507	Wide	Screen	Display

Model:	507WSD	-		Quick	Installa9on	Guide
Be	sure	the	monitor	has	power	and	is	powered	on.	The	on/off	buFon	is	on	the	right	side	of	the	monitor.	
NOTE:	It	is	recommended	you	program	the	sensors	before	puJng	them	on	the	valve	stems.	
CODING	SENSORS	TO	DISPLAY	
1. Push	the	“SET”	buFon	un9l	it	beeps.	You	are	now	in	the	programming	mode.	The	“HI	PRESSURE	SET”	parameter	will	blink	at
the	boFom	of	the	screen.	Push	the	(+)	buFon	and	scroll	through	the	parameters	un9l	“LEARN	ID”	appears.

2. Quickly	press	and	release	the	“SET”	buFon.	The	first	9re	on	the	display	will	blink.	If	you	want	to	program	a	different	9re,
press	the	(+)	buFon	to	move	to	the	correct	9re.	Push	the	“SET”	buFon	again	and	“FFF	FFF”	will	flash.	Put	the	sensor	for	that
9re	posi9on	next	to	the	display	and	press	the	“GO”	buFon.	The	display	will	capture	the	sensor	code	and	show	it	on	the
screen.	Again,	push	and	release	the	“SET”	buFon	to	save	the	code	to	that	posi9on.	If	a	double	beep	is	heard,	try	pressing
the	“GO”	buFon	again.	When	coded	correctly,	a	single	beep	will	be	heard	and	a	six	(6)	digit	code	will	be	shown.
3. Use	the	(+)	buFon	to	move	to	the	next	9re	posi9on	you	want	to	program.	Again,	press	the	“SET”	buFon	and	“FFF	FFF”	will
blink.	Put	the	sensor	for	that	9re	posi9on	next	to	the	display	and	press	the	“GO”	buFon	to	capture	the	sensor	code.	Press
“SET”	again	to	save.
4. When	you	are	finished	programming	all	your	sensors,	press	the	“BACK”	buFon	to	return	to	the	parameter	at	the	boFom	of
the	screen.	Use	the	(+)	or	(-)	buFons	to	scroll	to	another	parameter,	if	necessary.	If	finished	programming,	press	the	“BACK”
buFon	until you get back to the main screen. Your sensors will read "0" and the unit will alarm. Press the (+) button to
silence and continue setup.
Set	the	following	parameters	BEFORE	installing	the	sensors	onto	the	valve	stems	
PRESSURE	PARAMETERS	
To	choose	the	Pressure	Parameter,	press	the	“SET”	buFon	un9l	it	beeps.	Press	the	(+)	buFon	three	(3)	9mes	and	“SET”	will	
appear	at	the	boFom	of	the	screen	and	BAR/PSI	will	be	blinking	on	the	screen.	Press	the	“SET”	buFon	again	and	then	use	
the	(+)	buFon	to	select	“PSI”	(or	“BAR”).	Press	“SET”	again	to	select	it.	Press	“BACK”	to	go	back	to	the	Main	Screen.	
TEMPERATURE	PARAMETERS	
To	set	the	Temperature	Parameters	(F°	or	C°),	press	the	“SET”	buFon	un9l	it	beeps.	Press	the	(+)	buFon	four	(4)	9mes	and	
“SET”	will	appear	at	the	boFom	of	the	screen	and	F°/C°	will	appear	on	the	screen,	blinking.	Press	the	“SET”	buFon	again	and	
then	use	the	(+)	buFon	to	select	F°	or	C°.	Press	“SET”	again	to	select	it.	Press	“BACK”	to	go	back	to	the	Main	Screen.	
HIGH	TEMPERATURE	ALARM	
To	set	the	High	Temperature	Alarm,	press	the	“SET”	buFon	un9l	it	beeps.	Press	the	(+)	buFon	twice	and	“HI	TEMP	SET”	will	
appear.	 Again,	 press	 the	 “SET”	 buFon	 to	 enter	 that	 mode.	 Use	 the	 (+)	 or	 (-)	 buFons	 to	 adjust	 the	 High	 Temperature	
parameter,	if	desired.	Press	“SET”	to	save.	When	done	Press	the	“BACK”	buFon.	
NOTE:	We	recommend	leaving	this	temperature	seJng	at	the	default	158°	for	all	types	of	9res.		
HIGH	PRESSURE	ALARM	
To	set	up	the	High-pressure	Alarm,	press	the	“SET”	buFon	un9l	it	beeps.	“HI	PRESSURE	SET”	will	appear	at	the	boFom	of	the	
screen.	Again,	press	the	“SET”	buFon	to	enter	that	mode.	Press	the	“GO”	buFon	to	select	the	appropriate	axle.	Use	the	(+)	
or	(-)	buFons	to	adjust	the	high-pressure	alarm	20-25%	over	your	normal	9re	pressure	for	that	axle.	Press	the	“GO”	buFon	
to	move	to	the	next	axle.	When	done	seJng	each	axle	that	you	have	sensors	on,	press	the	“SET”	buFon	to	leave	that	
parameter	and	go	back	to	the	menu.	When	done,	press	the	“BACK”	buFon	to	go	to	the	Main	Screen.	
LOW	PRESSURE	ALARM	
To	set	up	the	Low-pressure	Alarm,	press	the	“SET”	buFon	un9l	it	beeps.	Press	the	(+)	buFon	once	and	“LOW	PRESSURE	SET”	
will	appear.	Again,	press	the	“SET”	buFon	to	enter	that	mode.	Press	the	“GO”	BuFon	to	select	the	appropriate	axle.	Use	the	
(+)	or	(-)	buFons	to	adjust	the	low-pressure	alarm	10%	below	your	normal	9re	pressure	for	that	axle.	Press	the	“GO”	buFon	
to	move	to	the	next	axle.	When	done	seJng	each	axle	that	you	have	sensors	on,	press	the	“SET”	buFon	to	leave	that	
parameter	and	go	back	to	the	menu.	When	done,	press	the	“BACK”	buFon	to	go	to	the	Main	Screen.	
NOTE:	If	your	9re	pressure	is	below	100	lbs.,	you	must	set	the	low-pressure	alarms	first	and	then,	when	done,	set	the	high-
pressure	alarms.	The	high	pressure	cannot	go	below	the	default	low	pressure	of	100	psi	un9l	the	low	pressure	is	reduced.		
For	further	assistance, or full kit instructions,	please	visit	our	website	at	www.TSTtruck.com, or call us at 770.889-9102.
TST-Doc-507-D-C QI-(A)

More Related Content

DOCX
Group Study Technology Instructions
PDF
Tst doc-507 ft-rv-c-manual-_a_
PPT
PDF
42 windows-10-hotkeys
PPT
Cheetah android instructions
PDF
How to use the DVB-T Box www.autocardvdgps.com
PPTX
Quick guide to using Samsung S8003 for Ko
PDF
G1manual
Group Study Technology Instructions
Tst doc-507 ft-rv-c-manual-_a_
42 windows-10-hotkeys
Cheetah android instructions
How to use the DVB-T Box www.autocardvdgps.com
Quick guide to using Samsung S8003 for Ko
G1manual

What's hot (10)

PDF
Fiat Stilo Connect Nav+ GPS GSM hidden diagnostic menu
PPT
Ubuntu phone - future of smart phones
PDF
Sky News HD Production Gallery
DOC
8. the helicopter game
PDF
Mx management center user guide v2
PDF
Instagram - making videos
PPTX
Mx management center user guide v2
DOCX
MOZA Lite Camera Stabilizer Set Up Instructions
PDF
Shortcut keys-for-windows-10-www.penajam
Fiat Stilo Connect Nav+ GPS GSM hidden diagnostic menu
Ubuntu phone - future of smart phones
Sky News HD Production Gallery
8. the helicopter game
Mx management center user guide v2
Instagram - making videos
Mx management center user guide v2
MOZA Lite Camera Stabilizer Set Up Instructions
Shortcut keys-for-windows-10-www.penajam
Ad

Recently uploaded (20)

PPT
ACCOMPLISHMENT REPOERTS AND FILE OF GRADE 12 2021.ppt
PDF
EC290C NL EC290CNL Volvo excavator specs.pdf
PPTX
UNIT-2(B) Organisavtional Appraisal.pptx
PDF
LB85 New Holland Service Repair Manual.pdf
PDF
Volvo EC17C Compact Excavator Service Repair Manual Instant Download.pdf
PPTX
Intro to ISO 9001 2015.pptx for awareness
PPTX
Cloud_Computing_ppt[1].pptx132EQ342RRRRR1
PDF
LB95 New Holland Service Repair Manual.pdf
PPTX
Small Fleets, Big Change: Market Acceleration by Niki Okuk
PDF
Volvo EC290C NL EC290CNL engine Manual.pdf
PDF
Caterpillar Cat 324E LN Excavator (Prefix LDG) Service Repair Manual Instant ...
PPTX
Culture by Design.pptxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
PDF
book-slidefsdljflsk fdslkfjslf sflgs.pdf
PPTX
Small Fleets, Big Change: Overcoming Obstacles in the Transition to MHD Elect...
PPTX
Robot_ppt_YRG[1] [Read-Only]bestppt.pptx
PPTX
368455847-Relibility RJS-Relibility-PPT-1.pptx
PDF
Life Cycle Analysis of Electric and Internal Combustion Engine Vehicles
PDF
Journal Meraj.pdfuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuu
PDF
RPL-ASDC PPT PROGRAM NSDC GOVT SKILLS INDIA
PPTX
description of motor equipments and its process.pptx
ACCOMPLISHMENT REPOERTS AND FILE OF GRADE 12 2021.ppt
EC290C NL EC290CNL Volvo excavator specs.pdf
UNIT-2(B) Organisavtional Appraisal.pptx
LB85 New Holland Service Repair Manual.pdf
Volvo EC17C Compact Excavator Service Repair Manual Instant Download.pdf
Intro to ISO 9001 2015.pptx for awareness
Cloud_Computing_ppt[1].pptx132EQ342RRRRR1
LB95 New Holland Service Repair Manual.pdf
Small Fleets, Big Change: Market Acceleration by Niki Okuk
Volvo EC290C NL EC290CNL engine Manual.pdf
Caterpillar Cat 324E LN Excavator (Prefix LDG) Service Repair Manual Instant ...
Culture by Design.pptxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
book-slidefsdljflsk fdslkfjslf sflgs.pdf
Small Fleets, Big Change: Overcoming Obstacles in the Transition to MHD Elect...
Robot_ppt_YRG[1] [Read-Only]bestppt.pptx
368455847-Relibility RJS-Relibility-PPT-1.pptx
Life Cycle Analysis of Electric and Internal Combustion Engine Vehicles
Journal Meraj.pdfuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuu
RPL-ASDC PPT PROGRAM NSDC GOVT SKILLS INDIA
description of motor equipments and its process.pptx
Ad

Quick install guide wide screen display