cooler
train 5 LCI
50/60 Hz Transform ers
train 5 LCI
50 Hz
Circuit Breaker
33 kV switchgear
status/faults
orders
DCS system
m aster
Custom er
status/faults
orders
pressures
levels
tem peratures
serial link RS485 m odbus RTU
synchronisation signals
synchronisation signals
ENMC system
Custom er
status/faults
13. Date of last change Reference/Name of Presentation/SN 13
EPCF description
Menu view
Menu view
14. Date of last change Reference/Name of Presentation/SN 14
EPCF description
General diagram
General diagram
15. Date of last change Reference/Name of Presentation/SN 15
EPCF description
Train detail diagram
Train detail diagram
16. Date of last change Reference/Name of Presentation/SN 16
EPCF description
LCI fault detail view
LCI fault detail view
17. Date of last change Reference/Name of Presentation/SN 17
EPCF description
Symbols and inset
Symbols and inset
Tag of Equipment
Inset indicator Red rectangle means at least one alarm
18. Date of last change Reference/Name of Presentation/SN 18
EPCF description
Alarm view
Alarm view
19. Date of last change Reference/Name of Presentation/SN 19
EPCF description
Events view
Events view
20. Date of last change Reference/Name of Presentation/SN 20
EPCF description
Trends view
Trends view
21. Date of last change Reference/Name of Presentation/SN 21
EPCF description
System view
System view