SlideShare a Scribd company logo
R
DIXSON
071-40208C
Application
AMETEK Dixson bargraphs are appropriate in any application
where moving pointer meters have been used in the past, and
in applications where greater accuracy, readability, and reliabil-
ity are desirable. Signal sensitivities span ANSI C39.1 ranges, all
conventional current loops, and voltage control signals. An op-
tional RS-422 serial data bus allows for distributed control sys-
tem applications. The instruments are suitable for local or
remote, primary or redundant system indication.
The BB101P enclosure is form-factor compatible with stan-
dard, 6-inch edgewise switchboard instruments and is a direct
replacement for the GE/Yokogawa 180, International Sigma
Model 1151/1251, Westinghouse/Weschler VX252, and the
Modutech and Crompton 6-inch meters. This simplifies retrofit
into existing systems without panel modifications.
For control applications, the optional set point relay module
provides on/off and differential gap control and annunciation
using three set points. The optional digital display reads to 10
percent over- and underrange.
An optional temperature measurement module makes the in-
strument a direct-reading indicator for E, J, K, and T thermo-
couples or 100-ohm RTD, and an optional retransmission
module simplifies distribution of the temperature parameter
throughout the system.
User-programmability provides maximum versatility and mini-
mizes the need for spares. A solid-state design with no moving
parts yields a highly reliable product, especially under condi-
tions of shock, vibration, dust and moisture. Features such as
linearization, sensor power, retransmission, and min/max readings
make the “PRO” Series the ideal choice for your application.
BB101P Programmable Bargraph
(Class III-Commercial/Industrial Grade)
Features
• Brilliant red LED display for excellent visibility
• Minimum 88,000-hour MTBF
• Rugged—high resistance to vibration and shock
• Microprocessor-based design
• Programmable configuration using front panel switches or
PC serial link
• Available with or without program switches on front
• Input signal ranges switch-selectable
• Auto-calibration algorithm
• Linearization of input signals
• Min/max signal memory (peak/valley hold)
• Universal 6-inch rectilinear form interchangeable with all
major manufacturers and panel cutouts
• Front panel mounting
• Underrange/overrange indication
• Modular design for flexibility and options
Options
• Digital display with true minus-sign indication
• Green or amber LEDs
• On/off control using three set point relays
• Direct temperature measurement
• Auxiliary transducer power supply
• Two-wire, isolated retransmission
A
METEK Dixson “PRO” (PROgrammable) Series
bargraphs are the preferred choice for new appli-
cations, or for replacement of switchboard meters,
other common size indicators, and set point controllers.
The “PRO” Series is feature-enhanced, and options are
available to solve most common application problems.
These models are easily configurable for maximum flexi-
bility. Nuclear-qualified versions are also available (see
data sheet P/N 071-40216).
• GE/Yokogawa 180
• Sigma 1151/1251
• Westinghouse/Wechler VX252
• Modutech 6-inch meters
• Crompton 6-inch meters
R
DIXSON
287 27 Road, Grand Junction, CO 81503
Phone: (970) 244-1241 • FAX: (970) 245-6267
Toll-Free:(888) 302-0639
Internet: www.ametek.com/dixson
E-mail: info.dixson@ametek.com
071-40208C
0204
Note: for ISA S67.04 and RP67.04 Part II, consult factory for models and assistance.
PHYSICAL CHARACTERISTICS
Number of bargraph segments 101
Resolution 1.0%
ENCLOSURE MATERIAL Non-glare black Noryl or ABS case
complying with UL94 V-0 or V-1
DIGITAL DISPLAY OPTION (True minus sign) –9999 to 9999
Number of digits 4
Resolution 0.01% ± 1 count*
ENVIRONMENTAL CHARACTERISTICS
Operating temperature range (MIL-E16400G, Class 4) 0 to +60° C
Storage temperature range –40 to +85° C
POWER REQUIREMENTS Either 115/230 VAC at 50, 60, 400 Hz
or 5, 12, 24 or 48 VDC
Line regulation ±10%
Power consumption (typical, depends upon options) 3.5/7.0 VA
SENSITIVITY RANGES (Reference ANSI C39.1 Std. Sensitivities)
STANDARD FULL SCALE INPUTS FROM ZERO
(DIP-switch selectable):
DC currents 500 µA to 50 mA
DC voltages 1 to 250 V
OPTIONAL FULL SCALE INPUTS FROM ZERO
DC currents – factory configured 50 µA to 250 mA
Plug-in modules:
RS-422 Serial Data Comm.
DC voltages 50 mV to <1000 mV
AC currents 1 mA to 1000 mA; 5 A
AC voltages 250 mV to 250 V
Thermocouple - Type E –100 to +1000° C
Thermocouple - Type J –18 to +760° C
Thermocouple - Type K –18 to +1370° C
Thermocouple - Type T –160 to +400° C
RTD (100-ohm platinum) –200 to +850° C
BB101P Specifications
DC INPUT PARAMETERS
Linearity 0.02% of span ± 1 count*
Accuracy 0.04% of span ± 1 count*†
Zero stability <0.01% per °C
Gain stability <0.02% per °C
Input impedance:
For voltage inputs >200 k ohms
For 4 to 20 mADC current inputs 100-ohm compliance resistor
For 10 to 50 mADC current inputs 40-ohm compliance resistor
For all other current inputs Consult factory
Response time (typical) 175 ms
Overload (signal) 200% or 250 VDC maximum
AC INPUT PARAMETERS (true RMS-reading)
Linearity 0.4% of span **
Accuracy 0.5% of span **
Zero stability <0.04% per °C
Gain stability <0.04% per °C
Input impedance for voltage inputs >200 k ohms
Response time (typical) 325 ms
Overload (signal) 200% or 250 VAC maximum
SET POINT OPTION (internal module)
Standard set points LO and HI
Configurable alarm HI/HI (default) or LO/LO
Setability 0.1%
Hysteresis 1.0%
Relay response time (typical):
For DC inputs 350 ms
For AC inputs 650 ms
Relay contact ratings (three Form C): 0.4 A at 125 VAC
2 A at 30 VDC
RETRANSMISSION ACCURACY (4 to 20 mA) ± 0.1%
LINEARIZATION
8th
-order polynomial (nine terms). Refer to “PRO” Series Interface Kit.
* 1 count is defined as a ± unit value change of the right-most digit.
† Call factory for thermocouple, RTD, and square root input accuracy information.
** Except for first 5% of span.
BB101P Dimensions

More Related Content

PDF
Digital Vortex Flowmeters From Yokogawa
PDF
New Thermal Mass Flow Meter From Fox Instruments
PDF
Variable Area Flow Meter - SeeFlo
PDF
Flowphant t dtt31, dtt35 endress+hauser datasheet-flow switch
PDF
Current To Pneumatic Converter for Process Control
PDF
CUM223 253 endress+hauser datasheet-turbidity and suspended solids transmitter
PDF
Liquicontrol cdc80 endress+hauser datasheet
PDF
Indumax cls50 d endress+hauser datasheet-inductive conductivity sensor
Digital Vortex Flowmeters From Yokogawa
New Thermal Mass Flow Meter From Fox Instruments
Variable Area Flow Meter - SeeFlo
Flowphant t dtt31, dtt35 endress+hauser datasheet-flow switch
Current To Pneumatic Converter for Process Control
CUM223 253 endress+hauser datasheet-turbidity and suspended solids transmitter
Liquicontrol cdc80 endress+hauser datasheet
Indumax cls50 d endress+hauser datasheet-inductive conductivity sensor

What's hot (20)

PDF
Metal Tube Variable Area Flow Meter
PDF
Pump Protection Using Thermal Dispersion Switches
PDF
Memograph m rsg 40 endress+hauser datasheet-record, visualize, analyze and co...
PDF
Liquisys m ccm223 ccm253 endress+hauser datasheet-chlorine transmitter
PDF
Turbine flow meters for gas service from Hoffer
PDF
GE Advanced Modular Calibrator for Process Measurement Instruments
PDF
Thermal dispersion switch for flow, level, interface, or temperature
PDF
Liquisys m clm223 253 endress+hauser datasheet-conductivity-resistivity measu...
PDF
Orbisint cps11 cps11 d-endress+hauser datasheet-ph electrodes
PDF
Flowfit cca250 endress+hauser datasheet-flow assembly for chlorine and p h:or...
PDF
Fluke Data Acquisition System Selection Guide. Hubungi PT. Siwali Swantika 02...
PDF
Liquiline system ca80 no endress+hauser datasheet-colorimetric analyzer for n...
PPTX
Sm electronics services exhbit. ppt
PDF
Thermal Dispersion Mass Flow Measurement
PDF
Thermal Mass Flow Meter for Oil & Gas Applications
PDF
Ins and Outs of I/P Transducers
PDF
Toshniwal - Thermal mass flow meters and controller
PDF
Thermal Mass Flow Meters Reduce Energy Costs and Enhance Emissions Monitoring
PPTX
Siemens Air velocity sensor
PDF
Liquid Level Measurement Using the Bubbler Method
Metal Tube Variable Area Flow Meter
Pump Protection Using Thermal Dispersion Switches
Memograph m rsg 40 endress+hauser datasheet-record, visualize, analyze and co...
Liquisys m ccm223 ccm253 endress+hauser datasheet-chlorine transmitter
Turbine flow meters for gas service from Hoffer
GE Advanced Modular Calibrator for Process Measurement Instruments
Thermal dispersion switch for flow, level, interface, or temperature
Liquisys m clm223 253 endress+hauser datasheet-conductivity-resistivity measu...
Orbisint cps11 cps11 d-endress+hauser datasheet-ph electrodes
Flowfit cca250 endress+hauser datasheet-flow assembly for chlorine and p h:or...
Fluke Data Acquisition System Selection Guide. Hubungi PT. Siwali Swantika 02...
Liquiline system ca80 no endress+hauser datasheet-colorimetric analyzer for n...
Sm electronics services exhbit. ppt
Thermal Dispersion Mass Flow Measurement
Thermal Mass Flow Meter for Oil & Gas Applications
Ins and Outs of I/P Transducers
Toshniwal - Thermal mass flow meters and controller
Thermal Mass Flow Meters Reduce Energy Costs and Enhance Emissions Monitoring
Siemens Air velocity sensor
Liquid Level Measurement Using the Bubbler Method
Ad

Similar to Process Digital Bargraph Display for Industrial Control and Automation (20)

PDF
Yokogawa DX2000 DAQSTATION
PDF
Data Acquisition Equipment for Automation and Process Control
PDF
HB-8215 & HB-8216
PPT
Solution on Portable Blood Pressure Monitor System
PDF
2301 manual (v7.0 - 80384 a) (1) gefran
PPT
Greystone product
DOC
8246 a specification- www.ttbvs.com
PPT
Handheld Infrared Thermometer
PDF
Head Mounted Temperature Transmitter
PDF
HX Controlador temperatura Hanyoung NUX (www.nammisa.com)
PDF
6000C Universal input of color paperless recorder
PDF
ADCMT 7352 Series Digital Multimeter
PDF
4351 e hightempthermaldetector
PDF
ATIs-D12-Digital-Gas-Transmitter.pdf
PPT
EEP-EnOcean Profiles v02.00
PPT
EEP-EnOcean Profiles v02.00
Yokogawa DX2000 DAQSTATION
Data Acquisition Equipment for Automation and Process Control
HB-8215 & HB-8216
Solution on Portable Blood Pressure Monitor System
2301 manual (v7.0 - 80384 a) (1) gefran
Greystone product
8246 a specification- www.ttbvs.com
Handheld Infrared Thermometer
Head Mounted Temperature Transmitter
HX Controlador temperatura Hanyoung NUX (www.nammisa.com)
6000C Universal input of color paperless recorder
ADCMT 7352 Series Digital Multimeter
4351 e hightempthermaldetector
ATIs-D12-Digital-Gas-Transmitter.pdf
EEP-EnOcean Profiles v02.00
EEP-EnOcean Profiles v02.00
Ad

More from Classic Controls, Inc. (20)

PDF
Magnetic Level Indicators (MLIs) and Bridle Combination Units
PDF
Drying Compressed Air In Hazardous Atmospheres
PDF
Signal Fire Wireless Telemetry Catalog
PDF
Compressed Coalescing Filters for Industrial Use
PDF
Blunt Rod Lightning Protection Comparison
PDF
Ultrasonic Gas Flow Measurement
PDF
Segmented Ball Control Valve for Natural Gas Operations
PDF
Resilient Seated Butterfly Valves
PDF
Nitrogen Generator Systems for Industrial Applications
PDF
Yokogawa CENTUM VP Process Control and Automation Platform
PDF
Electro-Hydraulic Damper Drives for Combustion Control
PDF
Fuel Air Ratio Controller for Combustion Efficiency
PDF
PMV Digital Valve Positioner
PDF
GE Consolidated Pressure Relief and Safety Valves
PDF
Scenarios for Specifying an Uninterruptible Power Supply for Industrial Appli...
PDF
Stainless Steel Cast NAMUR Mounting Bracket
PDF
Pressure Measurement Handbook for Process Control
PDF
Electro-Hydraulic Linear Actuators for Industrial Valves
PDF
Energy Calculator for Usage Monitoring
PDF
Pressure Regulating Valve - Type G-4 Cash Valve
Magnetic Level Indicators (MLIs) and Bridle Combination Units
Drying Compressed Air In Hazardous Atmospheres
Signal Fire Wireless Telemetry Catalog
Compressed Coalescing Filters for Industrial Use
Blunt Rod Lightning Protection Comparison
Ultrasonic Gas Flow Measurement
Segmented Ball Control Valve for Natural Gas Operations
Resilient Seated Butterfly Valves
Nitrogen Generator Systems for Industrial Applications
Yokogawa CENTUM VP Process Control and Automation Platform
Electro-Hydraulic Damper Drives for Combustion Control
Fuel Air Ratio Controller for Combustion Efficiency
PMV Digital Valve Positioner
GE Consolidated Pressure Relief and Safety Valves
Scenarios for Specifying an Uninterruptible Power Supply for Industrial Appli...
Stainless Steel Cast NAMUR Mounting Bracket
Pressure Measurement Handbook for Process Control
Electro-Hydraulic Linear Actuators for Industrial Valves
Energy Calculator for Usage Monitoring
Pressure Regulating Valve - Type G-4 Cash Valve

Recently uploaded (20)

PPTX
M Tech Sem 1 Civil Engineering Environmental Sciences.pptx
PPTX
Fundamentals of safety and accident prevention -final (1).pptx
PPTX
Infosys Presentation by1.Riyan Bagwan 2.Samadhan Naiknavare 3.Gaurav Shinde 4...
PDF
737-MAX_SRG.pdf student reference guides
PPTX
Current and future trends in Computer Vision.pptx
PDF
BMEC211 - INTRODUCTION TO MECHATRONICS-1.pdf
PDF
R24 SURVEYING LAB MANUAL for civil enggi
PDF
PREDICTION OF DIABETES FROM ELECTRONIC HEALTH RECORDS
PDF
Operating System & Kernel Study Guide-1 - converted.pdf
PDF
III.4.1.2_The_Space_Environment.p pdffdf
PDF
keyrequirementskkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk
PDF
composite construction of structures.pdf
PPTX
bas. eng. economics group 4 presentation 1.pptx
PDF
Human-AI Collaboration: Balancing Agentic AI and Autonomy in Hybrid Systems
DOCX
573137875-Attendance-Management-System-original
PPTX
Geodesy 1.pptx...............................................
PPTX
FINAL REVIEW FOR COPD DIANOSIS FOR PULMONARY DISEASE.pptx
PDF
Evaluating the Democratization of the Turkish Armed Forces from a Normative P...
PDF
PPT on Performance Review to get promotions
PDF
SM_6th-Sem__Cse_Internet-of-Things.pdf IOT
M Tech Sem 1 Civil Engineering Environmental Sciences.pptx
Fundamentals of safety and accident prevention -final (1).pptx
Infosys Presentation by1.Riyan Bagwan 2.Samadhan Naiknavare 3.Gaurav Shinde 4...
737-MAX_SRG.pdf student reference guides
Current and future trends in Computer Vision.pptx
BMEC211 - INTRODUCTION TO MECHATRONICS-1.pdf
R24 SURVEYING LAB MANUAL for civil enggi
PREDICTION OF DIABETES FROM ELECTRONIC HEALTH RECORDS
Operating System & Kernel Study Guide-1 - converted.pdf
III.4.1.2_The_Space_Environment.p pdffdf
keyrequirementskkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk
composite construction of structures.pdf
bas. eng. economics group 4 presentation 1.pptx
Human-AI Collaboration: Balancing Agentic AI and Autonomy in Hybrid Systems
573137875-Attendance-Management-System-original
Geodesy 1.pptx...............................................
FINAL REVIEW FOR COPD DIANOSIS FOR PULMONARY DISEASE.pptx
Evaluating the Democratization of the Turkish Armed Forces from a Normative P...
PPT on Performance Review to get promotions
SM_6th-Sem__Cse_Internet-of-Things.pdf IOT

Process Digital Bargraph Display for Industrial Control and Automation

  • 1. R DIXSON 071-40208C Application AMETEK Dixson bargraphs are appropriate in any application where moving pointer meters have been used in the past, and in applications where greater accuracy, readability, and reliabil- ity are desirable. Signal sensitivities span ANSI C39.1 ranges, all conventional current loops, and voltage control signals. An op- tional RS-422 serial data bus allows for distributed control sys- tem applications. The instruments are suitable for local or remote, primary or redundant system indication. The BB101P enclosure is form-factor compatible with stan- dard, 6-inch edgewise switchboard instruments and is a direct replacement for the GE/Yokogawa 180, International Sigma Model 1151/1251, Westinghouse/Weschler VX252, and the Modutech and Crompton 6-inch meters. This simplifies retrofit into existing systems without panel modifications. For control applications, the optional set point relay module provides on/off and differential gap control and annunciation using three set points. The optional digital display reads to 10 percent over- and underrange. An optional temperature measurement module makes the in- strument a direct-reading indicator for E, J, K, and T thermo- couples or 100-ohm RTD, and an optional retransmission module simplifies distribution of the temperature parameter throughout the system. User-programmability provides maximum versatility and mini- mizes the need for spares. A solid-state design with no moving parts yields a highly reliable product, especially under condi- tions of shock, vibration, dust and moisture. Features such as linearization, sensor power, retransmission, and min/max readings make the “PRO” Series the ideal choice for your application. BB101P Programmable Bargraph (Class III-Commercial/Industrial Grade) Features • Brilliant red LED display for excellent visibility • Minimum 88,000-hour MTBF • Rugged—high resistance to vibration and shock • Microprocessor-based design • Programmable configuration using front panel switches or PC serial link • Available with or without program switches on front • Input signal ranges switch-selectable • Auto-calibration algorithm • Linearization of input signals • Min/max signal memory (peak/valley hold) • Universal 6-inch rectilinear form interchangeable with all major manufacturers and panel cutouts • Front panel mounting • Underrange/overrange indication • Modular design for flexibility and options Options • Digital display with true minus-sign indication • Green or amber LEDs • On/off control using three set point relays • Direct temperature measurement • Auxiliary transducer power supply • Two-wire, isolated retransmission A METEK Dixson “PRO” (PROgrammable) Series bargraphs are the preferred choice for new appli- cations, or for replacement of switchboard meters, other common size indicators, and set point controllers. The “PRO” Series is feature-enhanced, and options are available to solve most common application problems. These models are easily configurable for maximum flexi- bility. Nuclear-qualified versions are also available (see data sheet P/N 071-40216). • GE/Yokogawa 180 • Sigma 1151/1251 • Westinghouse/Wechler VX252 • Modutech 6-inch meters • Crompton 6-inch meters
  • 2. R DIXSON 287 27 Road, Grand Junction, CO 81503 Phone: (970) 244-1241 • FAX: (970) 245-6267 Toll-Free:(888) 302-0639 Internet: www.ametek.com/dixson E-mail: info.dixson@ametek.com 071-40208C 0204 Note: for ISA S67.04 and RP67.04 Part II, consult factory for models and assistance. PHYSICAL CHARACTERISTICS Number of bargraph segments 101 Resolution 1.0% ENCLOSURE MATERIAL Non-glare black Noryl or ABS case complying with UL94 V-0 or V-1 DIGITAL DISPLAY OPTION (True minus sign) –9999 to 9999 Number of digits 4 Resolution 0.01% ± 1 count* ENVIRONMENTAL CHARACTERISTICS Operating temperature range (MIL-E16400G, Class 4) 0 to +60° C Storage temperature range –40 to +85° C POWER REQUIREMENTS Either 115/230 VAC at 50, 60, 400 Hz or 5, 12, 24 or 48 VDC Line regulation ±10% Power consumption (typical, depends upon options) 3.5/7.0 VA SENSITIVITY RANGES (Reference ANSI C39.1 Std. Sensitivities) STANDARD FULL SCALE INPUTS FROM ZERO (DIP-switch selectable): DC currents 500 µA to 50 mA DC voltages 1 to 250 V OPTIONAL FULL SCALE INPUTS FROM ZERO DC currents – factory configured 50 µA to 250 mA Plug-in modules: RS-422 Serial Data Comm. DC voltages 50 mV to <1000 mV AC currents 1 mA to 1000 mA; 5 A AC voltages 250 mV to 250 V Thermocouple - Type E –100 to +1000° C Thermocouple - Type J –18 to +760° C Thermocouple - Type K –18 to +1370° C Thermocouple - Type T –160 to +400° C RTD (100-ohm platinum) –200 to +850° C BB101P Specifications DC INPUT PARAMETERS Linearity 0.02% of span ± 1 count* Accuracy 0.04% of span ± 1 count*† Zero stability <0.01% per °C Gain stability <0.02% per °C Input impedance: For voltage inputs >200 k ohms For 4 to 20 mADC current inputs 100-ohm compliance resistor For 10 to 50 mADC current inputs 40-ohm compliance resistor For all other current inputs Consult factory Response time (typical) 175 ms Overload (signal) 200% or 250 VDC maximum AC INPUT PARAMETERS (true RMS-reading) Linearity 0.4% of span ** Accuracy 0.5% of span ** Zero stability <0.04% per °C Gain stability <0.04% per °C Input impedance for voltage inputs >200 k ohms Response time (typical) 325 ms Overload (signal) 200% or 250 VAC maximum SET POINT OPTION (internal module) Standard set points LO and HI Configurable alarm HI/HI (default) or LO/LO Setability 0.1% Hysteresis 1.0% Relay response time (typical): For DC inputs 350 ms For AC inputs 650 ms Relay contact ratings (three Form C): 0.4 A at 125 VAC 2 A at 30 VDC RETRANSMISSION ACCURACY (4 to 20 mA) ± 0.1% LINEARIZATION 8th -order polynomial (nine terms). Refer to “PRO” Series Interface Kit. * 1 count is defined as a ± unit value change of the right-most digit. † Call factory for thermocouple, RTD, and square root input accuracy information. ** Except for first 5% of span. BB101P Dimensions