ibm.com/redbooks Redpaper
Front cover
IBM Power 720 and 740
Technical Overview and Introduction
An Ding Chen
James Cruickshank
Carlo Costantini
Volker Haug
Cesar Diniz Maciel
John T Schmidt
Features the POWER7 processor providing
advanced multi-core technology
Reducedpowerrequirementswith
power-saving functions
Describes leading midrange
performance
Redbook overview and introduction 8670-61x
International Technical Support Organization
IBM Power 720 and 740: Technical Overview and
Introduction
November 2010
REDP-4637-00
© Copyright International Business Machines Corporation 2010. All rights reserved.
Note to U.S. Government Users Restricted Rights -- Use, duplication or disclosure restricted by GSA ADP Schedule
Contract with IBM Corp.
First Edition (November 2010)
This edition applies to the IBM Power 720 (8202-E4B) and Power 740 (8205-E6B) Power Systems servers.
This document created or updated on December 3, 2012.
Note: Before using this information and the product it supports, read the information in “Notices” on
page vii.
© Copyright IBM Corp. 2010. All rights reserved. iii
Contents
Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Trademarks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii
Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
The team who wrote this paper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
Now you can become a published author, too! . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xi
Comments welcome. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xi
Stay connected to IBM Redbooks publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xii
Chapter 1. General description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.1 Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.1.1 The Power 720 server. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.1.2 The Power 740 server. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.2 Operating environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.3 Physical package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.3.1 Tower model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.3.2 Rack-mount model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.4 System features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.4.1 Power 720 system features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.4.2 Power 740 system features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.4.3 Minimum features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.4.4 Power supply features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.4.5 Processor module features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.4.6 Memory features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.5 Disk and media features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
1.6 I/O drawers for Power 720 and Power 740 servers . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
1.6.1 12X I/O Drawer PCIe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
1.6.2 PCI-X DDR 12X Expansion Drawer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
1.6.3 PCI-X DDR 12X Expansion Drawer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
1.6.4 I/O drawers and usable PCI slot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
1.6.5 EXP 12S SAS Drawer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
1.6.6 EXP 24S SFF Gen2-bay Drawer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
1.7 Comparison between models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
1.8 Build to Order . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
1.9 IBM Editions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
1.9.1 Express editions for IBM i . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
1.9.2 Express editions for Power 720 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
1.10 IBM i Solution Edition for Power 720 and Power 740 . . . . . . . . . . . . . . . . . . . . . . . . . 20
1.11 Model upgrade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
1.11.1 Upgrade considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
1.11.2 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
1.12 Hardware Management Console models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
1.13 System racks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
1.13.1 IBM 7014 Model S25 rack. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
1.13.2 IBM 7014 Model T00 rack. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
1.13.3 IBM 7014 Model T42 rack. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
1.13.4 Feature code 0555 rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
1.13.5 Feature code 0551 rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
1.13.6 Feature code 0553 rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
iv IBM Power 720 and 740: Technical Overview and Introduction
1.13.7 The ac power distribution unit and rack content . . . . . . . . . . . . . . . . . . . . . . . . . 27
1.13.8 Rack-mounting rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
1.13.9 Useful rack additions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
1.13.10 OEM rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Chapter 2. Architecture and technical overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
2.1 The IBM POWER7 processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
2.1.1 POWER7 processor overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
2.1.2 POWER7 processor core . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
2.1.3 Simultaneous multithreading. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
2.1.4 Memory access. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
2.1.5 Flexible POWER7 processor packaging and offerings . . . . . . . . . . . . . . . . . . . . . 41
2.1.6 On-chip L3 cache innovation and Intelligent Cache . . . . . . . . . . . . . . . . . . . . . . . 43
2.1.7 POWER7 processor and Intelligent Energy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
2.1.8 Comparison of the POWER7 and POWER6 processors . . . . . . . . . . . . . . . . . . . 44
2.2 POWER7 processor modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
2.2.1 Modules and cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
2.2.2 Power 720 and Power 740 systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
2.3 Memory subsystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
2.3.1 Registered DIMM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
2.3.2 Memory placement rules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
2.3.3 Memory bandwidth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
2.4 Capacity on Demand. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
2.5 Factory deconfiguration of processor cores . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
2.6 Technical comparison of Power 720 and Power 740 . . . . . . . . . . . . . . . . . . . . . . . . . . 51
2.7 System bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
2.8 Internal I/O subsystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
2.8.1 Slot configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
2.8.2 System ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
2.9 Integrated Virtual Ethernet adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
2.9.1 IVE and SEA implementations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
2.9.2 IVE subsystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
2.10 PCI adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
2.10.1 LAN adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
2.10.2 Graphics accelerators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
2.10.3 SCSI and SAS adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
2.10.4 PCIe RAID & SSD SAS Adapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
2.10.5 iSCSI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
2.10.6 Fibre Channel adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
2.10.7 Fibre Channel over Ethernet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
2.10.8 InfiniBand Host Channel adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
2.10.9 Asynchronous adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
2.11 Internal storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
2.11.1 RAID support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
2.11.2 External SAS port and split backplane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
2.11.3 Media bays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
2.12 External I/O subsystems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
2.12.1 PCI-DDR 12X Expansion Drawer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
2.12.2 12X I/O Drawer PCIe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
2.12.3 Dividing SFF drive bays in a 12X I/O drawer PCIe . . . . . . . . . . . . . . . . . . . . . . . 69
2.12.4 12X I/O drawer PCIe and PCI-DDR 12X Expansion Drawer 12X cabling . . . . . 72
2.12.5 12X I/O Drawer PCIe and PCI-DDR 12X Expansion Drawer SPCN cabling . . . 75
2.13 External disk subsystems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Contents v
2.13.1 EXP 12S SAS Expansion Drawer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
2.13.2 EXP 24S SAS Expansion Drawer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
2.13.3 TotalStorage EXP24 disk drawer and tower . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
2.13.4 IBM TotalStorage EXP24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
2.13.5 IBM System Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
2.14 Hardware Management Console . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
2.14.1 HMC functional overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
2.14.2 HMC connectivity to the POWER7 processor based systems . . . . . . . . . . . . . . 84
2.14.3 HMC high availability. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
2.14.4 HMC code level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
2.15 Integrated Virtualization Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
2.15.1 IBM Systems Director Management Console (SDMC) . . . . . . . . . . . . . . . . . . . . 90
2.16 Operating system support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
2.16.1 Virtual I/O Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
2.16.2 IBM AIX operating system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
2.16.3 IBM i operating system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
2.16.4 Linux operating system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
2.17 Compiler technology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
2.18 Energy management. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
2.18.1 IBM EnergyScale technology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
2.18.2 Thermal power management device card. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Chapter 3. Virtualization. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
3.1 POWER Version 2.2 enhancements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
3.2 POWER Hypervisor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
3.2.1 Virtual SCSI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
3.2.2 Virtual Ethernet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
3.2.3 Virtual Fibre Channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
3.2.4 Virtual (TTY) console . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
3.3 POWER processor modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
3.4 Active Memory Expansion. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
3.5 PowerVM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
3.5.1 PowerVM editions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
3.5.2 Logical partitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
3.5.3 Multiple Shared-Processor Pools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
3.5.4 Virtual I/O Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
3.5.5 PowerVM Lx86 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
3.5.6 PowerVM Live Partition Mobility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
3.5.7 Active Memory Sharing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125
3.5.8 NPIV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
3.5.9 Operating System support for PowerVM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
3.5.10 POWER7-specific Linux programming support. . . . . . . . . . . . . . . . . . . . . . . . . 127
3.6 System Planning Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
Chapter 4. Continuous availability and manageability . . . . . . . . . . . . . . . . . . . . . . . . 131
4.1 Reliability. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132
4.1.1 Designed for reliability. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132
4.1.2 Placement of components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
4.1.3 Redundant components and concurrent repair. . . . . . . . . . . . . . . . . . . . . . . . . . 133
4.2 Availability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
4.2.1 Partition availability priority . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
4.2.2 General detection and deallocation of failing components . . . . . . . . . . . . . . . . . 134
4.2.3 Memory protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136
vi IBM Power 720 and 740: Technical Overview and Introduction
4.2.4 Cache protection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139
4.2.5 Special Uncorrectable Error handling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
4.2.6 PCI extended error handling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
4.3 Serviceability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
4.3.1 Detecting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143
4.3.2 Diagnosing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
4.3.3 Reporting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
4.3.4 Notifying . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
4.3.5 Locating and servicing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
4.4 Manageability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154
4.4.1 Service user interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154
4.4.2 IBM Power Systems firmware maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
4.4.3 Electronic Services and Electronic Service Agent . . . . . . . . . . . . . . . . . . . . . . . 163
4.5 Operating system support for RAS features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164
Related publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167
IBM Redbooks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167
Other publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167
Online resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168
How to get Redbooks publications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169
Help from IBM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169
© Copyright IBM Corp. 2010. All rights reserved. vii
Notices
This information was developed for products and services offered in the U.S.A.
IBM may not offer the products, services, or features discussed in this document in other countries. Consult
your local IBM representative for information on the products and services currently available in your area. Any
reference to an IBM product, program, or service is not intended to state or imply that only that IBM product,
program, or service may be used. Any functionally equivalent product, program, or service that does not
infringe any IBM intellectual property right may be used instead. However, it is the user's responsibility to
evaluate and verify the operation of any non-IBM product, program, or service.
IBM may have patents or pending patent applications covering subject matter described in this document. The
furnishing of this document does not give you any license to these patents. You can send license inquiries, in
writing, to:
IBM Director of Licensing, IBM Corporation, North Castle Drive, Armonk, NY 10504-1785 U.S.A.
The following paragraph does not apply to the United Kingdom or any other country where such
provisions are inconsistent with local law: INTERNATIONAL BUSINESS MACHINES CORPORATION
PROVIDES THIS PUBLICATION "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR
IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT,
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of
express or implied warranties in certain transactions, therefore, this statement may not apply to you.
This information could include technical inaccuracies or typographical errors. Changes are periodically made
to the information herein; these changes will be incorporated in new editions of the publication. IBM may make
improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time
without notice.
Any references in this information to non-IBM websites are provided for convenience only and do not in any
manner serve as an endorsement of those websites. The materials at those websites are not part of the
materials for this IBM product and use of those websites is at your own risk.
IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring
any obligation to you.
Information concerning non-IBM products was obtained from the suppliers of those products, their published
announcements or other publicly available sources. IBM has not tested those products and cannot confirm the
accuracy of performance, compatibility or any other claims related to non-IBM products. Questions on the
capabilities of non-IBM products should be addressed to the suppliers of those products.
This information contains examples of data and reports used in daily business operations. To illustrate them
as completely as possible, the examples include the names of individuals, companies, brands, and products.
All of these names are fictitious and any similarity to the names and addresses used by an actual business
enterprise is entirely coincidental.
COPYRIGHT LICENSE:
This information contains sample application programs in source language, which illustrate programming
techniques on various operating platforms. You may copy, modify, and distribute these sample programs in
any form without payment to IBM, for the purposes of developing, using, marketing or distributing application
programs conforming to the application programming interface for the operating platform for which the sample
programs are written. These examples have not been thoroughly tested under all conditions. IBM, therefore,
cannot guarantee or imply reliability, serviceability, or function of these programs.
viii IBM Power 720 and 740: Technical Overview and Introduction
Trademarks
IBM, the IBM logo, and ibm.com are trademarks or registered trademarks of International Business Machines
Corporation in the United States, other countries, or both. These and other IBM trademarked terms are
marked on their first occurrence in this information with the appropriate symbol (® or ™), indicating US
registered or common law trademarks owned by IBM at the time this information was published. Such
trademarks may also be registered or common law trademarks in other countries. A current list of IBM
trademarks is available on the web at http://www.ibm.com/legal/copytrade.shtml
The following terms are trademarks of the International Business Machines Corporation in the United States,
other countries, or both:
Active Memory™
AIX 5L™
AIX®
DS8000®
Electronic Service Agent™
EnergyScale™
Focal Point™
IBM Systems Director Active Energy
Manager™
IBM®
Micro-Partitioning™
Power Architecture®
POWER Hypervisor™
Power Systems™
Power Systems Software™
POWER4™
POWER4+™
POWER5™
POWER5+™
POWER6+™
POWER6®
POWER7™
PowerHA™
PowerPC®
PowerVM™
POWER®
pSeries®
Rational Team Concert™
Rational®
Redbooks®
Redpaper™
Redbooks (logo) ®
RS/6000®
System p5®
System p®
System Storage®
System z®
Tivoli®
TotalStorage®
Workload Partitions Manager™
XIV®
The following terms are trademarks of other companies:
Microsoft, and the Windows logo are trademarks of Microsoft Corporation in the United States, other
countries, or both.
Intel, Intel logo, Intel Inside logo, and Intel Centrino logo are trademarks or registered trademarks of Intel
Corporation or its subsidiaries in the United States and other countries.
UNIX is a registered trademark of The Open Group in the United States and other countries.
Linux is a trademark of Linus Torvalds in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of others.
© Copyright IBM Corp. 2010. All rights reserved. ix
Preface
This IBM® Redpaper™ publication is a comprehensive guide covering the IBM Power 720
and Power 740 servers supporting AIX®, IBM i, and Linux® operating systems. The goal of
this paper is to introduce the innovative Power 720 and Power 740 offerings and their major
functions, including these:
The IBM POWER7™ processor available at frequencies of 3.0 GHz, 3.55 GHz, and
3.7 GHz
The specialized POWER7 Level 3 cache that provides greater bandwidth, capacity, and
reliability
The 1 Gb or 10 Gb Integrated Virtual Ethernet adapter, included with each server
configuration, providing native hardware virtualization
The latest IBM PowerVM™ virtualization, including PowerVM Live Partition Mobility and
PowerVM IBM Active Memory™ Sharing
Active Memory Expansion technology that provides more usable memory than is
physically installed in the system
IBM EnergyScale™ technology that provides features such as power trending,
power-saving, capping of power, and thermal measurement
Professionals who want to acquire a better understanding of IBM Power Systems™ products
can benefit from reading this Redpaper publication. The intended audience includes the
following roles:
Clients
Sales and marketing professionals
Technical support professionals
IBM Business Partners
Independent software vendors
This paper complements the available set of IBM Power Systems documentation by providing
a desktop reference that offers a detailed technical description of the Power 720 and
Power 740 systems.
This paper does not replace the latest marketing materials and configuration tools. It is
intended as an additional source of information that, together with existing sources, can be
used to enhance your knowledge of IBM server solutions.
The team who wrote this paper
This paper was produced by a team of specialists from around the world working at the
International Technical Support Organization, Austin Center, Texas. The project that produced
this publication was managed by Scott Vetter.
An Ding Chen is a Power systems Product Engineer in Shanghai China, who provides level 3
hardware and firmware support in all Asia Pacific countries and Japan. He has ten years
experience on AIX/UNIX®, IBM RS/6000®, IBM pSeries®, and Power Systems products.
Starting from his university, he has passed the CATE certification on pSeries systems and
IBM AIX 5L™. He joined IBM in 2006.
x IBM Power 720 and 740: Technical Overview and Introduction
James Cruickshank works on the Power Systems Field Technical Sales Support team for
IBM in the UK. He holds an honors degree in Mathematics from the University of Leeds.
James has nine years of experience working on RS/6000, IBM System p®, and Power
Systems products and is a member of the EMEA Power Champions team. James supports
customers in the financial services sector in the UK.
Carlo Costantini is a Certified IT Specialist for IBM and has over 32 years of experience with
IBM and IBM Business Partners. He currently works in Italy Power Systems Platforms as
Presales Field Technical Sales Support for IBM Sales Representatives and IBM Business
Partners. Carlo has broad marketing experience and his current major areas of focus are
competition, sales, and technical sales support. He is a certified specialist for Power Systems
servers. He holds a Masters degree in Electronic Engineering from Rome University.
Volker Haug is a certified Consulting IT Specialist within IBM Systems and Technology
Group, based in Ehningen, Germany. He holds a Bachelor's degree in Business Management
from the university of Applied Studies in Stuttgart. His career has included more than 23
years working in the IBM PLM and Power Systems divisions as a RISC and AIX Systems
Engineer. Volker is an expert in Power Systems hardware, AIX, and PowerVM virtualization.
He is a member of the EMEA Power Champions team and also a member of the German
Technical Expert Council, a affiliate of the IBM Academy of Technology. He has written
various books and white papers about AIX, workstations, servers, and PowerVM
virtualization.
Cesar Diniz Maciel is a Senior Consulting IT Specialist with IBM in the United States. He
joined IBM in 1996 as Presales Technical Support for the RS/6000 family of UNIX servers in
Brazil, and came to IBM United States in 2005. He is part of the Global Techline team,
working on presales consulting for Latin America. He holds a degree in Electrical Engineering
from Universidade Federal de Minas Gerais (UFMG) in Brazil. His areas of expertise include
Power Systems, AIX, and IBM POWER® Virtualization. He has written extensively on Power
Systems and related products. This is his seventh ITSO residency.
John T Schmidt is an Accredited IT Specialist for IBM and has ten years experience with
IBM and Power Systems. He has a degree in Electrical Engineering from the University of
Missouri - Rolla and an MBA from Washington University in St. Louis. In 2010, he completed
an assignment with the IBM Corporate Service Corps in Hyderabad, India. He is currently
working in the United States as a presales Field Technical Sales Specialist for Power
Systems in St. Louis, MO.
The project that produced this publication was managed by:
Scott Vetter, IBM certified project manager and PMP.
Preface xi
Thanks to the following people for their contributions to this project:
Salim Agha, Ray W. Anderson, Richard W. Bishop, Joe Cahill, Scott A. Carroll, Sertac Cakici,
Hsien-I Chang, Binh Chu, Michael Floyd, George Gaylord, John Gressett,
Raymond J. Harrington, Daniel Henderson, John Hilburn, Bob Kovacs, Walter M. Lipp,
Mary E. Magnuson, Bill McWaters, Duc T. Nguyen, Thoi Nguyen, Guy R. Paradise,
David Pirnik, Todd J. Rosedahl, Pat O’Rourke, Amartey S. Pearson, Jeff Scheel,
Joseph C. Schiavone, Irene Sideris, Timothy Stack, Guido Somers, Vasu Vallabhaneni,
Jesus G. Villarreal
IBM U.S.A.
Sabine Jordan, Stephen Lutz
IBM Germany
Tamikia Barrow, Brooke C Gardner
International Technical Support Organization, Austin Center
Now you can become a published author, too!
Here's an opportunity to spotlight your skills, grow your career, and become a published
author - all at the same time! Join an ITSO residency project and help write a book in your
area of expertise, while honing your experience using leading-edge technologies. Your efforts
will help to increase product acceptance and customer satisfaction, as you expand your
network of technical contacts and relationships. Residencies run from two to six weeks in
length, and you can participate either in person or as a remote resident working from your
home base.
Find out more about the residency program, browse the residency index, and apply online at:
ibm.com/redbooks/residencies.html
Comments welcome
Your comments are important to us!
We want our papers to be as helpful as possible. Send us your comments about this paper or
other IBM Redbooks publications in one of the following ways:
Use the online Contact us review Redbooks form found at:
ibm.com/redbooks
Send your comments in an email to:
redbooks@us.ibm.com
Mail your comments to:
IBM Corporation, International Technical Support Organization
Dept. HYTD Mail Station P099
2455 South Road
Poughkeepsie, NY 12601-5400
xii IBM Power 720 and 740: Technical Overview and Introduction
Stay connected to IBM Redbooks publications
Find us on Facebook:
http://www.facebook.com/IBMRedbooks
Follow us on twitter:
http://twitter.com/ibmredbooks
Look for us on LinkedIn:
http://www.linkedin.com/groups?home=&gid=2130806
Explore new Redbooks publications, residencies, and workshops with the IBM Redbooks
publications weekly newsletter:
https://www.redbooks.ibm.com/Redbooks.nsf/subscribe?OpenForm
Stay current on recent Redbooks publications with RSS Feeds:
http://www.redbooks.ibm.com/rss.html
© Copyright IBM Corp. 2010. All rights reserved. 1
Chapter 1. General description
The IBM Power 720 (8202-E4B) and IBM Power 740 (8205-E6B) servers utilize the latest
POWER7 processor technology designed to deliver unprecedented performance, scalability,
reliability, and manageability for demanding commercial workloads.
The performance, availability, and flexibility of the Power 720 server can enable companies to
spend more time running their business utilizing a proven solution from thousands of ISVs
that support the AIX, IBM i, and Linux operating systems.
The Power 720 server is a high-performance, energy efficient, reliable, and secure
infrastructure and application server in a dense form factor. As a high-performance
infrastructure or application server, the Power 720 contains innovative workload-optimizing
technologies that maximize performance based on client computing needs and Intelligent
Energy features that help maximize performance and optimize energy efficiency, resulting in
one of the most cost-efficient solutions for UNIX, IBM i, and Linux deployments.
As a distributed application server, the IBM Power 720 is designed with capabilities to deliver
leading-edge application availability and enable more work to be processed with less
operational disruption for branch office and in-store applications. As a consolidation server,
PowerVM Editions provide the flexibility to use leading-edge AIX, IBM i, Linux, and x86 Linux
applications and offer comprehensive virtualization technologies designed to aggregate and
manage resources while helping to simplify and optimize your IT infrastructure and deliver
one of the most cost-efficient solutions for UNIX, IBM i and Linux deployments.
The Power 740 offers the performance, capacity, and configuration flexibility to meet the most
demanding growth requirements, and combined with industrial-strength PowerVM
virtualization for AIX, IBM i, and Linux, can fully utilize the capability of the system. These
capabilities are designed to satisfy even the most demanding processing environments and
can deliver business advantages and higher client satisfaction.
The Power 740 is designed with innovative workload-optimizing and energy management
technologies to help clients get the most out of their systems; that is, running applications
rapidly and energy efficiently to conserve energy and reduce infrastructure costs. It is fueled
by the outstanding performance of the POWER7 processor, making it possible for
applications to run faster with fewer processors, resulting in lower per-core software licensing
costs.
1
2 IBM Power 720 and 740: Technical Overview and Introduction
1.1 Systems
Figure 1-1 shows the Power 720 rack and tower models.
Figure 1-1 Power 720 rack and tower models
Chapter 1. General description 3
Figure 1-2 shows the Power 740 rack and tower models.
Figure 1-2 Power 740 rack and tower models
1.1.1 The Power 720 server
The Power 720 offers a choice of a 4-core, 6-core, or 8-core configuration, available in a 4U
rack-mount or a tower form factor. The POWER7 processor chips in this server are 64-bit,
4-core, 6-core and 8-core modules with 4 MB of L3 cache per core and 256 KB of L2 cache
per core.
The Power 720 server supports a maximum of 16 DDR3 DIMM slots, with eight DIMM slots
included in the base configuration and eight DIMM slots available with an optional memory
riser card. A system with the optional memory riser card installed has a maximum memory of
128 GB.
The Power 720 system offers two storage backplanes. The first one supports up to six SFF
SAS HDDs/SSDs, an SATA DVD, and a half-high tape drive. The second one is a
higher-function backplane that supports up to eight SFF SAS HDDs/SSDs, an SATA DVD, a
half-high tape drive, Dual 175 MB Write Cache RAID, and an external SAS port. All
HDDs/SSDs are hot-swap and front accessible.
4 IBM Power 720 and 740: Technical Overview and Introduction
The Power 720 comes with four PCI Express (PCIe) full height profile slots for installing
adapters in the system. Optionally an additional riser card with four PCIe low profile (LP) slots
can be installed in a GX++ slot available on the backplane. This extends the number of slots
to eight.
If additional slots are required, the Power 720 supports external I/O drawers in place of the
riser card, allowing for a maximum of two 5802/5877 PCIe drawers or four 5796 PCI-X
drawers. Note that only the 6-core and 8-core systems support external I/O slots.
In the Power 720 system units there is a choice of quad gigabit or dual 10 Gb Integrated
Virtual Ethernet (IVE) adapters. These native ports can be selected at the time of initial order.
Virtualization of these integrated Ethernet adapters is supported.
1.1.2 The Power 740 server
The IBM Power 740 server is a 4U rack-mount or tower server with two processor sockets
offering 4-core 3.3 GHz and 3.7 GHz, 6-core 3.7 GHz, and 8-core 3.55 GHz processor
options. The POWER7 processor chips in this server are 64-bit, 4-core, 6-core, and 8-core
modules with 4 MB of L3 cache per core and 256 KB of L2 cache per core.
The Power 740 server supports a maximum of 32 DDR3 DIMM slots, with eight DIMM slots
included in the base configuration and 24 DIMM slots available with three optional memory
riser cards. A system with three optional memory riser cards installed has a maximum
memory of 256 GB.
The Power 740 system offers two storage backplanes. The first supports up to six SFF SAS
HDDs/SSDs, an SATA DVD, and a half-high tape drive. The second is a higher-function
backplane that supports up to eight SFF SAS HDDs/SSDs, an SATA DVD, a half-high tape
drive, Dual 175 MB Write Cache RAID, and an external SAS port. All HDDs/SSDs are
hot-swap and front accessible.
The Power 740 comes with four PCI Express (PCIe) full height profile slots for installing
adapters in the system. Optionally an additional riser card with four PCIe low profile (LP) slots
can be installed in a GX++ slot available on the backplane. This extends the number of slots
to eight.
If additional slots are required, the Power 740 supports external I/O drawers, allowing for a
maximum of four 5802/5877 PCIe drawers or four 5796 PCI-X drawers.
You also have the choice of quad gigabit or dual 10 Gb Integrated Virtual Ethernet (IVE)
adapters for the Power 740 servers. These native ports can be selected at the time of initial
order. Virtualization of these integrated Ethernet adapters is supported.
Chapter 1. General description 5
1.2 Operating environment
The operating environment specifications for the servers can be seen in Table 1-1:
Table 1-1 Operating environment for Power 720 and Power 740
Power 720 and Power 740 operating environment
Description Operating Non-operating
Power 720 Power 740 Power 720 Power 740
Temperature 5 to 35 degrees C (41 to 95 degrees F)
Preferable: 18 to 27 degrees C
(64 to 80 degrees F)
5 to 45 degrees C (41 to 113 degrees F)
Relative humidity 20% to 60% 8% to 80%
Maximum dew
point
28 degrees C (84 degrees F) 28 degrees C (82 degrees F)
Operating
voltage
100 to 127 VAC or
200 to 240 VAC
200 to 240 V
AC
n/a
Operating
frequency
50 to 60 +/- 3 Hz n/a
Power
consumption
750 watts
maximum
1400 watts
maximum
n/a
Power source
loading
0.765 kVA
maximum
1.1428 kVA
maximum
n/a
Thermal output 2560 Btu/hour
maximum
4778 Btu/hour
maximum
n/a
Maximum
altitude
3048 m
(10,000 ft)
n/a
Noise level
reference point:
Tower system:
5.4 bels
(operating/idle)
Rack system:
5.4 bels
(operating/idle)
Tower system:
5.8 bels
(operating/idle)
Rack system:
5.8 bels
(operating/idle)
n/a
6 IBM Power 720 and 740: Technical Overview and Introduction
1.3 Physical package
The Power 720 and Power 740 are available in both rack-mount and tower form factors. The
major physical attributes for each are discussed in the following sections.
1.3.1 Tower model
The Power 720 and Power 740 can each be configured as tower models by selecting features
shown in Table 1-2.
Table 1-2 Features for selecting tower models
Table 1-3 shows the physical dimensions of the tower models.
Table 1-3 Physical dimensions of the Power 720 and Power 740 tower chassis
1.3.2 Rack-mount model
The Power 720 and Power 740 can be configured as 4U (4EIA) rack-mount models by
selecting features shown in Table 1-4.
Table 1-4 Features for selecting rack-mount models
Table 1-5 shows the physical dimensions of the rack-mount models
Table 1-5 Physical dimensions of the Power 720 and Power 740 rack-mount chassis
Cover Set Power 720 Power 740
IBM Tower Cover Set #7567 #7572
OEM Tower Cover Set #7568 #7573
Dimension Power 720 Power 740
Width without tip plate 183 mm (7.2 in) 183 mm (7.2 in)
Width with tip plate 328.5 mm (12.9 in) 328.5 mm (12.9 in)
Depth 688 mm (27.1 in) 688 mm (27.1 in)
Height 541 mm (21.3 in) 541 mm (21.3 in)
Weight without tip plate 53.7 kg (118.1 lb) 53.7 kg (118.1 lb)
Weight with tip plate 57.2 kg (125.8 lb) 57.2 kg (125.8 lb)
Cover Set Power 720 Power 740
IBM Rack-mount Drawer Bezel and Hardware #7134 #7131
OEM Rack-mount Drawer Bezel and Hardware #7135 #7132
Dimension Power 720 Power 740
Width 440 mm (17.3 in) 440 mm (17.3 in)
Depth 610 mm (24.0 in) 610 mm (24.0 in)
Height 173 mm (6.81 in) 173 mm (6.81 in)
Weight 48.7 kg (107.4 lb) 48.7 kg (107.4 lb)
Chapter 1. General description 7
Figure 1-3 shows the rear view of a Power 740 with the optional PCIe expansion.
Figure 1-3 Rear view of a rack-mount Power 740 server
1.4 System features
The system chassis contains one processor module (Power 720) or up to two processor
modules (Power 740). Each POWER7 processor module has either 4-cores, 6-cores, or
8-cores. Each of the POWER7 processor chips in the server has a 64-bit architecture, up to
2 MB of L2 cache (256 KB per core) and up to 32 MB of L3 cache (4 MB per core).
1.4.1 Power 720 system features
The following summary describes the standard features:
Tower or rack-mount (4U) chassis
4-core, 6-core, or 8-core configuration with one 3.0 GHz processor module
Up to 128 GB of 1066 MHz DDR3 ECC memory
Choice of two disk/media backplanes:
– Six 2.5-inch HDD/SSD/Media backplane with one tape drive bay and one DVD bay
– Eight x 2.5-inch HDD/SSD/Media backplane with one tape drive bay, one DVD bay, and
one external SAS port
External
SAS Port
Optional
4 x PCIe x8
Slots 4 x PCIe x8 Slots
GX++ Slot 1
(shared with PCIe
expansion feature)
System
Ports SPCN
Ports Integrated
Virtual
Ethernet
HMC
Ports
USB
Ports
GX++
Slot 2
8 IBM Power 720 and 740: Technical Overview and Introduction
Choice of three Integrated Virtual Ethernet daughter cards:
– Quad-port 1 Gb Copper IVE
– Dual-port 10 Gb SFP+ TwinAx Cu IVE
– Dual-port 10 Gb SFP+ Fiber IVE
A maximum of eight PCIe slots:
– Four PCIe x8 full height short card slots
– Optional four PCIe x8 low profile short card slots
One GX++ slot
Integrated:
– Service Processor
– EnergyScale technology
– Hot-swap and redundant cooling
– Three USB ports and two system ports
– Two HMC ports and two SPCN ports
Optional redundant, 1725 Watt ac hot-swap power supplies
1.4.2 Power 740 system features
The following summary describes the standard features:
Tower or rack-mount (4U) chassis
Processors:
– 4-core or 8-core configuration with one or two 3.3 GHz or 3.7 GHz 4-core processor
modules
– 6-core or 12-core configuration with one or two 3.7 GHz 6-core processor modules
– 8 or 16-core configuration with two 3.55 GHz 8-core processor modules
Up to 256 GB of 1066 MHz DDR3 ECC memory
Choice of two disk/media backplanes:
– Six x 2.5-inch HDD/SSD/Media backplane with one tape drive bay and one DVD bay
– Eight x 2.5-inch HDD/SSD/Media backplane with one tape drive bay, one DVD bay and
one external SAS port
Choice of three Integrated Virtual Ethernet daughter cards:
– Quad-port 1 Gb Copper IVE
– Dual-port 10 Gb SFP+ TwinAx Cu IVE
– Dual-port 10 Gb SFP+ Fiber IVE
A maximum of eight PCIe slots:
– Four PCIe x8 full height short card slots
– Optional four PCIe x8 low profile short card slots
Two GX++ slots
Integrated:
– Service Processor
– EnergyScale technology
– Hot-swap and redundant cooling
– Three USB ports and two system ports
– Two HMC ports and two SPCN ports
Redundant, 1725 Watt ac hot-swap power supplies
Chapter 1. General description 9
1.4.3 Minimum features
Each system has a minimum feature-set in order to be valid.
The minimum configuration must include a processor, processor activations, memory, a
power supply, a power cord (two power supplies and two power cords for the Power 740), one
or two DASD, a DASD/SSD/Media backplane, an Integrated Virtual Ethernet daughter card, a
DVD-RAM, an operating system indicator, and a Language Group Specify.
If IBM i is the Primary Operating System (#2145), the initial order must also include one
additional HDD/SSD, a Mirrored System Disk Level Specify Code, and a System Console on
HMC Indicator. A DVD is defaulted on every order but can be de-selected. A DVD-ROM or
DVD-RAM must be accessible by the system.
1.4.4 Power supply features
One system 1725 watt ac power supply (#5603) is required for the Power 720. A second
power supply is optional. Two system 1725 watt ac power supplies (#5603) are required for
the Power 740. The second power supply provides redundant power for enhanced system
availability. To provide full redundancy, the two power supplies must be connected to separate
PDUs.
The server will continue to function with one working power supply. A failed power supply can
be hot swapped but must remain in the system until the replacement power supply is available
for exchange.
1.4.5 Processor module features
Each of the processor modules in the system houses a single POWER7 processor chip.
The processor has either 4-cores, 6-cores, or 8-cores. The Power 720 supports one
processor module. The Power 740 supports a second processor module that must be
identical to the first.
The amount of processor activation code features must be equal to the amount of installed
processor cores.
Note: If AIX, IBM i, or Linux is the primary operating system, no internal HDD or SSD is
required if feature #0837 (Boot from SAN) is selected. A Fibre Channel or FCoE adapter
must be ordered if #0837 is selected.
10 IBM Power 720 and 740: Technical Overview and Introduction
Table 1-6 summarizes the processor features available for the Power 720.
Table 1-6 Processor features for the Power 720
Table 1-7 summarizes the processor features available for the Power 740.
Table 1-7 Processor features for the Power 740
1.4.6 Memory features
In POWER7 processor-based systems, DDR3 memory is used throughout. The POWER7
DDR3 memory uses a new memory architecture to provide greater bandwidth and capacity.
This enables operating at a higher data rate for larger memory configurations.
Memory in the Power 720 and 740 systems installed into memory riser cards. One memory
riser card is included in the base system. The base memory riser card does not appear as a
feature code in the configurator. Additional memory riser cards, feature #5604, can be
installed up to a maximum of two per processor module. Each memory riser card provides
eight DDR3 DIMM slots. DIMMs are available in capacities of 4 GB and 8 GB at 1066 MHz.
All DIMMs are installed in pairs.
Table 1-8 shows memory features available on the systems.
Table 1-8 Summary of memory features
It is generally best that memory be installed evenly across all memory riser cards in the
system. Balancing memory across the installed memory riser cards allows memory access in
a consistent manner and typically results in the best possible performance for your
configuration. However, balancing memory fairly evenly across multiple memory riser cards,
compared to balancing memory exactly evenly typically has a very small performance
difference.
Feature code Processor module description
#8350 4-core 3.0 GHz POWER7 processor module
#8351 6-core 3.0 GHz POWER7 processor module
#8352 8-core 3.0 GHz POWER7 processor module
Feature code Processor module description Min/max
modules
#8353 4-core 3.3 GHz POWER7 processor module 1/2
#8347 4-core 3.7 GHz POWER7 processor module 1/2
#8354 6-core 3.7 GHz POWER7 processor module 1/2
#8355 8-core 3.55 GHz POWER7 processor module 1/2
Feature code Feature capacity Access rate DIMMs
#4526 8 GB 1066 MHz 2 x 4 GB DIMMs
#4529a
a. A Power 720 system with the 4-core processor module (#8350) does not support the 16 GB
memory feature #4529.
16 GB 1066 MHz 2 x 8 GB DIMMs
Chapter 1. General description 11
1.5 Disk and media features
The Power 720 and 740 systems feature one SAS DASD controller with two storage
backplane options:
The first (#5618) supports up to six SFF SAS HDDs/SSDs, a SATA DVD, and a half-high
tape drive for either a tape drive or USB removable disk. This feature does not provide
RAID 5, RAID 6, a write cache, or an external SAS port. Split backplane functionality (3x3)
and RAID 10 is supported with the additional feature #5631.
The second (#5630) is a higher-function backplane that supports up to eight SFF SAS
HDDs/SSDs, a SATA DVD, a half-high tape drive for either a tape drive or USB removable
disk, Dual 175 MB Write Cache RAID, and one external SAS port. The #5630 supports
RAID 5 and RAID 6 and there is no split backplane available for this feature.
All HDDs/SSDs are hot-swap and front accessible.
Table 1-9 shows the available disk drive feature codes to be installed in the Power 720 and
Power 740.
Table 1-9 Disk drive feature code description
Notes:
No additional PCIe SAS adapter is required for Split Backplane.
The feature #5618 is not supported with IBM i.
Feature code Description OS support
#1775 177 GB SFF-1 SSD w/ eMLC AIX, Linux
#1787 177 GB SFF-1 SSD w/ eMLC IBM i
#1793 177 GB SFF-2 SSD w/ eMLC AIX, Linux
#1794 177 GB SFF-2 SSD w/ eMLC IBM i
#1790 600 GB 10K RPM SAS SFF Disk Drive AIX, Linux
#1885 300 GB 10K RPM SFF SAS Disk Drive AIX, Linux
#1886 146.8 GB 15K RPM SFF SAS Disk Drive AIX, Linux
#1888 139.5 GB 15K RPM SFF SAS Disk Drive IBM i
#1911 283 GB 10K RPM SFF SAS Disk Drive IBM i
#1916 571 GB 10k RPM SAS SFF Disk Drive IBM i
#1917 146 GB 15k RPM SAS SFF-2 Disk Drive AIX, Linux
#1925 300 GB 10k RPM SAS SFF-2 Disk Drive AIX, Linux
#1947 139 GB 15k RPM SAS SFF-2 Disk Drive IBM i
#1956 283 GB 10k RPM SAS SFF-2 Disk Drive IBM i
#1962 571 GB 10k RPM SAS SFF-2 Disk Drive IBM i
#1964 600 GB 10k RPM SAS SFF-2 Disk Drive AIX, Linux
#1995 177 GB 1.8” SATA Solid State Drive AIX, Linux
#1996 177 GB 1.8” SATA Solid State Drive IBM i
12 IBM Power 720 and 740: Technical Overview and Introduction
#1817 Quantity 150 of #1962
#1818 Quantity 150 of #1964
#1844 Quantity 150 of #1956
#1866 Quantity 150 of #1917
#1868 Quantity 150 of #1947
#1869 Quantity 150 of #1925
#1887 Quantity 150 of #1793
#1958 Quantity 150 of #1794
Feature code Description OS support
Chapter 1. General description 13
Note: Be aware of the following considerations for disks:
No internal HDD/SSD is required if #0837 is selected. This will indicate a boot from
SAN. In this case, a Fibre Channel or Fibre Channel over Ethernet adapter must also
be ordered.
SSDs are not supported by #5278 or #5901, and #5912 SAS adapters.
SAS-bay-based SSD options are enhanced with a 177 GB SSD, with eMLC (#1775,
#1787) which provides 2.5 times more capacity per drive than the current 69 GB SSD
(#1890 and #1909. The 177 GB drive provides a much improved cost per gigabyte and
requires a smaller number of SAS bays for the same number of gigabytes. A few
SSDs may reduce the need for many HDDs, saving rack space, I/O drawers,
maintenance, and energy. SSDs can often do so while improving system performance
and batch windows at the same time. Four feature codes are used for this drive to
indicate if it is used for AIX/Linux or IBM i and to indicate what type of SFF SAS bay in
which it is placed .Two features (#1793, and #1794) are Gen2 carrier for use on the
EXP 24S SFF Gen2-bay Drawer (#5887)
The SSDs #1775, #1787, #1793 and #1794 can be controlled by:
– The imbedded SAS controllers in the previously listed POWER7 system units
(Power 710 and Power 740).
– The PCIe 380 MB Cache SAS RAID Adapter (#5805)
– The PCI-X 1.5 GB Cache SAS RAID Adapter (#5908)
The maximum number of SSD drive features per controller depends upon the
enclosure in which the SSD are placed and the SAS controller, which is running the
SSD.
– Imbedded SAS controllers can attach up to the maximum number of bays in the
system unit, an attachment maximum of six or eight.
– The PCIe 380 MB Cache SAS RAID Adapter (#5805) can attach up to a total of
nine SSD per pair of adapters.
– The PCI-X 1.5 GB Cache SAS RAID Adapter (#5908) can attach up to a total of
eight SSD.
SSDs and HDDs are not allowed to mirror each other.
SSF-2 disk drives require a Gen2 SFF carrier/tray for use in an EXP 24S I/O
drawer(#5887).
The 177 GB SAS SSD (#1995 and #1996) requires to be installed into one of the PCIe
RAID & SSD SAS adapters (#2053, #2054, or #2055). For more detailed information
about this option, see 2.10.4, “PCIe RAID & SSD SAS Adapter” on page 58.
In a Power 720 and Power 740 with a split backplane, SSDs and HDDs may be placed
in either "split" but no mixing of SSDs and HDDs within a split is allowed. IBM i does not
support split backplane.
In a Power 720 and Power 740 without a split backplane, SSDs and HDDs may be
mixed in any combination. However, they cannot be in the same RAID array.
If IBM i is the primary operating system (#2145), a minimum of two HDDs/SSDs are
required.
14 IBM Power 720 and 740: Technical Overview and Introduction
If you need more disks than available with the internal disk bays, you can attach additional
external disk subsystems.
SCSI disks are not supported in the Power 720 and 740 disk bays. However, if you want to
use SCSI disks, you can attach existing SCSI disk subsystems.
For more detailed information about the available external disk subsystems, see 2.13,
“External disk subsystems” on page 75.
The Power 720 and 740 have a slim media bay that can contain an optional DVD-RAM
(#5762) and a half-high bay that can contain a tape drive or removable disk drive.
Table 1-10 shows the available media device feature codes for Power 720 and 740.
Table 1-10 Media device feature code description for Power 720 and 740
1.6 I/O drawers for Power 720 and Power 740 servers
The Power 720 and the Power 740 servers supports the following 12X attached I/O drawers,
providing extensive capability to expand the overall server expandability and connectivity.
Feature #5802 provides PCIe slots and SFF SAS disk slots
Feature #5877 provides PCIe slots
Feature #5796 provides PCI-X slots
The 7314-G30 drawer provides PCI-X slots (because the 7314-G30 has been withdrawn
from marketing it is supported, but no longer orderable)
Three disk-only I/O drawers are also supported, providing large storage capacity and multiple
partition support:
Feature #5886 EXP 12S holds a 3.5-inch SAS disk or SSD
Feature #5887 EXP 24S SFF Gen2-bay Drawer for high-density storage holds SAS Hard
Disk drives.
Feature code Description
#5762 SATA Slimline DVD-RAM Drive
#5619 80/160 GB DAT160 Tape-SAS
#5638 1.5 TB/3.0 TB LTO-5 Tape-SAS
#5746 800 GB/1.6 TB LTO4 Tape-SAS
#1103 USB Internal Docking Station for Removable Disk Drive
#1104 USB External Docking Station for Removable Disk Drive
Note: Take notice of the following considerations for tape drives and USB disk drives:
If tape device feature #5619, #5638, or #5746 is installed in the half-high media bay,
feature #3656 must be also selected.
A half-high tape feature and a feature #1103 Removable USB Disk Drive Docking
Station are mutually exclusive. One or the other can be in the half-high bay in the
system but not both. As for the tape drive, the #3656 is not required with #1103.
Chapter 1. General description 15
Feature #5786 and #5787 EXP24 holds a 3.5-inch SCSI disk (used for migrating existing
SCSI drives).
The 7031-D24 holds a 3.5-inch SCSI disk (supported but not orderable).
The Power 720 provides one GX++ slot, offering one loop. The Power 740 has one GX++
slot, if one processor module is installed, and two GX++ slots, when two processor modules
are installed. Thus, the Power 740 provides one or two loops.
1.6.1 12X I/O Drawer PCIe
The #5802 and #5877 expansion units are 19-inch, rack-mountable, I/O expansion drawers
that are designed to be attached to the system using 12x double date rate (DDR) cables. The
expansion units can accommodate ten generation 3 blind-swap cassettes. These cassettes
can be installed and removed without removing the drawer from the rack.
A maximum of two #5802 drawers can be placed on the same 12X loop. The #5877 drawer is
the same as #5802 except it does not support any disk bays. The #5877 I/O drawer can be on
the same loop as the #5802 I/O drawer. Note that #5877 cannot be upgraded to #5802.
The I/O drawer has the following attributes:
Eighteen SAS hot-swap SFF disk bays (only #5802)
Ten PCI-e based I/O adapter slots. Blind-swap
Redundant hot-swappable power and cooling units
1.6.2 PCI-X DDR 12X Expansion Drawer
The PCI-X DDR 12X Expansion Drawer (#5796) is a 4 EIA unit tall drawer and mounts in a
19-inch rack. Feature 5796 takes up half the width of the 4 EIA rack space and requires the
use of a #7314 drawer mounting enclosure. The 4 EIA tall enclosure can hold up to two #5796
drawers mounted side by side in the enclosure. A maximum of four #5796 drawers can be
placed on the same 12X loop.
The I/O drawer has the following attributes:
4 EIA unit rack-mount enclosure (#7314) holding one or two #5796 drawers.
Six PCI-X DDR slots: 64-bit, 3.3V, 266 MHz. Blind-swap.
Redundant hot-swappable power and cooling units.
Note: The 4-core Power 720 does not support the attachment of 12X I/O drawers or the
attachment of disk drawers such as the #5886 EXP12S drawer, #5786 EXP24 drawer, and
#5787 EXP24 tower.
Note: Mixing #5802/5877 and #5796 on the same loop is not supported. Mixing #5802 and
#5877 on the same loop is supported with a maximum of two drawers total per loop.
Note: Mixing #5802/5877 and #5796 on the same loop is not supported. Mixing #5796 and
the 7314-G30 on the same loop is supported with a maximum of four drawers total per
loop.
16 IBM Power 720 and 740: Technical Overview and Introduction
1.6.3 PCI-X DDR 12X Expansion Drawer
The 7314-G30 is equivalent to the #5796 I/O drawer described before. It provides the same
six PCI-X DDR slots per unit and has the same configuration rules/considerations as #5796.
1.6.4 I/O drawers and usable PCI slot
The various I/O drawer model types can be intermixed on a single server within the
appropriate I/O loop. Depending on the system configuration, the maximum number of I/O
drawers supported can vary.
Table 1-11 summarizes the maximum number of I/O drawers supported and the total number
of PCI slots available when expansion consists of a single drawer type.
Table 1-11 Maximum number of I/O drawers supported and total number of PCI slots
Table 1-12 summarizes the maximum number of disk only I/O drawers supported .
Table 1-12 Maximum number of disk only I/O drawers supported
1.6.5 EXP 12S SAS Drawer
The EXP 12S SAS drawer (#5886) is a 2 EIA drawer and mounts in a 19-inch rack. The
drawer can hold either SAS disk drives or SSD. The EXP 12S SAS drawer has twelve
3.5-inch SAS disk bays with redundant data paths to each bay. The SAS disk drives or SSDs
contained in the EXP12S are controlled by one or two PCIe or PCI-X SAS adapters
connected to the EXP12S via SAS cables.
Note: IBM i does not support the 7314-G30 I/O drawer.
Server Processor
cards
Max
#5796
drawers
Max #5802
and #5877
drawersa
Total number of slots
#5796 #5802 and #5877
PCI-X PCIe PCI-X PCIe
Power 720 one 4 2 24 8a
a. Four additional slots are low profile PCIe slots only.
0 28a
Power 740 one 4 2 24 8a
0 28a
Power 740 two 8 4 48 8a
0 48a
Server Processor
cards
Max #5886
drawers
Max #5887
drawers
Max #7314-G30
drawers
Power 720 one 28 14 4
Power 740 one 28 14 4
Power 740 two 28 14 8
Note: The Power 720 4-core model does not support the 12X I/O drawer.
Chapter 1. General description 17
The feature 5886 can also be directly attached to the SAS port on the rear of the Power 720,
providing a very low cost disk storage solution. When used this way, the imbedded SAS
controllers in the system unit drive the disk drives in EXP12S. A second unit cannot be
cascaded to a feature 5886 attached in this way.
1.6.6 EXP 24S SFF Gen2-bay Drawer
The EXP24S SFF Gen2-bay Drawer is an expansion drawer with twenty-four 2.5- inch form
factor (SFF) SAS bays. It supports up to 24 hot-swap SFF SAS HDDs on POWER6 or
POWER7 servers in 2U of 19-inch rack space. The EXP24S bays are controlled by SAS
adapters/controllers attached to the I/O drawer by SAS X or Y cables.
The SFF bays of the EXP24S are different from the SFF bays of the POWER7 system units
or 12X PCIe I/O Drawers (#5802, #5803). The EXP24S uses Gen-2 or SFF-2 SAS drives
that physically do not fit in the Gen-1 or SFF-1 bays of the POWER7 system unit or 12X
PCIe I/O Drawers or vice versa
1.7 Comparison between models
The Power 720 and Power 740 offers a variety of configuration options where the POWER7
processor has 4-cores at 3.0, 3.3, or 3.7 GHz, 6-cores at 3.0 or 3.7 GHz, or 8-cores at 3.0 or
3.55 GHz.
The POWER7 processor has 4 MB of on-chip L3 cache per core. For the 4-core version there
is 16 MB, for the 6-core version there is 24 MB of L3 cache available, whereas for the 8-core
version there is 32 MB of L3 cache available.
Table 1-13 summarizes the various processor core options and frequencies and matches
them to the L3 cache sizes.
Table 1-13 Summary of processor core counts, core frequencies, and L3 cache sizes
1.8 Build to Order
You can perform a Build to Order or a la carte configuration using the IBM Configurator for
e-business (e-config) where you specify each configuration feature that you want on the
system. You build on top of the base required features, such as the embedded Integrated
Virtual Ethernet adapter.
System Cores per
POWER7 chip
Frequency
(GHz)
L3 Cache per
POWER7 chip
Min/Max cores
per system
Power 720 4 3.0 16 MB 4
Power 720 6 3.0 24 MB 6
Power 720 8 3.0 32 MB 8
Power 740 4 3.3 16 MB 4-8
Power 740 4 3.7 16 MB 4-8
Power 740 6 3.7 24 MB 6-12
Power 740 8 3.55 32 MB 16
18 IBM Power 720 and 740: Technical Overview and Introduction
Preferably, begin with one of the available starting configurations, such as the IBM Editions.
These solutions are available at initial system order time with a starting configuration that is
ready to run as is.
1.9 IBM Editions
IBM Editions are available only as initial order.
If you order a server IBM Edition as defined next, you can qualify for half the initial
configuration's processor core activations at no additional charge.
The total memory (based on the number of cores) and the quantity/size of disk, SSD, Fibre
Channel adapters, or Fibre Channel over Ethernet (FCoE) adapters shipped with the server
are the only features that determine if a customer is entitled to a processor activation at no
additional charge.
When you purchase an IBM Edition, you can purchase an AIX, IBM i, or Linux operating
system license, or you can choose to purchase the system with no operating system. The
AIX, IBM i, or Linux operating system is processed by means of a feature code on AIX 5.3 or
6.1, or 7.1; IBM i 6.1.1 or IBM i 7.1; and SUSE Linux Enterprise Server or Red Hat Enterprise
Linux. If you choose AIX 5.3, 6.1, or 7.1 for your primary operating system, you can also order
IBM i 6.1.1 or IBM i 7.1 and SUSE Linux Enterprise Server or Red Hat Enterprise Linux. The
converse is true if you choose an IBM i or Linux subscription as your primary operating
system.
These sample configurations can be changed as needed and still qualify for processor
entitlements at no additional charge. However, selection of total memory or HDD or
SSD/Fibre Channel/FCoE adapter quantities smaller than the totals defined as the minimums
disqualifies the order as an IBM Edition, and the no-charge processor activations are then
removed.
Consider the following minimum definitions for IBM Editions:
For Power 720, a minimum of 2 GB memory per core is needed to qualify for the IBM
Edition, except on the 6-core IBM Edition, where effectively there is a 16 GB minimum
memory requirement. For example, a 2-core minimum is 8 GB, a 6-core minimum is
16 GB, and an 8-core minimum is 16 GB. There can be other valid memory configurations
that meet the minimum requirement. However, the 1 x 16 GB feature (#4529) is not
supported. This feature must always be ordered in pairs.
For the Power 740, a minimum of 4 GB memory per core is needed to qualify for the IBM
Edition, except on the 6-core IBM Edition where there is effectively a 32 GB minimum
memory requirement. For example, a 4-core minimum is 16 GB, a 6-core minimum is
32 GB, an 8-core minimum is 32 GB, and a 16-core is 64 GB. There can be other valid
memory configurations that meet the minimum requirement. However, 1 x 16 GB feature
(#4529) is not supported. This feature must always be ordered in pairs.
Also, a minimum of two HDD, or two SSD, or two Fibre Channel adapters, or two FCoE
adapters are required. You only need to meet one of these disk/SSD/FC/FCoE criteria. Partial
criteria cannot be combined.
1.9.1 Express editions for IBM i
Express editions for IBM i enable initial ease of ordering and feature a lower price than if you
ordered them a la carte or build-to-order. Taking advantage of the edition is the only way you
Chapter 1. General description 19
can use no-charge features for processor activations and IBM i user license entitlements. The
Express editions are available only during the initial system order and cannot be ordered after
your system is shipped.
The IBM configurator offers these easy-to-order Express editions that include no-charge
activations or no-charge IBM i user entitlements. You can modify the Express Edition
configurations to match your exact requirements for your initial shipment by increasing or
decreasing the configuration. If you create a configuration that falls below any of the defined
minimums, the IBM configurator replaces the no-charge features with equivalent function
regular charge features.
1.9.2 Express editions for Power 720
In order to configure a Power 720 4-core Express Edition for IBM i (#0774) and use the
no-charge features on your initial order, you must order the following components:
3.0 GHz 4-core processor module (#8350)
IBM i Primary Operating System Indicator (#2145)
8 GB minimum memory - 1 x 8 GB (2 x 4 GB DIMMs) (#4526)
A minimum of two HDDs, or two SSDs, or two Fibre Channel adapters, or two FCoE
adapters. You only need to meet one of these disk/SSD/FC/FCoE criteria. Partial criteria
cannot be combined.
If the foregoing requirements are met, the following features are included:
Two no-charge activations (2 x #8363)
IBM i 5 user entitlements (no-charge)
One IBM i Access Family license with unlimited users (57xx-XW1)
Reduced price on 57xx-WDS and 5733-SOA
For a Power 720 6-, 8-core Express Edition for IBM i (#0778) configuration in combination
with the no-charge features on your initial order, you must order:
3.0 GHz 6-core processor module (#8351) or 3.0 GHz 8-core processor module (#8352)
IBM i Primary Operating System Indicator (#2145)
16 GB minimum memory - 2 x 8 GB (2 x 4 GB DIMMs) (#4526) or 2 x 16 GB (2 x 8 GB
DIMMs) (#4529)
A minimum of two HDDs, or two SSDs, or two Fibre Channel adapters, or two FCoE
adapters. You only need to meet one of these disk/SSD/FC/FCoE criteria. Partial criteria
cannot be combined.
If the foregoing requirements are met, the following features are included:
Three no-charge activations (3 x #8364) with #8351 or four no-charge activations
(4 x #8365) with #8352
Six activations, 3 x #8361 (chargeable) and 3 x #8364 (no-charge), with 6-core #8351
IBM i 30 user entitlements (charged)
One IBM i Acces?s Family license with unlimited users (57xx-XW1)
Reduced price on 57xx-WDS and 5733-SOA
Note: Memory feature #4529 is not supported with the 4-core processor module.
20 IBM Power 720 and 740: Technical Overview and Introduction
1.10 IBM i Solution Edition for Power 720 and Power 740
The IBM i Solution Editions for Power 720 and Power 740 are designed to help you take
advantage of the combined experience and expertise of IBM and independent software
vendors (ISVs) in building business value with your IT investments. A qualifying purchase of
software, maintenance, services or training for a participating ISV solution is required when
purchasing an IBM i Solution Edition.
The Power 720 Solution edition (#4971) supports both 6-core and 8-core configurations. For
a list of participating ISVs, registration form and additional details, visit the Solution Edition
website:
http://www-03.ibm.com/systems/power/hardware/editions/solutions.html
The Power 720 Solution Edition includes no-charge features resulting in a lower initial list
price for qualifying clients. Also included is an IBM Service voucher to help speed
implementation of the ISV solution.
The Power 740 Solution edition supports all processor configurations. For a list of
participating ISVs, registration form and additional details, visit the Solution Edition website:
http://www-03.ibm.com/systems/power/hardware/editions/solutions.html
The Power 740 Solution Edition includes no-charge features resulting in a lower initial list
price for qualifying clients. Also included is an IBM Service voucher to help speed
implementation of the ISV solution.
The requirements to be eligible to purchase a Solution Edition order are as follows:
The offering must include new and/or upgrade software licenses and/or software
maintenance from the ISV for the qualifying IBM server. Services and/or training for the
qualifying server can also be provided.
Proof of purchase of the solution with a participating ISV must be provided to IBM on
request. The proof must be dated within 90 days before or after the date of order of the
qualifying server.
Note: The Power 740 does not have an Express Edition for the IBM i feature code
available.
Chapter 1. General description 21
1.11 Model upgrade
Clients can upgrade from a Power 520 to the Power 720, preserving the existing serial
number. You can upgrade the Power 520 server (8203-E4A) into the Power 720 (8202-E4B).
The 9408-M25 needs first to be converted to a Power 520 (8203-E4A) and then upgraded to
Power 720.
The upgrade will not produce a lower-priced hardware configuration compared to a new
server with a new serial number. However, the upgrade will keep the same licensing in place
for AIX and IBM i. Retaining the IBM i licensing can be a very significant advantage. Feature
conversions are used to help identify the components that are returned to IBM with the
upgrade.
1.11.1 Upgrade considerations
Feature conversions have been set up for the following processors:
IBM POWER6® and IBM POWER6+™ processors to POWER7 processors
Table 1-14 shows conversions for the processors.
Table 1-14 Processor conversions
1.11.2 Features
The following features present on the current system can be moved to the new system:
PCIe adapters with cables
Line cords, keyboards, and displays
PowerVM (#5525, #5227, #5228)
I/O drawers (#5786, #5796, #5802, #5877, and #5886)
Racks (#0551, #0553, and #0555)
Rack doors (#6068, #6069, #6248, and #6249)
Power 520 Power 720
#5634 2-core 4.2 GHz Processor Card #8351 6-core 3.0 GHz POWER7 Processor Module
#5577 2-core 4.7 GHz Processor Card #8351 6-core 3.0 GHz POWER7 Processor Module
#5578 One Processor Activation for
Processor Feature #5577
#8351 6-core 3.0 GHz POWER7 Processor Module
#5634 2-core 4.2 GHz Processor Card #8352 8-core 3.0 GHz POWER7 Processor Module
#5577 2-core 4.7 GHz Processor Card #8352 8-core 3.0 GHz POWER7 Processor Module
#5578 One Processor Activation for
Processor Feature #5577
#8352 8-core 3.0 GHz POWER7 Processor Module
Notes:
The POWER6 processor module feature has two or four cores and a POWER7
processor has six or eight cores. The conversion pricing takes this core difference into
consideration. Also note that all processor activation features will have to be added.
Priced (#8361 and #8362) and zero-priced (#8364 and #8365) processor activations
will be applied according to the IBM Edition qualification rules.
22 IBM Power 720 and 740: Technical Overview and Introduction
Rack trim kits (#6246 and 6247)
SATA DVD-ROM (#5743)
SATA DVD-RAM (#5762)
The Power 720 can support the following 12X drawers and disk-only drawers:
#5802 and #5877 PCIe 12X I/O drawers
#5796 and 7413-G30 PCI-X (12X) I/O Drawer
#5786 and 7031-D24 IBM TotalStorage® EXP24 SCSI Disk Drawer
#5886 EXP12S SAS Disk Drawer
#5887 EXP 24S SFF Gen2-bay Drawer
It is important to summarize other key points beyond I/O drawers:
15k rpm SCSI drives that are 69 GB, or higher, are supported (10k rpm SCSI or 15k rpm
SCSI drives of less than 69 GB are not supported).
All SAS disk drives supported on the POWER6 rack/tower servers are supported.
Quarter Inch Cartridge (QIC) tape drives are not supported. Many newer, faster,
larger-capacity replacement options are available.
IBM i IOPs are not supported, which impacts any older PCI adapters that require an IOP.
This can impact older I/O devices such as tape libraries or optical drive libraries or any
HVD SCSI device. It means twinax displays/printers cannot be attached except by an
OEM protocol converter. It means SDLC-attached devices using a LAN/WAN adapter are
not supported. SNA applications still can run when encapsulated inside TCP/IP, but the
physical device attachment cannot be SNA. It means that the earlier Fibre Channel and
SCSI controllers that depended upon an IOP being present are not supported.
1.12 Hardware Management Console models
If you want to implement partitions, a Hardware Management Console (HMC) or the
Integrated Virtualization Manager (IVM) or the new released IBM Systems Director
Management Console (SDMC) is required to manage the Power 720 and Power 740 servers.
Multiple POWER6 and POWER7 processor-based servers can be supported by a single
HMC or SDMC.
If an HMC is used to manage any POWER7 processor-based server, the HMC must be a
rack-mount model CR3, or later, or tower model C05, or later.
The HMC provides a set of functions that are necessary to manage the system, for example:
Creating and maintaining a multiple partition environment
Displaying a virtual operating system session terminal for each partition
Displaying a virtual operator panel for each partition
Detecting, reporting, and storing changes in hardware conditions
Powering managed systems on and off
Note: In the Power 720 system unit SAS bays, only the SAS SFF hard disks or SFF
solid-state drives are supported internally. The 3.5-inch HDD or SSD can be attached to
the Power 720 but must be located in a EXP 12S drawer (#5886).
Note: If you do not use an HMC or IVM or SDMC, the Power 720 and Power 740 runs in
full system partition mode, meaning that a single partition owns all the server resources
and only one operating system can be installed.
Chapter 1. General description 23
Acting as a service focal point for service representatives to determine an appropriate
service strategy
Several HMC models are supported to manage POWER7 based systems. At the time of
writing, four models (7042-C07, 7042-C08, 7042-CR5, and 7042-CR6) are available for
ordering, but you can also use the withdrawn models listed in Table 1-15.
Table 1-15 HMC models supporting POWER7 processor technology based servers
For the IBM Power 720 and IBM Power 740 the Licensed Machine Code Version 7 Revision
720 is required.
Existing HMC models 7310 can be upgraded to Licensed Machine Code Version 7 to support
environments that can include IBM POWER5™, IBM POWER5+™, POWER6, and POWER7
processor-based servers. Licensed Machine Code Version 6 (#0961) is not available for 7042
HMCs.
When IBM Systems Director is used to manage an HMC, or if the HMC manages more than
254 partitions, the HMC must have 3 GB of RAM minimum and be a rack-mount CR3, or later,
or deskside C06, or later, deskside.
IBM SDMC
The SDMC is intended to be used in the same manner as the HMC. It provides the same
functionality, including hardware, service, and virtualization management, for your Power
Systems server and Power Systems blades. Because SDMC uses IBM Systems Director
Express® Edition, it also provides all Systems Director Express capabilities, such as
monitoring of operating systems and creating event action plans.
Much of the SDMC function is equivalent to the HMC. This includes:
Server (host) management
Virtualization management
Transition of configuration data: no configuration changes are required when a client
moves from HMC management to SDMC management.
Type-model Availability Description
7310-C05 Withdrawn IBM 7310 Model C05 Desktop Hardware Management Console
7310-C06 Withdrawn IBM 7310 Model C06 Deskside Hardware Management Console
7042-C06 Withdrawn IBM 7042 Model C06 Deskside Hardware Management Console
7042-C07 Available IBM 7042 Model C07 Deskside Hardware Management Console
7042-C08 Available IBM 7042 Model C08 Deskside Hardware Management Console
7310-CR3 Withdrawn IBM 7310 Model CR3 Rack-mounted Hardware Management Console
7042-CR4 Withdrawn IBM 7042 Model CR4 Rack-mounted Hardware Management Console
7042-CR5 Available IBM 7042 Model CR5 Rack-mounted Hardware Management Console
7042-CR6 Available IBM 7042 Model CR6 Rack-mounted Hardware Management Console
Note: You can download or order the latest HMC code from the Fix Central website:
http://www.ibm.com/support/fixcentral
24 IBM Power 720 and 740: Technical Overview and Introduction
Redundancy and high availability: The SDMC offers console redundancy similar to the
HMC
In most cases, the scalability and performance of SDMC matches that of a current HMC. This
includes both the number of systems (hosts) and the number of partitions (virtual servers)
that can be managed. Currently, 48 small-tier entry servers or 32 large-tier servers can be
managed by the SDMC with up to 1,024 partitions (virtual servers) configured across those
managed systems (hosts).
The SDMC can be obtained as a hardware appliance-in the same manner as an HMC.
Hardware appliances support managing all Power Systems servers. The SDMC can
optionally be obtained in a virtual appliance format, capable of running on VMware (ESX/i 4,
or later), and KVM (Red Hat Enterprise Linux® (RHEL) 5.5). The virtual appliance is only
supported or managing small-tier Power® servers and Power Systems blades.
Table 1-16 and Table 1-17 detail whether the SDMC software appliance, hardware appliance,
or both are supported for each model.
Table 1-16 Type of SDMC appliance support for POWER7 based server
Table 1-17 Type of SDMC appliance support for POWER6 based server
POWER7 models Type of SDMC appliance supported
7891-73X, 7891-74X PS703, PS704 Hardware or software appliance
8202-E4B (IBM Power 720 Express®) Hardware or software appliance
8205-E6B (IBM Power 740 Express) Hardware or software appliance
8406-70Y PS700 Hardware or software appliance
8406-71Y PS701,702 Hardware or software appliance
8231-E2B (IBM Power 710 and IBM Power 730 Express) Hardware or software appliance
8233-E8B (IBM Power 750 Express) Hardware or software appliance
8236-E8C (IBM Power 755) Hardware or software appliance
9117-MMB (IBM Power 770) Hardware appliance only
9119-FHB (IBM Power 795) Hardware appliance only
9179-MHB (IBM Power 780) Hardware appliance only
POWER6 models Type of SDMC appliance supported
7778-23x JS23 Hardware or software appliance
7998-60X JS12 Hardware or software appliance
7998-61X JS22 Hardware or software appliance
8203-E4A (Power 520 Express) Hardware or software appliance
8204-E8A (Power 550 Express) Hardware or software appliance
8234-EMA (Power 560 Express) Hardware appliance only
8261-E4S (IBM Smart Cubes) Hardware or software appliance
9406-MMA (Power 570) Hardware appliance only
9407-M15 (Power 520 Express) Hardware or software appliance
Chapter 1. General description 25
The IBM SDMC Hardware Appliance requires:
An IBM 7042 Rack-mounted Hardware Management Console and IBM SDMC indicator
(#0963).
The IBM SDMC Virtual Appliance requires:
IBM Systems Director Management Console V6.7.3 (5765-MCV)
SDMC on Power Systems POWER6 processor-based servers and blades requires
eFirmware level 3.5.7. SDMC on Power Systems POWER7 processor-based servers and
blades requires eFirmware level 7.3.0.
1.13 System racks
•The Power 720 and Power 740 and its I/O drawers are designed to mount in the 25U
7014-S25 (#0555), 36U 7014-T00 (#0551), or the 42U 7014-T42 (#0553) rack. These racks
are built to the 19-inch EIA standard.?
9408-M25 (Power 520 Express) Hardware or software appliance
9409-M50 (Power 550 Express) Hardware or software appliance
9117-MMA (Power 570) Hardware appliance only
9119-FHA (Power 595) Hardware appliance only
9125-F2A (Power 575) Hardware appliance only
Note: When ordering #0963, you must also order features #0031(No Modem) , #1946
(additional 4GB (2X2GB), 1.333GHz DDR3) and #1998 (additional 500GB SATA HDD).
Feature # 0963 replaces the HMC software with IBM Systems Director Management
Console Hardware Appliance V6.7.3 (5765-MCH).
Neither an external modem (#0032) nor an internal modem (#0033) may be selected with
IBM SDMC (#0963).
To run HMC LMC (#0962), you cannot order the additional storage (#1998); however, you
can order the additional memory (#1946) if wanted.
Note: For the software appliance, customer is responsible for providing the hardware and
and virtualization environment.
At a minimum, the following resources should be available to the virtual machine:
2.53 GHz Intel Xeon E5630, Quad Core processor
500 MB storage
6 GB memory
The hypervisors supported are:
VMware (ESX/i 4.0, or later)
KVM (RHEL 5.5)
POWER6 models Type of SDMC appliance supported
26 IBM Power 720 and 740: Technical Overview and Introduction
If a system is to be installed in a non-IBM rack or cabinet, ensure that the rack meets the
requirements that are described in 1.13.10, “OEM rack” on page 32.
1.13.1 IBM 7014 Model S25 rack
The 1.3 Meter (49-inch) Model S25 rack has the following features:
25 EIA units
Weights:
– Base empty rack: 100.2 kg (221 lb.)
– Maximum load limit: 567.5 kg (1250 lb.)
The S25 racks do not have vertical mounting space that will accommodate #7188 PDUs. All
PDUs required for application in these racks must be installed horizontally in the rear of the
rack. Each horizontally mounted PDU occupies 1U of space in the rack, and therefore
reduces the space available for mounting servers and other components.
1.13.2 IBM 7014 Model T00 rack
The 1.8 Meter (71-in.) Model T00 is compatible with past and present IBM Power systems.
The T00 rack has the following features:
It has 36 EIA units (36 U) of usable space.
The following optional features are available:
– Optional removable side panels.
– Optional highly perforated front door.
– Optional side-to-side mounting hardware for joining multiple racks.
You have a choice of standard business black or optional white color in OEM format.
Increased power distribution and weight capacity is provided.
Support for both ac and dc configurations is included.
The rack height is increased to 1926 mm (75.8 in.) if a power distribution panel is fixed to
the top of the rack.
Up to four power distribution units (PDUs) can be mounted in the PDU bays (Figure 1-4 on
page 28), but others can fit inside the rack. See 1.13.7, “The ac power distribution unit and
rack content” on page 27.
Weights are as follows:
– T00 base empty rack: 244 kg (535 lb.)
– T00 full rack: 816 kg (1795 lb.)
Note: A new Power 720 or Power 740 server is ordered with the appropriate 7014 rack
model. The racks are available as features of the Power 720 and Power 740 only when an
additional I/O drawer for an existing system (MES order) is ordered. The rack feature
number must be used if IBM manufacturing has to integrate the newly ordered I/O drawer
in a 19-inch rack before shipping the MES order.
Note: It is the client’s responsibility to ensure that the installation of the drawer in the
preferred rack or cabinet results in a configuration that is stable, serviceable, safe, and
compatible with the drawer requirements for power, cooling, cable management, weight,
and rail security.
Chapter 1. General description 27
1.13.3 IBM 7014 Model T42 rack
The 2.0 meter (79.3-inch) Model T42 addresses the client requirement for a tall enclosure to
house the maximum amount of equipment in the smallest possible floor space. The following
features differ in the Model T42 rack from the Model T00:
There are 42 EIA units (42 U) of usable space (6 U of additional space).
The Model T42 supports ac only.
Rack weights are as follows:
– T42 base empty rack: 261 kg (575 lb.)
– T42 full rack: 930 kg (2045 lb.)
1.13.4 Feature code 0555 rack
The 1.3 meter rack (#0555) is a 25 EIA unit rack. The rack that is delivered as #0555 is the
same rack delivered when you order the 7014-S25 rack; the included features can vary. The
#0555 is supported, but no longer orderable.
1.13.5 Feature code 0551 rack
The 1.8 meter rack (#0551) is a 36 EIA unit rack. The rack that is delivered as #0551 is the
same rack delivered when you order the 7014-T00 rack; the included features can vary.
Certain features that are delivered as part of the 7014-T00 must be ordered separately with
the #0551.
1.13.6 Feature code 0553 rack
The 2.0 meter rack (#0553) is a 42 EIA unit rack. The rack that is delivered as #0553 is the
same rack delivered when you order the 7014-T42 or B42 rack; the included features can
vary. Some features that are delivered as part of the 7014-T42 or B42 must be ordered
separately with the #0553.
1.13.7 The ac power distribution unit and rack content
For rack models T00 and T42, 12-outlet PDUs are available. These include ac power
distribution units #9188 and #7188 and ac Intelligent PDU+ #5889 and #7109.
Four PDUs can be mounted vertically in the back of the T00 and T42 racks. See Figure 1-4
on page 28 for the placement of the four vertically mounted PDUs. In the rear of the rack, two
additional PDUs can be installed horizontally in the T00 rack and three in the T42 rack. The
four vertical mounting locations will be filled first in the T00 and T42 racks. Mounting PDUs
horizontally consumes 1U per PDU and reduces the space available for other racked
components. When mounting PDUs horizontally, it is best to use fillers in the EIA units
occupied by these PDUs to facilitate proper air-flow and ventilation in the rack.
28 IBM Power 720 and 740: Technical Overview and Introduction
Figure 1-4 PDU placement and PDU view
For detailed power cord requirements and power cord feature codes, see the IBM Power
Systems Hardware Information Center at the following website:
http://publib.boulder.ibm.com/infocenter/systems/scope/hw/index.jsp
The Intelligent PDU+, base option, 1 EIA Unit, Universal, UTG0247 Connector (#5889), the
Base/Side Mount Universal PDU (#9188) and the optional, additional, Universal PDU (#7188)
and the Intelligent PDU+ options (#7109) support a wide range of country requirements and
electrical power specifications. The #5889 and #7109 PDUs are identical to #9188 and #7188
PDUs but are equipped with one Ethernet port, one console serial port, and one rs232 serial
port for power monitoring.
The PDU receives power through a UTG0247 power line connector. Each PDU requires one
PDU-to-wall power cord. Various power cord features are available for various countries and
applications by varying the PDU-to-wall power cord, which must be ordered separately. Each
power cord provides the unique design characteristics for the specific power requirements. To
match new power requirements and save previous investments, these power cords can be
requested with an initial order of the rack or with a later upgrade of the rack features.
The PDU has 12 client-usable IEC 320-C13 outlets. There are six groups of two outlets fed by
six circuit breakers. Each outlet is rated up to 10 amps, but each group of two outlets is fed
from one 15 amp circuit breaker.
Note: Ensure that the appropriate power cord feature is configured to support the power
being supplied.
Chapter 1. General description 29
The Universal PDUs are compatible with previous models.
1.13.8 Rack-mounting rules
Follow these primary rules when mounting the system into a rack:
The system is designed to be placed at any location in the rack. For rack stability, it is
advisable to start filling a rack from the bottom.
Any remaining space in the rack can be used to install other systems or peripherals,
provided that the maximum permissible weight of the rack is not exceeded and the
installation rules for these devices are followed.
Before placing the system into the service position, it is essential that the rack
manufacturer’s safety instructions have been followed regarding rack stability.
1.13.9 Useful rack additions
This section highlights solutions available for IBM Power Systems rack-based systems.
IBM System Storage 7214 Tape and DVD Enclosure
The IBM System Storage® 7214 Tape and DVD Enclosure is designed to mount in one EIA
unit of a standard IBM Power Systems 19-inch rack and can be configured with one or two
tape drives, or either one or two Slim DVD-RAM or DVD-ROM drives in the right-side bay.
The two bays of the IBM System Storage 7214 Tape and DVD Enclosure can accommodate
the following tape or DVD drives for IBM Power servers:
DAT72 36 GB Tape Drive - up to two drives
DAT72 36 GB Tape Drive - up to two drives
DAT160 80 GB Tape Drive - up to two drives
Half-high LTO Ultrium 4 800 GB Tape Drive - up to two drives
DVD-RAM Optical Drive - up to two drives
DVD-ROM Optical Drive - up to two drives
Note: Based on the power cord that is used, the PDU can supply from 4.8 kVA to 19.2 kVA.
The power of all the drawers plugged into the PDU must not exceed the power cord
limitation.
Note: Each system drawer to be mounted in the rack requires two power cords, which are
not included in the base order. For maximum availability, it is highly desirable to connect
power cords from the same system to two separate PDUs in the rack, and to connect each
PDU to independent power sources.
30 IBM Power 720 and 740: Technical Overview and Introduction
IBM System Storage 7216 Multi-Media Enclosure
The IBM System Storage 7216 Multi-Media Enclosure (Model 1U2) is designed to attach to
the Power 720 and the Power 740 through a USB port on the server, or through a PCIe SAS
adapter. The 7216 has two bays to accommodate external tape, removable disk drive, or
DVD-RAM drive options.
The following optional drive technologies are available for the 7216-1U2:
DAT160 80 GB SAS Tape Drive (#5619
DAT320 160 GB SAS Tape Drive (#1402)
DAT320 160 GB USB Tape Drive (#5673)
Half-high LTO Ultrium 5 1.5 TB SAS Tape Drive (#8247)
DVD-RAM - 9.4 GB SAS Slim Optical Drive (#1420 and 1422
RDX Removable Disk Drive Docking Station (#1103)
In order to attach a 7216 Multi-Media Enclosure to the Power 720 and Power 740, consider
the following cabling procedures:
Attachment by an SAS adapter:
A PCIe Dual-X4 SAS adapter (#5901) or a PCIe LP 2-x4-port SAS Adapter 3Gb (#5278)
must be installed in the Power 720 and Power 740 server in order to attach to a 7216
Model 1U2 Multi-Media Storage Enclosure. Attaching a 7216 to a Power 720 and
Power 740 through the integrated SAS adapter is not supported.
For each SAS tape drive and DVD-RAM drive feature installed in the 7216, the appropriate
external SAS cable will be included.
An optional Quad External SAS cable is available by specifying (#5544) with each 7216
order. The Quad External Cable allows up to four 7216 SAS tape or DVD-RAM features
to attach to a single System SAS adapter.
Up to two 7216 storage enclosure SAS features can be attached per PCIe Dual-X4 SAS
adapter (#5901) or the PCIe LP 2-x4-port SAS Adapter 3Gb (#5278).
Attachment by an USB adapter:
The Removable RDX HDD Docking Station features on 7216 only support the USB cable
that is provided as part of the feature code. Additional USB hubs, add-on USB cables, or
USB cable extenders are not supported.
For each RDX Docking Station feature installed in the 7216, the appropriate external USB
cable will be included. The 7216 RDX Docking Station feature can be connected to the
external, integrated USB ports on the Power 710 and Power 730 or to the USB ports on
4-Port USB PCI Express® Adapter (# 2728).
The 7216 DAT320 USB tape drive or RDX Docking Station features can be connected to
the external, integrated USB ports on the Power 710 and Power 730.
The two drive slots of the 7216 enclosure can hold the following drive combinations:
One tape drive (DAT160 SAS or Half-high LTO Ultrium 5 SAS) with second bay empty
Two tape drives (DAT160 SAS or Half-high LTO Ultrium 5 SAS) in any combination
One tape drive (DAT160 SAS or Half-high LTO Ultrium 5 SAS) and one DVD-RAM SAS
drive sled with one or two DVD-RAM SAS drives
Up to four DVD-RAM drives
Note: DAT320 160 GB SAS Tape Drive (#1402)and DAT320 160 GB USB Tape Drive
(#5673) No Longer Available as of July 15, 2011
Chapter 1. General description 31
One tape drive (DAT160 SAS or Half-high LTO Ultrium 5 SAS) in one bay, and one RDX
Removable HDD Docking Station in the other drive bay
One RDX Removable HDD Docking Station and one DVD-RAM SAS drive sled with one
or two DVD-RAM SAS drives in the right bay
Two RDX Removable HDD Docking Stations
Figure 1-5 shows the 7216 Multi-Media Enclosure.
Figure 1-5 7216 Multi-Media Enclosure
In general, the 7216-1U2 is supported by the AIX, IBM i, and Linux operating system,
however, the RDX Removable Disk Drive Docking Station and the DAT320 USB Tape Drive
are not supported with IBM i.
Flat panel display options
The IBM 7316 Model TF3 is a rack-mountable flat panel console kit consisting of a 17-inch
337.9 mm x 270.3 mm flat panel color monitor, rack keyboard tray, IBM Travel Keyboard,
support for IBM's Keyboard/Video/Mouse (KVM) switches, and language support. The IBM
7316-TF3 Flat Panel Console Kit offers the following features:
Slim, sleek, lightweight monitor design that occupies only 1U (1.75 inches) in a 19-inch
standard rack
A 17-inch, flat screen TFT monitor with truly accurate images and virtually no distortion
Ability to mount the IBM Travel Keyboard in the 7316-TF3 rack keyboard tray
Support for IBM's Keyboard/Video/Mouse (KVM) switches that provide control of as many
as 128 servers, and support of both USB and PS/2 server-side keyboard and mouse
connections
32 IBM Power 720 and 740: Technical Overview and Introduction
1.13.10 OEM rack
The system can be installed in a suitable OEM rack, provided that the rack conforms to the
EIA-310-D standard for 19-inch racks. This standard is published by the Electrical Industries
Alliance. For detailed information. see the IBM Power Systems Hardware Information Center:
http://publib.boulder.ibm.com/infocenter/systems/scope/hw/index.jsp
The key points mentioned are as follows:
The front rack opening must be 451 mm wide ± 0.75 mm (17.75 in. ± 0.03 in.), and the
rail-mounting holes must be 465 mm ± 0.8 mm (18.3 in. ± 0.03 in.) apart on center
(horizontal width between the vertical columns of holes on the two front-mounting flanges
and on the two rear-mounting flanges). See Figure 1-6 for a top view showing the
specification dimensions.
Figure 1-6 Top view of non-IBM rack specification dimensions
571mm (22.50 in.)
Drawer Rail
Mounting
Flanges
Back, No Door
494mm (19.45 in.)
Front, No Door
203mm (8.0 in.)
719mm (28.31 in.)
51mm (2.01 in.)
451mm (17.76 in.)
494mm (19.45 in.)
Chapter 1. General description 33
The vertical distance between the mounting holes must consist of sets of three holes
spaced (from bottom to top) 15.9 mm (0.625 in.), 15.9 mm (0.625 in.), and 12.67 mm
(0.5 in.) on center, making each three-hole set of vertical hole spacing 44.45 mm (1.75 in.)
apart on center. Rail-mounting holes must be 7.1 mm ± 0.1 mm (0.28 in. ± 0.004 in.) in
diameter. See Figure 1-7 for the top front specification dimensions.
Figure 1-7 Rack specification dimensions, top front view
Hole Diameter =
7.1 +/- 0.1mm
Rack Mounting Holes Center-to-Center
Rack Front Opening
450 +/- 0.75mm
465 +/- 0.8mm
EIAHoleSpacing
6.75mm min
15.9mm
15.9mm
12.7mm
15.9mm
15.9mm
12.7mm
6.75mm min
15.9mm
15.9mm
12.7mm
15.9mm
15.9mm
12.7mm
Top Front of Rack
34 IBM Power 720 and 740: Technical Overview and Introduction
© Copyright IBM Corp. 2010. All rights reserved. 35
Chapter 2. Architecture and technical
overview
This chapter discusses the overall system architecture represented by Figure 2-1 on page 36,
with its major components described in the following sections. The bandwidths that are
provided throughout the section are theoretical maximums used for reference.
The speeds shown are at an individual component level. Multiple components and application
implementation are key to achieving the best performance.
Always do the performance sizing at the application workload environment level and evaluate
performance using real-world performance measurements and production workloads.
2
36 IBM Power 720 and 740: Technical Overview and Introduction
Figure 2-1 Power 740 logic data flow
POWER7
chip 0
4- 6- or 8-cores
Memory
controller 0
GX1
DIMM #2 – P1-C18-C2
buffer
DIMM #4 – P1-C18-C4
D
C
B
A
Integrated Virtual
Ethernet ports
USB portsUSB ctrl
GX++ slot 2
GX++ slot 1
Hard
disk
2
Hard
disk
3
Hard
disk
1
PCIe slot 1 (short)
PCIe slot 2 (short)
PCIe slot 3 (short)
PCIe slot 4 (short)
GX++ connector 2
GX++ connector 1
2 HMC ports
2 SPCN ports
GX0
Service
Processor
Operator panel
Vital Product Data
smart chip
DIMM #8 – P1-C18-C10
buffer
DIMM #6 – P1-C18-C8
POWER7
chip 1
4- 6- or 8-cores
Memory
controller 0
D
C
B
A
23.2GBps
GX1
GX0
Hard
disk
4
Hard
disk
5
Hard
disk
6
SAS Controller
DASD and media backplane
DVD
Integrated Virtual
Ethernet ports
RAID Option
External SAS
Port
2 System ports
P5-IOC2
10 GBps
20 GBps
20 GBps
DIMM #3 – P1-C18-C3
DIMM #5 – P1-C18-C7
DIMM #1 – P1-C18-C1
DIMM #7 – P1-C18-C9
MemoryCard#1
DIMM #2 – P1-C17-C2
buffer
DIMM #4 – P1-C17-C4
DIMM #8 – P1-C17-C10buffer
DIMM #6 – P1-C17-C8
DIMM #3 – P1-C17-C3
DIMM #5 – P1-C17-C7
DIMM #1 – P1-C17-C1
DIMM #7 – P1-C17-C9
MemoryCard#2
DIMM #2 – P1-C16-C2
buffer
DIMM #4 – P1-C16-C4
DIMM #8 – P1-C16-C10
buffer
DIMM #6 – P1-C16-C8
DIMM #3 – P1-C16-C3
DIMM #5 – P1-C16-C7
DIMM #1 – P1-C16-C1
DIMM #7 – P1-C16-C9
MemoryCard#3
DIMM #2 – P1-C15-C2
buffer
DIMM #4 – P1-C15-C4
DIMM #8 – P1-C15-C10
buffer
DIMM #6 – P1-C15-C8
DIMM #3 – P1-C15-C3
DIMM #5 – P1-C15-C7
DIMM #1 – P1-C15-C1
DIMM #7 – P1-C15-C9
MemoryCard#4
PCIe slot 1 (short, LP)
PCIe slot 2 (short, LP)
PCIe slot 3 (short, LP)
PCIe slot 4 (short, LP)
P5-IOC2
(Optional
internal PCIe
expansion)
23.2GBps
23.2GBps
Chapter 2. Architecture and technical overview 37
2.1 The IBM POWER7 processor
The IBM POWER7 processor represents a leap forward in technology achievement and
associated computing capability. The multi-core architecture of the POWER7 processor has
been matched with innovation across a wide range of related technologies in order to deliver
leading throughput, efficiency, scalability, and RAS.
Although the processor is an important component in delivering outstanding servers,
many elements and facilities have to be balanced on a server in order to deliver maximum
throughput. As with previous generations of systems based on POWER processors, the
design philosophy for POWER7 processor-based systems is one of system-wide balance in
which the POWER7 processor plays an important role.
In many cases, IBM has been innovative in order to achieve required levels of throughput and
bandwidth. Areas of innovation for the POWER7 processor and POWER7 processor-based
systems include, but are not limited to, the following features:
On-chip L3 cache implemented in embedded dynamic random access memory (eDRAM)
Cache hierarchy and component innovation
Advances in memory subsystem
Advances in off-chip signalling
Exploitation of long-term investment in coherence innovation
The superscalar POWER7 processor design also provides a variety of other capabilities:
Binary compatibility with the prior generation of POWER processors
Support for PowerVM virtualization capabilities, including PowerVM Live Partition Mobility
to and from POWER6 and POWER6+ processor-based systems.
38 IBM Power 720 and 740: Technical Overview and Introduction
Figure 2-2 shows the POWER7 processor die layout with the major areas identified;
processor cores, L2 cache, L3 cache and chip interconnection, Symmetric Multi Processing
(SMP) links, and memory controllers.
Figure 2-2 POWER7 processor die with key areas indicated
2.1.1 POWER7 processor overview
The POWER7 processor chip is fabricated using the IBM 45 nm Silicon-On-Insulator (SOI)
technology using copper interconnect and implements an on-chip L3 cache using eDRAM.
The POWER7 processor chip has an area of 567 mm2
and is built using 1.2 billion
components (transistors). Eight processor cores are on the chip, each with 12 execution units,
256 KB of L2 cache, and access to 32 MB of shared on-chip L3 cache.
For memory access, the POWER7 processor includes two Double Data Rate 3 (DDR3)
memory controllers, each with four memory channels. To be able to scale effectively, the
POWER7 processor uses a combination of local and global SMP links with very high
coherency bandwidth and takes advantage of the IBM dual-scope broadcast coherence
protocol.
Chapter 2. Architecture and technical overview 39
Table 2-1 summarizes the technology characteristics of the POWER7 processor.
Table 2-1 Summary of POWER7 processor technology
2.1.2 POWER7 processor core
Each POWER7 processor core implements aggressive out-of-order (OoO) instruction
execution to drive high efficiency in the use of available execution paths. The POWER7
processor has an Instruction Sequence Unit that is capable of dispatching up to six
instructions per cycle to a set of queues. Up to eight instructions per cycle can be issued to
the Instruction Execution units.
The POWER7 processor has a set of twelve execution units:
2 fixed point units
2 load store units
4 double precision floating point units
1 vector unit
1 branch unit
1 condition register unit
1 decimal floating point unit
The following caches are tightly coupled to each POWER7 processor core:
Instruction cache: 32 KB
Data cache: 32 KB
L2 cache: 256 KB, implemented in fast SRAM
Technology POWER7 processor
Die size 567 mm2
Fabrication technology 45 nm lithography
Copper interconnect
Silicon-on-Insulator
eDRAM
Components 1.2 billion components/transistors offering the
equivalent function of 2.7 billion (for further details, see
2.1.6, “On-chip L3 cache innovation and Intelligent
Cache” on page 43)
Processor cores 8
Max execution threads per core/chip 4/32
L2 cache per core/chip 256 KB/2 MB
On-chip L3 cache per core/chip 4 MB/32 MB
DDR3 memory controllers 2
SMP design-point 32 sockets with IBM POWER7 processors
Compatibility With prior generation of POWER processor
40 IBM Power 720 and 740: Technical Overview and Introduction
2.1.3 Simultaneous multithreading
An enhancement in the POWER7 processor is the addition of the SMT4 mode to enable four
instruction threads to execute simultaneously in each POWER7 processor core. Thus, the
instruction thread execution modes of the POWER7 processor are as follows:
SMT1: Single instruction execution thread per core
SMT2: Two instruction execution threads per core
SMT4: Four instruction execution threads per core
Maximizing throughput
SMT4 mode enables the POWER7 processor to maximize the throughput of the processor
core by offering an increase in core efficiency. SMT4 mode is the latest step in an evolution of
multithreading technologies introduced by IBM. The diagram in Figure 2-3 shows the
evolution of simultaneous multithreading.
Figure 2-3 Evolution of simultaneous multi-threading
The various SMT modes offered by the POWER7 processor allow flexibility, enabling users to
select the threading mode that meets an aggregation of objectives such as performance,
throughput, energy use, and workload enablement.
Intelligent Threads
The POWER7 processor features Intelligent Threads that can vary based on the workload
demand. The system either automatically selects (or the system administrator can manually
select) whether a workload benefits from dedicating as much capability as possible to a single
thread of work, or if the workload benefits more from having capability spread across two or
four threads of work. With more threads, the POWER7 processor can deliver more total
capacity as more tasks are accomplished in parallel. With fewer threads, those workloads that
need very fast individual tasks can get the performance they need for maximum benefit.
Multi-threading Evolution
FX0
FX1
FP0
FP1
LS0
LS1
BRX
CRL
1995 Single thread out of order
FX0
FX1
FP0
FP1
LS0
LS1
BRX
CRL
1997 Hardware multi-thread
FX0
FX1
FP0
FP1
LS0
LS1
BRX
CRL
2003 2 Way SMT
FX0
FX1
FP0
FP1
LS0
LS1
BRX
CRL
2009 4 Way SMT
Chapter 2. Architecture and technical overview 41
2.1.4 Memory access
Each POWER7 processor chip has two DDR3 memory controllers, each with four memory
channels (enabling eight memory channels per POWER7 processor chip). Each channel
operates at 6.4 GHz and can address up to 32 GB of memory. Thus, each POWER7
processor chip is capable of addressing up to 256 GB of memory.
Figure 2-4 gives a simple overview of the POWER7 processor memory access structure.
Figure 2-4 Overview of POWER7 memory access structure
2.1.5 Flexible POWER7 processor packaging and offerings
The POWER7 processor forms the basis of a flexible compute platform and can be offered in
a number of guises to address differing system requirements.
The POWER7 processor can be offered with a single active memory controller with four
channels for servers where higher degrees of memory parallelism are not required.
Similarly, the POWER7 processor can be offered with a variety of SMP bus capacities that are
appropriate to the scaling-point of particular server models.
POWER7 Processor Chip
Advanced
Buffer ASIC
Chip
Memory
Controller
Advanced
Buffer ASIC
Chip
Memory
Controller
Core Core Core Core
Core Core Core Core
Dual Integrated DDR3 memory controllers
• High channel and DIMM utilization
• Advanced energy management
• RAS advances
Eight high-speed 6.4 GHz channels
• New low-power differential signalling
New DDR3 buffer chip architecture
• Larger capacity support (32 GB/core)
• Energy management support
• RAS enablement
DDR3 DRAMs
42 IBM Power 720 and 740: Technical Overview and Introduction
Figure 2-5 outlines the physical packaging options that are supported with POWER7
processors.
Figure 2-5 Outline of the POWER7 processor physical packaging
POWER7 processors have the unique ability to optimize to various workload types. For
example, database workloads typically benefit from very fast processors that handle high
transaction rates at high speeds. Web workloads typically benefit more from processors with
many threads that allow the breaking down of web requests into many parts and handle them
in parallel. POWER7 processors uniquely have the ability to provide leadership performance
in either case.
TurboCore mode
Users can choose to run selected servers in TurboCore mode. This mode uses four cores per
POWER7 processor chip with access to the entire 32 MB of L3 cache (8 MB per core) and at
a faster processor core frequency, which delivers higher performance per core, and might
save on software costs for those applications that are licensed per core.
MaxCore mode
MaxCore mode is for workloads that benefit from a higher number of cores and threads
handling multiple tasks simultaneously, taking advantage of increased parallelism. MaxCore
mode provides up to eight cores and up to 32 threads per POWER7 processor.
POWER7 processor 4-core and 6-core offerings
The base design for the POWER7 processor is an 8-core processor with 32 MB of on-chip L3
cache (4 MB per core). However, the architecture allows for differing numbers of processor
cores to be active; 4-cores or 6-cores, as well as the full 8-core version.
In most cases (MaxCore mode), the L3 cache associated with the implementation is
dependent on the number of active cores. For a 6-core version, this typically means that
6 x 4 MB (24 MB) of L3 cache is available. Similarly, for a 4-core version, the L3 cache
available is 16 MB.
Note: TurboCore is available on the Power 780 and Power 795.
Single Chip Organic
1 x Memory Controller
Local broadcast SMP links active
Single Chip Glass Ceramic
2 x Memory Controllers
Local broadcast SMP links active
Global broadcast SMP links active
Chapter 2. Architecture and technical overview 43
2.1.6 On-chip L3 cache innovation and Intelligent Cache
A breakthrough in material engineering and microprocessor fabrication has enabled IBM to
implement the L3 cache in eDRAM and place it on the POWER7 processor die. L3 cache is
critical to a balanced design, as is the ability to provide good signalling between the L3 cache
and other elements of the hierarchy such as the L2 cache or SMP interconnect.
The on-chip L3 cache is organized into separate areas with differing latency characteristics.
Each processor core is associated with a Fast Local Region of L3 cache (FLR-L3) but also
has access to other L3 cache regions as shared L3 cache. Additionally, each core can
negotiate to use the FLR-L3 cache associated with another core, depending on reference
patterns. Data can also be cloned to be stored in more than one core's FLR-L3 cache, again
depending on reference patterns. This Intelligent Cache management enables the POWER7
processor to optimize the access to L3 cache lines and minimize overall cache latencies.
Figure 2-6 shows the FLR-L3 cache regions for each of the cores on the POWER7 processor
die.
Figure 2-6 Fast local regions of L3 cache on the POWER7 processor
Innovation using eDRAM on the POWER7 processor die is significant for these reasons:
Latency improvement:
A six-to-one latency improvement occurs by moving the L3 cache on-chip compared to L3
accesses on an external (on-ceramic) ASIC.
Bandwidth improvement:
A 2x bandwidth improvement occurs with on-chip interconnect. Frequency and bus sizes
are increased to and from each core.
44 IBM Power 720 and 740: Technical Overview and Introduction
No off-chip driver or receivers:
Removing drivers or receivers from the L3 access path lowers interface requirements,
conserves energy, and lowers latency.
Small physical footprint:
The eDRAM L3 cache requires far less physical space than an equivalent L3 cache
implemented with conventional SRAM. IBM on-chip eDRAM uses only a third of the
components used in conventional SRAM which has a minimum of 6 transistors to
implement a 1-bit memory cell.
Low energy consumption:
The on-chip eDRAM uses only 20% of the standby power of SRAM.
2.1.7 POWER7 processor and Intelligent Energy
Energy consumption is an important area of focus for the design of the POWER7 processor
which includes Intelligent Energy features that help to dynamically optimize energy usage
and performance so that the best possible balance is maintained. Intelligent Energy features
such as EnergyScale work with IBM Systems Director Active Energy Manager™ to
dynamically optimize processor speed based on thermal conditions and system utilization.
2.1.8 Comparison of the POWER7 and POWER6 processors
Table 2-2 shows comparable characteristics between the generations of POWER7 and
POWER6 processors.
Table 2-2 Comparison of technology for the POWER7 processor and the prior generation
Feature POWER7 POWER6
Technology 45 nm 65 nm
Die size 567 mm2
341 mm2
Maximum cores 8 2
Maximum SMT threads per
core
4 threads 2 threads
Maximum frequency 4.25 GHz 5 GHz
L2 Cache 256 KB per core 4 MB per core
L3 Cache 4 MB of FLR-L3 cache per core
with each core having access to
the full 32 MB of L3 cache,
on-chip eDRAM
32 MB off-chip eDRAM ASIC
Memory support DDR3 DDR2
I/O Bus Two GX++ One GX++
Enhanced Cache Mode
(TurboCore)
Yes No
Sleep & Nap Modea
a. For more information about Sleep and Nap modes, see 2.18.1, “IBM EnergyScale technology”
on page 96.
Both Nap only
Chapter 2. Architecture and technical overview 45
2.2 POWER7 processor modules
The Power 720 and Power 740 server chassis house POWER7 processor modules that host
POWER7 processor sockets (SCM) and eight DDR3 memory DIMM slots for each processor
module.
The Power 720 server houses one processor module offering 4-core 3.0 GHz, 6-core
3.0 GHz, or 8-core 3.0 GHz configurations.
The Power 740 server houses one or two processor modules offering 4-core or 8-core 3.3
and 3.7 GHz, 6-core or 12-core 3.7 GHz, or 8- and 16-core 3.55 GHz configurations.
All off the installed processors must be activated.
2.2.1 Modules and cards
Figure 2-7 shows the system planar highlighting the POWER7 processor modules and the
memory riser cards.
Figure 2-7 POWER7 processor card shown in a Power 740 with processor module
Note: All POWER7 processors in the system must be the same frequency and have the
same number of processor cores. POWER7 processor types cannot be mixed within a
system.
Memory riser cards
POWER7 processor
modules
46 IBM Power 720 and 740: Technical Overview and Introduction
2.2.2 Power 720 and Power 740 systems
Power 720 and Power 740 systems support POWER7 processors with various core-counts.
Table 2-3 summarizes the POWER7 processor options for the Power 720 system.
Table 2-3 Summary of POWER7 processor options for the Power 720 system
Table 2-4 summarizes the POWER7 processor options for the Power 740 system.
Table 2-4 Summary of POWER7 processor options for the Power 740 system
Feature Cores per
POWER7
processor
Frequency
(GHz)
Processor activation Min/Max
cores per
system
Min/Max
processor
module
#8350 4 3.0 The 4-core 3.0 GHz requires
that four processor activation
codes are ordered, available as
4 x #8360 or 2 x #8360 and
2 x #8363
4/4 1/1
#8351 6 3.0 The 6-core 3.0 GHz requires
that six processor activation
codes be ordered, available as
6 x #8361 or 3 x #8361 and
3 x #8364
6/6 1/1
#8352 8 3.0 The 8-core 3.0 GHz requires
that eight processor activation
codes be ordered, available as
8 x #8362 or 4 x #8362 and
4 x #8365
8/8 1/1
Feature Cores per
POWER7
processor
Frequency
(GHz)
Processor activation Min/Max
cores per
system
Min/Max
processor
module
#8353 4 3.3 The 4-core 3.3 GHz requires
that four processor activation
codes are ordered, available as
4 x #8366 or 2 x #8366 and
2 x #8369
4/8 1/2
#8347 4 3.7 The 4-core 3.7 GHz requires
that four processor activation
codes are ordered, available as
4 x #8373 or 2 x #8373 and
2 x #8374
4/8 1/2
#8354 6 3.7 The 6-core 3.7 GHz requires
that six processor activation
codes are ordered, available as
6 x #8367 or 3 x #8367 and
3 x #8370
6/12 1/2
#8355 8 3.55 2 x of the 8 core 3.55 GHz
requires that 16 processor
activation codes are ordered,
available as 16 x #8368 or
8 x #8368 and 8 x#8371)
16 1/2
Chapter 2. Architecture and technical overview 47
2.3 Memory subsystem
The Power 720 is a one socket system supporting a single POWER7 processor module. The
server supports a maximum of 16 DDR3 DIMM slots, with eight DIMM slots included in the
base configuration and eight DIMM slots available with an optional memory riser card.
Memory features (two memory DIMMs per feature) supported are 8 GB and 16 GB running at
speeds of 1066 MHz. A system with the optional memory riser card installed has a maximum
memory of 128 GB.
The Power 740 is a two socket system supporting up to two POWER7 processor modules.
The server supports a maximum of 32 DDR3 DIMM slots, with 8 DIMM slots included in the
base configuration and 24 DIMM slots available with three optional memory riser cards.
Memory features (two memory DIMMs per feature) supported are 8 GB and 16 GB run at
speeds of 1066 MHz. A system with three optional memory riser cards installed has a
maximum memory of 256 GB.
2.3.1 Registered DIMM
Industry standard DDR3 Registered DIMM (RDIMM) technology is used to increase reliability,
speed, and density of memory subsystems.
2.3.2 Memory placement rules
The following memory options are orderable:
8 GB (2 x 4 GB) Memory DIMMs, 1066 MHz (#4526)
16 GB (2 x 8 GB) Memory DIMMs, 1066 MHz (#4529)
The minimum memory capacity for the Power 720 and Power 740 systems is 8 GB (2 x 4 GB
DIMMs). The maximum is memory supported on the Power 720 is shown in Table 2-5 and the
maximum memory supported on the Power 740 is shown in Table 2-6.
Table 2-5 Power 720 maximum memory
Table 2-6 Power 740 maximum memory
Processor cores One memory riser card Two memory riser cards
4-core 32 GB 64 GB
6-core
8-core
64 GB 128 GB
Note: A system with the 4-core processor module (#8350) does not support the 16 GB memory
feature #4529.
Processor cores One memory
riser card
Two memory
riser cards
Three memory
riser cards
Four memory
riser cards
1 x 4-core
1 x 6-core
1 x 8-core
64 GB 128 GB Not available Not available
2 x 4-core
2 x 6-core
2 x 8-core
64 GB 128 GB 192 GB 256 GB
48 IBM Power 720 and 740: Technical Overview and Introduction
Figure 2-8 shows the physical memory DIMM topology for the POWER7 processor card.
Figure 2-8 Memory DIMM topology for the Power 740
The memory-placement rules are as follows:
The base machine contains one memory riser card with eight DIMM sockets. Memory
features occupy two memory DIMM sockets.
One additional memory riser card feature (1 x #5604) with an additional eight DIMM
sockets is available when one processor module is installed in the system. For the
Power 740, three optional memory riser card features (3 x #5604) with an additional eight
DIMM sockets per feature are available when two processor modules are installed in the
system.
A system can be ordered with a single memory feature #4526. When adding additional
memory to a system with 1 x #4526, a second 1 x #4526 must be ordered, and then all
memory must be ordered in increments of 2 x #4526.
A system cannot be ordered with a single memory feature #4529. All #4529 memory must
be ordered in quantity of 2 x feature #4529.
Feature #4526 and feature #4529 are allowed on the same memory riser card as long as
memory DIMMs are installed in quads (2 x #4526 or 2 x #4529).
Note: DDR2 memory (used in POWER6 processor-based systems) is not supported in
POWER7 processor-based systems.
Memory
Card #1
DDR3 RDIMM Slot 2
DDR3 RDIMM Slot 4Port A
SN-A
Port B
DDR3 RDIMM Slot 1
DDR3 RDIMM Slot 3Port A
SN-B
Port B
DDR3 RDIMM Slot 2
DDR3 RDIMM Slot 4Port A
SN-C
Port B
DDR3 RDIMM Slot 1
DDR3 RDIMM Slot 3Port A
SN-D
Port B
Memory
Card #2
POWER7
MC0
Port 0
MC0
Port 1
MC0
Port 2
MC0
Port 3
Memory
Card #3
DDR3 RDIMM Slot 2
DDR3 RDIMM Slot 4Port A
SN-A
Port B
DDR3 RDIMM Slot 1
DDR3 RDIMM Slot 3Port A
SN-B
Port B
DDR3 RDIMM Slot 2
DDR3 RDIMM Slot 4Port A
SN-C
Port B
DDR3 RDIMM Slot 1
DDR3 RDIMM Slot 3Port A
SN-D
Port B
Memory
Card #4
POWER7
MC0
Port 0
MC0
Port 1
MC0
Port 2
MC0
Port 3
MC: Memory Controller
SN: Memory Buffer
Chapter 2. Architecture and technical overview 49
It is generally best to install memory evenly across all memory riser cards in the system.
Balancing memory across the installed memory riser cards allows memory access in a
consistent manner and typically results in the best possible performance for your
configuration. However, balancing memory fairly evenly across multiple memory riser cards,
compared to balancing memory exactly evenly, typically has a very small performance
difference.
Take into account any plans for future memory upgrades when deciding which memory
feature size to use at the time of initial system order.
Table 2-7 shows the installation slots for memory DIMMs for two POWER7 modules and four
memory cards.
Table 2-7 Memory DIMM installation sequence and slots
DIMM-pair Memory card DIMM slots
First One Slot 6 (P1-C18-C8)
Slot 8 (P1-C18-C10)
Second One Slot 5 (P1-C18-C7)
Slot 7 (P1-C18-C9)
Third
Fourth
Two Slot 5 (P1-C17-C7)
Slot 6 (P1-C17-C8)
Slot 7 (P1-C17-C9)
Slot 8 (P1-C17-C10)
Fifth
Sixth
Three Slot 5 (P1-C16-C7)
Slot 6 (P1-C16-C8)
Slot 7 (P1-C16-C9)
Slot 8 (P1-C16-C10)
Seventh
Eighth
Four Slot 5 (P1-C15-C7)
Slot 6 (P1-C15-C8)
Slot 7 (P1-C15-C9)
Slot 8 (P1-C15-C10)
Ninth
Tenth
One Slot 1 (P1-C18-C1)
Slot 2 (P1-C18-C2)
Slot 3 (P1-C18-C3)
Slot 4 (P1-C18-C4)
Eleventh
Twelfth
Two Slot 1 (P1-C17-C1)
Slot 2 (P1-C17-C2)
Slot 3 (P1-C17-C3)
Slot 4 (P1-C17-C4)
Thirteenth
Fourteenth
Three Slot 1 (P1-C16-C1)
Slot 2 (P1-C16-C2)
Slot 3 (P1-C16-C3)
Slot 4 (P1-C16-C4)
Fifteenth
Sixteenth
Four Slot 1 (P1-C15-C1)
Slot 2 (P1-C15-C2)
Slot 3 (P1-C15-C3)
Slot 4 (P1-C15-C4)
50 IBM Power 720 and 740: Technical Overview and Introduction
2.3.3 Memory bandwidth
The POWER7 processor has exceptional cache, memory, and interconnect bandwidths.
Table 2-8 shows the bandwidth?? estimates for the Power 720 and Power 740 systems.
Table 2-8 Power 720 and Power 740 memory and I/O bandwidth estimates
2.4 Capacity on Demand
Capacity on Demand is not supported on the Power 720 and Power 740 systems.
2.5 Factory deconfiguration of processor cores
The Power 720 and Power 740 servers have the capability to be shipped with part of the
installed cores deconfigured at the factory. The primary use for this feature is to assist with
optimization of software licensing. A deconfigured core is unavailable for use in the system
and thus does not require software licensing.
Feature #2319 deconfigures one core in a Power 720 or Power 740 systems. It is available in
a Power 720 with either 4-core, 6-core, or 8-core configurations and in a Power 740 with 12-
or 16-core configurations.
The maximum number of this feature that can be ordered is one less than the number of
cores in the system. For example a maximum of 5 x #2319 can be ordered for a 6-core
system. Feature #2319 can only be specified at initial order and cannot be applied to an
installed machine.
Notes:
Only the 8 GB Feature #4526 (2 x 4 GB DIMM) can be installed as a single feature in DIMM pairs,
and only for the first two memory features installed. All subsequent memory features must be
installed in quads (2 x feature).
DIMMs on a given memory card can differ from DIMMs on other memory cards.
DIMMs at Slot 1, 2, 3 & 4 on the same memory card must be identical. However, they can differ
from the four DIMMs at Slot 5, 6, 7 & 8 on the same memory card.
Memory Bandwidth at processor core frequencies
3.0 GHz 3.3 GHz 3.55 GHz 3.72 GHz
L1 (data) cache 144 GB/s 158.4 GB/s 170.4 GB/s 178.56 GB/s
L2 cache 144 GB/s 158.4 GB/s 170.4 GB/s 178.56 GB/s
L3 cache 96 GB/s 105.6 GB/s 113.6 GB/s 119.04 GB/s
System memory 68.22 GB/s
per socket
68.22 GB/s
per socket
68.22 GB/s
per socket
68.22 GB/s
per socket
Note: All processor cores MUST have activations ordered for them. Even the ones being
deconfigured.
Chapter 2. Architecture and technical overview 51
2.6 Technical comparison of Power 720 and Power 740
Table 2-9 shows a comparison of the technical aspects of the two systems, the Power 720
and the Power 740.
Table 2-9 Comparison of technical characteristics between Power 720 and Power 740
2.7 System bus
This section provides additional information related to the internal buses.
System characteristics Power 720 Power 740
Processor modules 4-core 3.0 GHz POWER7
6-core 3.0 GHz POWER7
8-core 3.0 GHz POWER7
4-core 3.3 GHz POWER7
4-core 3.7 GHz POWER7
6-core 3.7 GHz POWER7
8-core 3.55 GHz POWER7
Pluggable processor modules 1 only 1 or 2
Min./Max. processor cores 4/8 4/8 (4-core modules)
6/12 (6-core modules)
16/16 (8-core modules)
L3 cache on-chip eDRAM on-chip eDRAM
Max memory slots and type 8 slots per memory riser card,
(16 slots max.), DDR3 at
1066 MHz
8 slots per memory riser card,
(32 slots max.), DDR3 at
1066 MHz
Memory chipkill Yes Yes
Memory spare No No
Memory hotplug No No
TPMD card Yes Yes
PCIe x8 slots (in chassis) 8
4 full-height/short cards
4 low-profile/short cards
(optional)
8
4 full-height/short cards
4 low-profile/short cards
(optional)
PCI-X 2.0 slots in chassis n/a n/a
PCIe and PCI-X hot plug No No
PowerVM support Yes Yes
Capacity on Demand No No
Redundant hotplug power Optional Yes
DASD bays
(hot-plug, front access, SFF)
6 or 8 6 or 8
GX++ slots 1 2
52 IBM Power 720 and 740: Technical Overview and Introduction
The Power 720 and 740 systems have internal I/O connectivity through PCIe slots, as well as
external connectivity through Infiniband adapters.
The internal I/O subsystem on the Power 720 and 740 is connected to the GX bus on a
POWER7 processor in the system. This bus runs at 1.25 GHz and provides 10 GB/s of I/O
connectivity to the PCIe slots, IVE ports, SAS internal adapters and USB ports.
Additionally, the POWER7 processor chip installed on the Power 720, and each of the
processor chips on the Power 740 provide a GX++ bus which is used to optionally connect to
a 12x GX++ adapter. Each bus runs at 2.5 GHz and provides 20 GB/s bandwidth.
The slot associated with the first processor socket supports the Dual port 12x channel attach
(#5615) Feature for external I/O drawer accessibility. This slot also supports the PCIe Adapter
Riser Card (#5610).This adapter connects an additional multifunctional host bridge chip to the
first processor, which enables 4 additional PCIe slots.
One GX++ slot is available on the Power 720 and two GX++ slots are available on the Power
740. The GX++ Dual-port 12x Channel Attach Adapter (#5615) can be installed in either
GX++ slots. The first GX++ slot can also be used by the optional PCIe Adapter Riser Card
feature (#5610) to add four short, 8x, PICe low profile slots.
Table 2-10 provides I/O bandwidth of Power 720 and 740 processors configuration (review).
Table 2-10 I/O bandwidth
2.8 Internal I/O subsystem
The internal I/O subsystem resides on the system planar which support PCIe slot. PCIe slots
on the Power 720 and 740 are not hot pluggable. PCIe and PCI-X slots on the I/O drawers are
hot-pluggable.
All PCIe slots support Enhanced Error Handling (EEH). PCI EEH-enabled adapters respond
to a special data packet generated from the affected PCIe slot hardware by calling system
firmware, which will examine the affected bus, allow the device driver to reset it, and continue
without a system reboot. For Linux, EEH support extends to the majority of frequently used
devices, although various third-party PCI devices might not provide native EEH support.
An optional PCIe Adapter Riser Card (#5610) adds four short, 8x, PICe Low Profile slots and
is installed in a GX++ slot 1. All PCIe slots are EEH but not hot pluggable.
2.8.1 Slot configuration
Table 2-11 on page 53 describes the slot configuration of the Power 720 and Power 740.
Note: Neither GX++ slots support hot plug.
I/O Bandwidth
GX++ Bus 20 GB/sec (one on the Power 720, two on the Power 740)
GX+ Bus 10 GB/sec (Internal I/O)
Total I/O 30 GB/sec for Power 720
50 GB/sec for Power 740
Chapter 2. Architecture and technical overview 53
Table 2-11 Slot configuration of a Power 720 and Power 740.
2.8.2 System ports
The system planar has two serial ports that are called system ports. When an HMC is
connected to the system, the integrated system ports are rendered nonfunctional. In this
case, you must install an asynchronous adapter, which is described in Table 2-22 on page 62
for serial port usage:
Integrated system ports are not supported under AIX or Linux when the HMC ports are
connected to an HMC. Either the HMC ports or the integrated system ports can be used,
but not both.
The integrated system ports are supported for modem and asynchronous terminal
connections. Any other application using serial ports requires a serial port adapter to be
installed in a PCI slot. The integrated system ports do not support IBM PowerHA™
configurations.
Configuration of the two integrated system ports, including basic port settings (baud rate,
and so on), modem selection, call-home and call-in policy, can be performed with the
Advanced Systems Management Interface (ASMI).
2.9 Integrated Virtual Ethernet adapter
The POWER7 processor-based servers extend the virtualization technologies introduced in
POWER5 by offering the Integrated Virtual Ethernet adapter (IVE). IVE, also sometimes
named Host Ethernet Adapter (HEA), enables an easy way to manage the sharing of the
integrated high-speed Ethernet adapter ports.
Slot# Description Location code PCI Host Bridge
(PHB)
Max. card size
Slot 1 PCIe x8 P1-C4 PCIe PHB0 Full-height/short
Slot 2 PCIe x8 P1-C5 PCIe PHB1 Full-height/short
Slot 3 PCIe x8 P1-C6 PCIe PHB2 Full-height/short
Slot 4 PCIe x8 P1-C7 PCIe PHB3 Full-height/short
Slot 5a
a. Slot 5 to 8 reside on PCIe Adapter Riser Card
PCIe x8 P1-C1-C1 PCIe PHB3 Low Profile/short
Slot 6 PCIe x8 P1-C1-C2 PCIe PHB0 Low Profile/short
Slot 7 PCIe x8 P1-C1-C3 PCIe PHB2 Low Profile/short
Slot 8 PCIe x8 P1-C1-C4 PCIe PHB1 Low Profile/short
Note: Full-height PCIe adapters and low profile PCIe adapters are not interchangeable.
Even if the card was designed with low profile dimensions, the tail stock at the end of the
adapter is specific to either low profile or full height PCIe slots.
Note: The integrated console/modem port usage just described is for systems configured
as a single, system wide partition. When it is configured with multiple partitions, the
integrated console/modem ports are disabled because the TTY console and call home
functions are performed with the HMC.
54 IBM Power 720 and 740: Technical Overview and Introduction
There are various Integrated Virtual Ethernet adapter card options:
#1824 Quad-port 1 Gb HEA Daughter Card (Copper)
#1825 Dual-port 10 Gb HEA Daughter Card (Fiber)
#1826 Dual-port 10 Gb HEA Daughter Card (Copper)
The IVE includes special hardware features to provide logical Ethernet ports that can
communicate to logical partitions (LPAR) reducing the use of IBM POWER Hypervisor™
(PHYP). Its design provides a direct connection for multiple LPARs, allowing LPARs to access
external networks through the IVE without having to go through an Ethernet bridge on
another logical partition, such as a the Virtual I/O Server. Therefore, this eliminates the need
to move packets (using Virtual Ethernet Adapters) between partitions and then through a
Shared Ethernet Adapter (SEA) to an physical Ethernet port. LPARs can share IVE ports with
improved performance.
2.9.1 IVE and SEA implementations
Figure 2-9 shows the difference between IVE and SEA implementations.
Figure 2-9 Integrated Virtual Ethernet compared to Virtual I/O Server Shared Ethernet Adapter
The IVE design provides high performance Ethernet with efficient virtualization. It offers:
Either four 1 Gbps (#1832) or two 10 Gbps ports (#1833 - Fiber or #1837 - Copper)
External network connectivity for LPARs using dedicated ports without the need of a
Virtual I/O Server
Industry standard hardware acceleration, with flexible configuration possibilities
The speed and performance of the GX+ bus
Great improvement of latency for short packets that are ideal for messaging applications
such as distributed databases that require low latency communication for synchronization
and short transactions
Hypervisor
AIXHosting
Partition
AIX Linux
Virtual Ethernet Switch
Virtual
Ethernet
Driver
Virtual
Ethernet
Driver
Virtual
Ethernet
Driver
Network Adapters
Packet
Forwarder
LAN, WAN, ...
AIX AIX Linux
Using Virtual I/O Server Shared Ethernet Adapter Using Integrated Virtual Ethernet
Virtual
Ethernet
Driver
Virtual
Ethernet
Driver
Virtual
Ethernet
Driver
Integrated Virtual Ethernet
Chapter 2. Architecture and technical overview 55
Table 2-12 lists the various IVE options available on the Power 720 and 740 systems.
Table 2-12 IVE options on the Power 720 and 740
For more information about IVE features read Integrated Virtual Ethernet Adapter Technical
Overview and Introduction, REDP-4340.
2.9.2 IVE subsystem
One of the key design goals of the IVE is the capability to integrate up to two 10 Gbps
Ethernet ports or four 1 Gbps Ethernet ports into the P5IOC2 chip, with the effect of a low
cost Ethernet solution for low-end and mid-range server platforms.
Each IVE can provide 32 logical ports to client partitions on the server. The quad-port 1 Gb
adapter supports up to eight logical ports per physical port. The two dual-port 10 Gb adapters
support up to 16 logical ports per physical port. If the IVE card is replaced, then a new IVE
card provides a new set of MAC addresses.
The IVE does not have flash memory for its open firmware but it is stored in the Service
Processor flash and then passed to POWER Hypervisor control. Therefore, flash code update
is done by the POWER Hypervisor.
2.10 PCI adapters
Peripheral Component Interconnect Express (PCIe) uses a serial interface and allows for
point-to-point interconnections between devices using directly wired interface between these
connection points. A single PCIe serial link is a dual-simplex connection using two pairs of
wires, one pair for transmit and one pair for receive, and can only transmit one bit per cycle.
It can transmit at the extremely high speed of 2.5 Gbps, which equates to a burst mode of
320 MBps on a single connection. These two pairs of wires are called a lane. A PCIe link can
be composed of multiple lanes. In such configurations, the connection is labeled as x1, x2, x8,
x12, x16 or x32, where the number is effectively the number of lanes.
All adapters support Extended Error Handling (EEH); PCIe adapters use another type of slot
than PCI and PCI-X adapters. If you attempt to force an adapter into the wrong type of slot,
you might damage the adapter or the slot. A PCI adapter can be installed in a PCI-X slot, and
a PCI-X adapter can be installed in a PCI adapter slot. A PCIe adapter cannot be installed in
a PCI or PCI-X adapter slot, and a PCI or PCI-X adapter cannot be installed in a PCIe slot.
Before adding or rearranging adapters, use the System Planning Tool to validate the new
adapter configuration. See the System Planning Tool website:
http://www.ibm.com/systems/support/tools/systemplanningtool/
Feature Code Description
#1824 Quad-port 1 Gb HEA Daughter Card (Copper)
#1825 Dual-port 10 Gb HEA Daughter Card (Fiber)
#1826 Dual-port 10 Gb HEA Daughter Card (Copper)
Note: IBM i IOPs are not supported.
56 IBM Power 720 and 740: Technical Overview and Introduction
If you are installing a new feature, ensure that you have the software required to support the
new feature and determine whether there are any existing PTF prerequisites to install. To do
this, use the IBM Prerequisite website:
https://www-912.ibm.com/e_dir/eServerPreReq.nsf
The following sections discuss the supported adapters under various classifications
(LAN, SCSI, SAS, Fibre Channel (FC), and so forth) and provide tables of orderable feature
numbers. The tables indicate that the feature is supported by the AIX (A), IBM i (i), and Linux
(L) operating systems.
2.10.1 LAN adapters
To connect to a local area network (LAN), you can use Integrated Virtual Ethernet. Other LAN
adapters are supported in the system enclosure PCIe slots or in I/O enclosures that are
attached to the system using a 12X technology loop. Table 2-13 lists the additional LAN
adapters that are available.
Table 2-13 Available LAN adapters
Feature code Adapter description Slot Size OS
support
5271 PCIe LP 4-Port 10/100/1000 Base-TX
Ethernet Adapter
PCIe Low profile
Short
A, L
5272 PCIe LP 10GbE CX4 1-port Adapter PCIe Low profile
Short
A, L
5274 PCIe LP 2-Port 1GbE SX Adapter PCIe Low profile
Short
A, i, L
5275 PCIe LP 10GbE SR 1-port Adapter PCIe Low profile
Short
A, L
5706 IBM 2-Port 10/100/1000 Base-TX Ethernet
PCI-X Adapter
PCI-X Full-height
Short
A, i, L
5717 4-Port 10/100/1000 Base-TX PCI Express
Adapter
PCIe Full-height
Short
A, L
5732 10 Gigabit Ethernet-CX4 PCI Express
Adapter
PCIe Full-height
Short
A, L
5740 4-Port 10/100/1000 Base-TX PCI-X Adapter PCI-X Full-height
Short
A, L
5767 2-Port 10/100/1000 Base-TX Ethernet PCI
Express Adapter
PCIe Full-height
Short
A, i, L
5768 2-Port Gigabit Ethernet-SX PCI Express
Adapter
PCIe Full-height
Short
A, i, L
5769 10 Gigabit Ethernet-SR PCI Express Adapter PCIe Full-height
Short
A, i, L
5772 10 Gigabit Ethernet-LR PCI Express Adapter PCIe Full-height
Short
A, L
Chapter 2. Architecture and technical overview 57
2.10.2 Graphics accelerators
Table 2-14 lists the available graphics accelerators. They can be configured to operate in
either 8-bit or 24-bit color modes. These adapters support both analog and digital monitors,
and are not hot pluggable.
Table 2-14 Available graphics accelerators
2.10.3 SCSI and SAS adapters
To connect to external SCSI or SAS devices, the adapters listed in Table 2-15 are available.
Table 2-15 Available SCSI and SAS adapters
Table 2-16 shows a comparison between parallel SCSI and SAS.
Table 2-16 Comparison parallel SCSI to SAS
Feature code Adapter description Slot Size OS
support
5269 PCIe LP POWER GXT145 Graphics
Accelerator
PCIe Low profile
Short
A, L
5748 POWER GXT145 PCI Express Graphics
Accelerator
PCIe Full-height
Short
A, L
Feature code Adapter description Slot Size OS
support
5278 PCIe LP 2-x4-port SAS Adapter 3Gb PCIe Low profile
Short
A, i, L
5736 PCI-X DDR Dual Channel Ultra320 SCSI
Adapter
PCI-X Full-height
Short
A, i, L
5805 PCIe 380MB Cache Dual - x4 3Gb SAS RAID
Adapter
PCIe Full-height
Short
A, i, L
5900a
a. Supported, but is no longer orderable.
PCI-X DDR Dual -x4 SAS Adapter PCI-X Full-height
Short
A, L
5901 PCIe Dual-x4 SAS Adapter PCIe Full-height
Short
A, i, L
5908 PCI-X DDR 1.5GB Cache SAS RAID Adapter
(BSC)
PCI-X Full-height
Short
A, i, L
5912 PCI-X DDR Dual - x4 SAS Adapter PCI-X Full-height
Short
A, i, L
Feature Parallel SCSI SAS
Architecture Parallel, all devices connected
to shared bus
Serial, point-to-point, discrete
signal paths
Performance 320 MB/s (Ultra320 SCSI),
performance degrades as
devices added to shared bus
3 Gb/s, roadmap to 12 Gb/s,
performance maintained as
more devices added
Scalability 15 drives Over 16,000 drives
58 IBM Power 720 and 740: Technical Overview and Introduction
2.10.4 PCIe RAID & SSD SAS Adapter
A new SSD option for selected POWER7 processor-based servers offers a significant
price/performance improvement for many client SSD configurations. The new SSD option is
packaged somewhat differently from the currently available Power Systems SSD. The new
PCIe RAID & SSD SAS Adapter has up to four 177 GB SSD modules plugged directly onto
the adapter, thus saving the need for the SAS bays and cabling associated with the current
SSD offering. Depending on the configurations being compared to the current 69 GB
SAS-bay-based SSD offering, the new PCIe-based SSD offering can save up to 70% of the
list price, assuming equivalent GB, and up to 65% smaller footprint, assuming equivalent GB.
Figure 2-10 shows the double-wide adapter and SSD modules.
Figure 2-10 The PCIe RAID & SSD SAS Adapter and 177 GB SSD modules
Table 2-17 Available PCIe RAID & SSD SAS adapters
Compatibility Incompatible with all other drive
interfaces
Compatible with Serial ATA
(SATA)
Max. Cable Length 12 meters total (must sum
lengths of all cables used on
bus)
8 meters per discrete
connection, total domain
cabling hundreds of meters
Cable From Factor Multitude of conductors adds
bulk, cost
Compact connectors and
cabling save space, cost
Hot Pluggability Yes Yes
Device Identification Manually set, user must ensure
no ID number conflicts on bus
Worldwide unique ID set at time
of manufacture
Termination Manually set, user must ensure
proper installation and
functionality of terminators
Discrete signal paths enable
device to include termination by
default
Feature Parallel SCSI SAS
Feature
code
Adapter description Slot Size OS
support
2053a
PCIe LP RAID & SSD SAS Adapter
3 Gb
PCIe Low profile
Double wide, short
A, i, L
2054 PCIe RAID & SSD SAS 3 Gb PCIe Double wide, short A, i, L
Chapter 2. Architecture and technical overview 59
a.Only supported in the Rack-mount configuration. VIOS attachment requires, Version 2.2 or later
b.Only supported in a #5802/5877 PCIe I/O drawer. Not supported in the Power 720 740 CEC
(Central electronic Complex). VIOS attachment requires, Version 2.2 or later
The 177 GB SSD Module with Enterprise Multi-level Cell (eMLC) uses a new enterprise-class
MLC flash technology, which provides enhanced durability, capacity and performance. One,
two, or four modules can be plugged onto a PCIe RAID & SSD SAS adapter providing up to
708 GB of SSD capacity on one PCIe adapter.
Because the SSD modules are mounted on the adapter, in order to service either the adapter
or one of the modules, the entire adapter must be removed. from the system. Although the
adapter can be hot plugged when installed in a #5802 or #5877 I/O drawer, removing the
adapter also removes all SSD modules. So, to be able to hot plug the adapter and maintain
data availability, two adapters must be installed and the data mirrored across the adapters.
Under AIX and Linux, the 177 GB modules can be reformatted as JBOD disks, providing
200 GB of available disk space. This removes RAID error correcting information, so it is best
to mirror the data using operating system tools in order to prevent data loss in case of failure.
2.10.5 iSCSI
iSCSI adapters in Power Systems provide the advantage of increased bandwidth through the
hardware support of the iSCSI protocol. The 1 Gigabit iSCSI TOE (TCP/IP Offload Engine)
PCI-X adapters support hardware encapsulation of SCSI commands and data into TCP, and
transports them over the Ethernet using IP packets. The adapter operates as an iSCSI TOE.
This offload function eliminates host protocol processing and reduces CPU interrupts. The
adapter uses a small form factor LC type fiber optic connector or a copper RJ45 connector.
Table 2-18 lists the orderable iSCSI adapters.
Table 2-18 Available iSCSI adapters
2.10.6 Fibre Channel adapters
The systems support direct or SAN connection to devices using Fibre Channel adapters.
Table 2-19 provides a summary of the available Fibre Channel adapters.
All of these adapters except #5735 have LC connectors. If you are attaching a device or
switch with an SC type fibre connector, an LC-SC 50 Micron Fiber Converter Cable (#2456) or
an LC-SC 62.5 Micron Fiber Converter Cable (#2459) is required.
2055b
PCIe RAID & SSD SAS Adapter 3 Gb
w/ Blind Swap Cassette
PCIe Full-Height inside a Blind
Swap Cassette (BSC)
Double wide, short
A, i, L
Note: For tower configurations, it is possible to place a PCIe-based SSD (#2055) in a
#5802/5877 PCIe I/O drawer.
Feature
code
Adapter description Slot Size OS
support
Feature
code
Adapter description Slot Size OS
support
#5713 1 Gigabit iSCSI TOE PCI-X on Copper Media
Adapter
PCI-X Full-height
Short
A, i, L
60 IBM Power 720 and 740: Technical Overview and Introduction
Table 2-19 Available Fibre Channel adapters
2.10.7 Fibre Channel over Ethernet
Fibre Channel over Ethernet (FCoE) allows for the convergence of Fibre Channel and
Ethernet traffic onto a single adapter and converged fabric.
Figure 2-11 shows a comparison between existing FC and network connections and FCoE
connections.
Figure 2-11 Comparison between existing FC and network connection and FCoE connection
Table 2-20 lists the available Fibre Channel over Ethernet Adapters. They are high
performance, Converged Network Adapters (CNA) using SR optics. Each port can provide
Network Interface Card (NIC) traffic and Fibre Channel functions simultaneously.
Feature
code
Adapter description Slot Size OS
support
#5273 PCIe LP 8Gb 2-Port Fibre Channel Adapter PCIe Low profile
Short
A, i, L
#5276 PCIe LP 4Gb 2-Port Fibre Channel Adapter PCIe Low profile
Short
A, i, L
#5735 8 Gigabit PCI Express Dual Port Fibre Channel
Adapter
PCIe Full-height
Short
A, i, L
#5749 4 Gbps Fibre Channel (2-Port) PCI-X Full-height
Short
i
#5759 4 Gb Dual-Port Fibre Channel PCI-X 2.0 DDR
Adapter
PCI-X Full-height
Short
A, L
#5774 4 Gigabit PCI Express Dual Port Fibre Channel
Adapter
PCIe Full-height
Short
A, i, L
Note: NPIV is supported through the Virtual I/O server with adapters #5273 and #5735.
Ethernet
and Fibre
Channel
Cables
Ethernet
Cable
Fibre Channel
Cable
FC Switch
Ethernet Switch
CEC or I/O Drawer
Ethernet
CEC or I/O Drawer
FC
Rack
Fibre Channel (FC)
Device or FC Switch
Ethernet
Cables
Ethernet
Cable
Fibre Channel
Cable
FCoE Switch
CEC or I/O Drawer
Rack
Fibre Channel (FC)
Device or FC Switch
FCoE
Ethernet Device/
Switch
Ethernet Device/
Switch or FCoE
Device/Switch
Chapter 2. Architecture and technical overview 61
Table 2-20 Available FCoE Adapters.
2.10.8 InfiniBand Host Channel adapter
The InfiniBand Architecture (IBA) is an industry-standard architecture for server I/O and
inter-server communication. It was developed by the InfiniBand Trade Association (IBTA) to
provide the levels of reliability, availability, performance, and scalability necessary for present
and future server systems with levels significantly better than can be achieved using
bus-oriented I/O structures.
InfiniBand (IB) is an open set of interconnect standards and specifications. The main IB
specification has been published by the InfiniBand Trade Association and is available at:
http://www.infinibandta.org/
InfiniBand is based on a switched fabric architecture of serial point-to-point links, where these
IB links can be connected to either host channel adapters (HCAs), used primarily in servers,
or target channel adapters (TCAs), used primarily in storage subsystems.
The InfiniBand physical connection consists of multiple byte lanes. Each individual byte lane
is a four wire, 2.5, 5.0, or 10.0 Gbps bi-directional connection. Combinations of link width and
byte lane speed allow for overall link speeds from 2.5 Gbps to 120 Gbps. The architecture
defines a layered hardware protocol as well as a software layer to manage initialization and
the communication between devices. Each link can support multiple transport services for
reliability and multiple prioritized virtual communication channels.
For more information about Infiniband, read HPC Clusters Using InfiniBand on IBM Power
Systems Servers, SG24-7767.
IBM offers the GX++ 12X DDR Adapter (#5615) that plugs into the system backplane (GX++
slot). One GX++ slot is available on the Power 720. Two GX++ slots are available on the
Power 740. This adapter allows the attachment of up to four I/O Drawers in a single loop
designed for the 12X Channel. By attaching a 12X to 4X converter cable (#1828, #1841or
#1842) an IB switch can be attached. AIX, IBM i, and Linux operating systems are supported.
A new PCIe2 LP 2-Port 4X Infiniband quad data rates (QDR ) Adapter 40 Gb (#5283) is
available. The PCIe Gen2 low-profile adapter provides two high-speed 4X InfiniBand
connections for IP over Infiniband (IB) usage in the Power 720 and Power 740. On the
Power 720 and Power 740, this adapter is supported in PCIe Gen2 slots, which are provided
in the PCIe Gen2 Riser Card (#5685). At time of writing , there are no other PCIe Gen2 slots
available on the Power 710, 720, 730, 740, 750, 755, 770, 780, or 795. Where Gen2 PCIe
slots are not available, continue to use the 12X DDR adapter in a GX slot plus a 12X to 4X
cable for four InfiniBand connections (#1828, #1841 or #1842).
Five QDR IB cables are provided for attachment to the QDR adapter and its QSFP(Quad
Small Form-Factor Pluggable) connectors.
Copper cables provide 1-, 3-, and 5-meter lengths (#3287, #3288, and 3289)
Feature code Adapter description Slot Size OS
support
5270 PCIe LP 10Gb FCoE 2-port Adapter PCIe Low profile
Short
A, L
5708 10Gb FCoE PCIe Dual Port Adapter PCIe Full-height
Short
A, L
62 IBM Power 720 and 740: Technical Overview and Introduction
optical cables provide 10- and 30-meter lengths (#3290, #3293). These are QSFP/QSFP
cables that then also attach to QSFP ports on the switch.
The feature 5283 QDR adapter attaches to the QLogic QDR switches. These switches can
ordered from IBM using the following machine types and models:
7874-036, is a QLogic 12200 36-port, 40 Gbps InfiniBand Switch that cost-effectively links
workgroup resources into a cluster.
7874-072, is a QLogic 12800-040 72-port, 40 Gbps InfiniBand switch which links
resources using a scalable, low-latency fabric, supporting up to four 18-port QDR Leaf
Modules.
7874-324; it is a QLogic 12800-180 324-port 40 Gbps InfiniBand switch designed to
maintain larger clusters, supporting up to eighteen 18-port QDR Leaf Modules.
Drivers to allow direct attachment to another feature 5283 QDR Adapter are not provided by
IBM.
Note that the feature 5283 adapter has two 40 Gb ports and a PCIe Gen2 slot has the
bandwidth to support one port. So the benefit of two ports will be for additional attachment
redundancy, not for additional performance.
Table 2-21 lists the available Infiniband adapters.
Table 2-21 Available Infiniband adapters
2.10.9 Asynchronous adapter
Asynchronous PCI adapters provide connection of asynchronous EIA-232 or RS-422
devices. If you have a cluster configuration or high-availability configuration and plan to
connect the IBM Power Systems using a serial connection, you can use the features listed in
Table 2-22.
Table 2-22 Available asynchronous adapters
2.11 Internal storage
The Power 720 and Power 740 servers use an integrated SAS/SATA connected to a 66 MHz
PCI-X bus on the P5-IOC2 chip (see Figure 2-12 on page 63). The SAS/SATA controller used
in the server’s enclosure has two sets of 4 SAS/SATA channels. Each channel can support
Feature code Adapter description Slot Size OS
support
5283 PCIe2 LP 2-Port 4X IB QDR Adapter 40Gb PCIe Low profile
Short
A, L
5615 GX++ Dual-port 12x Channel Attach GX++ - A, i, L
Feature code Adapter description Slot Size OS
support
5277 PCIe LP 4-Port Async EIA-232 Adapter PCIe Low profile
Short
A, L
5785 4 Port Async EIA-232 PCIe Adapter PCIe Full-height
Short
A, L
Chapter 2. Architecture and technical overview 63
either SAS or SATA operation. The SAS controller is connected to a DASD backplane and
supports, depending on the following two backplane options:
The first (#5618) provides a storage backplane which supports six SFF (Small Form
Factor) HDDs or SSDs and connections for a slimline SATA DVD and a half high tape for
either a tape drive or USB removable disk drive. SFF drives are supported using JBOD or
RAID-0. Split backplane (3x3) and RAID-10 support requires additional feature (#5631),
but no PCIe SAS adapter is required.
The second (#5630) is a higher-function backplane that supports up to eight SFF SAS
HDDs/SSDs, a SATA DVD, a half-high tape drive for either a tape drive or USB removable
disk, Dual 175 MB Write Cache RAID, and one external SAS port. The #5630 supports
RAID 5 and RAID 6 and there is no split backplane available for this feature.
Figure 2-12 details the internal topology overview for the #5618 backplane.
Figure 2-12 Internal topology overview for #5618 DASD Backplane
Note: The feature #5618 is not supported with IBM i.
Note: This feature (#5630) is required by IBM i to natively use the internal storage
(HDDs/SSDs and media) and the system SAS port.
Hard
disk
2
Hard
disk
3
Hard
disk
1
Hard
disk
4
Hard
disk
5
Hard
disk
6
SAS Controller
DASD and media backplane
DVD
PCI-X 64b
66MHz
P5-IOC2
GX+
Pass thru
PCIX PHB2 PCIX PHB0 PCIX PHB3
IVE
IVE
PCIe x8 PHB0
PCIe x8 PHB1
PCIe x8 PHB2
PCIe x8 PHB3
SAS Controller
Tape
Drive
64 IBM Power 720 and 740: Technical Overview and Introduction
Figure 2-13 shows the internal topology overview for the #5630 backplane:
Figure 2-13 #5630 DASD Backplane - Internal topology overview
2.11.1 RAID support
There are multiple protection options for HDD/SSD drives in the SAS SFF bays in the
Power 720 and 740 system unit or drives in 12X attached I/O drawers or drives in disk-only
I/O drawers. Although protecting drives is always the best idea, AIX/Linux users can choose
to leave a few or all drives unprotected at their own risk, and IBM supports these
configurations. IBM i configuration rules differ in this regard, and IBM supports IBM i partition
configurations only when HDD/SSD drives are protected.
Drive protection
HDD/SSD drive protection can be provided by AIX, IBM i, and Linux software or by the
HDD/SSD hardware controllers. Mirroring of drives is provided by AIX, IBM i, and Linux
software. In addition, AIX/Linux supports controllers providing RAID 0, 1, 5, 6, or 10. IBM i
integrated storage management already provides striping so IBM i also supports controllers
providing RAID 5 or 6. To further augment HDD/SSD protection, hot spare capability can be
used for protected drives. Specific hot spare prerequisites apply.
An integrated SAS HDD/SSD controller is provided in the Power 720 and Power 740 system
units. It is optionally augmented by RAID 5 and RAID 6 capability when #5630 is added to the
configuration. Without #5630, the integrated controller supports system mirroring protection
for AIX, IBM i, and Linux and supports RAID 0 or 10 protection for AIX and Linux. Other disk
and SSD controllers are available as PCI adapters, as well as PCI-X SCSI, PCI-X SAS, and
PCIe SAS adapters.
Hard
disk
4
Hard
disk
5
Hard
disk
3
Hard
disk
6
Hard
disk
7
Hard
disk
8
SAS Controller
DASD and media backplane
DVD
PCI-X 64b
66MHz
P5-IOC2
GX+
Pass thru
PCIX PHB2 PCIX PHB0 PCIX PHB3
IVE
IVE
PCIe x8 PHB0
PCIe x8 PHB1
PCIe x8 PHB2
PCIe x8 PHB3
RAID Option
External SAS
Port
Hard
disk
2
Hard
disk
1
Tape
Drive
Chapter 2. Architecture and technical overview 65
PCI Controllers with and without write cache are supported. RAID 5 and RAID 6 on
controllers with write cache are supported with one exception. The PCIe RAID & SSD SAS
adapter has no write cache but supports RAID 5 and RAID 6.
AIX and Linux can use disk drives formatted with 512-byte blocks when being mirrored by the
operating system. These disk drives must be reformatted to 528-byte sectors when used in
RAID arrays. Although a small percent-age of the drive's capacity is lost, additional data
protection such as ECC and bad block detection is gained in this reformatting. For example, a
300 GB disk drive, when reformatted, provides around 283 GB. IBM i always uses drives
formatted to 528 bytes. IBM Power SSDs are formatted to 528 bytes.
Power 720 and 740 support a dual write cache RAID feature which consists of an auxiliary
write cache for RAID card and the optional RAID enablement.
Supported RAID functions
The RAID enablement feature and the auxiliary write cache are optional features. When
features are configured, Power 720 and 740 support hardware RAID 0, 1, 5, 6 and 10:
RAID-0 provides striping for performance, but does not offer any fault tolerance.
The failure of a single drive will result in the loss of all data on the array. This increases I/O
bandwidth by simultaneously accessing multiple data paths.
RAID-5 uses block-level data striping with distributed parity.
RAID-5 stripes both data and parity information across three or more drives. Fault
tolerance is maintained by ensuring that the parity information for any given block of data
is placed on a drive separate from those used to store the data itself.
RAID-6 uses block-level data striping with dual distributed parity.
RAID-6 is the same as RAID-5 except that it uses a second level of independently
calculated and distributed parity information for additional fault tolerance. RAID-6
configuration requires N+2 drives to accommodate the additional parity data, which makes
it less cost effective than RAID-5 for equivalent storage capacity.
RAID-10 is also known as stripe set of mirrored arrays.
It is a combination of RAID-0 and RAID-1. A RAID-0 stripe set of the data is created
across a 2-disk array for performance benefits. A duplicate of the first stripe set is then
mirrored on another 2-disk array for fault tolerance.
2.11.2 External SAS port and split backplane
This section describes the external SAS port and split backplane features.
External SAS port feature
The Power 720 and 740 DASD backplane (#5630) offers an external SAS port:
The SAS port connector is located next to the GX++ slot 2 on the rear bulkhead.
The external SAS port can be used to connect external SAS devices (#5886 or #5887),
System Storage 7214 Tape and DVD Enclosure 7214-IU2 or the Multi-media Enclosure
7316-1U2.
Note: Only one SAS drawer is supported from the external SAS port. Additional SAS
drawers can be supported by SAS adapters. SSDs are not supported on the SAS drawer
connected to the external port.
66 IBM Power 720 and 740: Technical Overview and Introduction
Split DASD backplane feature
Power 720 and 740 DASD backplane (#5618) supports split drive bay (#5631). If #5631 is
configured, then the six Small Form Factors (SFFs) are split into a pair of three drive bay
groups (3x3) and RAID-10 capability is enabled. Figure 2-14 details the split backplane.
Figure 2-14 Internal topology overview for #5618 DASD Backplane with Split backplane feature #5631
2.11.3 Media bays
The Power 720 and 740 each offer a slim media bay to support a slim SATA DVD device.
Direct dock and hot-plug of the DVD media device are supported. Also, the half-high bay is
available to support an optional SAS tape drive or removable disk drive.
Note: In a Power 720 and 740 with a split backplane, SSDs and HDDs can be placed in
either “split” but no mixing of SSDs and HDDs within a split is allowed. IBM i does not
support split backplane.
Hard
disk
2
Hard
disk
3
Hard
disk
1
Hard
disk
4
Hard
disk
5
Hard
disk
6
SAS Controller
DASD and media backplane
DVD
PCI-X 64b
66MHz
P5-IOC2
GX+
Pass thru
PCIX PHB2 PCIX PHB0 PCIX PHB3
IVE
IVE
PCIe x8 PHB0
PCIe x8 PHB1
PCIe x8 PHB2
PCIe x8 PHB3
SAS Controller
Tape
Drive
Chapter 2. Architecture and technical overview 67
2.12 External I/O subsystems
This section describes the external 12X I/O subsystems that can be attached to the
Power 720 and Power 740, listed as follows:
PCI-DDR 12X Expansion Drawer (#5796)
12X I/O Drawer PCIe, SFF disk (#5802)
12X I/O Drawer PCIe, No Disk (#5877)
12X I/O Drawer PCIe with SFF Disks (#5802)
Table 2-23 provides an overview of the capabilities of the supported I/O drawers:
Table 2-23 I/O drawer capabilities
Each processor card feeds one GX++ Adapter slot. On the Power 720, there can be one
GX++ slot available, and on the Power 740, there can be one or two, depending on whether
one or two processor modules are installed.
2.12.1 PCI-DDR 12X Expansion Drawer
The PCI-DDR 12X Expansion Drawer (#5796) is a 4U (EIA units) drawer and mounts in a
19-inch rack. Feature #5796 is 224 mm (8.8 in.) wide and takes up half the width of the 4U
(EIA units) rack space. The 4U enclosure can hold up to two #5796 drawers mounted
side-by-side in the enclosure. The drawer is 800 mm (31.5 in.) deep and can weigh up to
20 kg (44 lb).
The PCI-DDR 12X Expansion Drawer has six 64-bit, 3.3 V, PCI-X DDR slots, running at
266 MHz and that use blind-swap cassettes and support hot-plugging of adapter cards. The
drawer includes redundant hot-plug power and cooling.
Two interface adapters are available for use in the #5796 drawer: Dual-Port 12X Channel
Attach Adapter Long Run (#6457) or Dual-Port 12X Channel Attach Adapter Short Run
(#6446). The adapter selection is based on how close the host system or the next I/O drawer
in the loop is physically located. Feature #5796 attaches to a host system CEC enclosure with
a 12X adapter in a GX++ slot through SDR or DDR cables (or both SDR and DDR cables).
A maximum of four #5796 drawers can be placed on the same 12X loop. Mixing #5802/5877
and #5796 on the same loop is not supported.
A minimum configuration of two 12X cables (either SDR or DDR), two ac power cables, and
two SPCN cables, is required to ensure proper redundancy.
Feature code DASD PCI slots Requirements for a 720/740
#5796 None 6 x PCI-X GX++ adapter card #5615 and
interface attach 6446/6457
#5802 18 x SFF disk drive bays 10 x PCIe GX++ adapter card #5615
#5877 None 10 x PCIe GX++ adapter card #5615
#5887 24 x SAS disk drive bays None SAS PCI-X or PCIe adapter
#5886 12 x SAS disk drive bays None SAS PCI-X or PCIe adapter
Note: The attachment of external I/O drawers is not supported on the 4-core Power 720.
68 IBM Power 720 and 740: Technical Overview and Introduction
Figure 2-15 shows the back view of the expansion unit.
Figure 2-15 PCI-X DDR 12X Expansion Drawer rear side
2.12.2 12X I/O Drawer PCIe
The 12X I/O Drawer PCIe (#5802) is a 19-inch I/O and storage drawer. It provides a 4U-tall
(EIA units) drawer containing ten PCIe based I/O adapter slots and eighteen SAS hot-swap
Small Form Factor disk bays, which can be used for either disk drives or SSD. The adapter
slots use blind-swap cassettes and support hot-plugging of adapter cards.
A maximum of two #5802 drawers can be placed on the same 12X loop. Feature #5877 is the
same as #5802 except it does not support any disk bays. Feature #5877 can be on the same
loop as #5802. Feature #5877 cannot be upgraded to #5802.
The physical dimensions of the drawer measure 444.5 mm (17.5 in.) wide by 177.8 mm
(7.0 in.) high by 711.2 mm (28.0 in.) deep for use in a 19-inch rack.
A minimum configuration of two 12X DDR cables, two ac power cables, and two SPCN cables
is required to ensure proper redundancy. The drawer attaches to the host CEC enclosure with
a 12X adapter in a GX++ slot through 12X DDR cables that are available in various cable
lengths: 0.6 (#1861), 1.5 (#1862), 3.0 (#1865), or 8 meters (#1864). The 12X SDR cables are
not supported.
P1-C8-T3 P1-C1
P1-C2
P1-C3 P1-C4
P1-C5
E1
P1-C6
E2
12X Port 1
(P1-C7-T2)
SPCN 0
(P1-C8-T1)
SPCN 1
(P1-C8-T2)
12X Port 0
(P1-C7-T1)
C
1
C
2
C
3
C
4
C
5
C
6
Chapter 2. Architecture and technical overview 69
Figure 2-16 shows the front view of the 12X I/O Drawer PCIe (#5802).
Figure 2-16 Front view of the 12X I/O Drawer PCIe
Figure 2-17 shows the rear view of the 12X I/O Drawer PCIe (#5802).
Figure 2-17 Rear view of the 12X I/O Drawer PCIe
2.12.3 Dividing SFF drive bays in a 12X I/O drawer PCIe
Disk drive bays in a 12X I/O drawer PCIe can be configured as a set of one, two, or four,
allowing for partitioning of disk bays. Disk bay partitioning configuration can be done by
physical mode switch on the I/O drawer.
Disk drives Service card Port cards
Power cables
10 PCI-e cards X2 SAS connectors
12X connectors Mode switch
SPCN connectors
Note: Mode change using the physical mode switch requires power-off/on of the drawer.
70 IBM Power 720 and 740: Technical Overview and Introduction
Figure 2-17 on page 69 indicates the Mode Switch in the rear view of the #5802 I/O Drawer.
Each disk bay set can be attached to its own controller or adapter. #5802 PCIe 12X I/O
Drawer has four SAS connections to drive bays. It connects to PCIe SAS adapters or
controllers on the host system.
Figure 2-18 shows the configuration rule of disk bay partitioning in the #5802 PCIe 12X I/O
Drawer. There is no specific feature code for mode switch setting.
Figure 2-18 Disk Bay Partitioning in #5802 PCIe 12X I/O drawer
The SAS ports, as associated with the mode selector switch map to the disk bays, have the
mappings shown in Table 2-24.
Table 2-24 SAS connection mappings
Note: The IBM System Planing Tool supports disk bay partitioning. Also, the IBM
configuration tool accepts this configuration from IBM System Planing Tool and passes it
through IBM manufacturing using the Customer Specified Placement (CSP) option.
Location code Mappings Number of bays
P4-T1 P3-D1 to P3-D5 5 bays
P4-T2 P3-D6 to P3-D9 4 bays
P4-T3 P3-D10 to P3-D14 5 bays
P4-T3 P3-D15 to P3-D18 4 bays
Chapter 2. Architecture and technical overview 71
Location codes for #5802 I/O drawer
The location codes for the front and rear views of the #5802 I/O drawer are provided in
Figure 2-19 and Figure 2-20.
Figure 2-19 5802 I/O drawer from view location codes
Figure 2-20 5802 I/O drawer rear view location codes
72 IBM Power 720 and 740: Technical Overview and Introduction
Configuring the #5802 disk drive subsystem
The #5802 SAS disk drive enclosure can hold up 18 disk drives. The disks in this enclosure
can be organized in various configurations depending on the operating system used, the type
of SAS adapter card, and the position of the mode switch.
Each disk bay set can be attached to its own controller or adapter. Feature #5802 PCIe 12X
I/O Drawer has four SAS connections to drive bays. It connects to PCIe SAS adapters or
controllers on the host systems.
For detailed information about how to configure, see the IBM Power Systems Hardware
Information Center at:
http://publib.boulder.ibm.com/infocenter/powersys/v3r1m5/index.jsp
2.12.4 12X I/O drawer PCIe and PCI-DDR 12X Expansion Drawer 12X cabling
I/O Drawers are connected to the adapters in the CEC enclosure with data transfer cables:
12X DDR cables for the #5802 and #5877 I/O drawers, and 12X SDR and/or DDR cables for
the #5796 I/O drawers. The first 12X I/O Drawer that is attached in any I/O drawer loop
requires two data transfer cables. Each additional drawer, up to the maximum allowed in the
loop, requires one additional data transfer cable. Note the following information:
A 12X I/O loop starts at a CEC bus adapter port 0 and attaches to port 0 of an I/O drawer.
The I/O drawer attaches from port 1 of the current unit to port 0 of the next I/O drawer.
Port 1 of the last I/O drawer on the 12X I/O loop connects to port 1 of the same CEC bus
adapter to complete the loop.
Figure 2-21 shows typical 12X I/O loop port connections.
Figure 2-21 Typical 12X I/O loop port connections
I/O I/O
1 0
I/O
1 0
I/O
10
I/O
10
C
0
1
Chapter 2. Architecture and technical overview 73
Table 2-25 shows various 12X cables to satisfy the various length requirements.
Table 2-25 12X connection cables
General rules for 12X IO Drawer configuration
If you have two processor cards, spread the I/O drawers across two busses for better
performance. Figure 2-22 lists the configuration to attach 12X IO Drawers to a Power 720.
Figure 2-22 12X IO Drawer configuration for a Power 720 with one GX++ slot
Feature code Description
1861 0.6 Meter 12X DDR Cable
1862 1.5 Meter 12X DDR Cable
1865 3.0 Meter 12X DDR Cable
1864 8.0 Meter 12X DDR Cable
PCIe
720
+
+
One I/O-Drawer
PCIe
720
+
+
Two I/O-Drawers
PCIe
PCI-X
720
+
+
One I/O-Drawer
PCI-X
720
+
+
Four I/O-Drawers
PCI-X
PCI-X
PCI-X
74 IBM Power 720 and 740: Technical Overview and Introduction
The configuration rules are the same for the Power 740. However, because the Power 740
can have up to two GX++ slots, you have various options available to attach 12X IO drawers.
Figure 2-23 shows four of them, but there are more options available.
Figure 2-23 12X IO Drawer configuration for a Power 740 with one GX++ slot
Supported 12X cable length for PCI-DDR 12X Expansion Drawer
Each #5796 drawer requires one Dual Port PCI DDR 12X Channel Adapter, either Short Run
(#6446) or Long Run (#6457). The choice of adapters is dependent on the distance to the
next 12X Channel connection in the loop, either to another I/O drawer or the system unit.
Table 2-26 identifies the supported cable lengths for each 12X channel adapter. I/O drawers
containing the Short Range adapter can be mixed in a single loop with I/O drawers containing
the Long Range adapter. In Table 2-26, a “Yes” indicates that the 12X cable identified in that
column can be used to connect the drawer configuration identified to the left. A “No” means it
cannot be used.
Table 2-26 Supported 12X cable length
Connection type 12X cable options
0.6 M 1.5 M 3.0 M 8.0 M
#5796 to #5796 with #6446 in both drawers Yes Yes No No
#5796 with #6446 adapter to #5796 with 6457 adapter Yes Yes Yes No
#5796 to #5796 with 6#457 adapter in both drawers Yes Yes Yes Yes
#5796 with #6446 adapter to system unit No Yes Yes No
#5796 with #6457 adapter to system unit No Yes Yes No
PCIe
740
+
+
Three I/O-Drawers
PCIe
Six I/O-Drawers
PCI-X
PCI-X
PCI-X
PCI-X
PCIe
PCIe
740
+
+
+
+
PCI-X+
+
PCIe
740
+
+
Four I/O-Drawers
PCIe
PCI-X
PCI-X
+
+
Two I/O-Drawers
PCIe740
+
+ PCIe
+
+
Chapter 2. Architecture and technical overview 75
2.12.5 12X I/O Drawer PCIe and PCI-DDR 12X Expansion Drawer SPCN cabling
The System Power Control Network (SPCN) is used to control and monitor the status of
power and cooling within the I/O drawer.
SPCN cables connect all ac powered expansion units as shown in the following example
diagram, Figure 2-24.
1. Start at SPCN 0 (T1) of the CEC unit to J15 (T1) of the first expansion unit.
2. Cable all units from J16 (T2)of the previous unit to J15 (T1) of the next unit.
3. To complete the cabling loop, from J16 (T2) of the final expansion unit, connect to the
CEC, SPCN 1 (T2).
4. Ensure that a complete loop exists from the CEC, through all attached expansions and
back to the CEC drawer.
Figure 2-24 SPCN cabling examples
Table 2-27 shows SPCN cables to satisfy various length requirements:
Table 2-27 SPCN cables
2.13 External disk subsystems
This section describes The following external disk subsystems that can be attached to the
Power 720 and Power 740, listed as follows:
EXP 12S SAS Expansion Drawer (#5886 - Supported, but is no longer orderable).
EXP 24S SFF Gen2-bay Drawer for high-density storage(#5887)
TotalStorage EXP24 Disk Drawer (#5786) and Tower (#5787)
J15
J16 J15
J16
J15
J16
System Unit
1
0
Feature code Description
6006 SPCN cable drawer-to-drawer, 2 m
6008a
a. Supported, but no longer orderable
SPCN cable rack-to-rack, 6 m
6007 SPCN cable rack-to-rack, 15 m
6029a
SPCN cable rack-to-rack, 30 m
76 IBM Power 720 and 740: Technical Overview and Introduction
IBM 7031 TotalStorage EXP24 Ultra320 SCSI Expandable Storage Disk Enclosure
(no longer orderable)
IBM System Storage
The next sections describe the EXP 12S Expansion Drawer, the 12X I/O Drawer PCIe with
SFF Disks drawer, and IBM System Storage in more detail.
2.13.1 EXP 12S SAS Expansion Drawer
The EXP 12S (#5886) is an expansion drawer with twelve 3.5-inch form factor SAS bays.
#5886 supports up to 12 hot-swap SAS Hard Disk Drives (HDD) or up to 8 hot-swap Solid
State Drives (SSD). The EXP 12S includes redundant ac power supplies and two power
cords. Though the drawer is one set of 12 drives which is run by one SAS controller or one
pair of SAS controllers, it has two SAS attachment ports and two Service Managers for
redundancy. The EXP 12S takes up a 2 EIA space in a 19-inch rack. The SAS controller can
be a SAS PCI-X or PCIe adapter or pair of adapters.
At the time of writing, a single disk-only EXP 12S SAS Expansion Drawer (#5886) is
supported from the external SAS port of a Power 720 and Power 740 server. Additional EXP
12S Drawers can be supported using PCI-X or PCIe SAS adapters. A maximum of 28 EXP
12S Drawers are supported on a Power 720 and Power 740 server.
The drawer can either be attached using the #5630 storage backplane, providing an external
SAS port, or using one of the following adapters:
PCIe LP 2-x4-port SAS 3GB adapter (#5278)
PCIe 380 MB Cache Dual -x4 3 GB SAS RAID adapter (#5805)
PCI-X DDR Dual -x4 SAS adapter (#5900)
PCIe Dual -x4 SAS adapter (#5901)
PCIe 380 MB Cache Dual -x4 3 GB SAS RAID adapter (#5903)
PCI-X DDR 1.5 GB Cache SAS RAID adapter (#5904)
PCI-X DDR Dual -x4 SAS adapter (#5912)
With proper cabling and configuration, multiple wide ports are used to provide redundant
paths to each dual port SAS disk. The adapter manages SAS path redundancy and path
switching in case a SAS drive failure occurs. The SAS Y cables attach to an EXP 12S Disk
Drawer. Use SAS cable (YI) system to SAS enclosure, single controller/dual path 1.5M
(#3686 - supported but not longer orderable) or SAS cable (YI) system to SAS enclosure,
single controller/dual path 3M (#3687) to attach SFF SAS drives in an EXP12S Drawer.
Figure 2-25 on page 77 illustrates connecting a system external SAS port to a disk expansion
drawer
Note: The 4-core Power 720 server does not support the attachment of an EXP12S
Drawer.
Note: If you use a PCI-X SAS adapter within the Power 720 and 740, a PCI-X DDR 12X
Expansion Drawer (#5796) or a 7314-G30 drawer is required.
Chapter 2. Architecture and technical overview 77
Figure 2-25 External SAS Cabling
Use SAS cable (YO) system to SAS enclosure, single controller/dual path 1.5M (#3450) or
SAS cable (YO) system to SAS enclosure, single controller/dual path 3M (#3451) to attach
SFF SAS drives in an EXP12S Drawer. In the EXP 12S Drawer, a high availability I/O
configuration can be created using a pair of #5278 adapters and SAS X cables to protect
against the failure of a SAS adapter.
Various disk options are available to be installed in the EXP 12S drawer. Table 2-28 on
page 77 shows the available disk drive feature codes.
Table 2-28 Disk options for the EXP 12S drawer
Feature code Description OS support
#3586 69 GB 3.5" SAS Solid State Drive AIX, Linux
#3587 69 GB 3.5” SAS Solid State Drive IBM i
#3646 73.4 GB 15K RPM SAS Disk Drive AIX. Linux
#3647 146.8 GB 15K RPM SAS Disk Drive AIX, Linux
#3648 300 GB 15K RPM SAS Disk Drive AIX, Linux
#3649 450 GB 15K RPM SAS Disk Drive AIX, Linux
#3658 428.4 GB 15K RPM SAS Disk Drive IBM i
#3676 69.7 GB 15K RPM SAS Disk Drive IBM i
#3677 139.5 GB 15K RPM SAS Disk Drive IBM i
#3678 283.7 GB 15K RPM SAS Disk Drive IBM i
78 IBM Power 720 and 740: Technical Overview and Introduction
A second EXP12S drawer can be attached to another drawer using two SAS EE cables,
providing 24 SAS bays instead of 12 bays for the same SAS controller port. This is called
cascading. In this configuration, all 24 SAS bays are controlled by a single controller or a
single pair of controllers.
The EXP12S Drawer can also be directly attached to the SAS port on the rear of the
Power 720 and Power 740, providing a very low cost disk storage solution. The rear SAS port
is provided by the Storage Backplane - 8 SFF Bays/175MB RAID/Dual IOA (#5630).
A second unit cannot be cascaded to an EXP12S Drawer attached in this way.
For detailed information about the SAS cabling, see the Serial-attached SCSI cable planning
documentation at:
http://publib.boulder.ibm.com/infocenter/powersys/v3r1m5/index.jsp?topic=/p7had/p7
hadsascabling.htm
2.13.2 EXP 24S SAS Expansion Drawer
The EXP 24S (#5887) SFF Gen2-bay Drawer is an expansion drawer with twenty-four 2.5-
inch small form factor (SFF) SAS bays. It supports up to 24 hot-swap SFF SAS Hard Disk
drives (HDD) on POWER6 or POWER7 servers in 2U of 19-inch rack space.
The SFF bays of the EXP 24S are different from the SFF bays of the POWER7 system
units or 12X PCIe I/O Drawers (#5802, #5803). The EXP 24S uses Gen-2 or SFF-2 SAS
drives that physically do not fit in the Gen-1 or SFF-1 bays of the POWER7 system unit or
12X PCIe I/O Drawers or viceversa.
The EXP 24S SAS ports are attached to SAS controllers which can be a SAS PCI-X or PCIe
adapter or pair of adapters. The EXP24S can also be attached to an imbedded SAS controller
in a server with an imbedded SAS port. Attachment between the SAS controller and the
EXP24S SAS ports is via the appropriate SAS Y or X cables.
The drawer can either be attached using the #5268 storage backplane, providing an external
SAS port, or using a LP 2-x4-port SAS adapter 3 Gb (#5278).
Note: A EXP 12S Drawer containing SSD drives cannot be attached to the CEC external
SAS port on the Power 720 and Power 740 or through a PCIe LP 2-x4 port SAS adapter
3Gb (#5278). If this configuration is required, use a high-profile PCIe SAS adapter or a
PCI-X SAS adapter.
Note: If the internal disk bay of the Power 720 or Power 740 contains any SSD drives,
an EXP 12S Drawer cannot be attached to the external SAS port on the Power 720 or
Power 740 (this applies even if the I/O drawer only contains SAS disk drives).
Note: SSD not currently supported
Note: A single #5887 drawer can be cabled to the CEC external SAS port when a #5268
DASD backplane is part of the system. A 3Gb/s YI cable (#3686/#3687) is used to connect
a #5887 to the CEC external SAS port.
A single #5887 will not be allowed to attach to the CEC external SAS port when a #8350
processor (4-core) is ordered/installed on a single socket Power 710 system.
Chapter 2. Architecture and technical overview 79
The EXP 24S can be ordered in one of 3 possible manufacturing-configured MODE settings
(not customer set-up).
1, 2 or 4 sets of disk bays
With IBM AIX/Linux/VIOS, the EXP 24S can be ordered with four sets of 6 bays (mode4), two
sets of 12 bays (mode 2) or one set of 24 bays (mode 1). With IBM i the EXP24S can be
ordered as one set of 24 bays (mode 1).
There are six SAS connectors on the rear of the EXP 24S to which SAS adapters/
controllers are attached. They are labeled T1, T2, and T3, and there are two T1, two T2,
and two T3, details on Figure 2-26.
In mode 1, two or four of the six ports are used. Two T2 are used for a single SAS adapter,
and two T2 and two T3 are used with a paired set of two adapters or dual adapters
configuration
In mode 2 or mode 4, four ports will be used, two T2 and two T3 in order to access allSAS
bays.
Figure 2-26 #5887 rear connectors
An EXP 24S in mode 4 can be attached to two or four SAS controllers and provide a great
deal of configuration flexibility. An EXP24S in mode 2 has similar flexibility. Up to 24 HDDs
can be supported with any of the supported SAS adapters/controllers.
EXP24S no-charge specify codes should be included with EXP24S orders to indicate IBM
Manufacturing the mode to which the drawer should be set and the adapter/controller/cable
configuration which will be used. Table 2-29 lists the no-charge specify codes, the physical
adapters/controllers/cables with their own chargeable feature numbers.
Table 2-29 EXP 24S Cabling
Note:
#5887 Modes are set by IBM Manufacturing. No option to reset after IBM ships is
announced.
If ordering multiple EXP24S avoid mixing modes within that order. There is no
externally visible indicator as to the drawer's mode.
SSD are not currently supported in EXP24S .
No Cascading of #5887s - Max one #5887 per SAS connector
Power 720 or Power 740 can support up to 14 #5887
Feature code Mode Adapter/controller Cable to Drawer Environment
#9359 1 One #5278 1 YO Cable A, L,VIOS
#9360 1 Pair #5278 2 YO Cables A, L,VIOS
#9361 2 Two #5278 2 YO Cables A, L,VIOS
80 IBM Power 720 and 740: Technical Overview and Introduction
Cable to EXP 24S Drawer options:
X cables for #5278 : 3 m (#3661), 6 m (#3662), 15 m (#3663)
YO cables for #5278: 1.5 m (#3691), 3 m (#3692), 6 m (#3693), 15 m (#3694)
YI cables for system unit SAS port (3 Gb): 1.5 m (#3686) or 3 m (#3687)
For detailed information about the SAS cabling, see the serial-attached SCSI cable planning
documentation at:
http://publib.boulder.ibm.com/infocenter/powersys/v3r1m5/index.jsp?topic=/p7had/p7
hadsascabling.htm
2.13.3 TotalStorage EXP24 disk drawer and tower
The TotalStorage EXP24 is available as a 4 EIA unit drawer and mounts in a 19-inch rack
(#5786) and a tower (#5787). The front of the IBM TotalStorage EXP24 Ultra320 SCSI
Expandable Storage Disk Enclosure has bays for up to 12 disk drives organized in two SCSI
groups of up to six drives. The rear also has bays for up to 12 disk drives organized in two
additional SCSI groups of up to six drives plus slots for the four SCSI interface cards. Each
SCSI drive group can be connected by either a Single Bus Ultra320 SCSI Repeater Card
(#5741) or a Dual Bus Ultra320 SCSI Repeater Card (#5742). This allows the EXP24 to be
configured as four sets of six bays, two sets of 12 bays, or two sets of six bays plus one set of
12 bays.
The EXP24 features #5786 and #5787 have three cooling fans and two power supplies to
provide redundant power and cooling. The SCSI disk drives contained in the EXP24 are
controlled by PCI-X SCSI adapters connected to the EXP24 SCSI repeater cards by SCSI
cables. The PCI-X adapters are located in the Power 740 system unit or in an attached I/O
drawer with PCI-X slots.
The 336 system maximum is achieved with a maximum of 24 disks in a maximum of 14
TotalStorage EXP24 disk drawers (#5786) or 14 TotalStorage EXP24 disk towers (#5787).
#9365 4 Four #5278 2 X Cable A, L,VIOS
#9366 2 Two pair #5278 2 X Cables A, L,VIOS
#9367 1 Pair #5805 2 YO Cables A,i, L,VIOS
#9368 2 Two 5805 2 X Cables A, L,VIOS
#9382 1 One #5904/06/08 1 YO Cable A,i, L,VIOS
#9383 1 Pair #5904/06/08 2 YO Cables A,i, L,VIOS
#9384 1 CEC SAS port 1 YI Cable A,i, L,VIOS
Note: EXP24S Drawer rails are fixed lenght and designed to fit Power Systems provided
racks of 28 inches (8xx mm) deep. EXP24S Uses 2 EIA of space in a 19-inch wide rack.
Other racks may have different depths and these rails won't adjust. No adjustable depth
rails are orderable at this time
Feature code Mode Adapter/controller Cable to Drawer Environment
Chapter 2. Architecture and technical overview 81
2.13.4 IBM TotalStorage EXP24
The IBM 7031 TotalStorage EXP24 Ultra320 SCSI Expandable Storage Disk Enclosure
supports up to 24 Ultra320 SCSI Disk Drives arranged in four independent SCSI groups of up
to six drives or in two groups of up to twelve drives. Each SCSI drive group can be connected
by either a Single Bus Ultra320 SCSI Repeater Card or a Dual Bus Ultra320 SCSI Repeater
Card, allowing a maximum of eight SCSI connections per TotalStorage EXP24.
The IBM 7031 Model D24 (7031-D24) is an Expandable Disk Storage Enclosure that is a
horizontal 4 EIA by 19-inch rack drawer for mounting in equipment racks.
The IBM 7031 Model T24 (7031-T24) is an Expandable Disk Storage Enclosure that is a
vertical tower for floor-standing applications.
2.13.5 IBM System Storage
The IBM System Storage Disk Systems products and offerings provide compelling storage
solutions with superior value for all levels of business, from entry-level up to high-end storage
systems.
IBM System Storage N series
The IBM System Storage N series is a Network Attached Storage (NAS) solution and
provides the latest technology to customers to help them improve performance, virtualization
manageability, and system efficiency at a reduced total cost of ownership. For more
information about the IBM System Storage N series hardware and software, see:
http://www.ibm.com/systems/storage/network
IBM System Storage DS3000 family
The IBM System Storage DS3000 is an entry-level storage system designed to meet the
availability and consolidation needs for a wide range of users. New features, including larger
capacity 450 GB SAS drives, increased data protection features such as RAID 6, and more
FlashCopies per volume, provide a reliable virtualization platform. For more information about
the DS3000 family, see:
http://www.ibm.com/systems/storage/disk/ds3000/index.html
IBM System Storage DS5000
New DS5000 enhancements help reduce cost by introducing SSD drives. Also with the new
EXP5060 expansion unit supporting 60 1 TB SATA drives in a 4U package, customers can
see up to a 1/3 reduction in floor space over standard enclosures. With the addition of 1 Gbps
Note: The EXP24S SCSI disk drawer is an earlier technology drawer compared to the later
SAS EXP12S drawer. It is used to house the older SCSI disk drives that are supported, but
is no longer orderable.
Note: A new IBM 7031 TotalStorage EXP24 Ultra320 SCSI Expandable Storage Disk
Enclosure cannot be ordered for the Power 720 and Power 740, and thus only existing
7031-D24 drawers or 7031-T24 towers can be moved to the Power 720 and 740 servers.
AIX and Linux partitions are supported along with the usage of a IBM 7031 TotalStorage
EXP24 Ultra320 SCSI Expandable Storage Disk Enclosure.
82 IBM Power 720 and 740: Technical Overview and Introduction
iSCSI host attach, customers can reduce cost for their less demanding applications while
continuing to provide high performance where necessary utilizing the 8 Gbps FC host ports.
With the DS5000 family, you get consistent performance from a smarter design that simplifies
your infrastructure, improves your TCO, and reduces your cost. For more information about
the DS5000 family, see:
http://www.ibm.com/systems/storage/disk/ds5000/index.html
IBM Storwize V7000 Midrange Disk System
IBM® Storwize® V7000 is a virtualized storage system to complement virtualized server
environments that provides unmatched performance, availability, advanced functions, and
highly scalable capacity never seen before in midrange disk systems. Storwize V7000 is a
powerful midrange disk system that has been designed to be easy to use and enable rapid
deployment without additional resources. Storwize V7000 is virtual storage that offers greater
efficiency and flexibility through built-in solid state drive (SSD) optimization and thin
provisioning technologies. Storwize V7000 advanced functions also enable non-disruptive
migration of data from existing storage, simplifying implementation and minimizing disruption
to users. Storwize V7000 also enables you to virtualize and reuse existing disk systems,
supporting a greater potential return on investment (ROI). For more information about
Storwize V7000, see:
http://www.ibm.com/systems/storage/disk/storwize_v7000/index.html
IBM XIV Storage System
IBM offers a mid–sized configuration of its self-optimizing, self-healing, resilient disk solution,
the IBM XIV® Storage System: storage reinvented for a new era. Now, organizations with
mid-size capacity requirements can take advantage of IBM’s latest technology for their most
demanding applications with as little as 27TB usable capacity and incremental upgrades. For
more information about XIV, see:
http://www.ibm.com/systems/storage/disk/xiv/index.html
IBM System Storage DS8000
The IBM System Storage DS8000® family is designed to offer high availability, multiplatform
support, and simplified management tools. With its high capacity, scalability, broad server
support, and virtualization features, the DS8000 family is well suited for simplifying the
storage environment by consolidating data from multiple storage systems on a single system.
The high-end model DS8700 is the most advanced model in the IBM DS8000 family lineup
and introduces new dual IBM POWER6-based controllers that usher in a new level of
performance for the company’s flagship enterprise disk platform. The DS8700 offers twice the
maximum physical storage capacity than the previous model. For more information about the
DS8000 family, see:
http://www.ibm.com/systems/storage/disk/ds8000/index.html
2.14 Hardware Management Console
The Hardware Management Console (HMC) is a dedicated workstation that provides a
graphical user interface for configuring, operating, and performing basic system tasks for the
POWER7 processor-based, as well as the previous POWER5, POWER5+, POWER6 and
POWER6+ processor-based systems. Either non-partitioned, partitioned, or clustered
environments are supported. In addition the HMC is used to configure and manage logical
partitions (LPARs). One HMC is capable of controlling multiple POWER5, POWER5+,
POWER6 and POWER6+ and POWER7 processor-based systems.
Chapter 2. Architecture and technical overview 83
At the time of writing, one HMC supports, in general, up to 1024 LPARs using HMC machine
code Version 7 Release 710 or later. It can also support up to 48 Power 710, Power 720,
Power 730, Power 740, Power 750, Power 755, Power 770, or Power 780. Up to 32
Power 795 servers are supported. For updates of the machine code and HMC functions and
hardware prerequisites, see the following website:
http://www.ibm.com/support/fixcentral
2.14.1 HMC functional overview
The HMC provides three groups of tasks, as described in the following topics.
Server management
The first group contains all tasks related to the management of the physical servers under the
control of the HMC:
System password
Power on/off
Capacity on Demand
Error management:
– System indicators
– Error/event collection reporting
– Dump collection reporting
– Call home
– Customer notification
– Hardware replacement (guided repair)
– SNMP events
Concurrent add/repair
Redundant Service Processor
Firmware updates
Virtualization management
The second group contains all tasks related to virtualization features such as the Logical
Partition configuration or dynamic reconfiguration of resources:
System Plans
System Profiles
Logical Partitions (create, activate, shutdown)
Profiles
Partition Mobility
Dynamic LPAR operations (add/remove/move processors, memory, I/O, and so on.)
Custom Groups
HMC console management
The last group relates to the management of the HMC itself, its maintenance, security, or
configuration. Here are a few examples:
Set-up wizard
Note: The Integrated Virtualization Manager (IVM) is required to managed IBM Power
Architecture® blades. For more information, see 2.15, “Integrated Virtualization Manager”
on page 87.
84 IBM Power 720 and 740: Technical Overview and Introduction
User management:
– User IDs
– Authorization levels
– Customizable authorization
Disconnect/reconnect
Network security:
– Remote operation enable/disable
– User definable SSL certificates
Console logging
HMC redundancy
Scheduled operations
Back up and restore
Updates, upgrades
Customizable message of the day
The HMC version V7R720 adds support for Power 710, Power 720, Power 730, Power 740,
and Power 795 servers.
The HMC provides both graphical and command line interface for all management tasks.
Running HMC Version 7, a remote connection to the HMC using a web browser or SSH is
possible. A command line interface is also available by using the SSH secure shell connection
to the HMC. It can be used by an external management system or a partition to perform HMC
operations remotely.
2.14.2 HMC connectivity to the POWER7 processor based systems
POWER5, POWER5+, POWER6, POWER6+, and POWER7 processor-based servers
managed by an HMC require Ethernet connectivity between the HMC and the server Service
Processor. In addition, if dynamic LPAR, Live Partition Mobility or PowerVM Active Memory
Sharing operations are required on the managed partitions, Ethernet connectivity is needed
between these partitions and the HMC. A minimum of two Ethernet ports are needed on the
HMC to provide such connectivity. The rack-mounted 7042-CR5 and 7042-CR6 HMC default
configuration provides four Ethernet ports. The deskside 7042-C07 and 7042-C08 HMC
standard configuration offers one Ethernet port. Preferably, order an optional PCIe adapter to
provide additional Ethernet ports.
For any logical partition in a server, it is possible to use a Shared Ethernet Adapter in the
Virtual I/O Server or Logical Ports of the Integrated Virtual Ethernet card, for fewer
connections from the HMC to partitions. Therefore, a partition does not require it’s own
physical adapter to communicate to an HMC.
It is a good practice to connect the HMC to the first HMC port on the server, which is labeled
as HMC Port 1, although other network configurations are possible. You can attach a second
HMC to HMC Port 2 of the server for redundancy. Figure 2-27 shows a simple network
configuration to enable the connection from an HMC to a server in order to enable Dynamic
LPAR operations. For more details about HMC and the possible network connections, see the
Hardware Management Console V7 Handbook, SG24-7491.
Chapter 2. Architecture and technical overview 85
Figure 2-27 HMC to service processor and LPARs network connection
The default mechanism for allocation of the IP addresses for the service processor HMC
ports is dynamic. The HMC can be configured as a DHCP server, providing the IP address at
the time the managed server is powered on. In this case, the Flexible Service Processor
(FSP) is allocated IP address from a set of address ranges predefined in the HMC software.
These predefined ranges are identical for version 720 of the HMC code and for previous
versions.
If the service processor of the managed server does not receive the DHCP reply before
time-out, predefined IP addresses will be setup on both ports. Static IP address allocation is
also an option. You can also configure the IP address of the service processor ports with a
static IP address by using the Advanced System Management Interface (ASMI) menus.
Note: The service processor is used to monitor and manage the system hardware
resources and devices. The service processor offers the following connections:
Two Ethernet 10/100 Mbps ports are provided:
Both Ethernet ports are only visible to the service processor and can be used to attach
the server to an HMC or to access the Advanced System Management Interface
(ASMI) options from a client web browser, using the http server integrated into the
service processor internal operating system.
When not configured otherwise (DHCP or from a previous ASMI setting), both Ethernet
ports of the first FSP have predefined IP addresses:
– Service processor Eth0 or HMC1 port is configured as 169.254.2.147 with netmask
255.255.255.0
– Service processor Eth1 or HMC2 port is configured as 169.254.3.147 with netmask
255.255.255.0
More information about the Service Processor can be found in “Service processor” on
page 144.
86 IBM Power 720 and 740: Technical Overview and Introduction
2.14.3 HMC high availability
The Hardware Management Console (HMC) is an important hardware component. When put
into operation, POWER7 processor-based servers and their hosted partitions can continue to
operate when no HMC is available. However, in such conditions, certain operations cannot be
performed, such as a DLPAR reconfiguration, a partition migration using PowerVM Live
Partition Mobility, or the creation of a new partition. You can therefore choose install two
HMCs in a redundant configuration so that one HMC is always operational. For example,
when performing maintenance of one HMC, the other is still operational.
If redundant HMC function is desired, the servers can be attached to two separate HMCs to
address availability requirements. Both HMCs must have the same level of Hardware
Management Console Licensed Machine Code Version 7 (#0962) to manage POWER7
processor-based servers or an environment with a mixture of POWER5, POWER5+,
POWER6, POWER6+ and POWER7 processor-based servers. The HMCs provide a locking
mechanism so that only one HMC at a time has write access to the service processor.
Depending on your environment, you have multiple options to configure the network.
Figure 2-28 shows one possible highly available HMC configuration managing two servers.
Each HMC is connected to one FSP port of all managed servers.
Figure 2-28 Highly available HMC and network architecture
Only the hardware management networks (LAN1 and LAN2) are shown as highly available in
this diagram for simplicity. However, the management network (LAN3) can be made highly
available by using a similar concept and adding more Ethernet adapters to LPARs and HMCs.
Both HMCs must be on a separate VLAN, to protect from a network failure. Each HMC can be
a DHCP server for its VLAN.
In a configuration with multiple systems or HMCs, the customer is required to provide
switches or hubs to connect each HMC to the server FSP Ethernet ports in each system. One
HMC must connect to the port labeled as HMC Port 1, and a second HMC must be attached
to HMC Port 2. This provides redundant connections for the HMCs and the service processor.
HMC1 HMC2
System A System B
1 2
FSP
1 2
FSP
LAN 1 LAN 2
LPAR A1
LPAR A2
LPAR A3
LPAR B1
LPAR B2
LPAR B3
eth0eth1
eth0eth1
LAN1 – Hardware management network for
first FSP ports (private)
LAN2 – Hardware management network for
second FSP ports (private), separate
network hardware than LAN1
LAN3 - Open network for HMC access and
dLPAR operations
LAN3 – Open network
Chapter 2. Architecture and technical overview 87
For more details about redundant HMCs, see the Hardware Management Console V7
Handbook, SG24-7491.
2.14.4 HMC code level
The HMC code must be at level V7R720 in order to support the Power 720 and Power 740
systems.
In a dual HMC configuration, both HMCs need to be at the same version and release of the
HMC.
Here we list two important rules related to HMC code level when using PowerVM Live
Partition Mobility:
To use PowerVM Live Partition Mobility between a POWER6 processor-based server and
a POWER7 processor-based server, if the source server is managed by one HMC and the
destination server is managed by another HMC, then ensure that the HMC managing the
POWER6 processor-based server is at version 7, release 3.5 or later, and the HMC
managing the POWER7 processor-based server is at version 7, release 7.1 or later.
To use PowerVM Live Partition Mobility for a partition configured for Active Memory
Expansion, ensure that the HMC that manages the destination server is at version 7,
release 7.1 or later.
2.15 Integrated Virtualization Manager
The Integrated Virtualization Manager (IVM) is a simplified hardware management solution
that inherits most of the HMC features. The IVM runs within the Virtual I/O Server partition on
the managed server. It manages a single server, avoiding the need of an independent
appliance. It is designed to provide a solution that enables the administrator to reduce system
setup time and to make hardware management easier, at a lower cost.
IVM provides a management model for a single system. Although it does not offer all of the
HMC capabilities, it enables the exploitation of PowerVM technology. IVM targets the small
and medium systems environment. The following POWER7 processor-based servers can be
managed by IVM:
Power 710
Tip: When upgrading the code of an HMC in a dual HMC configuration, it is a good
practice to disconnect one of the HMCs and avoid having both HMCs connected to the
same server with various code levels. If no profile or partition changes take place during
the upgrade, both HMCs can stay connected. If the HMCs are at various code levels and a
profile change is performed from the HMC at the higher code level, the format of the data
stored in the server can change, and the HMC at the lower code level might go into
recovery state if it does not understand the new data format.
Tip: There are compatibility rules between the various software products that are
executing within a POWER7 processor-based server environment: HMC, Virtual I/O
Server, system firmware or partition operating systems. To check what combinations are
supported, and to identify required upgrades, you can use the Fix Level Tool web page:
http://www14.software.ibm.com/webapp/set2/flrt/home
88 IBM Power 720 and 740: Technical Overview and Introduction
Power 720
Power 730
Power 740
Power 750
IVM is an addition to the Virtual I/O Server (VIOS), the product that enables I/O virtualization
in the family of POWER processor-based systems. The IVM functions are provided by
software executing within the Virtual I/O Server partition installed on the server to manage.
Note: In order to manage a Power 720 and Power 740 system through IVM, the Virtual I/O
Server Version 2.2 is required.
Chapter 2. Architecture and technical overview 89
Table 2-30 lists a detailed comparison between the IVM and the HMC functions.
Table 2-30 Comparison between IVM and HMC
Characteristics and
functions
IVM HMC
General characteristics
Delivery Vehicle Integrated into the server A desktop or rack-mounted
appliance
Installation Installed with the Virtual I/O
Server (optical or network). The
preinstall option is available on
certain systems.
Appliance is preinstalled.
Reinstall by optical media or
network is supported.
Multiple system support One IVM per server One HMC can manage multiple
servers
User Interface Web browser (no local
graphical display) and telnet
session
Web browser (local or remote)
or SSH access
Scripting and Automation VIOS command line interface
(CLI) and HMC compatible CLI
HMC command line interface
RAS characteristics
Redundancy/HA of manager One IVM per server Multiple HMCs can manage the
same system for HMC
redundancy
Multiple VIOS No – single VIOS Yes
Fix/Update process for
Manager
VIOS fixes and updates HMC e-fixes and release
updates
Adapter microcode updates Inventory scout by RMC Inventory scout by RMC
Firmware updates Inband by OS – not concurrent IBM Service Focal Point™
with concurrent firmware
maintenance
I/O Concurrent Maintenance VIOS support for slot and
device level concurrent
maintenance by the diag hot
plug support
Guided support in the “Repair
and Verify” function on the HMC
Serviceable event management Service Focal Point Light -
Consolidated management of
firmware and management
partition detected errors
Service Focal Point support for
consolidated management of
operating system and firmware
detected errors
PowerVM function
Full PowerVM Capability Partial Full
Capacity on Demand Entry of PowerVM codes only Full Support
I/O Support for IBM i Virtual Only Virtual and Direct
Multiple Shared Processor Pool No - default pool only Yes
Workload Management (WLM)
Groups Supported
One 254
90 IBM Power 720 and 740: Technical Overview and Introduction
For a complete description of the possibilities offered by IVM, see Integrated Virtualization
Manager on IBM System p5, REDP-4061.
2.15.1 IBM Systems Director Management Console (SDMC)
IBM Systems Director Management Console (SDMC) V6.7.3 is the next-generation Hardware
Management Console (HMC). The SDMC incorporates the IBM Systems Director software to
provide consistency with IBM Systems Director on other platforms.
The SDMC is available on physical hardware that is identical to that of the current HMC with
additional memory and disk resources. SDMC is also available in a virtual appliance format
for managing small-tier servers. The SDMC offers several advantages over the HMC,
including the ability to manage both Power Systems servers and Power Systems blades
based on Power Architecture®.
The SDMC is intended to be used in the same manner as the HMC. It provides the same
functionality, including hardware, service, and virtualization management, for your Power
Systems server and Power Systems blades. Because SDMC uses IBM Systems Director
Express® Edition, it also provides all Systems Director Express capabilities, such as
monitoring of operating systems and creating event action plans.
The SDMC can be obtained as a hardware appliance in the same manner as an HMC.
Hardware appliances support managing Power Systems servers. The SDMC can optionally
be obtained in a virtual appliance format, capable of running on VMware (ESX/i 4, or later),
and KVM (Red Hat Enterprise Linux® (RHEL) 5.5). The virtual appliance is only supported
for managing small-tier Power® servers and Power Systems blades. Much of the SDMC
function is equivalent to the HMC. This includes:
Server (host) management: Like HMC, the SDMC server (host) management functions
include power control, inventory collection, firmware management including concurrent
updates, error reporting, dump retrieval and transmission, error reporting via Call Home,
and component repair and verify.
Virtualization management: Like HMC, the SDMC virtualization management function
includes management of logical partitions (virtual servers) and virtual I/ O,
Micro-PartitioningTM, Partition (Virtual Server) Mobility, Partition (virtual server) Suspend
and Resume, Active MemoryTM Sharing, N_Port ID Virtualization (NPIV), HCA (IB)
configuration, and other PowerVMTM capabilities.
Transition of configuration data: All partition (virtual server) related information is stored on
the managed system itself and will be maintained as is. No configuration changes are
required when a client moves from HMC management to SDMC management.
Redundancy and high availability: The SDMC offers console redundancy similar to the
HMC. The SDMC may be used in either an SDMC-SDMC pair or an SDMC- HMC pair.
Alternatively, the SDMC may be configured as an Active-Passive High Availability pair. The
Active-Passive HA function provides high availability for Systems Director operating
system management functions.
Support for multiple profiles per
partition
No Yes
SysPlan Deploy & mksysplan Yes Yes
Characteristics and
functions
IVM HMC
Chapter 2. Architecture and technical overview 91
While most functions that SDMC provides are very similar to that of the HMC, the SDMC has
made significant strides in simplifying virtualization management. Specifically, managing
virtual I/O has become much simpler as SDMC can automatically create virtual I/O adapters,
and allow the user to assign virtual storage directly to partitions (virtual servers). SDMC
provides a more intuitive interface for dynamically managing the resources currently
assigned to a partition (virtual server), by combining the HMC DLPAR functions with partition
(virtual server) properties. SDMC also allows partition (virtual server) modifications
independent of the partition (virtual server) state.
Another significant enhancement is the ability of the SDMC to manage Power Systems
blades. While IVM is still a choice for Power Systems blade management, clients choosing
SDMC management of blades can take advantage of multiple Virtual I/O Servers, multiple
shared processor pools, Active Memory Expansion, Partition (virtual server) Suspend and
Resume, and many other PowerVM capabilities.
Because SDMC uses Systems Director, you can take advantage of all that Systems Director
Express Edition has to offer with respect to managing Power Systems servers and blades.
Highlights include:
Operating system management: Use SDMC to discover and directly manage your
operating systems.
Event automation plans: Create automation plans that perform specific functions on a
given event. For example, when the CPU utilization exceeds a given threshold, an email
notification can be sent to an administrator.
Dashboard: The SDMC provides a dashboard with health and status.
Monitoring: Systems Director brings a richer set of monitoring functions to the
management console.
Common look and feel of the IBM Systems Director portfolio family.
The Systems Director Management Console Virtual Appliance (5765-MCV) does not
include support for the customer-installed hypervisor. If you use the SDMC Virtual Appliance,
you will need to purchase KVM or VMware support separately if you want to have support for
your hypervisor.
Migration, updates, and compatibility: IBM does not support upgrades or conversions
from existing CR5/CR6 hardware-based Hardware Management Consoles to the
Systems Director Management Console.
Differences from HMC: The following functions provided by the HMC are not provided by
the SDMC: modem support and VPN call home. Also, POWER5 technology-based servers
are not supported by the SDMC.
For a complete description of the possibilities offered by SDMC, see IBM Systems Director
Management Console: Introduction and Overview, SG24-7860-00 available at web page:
http://www.redbooks.ibm.com/abstracts/sg247860.html?Open
2.16 Operating system support
The IBM POWER7 processor-based systems support three families of operating systems:
AIX
IBM i
Linux
92 IBM Power 720 and 740: Technical Overview and Introduction
In addition, the Virtual I/O Server can be installed in special partitions that provide support to
the other operating systems for using features such as virtualized I/O devices, PowerVM Live
Partition Mobility, and/or PowerVM Active Memory Sharing.
2.16.1 Virtual I/O Server
The minimum required level of Virtual I/O Server software depends on the server model:
Power 710 and 730 Virtual I/O Server Version 2.2, or later
Power 720 and 740 Virtual I/O Server Version 2.2, or later
Power 750 Virtual I/O Server Version 2.1.2.11 with Fix Pack 22.1 and Service
Pack 1
Power 755 The Virtual I/O Server feature is not available on this model.
Power 770 and 780 Virtual I/O Server Version 2.1.2.12 with Fix Pack 22.1 and Service
Pack 2
Power 795 Virtual I/O Server Version 2.2, or later
IBM regularly updates the Virtual I/O Server code. To find information about the latest
updates, visit the Virtual I/O Server site:
http://www14.software.ibm.com/webapp/set2/sas/f/vios/documentation/home.html
2.16.2 IBM AIX operating system
The following sections discuss the support for the various levels of AIX operating system
support.
IBM periodically releases maintenance packages (service packs or technology levels) for the
AIX operating system. Information about these packages, downloading, and obtaining the
CD-ROM is on the Fix Central Web site:
http://www-933.ibm.com/support/fixcentral/
The Fix Central Web site also provides information about ho to obtain the fixes shipping on
CD-ROM.
The Service Update Management Assistant, which can help you to automate the task of
checking and downloading operating system downloads, is part of the base operating system.
For more information about the suma command, go to following Web site:
http://www14.software.ibm.com/webapp/set2/sas/f/genunix/suma.html
IBM AIX Version 5.3
IBM AIX Version 5.3 is supported on all models of POWER7 processor-based servers
delivered in 2010.
The minimum level of AIX Version 5.3 to support the Power 710, 720, 730, and 740 is:
AIX 5.3 with the 5300-10 Technology Level and Service Pack 5, or later
AIX 5.3 with the 5300-11 Technology Level and Service Pack 5, or later
Note: For details about the software available on IBM POWER servers, visit the Power
Systems Software™ site:
http://www.ibm.com/systems/power/software/index.html
Chapter 2. Architecture and technical overview 93
AIX 5.3 with the 5300-12 Technology Level and Service Pack 2, or later
The minimum level of AIX Version 5.3 to support the Power 750, 755, 770, and 780 is:
AIX 5.3 with the 5300-09 Technology Level and Service Pack 7, or later
AIX 5.3 with the 5300-10 Technology Level and Service Pack 4, or later
AIX 5.3 with the 5300-11 Technology Level and Service Pack 2, or later
The minimum level of AIX Version 5.3 to support the Power 795 is:
AIX 5.3 with the 5300-10 Technology Level and Service Pack 5, or later
AIX 5.3 with the 5300-11 Technology Level and Service Pack 5, or later
AIX 5.3 with the 5300-12 Technology Level and Service Pack 1, or later
A partition using AIX Version 5.3 will be executing in POWER6 or POWER6+ compatibility
mode. This means that although the POWER7 processor has the ability to run four hardware
threads per core simultaneously, using AIX 5.3 limits the number of hardware threads per
core to two.
A partition with AIX 5.3 is limited to a maximum of 64 cores.
IBM AIX Version 6.1
If you install AIX 6.1 on a POWER7 processor-based server, the minimum level requirements
depend on the target server model:
The minimum level of AIX Version 6.1 to support the Power 710, 720, 730, 740, and 795 is:
AIX 6.1 with the 6100-04 Technology Level and Service Pack 7, or later
AIX 6.1 with the 6100-05 Technology Level and Service Pack 3, or later
AIX 6,1 with the 6100-06 Technology Level
The minimum level of AIX Version 6.1 to support the Power 750 and 755 is:
AIX 6.1 with the 6100-02 Technology Level and Service Pack 8, or later
AIX 6.1 with the 6100-03 Technology Level and Service Pack 5, or later
AIX 6.1 with the 6100-04 Technology Level and Service Pack 2, or later
The minimum level of AIX Version 6.1 to support the Power 770 and 780 is:
AIX 6.1 with the 6100-02 Technology Level and Service Pack 8, or later
AIX 6.1 with the 6100-03 Technology Level and Service Pack 5, or later
AIX 6.1 with the 6100-04 Technology Level and Service Pack 3, or later
A partition using AIX 6.1 with TL6 can run in POWER6, POWER6+ or POWER7 mode. It is
best to run the partition in POWER7 mode to allow exploitation of new hardware capabilities
such as SMT4 and Active Memory Expansion (AME).
A partition with AIX 6.1 is limited to a maximum of 64 cores.
IBM AIX Version 7.1
AIX Version 7.1 comes will full support for the Power 710, 720, 730, 740, 750, 755, 770, 780,
and 795, exploiting all the hardware features from the POWER7 processor, as well as from
the server architecture. A partition with AIX 7.1 can run in POWER6, POWER6+ or POWER7
mode, to enable Live Partition Mobility to different POWER6 and POWER7 systems. When
94 IBM Power 720 and 740: Technical Overview and Introduction
running in POWER7 mode, a partition with AIX 7.1 can scale up to 256 cores and 8 TB of
RAM.
2.16.3 IBM i operating system
The IBM i operating system is supported on Power 710, 720, 730, 740, 750, 770, 780, and
795 at the following minimum levels:
IBM i Version 6.1 with i 6.1.1 machine code, or later
IBM i Version 7.1, or later
IBM i Standard Edition, and Application Server Edition options are available the Power 740,
750, 770, 780, and 795.
IBM i Standard Edition offers an integrated operating environment for business processing
IBM i Application Server Edition offers IBM i without DB2 for application and infrastructure
serving.
IBM i is not supported on Power 755.
IBM periodically releases maintenance packages (service packs or technology levels) for the
IBM i operating system. Information about these packages, downloading, and obtaining the
CD-ROM is on the Fix Central Web site:
http://www-933.ibm.com/support/fixcentral/
2.16.4 Linux operating system
Linux is an open source operating system that runs on numerous platforms from embedded
systems to mainframe computers. It provides a UNIX-like implementation across many
computer architectures.
The supported versions of Linux on POWER7 processor-based servers are:
SUSE Linux Enterprise Server 10 with SP3, enabled to run in POWER6 Compatibility
mode
SUSE Linux Enterprise Server 11, supporting POWER6 or POWER7 mode
Red Hat Enterprise Linux AP 5 Update 5 for POWER, or later
Clients wanting to configure Linux partitions in virtualized Power Systems have to be aware of
these conditions:
Not all devices and features that are supported by the AIX operating system are supported
in logical partitions running the Linux operating system.
Linux operating system licenses are ordered separately from the hardware. You may
acquire Linux operating system licenses from IBM, to be included with the POWER7
processor-based servers, or from other Linux distributors.
Note: Partition sizes greater than 128-cores (up to 256-cores) will require a software key to
enable. Purchase will require lab services pre-analysis as a prerequisite to shipment. The
software key requires feature #1256 to be installed.
Chapter 2. Architecture and technical overview 95
For information about the features and external devices supported by Linux, go to:
http://www.ibm.com/systems/p/os/linux/index.html
For information about SUSE Linux Enterprise Server 10, go to:
http://www.novell.com/products/server
For information about Red Hat Enterprise Linux Advanced Server, go to:
http://www.redhat.com/rhel/features
Supported virtualization features are listed in 3.5.9, “Operating System support for
PowerVM”.
2.17 Compiler technology
You can boost performance and productivity with IBM compilers on IBM Power Systems.
IBM XL C, XL C/C++ and XL FORTRAN compilers for AIX and for Linux exploit the latest
POWER7 processor architecture. Release after release, these compilers continue to help
improve application performance and capability, exploiting architectural enhancements made
available through the advancement of the POWER® technology.
IBM compilers are designed to optimize and tune your applications for execution on IBM
POWER platforms, to help you unleash the full power of your IT investment, to create and
maintain critical business and scientific applications, to maximize application performance,
and to improve developer productivity. The performance gain from years of compiler
optimization experience is seen in the continuous release-to-release compiler improvements
that support the POWER4 processors, through to the POWER4+, POWER5, POWER5+ and
POWER6 processors, and now including the new POWER7 processors. With the support of
the latest POWER7 processor chip, IBM advances a more than 20-year investment in the XL
compilers for POWER series and PowerPC series architectures.
The XL C, XL C/C++ and XL FORTRAN features introduced to exploit the latest POWER7
processor include vector unit and vector scalar extension (VSX) instruction set to efficiently
manipulate vector operations in your application, vector functions within the Mathematical
Acceleration Subsystem (MASS) libraries for improved application performance, built-in
functions or intrinsics and directives for direct control of POWER instructions at the
application level, and architecture and tuning compiler options to optimize and tune your
applications.
COBOL for AIX enables you to selectively target code generation of your programs to either
exploit POWER7 systems architecture or to be balanced among all supported POWER
systems. The performance of COBOL for AIX applications is improved by means of an
enhanced back-end optimizer. The back-end optimizer, a component common also to the
IBM XL compilers, lets your applications leverage the latest industry-leading optimization
technology.
PL/I for AIX supports application development on the latest POWER7 processor.
IBM Rational® Development Studio for IBM i 7.1 provides programming languages for
creating modern business applications. This includes the ILE RPG, ILE COBOL, C, and C++
compilers as well as the heritage RPG and COBOL compilers. The latest release includes
performance improvements and XML processing enhancements for ILE RPG and ILE
COBOL, improved COBOL portability with a new COMP-5 data type, and easier Unicode
migration with relaxed USC2 rules in ILE RPG. Rational has also released a new product
96 IBM Power 720 and 740: Technical Overview and Introduction
called Rational Open Access: RPG Edition. This opens up the ILE RPG file I/O processing,
enabling partners, tool providers, and users to write custom I/O handlers that can access
other devices such as databases, services, and Web user interfaces.
IBM Rational Developer for Power Systems Software provides a rich set of integrated
development tools that support the XL C/C++ for AIX compiler, the XL C for AIX compiler and
the COBOL for AIX compiler. Rational Developer for Power Systems Software offers
capabilities of file management, searching, editing, analysis, build, and debug, all integrated
into an Eclipse workbench. XL C/C++, XL C and COBOL for AIX developers can boost
productivity by moving from older, text-based, command line development tools to a rich set
of integrated development tools.
IBM Rational Power Appliance is a preconfigured application development environment
solution for Power Systems, which includes a Power Express server preinstalled with a
comprehensive set of Rational development software along with the AIX operating system.
The Rational development software includes support for Collaborative Application Lifecycle
Management (C/ALM) through Rational Team Concert for Power Systems Software, a set of
software development tools from Rational Developer for Power Systems Software, and a
choice between the XL C/C++ for AIX or COBOL for AIX compilers.
2.18 Energy management
The Power 720 and 740 servers are designed with features to help clients become more
energy efficient. The IBM Systems Director Active Energy Manager exploits EnergyScale
technology, enabling advanced energy management features to dramatically and dynamically
conserve power and further improve energy efficiency. Intelligent Energy optimization
capabilities enable the POWER7 processor to operate at a higher frequency for increased
performance and performance per watt or dramatically reduce frequency to save energy.
2.18.1 IBM EnergyScale technology
IBM EnergyScale technology provides functions to help the user understand and dynamically
optimize the processor performance versus processor energy consumption, and system
workload, to control IBM Power Systems power and cooling usage.
On POWER7 processor-based systems, the thermal power management device (TPMD)
card is responsible for collecting the data from all system components, changing operational
parameters in components, and to interact with the IBM Systems Director Active Energy
Manager (an IBM Systems Directors plug-in) for energy management and control.
IBM EnergyScale makes use of power and thermal information collected from the system in
order to implement policies that can lead to better performance, or better energy utilization.
IBM EnergyScale features include:
Power trending
EnergyScale provides continuous collection of real-time server energy consumption. This
enables administrators to predict power consumption across their infrastructure and to react
to business and processing needs. For example, administrators can use such information to
predict datacenter energy consumption at various times of the day, week, or month.
Chapter 2. Architecture and technical overview 97
Thermal reporting
IBM Director Active Energy Manager can display measured ambient temperature and
calculated exhaust heat index temperature. This information can help identify data center hot
spots that need attention.
Power Saver Mode
Power Saver Mode lowers the processor frequency and voltage on a fixed amount, reducing
the energy consumption of the system while still delivering predictable performance. This
percentage is predetermined to be within a safe operating limit and is not user configurable.
The server is designed for a fixed frequency drop of up to 30% down from nominal frequency
(the actual value depends on the server type and configuration). Power Saver Mode is not
supported during boot or re-boot although it is a persistent condition that will be sustained
after the boot when the system starts executing instructions.
Dynamic Power Saver Mode
Dynamic Power Saver Mode varies processor frequency and voltage based on the utilization
of the POWER7 processors. Processor frequency and utilization are inversely proportional for
most workloads, implying that as the frequency of a processor increases, its utilization
decreases, given a constant workload.Dynamic Power Saver Mode takes advantage of this
relationship to detect opportunities to save power, based on measured real-time system
utilization.
When a system is idle, the system firmware will lower the frequency and voltage to Power
Energy Saver Mode values. When fully utilized, the maximum frequency will vary, depending
on whether the user favors power savings or system performance. If an administrator prefers
energy savings and a system is fully-utilized, the system is designed to reduce the maximum
frequency to 95% of nominal values. If performance is favored over energy consumption, the
maximum frequency can be increased to up to 109% of nominal frequency for extra
performance.
Dynamic Power Saver Mode is mutually exclusive with Power Saver mode. Only one of these
modes can be enabled at a given time.
Power Capping
Power Capping enforces a user-specified limit on power usage. Power Capping is not a power
saving mechanism. It enforces power caps by actually throttling the processors in the system,
degrading performance significantly. The idea of a power cap is to set a limit that must never
be reached but frees up extra power never used in the data center. The margined power is
this amount of extra power that is allocated to a server during its installation in a datacenter. It
is based on the server environmental specifications that usually are never reached because
server specifications are always based on maximum configurations and worst case
scenarios. The user must set and enable an energy cap from the IBM Director Active Energy
Manager user interface.
Soft Power Capping
There are two power ranges into which the power cap can be set; one is Power Capping as
described before, and the other is Soft Power Capping. Soft Power Capping extends the
allowed energy capping range further, beyond a region that can be guaranteed in all
configurations and conditions. If the energy management goal is to meet a particular
consumption limit, then Soft Power Capping is the mechanism to use.
98 IBM Power 720 and 740: Technical Overview and Introduction
Processor Core Nap Mode
The IBM POWER7 processor uses a low-power mode called Nap that stops processor
execution when there is no work to do on that processor core. The latency of exiting Nap is
very small, typically not generating any impact on applications running. Because of that,
the POWER Hypervisor can use the Nap mode as a general purpose idle state. When the
operating system detects that a processor thread is idle, it yields control of a hardware thread
to the POWER Hypervisor. The POWER Hypervisor immediately puts the thread into Nap
mode. Nap mode allows the hardware to turn the clock off on most of the circuits inside the
processor core. Reducing active energy consumption by turning off the clocks allows the
temperature to fall, which further reduces leakage (static) power of the circuits causing a
cumulative effect. Nap mode saves from 10-15% of power consumption in the processor core.
Processor core Sleep Mode
To be able to save even more energy, the POWER7 processor has an even lower power mode
called Sleep. Before a core and its associated L2 and L3 caches enter Sleep mode, caches
are flushed and transition lookaside buffers (TLB) are invalidated, and hardware clock is
turned off in the core and in the caches. Voltage is reduced in order to minimize leakage
current. Processor cores inactive in the system (such as CoD processor cores) are kept in
Sleep mode. Sleep mode saves about 35% power consumption in the processor core and
associated L2 and L3 caches.
Fan control and altitude input
System firmware will dynamically adjust fan speed based on energy consumption, altitude,
ambient temperature, and energy savings modes. Power Systems are designed to operate in
worst-case environments, in hot ambient temperatures, at high altitudes, and with high power
components. In a typical case, one or more of these constraints are not valid. When no power
savings setting is enabled, fan speed is based on ambient temperature, and assumes a
high-altitude environment. When a power savings setting is enforced (either Power Energy
Saver Mode or Dynamic Power Saver Mode), fan speed will vary based on power
consumption, ambient temperature, and altitude available. System altitude can be set in IBM
Director Active Energy Manager. If no altitude is set, the system will assume a default value of
350 meters above sea level.
Processor Folding
Processor Folding is a consolidation technique that dynamically adjusts, over the short-term,
the number of processors available for dispatch to match the number of processors
demanded by the workload. As the workload increases, the number of processors made
available increases; as the workload decreases, the number of processors made available
decreases. Processor Folding increases energy savings during periods of low to moderate
workload because unavailable processors remain in low-power idle states (Nap or Sleep)
longer.
EnergyScale for I/O
IBM POWER7 processor-based systems automatically power off hot pluggable, PCI adapter
slots that are empty or not being used. System firmware automatically scans all pluggable
PCI slots at regular intervals, looking for those that meet the criteria for being not in use and
powering them off. This support is available for all POWER7 processor-based servers, and
the expansion units that they support.
Server Power Down
If overall data center processor utilization is low, workloads can be consolidated on fewer
numbers of servers so that some servers can be turned off completely. It makes sense to do
this when there will be long periods of low utilization, such as weekends. AEM provides
Chapter 2. Architecture and technical overview 99
information, such as the power that will be saved and the time it will take to bring a server
back online, that can be used to help make the decision to consolidate and power off. As with
many of the features available in IBM Systems Director and Active Energy Manager, this
function is scriptable and can be automated.
Partition Power Management
Available with Active Energy Manager 4.3.1 or newer, and POWER7 systems with EM730
firmware or newer, is the capability to set a power savings mode for partitions or the system
processor pool. As ith the system-level power savings modes, the per-partition power savings
modes can be used to achieve a balance between the power consumption and the
performance of a partition. Only partitions that have dedicated processing units can have a
unique power savings setting. Partitions that run in shared processing mode will have a
common power savings setting, which is that of the system processor pool. This is because
processing unit fractions cannot be power-managed.
As in the case of system-level power savings, two Dynamic Power Saver options are offered:
favor partition performance, or favor partition power savings. The user must configure this
setting from Active Energy Manager. When Dynamic Power Saver is enabled in either mode,
system firmware continuously monitors the performance and utilization of each of the
computer's POWER7 processor cores that belong to the partition. Based on this utilization
and performance data, the firmware will dynamically adjust the processor frequency and
voltage, reacting within milliseconds to adjust workload performance and also deliver power
savings when the partition is under-utilized.
In addition to the two Dynamic Power Saver options, the customer can select to have no
power savings on a given partition. This option will leave the processor cores assigned to the
partition running at their nominal frequencies and voltages.
A new power savings mode, called “Inherit Host Setting”, is available and is only applicable to
partitions. When configured to use this setting, a partition will adopt the power savings mode
of its hosting server. By default, all partitions with dedicated processing units, and the system
processor pool, are set to Inherit Host Setting.
On POWER7 processor-based systems, several EnergyScales are imbedded in the hardware
and do not require an operating system or external management component. More advanced
functionality requires Active Energy Manager (AEM) and IBM Systems Director.
Table 2-31 provides a list of all features actually supported, underlining all cases where AEM
is not required. The table details also the features that can be activated by traditional user
interfaces (ASMI, HMC).
Table 2-31 AEM support
Feature Active Energy Manager (AEM) required ASMI HMC
Power Trending Y N N
Thermal Reporting Y N N
Static Power Saver N Y Y
Dynamic Power Saver Y N N
Power Capping Y N N
Energy-optimized Fans N - -
Processor Core Nap N - -
100 IBM Power 720 and 740: Technical Overview and Introduction
The Power 720 and Power 740 systems implement all the Energy Scale capabilities listed in
2.18.1, “IBM EnergyScale technology” on page 96.
2.18.2 Thermal power management device card
The thermal power management device (TPMD) card is a separate microcontroller installed
on some POWER6 processor-based systems, and in all POWER7 processor-based systems.
It runs real-time firmware whose sole purpose is to manage system energy.
The TPMD card monitors the processor modules, memory, environmental temperature, and
fan speed; and based on this information, it can act upon the system to maintain optimal
power and energy conditions (for example, increase the fan speed to react to a temperature
change). It also interacts with the IBM Systems Director Active Energy Manager to report
power and thermal information, and to receive input from AEM on policies to be set. The
TPMD is part of the EnergyScale infrastructure.
Processor Core Sleep N - -
Processor Folding N - -
EnergyScale for I/O N - -
Server Power Down Y - -
Partition Power
Management
Y - -
Feature Active Energy Manager (AEM) required ASMI HMC
© Copyright IBM Corp. 2010. All rights reserved. 101
Chapter 3. Virtualization
As you look for ways to maximize the return on your IT infrastructure investments,
consolidating workloads becomes an attractive proposition.
IBM Power Systems combined with PowerVM technology are designed to help you
consolidate and simplify your IT environment, with the following key capabilities:
Improve server utilization and sharing I/O resources to reduce total cost of ownership and
make better use of IT assets.
Improve business responsiveness and operational speed by dynamically re-allocating
resources to applications as needed — to better match changing business needs or
handle unexpected changes in demand.
Simplify IT infrastructure management by making workloads independent of hardware
resources, thereby enabling you to make business-driven policies to deliver resources
based on time, cost, and service-level requirements.
This chapter discusses the virtualization technologies and features on IBM Power Systems:
POWER Hypervisor
POWER Modes
Partitioning
Active Memory Expansion
PowerVM
System Planning Tool
3
102 IBM Power 720 and 740: Technical Overview and Introduction
3.1 POWER Version 2.2 enhancements
The latest available PowerVM Version 2.2 contains the following enhancements:
Support for up to 80 LPARs on Power 710 and 720
Support for up to 160 LPARs on Power 730, 740,
Support for up to 320 LPARs on Power 750,
Support for up to 640 LPARs on Power 770 and 780
Support for up to 1024 LPARs on Power 795
PowerVM support for sub-chip per-core licensing on Power 710, 720, 730, and 740
Role Based Access Control (RBAC):
RBAC brings an added level of security and flexibility in the administration of VIOS. With
RBAC, you can create a set of authorizations for the user management commands. You
can assign these authorizations to a role UserManagement and this role can be given to
any other user. So a normal user with the role UserManagement can manage the users on
the system but will not have any further access.
With RBAC, the Virtual I/O Server has the capability of split management functions that
presently can be done only by the padmin user, providing better security by giving only the
necessary access to users, and easy management and auditing of system functions.
Support for Concurrent Add of VLANs
Support for USB tape:
The Virtual I/O Server now supports a USB DAT-320 Tape Drive and its use as a virtual
tape device for VIOS clients.
Support for USB Blu-ray:
The Virtual I/O Server now supports USB Blu-ray optical devices. AIX does not support
mapping these as virtual optical devices to clients. However, you can import the disk into
the virtual optical media library and map the created file to the client as a virtual DVD
drive.
The IBM PowerVM Workload Partitions Manager™ for AIX, Version 2.2 has the following
enhancements:
When used with AIX 6.1 Technology Level 6, the following support applies:
– Support for exporting VIOS SCSI disk into a WPAR. Compatibility analysis and mobility
of WPARs with VIOS SCSI disk. In addition to Fibre Channel devices, now VIOS SCSI
disks can be exported into a workload partition (WPAR).
– WPAR Manager Command-Line Interface (CLI). The WPAR Manager CLI allows
federated management of WPARs across multiple systems by command line.
– Support for workload partition definitions. The WPAR definitions can be preserved after
WPARs are deleted. These definitions can be deployed at a later time to any
WPAR-capable system.
In addition to the feature supported on AIX 6.1 Technology Level 6, the following applies to
AIX 7.1:
– Support for AIX 5.2 Workload Partitions for AIX 7.1. Life cycle management and
mobility enablement for AIX 5.2 Technology Level 10 SP8 Version WPARs.
– Support for trusted kernel extension loading and configuration from WPARs. Enables
exporting a list of kernel extensions that can then be loaded inside a WPAR, yet
maintaining isolation.
Chapter 3. Virtualization 103
3.2 POWER Hypervisor
Combined with features designed into the POWER7 processors, the POWER Hypervisor
delivers functions that enable other system technologies, including logical partitioning
technology, virtualized processors, IEEE VLAN compatible virtual switch, virtual SCSI
adapters, virtual Fibre Channel adapters, and virtual consoles. The POWER Hypervisor is a
basic component of the system’s firmware and offers the following functions:
Provides an abstraction between the physical hardware resources and the logical
partitions that use them
Enforces partition integrity by providing a security layer between logical partitions
Controls the dispatch of virtual processors to physical processors (see “Processing Mode”
on page 114)
Saves and restores all processor state information during a logical processor context
switch
Controls hardware I/O interrupt management facilities for logical partitions
Provides virtual LAN channels between logical partitions that help to reduce the need for
physical Ethernet adapters for inter-partition communication
Monitors the Service Processor and will perform a reset/reload if it detects the loss of the
Service Processor, notifying the operating system if the problem is not corrected
The POWER Hypervisor is always active, regardless of the system configuration and also
when not connected to the HMC. It requires memory to support the resource assignment to
the logical partitions on the server. The amount of memory required by the POWER
Hypervisor firmware varies according to several factors. Here we list factors influencing the
POWER Hypervisor memory requirements:
Number of logical partitions
Number of physical and virtual I/O devices used by the logical partitions
Maximum memory values specified in the logical partition profiles
The minimum amount of physical memory to create a partition is the size of the system’s
Logical Memory Block (LMB). The default LMB size varies according to the amount of
memory configured in the CEC as shown in Table 3-1.
Table 3-1 Configured CEC memory-to-default Logical Memory Block size
But in most cases, the actual minimum requirements and preferable capacities of the
supported operating systems are above 256 MB. Physical memory is assigned to partitions in
increments of Logical Memory Block.
The POWER Hypervisor provides the following types of virtual I/O adapters:
Virtual SCSI
Virtual Ethernet
Virtual Fibre Channel
Virtual (TTY) console
Configurable CEC memory Default Logical Memory Block
Greater than 8 GB up to 16 GB 64 MB
Greater than 16 GB up to 32 GB 128 MB
Greater than 32 GB 256 MB
104 IBM Power 720 and 740: Technical Overview and Introduction
3.2.1 Virtual SCSI
The POWER Hypervisor provides a virtual SCSI mechanism for virtualization of storage
devices. The storage virtualization is accomplished using two, paired, adapters: a virtual
SCSI server adapter and a virtual SCSI client adapter. A Virtual I/O Server partition or a IBM i
partition can define virtual SCSI server adapters, other partitions are client partitions. The
Virtual I/O server partition is a special logical partition, as described in 3.5.4, “Virtual I/O
Server” on page 119. The Virtual I/O Server software is available with the optional PowerVM
Edition features.
3.2.2 Virtual Ethernet
The POWER Hypervisor provides a virtual Ethernet switch function that allows partitions on
the same server to use a fast and secure communication without any need for physical
interconnection. The virtual Ethernet allows a transmission speed in the range of 1 to 3 Gbps.
depending on the MTU1
size and CPU entitlement. Virtual Ethernet support starts with AIX
Version 5.3, or appropriate level of Linux supporting Virtual Ethernet devices (see 3.5.9,
“Operating System support for PowerVM” on page 126). The virtual Ethernet is part of the
base system configuration.
Virtual Ethernet has the following major features:
The virtual Ethernet adapters can be used for both IPv4 and IPv6 communication and can
transmit packets with a size up to 65408 bytes. Therefore, the maximum MTU for the
corresponding interface can be up to 65394 (65390 if VLAN tagging is used).
The POWER Hypervisor presents itself to partitions as a virtual 802.1Q compliant switch.
The maximum number of VLANs is 4096. Virtual Ethernet adapters can be configured as
either untagged or tagged (following the IEEE 802.1Q VLAN standard).
A partition supports 256 virtual Ethernet adapters. Besides a default port VLAN ID, the
number of additional VLAN ID values that can be assigned per Virtual Ethernet adapter
is 20, which implies that each Virtual Ethernet adapter can be used to access 21 virtual
networks.
Each partition operating system detects the virtual local area network (VLAN) switch as an
Ethernet adapter without the physical link properties and asynchronous data transmit
operations.
Any virtual Ethernet can also have connectivity outside of the server if a layer-2 bridge to a
physical Ethernet adapter is set in one Virtual I/O server partition (see 3.5.4, “Virtual I/O
Server” on page 119 for more details about shared Ethernet). This is also known as Shared
Ethernet Adapter.
1 Maximum transmission unit
Note: Virtual Ethernet is based on the IEEE 802.1Q VLAN standard. No physical I/O
adapter is required when creating a VLAN connection between partitions, and no access to
an outside network is required.
Chapter 3. Virtualization 105
3.2.3 Virtual Fibre Channel
A virtual Fibre Channel adapter is a virtual adapter that provides client logical partitions with a
Fibre Channel connection to a storage area network through the Virtual I/O Server logical
partition. The Virtual I/O Server logical partition provides the connection between the virtual
Fibre Channel adapters on the Virtual I/O Server logical partition and the physical Fibre
Channel adapters on the managed system. Figure 3-1 depicts the connections between the
client partition virtual Fibre Channel adapters and the external storage. For additional
information, see 3.5.8, “NPIV” on page 126.
Figure 3-1 Connectivity between virtual Fibre Channels adapters and external SAN devices
3.2.4 Virtual (TTY) console
Each partition needs to have access to a system console. Tasks such as operating system
installation, network setup, and some problem analysis activities require a dedicated system
console. The POWER Hypervisor provides the virtual console using a virtual TTY or serial
adapter and a set of Hypervisor calls to operate on them. Virtual TTY does not require the
purchase of any additional features or software such as the PowerVM Edition features.
Depending on the system configuration, the operating system console can be provided by the
Hardware Management Console virtual TTY, IVM virtual TTY, or from a terminal emulator that
is connected to a system port.
Virtual I/O Server
Server virtual Fibre
Channel adapter
Server virtual Fibre
Channel adapter
Server virtual Fibre
Channel adapter
Physical Fibre
Channel adapter
Storage Area
Network
Physical
Storage 1
Physical
Storage 2
Physical
Storage 3
Client logical
Partition 1
Client virtual
Fibre Channel
adapter
Client logical
Partition 2
Client virtual
Fibre Channel
adapter
Client logical
Partition 3
Client virtual
Fibre Channel
adapter
Hypervisor
106 IBM Power 720 and 740: Technical Overview and Introduction
3.3 POWER processor modes
Although not a virtualization feature, strictly speaking, POWER modes are described here
because they have an impact on some virtualization features.
On any Power Systems server, partitions can be configured to run in various modes:
POWER6 compatibility mode:
This execution mode is compatible with Version 2.05 of the Power Instruction Set
Architecture (ISA).
http://www.power.org/resources/reading/PowerISA_V2.05.pdf
POWER6+ compatibility mode:
This mode is similar to the POWER6 compatibility mode, with eight additional Storage
Protection Keys.
POWER7 mode:
This is the native mode for POWER7 processors, implementing the v2.06 of the Power
Instruction Set Architecture.
http://www.power.org/resources/downloads/PowerISA_V2.06_PUBLIC.pdf
The selection of the mode is made on a per partition basis, from the HMC, by editing the
partition profile as presented in Figure 3-2.
Figure 3-2 Configuring partition profile compatibility mode from the HMC
Chapter 3. Virtualization 107
Table 3-2 lists the differences between these modes.
Table 3-2 Differences between POWER6 and POWER7 mode
3.4 Active Memory Expansion
Active Memory Expansion is an innovative POWER7 technology that allows the effective
maximum memory capacity to be much larger than the true physical memory maximum.
Compression and decompression of memory content can allow memory expansion up to
100%. This can allow a partition to do significantly more work or support more users with the
same physical amount of memory. Similarly, it can allow a server to run more partitions and
do more work for the same physical amount of memory.
Active Memory Expansion enablement is an optional hardware feature of POWER7
processor-based servers, that must be specified when creating the configuration in the
e-config tool:
IBM Power 720 #4793
IBM Power 740 #4794
Active Memory Expansion is available for partitions running AIX 6.1, Technology Level 4 with
SP2, or later.
POWER6 mode (and POWER6+) POWER7 mode Customer value
2-thread SMT 4-thread SMT Throughputperformance,processor
core utilization
VMX (Vector Multimedia Extension /
AltiVec)
VSX (Vector Scalar
Extension)
High performance computing
Affinity OFF by default 3-tier memory,
Micropartition Affinity
Improved system performance for
system images spanning sockets
and nodes.
Barrier Synchronization
Fixed 128-byte Array; Kernel
Extension Access
Enhanced Barrier
Synchronization
Variable Sized
Array; User
Shared Memory
Access
High performance computing
parallel programming
synchronization facility
64-core/128-thread Scaling 32-core /
128-thread
Scaling
64-core /
256-thread
Scaling
256-core /
1024-thread
Scaling
Performance and Scalability for
Large Scale-Up Single System
Image Workloads (for example,
OLTP, ERP scale-up, WPAR
consolidation)
EnergyScale CPU Idle EnergyScale CPU
Idle and Folding with
NAP and SLEEP
Improved Energy Efficiency
108 IBM Power 720 and 740: Technical Overview and Introduction
Active Memory Expansion uses CPU resource of a partition to compress/decompress the
memory contents of this same partition. The trade off of memory capacity for processor
cycles can be an excellent choice, but the degree of expansion varies based on how
compressible the memory content is, and it also depends on having adequate spare CPU
capacity available for this compression/decompression. Tests in IBM laboratories using
sample work loads showed excellent results for many workloads in terms of memory
expansion per additional CPU utilized. Other test workloads had more modest results.
Clients have a great deal of control over Active Memory Expansion usage. Each individual
AIX partition can turn on or turn off Active Memory Expansion. Control parameters set the
amount of expansion desired in each partition to help control the amount of CPU used by the
Active Memory Expansion function. An IPL is required for the specific partition that is turning
memory expansion on or off. After being turned on, there are monitoring capabilities in
standard AIX performance tools such as lparstat, vmstat, topas, and svmon.
Figure 3-3 represents the percentage of CPU used to compress memory for two partitions
with various profiles. The green curve corresponds to a partition that has spare processing
power capacity, while the blue curve corresponds to a partition constrained in processing
power.
Figure 3-3 CPU usage versus memory expansion effectiveness
Both cases shows that there is a knee-of-curve relationship for CPU resource required for
memory expansion:
Busy processor cores do not have resources to spare for expansion.
The more memory expansion is done, the more CPU resource is required.
The knee varies depending on how compressible memory contents are. This demonstrates
the need for a case by case study of whether memory expansion can provide a positive return
on investment.
To help you perform this study, a planning tool is included with AIX 6.1 Technology Level 4
allowing you to sample actual workloads and estimate both how expandable the partition's
memory is and how much CPU resource is needed. Any model Power System can run the
planning tool.
Figure 3-4 on page 109 shows an example of the output returned by this planning tool. The
tool outputs various real memory and CPU resource combinations to achieve the desired
effective memory and indicates one particular combination. In this example, the tool proposes
to allocate 58% of a processor core, to benefit from 45% extra memory capacity.
% CPU
utilization
for
expansion
Amount of memory expansion
1 = Plenty of spare
CPU resource available
2 = Constrained CPU
resource – already
running at significant
utilization
1
2
Very cost effective
Chapter 3. Virtualization 109
Figure 3-4 Output form Active Memory Expansion planning tool
When you have selected the value of the memory expansion factor you want to achieve, you
can use this value to configure the partition from the HMC, as shown in Figure 3-5.
Figure 3-5 Using the planning tool result to configure the partition
Active Memory Expansion Modeled Statistics:
-----------------------
Modeled Expanded Memory Size : 8.00 GB
Expansion True Memory Modeled Memory CPU Usage
Factor Modeled Size Gain Estimate
--------- -------------- ----------------- -----------
1.21 6.75 GB 1.25 GB [ 19%] 0.00
1.31 6.25 GB 1.75 GB [ 28%] 0.20
1.41 5.75 GB 2.25 GB [ 39%] 0.35
1.51 5.50 GB 2.50 GB[ 45%] 0.58
1.61 5.00 GB 3.00 GB [ 60%] 1.46
Active Memory Expansion Recommendation:
---------------------
The recommended AME configuration for this workload is to configure
the LPAR with a memory size of 5.50 GB and to configure a memory
expansion factor of 1.51. This will result in a memory expansion of
45% from the LPAR's current memory size. With this configuration,
the estimated CPU usage due to Active Memory Expansion is
approximately 0.58 physical processors, and the estimated overall
peak CPU resource required for the LPAR is 3.72 physical processors.
5.5 true
8.0 max
5.5 true
8.0 max
Active Memory Expansion Modeled Statistics:
-----------------------
Modeled Expanded Memory Size : 8.00 GB
Expansion True Memory Modeled Memory CPU Usage
Factor Modeled Size Gain Estimate
--------- -------------- ----------------- -----------
1.21 6.75 GB 1.25 GB [ 19%] 0.00
1.31 6.25 GB 1.75 GB [ 28%] 0.20
1.41 5.75 GB 2.25 GB [ 39%] 0.35
1.51 5.50 GB 2.50 GB[ 45%] 0.58
1.61 5.00 GB 3.00 GB [ 60%] 1.46
Active Memory Expansion Recommendation:
---------------------
The recommended AME configuration for this workload is to
configure the LPAR with a memory size of 5.50 GB and to configure
a memory expansion factor of 1.51. This will result in a memory
expansion of 45% from the LPAR's current memory size. With this
configuration, the estimated CPU usage due to Active Memory
Expansion is approximately 0.58 physical processors, and the
estimated overall peak CPU resource required for the LPAR is 3.72
physical processors.
Sample output
110 IBM Power 720 and 740: Technical Overview and Introduction
On the HMC menu describing the partition, select the Active Memory Expansion check box
and enter true and max memory, as well as the memory expansion factor. To turn off
expansion, you just have to unselect the check box. In both cases, a reboot of the partition is
needed to activate the change.
In addition, a one-time, 60-day trial of Active Memory Expansion is available to provide more
exact memory expansion and CPU measurements. The trial can be requested using the
Capacity on Demand web page:
http://www.ibm.com/systems/power/hardware/cod/
Active Memory Expansion can be ordered with the initial order of the server or as an MES
order. A software key is provided when the enablement feature is ordered that is applied to
the server. A reboot is not required to enable the physical server. The key is specific to an
individual server and is permanent. It cannot be moved to another server. This feature is
ordered per server, independently of the number of partitions using memory expansion.
It is possible to view if the Active Memory Expansion feature has been activated on a server
from the HMC, as presented in Figure 3-6:
Figure 3-6 Server capabilities listed from the HMC
Note: In order to move an LPAR using Active Memory Expansion through Live Partition
Mobility to another system, the target system must support AME. That means the target
system must have AME activated through the software key. If the target system does not
have AME activated, the mobility operation will fail during the pre-mobility check phase,
and an appropriate error message will be displayed to the user.
Chapter 3. Virtualization 111
For detailed information regarding Active Memory Expansion, you can download the
document Active Memory Expansion: Overview and Usage Guide from:
http://www.ibm.com/common/ssi/fcgi-bin/ssialias?infotype=SA&subtype=WH&appname=STG
E_PO_PO_USEN&htmlfid=POW03037USEN&attachment=POW03037USEN.PDF
3.5 PowerVM
PowerVM is the industry-leading virtualization solution for AIX, IBM i, and Linux environments
on IBM POWER processor-based systems. PowerVM offers a secure virtualization
environment, built on the advanced RAS features and leadership performance of the Power
Systems platform. PowerVM features leading technologies such as Logical Partitioning, IBM
Micro-Partitioning™, Power Hypervisor, Virtual I/O Server, PowerVM Lx86, PowerVM Live
Partition Mobility, and PowerVM Active Memory Sharing. As with the previous Advanced
Power Virtualization solution, PowerVM is a combination of hardware enablement and
value-added software. The licensed features of each of the three editions of PowerVM are
discussed in 3.5.1, “PowerVM editions” on page 111.
3.5.1 PowerVM editions
This section provides information about the virtualization capabilities of the PowerVM. There
are three versions of PowerVM, suited for various purposes:
PowerVM Express Edition:
PowerVM Express Edition is designed for customers looking for an introduction to more
advanced virtualization features at a highly affordable price.
PowerVM Standard Edition:
PowerVM Standard Edition provides the most complete virtualization functionality for AIX,
IBM i, and Linux operating systems in the industry. PowerVM Standard Edition is
supported on all POWER processor-based servers and includes features designed to
allow businesses to increase system utilization.
PowerVM Enterprise Edition:
PowerVM Enterprise Edition includes all the features of PowerVM Standard Edition plus
two new industry-leading capabilities called Active Memory Sharing and Live Partition
Mobility.
Table 3-3 lists the codes of PowerVM editions that are available on the Power 720 and
Power 740 servers.
Table 3-3 Availability of PowerVM editions on the Power 720 and Power 740
PowerVM Editions Express Standard Enterprise
IBM Power 720 #5225 #5227 #5228
IBM Power 740 #5225 #5227 #5228
112 IBM Power 720 and 740: Technical Overview and Introduction
It is possible to upgrade from the Express Edition to the Standard or Enterprise Edition, and
from Standard to Enterprise Editions. Table 3-4 outlines the functional elements of the three
PowerVM editions.
Table 3-4 PowerVM capabilities
3.5.2 Logical partitions
Logical partitions (LPARs) and virtualization increase utilization of system resources and add
a new level of configuration possibilities. This section provides details and configuration
specifications for these topics.
Dynamic logical partitioning
Logical partitioning (LPAR) was introduced with the IBM POWER4™ processor-based
product line and the IBM AIX Version 5.1 operating system. This technology offered the
capability to divide a pSeries system into separate logical systems, allowing each LPAR to run
an operating environment on dedicated attached devices, such as processors, memory, and
I/O components.
Later, dynamic logical partitioning increased the flexibility, allowing selected system
resources, such as processors, memory, and I/O components, to be added and deleted from
logical partitions while they are executing. IBM AIX Version 5.2, with all the necessary
enhancements to enable dynamic LPARs, was introduced in 2002. The ability to reconfigure
dynamic LPARs encourages system administrators to dynamically redefine all available
system resources to reach the optimum capacity for each defined dynamic LPAR.
Micro-Partitioning
Micro-Partitioning technology allows you to allocate fractions of processors to a logical
partition. This technology was introduced with POWER5 processor-based systems. A logical
partition using fractions of processors is also known as a Shared Processor Partition or
Micro-Partition. Micro-Partitions run over a set of processors called a Shared Processor Pool.
Virtual processors are used to let the operating system manage the fractions of processing
power assigned to the logical partition. From an operating system perspective, a virtual
processor cannot be distinguished from a physical processor, unless the operating system
has been enhanced to be made aware of the difference. Physical processors are abstracted
into virtual processors that are available to partitions. The meaning of the term physical
processor in this section is a processor core. For example, in a 2-core server there are two
physical processors.
PowerVM Editions Express Standard Enterprise
Micro-partitions Yes Yes Yes
Maximum LPARs 1 or 2 per server 10/core 10/core
Management IVM IVM or HMC IVM or HMC
Virtual IO Server Yes Yes Yes
NPIV Yes Yes Yes
Multiple Shared Processor Pool No Yes Yes
Live Partition Mobility No No Yes
Active Memory Sharing No No Yes
Chapter 3. Virtualization 113
When defining a shared processor partition, various options have to be defined:
The minimum, desired, and maximum processing units. Processing units are defined as
processing power, or the fraction of time that the partition is dispatched on physical
processors. Processing units define the capacity entitlement of the partition.
The shared processor pool. Pick one from the list with the names of each configured
shared processor pool. This list also displays the pool ID of each configured shared
processor pool in parentheses. If the name of the desired shared processor pool is not
available here, you must first configure the desired shared processor pool using the
Shared Processor Pool Management window. Shared processor partitions use the default
shared processor pool called DefaultPool by default.
Whether the partition will be able or not to access extra processing power to “fill up” its
virtual processors above its capacity entitlement. You select either to cap or uncap your
partition. If there is spare processing power available in the shared processor pool or if
other partitions are not using their entitlement, an uncapped partition can use additional
processing units if its entitlement is not enough to satisfy its application processing
demand.
The weight (preference) in the case of an uncapped partition.
The minimum, desired, and maximum number of virtual processors.
The POWER Hypervisor calculates partitions’ processing power based on minimum, desired,
and maximum values, processing mode, and also based on other active partitions’
requirements. The actual entitlement is never smaller than the processing units desired value
but can exceed that value in the case of an uncapped partition and up to the number of virtual
processors allocated.
A partition can be defined with a processor capacity as small as 0.10 processing units. This
represents 1/10th of a physical processor. Each physical processor can be shared by up to
ten shared processor partitions, and the partition’s entitlement can be incremented
fractionally by as little as 1/100th of the processor. The shared processor partitions are
dispatched and time-sliced on the physical processors under control of the POWER
Hypervisor. The shared processor partitions are created and managed by the HMC or
Integrated Virtualization Management.
The IBM Power 720 system can be configured with up to eight cores, and the IBM Power 740
up to 16 cores. These systems can support LPARs as follows:
Up to 80 LPARs on a Power 720
Up to 160 LPARs on a Power 740
Here we provide additional information about virtual processors:
A virtual processor can be either running (dispatched) on a physical processor or standby
waiting for a physical processor to became available.
Virtual processors do not introduce any additional abstraction level; they really are only a
dispatch entity. When running on a physical processor, virtual processors run at the same
speed as the physical processor.
Each partition’s profile defines CPU entitlement that determines how much processing
power any given partition must receive. The total sum of CPU entitlement of all partitions
cannot exceed the number of available physical processors in a shared processor pool.
The number of virtual processors can be changed dynamically through a dynamic LPAR
operation.
Important: The maximums stated are supported by the hardware, but the practical limits
depend on the application workload demands.
114 IBM Power 720 and 740: Technical Overview and Introduction
Processing Mode
When you create a logical partition, you can assign entire processors for dedicated use, or
you can assign partial processor units from a shared processor pool. This setting will define
the processing mode of the logical partition. Figure 3-7 shows a diagram of the concepts
discussed in this section.
Figure 3-7 Logical partitioning concepts
Dedicated mode
In dedicated mode, physical processors are assigned as a whole to partitions. The
simultaneous multithreading feature in the POWER7 processor core allows the core to
execute instructions from two or four independent software threads simultaneously. To
support this feature we use the concept of logical processors. The operating system
(AIX, IBM i or Linux) sees one physical processor as two or four logical processors if the
simultaneous multithreading feature is on. It can be turned off and on dynamically while the
operating system is executing (for AIX, use the smtctl command). If simultaneous
multithreading is off, then each physical processor is presented as one logical processor and
thus only one thread.
Shared dedicated mode
On POWER7 processor technology based servers, you can configure dedicated partitions to
become processor donors for idle processors they own, allowing for the donation of spare
CPU cycles from dedicated processor partitions to a Shared Processor Pool. The dedicated
partition maintains absolute priority for dedicated CPU cycles. Enabling this feature can help
to increase system utilization, without compromising the computing power for critical
workloads in a dedicated processor.
Shared mode
In shared mode, logical partitions use virtual processors to access fractions of physical
processors. Shared partitions can define any number of virtual processors (the maximum
number is 10 times the number of processing units assigned to the partition). From the
POWER Hypervisor point of view, virtual processors represent dispatching objects. The
POWER Hypervisor dispatches virtual processors to physical processors according to the
Set of micro-partitions
Dedicated processor
partitions
AIXV5.3
AIXV6.1
lp lplp lp lp lp
AIXV6.1
1.5PrU
AIXV5.3
0.5PrU
lp lplp lplp lp
vp vp vp
Shared-Processor Pool 0
Set of micro-partitions
AIXV6.1
1.5PrU
Linux
0.5PrU
lp lplp lplp lp
vp vp vp
Shared-Processor Pool 1
POWER Hypervisor
Dedicated Processors Physical Shared-Processor Pool
8-core SMP System
KEY:
vp Virtual Processor
lp Logical Processor
PrU Processing Units
Chapter 3. Virtualization 115
partition’s processing units entitlement. One Processing Unit represents one physical
processor’s processing capacity. At the end of the POWER Hypervisor’s dispatch cycle
(10 ms), all partitions must receive total CPU time equal to their processing units entitlement.
The logical processors are defined on top of virtual processors. So, even with a virtual
processor, the concept of a logical processor exists and the number of logical processors
depends on whether the simultaneous multithreading is turned on or off.
3.5.3 Multiple Shared-Processor Pools
Multiple Shared-Processor Pools (MSPPs) is a capability supported on POWER7 and
POWER6 processor-based servers. This capability allows a system administrator to create a
set of micro-partitions with the purpose of controlling the processor capacity that can be
consumed from the physical shared-processor pool.
To implement MSPPs, there is a set of underlying techniques and technologies. An overview
of the architecture of Multiple Shared-Processor Pools can be seen in Figure 3-8.
Figure 3-8 Overview of the architecture of Multiple Shared-Processor Pools
Micro-partitions are created and then identified as members of either the default
Shared-Processor Pool0 or a user-defined Shared-Processor Pooln. The virtual processors
that exist within the set of micro-partitions are monitored by the POWER Hypervisor and
processor capacity is managed according to user-defined attributes.
If the Power Systems server is under heavy load, each micro-partition within a
Shared-Processor Pool is guaranteed its processor entitlement plus any capacity that it can
be allocated from the Reserved Pool Capacity if the micro-partition is uncapped.
Physical Shared-Processor Pool
Shared-Processor Pool0
Set micro-partitions
AIX V6.1
EC 0.8
vp2
Linux
EC 0.5
vp3
vp4
AIX V5.3
EC 1.6
vp0
vp1
Shared-Processor Pool1
Set micro-partitions
AIX V6.1
EC 1.6
vp5
vp6
vp7
AIX V6.1
EC 0.8
vp8
Linux
EC 0.5
vp9
vp10
POWER Hypervisor
p0 p7p4 p5 p6p2 p3p1 KEY:
EC Entitled Capacity
p Physical Processor
vp Virtual Processor
SPPn Shared-Processor Pooln
Unused capacity in SPP1 is
redistributed to uncapped
micro partitions with SPP1
Unused capacity in SPP0 is
redistributed to uncapped
micro partitions with SPP0
116 IBM Power 720 and 740: Technical Overview and Introduction
If certain micro-partitions in a Shared-Processor Pool do not use their capacity entitlement,
the unused capacity is ceded and other uncapped micro-partitions within the same
Shared-Processor Pool are allocated the additional capacity according to their uncapped
weighting. In this way, the Entitled Pool Capacity of a Shared-Processor Pool is distributed to
the set of micro-partitions within that Shared-Processor Pool.
All Power Systems servers that support the Multiple Shared-Processor Pools capability will
have a minimum of one (the default) Shared-Processor Pool and up to a maximum of 64
Shared-Processor Pools.
Default Shared-Processor Pool (SPP0)
On any Power Systems server supporting Multiple Shared-Processor Pools, a default
Shared-Processor Pool is always automatically defined. The default Shared-Processor Pool
has a pool identifier of zero (SPP-ID = 0) and can also be referred to as SPP0. The default
Shared-Processor Pool has the same attributes as a user-defined Shared-Processor Pool
except that these attributes are not directly under the control of the system administrator;
they have fixed values (Table 3-5).
Table 3-5 Attribute values for the default Shared-Processor Pool (SPP0)
Creating Multiple Shared-Processor Pools
The default Shared-Processor Pool (SPP0) is automatically activated by the system and is
always present.
All other Shared-Processor Pools exist, but by default, are inactive. By changing the
Maximum Pool Capacity of a Shared-Processor Pool to a value greater than zero, it becomes
active and can accept micro-partitions (either transferred from SPP0 or newly created).
Levels of processor capacity resolution
There are two levels of processor capacity resolution implemented by the POWER Hypervisor
and Multiple Shared-Processor Pools:
Level0 The first level, Level0, is the resolution of capacity within the same
Shared-Processor Pool. Unused processor cycles from within a
Shared-Processor Pool are harvested and then redistributed to any eligible
micro-partition within the same Shared-Processor Pool.
Level1 When all Level0 capacity has been resolved within the Multiple Shared-Processor
Pools, the POWER Hypervisor harvests unused processor cycles and
redistributes them to eligible micro-partitions regardless of the Multiple
Shared-Processor Pools structure. This is the second level of processor capacity
resolution.
SPP0 attribute Value
Shared-Processor Pool ID 0
Maximum Pool Capacity The value is equal to the capacity in the physical
shared-processor pool.
Reserved Pool Capacity 0
Entitled Pool Capacity Sum (total) of the entitled capacities of the
micro-partitions in the default Shared-Processor
Pool.
Chapter 3. Virtualization 117
You can see the two levels of unused capacity redistribution implemented by the POWER
Hypervisor in Figure 3-9.
Figure 3-9 The two levels of unused capacity redistribution
Capacity allocation above the Entitled Pool Capacity (Level1)
The POWER Hypervisor initially manages the Entitled Pool Capacity at the Shared-Processor
Pool level. This is where unused processor capacity within a Shared-Processor Pool is
harvested and then redistributed to uncapped micro-partitions within the same
Shared-Processor Pool. This level of processor capacity management is sometimes referred
to as Level0 capacity resolution.
At a higher level, the POWER Hypervisor harvests unused processor capacity from the
Multiple Shared-Processor Pools that do not consume all of their Entitled Pool Capacity.
If a particular Shared-Processor Pool is heavily loaded and some of the uncapped
micro-partitions within it require additional processor capacity (above the Entitled Pool
Capacity) then the POWER Hypervisor redistributes some of the extra capacity to the
uncapped micro-partitions. This level of processor capacity management is sometimes
referred to as Level1 capacity resolution.
To redistribute unused processor capacity to uncapped micro-partitions in Multiple
Shared-Processor Pools above the Entitled Pool Capacity, the POWER Hypervisor uses a
higher level of redistribution, Level1.
POWER Hypervisor
Physical Shared-Processor Pool
SPP0
Micro-partition0
Micro-partition1
Micro-partition2
Micro-partition3
SPP1 SPP2 SPPn
Micro-partitionn
Level1 Capacity
Resolution
SPP0 Capacity
Resolution
SPP1 Capacity
Resolution
SPP2Capacity
Resolution
SPP3Capacity
Resolution
p0 p1 p2 p3 p4 p5
Level0 Capacity Resolution
Resolution of the Entitled Pool Capacity
within the same Shared-Processor Pool
Level0
Capacity
Resolution
Level1 Capacity Resolution
POWER Hypervisor harvests unused
processor capacity from Shared-Processor
Pools and redistributes it across all
uncapped micro-partitions regardless of the
Shared-Processor Pool structure
118 IBM Power 720 and 740: Technical Overview and Introduction
Where there is unused processor capacity in underutilized Shared-Processor Pools, the
micro-partitions within the Shared-Processor Pools cede the capacity to the POWER
Hypervisor.
In busy Shared-Processor Pools where the micro-partitions have used all of the Entitled Pool
Capacity, the POWER Hypervisor will allocate additional cycles to micro-partitions under the
following circumstances:
The Maximum Pool Capacity of the Shared-Processor Pool hosting the micro-partition has
not been met.
(and) The micro-partition is uncapped.
(and) The micro-partition has enough virtual-processors to take advantage of the
additional capacity.
Under such circumstances, the POWER Hypervisor allocates additional processor capacity to
micro-partitions on the basis of their uncapped weights independent of the Shared-Processor
Pool hosting the micro-partitions. This can be referred to as Level1 capacity resolution.
Consequently, when allocating additional processor capacity in excess of the Entitled Pool
Capacity of the Shared-Processor Pools, the POWER Hypervisor takes the uncapped
weights of all micro-partitions in the system into account, regardless of the Multiple
Shared-Processor Pools structure.
Dynamic adjustment of Maximum Pool Capacity
The Maximum Pool Capacity of a Shared-Processor Pool, other than the default
Shared-Processor Pool0, can be adjusted dynamically from the HMC using either the
graphical or CLI interface.
Dynamic adjustment of Reserve Pool Capacity
The Reserved Pool Capacity of a Shared-Processor Pool, other than the default
Shared-Processor Pool0, can be adjusted dynamically from the HMC using either the
graphical or CLI interface.
Dynamic movement between Shared-Processor Pools
A micro-partition can be moved dynamically from one Shared-Processor Pool to another
using the HMC using either the graphical or CLI interface. Because the Entitled Pool Capacity
is partly made up of the sum of the entitled capacities of the micro-partitions, removing a
micro-partition from a Shared-Processor Pool will reduce the Entitled Pool Capacity for that
Shared-Processor Pool. Similarly, the Entitled Pool Capacity of the Shared-Processor Pool
that the micro-partition joins will increase.
Deleting a Shared-Processor Pool
Shared-Processor Pools cannot be deleted from the system, but they can be deactivated by
setting the Maximum Pool Capacity and the Reserved Pool Capacity to zero. By doing so, the
Shared-Processor Pool will still exist but will not be active. You can use the HMC interface to
deactivate a Shared-Processor Pool. Be aware that a Shared-Processor Pool cannot be
deactivated unless all micro-partitions hosted by the Shared-Processor Pool have been
removed.
Important: For Level1 capacity resolution, when allocating additional processor capacity in
excess of the Entitled Pool Capacity of the Shared-Processor Pool, the POWER
Hypervisor takes into account the uncapped weights of all micro-partitions in the system,
regardless of the Multiple Shared-Processor Pool structure.
Chapter 3. Virtualization 119
Live Partition Mobility and Multiple Shared-Processor Pools
A micro-partition can leave a Shared-Processor Pool due to PowerVM Live Partition Mobility.
Similarly, a micro-partition can join a Shared-Processor Pool in the same way. When
performing PowerVM Live Partition Mobility, you are given the opportunity to designate a
destination Shared-Processor Pool on the target server to receive and host the migrating
micro-partition.
Because several simultaneous micro-partition migrations are supported by PowerVM Live
Partition Mobility, it is conceivable to migrate the entire Shared-Processor Pool from one
server to another.
3.5.4 Virtual I/O Server
The Virtual I/O Server is part of all PowerVM Editions. It is a special purpose partition that
allows the sharing of physical resources between logical partitions to allow more efficient
utilization (for example consolidation). In this case the Virtual I/O Server owns the physical
resources (SCSI, Fibre Channel, network adapters, and optical devices) and allows client
partitions to share access to them, thus minimizing the number of physical adapters in the
system. The Virtual I/O Server eliminates the requirement that every partition owns a
dedicated network adapter, disk adapter, and disk drive. The Virtual I/O Server supports
OpenSSH for secure remote logins. It also provides a firewall for limiting access by ports,
network services and IP addresses. Figure 3-10 shows an overview of a Virtual I/O Server
configuration.
Figure 3-10 Architectural view of the Virtual I/O Server
Because the Virtual I/O server is an operating system-based appliance server, redundancy
for physical devices attached to the Virtual I/O Server can be provided by using capabilities
such as Multipath I/O and IEEE 802.3ad Link Aggregation.
Installation of the Virtual I/O Server partition is performed from a special system backup DVD
that is provided to clients that order any PowerVM edition. This dedicated software is only for
the Virtual I/O Server (and IVM in case it is used) and is only supported in special Virtual I/O
Server partitions. Three major virtual devices are supported by the Virtual I/O Server: a
Shared Ethernet Adapter, Virtual SCSI and Virtual Fibre Channel adapter. The Virtual Fibre
Channel adapter is used with the NPIV feature, described in 3.5.8, “NPIV” on page 126.
Virtual I/O Server Virtual I/O Client 1Hypervisor
Virtual I/O Client 2
Physical Ethernet
Adapter
Shared Ethernet
Adapter
External
Network
Physical Disk
Adapter
Physical Disk
Physical Disk
Virtual SCSI
Adapter
Virtual Ethernet
Adapter
Virtual Ethernet
Adapter
Virtual SCSI
Adapter
Virtual SCSI
Adapter
Virtual Ethernet
Adapter
120 IBM Power 720 and 740: Technical Overview and Introduction
Shared Ethernet Adapter
A Shared Ethernet Adapter (SEA) can be used to connect a physical Ethernet network to a
virtual Ethernet network. The Shared Ethernet Adapter provides this access by connecting
the internal Hypervisor VLANs with the VLANs on the external switches. Because the Shared
Ethernet Adapter processes packets at layer 2, the original MAC address and VLAN tags of
the packet are visible to other systems on the physical network. IEEE 802.1 VLAN tagging is
supported.
The Shared Ethernet Adapter also provides the ability for several client partitions to share one
physical adapter. Using an SEA, you can connect internal and external VLANs using a
physical adapter. The Shared Ethernet Adapter service can only be hosted in the Virtual I/O
Server, not in a general purpose AIX, IBM i, or Linux partition, and acts as a layer-2 network
bridge to securely transport network traffic between virtual Ethernet networks (internal) and
one or more (EtherChannel) physical network adapters (external). These virtual Ethernet
network adapters are defined by the POWER Hypervisor on the Virtual I/O Server
Figure 3-11 shows a configuration example of an SEA with one physical and two virtual
Ethernet adapters. An SEA can include up to 16 virtual Ethernet adapters on the Virtual I/O
Server that share the same physical access.
Figure 3-11 Architectural view of a Shared Ethernet Adapter
Tip: A Linux partition can provide bridging function as well, by using the brctl command.
Ethernet
Switch
Hypervisor
VIOS
Default
Client 1 Client 2 Client 3
VID=2
(PVID=99)
PVID=1
PVID=2
VLAN=2
VLAN=1
(PVID=1)VLAN=2
PVID=1
PVID=1
External
Network
en3
(if.)
ent3
(sea)
ent1
(virt.)
ent2
(virt.)
ent0
(phy.)
en0
(if.)
ent0
(virt.)
en0
(if.)
ent0
(virt.)
en0
(if.)
ent0
(virt.)
Chapter 3. Virtualization 121
A single SEA setup can have up to 16 Virtual Ethernet trunk adapters, and each virtual
Ethernet trunk adapter can support up to 20 VLAN networks. Therefore, it is possible for a
single physical Ethernet to be shared between 320 internal VLANs. The number of shared
Ethernet adapters that can be set up in a Virtual I/O server partition is limited only by the
resource availability, because there are no configuration limits.
Unicast, broadcast, and multicast is supported, so protocols that rely on broadcast or
multicast, such as Address Resolution Protocol (ARP), Dynamic Host Configuration Protocol
(DHCP), Boot Protocol (BOOTP), and Neighbor Discovery Protocol (NDP) can work across
an SEA.
Virtual SCSI
Virtual SCSI is used to refer to a virtualized implementation of the SCSI protocol. Virtual SCSI
is based on a client/server relationship. The Virtual I/O Server logical partition owns the
physical resources and acts as server or, in SCSI terms, target device. The client logical
partitions access the virtual SCSI backing storage devices provided by the Virtual I/O Server
as clients.
The virtual I/O adapters (a virtual SCSI server adapter and a virtual SCSI client adapter) are
configured using an HMC or through the Integrated Virtualization Manager. The virtual SCSI
server (target) adapter is responsible for executing any SCSI commands it receives. It is
owned by the Virtual I/O Server partition. The virtual SCSI client adapter allows a client
partition to access physical SCSI and SAN attached devices and LUNs that are assigned to
the client partition. The provisioning of virtual disk resources is provided by the Virtual I/O
Server.
Physical disks presented to the Virtual/O Server can be exported and assigned to a client
partition in a number of ways:
The entire disk is presented to the client partition.
The disk is divided into several logical volumes, which can be presented to a single client
or multiple clients.
As of Virtual I/O Server 1.5 or later, files can be created on these disks and file backed
storage devices can be created.
The logical volumes or files can be assigned to various partitions. Therefore, virtual SCSI
enables sharing of adapters as well as disk devices.
Figure 3-12 on page 122 shows an example where one physical disk is divided into two
logical volumes by the Virtual I/O Server. Each of the two client partitions is assigned one
logical volume, which is then accessed through a virtual I/O adapter (VSCSI Client Adapter).
Inside the partition, the disk is seen as a normal hdisk.
Note: A Shared Ethernet Adapter does not need to have an IP address configured to be
able to perform the Ethernet bridging functionality. It is very convenient to configure IP on
the Virtual I/O Server, because the Virtual I/O Server can then be reached by TCP/IP, for
example, to perform dynamic LPAR operations or to enable remote login. These operations
can be done either by configuring an IP address directly on the SEA device, or on an
additional virtual Ethernet adapter in the Virtual I/O Server, thus leaving the SEA without
the IP address, and allowing for maintenance on the SEA without losing IP connectivity in
case SEA failover is configured.
122 IBM Power 720 and 740: Technical Overview and Introduction
Figure 3-12 Architectural view of virtual SCSI
At the time of writing, virtual SCSI supports Fibre Channel, parallel SCSI, iSCSI, SAS, SCSI
RAID devices and optical devices, including DVD-RAM and DVD-ROM. Other protocols such
as SSA and tape devices are not supported.
For more information about the specific storage devices supported for Virtual I/O Server, see:
http://www14.software.ibm.com/webapp/set2/sas/f/vios/documentation/datasheet.html
Virtual I/O Server functions
Virtual I/O Server includes a number of features, including monitoring solutions:
Support for Live Partition Mobility on POWER6 and POWER7 processor-based systems
with the PowerVM Enterprise Edition. More information about Live Partition Mobility can
be found in 3.5.6, “PowerVM Live Partition Mobility” on page 123.
Support for virtual SCSI devices backed by a file. These are then accessed as standard
SCSI-compliant LUNs.
Support for virtual Fibre Channel devices used with the NPIV feature.
Virtual I/O Server Expansion Pack with additional security functions such as Kerberos
(Network Authentication Service for users and Client and Server Applications), SNMP v3
(Simple Network Management Protocol) and LDAP (Lightweight Directory Access
Protocol client functionality).
System Planning Tool (SPT) and Workload Estimator are designed to ease the
deployment of a virtualized infrastructure. More information about the System Planning
Tool is provided in 3.6, “System Planning Tool” on page 128.
IBM Systems Director and a number of pre-installed IBM Tivoli® agents are included,
such as Tivoli Identity Manager (TIM), in order to allow easy integration into an existing
Tivoli Systems Management infrastructure, and Tivoli Application Dependency Discovery
Manager (ADDM), which creates and maintains automatically application infrastructure
maps, including dependencies, change histories, and deep configuration values.
vSCSI eRAS is also available.
Client Partition 1I/O Server Partition
LVM
Client Partition 2
Logical
Volume 1
Logical
Volume 2
Hdisk Hdisk
POWER Hypervisor
Physical
Disk
(SCSI, FC)
Physical Adapter
vSCSI
Server
Adapter
vSCSI
Server
Adapter
vSCSI
Client
Adapter
vSCSI
Client
Adapter
Chapter 3. Virtualization 123
Additional Command Line Interface (CLI) statistics in svmon, vmstat, fcstat, and topas
Monitoring solutions to help manage and monitor the Virtual I/O Server and shared
resources. New commands and views provide additional metrics for memory, paging,
processes, Fibre Channel HBA statistics, and virtualization.
For more information on the Virtual I/O Server and its implementation, see PowerVM
Virtualization on IBM System p: Introduction and Configuration Fourth Edition, SG24-7940.
3.5.5 PowerVM Lx86
PowerVM Lx86 supports the installation and running of most 32-bit x86 Linux applications on
any POWER5, POWER5+, POWER6, POWER6+, and POWER7 processor-based server, or
IBM Power Architecture technology-based blade servers. PowerVM Lx86 creates a virtual
x86 environment, within which the Linux on Intel® applications can run. Currently, a virtual
PowerVM Lx86 environment supports SUSE Linux or Red Hat Linux x86 distributions. The
translator and the virtual environment run strictly within user space. No modifications to the
POWER kernel are required. PowerVM Lx86 does not run the x86 kernel on the POWER
system and is not a virtual machine. Instead, x86 applications are encapsulated so that the
operating environment appears to be Linux on x86, even though the underlying system is a
Linux on POWER system.
PowerVM Lx86 release 1.4 supports all POWER7 processors-based servers.
For more information about PowerVM Lx86, see the following website:
http://www14.software.ibm.com/webapp/set2/sas/f/lx86/related/home.html
3.5.6 PowerVM Live Partition Mobility
PowerVM Live Partition Mobility allows you to move a running logical partition, including its
operating system and running applications, from one system to another without any shutdown
or without disrupting the operation of that logical partition. Inactive partition mobility allows
you to move a powered off logical partition from one system to another.
Partition mobility provides systems management flexibility and improves system availability:
Avoid planned outages for hardware or firmware maintenance by moving logical partitions
to another server and then performing the maintenance. Live Partition Mobility can help
lead to zero downtime maintenance because you can use it to work around scheduled
maintenance activities.
Avoid downtime for a server upgrade by moving logical partitions to another server and
then performing the upgrade. This allows your end users to continue their work without
disruption.
Perform preventive failure management: If a server indicates a potential failure, you can
move its logical partitions to another server before the failure occurs. Partition mobility can
help avoid unplanned downtime.
Optimize server workloads:
– You can consolidate workloads running on several small, under-utilized servers onto a
single large server.
Note: RHEL5 only supports POWER7 processor-based servers in POWER6 Compatibility
Mode. Customers will need to use SLES11 to take full advantage of the POWER7
technology.
124 IBM Power 720 and 740: Technical Overview and Introduction
– Deconsolidation: You can move workloads from server to server to optimize resource
use and workload performance within your computing environment. With active
partition mobility, you can manage workloads with minimal downtime.
Use Live Partition Mobility for a migration from POWER6 to POWER7 processor-based
servers without any downtime of your applications.
Mobile partition’s operating system requirements
The operating system running in the mobile partition must be AIX or Linux. The Virtual I/O
Server partition itself cannot be migrated. All versions of AIX and Linux supported on the IBM
POWER7 processor-based servers also support partition mobility.
Source and destination system requirements
The source partition must be one that only has virtual devices. If there are any physical
devices in its allocation, they must be removed before the validation or migration is initiated.
An NPIV device is considered virtual and is compatible with partition migration.
The POWER Hypervisor must support the Partition Mobility functionality also called migration
process. POWER6 and POWER7 processor-based Hypervisors have this capability and
firmware must be at firmware level eFW3.2 or later. All POWER7 processor-based
hypervisors support Partition Mobility. Source and destination systems can have various
firmware levels, but they must be compatible with each other.
It is possible to migrate partitions back and forth between POWER6 and POWER7
processor-based servers. Partition Mobility leverages the POWER6 Compatibility Modes
provided by POWER7 processor-based servers. On the POWER7 processor technology
based server, the migrated partition is then executing in POWER6 or POWER6+
Compatibility Mode.
If you want to move an active logical partition from a POWER6 processor-based server to a
POWER7 processor-based server so that the logical partition can take advantage of the
additional capabilities available with the POWER7 processor, you can perform these steps:
1. You set the percolating preferred processor compatibility mode to the default mode. When
you activate the logical partition on the POWER6 processor-based server, it runs in the
POWER6 mode.
2. You move the logical partition to the POWER7 processor-based server. Both the current
and preferred modes remain unchanged for the logical partition until you restart the logical
partition.
3. You restart the logical partition on the POWER7 processor-based server. The hypervisor
evaluates the configuration. Because the preferred mode is set to default and the logical
partition now runs on a POWER7 processor-based server, the highest mode available is
the POWER7 mode. The POWER hypervisor determines that the most fully featured
mode supported by the operating environment installed in the logical partition is the
POWER7 mode and changes the current mode of the logical partition to the POWER7
mode.
At this point, the current processor compatibility mode of the logical partition is the POWER7
mode and the logical partition runs on the POWER7 processor-based server.
Tip: For an exhaustive presentation of the supported migrations, see the “Migration
combinations of processor compatibility modes for active Partition Mobility” web page:
http://publib.boulder.ibm.com/infocenter/powersys/v3r1m5/topic/p7hc3/iphc3pcmco
mbosact.htm
Chapter 3. Virtualization 125
The Virtual I/O Server on the source system provides access to the client resources and must
be identified as a Mover Service Partition (MSP). The Virtual Asynchronous Services
Interface (VASI) device allows the mover service partition to communicate with the POWER
hypervisor; it is created and managed automatically by the HMC and will be configured on
both the source and destination Virtual I/O Servers designated as the mover service
partitions for the mobile partition to participate in active mobility. Other requirements include a
similar Time of Day on each server, systems cannot be running on battery power, shared
storage (turn off SCSI reservation at any external hdisk using reserve_policy=no_reserve),
and all logical partitions must be on the same open network with RMC established to the
HMC.
The HMC is used to configure, validate, and orchestrate. You will use the HMC to configure
the Virtual I/O Server as an MSP and to configure the VASI device. An HMC wizard validates
your configuration and identifies issues that will cause the migration to fail. During the
migration, the HMC controls all phases of the process.
Improved Live Partition Mobility benefits
The possibility to move partitions between POWER6 and POWER7 processor-based servers
greatly facilitates the deployment of POWER7 processor technology based servers:
Installation of the new server can be performed while the application is executing on the
POWER6 server. When the POWER7 processor technology based server is ready, the
application can be migrated to its new hosting server without application down time.
When adding POWER7 processor technology based servers to a POWER6 environment,
you get the additional flexibility to perform workload balancing across the whole set of
POWER6 and POWER7 processor technology based servers.
When performing server maintenance, you get the additional flexibility to utilize POWER6
Servers for hosting applications usually hosted on POWER7 processor technology based
servers, and the opposite situation, allowing you to perform this maintenance with no
application planned down time.
For more information about Live Partition Mobility and how to implement it, see IBM PowerVM
Live Partition Mobility, SG24-7460.
3.5.7 Active Memory Sharing
Active Memory Sharing is an IBM PowerVM advanced memory virtualization technology that
provides system memory virtualization capabilities to IBM Power Systems, allowing multiple
partitions to share a common pool of physical memory. Active Memory Sharing is only
available with PowerVM Enterprise edition.
The physical memory of a IBM Power System server can be assigned to multiple partitions
either in a dedicated mode or a shared mode. The system administrator has the capability to
assign part of the physical memory to a partition and other physical memory to a pool that is
shared by other partitions. A single partition can have either dedicated or shared memory.
Note: A new Trial PowerVM Live Partition Mobility feature (#ELPM) is available on multiple
POWER7 machine type models, which will enable clients to upgrade from PowerVM
Standard Edition to PowerVM Enterprise Edition at no charge for 60 days. At the
conclusion of the trial period clients can place an upgrade order for permanent PowerVM
Enterprise Edition to maintain continuity. At the end of the trial period (60 days), the client's
system will automatically return to PowerVM Standard Edition.
126 IBM Power 720 and 740: Technical Overview and Introduction
With a pure dedicated memory model, it is system administrator’s task to optimize available
memory distribution among partitions. When a partition suffers degradation due to memory
constraints and other partitions have unused memory, the administrator can manually react
by issuing a dynamic memory reconfiguration.
With a shared memory model it is the system that automatically decides the optimal
distribution of the physical memory to partitions and adjusts the memory assignment based
on partition load. The administrator reserves physical memory for the shared memory pool,
assigns partitions to the pool, and provides access limits to the pool.
Active Memory Sharing can be exploited to increase memory utilization on the system either
by decreasing the global memory requirement or by allowing the creation of additional
partitions on an existing system. Active Memory Sharing can be used in parallel with Active
Memory Expansion on a system running a mixed workload of several operating systems.
For example, AIX partitions can take advantage of Active Memory Expansion while other
operating systems take advantage of Active Memory Sharing.
For additional information regarding Active Memory Sharing, see PowerVM Virtualization
Active Memory Sharing, REDP-4470.
3.5.8 NPIV
N_Port ID virtualization (NPIV) is a technology that allows multiple logical partitions to access
independent physical storage through the same physical Fibre Channel adapter. This adapter
is attached to a Virtual I/O Server partition, which acts only as a pass-through managing the
data transfer through the POWER Hypervisor.
Each partition using NPIV is identified by a pair of unique worldwide port names, enabling you
to connect each partition to independent physical storage on a SAN. Unlike virtual SCSI, only
the client partitions see the disk.
For additional information about NPIV, see the following Redbooks publications:
IBM PowerVM Virtualization Managing and Monitoring, SG24-7590
PowerVM Migration from Physical to Virtual Storage, SG24-7825
NPIV is supported with PowerVM Express, Standard, and Enterprise Editions, on all
POWER7 processor-based servers and IBM Power Architecture technology-based blade
servers, hosted by VIOS 2.1.3 or later and LPARS using AIX 5.3, AIX 6.1, IBM i 6.1.1, SLES
11, and RHEL 5.4, or later.
3.5.9 Operating System support for PowerVM
Table 3-6 summarizes the PowerVM features supported by the operating systems compatible
with the POWER7 processor-based servers.
Table 3-6 PowerVM features supported by AIX, IBM i and Linux
Feature AIX
5.3
AIX
6.1
AIX
7.1
IBM i
6.1.1
IBM i
7.1
RHEL
5.5
SLES 10
SP3
SLES 11
SP1
Simultaneous
Multi-Threading (SMT)
Yes1
Yes2
Yes Yes5
Yes Yes1
Yes1
Yes
DLPAR I/O adapter
add/remove
Yes Yes Yes Yes Yes Yes Yes Yes
Chapter 3. Virtualization 127
1 Only supports two threads.
2 AIX 6.1 up to TL4 SP2 only supports two threads, and supports four threads as of TL4 SP3.
3 Available on selected models.
4 On AIX 6.1 with TL4 SP2 and later.
5 IBM i 6.1.1 and up support SMT4.
3.5.10 POWER7-specific Linux programming support
The IBM Linux Technology Center (LTC) contributes to the development of Linux by providing
support for IBM hardware in Linux distributions. In particular, the LTC makes tools and code
available to the Linux communities to take advantage of the POWER7 technology, and
develop POWER7 optimized software.
Table 3-7 summarizes the support of specific programming features for various versions of
Linux.
Table 3-7 Linux support for POWER7 features
DLPAR processor
add/remove
Yes Yes Yes Yes Yes Yes Yes Yes
DLPAR memory add Yes Yes Yes Yes Yes Yes Yes Yes
DLPAR memory
remove
Yes Yes Yes Yes Yes No No Yes
Capacity on Demand 3
Yes Yes Yes Yes Yes Yes Yes Yes
Micro-Partitioning Yes Yes Yes Yes Yes Yes Yes Yes
Shared Dedicated
Capacity
Yes Yes Yes Yes Yes Yes Yes Yes
Multiple Shared
Processor Pools
Yes Yes Yes Yes Yes Yes Yes Yes
Virtual I/O Server Yes Yes Yes Yes Yes Yes Yes Yes
IVM Yes Yes Yes Yes Yes Yes Yes Yes
Virtual SCSI Yes Yes Yes Yes Yes Yes Yes Yes
Virtual Ethernet Yes Yes Yes Yes Yes Yes Yes Yes
NPIV Yes Yes Yes Yes Yes Yes No Yes
Live Partition Mobility Yes Yes Yes No No Yes Yes Yes
Workload Partitions No Yes Yes No No No No No
Active Memory Sharing Yes Yes Yes Yes Yes No No Yes
Active Memory
Expansion
No Yes4
Yes No No No No No
Feature AIX
5.3
AIX
6.1
AIX
7.1
IBM i
6.1.1
IBM i
7.1
RHEL
5.5
SLES 10
SP3
SLES 11
SP1
Features Linux Releases Comments
SLES 10 SP3 SLES 11 SP1 RHEL 5.5
POWER6
compatibility mode
Yes Yes Yes
128 IBM Power 720 and 740: Technical Overview and Introduction
For information regarding Advanced Toolchain, see the “How to use Advance Toolchain for
Linux” website:
http://www.ibm.com/developerworks/wikis/display/hpccentral/How+to+use+Advance+Tool
chain+for+Linux+on+POWER
You can also see the University of Illinois Linux on Power Open Source Repository:
http://ppclinux.ncsa.illinois.edu
ftp://linuxpatch.ncsa.uiuc.edu/toolchain/at/at05/suse/SLES_11/release_notes.at05-2
.1-0.html
ftp://linuxpatch.ncsa.uiuc.edu/toolchain/at/at05/redhat/RHEL5/release_notes.at05-2
.1-0.html
3.6 System Planning Tool
The IBM System Planning Tool (SPT) helps you design a system or systems to be partitioned
with logical partitions. You can also plan for and design non-partitioned systems using the
SPT. The resulting output of your design is called a system plan, which is stored in a .sysplan
file. This file can contain plans for a single system or multiple systems. The .sysplan file can
be used:
To create reports
As input to the IBM configuration tool (e-Config)
To create and deploy partitions on your systems automatically
System plans generated by the SPT can be deployed on the system by the Hardware
Management Console (HMC) or the Integrated Virtualization Manager (IVM).
POWER7 mode No Yes No
Strong Access
Ordering
No Yes No To improve Lx86
performance
Scale to 256 cores
/ 1024 threads
No Yes No Base OS support
available.
4-way SMT No Yes No
VSX Support No Yes No
Distro toolchain
mcpu/mtune=p7
No Yes No
Advance Toolchain
Support
Yes; execution
restricted to
POWER6
instructions
Yes Yes; execution
restricted to
POWER6
instructions
Alternative IBM gnu
Toolchain
64k base page size No Yes Yes
Tickless idle No Yes No Improved energy
utilization and
virtualization of
partially to fully idle
partitions.
Features Linux Releases Comments
SLES 10 SP3 SLES 11 SP1 RHEL 5.5
Chapter 3. Virtualization 129
You can create an entirely new system configuration, or you can create a system
configuration based upon any of the following considerations:
Performance data from an existing system that the new system is to replace
Performance estimates anticipating future workloads that you must support
Sample systems that you can customize to fit your needs
Integration between the SPT and both the Workload Estimator (WLE) and IBM Performance
Management (PM) allows you to create a system that is based upon performance and
capacity data from an existing system or one based on new workloads that you specify.
Before you order a system, you can use the SPT to determine what you have to order to
support your workload. You can also use the SPT to determine how you can partition a
system that you already have.
Use the IBM System Planning Tool to estimate POWER Hypervisor requirements and
determine the memory resources required for all partitioned and non-partitioned servers.
Figure 3-13 shows the estimated Hypervisor memory requirements based on sample
partition requirements.
Note: Ask your IBM representative or Business Partner representative to use the
Customer Specified Placement manufacturing option if you want to automatically deploy
your partitioning environment on a new machine. SPT looks for the resource allocation to
be the same as that specified on your .sysplan file.
130 IBM Power 720 and 740: Technical Overview and Introduction
Figure 3-13 IBM System Planning Tool window showing Hypervisor memory requirements
For the SPT and its supporting documentation, see the IBM System Planning Tool site at:
http://www.ibm.com/systems/support/tools/systemplanningtool
© Copyright IBM Corp. 2010. All rights reserved. 131
Chapter 4. Continuous availability and
manageability
This chapter provides information about IBM reliability, availability, and serviceability (RAS)
design and features. This set of technologies, implemented on IBM Power Systems servers,
provides the possibility to improve your architecture’s total cost of ownership (TCO) by
reducing unplanned down time.
The elements of RAS can be described as follows:
Reliability: Indicates how infrequently a defect or fault in a server manifests itself.
Availability: Indicates how infrequently the functionality of a system or application is
impacted by a fault or defect.
Serviceability: Indicates how well faults and their effects are communicated to users and
services and how efficiently and nondisruptively the faults are repaired.
Each successive generation of IBM servers is designed to be more reliable than the previous
server family. POWER7 processor-based servers have new features to support new levels of
virtualization, help ease administrative burden and increase system utilization.
Reliability starts with components, devices, and subsystems designed to be fault-tolerant.
POWER7 uses lower voltage technology improving reliability with stacked latches to reduce
soft error susceptibility. During the design and development process, subsystems go through
rigorous verification and integration testing processes. During system manufacturing,
systems go through a thorough testing process to help ensure high product quality levels.
The processor and memory subsystem contain a number of features designed to avoid or
correct environmentally induced, single-bit, intermittent failures as well as handle solid faults
in components, including selective redundancy to tolerate certain faults without requiring an
outage or parts replacement.
4
132 IBM Power 720 and 740: Technical Overview and Introduction
4.1 Reliability
Highly reliable systems are built with highly reliable components. On IBM POWER
processor-based systems, this basic principle is expanded upon with a clear design for
reliability architecture and methodology. A concentrated, systematic, architecture-based
approach is designed to improve overall system reliability with each successive generation of
system offerings.
4.1.1 Designed for reliability
Systems designed with fewer components and interconnects have fewer opportunities to fail.
Simple design choices such as integrating processor cores on a single POWER chip can
dramatically reduce the opportunity for system failures. In this case, an 8-core server can
include one-fourth as many processor chips (and chip socket interfaces) as with a double
CPU-per-processor design. Not only does this case reduce the total number of system
components, it reduces the total amount of heat generated in the design, resulting in an
additional reduction in required power and cooling components. POWER7 processor-based
servers also integrate L3 cache into the processor chip for a higher integration of parts.
Parts selection also plays a critical role in overall system reliability. IBM uses three grades of
components; grade 3 defined as industry standard (off-the-shelf). As shown in Figure 4-1,
using stringent design criteria and an extensive testing program, the IBM manufacturing team
can produce grade 1 components that are expected to be 10 times more reliable than
industry standard. Engineers select grade 1 parts for the most critical system components.
Newly introduced organic packaging technologies, rated grade 5, achieve the same reliability
as grade 1 parts.
Figure 4-1 Component failure rates
Component failure rates
0
0.2
0.4
0.6
0.8
1
Grade 3 Grade 1 Grade 5
Chapter 4. Continuous availability and manageability 133
4.1.2 Placement of components
Packaging is designed to deliver both high performance and high reliability. For example, the
reliability of electronic components is directly related to their thermal environment, that is,
large decreases in component reliability are directly correlated with relatively small increases
in temperature; POWER processor-based systems are carefully packaged to ensure
adequate cooling. Critical system components such as the POWER7 processor chips are
positioned on printed circuit cards so they receive fresh air during operation. In addition,
POWER processor-based systems are built with redundant, variable-speed fans that can
automatically increase output to compensate for increased heat in the central electronic
complex.
4.1.3 Redundant components and concurrent repair
High opportunity components—those that most affect system availability—are protected with
redundancy and the ability to be repaired concurrently.
The use of redundant components allows the system to remain operational:
POWER7 cores, which include redundant bits in L1 instruction and data caches, L2
caches, and L2 and L3 directories
Power 720 and 740 main memory DIMMs, which use an innovative ECC algorithm from
IBM research that improves bit error correction and memory failures
Redundant and hot-swap cooling
Redundant and hot-swap power supplies
Redundant 12X loops to I/O subsystem
For maximum availability, be sure to connect power cords from the same system to two
separate Power Distribution Units (PDUs) in the rack, and to connect each PDU to
independent power sources. Tower form factor power cords must be plugged to two
independent power sources in order to achieve maximum availability.
4.2 Availability
IBM hardware and microcode capability to continuously monitor execution of hardware
functions is generally described as the process of First Failure Data Capture (FFDC). This
process includes the strategy of predictive failure analysis, which refers to the ability to track
intermittent correctable errors and to vary components off-line before they reach the point of
hard failure causing a system outage, and without the need to recreate the problem.
The POWER7 family of systems continues to offer and introduce significant enhancements
designed to increase system availability to drive towards a high availability objective with
hardware components that can perform the following automatic functions:
Self-diagnose and self-correct during run time
Automatically reconfigure to mitigate potential problems from suspect hardware
Self-heal or automatically substitute good components for failing components
Tip: Check your configuration for optional redundant components before ordering your
system.
Note: POWER7 processor-based servers are independent of the operating system for
error detection and fault isolation within the central electronics complex.
134 IBM Power 720 and 740: Technical Overview and Introduction
Throughout this chapter we describe IBM POWER7 processor-based systems technologies
focused on keeping a system up and running. For a specific set of functions focused on
detecting errors before they become serious enough to stop computing work, see 4.3.1,
“Detecting errors” on page 183.
4.2.1 Partition availability priority
Also available is the ability to assign availability priorities to partitions. If an alternate
processor recovery event requires spare processor resources and there are no other means
of obtaining the spare resources, the system determines which partition has the lowest
priority and attempts to claim the needed resource. On a properly configured POWER
processor-based server, this approach allows that capacity to first be obtained from a low
priority partition instead of a high priority partition.
This capability is relevant to the total system availability because it gives the system an
additional stage before an unplanned outage. In the event that insufficient resources exist to
maintain full system availability, these servers attempt to maintain partition availability by
user-defined priority.
Partition availability priority is assign to partitions using a weight value or integer rating. The
lowest priority partition is rated at 0 (zero) and the highest priority partition is valued at 255.
The default value is set at 127 for standard partitions and 192 for Virtual I/O Server (VIOS)
partitions. You can vary the priority of individual partitions.
Partition availability priorities can be set for both dedicated and shared processor partitions.
The POWER Hypervisor uses the relative partition weight value among active partitions to
favor higher priority partitions for processor sharing, adding and removing processor capacity,
and favoring higher priority partitions for normal operation.
Note that the partition specifications for minimum, desired, and maximum capacity are also
taken into account for capacity-on-demand options, and if total system-wide processor
capacity becomes disabled because of deconfigured failed processor cores. For example, if
total system-wide processor capacity is sufficient to run all partitions, at least with the
minimum capacity, the partitions are allowed to start or continue running. If processor
capacity is insufficient to run a partition at its minimum value, then starting that partition
results in an error condition that must be resolved.
4.2.2 General detection and deallocation of failing components
Runtime correctable or recoverable errors are monitored to determine if there is a pattern of
errors. If these components reach a predefined error limit, the service processor initiates an
action to deconfigure the faulty hardware, helping to avoid a potential system outage and to
enhance system availability.
Persistent deallocation
To enhance system availability, a component that is identified for deallocation or
deconfiguration on a POWER processor-based system is flagged for persistent deallocation.
Component removal can occur either dynamically (while the system is running) or at
boot-time (IPL), depending both on the type of fault and when the fault is detected.
Chapter 4. Continuous availability and manageability 135
In addition, runtime unrecoverable hardware faults can be deconfigured from the system after
the first occurrence. The system can be rebooted immediately after failure and resume
operation on the remaining stable hardware. This way prevents the same faulty hardware
from affecting system operation again; the repair action is deferred to a more convenient, less
critical time.
The following persistent deallocation functions are included:
Processor
L2/L3 cache lines (cache lines are dynamically deleted)
Memory
Deconfigure or bypass failing I/O adapters
Figure 4-2 AMSI Auto Power Restart setting window interface
Processor instruction retry
As in POWER6, the POWER7 processor has the ability to do processor instruction retry and
alternate processor recovery for a number of core related faults. Doing this significantly
reduces exposure to both permanent and intermittent errors in the processor core.
Note: The auto-restart (reboot) option has to be enabled from the Advanced System
Manager Interface or from the Control (Operator) Panel. Figure 4-2 shows this option using
the ASMI.
136 IBM Power 720 and 740: Technical Overview and Introduction
Intermittent errors, often due to cosmic rays or other sources of radiation, are generally not
repeatable.
With the instruction retry function, when an error is encountered in the core, in caches and
certain logic functions, the POWER7 processor first automatically retries the instruction. If the
source of the error was truly transient, the instruction succeeds and the system can continue
as before.
Note that on IBM systems prior to POWER6, such an error typically caused a checkstop.
Alternate processor retry
Hard failures are more difficult, being permanent errors that will be replicated each time the
instruction is repeated. Retrying the instruction does not help in this situation because the
instruction will continue to fail.
As in POWER6, POWER7 processors have the ability to extract the failing instruction from the
faulty core and retry it elsewhere in the system for a number of faults, after which the failing
core is dynamically deconfigured and scheduled for replacement.
Dynamic processor deallocation
Dynamic processor deallocation enables automatic deconfiguration of processor cores when
patterns of recoverable core-related faults are detected. Dynamic processor deallocation
prevents a recoverable error from escalating to an unrecoverable system error, which might
otherwise result in an unscheduled server outage. Dynamic processor deallocation relies on
the service processor’s ability to use FFDC-generated recoverable error information to notify
the POWER Hypervisor when a processor core reaches its predefined error limit. Then the
POWER Hypervisor dynamically deconfigures the failing core and is called out for
replacement. The entire process is transparent to the partition owning the failing instruction.
Single processor checkstop
As in the POWER6 processor, the POWER7 processor provides single core check stopping
for certain processor logic, command, or control errors that cannot be handled by the
availability enhancements in the preceding section.
This significantly reduces the probability of any one processor affecting total system
availability by containing most processor checkstops to the partition that was using the
processor at the time full checkstop goes into effect.
Even with all these availability enhancements to prevent processor errors from affecting
system-wide availability into play, there will be errors that can result in a system-wide outage.
4.2.3 Memory protection
A memory protection architecture that provides good error resilience for a relatively small L1
cache might be very inadequate for protecting the much larger system main store. Therefore,
a variety of protection methods are used in POWER processor-based systems to avoid
uncorrectable errors in memory.
Memory protection plans must take into account many factors, including these:
Size
Desired performance
Memory array manufacturing characteristics
Chapter 4. Continuous availability and manageability 137
POWER7 processor-based systems have a number of protection schemes designed to
prevent, protect, or limit the effect of errors in main memory:
Chipkill:
Chipkill is an enhancement that enables a system to sustain the failure of an entire DRAM
chip. An ECC word uses 18 DRAM chips from two DIMM pairs, and a failure on any of the
DRAM chips can be fully recovered by the ECC algorithm. The system can continue
indefinitely in this state with no performance degradation until the failed DIMM can be
replaced.
72-byte ECC:
In POWER7, an ECC word consists of 72 bytes of data. Of these, 64 are used to hold
application data. The remaining eight bytes are used to hold check bits and additional
information about the ECC word.
This innovative ECC algorithm from IBM research works on DIMM pairs on a rank basis (a
rank is a group of 9 DRAM chips on the Power 710 and 730). With this ECC code, the
system can dynamically recover from an entire DRAM failure (Chipkill) but can also correct
an error even if another symbol (a byte, accessed by a 2-bit line pair) experiences a fault
(an improvement from the Double Error Detection/Single Error Correction ECC
implementation found on the POWER6 processor-based systems).
Hardware scrubbing:
Hardware scrubbing is a method used to deal with intermittent errors. IBM POWER
processor-based systems periodically address all memory locations; any memory
locations with a correctable error are rewritten with the correct data.
CRC:
The bus that is transferring data between the processor and the memory uses CRC error
detection with a failed operation-retry mechanism and the ability to dynamically retune bus
parameters when a fault occurs. In addition, the memory bus has spare capacity to
substitute a data bit-line, whenever it is determined to be faulty.
POWER7 memory subsystem
The POWER7 processor chip contains two memory controllers with four channels per
Memory Controller. Each channel connects to a single DIMM, but as the channels work in
pairs, a processor chip can address four DIMM pairs, two pairs per memory controller.
The bus transferring data between the processor and the memory uses CRC error detection
with a failed operation retry mechanism and the ability to dynamically retune bus parameters
when a fault occurs. In addition, the memory bus has spare capacity to substitute a spare
data bit-line for one which is determined to be faulty.
Figure 4-3 on page 138 shows a POWER7 processor chip, with its memory interface,
consisting of two controllers and four DIMMs per controller. Advanced memory buffer chips
are exclusive to IBM and help to increase performance, acting as read/write buffers. On the
Power 770 and 780, the advanced memory buffer chips are integrated to the DIMM that they
support. Power 750 and 755 uses only one memory controller, Advanced memory buffer
chips are on the system planar and support two DIMMs each.
138 IBM Power 720 and 740: Technical Overview and Introduction
Figure 4-3 POWER7 memory subsystem
Memory page deallocation
While coincident cell errors in separate memory chips are statistically rare, IBM POWER
processor-based systems can contain these errors using a memory page deallocation
scheme for partitions running IBM AIX and the IBM i operating systems as well as for memory
pages owned by the POWER Hypervisor. If a memory address experiences an uncorrectable
or repeated correctable single cell error, the Service Processor sends the memory page
address to the POWER Hypervisor to be marked for deallocation.
Pages used by the POWER Hypervisor are deallocated as soon as the page is released.
In other cases, the POWER Hypervisor notifies the owning partition that the page must be
deallocated. Where possible, the operating system moves any data currently contained in that
memory area to another memory area and removes the page(s) associated with this error
from its memory map, no longer addressing these pages. The operating system performs
memory page deallocation without any user intervention and is transparent to end users and
applications.
The POWER Hypervisor maintains a list of pages marked for deallocation during the current
platform IPL. During a partition IPL, the partition receives a list of all the bad pages in its
address space. In addition, if memory is dynamically added to a partition (through a dynamic
LPAR operation), the POWER Hypervisor warns the operating system when memory pages
are included that need to be deallocated.
Finally, If an uncorrectable error in memory is discovered, the logical memory block
associated with the address with the uncorrectable error is marked for deallocation by the
POWER Hypervisor. This deallocation will take effect on a partition reboot if the logical
memory block is assigned to an active partition at the time of the fault.
Ctrl
DIMMCtrl
DIMM
Memory Controller
Ctrl
DIMMCtrl
DIMM
Buffer Buffer
Ctrl
DIMMCtrl
DIMM
Memory Controller
Ctrl
DIMMCtrl
DIMM
BufferBuffer
Port Port PortPort
POWER7
Core
256 KB L2
POWER7
Core
256 KB L2
POWER7
Core
256 KB L2
POWER7
Core
256 KB L2
POWER7
Core
256 KB L2
POWER7
Core
256 KB L2
POWER7
Core
256 KB L2
POWER7
Core
256 KB L2
32 MB L3 Cache
SMPFabric
GX
Chapter 4. Continuous availability and manageability 139
In addition, the system will deallocate the entire memory group associated with the error on
all subsequent system reboots until the memory is repaired. This precaution is intended to
guard against future uncorrectable errors while waiting for parts replacement.
Memory persistent deallocation
Defective memory discovered at boot time is automatically switched off. If the Service
Processor detects a memory fault at boot time, it marks the affected memory as bad so it is
not to be used on subsequent reboots.
If the Service Processor identifies faulty memory in a server that includes CoD memory, the
POWER Hypervisor attempts to replace the faulty memory with available CoD memory. Faulty
resources are marked as deallocated and working resources are included in the active
memory space. Because these activities reduce the amount of CoD memory available for
future use, repair of the faulty memory must be scheduled as soon as is convenient.
Upon reboot, if not enough memory is available to meet minimum partition requirements the
POWER Hypervisor will reduce the capacity of one or more partitions.
Depending on the configuration of the system, the HMC Service Focal Point, OS Service
Focal Point, or Service Processor will receive a notification of the failed component, and will
trigger a service call.
4.2.4 Cache protection
POWER7 processor-based systems are designed with cache protection mechanisms,
including cache line delete in both L2 and L3 arrays, Processor Instruction Retry and
Alternate Processor Recovery protection on L1-I and L1-D, and redundant “Repair” bits in
L1-I, L1-D, and L2 caches, as well as L2 and L3 directories.
L1 instruction and data array protection
The POWER7 processor instruction and data caches are protected against intermittent errors
using Processor Instruction Retry and against permanent errors by Alternate Processor
Recovery, both mentioned earlier. L1 cache is divided into sets. POWER7 processor can
deallocate all but one before doing a Processor Instruction Retry.
In addition, faults in the Segment Lookaside Buffer (SLB) array are recoverable by the
POWER Hypervisor. The SLB is used in the core to perform address translation calculations.
L2 and L3 array protection
The L2 and L3 caches in the POWER7 processor are protected with double-bit detect
single-bit correct error detection code (ECC). Single-bit errors are corrected before forwarding
to the processor, and subsequently written back to L2/L3.
In addition, the caches maintain a cache line delete capability. A threshold of correctable
errors detected on a cache line can result in the data in the cache line being purged and the
cache line removed from further operation without requiring a reboot. An ECC uncorrectable
error detected in the cache can also trigger a purge and delete of the cache line. This results
in no loss of operation because an unmodified copy of the data can be held on system
memory to reload the cache line from main memory. Modified data is handled through Special
Uncorrectable Error handling.
L2 and L3 deleted cache lines are marked for persistent deconfiguration on subsequent
system reboots until they can be replaced.
140 IBM Power 720 and 740: Technical Overview and Introduction
4.2.5 Special Uncorrectable Error handling
While it is rare, an uncorrectable data error can occur in memory or a cache. IBM POWER
processor-based systems attempt to limit the impact of an uncorrectable error to the least
possible disruption, using a well-defined strategy that first considers the data source.
Sometimes, an uncorrectable error is temporary in nature and occurs in data that can be
recovered from another repository, for example:
Data in the instruction L1 cache is never modified within the cache itself. Therefore, an
uncorrectable error discovered in the cache is treated like an ordinary cache miss, and
correct data is loaded from the L2 cache.
The L2 and L3 cache of the POWER7 processor-based systems can hold an unmodified
copy of data in a portion of main memory. In this case, an uncorrectable error simply
triggers a reload of a cache line from main memory.
In cases where the data cannot be recovered from another source, a technique called Special
Uncorrectable Error (SUE) handling is used to prevent an uncorrectable error in memory or
cache from immediately causing the system to terminate. Rather, the system tags the data
and determines whether it will ever be used again:
If the error is irrelevant, it will not force a checkstop.
If the data is used, termination can be limited to the program / kernel or hypervisor owning
the data; or freeze of the I/O adapters controlled by an I/O hub controller if data is going to
be transferred to an I/O device.
When an uncorrectable error is detected, the system modifies the associated ECC word,
thereby signaling to the rest of the system that the “standard” ECC is no longer valid. The
Service Processor is then notified, and takes appropriate actions. When running AIX V5.2 or
later, or Linux, and a process attempts to use the data, the operating system is informed of
the error and might terminate, or only terminate a specific process associated with the corrupt
data, depending on the operating system and firmware level and whether the data was
associated with a kernel or non-kernel process.
It is only in the case where the corrupt data is used by the POWER Hypervisor that the entire
system must be rebooted, thereby preserving overall system integrity.
Depending on system configuration and source of the data, errors encountered during I/O
operations might not result in a machine check. Instead, the incorrect data is handled by the
processor host bridge (PHB) chip. When the PHB chip detects a problem, it rejects the data,
preventing data being written to the I/O device.
The PHB then enters a freeze mode halting normal operations. Depending on the model and
type of I/O being used, the freeze might include the entire PHB chip, or simply a single bridge.
resulting in the loss of all I/O operations that use the frozen hardware until a power-on reset of
the PHB is done. The impact to partitions depends on how the I/O is configured for
redundancy. In a server configured for failover availability, redundant adapters spanning
multiple PHB chips can enable the system to recover transparently, without partition loss.
4.2.6 PCI extended error handling
IBM estimates that PCI adapters can account for a significant portion of the hardware-based
errors on a large server. Whereas servers that rely on boot-time diagnostics can identify
failing components to be replaced by hot-swap and reconfiguration, runtime errors pose a
more significant problem.
Chapter 4. Continuous availability and manageability 141
PCI adapters are generally complex designs involving extensive on-board instruction
processing, often on embedded micro controllers. They tend to use industry standard grade
components with an emphasis on product cost relative to high reliability. In certain cases, they
might be more likely to encounter internal microcode errors, or many of the hardware errors
described for the rest of the server.
The traditional means of handling these problems is through adapter internal error reporting
and recovery techniques in combination with operating system device driver management
and diagnostics. In certain cases, an error in the adapter might cause transmission of bad
data on the PCI bus itself, resulting in a hardware detected parity error and causing a global
machine check interrupt, eventually requiring a system reboot to continue.
PCI extended error handling (EEH) enabled adapters respond to a special data packet
generated from the affected PCI slot hardware by calling system firmware, which will examine
the affected bus, allow the device driver to reset it, and continue without a system reboot. For
Linux, EEH support extends to the majority of frequently used devices, although various
third-party PCI devices might not provide native EEH support.
To detect and correct PCIe bus errors POWER7 processor-based systems use CRC
detection and instruction retry correction, while for PCI-X use ECC.
Figure 4-4 shows the location and various mechanisms used throughout the I/O subsystem
for PCI extended error handling.
Figure 4-4 PCI extended error handling
PCIe
Adapter
PCI-X
Adapter
Parity error
Parity error
I/O drawer concurrent add
CRC with
retry or ECC
PCI Bridge Enhanced
Error Handling
PCI-X to PCI-X
POWER7
12X Channel
Hub
PCI-X
Bridge
PCI-X
Bridge
POWER7
12X Channel
Hub
12X Channel –
PCIe Bridge
GX+ / GX++ bus
adapter
12x channel failover
support
PCI Bus Enhanced Error
Handling
142 IBM Power 720 and 740: Technical Overview and Introduction
4.3 Serviceability
IBM Power Systems design considers both IBM and client needs. The IBM Serviceability
Team has enhanced the base service capabilities and continues to implement a strategy that
incorporates best-of-breed service characteristics from diverse IBM systems offerings.
Serviceability includes system installation, system upgrades and downgrades (MES), and
system maintenance and repair.
The goal of the IBM Serviceability Team is to design and provide the most efficient system
service environment, which includes the following benefits:
Easy access to service components; design for Customer Set Up (CSU), Customer
Installed Features (CIF), and Customer Replaceable Units (CRU)
On demand service education
Error detection and fault isolation (ED/FI)
First-failure data capture (FFDC)
An automated guided repair strategy that uses common service interfaces for a converged
service approach across multiple IBM server platforms
By delivering on these goals, IBM Power Systems servers enable faster and more accurate
repair, and reduce the possibility of human error.
Client control of the service environment extends to firmware maintenance on all of the
POWER processor-based systems. This strategy contributes to higher systems availability
with reduced maintenance costs.
This section provides an overview of the progressive steps of error detection, analysis,
reporting, notifying, and repairing that are found in all POWER processor-based systems.
The term servicer, when used in the context of this document, denotes the person tasked with
performing service related actions on a system. For an item designated as a Customer
Replaceable Unit (CRU), the servicer might be the client. In other cases, for Field
Replaceable Unit (FRU) items, the servicer might be an IBM representative or an authorized
warranty service provider.
Service can be divided into three main categories:
Service Components The basic service related building blocks
Service Functions Service procedures or processes containing one or more
service components
Service Operating Environment The specific system operating environment which
specifies how service functions are provided by the
various service components
The basic component of service is a Serviceable Event.
Serviceable events are platform, regional, and local error occurrences that require a service
action (repair). This action can include a call home to report the problem so that the repair
can be assessed by a trained service representative. In all cases, the client is notified of the
event. Event notification includes a clear indication of when servicer intervention is required to
rectify the problem. The intervention might be a service action that the client can perform or it
might require a service provider.
Chapter 4. Continuous availability and manageability 143
Serviceable events are classified as follows:
1. Recoverable: This is a correctable resource or function failure. The server remains
available, but there might be some decrease in operational performance available for
client’s workload (applications).
2. Unrecoverable: This is an uncorrectable resource or function failure. In this instance, there
is potential degradation in availability and performance, or loss of function to the client’s
workload.
3. Predictable (using thresholds in support of Predictive Failure Analysis): This is a
determination that continued recovery of a resource or function might lead to degradation
of performance or failure of the client’s workload. Although the server remains fully
available, if the condition is not corrected, an unrecoverable error might occur.
4. Informational: This is notification that a resource or function:
– Is out-of or returned-to specification and might require user intervention.
– Requires user intervention to complete a system task(s).
Platform errors are faults that affect all partitions in various ways. They are detected in the
CEC by the Service Processor, the System Power Control Network, or the Power Hypervisor.
When a failure occurs in these components, the POWER Hypervisor notifies each partition’s
operating system to execute any required precautionary actions or recovery methods. The
OS is required to report these kinds of errors as serviceable events to the Service Focal Point
application because, by the definition, they affect the partition.
Platform errors are faults related to:
The Central Electronics Complex (CEC); that part of the server composed of the central
processor units, memory, storage controls, and the I/O hubs.
The power and cooling subsystems.
The firmware used to initialize the system and diagnose errors.
Regional errors are faults that affect some, but not all partitions. They are detected by the
POWER Hypervisor or the Service Processor. Examples of these are RIO bus, RIO bus
adapter, PHB, multi-adapter bridges, I/O hub, and errors on I/O units (except adapters,
devices, and their connecting hardware).
Local errors are faults detected in a partition (by the partition firmware or the operating
system) for resources owned only by that partition. The POWER Hypervisor and Service
Processor are not aware of these errors. Local errors might include “secondary effects” that
result from platform errors preventing partitions from accessing partition-owned resources.
Examples include PCI adapters or devices assigned to a single partition. If a failure occurs to
one of these resources, only a single operating system partition need be informed.
This section provides an overview of the progressive steps of error detection, analysis,
reporting, notifying, and repairing that are found in all POWER processor-based systems.
4.3.1 Detecting
The first and most crucial component of a solid serviceability strategy is the ability to
accurately and effectively detect errors when they occur. Although not all errors are a
guaranteed threat to system availability, those that go undetected can cause problems
because the system does not have the opportunity to evaluate and act if necessary. POWER
processor-based systems employ IBM System z® server-inspired error detection
mechanisms that extend from processor cores and memory to power supplies and hard
drives.
144 IBM Power 720 and 740: Technical Overview and Introduction
Service processor
The service processor is a microprocessor that is powered separately from the main
instruction processing complex. The service processor provides the capabilities for the
following features:
POWER Hypervisor (system firmware) and Hardware Management Console connection
surveillance
Various remote power control options
Reset and boot features
Environmental monitoring:
The service processor monitors the server’s built-in temperature sensors, sending
instructions to the system fans to increase rotational speed when the ambient temperature
is above the normal operating range. Using an architected operating system interface, the
service processor notifies the operating system of potential environmentally related
problems so that the system administrator can take appropriate corrective actions before a
critical failure threshold is reached.
The service processor can also post a warning and initiate an orderly system shutdown
under the following circumstances:
– The operating temperature exceeds the critical level (for example, failure of air
conditioning or air circulation around the system).
– The system fan speed is out of operational specification, for example, because of
multiple fan failures.
– The server input voltages are out of operational specification.
The service processor can immediately shut down a system when:
– Temperature exceeds the critical level or remains above the warning level for too long.
– Internal component temperatures reach critical levels.
– Non-redundant fan failures occur.
Placing calls:
On systems without a Hardware Management Console, the service processor can place
calls to report surveillance failures with the POWER Hypervisor, critical environmental
faults, and critical processing faults even when the main processing unit is inoperable.
Mutual surveillance:
The service processor monitors the operation of the POWER Hypervisor firmware during
the boot process and watches for loss of control during system operation. It also allows the
POWER Hypervisor to monitor service processor activity. The service processor can take
appropriate action, including calling for service, when it detects the POWER Hypervisor
firmware has lost control. Likewise, the POWER Hypervisor can request a service
processor repair action if necessary.
Availability:
The auto-restart (reboot) option, when enabled, can reboot the system automatically
following an unrecoverable firmware error, firmware hang, hardware failure, or
environmentally induced (AC power) failure.
Fault monitoring:
Built-in self-test (BIST) checks processor, cache, memory, and associated hardware that
is required for proper booting of the operating system, when the system is powered on at
the initial installation or after a hardware configuration change (for example, an upgrade).
If a non-critical error is detected or if the error occurs in a resource that can be removed
from the system configuration, the booting process is designed to proceed to completion.
Chapter 4. Continuous availability and manageability 145
The errors are logged in the system nonvolatile random access memory (NVRAM). When
the operating system completes booting, the information is passed from the NVRAM to the
system error log where it is analyzed by error log analysis (ELA) routines. Appropriate
actions are taken to report the boot-time error for subsequent service, if required
Concurrent access to the service processors menus of the Advanced System
Management Interface (ASMI):
This access allows nondisruptive abilities to change system default parameters,
interrogate service processor progress and error logs, set and reset server indicators,
(Guiding Light for midrange and high-end servers, Light Path for low end servers), indeed,
accessing all service processor functions without having to power-down the system to the
standby state. This way allows the administrator or service representative to dynamically
access the menus from any web browser-enabled console that is attached to the Ethernet
service network, concurrently with normal system operation.
Managing the interfaces for connecting uninterruptable power source systems to the
POWER processor-based systems, performing Timed Power-On (TPO) sequences, and
interfacing with the power and cooling subsystems.
Error checkers
IBM POWER processor-based systems contain specialized hardware detection circuitry that
is used to detect erroneous hardware operations. Error checking hardware ranges from parity
error detection coupled with processor instruction retry and bus retry, to ECC correction on
caches and system buses. All IBM hardware error checkers have distinct attributes:
Continuous monitoring of system operations to detect potential calculation errors
Attempts to isolate physical faults based on run time detection of each unique failure
Ability to initiate a wide variety of recovery mechanisms designed to correct the problem.
The POWER processor-based systems include extensive hardware and firmware
recovery logic.
Fault isolation registers
Error checker signals are captured and stored in hardware fault isolation registers (FIRs). The
associated logic circuitry is used to limit the domain of an error to the first checker that
encounters the error. In this way, run-time error diagnostics can be deterministic so that for
every check station, the unique error domain for that checker is defined and documented.
Ultimately, the error domain becomes the field-replaceable unit (FRU) call, and manual
interpretation of the data is not normally required.
First-failure data capture
The first-failure data capture (FFDC) error isolation technique ensures that when a fault is
detected in a system through error checkers or other types of detection methods, the root
cause of the fault will be captured without the need to re-create the problem or run an
extended tracing or diagnostics program.
For the vast majority of faults, a good FFDC design means that the root cause is detected
automatically without intervention by a service representative. Pertinent error data related to
the fault is captured and saved for analysis. In hardware, FFDC data is collected from the fault
isolation registers (FIRs) and from the associated logic. In firmware, this data consists of
return codes, function calls, and so forth.
FFDC check stations are carefully positioned within the server logic and data paths to ensure
that potential errors can be quickly identified and accurately tracked to a field-replaceable unit
(FRU).
146 IBM Power 720 and 740: Technical Overview and Introduction
This proactive diagnostic strategy is a significant improvement over the classic, less accurate
reboot and diagnose service approaches.
Figure 4-5 shows a schematic of a fault isolation register implementation.
Figure 4-5 Schematic of FIR implementation
Note: First Failure Data Capture plays a critical role in delivering servers that can
self-diagnose and self-heal. Using thousands of checkers (diagnostic probes) deployed at
critical junctures throughout the server, the system effectively “traps” hardware errors at
system run time.
The separately powered Service Processor is then used to analyze the checkers and
perform problem determination. Using this method, IBM no longer has to rely on an
intermittent “reboot and retry” error detection strategy, but knows with a degree of certainty
which part is having problems. In this automated approach, run-time error diagnostics can
be deterministic, so that for every check station, the unique error domain for that checker is
defined and documented. Ultimately, the error domain becomes the FRU (part) call, and
manual interpretation of the data is not normally required.
This architecture is also the basis for the IBM predictive failure analysis, because the
Service Processor can now count, and log, intermittent component errors, and can
deallocate or take other corrective actions when an error threshold is reached.
Memory
CPU
L2 / L3
Text
Text
Text
Text
Text
Text
Text
Text
Text
Text
Text
Text
Text
Text
Text
Text
L1
Disk
Text
Text
Text
Text
Text
Text
Text
Text Non-volatile
RAM
Service
Processor
Error checkers
Text Fault isolation register (FIR)
Unique fingerprint of each
captured error
Log error
Chapter 4. Continuous availability and manageability 147
Fault isolation
The service processor interprets error data that is captured by the FFDC checkers (saved in
the FIRs or other firmware-related data capture methods) in order to determine the root cause
of the error event.
Root cause analysis might indicate that the event is recoverable, meaning that a service
action point or need for repair has not been reached. Alternatively, it might indicate that a
service action point has been reached, where the event exceeded a pre-determined threshold
or was unrecoverable. Based on the isolation analysis, recoverable error threshold counts
might be incremented. No specific service action is necessary when the event is recoverable.
When the event requires a service action, additional required information is collected to
service the fault. For unrecoverable errors or for recoverable events that meet or exceed
their service threshold, meaning that a service action point has been reached, a request for
service is initiated through an error logging component.
4.3.2 Diagnosing
Using the extensive network of advanced and complementary error detection logic that is built
directly into hardware, firmware, and operating systems, the IBM Power Systems servers can
perform considerable self-diagnosis.
Boot time
When an IBM Power Systems server powers up, the service processor initializes system
hardware. Boot-time diagnostic testing uses a multitier approach for system validation,
starting with managed low level diagnostics that are supplemented with system firmware
initialization and configuration of I/O hardware, followed by OS-initiated software test routines.
The following boot-time diagnostic routines are included:
Built-in self-tests (BIST) for both logic components and arrays ensure the internal integrity
of components. Because the service processor assists in performing these tests, the
system is enabled to perform fault determination and isolation, whether or not the system
processors are operational. Boot-time BISTs can also find faults undetectable by
processor-based power-on self-test (POST) or diagnostics
Wire-tests discover and precisely identify connection faults between components such as
processors, memory, or I/O hub chips.
Initialization of components such as ECC memory, typically by writing patterns of data and
allowing the server to store valid ECC data for each location, can help isolate errors.
To minimize boot time, the system determines which of the diagnostics are required to be
started in order to ensure correct operation, based on the way the system was powered off, or
on the boot-time selection menu.
Run time
All Power Systems servers can monitor critical system components during run time, and they
can take corrective actions when recoverable faults occur. IBM hardware error-check
architecture provides the ability to report non-critical errors in an out-of-band communications
path to the service processor without affecting system performance.
A significant part of IBM runtime diagnostic capabilities originate with the service processor.
Extensive diagnostic and fault analysis routines have been developed and improved over
many generations of POWER processor-based servers, and enable quick and accurate
predefined responses to both actual and potential system problems.
148 IBM Power 720 and 740: Technical Overview and Introduction
The service processor correlates and processes runtime error information, using logic
derived from IBM engineering expertise to count recoverable errors (called thresholding) and
predict when corrective actions must be automatically initiated by the system. The following
actions are included:
Requests for a part to be replaced
Dynamic invocation of built-in redundancy for automatic replacement of a failing part
Dynamic deallocation of failing components so that system availability is maintained
Device drivers
In certain cases, diagnostics are best performed by operating system-specific drivers, most
notably, I/O devices that are owned directly by a logical partition. In these cases, the operating
system device driver often works in conjunction with the I/O device microcode to isolate and
recover from problems. Potential problems are reported to an operating system device driver,
which logs the error. I/O devices can also include specific exercisers that can be invoked by
the diagnostic facilities for problem recreation if required by service procedures.
4.3.3 Reporting
In the unlikely event that a system hardware or environmentally induced failure is diagnosed,
IBM Power Systems servers report the error through a number of mechanisms. The analysis
result is stored in system NVRAM. Error log analysis (ELA) can be used to display the failure
cause and the physical location of the failing hardware.
With the integrated service processor, the system has the ability to automatically send out an
alert through a phone line to a pager, or call for service in the event of a critical system failure.
A hardware fault also illuminates the amber system fault LED located on the system unit to
alert the user of an internal hardware problem.
On POWER7 processor-based servers, hardware and software failures are recorded in the
system log. When an HMC is attached, an ELA routine analyzes the error, forwards the event
to the Service Focal Point (SFP) application running on the HMC, and notifies the system
administrator that it has isolated a likely cause of the system problem. The service processor
event log also records unrecoverable checkstop conditions, forwards them to the SFP
application, and notifies the system administrator.
After the information is logged in the SFP application, if the system is properly configured,
a call-home service request is initiated and the pertinent failure data with service parts
information and part locations is sent to an IBM service organization. Client contact
information and specific system-related data such as the machine type, model, and serial
number, along with error log data related to the failure are sent to IBM Service.
Error logging and analysis
When the root cause of an error has been identified by a fault isolation component, an error
log entry is created with basic data such as the following examples:
An error code uniquely describing the error event
The location of the failing component
The part number of the component to be replaced, including pertinent data such as
engineering and manufacturing levels
Return codes
Resource identifiers
FFDC data
Chapter 4. Continuous availability and manageability 149
Data containing information about the effect that the repair will have on the system is also
included. Error log routines in the operating system can then use this information and decide
to call home to contact service and support, send a notification message, or continue without
an alert.
Remote support
The Remote Management and Control (RMC) application is delivered as part of the base
operating system, including the operating system running on the Hardware Management
Console. RMC provides a secure transport mechanism across the LAN interface between the
operating system and the Hardware Management Console and is used by the operating
system diagnostic application for transmitting error information. It performs a number of other
functions also, but these are not used for the service infrastructure.
Service Focal Point
A critical requirement in a logically partitioned environment is to ensure that errors are not lost
before being reported for service, and that an error must only be reported once, regardless of
how many logical partitions experience the potential effect of the error. The Manage
Serviceable Events task on the Hardware Management Console (HMC) is responsible for
aggregating duplicate error reports, and ensures that all errors are recorded for review and
management.
When a local or globally reported service request is made to the operating system, the
operating system diagnostic subsystem uses the Remote Management and Control
Subsystem (RMC) to relay error information to the Hardware Management Console. For
global events (platform unrecoverable errors, for example) the service processor will also
forward error notification of these events to the Hardware Management Console, providing a
redundant error-reporting path in case of errors in the RMC network.
The first occurrence of each failure type is recorded in the Manage Serviceable Events task
on the Hardware Management Console. This task then filters and maintains a history of
duplicate reports from other logical partitions on the service processor. It then looks at all
active service event requests, analyzes the failure to ascertain the root cause and, if enabled,
initiates a call home for service. This methodology ensures that all platform errors will be
reported through at least one functional path, ultimately resulting in a single notification for a
single problem.
Extended error data (EED)
Extended error data (EED) is additional data that is collected either automatically at the time
of a failure or manually at a later time. The data collected is dependent on the invocation
method but includes information such as firmware levels, operating system levels, additional
fault isolation register values, recoverable error threshold register values, system status, and
any other pertinent data.
The data is formatted and prepared for transmission back to IBM to assist the service support
organization with preparing a service action plan for the service representative or for
additional analysis.
System dump handling
In certain circumstances, an error might require a dump to be automatically or manually
created. In this event, it is off-loaded to the HMC upon the reboot. Specific HMC information is
included as part of the information that can optionally be sent to IBM support for analysis. If
additional information relating to the dump is required, or if it becomes necessary to view the
dump remotely, the HMC dump record notifies the IBM support center regarding on which
HMC the dump is located.
150 IBM Power 720 and 740: Technical Overview and Introduction
4.3.4 Notifying
After a Power Systems server has detected, diagnosed, and reported an error to an
appropriate aggregation point, it then takes steps to notify the client, and if necessary, the
IBM support organization. Depending upon the assessed severity of the error and support
agreement, this might range from a simple notification to having field service personnel
automatically dispatched to the client site with the correct replacement part.
Client Notify
When an event is important enough to report, but does not indicate the need for a repair
action or the need to call home to IBM service and support, it is classified as Client Notify.
Clients are notified because these events might be of interest to an administrator. The event
might be a symptom of an expected systemic change, such as a network reconfiguration or
failover testing of redundant power or cooling systems. Examples of these events include:
Network events such as the loss of contact over a local area network (LAN)
Environmental events such as ambient temperature warnings
Events that need further examination by the client (although these events do not
necessarily require a part replacement or repair action)
Client Notify events are serviceable events, by definition, because they indicate that
something has happened that requires client awareness in the event the client wants to take
further action. These events can always be reported back to IBM at the client’s discretion.
Call home
A correctly configured POWER processor-based system can initiate an automatic or manual
call from a client location to the IBM service and support organization with error data, server
status, or other service-related information. The call-home feature invokes the service
organization in order for the appropriate service action to begin, automatically opening a
problem report, and in certain cases, also dispatching field support. This automated reporting
provides faster and potentially more accurate transmittal of error information. Although
configuring call-home is optional, clients are strongly encouraged to configure this feature in
order to obtain the full value of IBM service enhancements.
Vital product data (VPD) and inventory management
Power Systems store vital product data (VPD) internally, which keeps a record of how much
memory is installed, how many processors are installed, manufacturing level of the parts, and
so on. These records provide valuable information that can be used by remote support and
service representatives, enabling them to provide assistance in keeping the firmware and
software on the server up-to-date.
IBM problem management database
At the IBM support center, historical problem data is entered into the IBM Service and
Support Problem Management database. All of the information that is related to the error,
along with any service actions taken by the service representative, are recorded for problem
management by the support and development organizations. The problem is then tracked
and monitored until the system fault is repaired.
4.3.5 Locating and servicing
The final component of a comprehensive design for serviceability is the ability to effectively
locate and replace parts requiring service. POWER processor-based systems use a
combination of visual cues and guided maintenance procedures to ensure that the identified
part is replaced correctly, every time.
Chapter 4. Continuous availability and manageability 151
Packaging for service
The following service enhancements are included in the physical packaging of the systems to
facilitate service:
Color coding (touch points):
– Terracotta-colored touch points indicate that a component (FRU or CRU) can be
concurrently maintained.
– Blue-colored touch points delineate components that are not concurrently maintained
(those that require the system to be turned off for removal or repair).
Tool-less design: Selected IBM systems support tool-less or simple tool designs. These
designs require no tools or simple tools such as flathead screw drivers to service the
hardware components.
Positive retention: Positive retention mechanisms help to assure proper connections
between hardware components, such as from cables to connectors, and between two
cards that attach to each other. Without positive retention, hardware components run the
risk of becoming loose during shipping or installation, preventing a good electrical
connection. Positive retention mechanisms such as latches, levers, thumb-screws, pop
Nylatches (U-clips), and cables are included to help prevent loose connections and aid in
installing (seating) parts correctly. These positive retention items do not require tools.
Light Path
The Light Path LED feature is supported by the Power 710, 720, 730, 740, 750, and the 755
servers. In the Light Path LED implementation, when a fault condition is detected on the
POWER7 processor-based system, an amber FRU fault LED is illuminated, which is then
rolled up to the system fault LED. The Light Path system pinpoints the exact part by turning on
the amber FRU fault LED that is associated with the part to be replaced.
The system can clearly identify components for replacement by using specific
component-level LEDs, and can also guide the servicer directly to the component by signaling
(staying on solid) the system fault LED, enclosure fault LED, and the component FRU fault
LED.
After the repair, the LEDs shut off automatically if the problem is fixed.
Guiding Light
The enclosure and system identify LEDs that turn on solid and that can be used to follow the
path from the system to the enclosure and down to the specific FRU.
Guiding Light uses a series of flashing LEDs, allowing a service provider to quickly and easily
identify the location of system components. Guiding Light can also handle multiple error
conditions simultaneously, which might be necessary in certain very complex high-end
configurations.
In these situations, Guiding Light waits for the servicer’s indication of what failure to attend
first and then illuminates the LEDs to the failing component.
Data centers can be complex places, and Guiding Light is designed to do more than identify
visible components. When a component might be hidden from view, Guiding Light can flash a
sequence of LEDs that extend to the frame exterior, clearly guiding the service representative
to the correct rack, system, enclosure, drawer, and component.
152 IBM Power 720 and 740: Technical Overview and Introduction
Service labels
Service providers use these labels to assist them in performing maintenance actions. Service
labels are found in various formats and positions, and are intended to transmit readily
available information to the servicer during the repair process.
Various service labels and the purpose of each are described in the following list:
Location diagrams are strategically located on the system hardware, relating information
regarding the placement of hardware components. Location diagrams can include location
codes, drawings of physical locations, concurrent maintenance status, or other data that is
pertinent to a repair. Location diagrams are especially useful when multiple components
are installed such as DIMMs, CPUs, processor books, fans, adapter cards, LEDs, and
power supplies.
Remove or replace procedure labels contain procedures often found on a cover of the
system or in other spots that are accessible to the servicer. These labels provide
systematic procedures, including diagrams, detailing how to remove and replace certain
serviceable hardware components.
Numbered arrows are used to indicate the order of operation and serviceability direction of
components. Various serviceable parts such as latches, levers, and touch points must be
pulled or pushed in a certain direction and certain order so that the mechanical
mechanisms can engage or disengage. Arrows generally improve the ease of
serviceability.
The operator panel
The operator panel on a Power 720 and Power 740 is a four-row by 16-element LCD display
that is used to present boot progress codes, indicating advancement through the system
power-on and initialization processes. The operator panel is also used to display error and
location codes when an error occurs that prevents the system from booting. It includes
various buttons, enabling a service support representative or client to change various
boot-time options and f other limited service functions.
Concurrent maintenance
The IBM POWER7 processor-based systems are designed with the understanding that
certain components have higher intrinsic failure rates than others. The movement of fans,
power supplies, and physical storage devices naturally make them more susceptible to
wearing down or burning out; other devices such as I/O adapters can begin to wear from
repeated plugging and unplugging. For these reasons, these devices have been specifically
designed to be concurrently maintainable, when properly configured.
In other cases, a client might be in the process of moving or redesigning a data center, or
planning a major upgrade. At times like these, flexibility is crucial. The IBM POWER7
processor-based systems are designed for redundant or concurrently maintainable power,
fans, physical storage, and I/O towers.
The most recent members of the IBM Power Systems family, based on the POWER7
processor, continue to support concurrent maintenance of power, cooling, media devices, I/O
drawers, GX adapter, and the operator panel. In addition, they support concurrent firmware
fixpack updates when possible. The determination of whether a firmware fixpack release can
be updated concurrently is identified in the readme file that is released with the firmware.
Firmware updates
Firmware updates for Power Systems are released in a cumulative sequential fix format,
packaged as an RPM for concurrent application and activation. Administrators can install and
activate many firmware patches without cycling power or rebooting the server.
Chapter 4. Continuous availability and manageability 153
When an HMC is connected to the system, the new firmware image is loaded using any of the
following methods:
IBM distributed media, such as a CD-ROM
A Problem Fix distribution from the IBM Service and Support repository
FTP from another server
Download from the IBM Fix Central website:
http://www.ibm.com/support/fixcentral/
IBM supports multiple firmware releases in the field. Therefore, under expected
circumstances, a server can operate on an existing firmware release, using concurrent
firmware fixes to stay up-to-date with the current patch level. Because changes to various
server functions (for example, changing initialization values for chip controls) cannot occur
during system operation, a patch in this area requires a system reboot for activation. Under
normal operating conditions, IBM provides patches for an individual firmware release level for
up to two years after first making the release code generally available. After this period,
clients must plan to update in order to stay on a supported firmware release.
Activation of new firmware functions, as opposed to patches, require installation of a new
firmware release level. This process is disruptive to server operations because it requires a
scheduled outage and full server reboot.
In addition to concurrent and disruptive firmware updates, IBM also offers concurrent
patches, which include functions that are not activated until a subsequent server reboot.
A server with these patches can operate normally. The additional concurrent fixes can be
installed and activated when the system reboots after the next scheduled outage.
Additional capability is being added to the firmware to be able to view the status of a system
power control network background firmware update. This subsystem can update as
necessary, as migrated nodes or I/O drawers are added to the configuration. The new
firmware provides an interface to be able to view the progress of the update, and also control
starting and stopping of the background update if a more convenient time becomes available.
Repair and verify
Repair and verify (R&V) is a system used to guide a service provider step-by-step through the
process of repairing a system and verifying that the problem has been repaired. The steps
are customized in the appropriate sequence for the particular repair for the specific system
being repaired. Repair scenarios covered by repair and verify include:
Replacing a defective field-replaceable unit (FRU)
Reattaching a loose or disconnected component
Correcting a configuration error
Removing or replacing an incompatible FRU
Updating firmware, device drivers, operating systems, middleware components, and IBM
applications after replacing a part
Installing a new part
Repair and verify procedures can be used by both service representative providers who are
familiar with the task and those who are not. Education On Demand content is placed in the
procedure at the appropriate locations. Throughout the repair and verify procedure, repair
history is collected and provided to the Service and Support Problem Management Database
for storage with the serviceable event, to ensure that the guided maintenance procedures are
operating correctly.
154 IBM Power 720 and 740: Technical Overview and Introduction
Clients can subscribe through the subscription services to obtain the notifications about the
latest updates available for service-related documentation. The latest version of the
documentation is accessible through the Internet; a CD-ROM version is also available.
4.4 Manageability
Several functions and tools help manageability, and enable you to efficiently and effectively
manage your system.
4.4.1 Service user interfaces
The Service Interface allows support personnel or the client to communicate with the service
support applications in a server using a console, interface, or terminal. Delivering a clear,
concise view of available service applications, the Service Interface allows the support team
to manage system resources and service information in an efficient and effective way.
Applications available through the Service Interface are carefully configured and placed to
give service providers access to important service functions.
Various service interfaces are used, depending on the state of the system and its operating
environment. The primary service interfaces are:
Light Path and Guiding Light
For more information, see “Light Path” on page 151 and “Guiding Light” on page 151.
Service processor; Advanced System Management Interface (ASMI)
Operator panel
Operating system service menu
Service Focal Point on the Hardware Management Console
Service Focal Point Lite on Integrated Virtualization Manager
Service processor
The service processor is a controller that is running its own operating system. It is a
component of the service interface card.
The service processor operating system has specific programs and device drivers for the
service processor hardware. The host interface is a processor support interface that is
connected to the POWER processor. The service processor is always working, regardless of
main system unit’s state. The system unit can be in the following states:
Standby (power off)
Operating, ready to start partitions
Operating with running logical partitions
Functions
The service processor is used to monitor and manage the system hardware resources and
devices. The service processor checks the system for errors, ensuring the connection to the
HMC for manageability purposes and accepting Advanced System Management Interface
(ASMI) Secure Sockets Layer (SSL) network connections. The service processor provides
the ability to view and manage the machine-wide settings by using the ASMI, and enables
complete system and partition management from the HMC.
Chapter 4. Continuous availability and manageability 155
The service processor uses two Ethernet 10/100Mbps ports. Note the following information:
Both Ethernet ports are only visible to the service processor and can be used to attach the
server to an HMC or to access the ASMI. The ASMI options can be accessed through an
HTTP server that is integrated into the service processor operating environment.
Both Ethernet ports support only auto-negotiation. Customer selectable media speed and
duplex settings are not available.
Both Ethernet ports have a default IP address, as follows:
– Service processor Eth0 or HMC1 port is configured as 169.254.2.147
– Service processor Eth1 or HMC2 port is configured as 169.254.3.147
The functions available through service processor include:
Call Home
Advanced System Management Interface (ASMI)
Error Information (error code, PN, Location Codes) menu
View of guarded components
Limited repair procedures
Generate dump
LED Management menu
Remote view of ASMI menus
Firmware update through USB key
Advanced System Management Interface (ASMI)
ASMI is the interface to the service processor that enables you to manage the operation of
the server, such as auto-power restart, and to view information about the server, such as the
error log and vital product data. Various repair procedures require connection to the ASMI.
The ASMI is accessible through the HMC. It is also accessible by using a web browser on a
system that is connected directly to the service processor (in this case, either a standard
Ethernet cable or a crossed cable) or through an Ethernet network. ASMI can also be
accessed from an ASCII terminal. Use the ASMI to change the service processor IP
addresses or to apply certain security policies and prevent access from undesired IP
addresses or ranges.
You might be able to use the service processor’s default settings. In that case, accessing the
ASMI is not necessary.
To access ASMI, use one of the following steps:
Access the ASMI by using an HMC.
If configured to do so, the HMC connects directly to the ASMI for a selected system from
this task.
To connect to the Advanced System Management interface from an HMC, follow these
steps:
a. Open Systems Management from the navigation pane.
b. From the work pane, select one or more managed systems to work with.
c. From the System Management tasks list, select Operations Advanced System
Management (ASM).
Note: The service processor enables a system that does not boot to be analyzed. The
error log analysis can be performed from either the ASMI or the HMC.
156 IBM Power 720 and 740: Technical Overview and Introduction
Access the ASMI by using a web browser.
The web interface to the ASMI is accessible through Microsoft® Internet Explorer 6.0,
Microsoft Internet Explorer 7, Netscape 7.1, Mozilla Firefox, or Opera 7.23 running on a
PC or mobile computer that is connected to the service processor. The web interface is
available during all phases of system operation, including the initial program load (IPL)
and run time.
However, a few of the menu options in the web interface are unavailable during IPL or run
time to prevent usage or ownership conflicts if the system resources are in use during that
phase. The ASMI provides a Secure Sockets Layer (SSL) web connection to the service
processor. To establish an SSL connection, open your browser using the address:
https://<ip_address_of_service_processor>
(where <ip_address_of_service_processor> is the address of the service processor of
your Power Systems server, such as 9.166.196.7).
Access the ASMI using an ASCII terminal.
The ASMI on an ASCII terminal supports a subset of the functions that are provided by the
web interface and is available only when the system is in the platform standby state. The
ASMI on an ASCII console is not available during various phases of system operation,
such as the IPL and run time.
The operator panel
The service processor provides an interface to the operator panel, which is used to display
system status and diagnostic information.
The operator panel can be accessed in two ways:
By using the normal operational front view
By pulling it out to access the switches and view the LCD display. Figure 4-6 on page 157
shows that the operator panel on a Power 720 and 740 is pulled out.
Note: To make the connection through Internet Explorer, click Tools Internet Options.
Clear the Use TLS 1.0 check box, and click OK.
Chapter 4. Continuous availability and manageability 157
Figure 4-6 Operator panel is pulled out from the chassis
The operator panel includes features such as these:
A 2 x 16 character LCD display
Reset, enter, power On/Off, increment and decrement buttons
Amber System Information/Attention, green Power LED
Blue Enclosure Identify LED on the Power 720 and 740
Altitude sensor
USB Port
Speaker/Beeper
The following functions are available through the operator panel:
Error Information
Generate dump
View Machine Type, Model and Serial Number
Limited set of repair functions
Operating system service menu
The system diagnostics consist of IBM i service tools, stand-alone diagnostics that are loaded
from the DVD drive, and online diagnostics (available in AIX).
Online diagnostics, when installed, are a part of the AIX or IBM i operating system on the disk
or server. They can be booted in single-user mode (service mode), run in maintenance mode,
or run concurrently (concurrent mode) with other applications. They have access to the AIX
error log and the AIX configuration data. IBM i has a service tools problem log, IBM i history
log (QHST), and IBM i problem log.
Release Lever
(slide left to release operator panel and pull out from chassis)
158 IBM Power 720 and 740: Technical Overview and Introduction
The available modes are as follows:
Service mode:
Requires a service mode boot of the system, enables the checking of system devices and
features. Service mode provides the most complete checkout of the system resources. All
system resources, except the SCSI adapter and the disk drives used for paging, can be
tested.
Concurrent mode:
Enables the normal system functions to continue while selected resources are being
checked. Because the system is running in normal operation, certain devices might
require additional actions by the user or diagnostic application before testing can be done.
Maintenance mode:
Enables the checking of most system resources. Maintenance mode provides the same
test coverage as service mode. The difference between the two modes is the way they are
invoked. Maintenance mode requires that all activity on the operating system be stopped.
The shutdown -m command is used to stop all activity on the operating system and put the
operating system into maintenance mode.
The System Management Services (SMS) error log is accessible on the SMS menus. This
error log contains errors that are found by partition firmware when the system or partition is
booting.
You can access the service processor’s error log on the ASMI menus.
You can also access the system diagnostics from an AIX Network Installation Management
(NIM) server.
The IBM i operating system and associated machine code provide Dedicated Service Tools
(DST) as part of the IBM i licensed machine code (Licensed Internal Code) and System
Service Tools (SST) as part of the IBM i operating system. DST can be run in dedicated mode
(no operating system loaded). DST tools and diagnostics are a superset of those available
under SST.
The IBM i End Subsystem (ENDSBS *ALL) command can shut down all IBM and customer
applications subsystems except the controlling subsystem QTCL. The Power Down System
(PWRDWNSYS) command can be set to power down the IBM i partition and restart the
partition in DST mode.
You can start SST during normal operations, which leaves all applications up and running,
using the IBM i Start Service Tools (STRSST) command (when signed onto IBM i with the
appropriately secured user ID).
With DST and SST, you can look at various logs, run various diagnostics, or take various
kinds of system dumps or other options.
Depending on the operating system, the service-level functions that you typically see when
using the operating system service menus are as follows:
Product activity log
Trace Licensed Internal Code
Work with communications trace
Note: When your order a Power System, a DVD-ROM or DVD-RAM might be optional. An
alternate method for maintaining and servicing the system must be available if you do not
order the DVD-ROM or DVD-RAM.
Chapter 4. Continuous availability and manageability 159
Display/Alter/Dump
Licensed Internal Code log
Main storage dump manager
Hardware service manager
Call Home/Customer Notification
Error information menu
LED management menu
Concurrent/Non-concurrent maintenance (within scope of the OS)
Managing firmware levels
– Server
– Adapter
Remote support (access varies by OS)
Service Focal Point on the Hardware Management Console
Service strategies become more complicated in a partitioned environment. The Manage
Serviceable Events task in the HMC can help to streamline this process.
Each logical partition reports errors that it detects and forwards the event to the Service Focal
Point (SFP) application that is running on the HMC, without determining whether other logical
partitions also detect and report the errors. For example, if one logical partition reports an
error for a shared resource, such as a managed system power supply, other active logical
partitions might report the same error.
By using the Manage Serviceable Events task in the HMC, you can avoid long lists of
repetitive call-home information by recognizing that these are repeated errors and
consolidating them into one error.
In addition, you can use the Manage Serviceable Events task to initiate service functions on
systems and logical partitions, including the exchanging of parts, configuring connectivity, and
managing dumps.
The following functions are available through the Service Focal Point on the Hardware
Management Console:
Service Focal Point:
– Managing serviceable events and service data
– Managing service indicators
Error Information:
– OS Diagnostic
– Service Processor
– Service Focal Point
LED Management menu
Serviceable events analysis
Repair and Verify:
– Concurrent Maintenance
– Deferred Maintenance
– Immediate Maintenance
Hot-Node Add, Hot-Node Repair, and Memory Upgrade
FRU Replacement
Managing firmware levels:
– HMC
160 IBM Power 720 and 740: Technical Overview and Introduction
– Server
– Adapter
– Concurrent Firmware updates
Call Home/Customer Notification
Virtualization
I/O Topology view
Generate dump
Remote support (full access)
Virtual operator panel
Service Focal Point Lite on the Integrated Virtualization Manager
The following functions are available through the Service Focal Point Lite on the Integrated
Virtualization Manager:
Service Focal Point-Lite:
– Managing serviceable events and service data
– Managing service indicators
Call Home/Customer Notification (both not available yet)
Error Information menu:
– OS Diagnostic
– Service Focal Point lite
LED Management menu
Managing firmware levels:
– Server
– Adapter
Virtualization
Generate dump (limited capability)
Remote support (limited access)
4.4.2 IBM Power Systems firmware maintenance
The IBM Power Systems Client-Managed Microcode is a methodology that enables you to
manage and install microcode updates on Power Systems and associated I/O adapters.
The system firmware consists of service processor microcode, Open Firmware microcode,
SPCN microcode, and the POWER Hypervisor.
The firmware and microcode can be downloaded and installed either from an HMC, from a
running partition, or from USB port number one on the rear of a Power 720 and 740, if that
system is not managed by an HMC.
Power Systems has a permanent firmware boot side, or A side, and a temporary firmware
boot side, or B side. New levels of firmware must be installed on the temporary side first in
order to test the update’s compatibility with existing applications. When the new level of
firmware has been approved, it can be copied to the permanent side.
Chapter 4. Continuous availability and manageability 161
For access to the initial web pages that address this capability, see Support for IBM Systems
web page:
http://www.ibm.com/systems/support
For Power Systems, select the Power link. Figure 4-7 shows an example.
Figure 4-7 Support for Power servers web page
Although the content under the Popular links section can change, click the Firmware and
HMC updates link to go to the resources for keeping your system’s firmware current.
162 IBM Power 720 and 740: Technical Overview and Introduction
If there is an HMC to manage the server, the HMC interface can be use to view the levels of
server firmware and power subsystem firmware that are installed and are available to
download and install.
Each IBM Power Systems server has the following levels of server firmware and power
subsystem firmware:
Installed level:
This level of server firmware or power subsystem firmware has been installed and will be
installed into memory after the managed system is powered off and then powered on. It is
installed on the temporary side of system firmware.
Activated level:
This level of server firmware or power subsystem firmware is active and running in
memory.
Accepted level:
This level is the backup level of server or power subsystem firmware. You can return to this
level of server or power subsystem firmware if you decide to remove the installed level. It is
installed on the permanent side of system firmware.
IBM provides the Concurrent Firmware Maintenance (CFM) function on selected Power
Systems. This function supports applying nondisruptive system firmware service packs to the
system concurrently (without requiring a reboot operation to activate changes). For systems
that are not managed by an HMC, the installation of system firmware is always disruptive.
The concurrent levels of system firmware can, on occasion, contain fixes that are known as
deferred. These deferred fixes can be installed concurrently but are not activated until the
next IPL. Deferred fixes, if any, will be identified in the “Firmware Update Descriptions” table of
the firmware document. For deferred fixes within a service pack, only the fixes in the service
pack that cannot be concurrently activated are deferred. Table 4-1 shows the file-naming
convention for system firmware.
Table 4-1 Firmware naming convention
PPNNSSS_FFF_DDD
PP Package identifier 01 -
02 -
NN Platform & Class AL Low End
AM Mid Range
AS Blade Server
AH High End
AP Bulk Power for IH
AB Bulk Power for High
End
SSS Release indicator
FFF Current fixpack
DDD Last disruptive fixpack
Chapter 4. Continuous availability and manageability 163
The following example uses the convention:
01AL710_086 = POWER7 Entry Systems Firmware for 8233-E8B and 8236-E8B
An installation is disruptive if the following statements are true:
The release levels (SSS) of currently installed and new firmware differ.
The service pack level (FFF) and the last disruptive service pack level (DDD) are equal in
new firmware.
Otherwise, an installation is concurrent if the service pack level (FFF) of the new firmware is
higher than the service pack level currently installed on the system and the conditions for
disruptive installation are not met.
4.4.3 Electronic Services and Electronic Service Agent
IBM has transformed its delivery of hardware and software support services to help you
achieve higher system availability. Electronic Services is a web-enabled solution that offers an
exclusive, no-additional-charge enhancement to the service and support available for IBM
servers. These services provide the opportunity for greater system availability with faster
problem resolution and preemptive monitoring. The Electronic Services solution consists of
two separate, but complementary, elements:
Electronic Services news page
The Electronic Services news page is a single Internet entry point that replaces the
multiple entry points that are traditionally used to access IBM Internet services and
support. The news page enables you to gain easier access to IBM resources for
assistance in resolving technical problems.
IBM Electronic Service Agent™
The Electronic Service Agent is software that resides on your server. It monitors events
and transmits system inventory information to IBM on a periodic, client-defined timetable.
The Electronic Service Agent automatically reports hardware problems to IBM.
Early knowledge about potential problems enables IBM to deliver proactive service that can
result in higher system availability and performance. In addition, information that is collected
through the Service Agent is made available to IBM service support representatives when
they help answer your questions or diagnose problems. Installation and use of IBM Electronic
Service Agent for problem reporting enables IBM to provide better support and service for
your IBM server.
To learn how Electronic Services can work for you, visit:
https://www.ibm.com/support/electronic/portal
164 IBM Power 720 and 740: Technical Overview and Introduction
4.5 Operating system support for RAS features
Table 4-2 provides an overview of a number of features for continuous availability that are
supported by the various operating systems running on the POWER7 processor-based
systems.
Table 4-2 Operating system support for RAS features
RAS feature
AIX
5.3
AIX
6.1
AIX
7.1
IBM i
6.1.1
IBM i
7.1
RHEL 5 SLES
10
SP 3
SLES
11
SP 1
System deallocation of failing components
Dynamic Processor Deallocation        
Dynamic Processor Sparing        
Processor Instruction Retry        
Alternate Processor Recovery        
Partition Contained Checkstop        
Persistent processor deallocation        
GX++ bus persistent deallocation      - - 
PCI bus extended error detection        
PCI bus extended error recovery
     Most
Mos
t
Mos
t
PCI-PCI bridge extended error handling      - - -
Redundant RIO or 12x Channel link        
PCI card hot-swap        
Dynamic SP failover at run-time        
Memory sparing with CoD at IPL time        
Clock failover runtime or IPL        
Memory availability
64-byte ECC code        
Hardware scrubbing        
CRC        
Chipkill        
L1 instruction and data array protection        
L2/L3 ECC & cache line delete        
Special uncorrectable error handling        
Fault detection and isolation
Platform FFDC diagnostics        
Run-time diagnostics
     Most
Mos
t
Mos
t
Chapter 4. Continuous availability and manageability 165
Storage Protection Keys -     - - -
Dynamic Trace      - - 
Operating System FFDC -     - - -
Error log analysis        
Service Processor support for:
Built-in-Self-Tests (BIST) for logic and arrays        
Wire tests        
Component initialization        
Serviceability
Boot-time progress indicators      Most
Mos
t
Mos
t
Firmware error codes        
Operating system error codes      Most
Mos
t
Mos
t
Inventory collection        
Environmental and power warnings        
Hot-plug fans, power supplies        
Extended error data collection        
SP “call home” on non-HMC configurations        
I/O drawer redundant connections        
I/O drawer hot add and concurrent repair        
Concurrent RIO/GX adapter add        
Concurrent cold-repair of GX adapter        
Concurrent add of powered I/O rack to Power 795        
SP mutual surveillance w/ POWER Hypervisor        
Dynamic firmware update with HMC        
Service Agent Call Home Application        
Guiding light LEDs        
Lightpath LEDs        
System dump for memory, POWER Hypervisor, SP        
Infocenter / Systems Support Site service publications        
System Support Site education        
Operating system error reporting to HMC SFP        
RMC secure error transmission subsystem        
RAS feature
AIX
5.3
AIX
6.1
AIX
7.1
IBM i
6.1.1
IBM i
7.1
RHEL 5 SLES
10
SP 3
SLES
11
SP 1
166 IBM Power 720 and 740: Technical Overview and Introduction
Health check scheduled operations with HMC        
Operator panel (real or virtual)        
Concurrent operator panel maintenance        
Redundant HMCs        
Automated server recovery/restart        
High availability clustering support        
Repair and Verify Guided Maintenance      Most
Mos
t
Mos
t
Concurrent kernel update -     - - -
RAS feature
AIX
5.3
AIX
6.1
AIX
7.1
IBM i
6.1.1
IBM i
7.1
RHEL 5 SLES
10
SP 3
SLES
11
SP 1
© Copyright IBM Corp. 2010. All rights reserved. 167
Related publications
The publications listed in this section are considered particularly suitable for a more detailed
discussion of the topics covered in this paper.
IBM Redbooks
For information about ordering these publications, see “How to get Redbooks publications” on
page 169. Note that some of the documents referenced here might be available in softcopy
only.
IBM Power 710 and 730 Technical Overview and Introduction, REDP-4637
IBM Power 795 Technical Overview and Introduction, REDP-4640
PowerVM Virtualization on IBM System p: Introduction and Configuration Fourth Edition,
SG24-7940
IBM PowerVM Virtualization Managing and Monitoring, SG24-7590
IBM PowerVM Live Partition Mobility, SG24-7460
IBM System p Advanced POWER Virtualization (PowerVM) Best Practices, REDP-4194
PowerVM Migration from Physical to Virtual Storage, SG24-7825
IBM System Storage DS8000: Copy Services in Open Environments, SG24-6788
IBM System Storage DS8700 Architecture and Implementation, SG24-8786
PowerVM and SAN Copy Services, REDP-4610
SAN Volume Controller V4.3.0 Advanced Copy Services, SG24-7574
Other publications
These publications are also relevant as further information sources:
IBM Power Systems Facts and Features POWER7 Blades and Servers:
ftp://public.dhe.ibm.com/common/ssi/ecm/en/pob03022usen/POB03022USEN.PDF
PCI adapter placement for the 8202-E4B or 8205-E6B:
http://publib.boulder.ibm.com/infocenter/powersys/v3r1m5/topic/p7eab/p7eab_72x_
74x.pdf
Specific storage devices supported for Virtual I/O Server, see:
http://www14.software.ibm.com/webapp/set2/sas/f/vios/documentation/datasheet.ht
ml
IBM Power 710 server Data Sheet:
ftp://public.dhe.ibm.com/common/ssi/ecm/en/pod03048usen/POD03048USEN.PDF
IBM Power 720 server Data Sheet:
ftp://public.dhe.ibm.com/common/ssi/ecm/en/pod03049usen/POD03049USEN.PDF
168 IBM Power 720 and 740: Technical Overview and Introduction
IBM Power 730 server Data Sheet:
ftp://public.dhe.ibm.com/common/ssi/ecm/en/pod03050usen/POD03050USEN.PDF
IBM Power 740 server Data Sheet:
ftp://public.dhe.ibm.com/common/ssi/ecm/en/pod03051usen/POD03051USEN.PDF
IBM Power 750 server Data Sheet:
http://www.ibm.com/common/ssi/fcgi-bin/ssialias?infotype=PM&subtype=SP&appname=
STGE_PO_PO_USEN&htmlfid=POD03034USEN&attachment=POD03034USEN.PDF
IBM Power 755 server Data Sheet:
http://www.ibm.com/common/ssi/fcgi-bin/ssialias?infotype=PM&subtype=SP&appname=
STGE_PO_PO_USEN&htmlfid=POD03035USEN&attachment=POD03035USEN.PDF
IBM Power 770 server Data Sheet:
http://www.ibm.com/common/ssi/fcgi-bin/ssialias?infotype=PM&subtype=SP&appname=
STGE_PO_PO_USEN&htmlfid=POD03031USEN&attachment=POD03031USEN.PDF
IBM Power 780 server Data Sheet:
http://www.ibm.com/common/ssi/fcgi-bin/ssialias?infotype=PM&subtype=SP&appname=
STGE_PO_PO_USEN&htmlfid=POD03032USEN&attachment=POD03032USEN.PDF
IBM Power 795 server Data Sheet:
ftp://public.dhe.ibm.com/common/ssi/ecm/en/pod03053usen/POD03053USEN.PDF
Active Memory Expansion: Overview and Usage Guide:
http://www-03.ibm.com/systems/power/hardware/whitepapers/am_exp.html
Migration combinations of processor compatibility modes for active Partition Mobility:
http://publib.boulder.ibm.com/infocenter/powersys/v3r1m5/topic/p7hc3/iphc3pcmco
mbosact.htm
Advance Toolchain for Linux website:
http://www.ibm.com/developerworks/wikis/display/hpccentral/How+to+use+Advance+T
oolchain+for+Linux+on+POWER
Online resources
These websites are also relevant as further information sources:
IBM Power Systems Hardware Information Center at:
http://publib.boulder.ibm.com/infocenter/systems/scope/hw/index.jsp
IBM System Planning Tool site at:
http://www.ibm.com/systems/support/tools/systemplanningtool/
Download from the IBM Fix Central website:
http://www.ibm.com/support/fixcentral/
Power Systems Capacity on Demand website:
http://www.ibm.com/systems/power/hardware/cod/
Support for IBM Systems website:
http://www.ibm.com/systems/support
IBM Electronic Services portal:
https://www.ibm.com/support/electronic/portal
Related publications 169
IBM Storage website:
http://www.ibm.com/systems/storage/
How to get Redbooks publications
You can search for, view, or download Redbooks publications, Redpapers publications,
Technotes, draft publications and Additional materials, as well as order hardcopy Redbooks
publications, at this website:
ibm.com/redbooks
Help from IBM
IBM Support and downloads:
ibm.com/support
IBM Global Services:
ibm.com/services
170 IBM Power 720 and 740: Technical Overview and Introduction
Redbook overview and introduction 8670-61x
®
REDP-4637-00
INTERNATIONAL
TECHNICAL
SUPPORT
ORGANIZATION
BUILDING TECHNICAL
INFORMATION BASED ON
PRACTICAL EXPERIENCE
IBM Redbooks are developed
by the IBM International
Technical Support
Organization. Experts from
IBM, Customers and Partners
from around the world create
timely technical information
based on realistic scenarios.
Specific recommendations
are provided to help you
implement IT solutions more
effectively in your
environment.
For more information:
ibm.com/redbooks
Redpaper™
IBM Power 720 and 740
Technical Overview and Introduction
Features the POWER7
processor providing
advanced multi-core
technology
Reduced power
requirements with
power-saving
functions
Describes leading
midrange
performance
This IBM Redpaper publication is a comprehensive guide covering the
IBM Power 720 and Power 740 servers supporting AIX, IBM i, and
Linux operating systems. The goal of this paper is to introduce the
major innovative Power 720 and 740 offerings and their prominent
functions, including these:
The POWER7 processor available at frequencies of 3.0 GHz,
3.3 GHz, 3.55 GHz, and 3.7 GHz
The specialized POWER7 Level 3 cache that provides greater
bandwidth, capacity, and reliability
The 1 Gb or 10 Gb Integrated Virtual Ethernet adapter, included
with each server configuration, and providing native hardware
virtualization
PowerVM virtualization including PowerVM Live Partition Mobility
and PowerVM Active Memory Sharing
Active Memory Expansion that provides more usable memory than
what is physically installed on the system
EnergyScale technology that provides features such as power
trending, power-saving, capping of power, and thermal
measurement
Professionals who want to acquire a better understanding of IBM
Power Systems products can benefit from reading this paper.
This paper expands the current set of IBM Power Systems
documentation by providing a desktop reference that offers a detailed
technical description of the Power 720 and Power 740 systems.
This paper does not replace the latest marketing materials and
configuration tools. It is intended as an additional source of information
that, together with existing sources, can be used to enhance your
knowledge of IBM server solutions.
Back cover

More Related Content

PDF
Learn about IBM Power 720 and 740 Technical Overview and Introduction.
PDF
IBM Power 750 and 755 Technical Overview and Introduction
PDF
IBM Power 750 and 760 Technical Overview and Introduction
PDF
IBM Power 770 and 780 Technical Overview and Introduction
PDF
IBM Power 710 and 730 Technical Overview and Introduction
PDF
IBM Power 770 and 780 Technical Overview and Introduction
PDF
IBM zEnterprise 114 Technical Guide
PDF
IBM Flex System p260 and p460 Planning and Implementation Guide
Learn about IBM Power 720 and 740 Technical Overview and Introduction.
IBM Power 750 and 755 Technical Overview and Introduction
IBM Power 750 and 760 Technical Overview and Introduction
IBM Power 770 and 780 Technical Overview and Introduction
IBM Power 710 and 730 Technical Overview and Introduction
IBM Power 770 and 780 Technical Overview and Introduction
IBM zEnterprise 114 Technical Guide
IBM Flex System p260 and p460 Planning and Implementation Guide

What's hot (19)

PDF
IBM eX5 Portfolio Overview IBM System x3850 X5, x3950 X5, x3690 X5, and Blade...
PDF
IBM Flex System Interoperability Guide
PDF
Db2 virtualization
PDF
Implementing the ibm storwize v3700
PDF
Sg248107 Implementing the IBM Storwize V3700
PDF
IBM PureFlex System and IBM Flex System Products and Technology
PDF
Implementing IBM SmartCloud Entry on IBM PureFlex System
PDF
Integrating ibm db2 with the ibm system storage n series sg247329
PDF
Redbook: Running IBM WebSphere Application Server on System p and AIX: Optimi...
PDF
Os linux complete notes
PDF
Ibm power vc version 1.2.3 introduction and configuration
PDF
Virtual box documentação tecnica
PDF
Php myadmin documentation
PDF
Virtual box usermanual
PDF
Oracle VM VirtualBox User Manual
PDF
Ibm midrange system storage hardware guide sg247676
PDF
IBMRedbook
PDF
Db2 udb backup and recovery with ess copy services
PDF
JM White
IBM eX5 Portfolio Overview IBM System x3850 X5, x3950 X5, x3690 X5, and Blade...
IBM Flex System Interoperability Guide
Db2 virtualization
Implementing the ibm storwize v3700
Sg248107 Implementing the IBM Storwize V3700
IBM PureFlex System and IBM Flex System Products and Technology
Implementing IBM SmartCloud Entry on IBM PureFlex System
Integrating ibm db2 with the ibm system storage n series sg247329
Redbook: Running IBM WebSphere Application Server on System p and AIX: Optimi...
Os linux complete notes
Ibm power vc version 1.2.3 introduction and configuration
Virtual box documentação tecnica
Php myadmin documentation
Virtual box usermanual
Oracle VM VirtualBox User Manual
Ibm midrange system storage hardware guide sg247676
IBMRedbook
Db2 udb backup and recovery with ess copy services
JM White
Ad

Similar to Redbook overview and introduction 8670-61x (20)

PDF
redp5222.pdf
PDF
Ibm power systems e870 and e880 technical overview and introduction
PDF
IBM Power10.pdf
PDF
Introducing and Implementing IBM FlashSystem V9000
PDF
Ibm system storage solutions handbook
PDF
IBM BladeCenter Products and Technology
PDF
IBM PowerVC Introduction and Configuration
PDF
IBM PowerVM Virtualization Introduction and Configuration
PDF
IBM PowerVM Best Practices
PDF
IBM Flex System Networking in an Enterprise Data Center
PDF
IBM Flex System Interoperability Guide
PDF
Integrating ibm db2 with the ibm system storage n series sg247329
PDF
Tape automation with ibm e server xseries servers redp0415
PDF
AIX 5L Differences Guide Version 5.3 Edition
PDF
Ref arch for ve sg248155
PDF
Windows Internals Part 2_6th Edition.pdf
PDF
DB2 10 for Linux on System z Using z/VM v6.2, Single System Image Clusters an...
PDF
Nsr Userguide
PDF
Implementing Systems Management of IBM PureFlex System
PDF
Gdfs sg246374
redp5222.pdf
Ibm power systems e870 and e880 technical overview and introduction
IBM Power10.pdf
Introducing and Implementing IBM FlashSystem V9000
Ibm system storage solutions handbook
IBM BladeCenter Products and Technology
IBM PowerVC Introduction and Configuration
IBM PowerVM Virtualization Introduction and Configuration
IBM PowerVM Best Practices
IBM Flex System Networking in an Enterprise Data Center
IBM Flex System Interoperability Guide
Integrating ibm db2 with the ibm system storage n series sg247329
Tape automation with ibm e server xseries servers redp0415
AIX 5L Differences Guide Version 5.3 Edition
Ref arch for ve sg248155
Windows Internals Part 2_6th Edition.pdf
DB2 10 for Linux on System z Using z/VM v6.2, Single System Image Clusters an...
Nsr Userguide
Implementing Systems Management of IBM PureFlex System
Gdfs sg246374
Ad

Recently uploaded (20)

PDF
Approach and Philosophy of On baking technology
PDF
KodekX | Application Modernization Development
PPTX
Effective Security Operations Center (SOC) A Modern, Strategic, and Threat-In...
PDF
Agricultural_Statistics_at_a_Glance_2022_0.pdf
PDF
Per capita expenditure prediction using model stacking based on satellite ima...
PDF
Reach Out and Touch Someone: Haptics and Empathic Computing
PDF
Electronic commerce courselecture one. Pdf
PPTX
Spectroscopy.pptx food analysis technology
PDF
Diabetes mellitus diagnosis method based random forest with bat algorithm
PDF
Mobile App Security Testing_ A Comprehensive Guide.pdf
PDF
How UI/UX Design Impacts User Retention in Mobile Apps.pdf
PDF
Dropbox Q2 2025 Financial Results & Investor Presentation
PPTX
MYSQL Presentation for SQL database connectivity
PPTX
VMware vSphere Foundation How to Sell Presentation-Ver1.4-2-14-2024.pptx
PDF
Network Security Unit 5.pdf for BCA BBA.
PDF
Architecting across the Boundaries of two Complex Domains - Healthcare & Tech...
PPTX
20250228 LYD VKU AI Blended-Learning.pptx
PDF
MIND Revenue Release Quarter 2 2025 Press Release
PDF
Blue Purple Modern Animated Computer Science Presentation.pdf.pdf
PDF
Encapsulation theory and applications.pdf
Approach and Philosophy of On baking technology
KodekX | Application Modernization Development
Effective Security Operations Center (SOC) A Modern, Strategic, and Threat-In...
Agricultural_Statistics_at_a_Glance_2022_0.pdf
Per capita expenditure prediction using model stacking based on satellite ima...
Reach Out and Touch Someone: Haptics and Empathic Computing
Electronic commerce courselecture one. Pdf
Spectroscopy.pptx food analysis technology
Diabetes mellitus diagnosis method based random forest with bat algorithm
Mobile App Security Testing_ A Comprehensive Guide.pdf
How UI/UX Design Impacts User Retention in Mobile Apps.pdf
Dropbox Q2 2025 Financial Results & Investor Presentation
MYSQL Presentation for SQL database connectivity
VMware vSphere Foundation How to Sell Presentation-Ver1.4-2-14-2024.pptx
Network Security Unit 5.pdf for BCA BBA.
Architecting across the Boundaries of two Complex Domains - Healthcare & Tech...
20250228 LYD VKU AI Blended-Learning.pptx
MIND Revenue Release Quarter 2 2025 Press Release
Blue Purple Modern Animated Computer Science Presentation.pdf.pdf
Encapsulation theory and applications.pdf

Redbook overview and introduction 8670-61x

  • 1. ibm.com/redbooks Redpaper Front cover IBM Power 720 and 740 Technical Overview and Introduction An Ding Chen James Cruickshank Carlo Costantini Volker Haug Cesar Diniz Maciel John T Schmidt Features the POWER7 processor providing advanced multi-core technology Reducedpowerrequirementswith power-saving functions Describes leading midrange performance
  • 3. International Technical Support Organization IBM Power 720 and 740: Technical Overview and Introduction November 2010 REDP-4637-00
  • 4. © Copyright International Business Machines Corporation 2010. All rights reserved. Note to U.S. Government Users Restricted Rights -- Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. First Edition (November 2010) This edition applies to the IBM Power 720 (8202-E4B) and Power 740 (8205-E6B) Power Systems servers. This document created or updated on December 3, 2012. Note: Before using this information and the product it supports, read the information in “Notices” on page vii.
  • 5. © Copyright IBM Corp. 2010. All rights reserved. iii Contents Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii Trademarks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix The team who wrote this paper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix Now you can become a published author, too! . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xi Comments welcome. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xi Stay connected to IBM Redbooks publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xii Chapter 1. General description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.1 Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1.1.1 The Power 720 server. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1.1.2 The Power 740 server. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1.2 Operating environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.3 Physical package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 1.3.1 Tower model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 1.3.2 Rack-mount model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 1.4 System features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 1.4.1 Power 720 system features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 1.4.2 Power 740 system features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 1.4.3 Minimum features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 1.4.4 Power supply features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 1.4.5 Processor module features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 1.4.6 Memory features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 1.5 Disk and media features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 1.6 I/O drawers for Power 720 and Power 740 servers . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 1.6.1 12X I/O Drawer PCIe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 1.6.2 PCI-X DDR 12X Expansion Drawer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 1.6.3 PCI-X DDR 12X Expansion Drawer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 1.6.4 I/O drawers and usable PCI slot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 1.6.5 EXP 12S SAS Drawer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 1.6.6 EXP 24S SFF Gen2-bay Drawer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 1.7 Comparison between models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 1.8 Build to Order . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 1.9 IBM Editions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 1.9.1 Express editions for IBM i . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 1.9.2 Express editions for Power 720 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 1.10 IBM i Solution Edition for Power 720 and Power 740 . . . . . . . . . . . . . . . . . . . . . . . . . 20 1.11 Model upgrade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 1.11.1 Upgrade considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 1.11.2 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 1.12 Hardware Management Console models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 1.13 System racks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 1.13.1 IBM 7014 Model S25 rack. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 1.13.2 IBM 7014 Model T00 rack. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 1.13.3 IBM 7014 Model T42 rack. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 1.13.4 Feature code 0555 rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 1.13.5 Feature code 0551 rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 1.13.6 Feature code 0553 rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
  • 6. iv IBM Power 720 and 740: Technical Overview and Introduction 1.13.7 The ac power distribution unit and rack content . . . . . . . . . . . . . . . . . . . . . . . . . 27 1.13.8 Rack-mounting rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 1.13.9 Useful rack additions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 1.13.10 OEM rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Chapter 2. Architecture and technical overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 2.1 The IBM POWER7 processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 2.1.1 POWER7 processor overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 2.1.2 POWER7 processor core . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 2.1.3 Simultaneous multithreading. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 2.1.4 Memory access. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 2.1.5 Flexible POWER7 processor packaging and offerings . . . . . . . . . . . . . . . . . . . . . 41 2.1.6 On-chip L3 cache innovation and Intelligent Cache . . . . . . . . . . . . . . . . . . . . . . . 43 2.1.7 POWER7 processor and Intelligent Energy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 2.1.8 Comparison of the POWER7 and POWER6 processors . . . . . . . . . . . . . . . . . . . 44 2.2 POWER7 processor modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 2.2.1 Modules and cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 2.2.2 Power 720 and Power 740 systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 2.3 Memory subsystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 2.3.1 Registered DIMM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 2.3.2 Memory placement rules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 2.3.3 Memory bandwidth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 2.4 Capacity on Demand. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 2.5 Factory deconfiguration of processor cores . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 2.6 Technical comparison of Power 720 and Power 740 . . . . . . . . . . . . . . . . . . . . . . . . . . 51 2.7 System bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 2.8 Internal I/O subsystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 2.8.1 Slot configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 2.8.2 System ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 2.9 Integrated Virtual Ethernet adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 2.9.1 IVE and SEA implementations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 2.9.2 IVE subsystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 2.10 PCI adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 2.10.1 LAN adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 2.10.2 Graphics accelerators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 2.10.3 SCSI and SAS adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 2.10.4 PCIe RAID & SSD SAS Adapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 2.10.5 iSCSI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 2.10.6 Fibre Channel adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 2.10.7 Fibre Channel over Ethernet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 2.10.8 InfiniBand Host Channel adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 2.10.9 Asynchronous adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 2.11 Internal storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 2.11.1 RAID support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 2.11.2 External SAS port and split backplane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 2.11.3 Media bays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 2.12 External I/O subsystems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 2.12.1 PCI-DDR 12X Expansion Drawer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 2.12.2 12X I/O Drawer PCIe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 2.12.3 Dividing SFF drive bays in a 12X I/O drawer PCIe . . . . . . . . . . . . . . . . . . . . . . . 69 2.12.4 12X I/O drawer PCIe and PCI-DDR 12X Expansion Drawer 12X cabling . . . . . 72 2.12.5 12X I/O Drawer PCIe and PCI-DDR 12X Expansion Drawer SPCN cabling . . . 75 2.13 External disk subsystems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
  • 7. Contents v 2.13.1 EXP 12S SAS Expansion Drawer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 2.13.2 EXP 24S SAS Expansion Drawer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 2.13.3 TotalStorage EXP24 disk drawer and tower . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 2.13.4 IBM TotalStorage EXP24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 2.13.5 IBM System Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 2.14 Hardware Management Console . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 2.14.1 HMC functional overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 2.14.2 HMC connectivity to the POWER7 processor based systems . . . . . . . . . . . . . . 84 2.14.3 HMC high availability. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86 2.14.4 HMC code level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 2.15 Integrated Virtualization Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 2.15.1 IBM Systems Director Management Console (SDMC) . . . . . . . . . . . . . . . . . . . . 90 2.16 Operating system support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91 2.16.1 Virtual I/O Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 2.16.2 IBM AIX operating system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 2.16.3 IBM i operating system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 2.16.4 Linux operating system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 2.17 Compiler technology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95 2.18 Energy management. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 2.18.1 IBM EnergyScale technology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 2.18.2 Thermal power management device card. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 Chapter 3. Virtualization. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 3.1 POWER Version 2.2 enhancements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 3.2 POWER Hypervisor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 3.2.1 Virtual SCSI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 3.2.2 Virtual Ethernet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 3.2.3 Virtual Fibre Channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 3.2.4 Virtual (TTY) console . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 3.3 POWER processor modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 3.4 Active Memory Expansion. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107 3.5 PowerVM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 3.5.1 PowerVM editions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 3.5.2 Logical partitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112 3.5.3 Multiple Shared-Processor Pools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 3.5.4 Virtual I/O Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 3.5.5 PowerVM Lx86 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 3.5.6 PowerVM Live Partition Mobility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 3.5.7 Active Memory Sharing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 3.5.8 NPIV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 3.5.9 Operating System support for PowerVM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 3.5.10 POWER7-specific Linux programming support. . . . . . . . . . . . . . . . . . . . . . . . . 127 3.6 System Planning Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128 Chapter 4. Continuous availability and manageability . . . . . . . . . . . . . . . . . . . . . . . . 131 4.1 Reliability. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132 4.1.1 Designed for reliability. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132 4.1.2 Placement of components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 4.1.3 Redundant components and concurrent repair. . . . . . . . . . . . . . . . . . . . . . . . . . 133 4.2 Availability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 4.2.1 Partition availability priority . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 4.2.2 General detection and deallocation of failing components . . . . . . . . . . . . . . . . . 134 4.2.3 Memory protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136
  • 8. vi IBM Power 720 and 740: Technical Overview and Introduction 4.2.4 Cache protection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139 4.2.5 Special Uncorrectable Error handling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140 4.2.6 PCI extended error handling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140 4.3 Serviceability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142 4.3.1 Detecting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143 4.3.2 Diagnosing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147 4.3.3 Reporting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148 4.3.4 Notifying . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150 4.3.5 Locating and servicing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150 4.4 Manageability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154 4.4.1 Service user interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154 4.4.2 IBM Power Systems firmware maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160 4.4.3 Electronic Services and Electronic Service Agent . . . . . . . . . . . . . . . . . . . . . . . 163 4.5 Operating system support for RAS features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164 Related publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167 IBM Redbooks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167 Other publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167 Online resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168 How to get Redbooks publications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169 Help from IBM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169
  • 9. © Copyright IBM Corp. 2010. All rights reserved. vii Notices This information was developed for products and services offered in the U.S.A. IBM may not offer the products, services, or features discussed in this document in other countries. Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead. However, it is the user's responsibility to evaluate and verify the operation of any non-IBM product, program, or service. IBM may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not give you any license to these patents. You can send license inquiries, in writing, to: IBM Director of Licensing, IBM Corporation, North Castle Drive, Armonk, NY 10504-1785 U.S.A. The following paragraph does not apply to the United Kingdom or any other country where such provisions are inconsistent with local law: INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply to you. This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. IBM may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice. Any references in this information to non-IBM websites are provided for convenience only and do not in any manner serve as an endorsement of those websites. The materials at those websites are not part of the materials for this IBM product and use of those websites is at your own risk. IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you. Information concerning non-IBM products was obtained from the suppliers of those products, their published announcements or other publicly available sources. IBM has not tested those products and cannot confirm the accuracy of performance, compatibility or any other claims related to non-IBM products. Questions on the capabilities of non-IBM products should be addressed to the suppliers of those products. This information contains examples of data and reports used in daily business operations. To illustrate them as completely as possible, the examples include the names of individuals, companies, brands, and products. All of these names are fictitious and any similarity to the names and addresses used by an actual business enterprise is entirely coincidental. COPYRIGHT LICENSE: This information contains sample application programs in source language, which illustrate programming techniques on various operating platforms. You may copy, modify, and distribute these sample programs in any form without payment to IBM, for the purposes of developing, using, marketing or distributing application programs conforming to the application programming interface for the operating platform for which the sample programs are written. These examples have not been thoroughly tested under all conditions. IBM, therefore, cannot guarantee or imply reliability, serviceability, or function of these programs.
  • 10. viii IBM Power 720 and 740: Technical Overview and Introduction Trademarks IBM, the IBM logo, and ibm.com are trademarks or registered trademarks of International Business Machines Corporation in the United States, other countries, or both. These and other IBM trademarked terms are marked on their first occurrence in this information with the appropriate symbol (® or ™), indicating US registered or common law trademarks owned by IBM at the time this information was published. Such trademarks may also be registered or common law trademarks in other countries. A current list of IBM trademarks is available on the web at http://www.ibm.com/legal/copytrade.shtml The following terms are trademarks of the International Business Machines Corporation in the United States, other countries, or both: Active Memory™ AIX 5L™ AIX® DS8000® Electronic Service Agent™ EnergyScale™ Focal Point™ IBM Systems Director Active Energy Manager™ IBM® Micro-Partitioning™ Power Architecture® POWER Hypervisor™ Power Systems™ Power Systems Software™ POWER4™ POWER4+™ POWER5™ POWER5+™ POWER6+™ POWER6® POWER7™ PowerHA™ PowerPC® PowerVM™ POWER® pSeries® Rational Team Concert™ Rational® Redbooks® Redpaper™ Redbooks (logo) ® RS/6000® System p5® System p® System Storage® System z® Tivoli® TotalStorage® Workload Partitions Manager™ XIV® The following terms are trademarks of other companies: Microsoft, and the Windows logo are trademarks of Microsoft Corporation in the United States, other countries, or both. Intel, Intel logo, Intel Inside logo, and Intel Centrino logo are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. UNIX is a registered trademark of The Open Group in the United States and other countries. Linux is a trademark of Linus Torvalds in the United States, other countries, or both. Other company, product, or service names may be trademarks or service marks of others.
  • 11. © Copyright IBM Corp. 2010. All rights reserved. ix Preface This IBM® Redpaper™ publication is a comprehensive guide covering the IBM Power 720 and Power 740 servers supporting AIX®, IBM i, and Linux® operating systems. The goal of this paper is to introduce the innovative Power 720 and Power 740 offerings and their major functions, including these: The IBM POWER7™ processor available at frequencies of 3.0 GHz, 3.55 GHz, and 3.7 GHz The specialized POWER7 Level 3 cache that provides greater bandwidth, capacity, and reliability The 1 Gb or 10 Gb Integrated Virtual Ethernet adapter, included with each server configuration, providing native hardware virtualization The latest IBM PowerVM™ virtualization, including PowerVM Live Partition Mobility and PowerVM IBM Active Memory™ Sharing Active Memory Expansion technology that provides more usable memory than is physically installed in the system IBM EnergyScale™ technology that provides features such as power trending, power-saving, capping of power, and thermal measurement Professionals who want to acquire a better understanding of IBM Power Systems™ products can benefit from reading this Redpaper publication. The intended audience includes the following roles: Clients Sales and marketing professionals Technical support professionals IBM Business Partners Independent software vendors This paper complements the available set of IBM Power Systems documentation by providing a desktop reference that offers a detailed technical description of the Power 720 and Power 740 systems. This paper does not replace the latest marketing materials and configuration tools. It is intended as an additional source of information that, together with existing sources, can be used to enhance your knowledge of IBM server solutions. The team who wrote this paper This paper was produced by a team of specialists from around the world working at the International Technical Support Organization, Austin Center, Texas. The project that produced this publication was managed by Scott Vetter. An Ding Chen is a Power systems Product Engineer in Shanghai China, who provides level 3 hardware and firmware support in all Asia Pacific countries and Japan. He has ten years experience on AIX/UNIX®, IBM RS/6000®, IBM pSeries®, and Power Systems products. Starting from his university, he has passed the CATE certification on pSeries systems and IBM AIX 5L™. He joined IBM in 2006.
  • 12. x IBM Power 720 and 740: Technical Overview and Introduction James Cruickshank works on the Power Systems Field Technical Sales Support team for IBM in the UK. He holds an honors degree in Mathematics from the University of Leeds. James has nine years of experience working on RS/6000, IBM System p®, and Power Systems products and is a member of the EMEA Power Champions team. James supports customers in the financial services sector in the UK. Carlo Costantini is a Certified IT Specialist for IBM and has over 32 years of experience with IBM and IBM Business Partners. He currently works in Italy Power Systems Platforms as Presales Field Technical Sales Support for IBM Sales Representatives and IBM Business Partners. Carlo has broad marketing experience and his current major areas of focus are competition, sales, and technical sales support. He is a certified specialist for Power Systems servers. He holds a Masters degree in Electronic Engineering from Rome University. Volker Haug is a certified Consulting IT Specialist within IBM Systems and Technology Group, based in Ehningen, Germany. He holds a Bachelor's degree in Business Management from the university of Applied Studies in Stuttgart. His career has included more than 23 years working in the IBM PLM and Power Systems divisions as a RISC and AIX Systems Engineer. Volker is an expert in Power Systems hardware, AIX, and PowerVM virtualization. He is a member of the EMEA Power Champions team and also a member of the German Technical Expert Council, a affiliate of the IBM Academy of Technology. He has written various books and white papers about AIX, workstations, servers, and PowerVM virtualization. Cesar Diniz Maciel is a Senior Consulting IT Specialist with IBM in the United States. He joined IBM in 1996 as Presales Technical Support for the RS/6000 family of UNIX servers in Brazil, and came to IBM United States in 2005. He is part of the Global Techline team, working on presales consulting for Latin America. He holds a degree in Electrical Engineering from Universidade Federal de Minas Gerais (UFMG) in Brazil. His areas of expertise include Power Systems, AIX, and IBM POWER® Virtualization. He has written extensively on Power Systems and related products. This is his seventh ITSO residency. John T Schmidt is an Accredited IT Specialist for IBM and has ten years experience with IBM and Power Systems. He has a degree in Electrical Engineering from the University of Missouri - Rolla and an MBA from Washington University in St. Louis. In 2010, he completed an assignment with the IBM Corporate Service Corps in Hyderabad, India. He is currently working in the United States as a presales Field Technical Sales Specialist for Power Systems in St. Louis, MO. The project that produced this publication was managed by: Scott Vetter, IBM certified project manager and PMP.
  • 13. Preface xi Thanks to the following people for their contributions to this project: Salim Agha, Ray W. Anderson, Richard W. Bishop, Joe Cahill, Scott A. Carroll, Sertac Cakici, Hsien-I Chang, Binh Chu, Michael Floyd, George Gaylord, John Gressett, Raymond J. Harrington, Daniel Henderson, John Hilburn, Bob Kovacs, Walter M. Lipp, Mary E. Magnuson, Bill McWaters, Duc T. Nguyen, Thoi Nguyen, Guy R. Paradise, David Pirnik, Todd J. Rosedahl, Pat O’Rourke, Amartey S. Pearson, Jeff Scheel, Joseph C. Schiavone, Irene Sideris, Timothy Stack, Guido Somers, Vasu Vallabhaneni, Jesus G. Villarreal IBM U.S.A. Sabine Jordan, Stephen Lutz IBM Germany Tamikia Barrow, Brooke C Gardner International Technical Support Organization, Austin Center Now you can become a published author, too! Here's an opportunity to spotlight your skills, grow your career, and become a published author - all at the same time! Join an ITSO residency project and help write a book in your area of expertise, while honing your experience using leading-edge technologies. Your efforts will help to increase product acceptance and customer satisfaction, as you expand your network of technical contacts and relationships. Residencies run from two to six weeks in length, and you can participate either in person or as a remote resident working from your home base. Find out more about the residency program, browse the residency index, and apply online at: ibm.com/redbooks/residencies.html Comments welcome Your comments are important to us! We want our papers to be as helpful as possible. Send us your comments about this paper or other IBM Redbooks publications in one of the following ways: Use the online Contact us review Redbooks form found at: ibm.com/redbooks Send your comments in an email to: redbooks@us.ibm.com Mail your comments to: IBM Corporation, International Technical Support Organization Dept. HYTD Mail Station P099 2455 South Road Poughkeepsie, NY 12601-5400
  • 14. xii IBM Power 720 and 740: Technical Overview and Introduction Stay connected to IBM Redbooks publications Find us on Facebook: http://www.facebook.com/IBMRedbooks Follow us on twitter: http://twitter.com/ibmredbooks Look for us on LinkedIn: http://www.linkedin.com/groups?home=&gid=2130806 Explore new Redbooks publications, residencies, and workshops with the IBM Redbooks publications weekly newsletter: https://www.redbooks.ibm.com/Redbooks.nsf/subscribe?OpenForm Stay current on recent Redbooks publications with RSS Feeds: http://www.redbooks.ibm.com/rss.html
  • 15. © Copyright IBM Corp. 2010. All rights reserved. 1 Chapter 1. General description The IBM Power 720 (8202-E4B) and IBM Power 740 (8205-E6B) servers utilize the latest POWER7 processor technology designed to deliver unprecedented performance, scalability, reliability, and manageability for demanding commercial workloads. The performance, availability, and flexibility of the Power 720 server can enable companies to spend more time running their business utilizing a proven solution from thousands of ISVs that support the AIX, IBM i, and Linux operating systems. The Power 720 server is a high-performance, energy efficient, reliable, and secure infrastructure and application server in a dense form factor. As a high-performance infrastructure or application server, the Power 720 contains innovative workload-optimizing technologies that maximize performance based on client computing needs and Intelligent Energy features that help maximize performance and optimize energy efficiency, resulting in one of the most cost-efficient solutions for UNIX, IBM i, and Linux deployments. As a distributed application server, the IBM Power 720 is designed with capabilities to deliver leading-edge application availability and enable more work to be processed with less operational disruption for branch office and in-store applications. As a consolidation server, PowerVM Editions provide the flexibility to use leading-edge AIX, IBM i, Linux, and x86 Linux applications and offer comprehensive virtualization technologies designed to aggregate and manage resources while helping to simplify and optimize your IT infrastructure and deliver one of the most cost-efficient solutions for UNIX, IBM i and Linux deployments. The Power 740 offers the performance, capacity, and configuration flexibility to meet the most demanding growth requirements, and combined with industrial-strength PowerVM virtualization for AIX, IBM i, and Linux, can fully utilize the capability of the system. These capabilities are designed to satisfy even the most demanding processing environments and can deliver business advantages and higher client satisfaction. The Power 740 is designed with innovative workload-optimizing and energy management technologies to help clients get the most out of their systems; that is, running applications rapidly and energy efficiently to conserve energy and reduce infrastructure costs. It is fueled by the outstanding performance of the POWER7 processor, making it possible for applications to run faster with fewer processors, resulting in lower per-core software licensing costs. 1
  • 16. 2 IBM Power 720 and 740: Technical Overview and Introduction 1.1 Systems Figure 1-1 shows the Power 720 rack and tower models. Figure 1-1 Power 720 rack and tower models
  • 17. Chapter 1. General description 3 Figure 1-2 shows the Power 740 rack and tower models. Figure 1-2 Power 740 rack and tower models 1.1.1 The Power 720 server The Power 720 offers a choice of a 4-core, 6-core, or 8-core configuration, available in a 4U rack-mount or a tower form factor. The POWER7 processor chips in this server are 64-bit, 4-core, 6-core and 8-core modules with 4 MB of L3 cache per core and 256 KB of L2 cache per core. The Power 720 server supports a maximum of 16 DDR3 DIMM slots, with eight DIMM slots included in the base configuration and eight DIMM slots available with an optional memory riser card. A system with the optional memory riser card installed has a maximum memory of 128 GB. The Power 720 system offers two storage backplanes. The first one supports up to six SFF SAS HDDs/SSDs, an SATA DVD, and a half-high tape drive. The second one is a higher-function backplane that supports up to eight SFF SAS HDDs/SSDs, an SATA DVD, a half-high tape drive, Dual 175 MB Write Cache RAID, and an external SAS port. All HDDs/SSDs are hot-swap and front accessible.
  • 18. 4 IBM Power 720 and 740: Technical Overview and Introduction The Power 720 comes with four PCI Express (PCIe) full height profile slots for installing adapters in the system. Optionally an additional riser card with four PCIe low profile (LP) slots can be installed in a GX++ slot available on the backplane. This extends the number of slots to eight. If additional slots are required, the Power 720 supports external I/O drawers in place of the riser card, allowing for a maximum of two 5802/5877 PCIe drawers or four 5796 PCI-X drawers. Note that only the 6-core and 8-core systems support external I/O slots. In the Power 720 system units there is a choice of quad gigabit or dual 10 Gb Integrated Virtual Ethernet (IVE) adapters. These native ports can be selected at the time of initial order. Virtualization of these integrated Ethernet adapters is supported. 1.1.2 The Power 740 server The IBM Power 740 server is a 4U rack-mount or tower server with two processor sockets offering 4-core 3.3 GHz and 3.7 GHz, 6-core 3.7 GHz, and 8-core 3.55 GHz processor options. The POWER7 processor chips in this server are 64-bit, 4-core, 6-core, and 8-core modules with 4 MB of L3 cache per core and 256 KB of L2 cache per core. The Power 740 server supports a maximum of 32 DDR3 DIMM slots, with eight DIMM slots included in the base configuration and 24 DIMM slots available with three optional memory riser cards. A system with three optional memory riser cards installed has a maximum memory of 256 GB. The Power 740 system offers two storage backplanes. The first supports up to six SFF SAS HDDs/SSDs, an SATA DVD, and a half-high tape drive. The second is a higher-function backplane that supports up to eight SFF SAS HDDs/SSDs, an SATA DVD, a half-high tape drive, Dual 175 MB Write Cache RAID, and an external SAS port. All HDDs/SSDs are hot-swap and front accessible. The Power 740 comes with four PCI Express (PCIe) full height profile slots for installing adapters in the system. Optionally an additional riser card with four PCIe low profile (LP) slots can be installed in a GX++ slot available on the backplane. This extends the number of slots to eight. If additional slots are required, the Power 740 supports external I/O drawers, allowing for a maximum of four 5802/5877 PCIe drawers or four 5796 PCI-X drawers. You also have the choice of quad gigabit or dual 10 Gb Integrated Virtual Ethernet (IVE) adapters for the Power 740 servers. These native ports can be selected at the time of initial order. Virtualization of these integrated Ethernet adapters is supported.
  • 19. Chapter 1. General description 5 1.2 Operating environment The operating environment specifications for the servers can be seen in Table 1-1: Table 1-1 Operating environment for Power 720 and Power 740 Power 720 and Power 740 operating environment Description Operating Non-operating Power 720 Power 740 Power 720 Power 740 Temperature 5 to 35 degrees C (41 to 95 degrees F) Preferable: 18 to 27 degrees C (64 to 80 degrees F) 5 to 45 degrees C (41 to 113 degrees F) Relative humidity 20% to 60% 8% to 80% Maximum dew point 28 degrees C (84 degrees F) 28 degrees C (82 degrees F) Operating voltage 100 to 127 VAC or 200 to 240 VAC 200 to 240 V AC n/a Operating frequency 50 to 60 +/- 3 Hz n/a Power consumption 750 watts maximum 1400 watts maximum n/a Power source loading 0.765 kVA maximum 1.1428 kVA maximum n/a Thermal output 2560 Btu/hour maximum 4778 Btu/hour maximum n/a Maximum altitude 3048 m (10,000 ft) n/a Noise level reference point: Tower system: 5.4 bels (operating/idle) Rack system: 5.4 bels (operating/idle) Tower system: 5.8 bels (operating/idle) Rack system: 5.8 bels (operating/idle) n/a
  • 20. 6 IBM Power 720 and 740: Technical Overview and Introduction 1.3 Physical package The Power 720 and Power 740 are available in both rack-mount and tower form factors. The major physical attributes for each are discussed in the following sections. 1.3.1 Tower model The Power 720 and Power 740 can each be configured as tower models by selecting features shown in Table 1-2. Table 1-2 Features for selecting tower models Table 1-3 shows the physical dimensions of the tower models. Table 1-3 Physical dimensions of the Power 720 and Power 740 tower chassis 1.3.2 Rack-mount model The Power 720 and Power 740 can be configured as 4U (4EIA) rack-mount models by selecting features shown in Table 1-4. Table 1-4 Features for selecting rack-mount models Table 1-5 shows the physical dimensions of the rack-mount models Table 1-5 Physical dimensions of the Power 720 and Power 740 rack-mount chassis Cover Set Power 720 Power 740 IBM Tower Cover Set #7567 #7572 OEM Tower Cover Set #7568 #7573 Dimension Power 720 Power 740 Width without tip plate 183 mm (7.2 in) 183 mm (7.2 in) Width with tip plate 328.5 mm (12.9 in) 328.5 mm (12.9 in) Depth 688 mm (27.1 in) 688 mm (27.1 in) Height 541 mm (21.3 in) 541 mm (21.3 in) Weight without tip plate 53.7 kg (118.1 lb) 53.7 kg (118.1 lb) Weight with tip plate 57.2 kg (125.8 lb) 57.2 kg (125.8 lb) Cover Set Power 720 Power 740 IBM Rack-mount Drawer Bezel and Hardware #7134 #7131 OEM Rack-mount Drawer Bezel and Hardware #7135 #7132 Dimension Power 720 Power 740 Width 440 mm (17.3 in) 440 mm (17.3 in) Depth 610 mm (24.0 in) 610 mm (24.0 in) Height 173 mm (6.81 in) 173 mm (6.81 in) Weight 48.7 kg (107.4 lb) 48.7 kg (107.4 lb)
  • 21. Chapter 1. General description 7 Figure 1-3 shows the rear view of a Power 740 with the optional PCIe expansion. Figure 1-3 Rear view of a rack-mount Power 740 server 1.4 System features The system chassis contains one processor module (Power 720) or up to two processor modules (Power 740). Each POWER7 processor module has either 4-cores, 6-cores, or 8-cores. Each of the POWER7 processor chips in the server has a 64-bit architecture, up to 2 MB of L2 cache (256 KB per core) and up to 32 MB of L3 cache (4 MB per core). 1.4.1 Power 720 system features The following summary describes the standard features: Tower or rack-mount (4U) chassis 4-core, 6-core, or 8-core configuration with one 3.0 GHz processor module Up to 128 GB of 1066 MHz DDR3 ECC memory Choice of two disk/media backplanes: – Six 2.5-inch HDD/SSD/Media backplane with one tape drive bay and one DVD bay – Eight x 2.5-inch HDD/SSD/Media backplane with one tape drive bay, one DVD bay, and one external SAS port External SAS Port Optional 4 x PCIe x8 Slots 4 x PCIe x8 Slots GX++ Slot 1 (shared with PCIe expansion feature) System Ports SPCN Ports Integrated Virtual Ethernet HMC Ports USB Ports GX++ Slot 2
  • 22. 8 IBM Power 720 and 740: Technical Overview and Introduction Choice of three Integrated Virtual Ethernet daughter cards: – Quad-port 1 Gb Copper IVE – Dual-port 10 Gb SFP+ TwinAx Cu IVE – Dual-port 10 Gb SFP+ Fiber IVE A maximum of eight PCIe slots: – Four PCIe x8 full height short card slots – Optional four PCIe x8 low profile short card slots One GX++ slot Integrated: – Service Processor – EnergyScale technology – Hot-swap and redundant cooling – Three USB ports and two system ports – Two HMC ports and two SPCN ports Optional redundant, 1725 Watt ac hot-swap power supplies 1.4.2 Power 740 system features The following summary describes the standard features: Tower or rack-mount (4U) chassis Processors: – 4-core or 8-core configuration with one or two 3.3 GHz or 3.7 GHz 4-core processor modules – 6-core or 12-core configuration with one or two 3.7 GHz 6-core processor modules – 8 or 16-core configuration with two 3.55 GHz 8-core processor modules Up to 256 GB of 1066 MHz DDR3 ECC memory Choice of two disk/media backplanes: – Six x 2.5-inch HDD/SSD/Media backplane with one tape drive bay and one DVD bay – Eight x 2.5-inch HDD/SSD/Media backplane with one tape drive bay, one DVD bay and one external SAS port Choice of three Integrated Virtual Ethernet daughter cards: – Quad-port 1 Gb Copper IVE – Dual-port 10 Gb SFP+ TwinAx Cu IVE – Dual-port 10 Gb SFP+ Fiber IVE A maximum of eight PCIe slots: – Four PCIe x8 full height short card slots – Optional four PCIe x8 low profile short card slots Two GX++ slots Integrated: – Service Processor – EnergyScale technology – Hot-swap and redundant cooling – Three USB ports and two system ports – Two HMC ports and two SPCN ports Redundant, 1725 Watt ac hot-swap power supplies
  • 23. Chapter 1. General description 9 1.4.3 Minimum features Each system has a minimum feature-set in order to be valid. The minimum configuration must include a processor, processor activations, memory, a power supply, a power cord (two power supplies and two power cords for the Power 740), one or two DASD, a DASD/SSD/Media backplane, an Integrated Virtual Ethernet daughter card, a DVD-RAM, an operating system indicator, and a Language Group Specify. If IBM i is the Primary Operating System (#2145), the initial order must also include one additional HDD/SSD, a Mirrored System Disk Level Specify Code, and a System Console on HMC Indicator. A DVD is defaulted on every order but can be de-selected. A DVD-ROM or DVD-RAM must be accessible by the system. 1.4.4 Power supply features One system 1725 watt ac power supply (#5603) is required for the Power 720. A second power supply is optional. Two system 1725 watt ac power supplies (#5603) are required for the Power 740. The second power supply provides redundant power for enhanced system availability. To provide full redundancy, the two power supplies must be connected to separate PDUs. The server will continue to function with one working power supply. A failed power supply can be hot swapped but must remain in the system until the replacement power supply is available for exchange. 1.4.5 Processor module features Each of the processor modules in the system houses a single POWER7 processor chip. The processor has either 4-cores, 6-cores, or 8-cores. The Power 720 supports one processor module. The Power 740 supports a second processor module that must be identical to the first. The amount of processor activation code features must be equal to the amount of installed processor cores. Note: If AIX, IBM i, or Linux is the primary operating system, no internal HDD or SSD is required if feature #0837 (Boot from SAN) is selected. A Fibre Channel or FCoE adapter must be ordered if #0837 is selected.
  • 24. 10 IBM Power 720 and 740: Technical Overview and Introduction Table 1-6 summarizes the processor features available for the Power 720. Table 1-6 Processor features for the Power 720 Table 1-7 summarizes the processor features available for the Power 740. Table 1-7 Processor features for the Power 740 1.4.6 Memory features In POWER7 processor-based systems, DDR3 memory is used throughout. The POWER7 DDR3 memory uses a new memory architecture to provide greater bandwidth and capacity. This enables operating at a higher data rate for larger memory configurations. Memory in the Power 720 and 740 systems installed into memory riser cards. One memory riser card is included in the base system. The base memory riser card does not appear as a feature code in the configurator. Additional memory riser cards, feature #5604, can be installed up to a maximum of two per processor module. Each memory riser card provides eight DDR3 DIMM slots. DIMMs are available in capacities of 4 GB and 8 GB at 1066 MHz. All DIMMs are installed in pairs. Table 1-8 shows memory features available on the systems. Table 1-8 Summary of memory features It is generally best that memory be installed evenly across all memory riser cards in the system. Balancing memory across the installed memory riser cards allows memory access in a consistent manner and typically results in the best possible performance for your configuration. However, balancing memory fairly evenly across multiple memory riser cards, compared to balancing memory exactly evenly typically has a very small performance difference. Feature code Processor module description #8350 4-core 3.0 GHz POWER7 processor module #8351 6-core 3.0 GHz POWER7 processor module #8352 8-core 3.0 GHz POWER7 processor module Feature code Processor module description Min/max modules #8353 4-core 3.3 GHz POWER7 processor module 1/2 #8347 4-core 3.7 GHz POWER7 processor module 1/2 #8354 6-core 3.7 GHz POWER7 processor module 1/2 #8355 8-core 3.55 GHz POWER7 processor module 1/2 Feature code Feature capacity Access rate DIMMs #4526 8 GB 1066 MHz 2 x 4 GB DIMMs #4529a a. A Power 720 system with the 4-core processor module (#8350) does not support the 16 GB memory feature #4529. 16 GB 1066 MHz 2 x 8 GB DIMMs
  • 25. Chapter 1. General description 11 1.5 Disk and media features The Power 720 and 740 systems feature one SAS DASD controller with two storage backplane options: The first (#5618) supports up to six SFF SAS HDDs/SSDs, a SATA DVD, and a half-high tape drive for either a tape drive or USB removable disk. This feature does not provide RAID 5, RAID 6, a write cache, or an external SAS port. Split backplane functionality (3x3) and RAID 10 is supported with the additional feature #5631. The second (#5630) is a higher-function backplane that supports up to eight SFF SAS HDDs/SSDs, a SATA DVD, a half-high tape drive for either a tape drive or USB removable disk, Dual 175 MB Write Cache RAID, and one external SAS port. The #5630 supports RAID 5 and RAID 6 and there is no split backplane available for this feature. All HDDs/SSDs are hot-swap and front accessible. Table 1-9 shows the available disk drive feature codes to be installed in the Power 720 and Power 740. Table 1-9 Disk drive feature code description Notes: No additional PCIe SAS adapter is required for Split Backplane. The feature #5618 is not supported with IBM i. Feature code Description OS support #1775 177 GB SFF-1 SSD w/ eMLC AIX, Linux #1787 177 GB SFF-1 SSD w/ eMLC IBM i #1793 177 GB SFF-2 SSD w/ eMLC AIX, Linux #1794 177 GB SFF-2 SSD w/ eMLC IBM i #1790 600 GB 10K RPM SAS SFF Disk Drive AIX, Linux #1885 300 GB 10K RPM SFF SAS Disk Drive AIX, Linux #1886 146.8 GB 15K RPM SFF SAS Disk Drive AIX, Linux #1888 139.5 GB 15K RPM SFF SAS Disk Drive IBM i #1911 283 GB 10K RPM SFF SAS Disk Drive IBM i #1916 571 GB 10k RPM SAS SFF Disk Drive IBM i #1917 146 GB 15k RPM SAS SFF-2 Disk Drive AIX, Linux #1925 300 GB 10k RPM SAS SFF-2 Disk Drive AIX, Linux #1947 139 GB 15k RPM SAS SFF-2 Disk Drive IBM i #1956 283 GB 10k RPM SAS SFF-2 Disk Drive IBM i #1962 571 GB 10k RPM SAS SFF-2 Disk Drive IBM i #1964 600 GB 10k RPM SAS SFF-2 Disk Drive AIX, Linux #1995 177 GB 1.8” SATA Solid State Drive AIX, Linux #1996 177 GB 1.8” SATA Solid State Drive IBM i
  • 26. 12 IBM Power 720 and 740: Technical Overview and Introduction #1817 Quantity 150 of #1962 #1818 Quantity 150 of #1964 #1844 Quantity 150 of #1956 #1866 Quantity 150 of #1917 #1868 Quantity 150 of #1947 #1869 Quantity 150 of #1925 #1887 Quantity 150 of #1793 #1958 Quantity 150 of #1794 Feature code Description OS support
  • 27. Chapter 1. General description 13 Note: Be aware of the following considerations for disks: No internal HDD/SSD is required if #0837 is selected. This will indicate a boot from SAN. In this case, a Fibre Channel or Fibre Channel over Ethernet adapter must also be ordered. SSDs are not supported by #5278 or #5901, and #5912 SAS adapters. SAS-bay-based SSD options are enhanced with a 177 GB SSD, with eMLC (#1775, #1787) which provides 2.5 times more capacity per drive than the current 69 GB SSD (#1890 and #1909. The 177 GB drive provides a much improved cost per gigabyte and requires a smaller number of SAS bays for the same number of gigabytes. A few SSDs may reduce the need for many HDDs, saving rack space, I/O drawers, maintenance, and energy. SSDs can often do so while improving system performance and batch windows at the same time. Four feature codes are used for this drive to indicate if it is used for AIX/Linux or IBM i and to indicate what type of SFF SAS bay in which it is placed .Two features (#1793, and #1794) are Gen2 carrier for use on the EXP 24S SFF Gen2-bay Drawer (#5887) The SSDs #1775, #1787, #1793 and #1794 can be controlled by: – The imbedded SAS controllers in the previously listed POWER7 system units (Power 710 and Power 740). – The PCIe 380 MB Cache SAS RAID Adapter (#5805) – The PCI-X 1.5 GB Cache SAS RAID Adapter (#5908) The maximum number of SSD drive features per controller depends upon the enclosure in which the SSD are placed and the SAS controller, which is running the SSD. – Imbedded SAS controllers can attach up to the maximum number of bays in the system unit, an attachment maximum of six or eight. – The PCIe 380 MB Cache SAS RAID Adapter (#5805) can attach up to a total of nine SSD per pair of adapters. – The PCI-X 1.5 GB Cache SAS RAID Adapter (#5908) can attach up to a total of eight SSD. SSDs and HDDs are not allowed to mirror each other. SSF-2 disk drives require a Gen2 SFF carrier/tray for use in an EXP 24S I/O drawer(#5887). The 177 GB SAS SSD (#1995 and #1996) requires to be installed into one of the PCIe RAID & SSD SAS adapters (#2053, #2054, or #2055). For more detailed information about this option, see 2.10.4, “PCIe RAID & SSD SAS Adapter” on page 58. In a Power 720 and Power 740 with a split backplane, SSDs and HDDs may be placed in either "split" but no mixing of SSDs and HDDs within a split is allowed. IBM i does not support split backplane. In a Power 720 and Power 740 without a split backplane, SSDs and HDDs may be mixed in any combination. However, they cannot be in the same RAID array. If IBM i is the primary operating system (#2145), a minimum of two HDDs/SSDs are required.
  • 28. 14 IBM Power 720 and 740: Technical Overview and Introduction If you need more disks than available with the internal disk bays, you can attach additional external disk subsystems. SCSI disks are not supported in the Power 720 and 740 disk bays. However, if you want to use SCSI disks, you can attach existing SCSI disk subsystems. For more detailed information about the available external disk subsystems, see 2.13, “External disk subsystems” on page 75. The Power 720 and 740 have a slim media bay that can contain an optional DVD-RAM (#5762) and a half-high bay that can contain a tape drive or removable disk drive. Table 1-10 shows the available media device feature codes for Power 720 and 740. Table 1-10 Media device feature code description for Power 720 and 740 1.6 I/O drawers for Power 720 and Power 740 servers The Power 720 and the Power 740 servers supports the following 12X attached I/O drawers, providing extensive capability to expand the overall server expandability and connectivity. Feature #5802 provides PCIe slots and SFF SAS disk slots Feature #5877 provides PCIe slots Feature #5796 provides PCI-X slots The 7314-G30 drawer provides PCI-X slots (because the 7314-G30 has been withdrawn from marketing it is supported, but no longer orderable) Three disk-only I/O drawers are also supported, providing large storage capacity and multiple partition support: Feature #5886 EXP 12S holds a 3.5-inch SAS disk or SSD Feature #5887 EXP 24S SFF Gen2-bay Drawer for high-density storage holds SAS Hard Disk drives. Feature code Description #5762 SATA Slimline DVD-RAM Drive #5619 80/160 GB DAT160 Tape-SAS #5638 1.5 TB/3.0 TB LTO-5 Tape-SAS #5746 800 GB/1.6 TB LTO4 Tape-SAS #1103 USB Internal Docking Station for Removable Disk Drive #1104 USB External Docking Station for Removable Disk Drive Note: Take notice of the following considerations for tape drives and USB disk drives: If tape device feature #5619, #5638, or #5746 is installed in the half-high media bay, feature #3656 must be also selected. A half-high tape feature and a feature #1103 Removable USB Disk Drive Docking Station are mutually exclusive. One or the other can be in the half-high bay in the system but not both. As for the tape drive, the #3656 is not required with #1103.
  • 29. Chapter 1. General description 15 Feature #5786 and #5787 EXP24 holds a 3.5-inch SCSI disk (used for migrating existing SCSI drives). The 7031-D24 holds a 3.5-inch SCSI disk (supported but not orderable). The Power 720 provides one GX++ slot, offering one loop. The Power 740 has one GX++ slot, if one processor module is installed, and two GX++ slots, when two processor modules are installed. Thus, the Power 740 provides one or two loops. 1.6.1 12X I/O Drawer PCIe The #5802 and #5877 expansion units are 19-inch, rack-mountable, I/O expansion drawers that are designed to be attached to the system using 12x double date rate (DDR) cables. The expansion units can accommodate ten generation 3 blind-swap cassettes. These cassettes can be installed and removed without removing the drawer from the rack. A maximum of two #5802 drawers can be placed on the same 12X loop. The #5877 drawer is the same as #5802 except it does not support any disk bays. The #5877 I/O drawer can be on the same loop as the #5802 I/O drawer. Note that #5877 cannot be upgraded to #5802. The I/O drawer has the following attributes: Eighteen SAS hot-swap SFF disk bays (only #5802) Ten PCI-e based I/O adapter slots. Blind-swap Redundant hot-swappable power and cooling units 1.6.2 PCI-X DDR 12X Expansion Drawer The PCI-X DDR 12X Expansion Drawer (#5796) is a 4 EIA unit tall drawer and mounts in a 19-inch rack. Feature 5796 takes up half the width of the 4 EIA rack space and requires the use of a #7314 drawer mounting enclosure. The 4 EIA tall enclosure can hold up to two #5796 drawers mounted side by side in the enclosure. A maximum of four #5796 drawers can be placed on the same 12X loop. The I/O drawer has the following attributes: 4 EIA unit rack-mount enclosure (#7314) holding one or two #5796 drawers. Six PCI-X DDR slots: 64-bit, 3.3V, 266 MHz. Blind-swap. Redundant hot-swappable power and cooling units. Note: The 4-core Power 720 does not support the attachment of 12X I/O drawers or the attachment of disk drawers such as the #5886 EXP12S drawer, #5786 EXP24 drawer, and #5787 EXP24 tower. Note: Mixing #5802/5877 and #5796 on the same loop is not supported. Mixing #5802 and #5877 on the same loop is supported with a maximum of two drawers total per loop. Note: Mixing #5802/5877 and #5796 on the same loop is not supported. Mixing #5796 and the 7314-G30 on the same loop is supported with a maximum of four drawers total per loop.
  • 30. 16 IBM Power 720 and 740: Technical Overview and Introduction 1.6.3 PCI-X DDR 12X Expansion Drawer The 7314-G30 is equivalent to the #5796 I/O drawer described before. It provides the same six PCI-X DDR slots per unit and has the same configuration rules/considerations as #5796. 1.6.4 I/O drawers and usable PCI slot The various I/O drawer model types can be intermixed on a single server within the appropriate I/O loop. Depending on the system configuration, the maximum number of I/O drawers supported can vary. Table 1-11 summarizes the maximum number of I/O drawers supported and the total number of PCI slots available when expansion consists of a single drawer type. Table 1-11 Maximum number of I/O drawers supported and total number of PCI slots Table 1-12 summarizes the maximum number of disk only I/O drawers supported . Table 1-12 Maximum number of disk only I/O drawers supported 1.6.5 EXP 12S SAS Drawer The EXP 12S SAS drawer (#5886) is a 2 EIA drawer and mounts in a 19-inch rack. The drawer can hold either SAS disk drives or SSD. The EXP 12S SAS drawer has twelve 3.5-inch SAS disk bays with redundant data paths to each bay. The SAS disk drives or SSDs contained in the EXP12S are controlled by one or two PCIe or PCI-X SAS adapters connected to the EXP12S via SAS cables. Note: IBM i does not support the 7314-G30 I/O drawer. Server Processor cards Max #5796 drawers Max #5802 and #5877 drawersa Total number of slots #5796 #5802 and #5877 PCI-X PCIe PCI-X PCIe Power 720 one 4 2 24 8a a. Four additional slots are low profile PCIe slots only. 0 28a Power 740 one 4 2 24 8a 0 28a Power 740 two 8 4 48 8a 0 48a Server Processor cards Max #5886 drawers Max #5887 drawers Max #7314-G30 drawers Power 720 one 28 14 4 Power 740 one 28 14 4 Power 740 two 28 14 8 Note: The Power 720 4-core model does not support the 12X I/O drawer.
  • 31. Chapter 1. General description 17 The feature 5886 can also be directly attached to the SAS port on the rear of the Power 720, providing a very low cost disk storage solution. When used this way, the imbedded SAS controllers in the system unit drive the disk drives in EXP12S. A second unit cannot be cascaded to a feature 5886 attached in this way. 1.6.6 EXP 24S SFF Gen2-bay Drawer The EXP24S SFF Gen2-bay Drawer is an expansion drawer with twenty-four 2.5- inch form factor (SFF) SAS bays. It supports up to 24 hot-swap SFF SAS HDDs on POWER6 or POWER7 servers in 2U of 19-inch rack space. The EXP24S bays are controlled by SAS adapters/controllers attached to the I/O drawer by SAS X or Y cables. The SFF bays of the EXP24S are different from the SFF bays of the POWER7 system units or 12X PCIe I/O Drawers (#5802, #5803). The EXP24S uses Gen-2 or SFF-2 SAS drives that physically do not fit in the Gen-1 or SFF-1 bays of the POWER7 system unit or 12X PCIe I/O Drawers or vice versa 1.7 Comparison between models The Power 720 and Power 740 offers a variety of configuration options where the POWER7 processor has 4-cores at 3.0, 3.3, or 3.7 GHz, 6-cores at 3.0 or 3.7 GHz, or 8-cores at 3.0 or 3.55 GHz. The POWER7 processor has 4 MB of on-chip L3 cache per core. For the 4-core version there is 16 MB, for the 6-core version there is 24 MB of L3 cache available, whereas for the 8-core version there is 32 MB of L3 cache available. Table 1-13 summarizes the various processor core options and frequencies and matches them to the L3 cache sizes. Table 1-13 Summary of processor core counts, core frequencies, and L3 cache sizes 1.8 Build to Order You can perform a Build to Order or a la carte configuration using the IBM Configurator for e-business (e-config) where you specify each configuration feature that you want on the system. You build on top of the base required features, such as the embedded Integrated Virtual Ethernet adapter. System Cores per POWER7 chip Frequency (GHz) L3 Cache per POWER7 chip Min/Max cores per system Power 720 4 3.0 16 MB 4 Power 720 6 3.0 24 MB 6 Power 720 8 3.0 32 MB 8 Power 740 4 3.3 16 MB 4-8 Power 740 4 3.7 16 MB 4-8 Power 740 6 3.7 24 MB 6-12 Power 740 8 3.55 32 MB 16
  • 32. 18 IBM Power 720 and 740: Technical Overview and Introduction Preferably, begin with one of the available starting configurations, such as the IBM Editions. These solutions are available at initial system order time with a starting configuration that is ready to run as is. 1.9 IBM Editions IBM Editions are available only as initial order. If you order a server IBM Edition as defined next, you can qualify for half the initial configuration's processor core activations at no additional charge. The total memory (based on the number of cores) and the quantity/size of disk, SSD, Fibre Channel adapters, or Fibre Channel over Ethernet (FCoE) adapters shipped with the server are the only features that determine if a customer is entitled to a processor activation at no additional charge. When you purchase an IBM Edition, you can purchase an AIX, IBM i, or Linux operating system license, or you can choose to purchase the system with no operating system. The AIX, IBM i, or Linux operating system is processed by means of a feature code on AIX 5.3 or 6.1, or 7.1; IBM i 6.1.1 or IBM i 7.1; and SUSE Linux Enterprise Server or Red Hat Enterprise Linux. If you choose AIX 5.3, 6.1, or 7.1 for your primary operating system, you can also order IBM i 6.1.1 or IBM i 7.1 and SUSE Linux Enterprise Server or Red Hat Enterprise Linux. The converse is true if you choose an IBM i or Linux subscription as your primary operating system. These sample configurations can be changed as needed and still qualify for processor entitlements at no additional charge. However, selection of total memory or HDD or SSD/Fibre Channel/FCoE adapter quantities smaller than the totals defined as the minimums disqualifies the order as an IBM Edition, and the no-charge processor activations are then removed. Consider the following minimum definitions for IBM Editions: For Power 720, a minimum of 2 GB memory per core is needed to qualify for the IBM Edition, except on the 6-core IBM Edition, where effectively there is a 16 GB minimum memory requirement. For example, a 2-core minimum is 8 GB, a 6-core minimum is 16 GB, and an 8-core minimum is 16 GB. There can be other valid memory configurations that meet the minimum requirement. However, the 1 x 16 GB feature (#4529) is not supported. This feature must always be ordered in pairs. For the Power 740, a minimum of 4 GB memory per core is needed to qualify for the IBM Edition, except on the 6-core IBM Edition where there is effectively a 32 GB minimum memory requirement. For example, a 4-core minimum is 16 GB, a 6-core minimum is 32 GB, an 8-core minimum is 32 GB, and a 16-core is 64 GB. There can be other valid memory configurations that meet the minimum requirement. However, 1 x 16 GB feature (#4529) is not supported. This feature must always be ordered in pairs. Also, a minimum of two HDD, or two SSD, or two Fibre Channel adapters, or two FCoE adapters are required. You only need to meet one of these disk/SSD/FC/FCoE criteria. Partial criteria cannot be combined. 1.9.1 Express editions for IBM i Express editions for IBM i enable initial ease of ordering and feature a lower price than if you ordered them a la carte or build-to-order. Taking advantage of the edition is the only way you
  • 33. Chapter 1. General description 19 can use no-charge features for processor activations and IBM i user license entitlements. The Express editions are available only during the initial system order and cannot be ordered after your system is shipped. The IBM configurator offers these easy-to-order Express editions that include no-charge activations or no-charge IBM i user entitlements. You can modify the Express Edition configurations to match your exact requirements for your initial shipment by increasing or decreasing the configuration. If you create a configuration that falls below any of the defined minimums, the IBM configurator replaces the no-charge features with equivalent function regular charge features. 1.9.2 Express editions for Power 720 In order to configure a Power 720 4-core Express Edition for IBM i (#0774) and use the no-charge features on your initial order, you must order the following components: 3.0 GHz 4-core processor module (#8350) IBM i Primary Operating System Indicator (#2145) 8 GB minimum memory - 1 x 8 GB (2 x 4 GB DIMMs) (#4526) A minimum of two HDDs, or two SSDs, or two Fibre Channel adapters, or two FCoE adapters. You only need to meet one of these disk/SSD/FC/FCoE criteria. Partial criteria cannot be combined. If the foregoing requirements are met, the following features are included: Two no-charge activations (2 x #8363) IBM i 5 user entitlements (no-charge) One IBM i Access Family license with unlimited users (57xx-XW1) Reduced price on 57xx-WDS and 5733-SOA For a Power 720 6-, 8-core Express Edition for IBM i (#0778) configuration in combination with the no-charge features on your initial order, you must order: 3.0 GHz 6-core processor module (#8351) or 3.0 GHz 8-core processor module (#8352) IBM i Primary Operating System Indicator (#2145) 16 GB minimum memory - 2 x 8 GB (2 x 4 GB DIMMs) (#4526) or 2 x 16 GB (2 x 8 GB DIMMs) (#4529) A minimum of two HDDs, or two SSDs, or two Fibre Channel adapters, or two FCoE adapters. You only need to meet one of these disk/SSD/FC/FCoE criteria. Partial criteria cannot be combined. If the foregoing requirements are met, the following features are included: Three no-charge activations (3 x #8364) with #8351 or four no-charge activations (4 x #8365) with #8352 Six activations, 3 x #8361 (chargeable) and 3 x #8364 (no-charge), with 6-core #8351 IBM i 30 user entitlements (charged) One IBM i Acces?s Family license with unlimited users (57xx-XW1) Reduced price on 57xx-WDS and 5733-SOA Note: Memory feature #4529 is not supported with the 4-core processor module.
  • 34. 20 IBM Power 720 and 740: Technical Overview and Introduction 1.10 IBM i Solution Edition for Power 720 and Power 740 The IBM i Solution Editions for Power 720 and Power 740 are designed to help you take advantage of the combined experience and expertise of IBM and independent software vendors (ISVs) in building business value with your IT investments. A qualifying purchase of software, maintenance, services or training for a participating ISV solution is required when purchasing an IBM i Solution Edition. The Power 720 Solution edition (#4971) supports both 6-core and 8-core configurations. For a list of participating ISVs, registration form and additional details, visit the Solution Edition website: http://www-03.ibm.com/systems/power/hardware/editions/solutions.html The Power 720 Solution Edition includes no-charge features resulting in a lower initial list price for qualifying clients. Also included is an IBM Service voucher to help speed implementation of the ISV solution. The Power 740 Solution edition supports all processor configurations. For a list of participating ISVs, registration form and additional details, visit the Solution Edition website: http://www-03.ibm.com/systems/power/hardware/editions/solutions.html The Power 740 Solution Edition includes no-charge features resulting in a lower initial list price for qualifying clients. Also included is an IBM Service voucher to help speed implementation of the ISV solution. The requirements to be eligible to purchase a Solution Edition order are as follows: The offering must include new and/or upgrade software licenses and/or software maintenance from the ISV for the qualifying IBM server. Services and/or training for the qualifying server can also be provided. Proof of purchase of the solution with a participating ISV must be provided to IBM on request. The proof must be dated within 90 days before or after the date of order of the qualifying server. Note: The Power 740 does not have an Express Edition for the IBM i feature code available.
  • 35. Chapter 1. General description 21 1.11 Model upgrade Clients can upgrade from a Power 520 to the Power 720, preserving the existing serial number. You can upgrade the Power 520 server (8203-E4A) into the Power 720 (8202-E4B). The 9408-M25 needs first to be converted to a Power 520 (8203-E4A) and then upgraded to Power 720. The upgrade will not produce a lower-priced hardware configuration compared to a new server with a new serial number. However, the upgrade will keep the same licensing in place for AIX and IBM i. Retaining the IBM i licensing can be a very significant advantage. Feature conversions are used to help identify the components that are returned to IBM with the upgrade. 1.11.1 Upgrade considerations Feature conversions have been set up for the following processors: IBM POWER6® and IBM POWER6+™ processors to POWER7 processors Table 1-14 shows conversions for the processors. Table 1-14 Processor conversions 1.11.2 Features The following features present on the current system can be moved to the new system: PCIe adapters with cables Line cords, keyboards, and displays PowerVM (#5525, #5227, #5228) I/O drawers (#5786, #5796, #5802, #5877, and #5886) Racks (#0551, #0553, and #0555) Rack doors (#6068, #6069, #6248, and #6249) Power 520 Power 720 #5634 2-core 4.2 GHz Processor Card #8351 6-core 3.0 GHz POWER7 Processor Module #5577 2-core 4.7 GHz Processor Card #8351 6-core 3.0 GHz POWER7 Processor Module #5578 One Processor Activation for Processor Feature #5577 #8351 6-core 3.0 GHz POWER7 Processor Module #5634 2-core 4.2 GHz Processor Card #8352 8-core 3.0 GHz POWER7 Processor Module #5577 2-core 4.7 GHz Processor Card #8352 8-core 3.0 GHz POWER7 Processor Module #5578 One Processor Activation for Processor Feature #5577 #8352 8-core 3.0 GHz POWER7 Processor Module Notes: The POWER6 processor module feature has two or four cores and a POWER7 processor has six or eight cores. The conversion pricing takes this core difference into consideration. Also note that all processor activation features will have to be added. Priced (#8361 and #8362) and zero-priced (#8364 and #8365) processor activations will be applied according to the IBM Edition qualification rules.
  • 36. 22 IBM Power 720 and 740: Technical Overview and Introduction Rack trim kits (#6246 and 6247) SATA DVD-ROM (#5743) SATA DVD-RAM (#5762) The Power 720 can support the following 12X drawers and disk-only drawers: #5802 and #5877 PCIe 12X I/O drawers #5796 and 7413-G30 PCI-X (12X) I/O Drawer #5786 and 7031-D24 IBM TotalStorage® EXP24 SCSI Disk Drawer #5886 EXP12S SAS Disk Drawer #5887 EXP 24S SFF Gen2-bay Drawer It is important to summarize other key points beyond I/O drawers: 15k rpm SCSI drives that are 69 GB, or higher, are supported (10k rpm SCSI or 15k rpm SCSI drives of less than 69 GB are not supported). All SAS disk drives supported on the POWER6 rack/tower servers are supported. Quarter Inch Cartridge (QIC) tape drives are not supported. Many newer, faster, larger-capacity replacement options are available. IBM i IOPs are not supported, which impacts any older PCI adapters that require an IOP. This can impact older I/O devices such as tape libraries or optical drive libraries or any HVD SCSI device. It means twinax displays/printers cannot be attached except by an OEM protocol converter. It means SDLC-attached devices using a LAN/WAN adapter are not supported. SNA applications still can run when encapsulated inside TCP/IP, but the physical device attachment cannot be SNA. It means that the earlier Fibre Channel and SCSI controllers that depended upon an IOP being present are not supported. 1.12 Hardware Management Console models If you want to implement partitions, a Hardware Management Console (HMC) or the Integrated Virtualization Manager (IVM) or the new released IBM Systems Director Management Console (SDMC) is required to manage the Power 720 and Power 740 servers. Multiple POWER6 and POWER7 processor-based servers can be supported by a single HMC or SDMC. If an HMC is used to manage any POWER7 processor-based server, the HMC must be a rack-mount model CR3, or later, or tower model C05, or later. The HMC provides a set of functions that are necessary to manage the system, for example: Creating and maintaining a multiple partition environment Displaying a virtual operating system session terminal for each partition Displaying a virtual operator panel for each partition Detecting, reporting, and storing changes in hardware conditions Powering managed systems on and off Note: In the Power 720 system unit SAS bays, only the SAS SFF hard disks or SFF solid-state drives are supported internally. The 3.5-inch HDD or SSD can be attached to the Power 720 but must be located in a EXP 12S drawer (#5886). Note: If you do not use an HMC or IVM or SDMC, the Power 720 and Power 740 runs in full system partition mode, meaning that a single partition owns all the server resources and only one operating system can be installed.
  • 37. Chapter 1. General description 23 Acting as a service focal point for service representatives to determine an appropriate service strategy Several HMC models are supported to manage POWER7 based systems. At the time of writing, four models (7042-C07, 7042-C08, 7042-CR5, and 7042-CR6) are available for ordering, but you can also use the withdrawn models listed in Table 1-15. Table 1-15 HMC models supporting POWER7 processor technology based servers For the IBM Power 720 and IBM Power 740 the Licensed Machine Code Version 7 Revision 720 is required. Existing HMC models 7310 can be upgraded to Licensed Machine Code Version 7 to support environments that can include IBM POWER5™, IBM POWER5+™, POWER6, and POWER7 processor-based servers. Licensed Machine Code Version 6 (#0961) is not available for 7042 HMCs. When IBM Systems Director is used to manage an HMC, or if the HMC manages more than 254 partitions, the HMC must have 3 GB of RAM minimum and be a rack-mount CR3, or later, or deskside C06, or later, deskside. IBM SDMC The SDMC is intended to be used in the same manner as the HMC. It provides the same functionality, including hardware, service, and virtualization management, for your Power Systems server and Power Systems blades. Because SDMC uses IBM Systems Director Express® Edition, it also provides all Systems Director Express capabilities, such as monitoring of operating systems and creating event action plans. Much of the SDMC function is equivalent to the HMC. This includes: Server (host) management Virtualization management Transition of configuration data: no configuration changes are required when a client moves from HMC management to SDMC management. Type-model Availability Description 7310-C05 Withdrawn IBM 7310 Model C05 Desktop Hardware Management Console 7310-C06 Withdrawn IBM 7310 Model C06 Deskside Hardware Management Console 7042-C06 Withdrawn IBM 7042 Model C06 Deskside Hardware Management Console 7042-C07 Available IBM 7042 Model C07 Deskside Hardware Management Console 7042-C08 Available IBM 7042 Model C08 Deskside Hardware Management Console 7310-CR3 Withdrawn IBM 7310 Model CR3 Rack-mounted Hardware Management Console 7042-CR4 Withdrawn IBM 7042 Model CR4 Rack-mounted Hardware Management Console 7042-CR5 Available IBM 7042 Model CR5 Rack-mounted Hardware Management Console 7042-CR6 Available IBM 7042 Model CR6 Rack-mounted Hardware Management Console Note: You can download or order the latest HMC code from the Fix Central website: http://www.ibm.com/support/fixcentral
  • 38. 24 IBM Power 720 and 740: Technical Overview and Introduction Redundancy and high availability: The SDMC offers console redundancy similar to the HMC In most cases, the scalability and performance of SDMC matches that of a current HMC. This includes both the number of systems (hosts) and the number of partitions (virtual servers) that can be managed. Currently, 48 small-tier entry servers or 32 large-tier servers can be managed by the SDMC with up to 1,024 partitions (virtual servers) configured across those managed systems (hosts). The SDMC can be obtained as a hardware appliance-in the same manner as an HMC. Hardware appliances support managing all Power Systems servers. The SDMC can optionally be obtained in a virtual appliance format, capable of running on VMware (ESX/i 4, or later), and KVM (Red Hat Enterprise Linux® (RHEL) 5.5). The virtual appliance is only supported or managing small-tier Power® servers and Power Systems blades. Table 1-16 and Table 1-17 detail whether the SDMC software appliance, hardware appliance, or both are supported for each model. Table 1-16 Type of SDMC appliance support for POWER7 based server Table 1-17 Type of SDMC appliance support for POWER6 based server POWER7 models Type of SDMC appliance supported 7891-73X, 7891-74X PS703, PS704 Hardware or software appliance 8202-E4B (IBM Power 720 Express®) Hardware or software appliance 8205-E6B (IBM Power 740 Express) Hardware or software appliance 8406-70Y PS700 Hardware or software appliance 8406-71Y PS701,702 Hardware or software appliance 8231-E2B (IBM Power 710 and IBM Power 730 Express) Hardware or software appliance 8233-E8B (IBM Power 750 Express) Hardware or software appliance 8236-E8C (IBM Power 755) Hardware or software appliance 9117-MMB (IBM Power 770) Hardware appliance only 9119-FHB (IBM Power 795) Hardware appliance only 9179-MHB (IBM Power 780) Hardware appliance only POWER6 models Type of SDMC appliance supported 7778-23x JS23 Hardware or software appliance 7998-60X JS12 Hardware or software appliance 7998-61X JS22 Hardware or software appliance 8203-E4A (Power 520 Express) Hardware or software appliance 8204-E8A (Power 550 Express) Hardware or software appliance 8234-EMA (Power 560 Express) Hardware appliance only 8261-E4S (IBM Smart Cubes) Hardware or software appliance 9406-MMA (Power 570) Hardware appliance only 9407-M15 (Power 520 Express) Hardware or software appliance
  • 39. Chapter 1. General description 25 The IBM SDMC Hardware Appliance requires: An IBM 7042 Rack-mounted Hardware Management Console and IBM SDMC indicator (#0963). The IBM SDMC Virtual Appliance requires: IBM Systems Director Management Console V6.7.3 (5765-MCV) SDMC on Power Systems POWER6 processor-based servers and blades requires eFirmware level 3.5.7. SDMC on Power Systems POWER7 processor-based servers and blades requires eFirmware level 7.3.0. 1.13 System racks •The Power 720 and Power 740 and its I/O drawers are designed to mount in the 25U 7014-S25 (#0555), 36U 7014-T00 (#0551), or the 42U 7014-T42 (#0553) rack. These racks are built to the 19-inch EIA standard.? 9408-M25 (Power 520 Express) Hardware or software appliance 9409-M50 (Power 550 Express) Hardware or software appliance 9117-MMA (Power 570) Hardware appliance only 9119-FHA (Power 595) Hardware appliance only 9125-F2A (Power 575) Hardware appliance only Note: When ordering #0963, you must also order features #0031(No Modem) , #1946 (additional 4GB (2X2GB), 1.333GHz DDR3) and #1998 (additional 500GB SATA HDD). Feature # 0963 replaces the HMC software with IBM Systems Director Management Console Hardware Appliance V6.7.3 (5765-MCH). Neither an external modem (#0032) nor an internal modem (#0033) may be selected with IBM SDMC (#0963). To run HMC LMC (#0962), you cannot order the additional storage (#1998); however, you can order the additional memory (#1946) if wanted. Note: For the software appliance, customer is responsible for providing the hardware and and virtualization environment. At a minimum, the following resources should be available to the virtual machine: 2.53 GHz Intel Xeon E5630, Quad Core processor 500 MB storage 6 GB memory The hypervisors supported are: VMware (ESX/i 4.0, or later) KVM (RHEL 5.5) POWER6 models Type of SDMC appliance supported
  • 40. 26 IBM Power 720 and 740: Technical Overview and Introduction If a system is to be installed in a non-IBM rack or cabinet, ensure that the rack meets the requirements that are described in 1.13.10, “OEM rack” on page 32. 1.13.1 IBM 7014 Model S25 rack The 1.3 Meter (49-inch) Model S25 rack has the following features: 25 EIA units Weights: – Base empty rack: 100.2 kg (221 lb.) – Maximum load limit: 567.5 kg (1250 lb.) The S25 racks do not have vertical mounting space that will accommodate #7188 PDUs. All PDUs required for application in these racks must be installed horizontally in the rear of the rack. Each horizontally mounted PDU occupies 1U of space in the rack, and therefore reduces the space available for mounting servers and other components. 1.13.2 IBM 7014 Model T00 rack The 1.8 Meter (71-in.) Model T00 is compatible with past and present IBM Power systems. The T00 rack has the following features: It has 36 EIA units (36 U) of usable space. The following optional features are available: – Optional removable side panels. – Optional highly perforated front door. – Optional side-to-side mounting hardware for joining multiple racks. You have a choice of standard business black or optional white color in OEM format. Increased power distribution and weight capacity is provided. Support for both ac and dc configurations is included. The rack height is increased to 1926 mm (75.8 in.) if a power distribution panel is fixed to the top of the rack. Up to four power distribution units (PDUs) can be mounted in the PDU bays (Figure 1-4 on page 28), but others can fit inside the rack. See 1.13.7, “The ac power distribution unit and rack content” on page 27. Weights are as follows: – T00 base empty rack: 244 kg (535 lb.) – T00 full rack: 816 kg (1795 lb.) Note: A new Power 720 or Power 740 server is ordered with the appropriate 7014 rack model. The racks are available as features of the Power 720 and Power 740 only when an additional I/O drawer for an existing system (MES order) is ordered. The rack feature number must be used if IBM manufacturing has to integrate the newly ordered I/O drawer in a 19-inch rack before shipping the MES order. Note: It is the client’s responsibility to ensure that the installation of the drawer in the preferred rack or cabinet results in a configuration that is stable, serviceable, safe, and compatible with the drawer requirements for power, cooling, cable management, weight, and rail security.
  • 41. Chapter 1. General description 27 1.13.3 IBM 7014 Model T42 rack The 2.0 meter (79.3-inch) Model T42 addresses the client requirement for a tall enclosure to house the maximum amount of equipment in the smallest possible floor space. The following features differ in the Model T42 rack from the Model T00: There are 42 EIA units (42 U) of usable space (6 U of additional space). The Model T42 supports ac only. Rack weights are as follows: – T42 base empty rack: 261 kg (575 lb.) – T42 full rack: 930 kg (2045 lb.) 1.13.4 Feature code 0555 rack The 1.3 meter rack (#0555) is a 25 EIA unit rack. The rack that is delivered as #0555 is the same rack delivered when you order the 7014-S25 rack; the included features can vary. The #0555 is supported, but no longer orderable. 1.13.5 Feature code 0551 rack The 1.8 meter rack (#0551) is a 36 EIA unit rack. The rack that is delivered as #0551 is the same rack delivered when you order the 7014-T00 rack; the included features can vary. Certain features that are delivered as part of the 7014-T00 must be ordered separately with the #0551. 1.13.6 Feature code 0553 rack The 2.0 meter rack (#0553) is a 42 EIA unit rack. The rack that is delivered as #0553 is the same rack delivered when you order the 7014-T42 or B42 rack; the included features can vary. Some features that are delivered as part of the 7014-T42 or B42 must be ordered separately with the #0553. 1.13.7 The ac power distribution unit and rack content For rack models T00 and T42, 12-outlet PDUs are available. These include ac power distribution units #9188 and #7188 and ac Intelligent PDU+ #5889 and #7109. Four PDUs can be mounted vertically in the back of the T00 and T42 racks. See Figure 1-4 on page 28 for the placement of the four vertically mounted PDUs. In the rear of the rack, two additional PDUs can be installed horizontally in the T00 rack and three in the T42 rack. The four vertical mounting locations will be filled first in the T00 and T42 racks. Mounting PDUs horizontally consumes 1U per PDU and reduces the space available for other racked components. When mounting PDUs horizontally, it is best to use fillers in the EIA units occupied by these PDUs to facilitate proper air-flow and ventilation in the rack.
  • 42. 28 IBM Power 720 and 740: Technical Overview and Introduction Figure 1-4 PDU placement and PDU view For detailed power cord requirements and power cord feature codes, see the IBM Power Systems Hardware Information Center at the following website: http://publib.boulder.ibm.com/infocenter/systems/scope/hw/index.jsp The Intelligent PDU+, base option, 1 EIA Unit, Universal, UTG0247 Connector (#5889), the Base/Side Mount Universal PDU (#9188) and the optional, additional, Universal PDU (#7188) and the Intelligent PDU+ options (#7109) support a wide range of country requirements and electrical power specifications. The #5889 and #7109 PDUs are identical to #9188 and #7188 PDUs but are equipped with one Ethernet port, one console serial port, and one rs232 serial port for power monitoring. The PDU receives power through a UTG0247 power line connector. Each PDU requires one PDU-to-wall power cord. Various power cord features are available for various countries and applications by varying the PDU-to-wall power cord, which must be ordered separately. Each power cord provides the unique design characteristics for the specific power requirements. To match new power requirements and save previous investments, these power cords can be requested with an initial order of the rack or with a later upgrade of the rack features. The PDU has 12 client-usable IEC 320-C13 outlets. There are six groups of two outlets fed by six circuit breakers. Each outlet is rated up to 10 amps, but each group of two outlets is fed from one 15 amp circuit breaker. Note: Ensure that the appropriate power cord feature is configured to support the power being supplied.
  • 43. Chapter 1. General description 29 The Universal PDUs are compatible with previous models. 1.13.8 Rack-mounting rules Follow these primary rules when mounting the system into a rack: The system is designed to be placed at any location in the rack. For rack stability, it is advisable to start filling a rack from the bottom. Any remaining space in the rack can be used to install other systems or peripherals, provided that the maximum permissible weight of the rack is not exceeded and the installation rules for these devices are followed. Before placing the system into the service position, it is essential that the rack manufacturer’s safety instructions have been followed regarding rack stability. 1.13.9 Useful rack additions This section highlights solutions available for IBM Power Systems rack-based systems. IBM System Storage 7214 Tape and DVD Enclosure The IBM System Storage® 7214 Tape and DVD Enclosure is designed to mount in one EIA unit of a standard IBM Power Systems 19-inch rack and can be configured with one or two tape drives, or either one or two Slim DVD-RAM or DVD-ROM drives in the right-side bay. The two bays of the IBM System Storage 7214 Tape and DVD Enclosure can accommodate the following tape or DVD drives for IBM Power servers: DAT72 36 GB Tape Drive - up to two drives DAT72 36 GB Tape Drive - up to two drives DAT160 80 GB Tape Drive - up to two drives Half-high LTO Ultrium 4 800 GB Tape Drive - up to two drives DVD-RAM Optical Drive - up to two drives DVD-ROM Optical Drive - up to two drives Note: Based on the power cord that is used, the PDU can supply from 4.8 kVA to 19.2 kVA. The power of all the drawers plugged into the PDU must not exceed the power cord limitation. Note: Each system drawer to be mounted in the rack requires two power cords, which are not included in the base order. For maximum availability, it is highly desirable to connect power cords from the same system to two separate PDUs in the rack, and to connect each PDU to independent power sources.
  • 44. 30 IBM Power 720 and 740: Technical Overview and Introduction IBM System Storage 7216 Multi-Media Enclosure The IBM System Storage 7216 Multi-Media Enclosure (Model 1U2) is designed to attach to the Power 720 and the Power 740 through a USB port on the server, or through a PCIe SAS adapter. The 7216 has two bays to accommodate external tape, removable disk drive, or DVD-RAM drive options. The following optional drive technologies are available for the 7216-1U2: DAT160 80 GB SAS Tape Drive (#5619 DAT320 160 GB SAS Tape Drive (#1402) DAT320 160 GB USB Tape Drive (#5673) Half-high LTO Ultrium 5 1.5 TB SAS Tape Drive (#8247) DVD-RAM - 9.4 GB SAS Slim Optical Drive (#1420 and 1422 RDX Removable Disk Drive Docking Station (#1103) In order to attach a 7216 Multi-Media Enclosure to the Power 720 and Power 740, consider the following cabling procedures: Attachment by an SAS adapter: A PCIe Dual-X4 SAS adapter (#5901) or a PCIe LP 2-x4-port SAS Adapter 3Gb (#5278) must be installed in the Power 720 and Power 740 server in order to attach to a 7216 Model 1U2 Multi-Media Storage Enclosure. Attaching a 7216 to a Power 720 and Power 740 through the integrated SAS adapter is not supported. For each SAS tape drive and DVD-RAM drive feature installed in the 7216, the appropriate external SAS cable will be included. An optional Quad External SAS cable is available by specifying (#5544) with each 7216 order. The Quad External Cable allows up to four 7216 SAS tape or DVD-RAM features to attach to a single System SAS adapter. Up to two 7216 storage enclosure SAS features can be attached per PCIe Dual-X4 SAS adapter (#5901) or the PCIe LP 2-x4-port SAS Adapter 3Gb (#5278). Attachment by an USB adapter: The Removable RDX HDD Docking Station features on 7216 only support the USB cable that is provided as part of the feature code. Additional USB hubs, add-on USB cables, or USB cable extenders are not supported. For each RDX Docking Station feature installed in the 7216, the appropriate external USB cable will be included. The 7216 RDX Docking Station feature can be connected to the external, integrated USB ports on the Power 710 and Power 730 or to the USB ports on 4-Port USB PCI Express® Adapter (# 2728). The 7216 DAT320 USB tape drive or RDX Docking Station features can be connected to the external, integrated USB ports on the Power 710 and Power 730. The two drive slots of the 7216 enclosure can hold the following drive combinations: One tape drive (DAT160 SAS or Half-high LTO Ultrium 5 SAS) with second bay empty Two tape drives (DAT160 SAS or Half-high LTO Ultrium 5 SAS) in any combination One tape drive (DAT160 SAS or Half-high LTO Ultrium 5 SAS) and one DVD-RAM SAS drive sled with one or two DVD-RAM SAS drives Up to four DVD-RAM drives Note: DAT320 160 GB SAS Tape Drive (#1402)and DAT320 160 GB USB Tape Drive (#5673) No Longer Available as of July 15, 2011
  • 45. Chapter 1. General description 31 One tape drive (DAT160 SAS or Half-high LTO Ultrium 5 SAS) in one bay, and one RDX Removable HDD Docking Station in the other drive bay One RDX Removable HDD Docking Station and one DVD-RAM SAS drive sled with one or two DVD-RAM SAS drives in the right bay Two RDX Removable HDD Docking Stations Figure 1-5 shows the 7216 Multi-Media Enclosure. Figure 1-5 7216 Multi-Media Enclosure In general, the 7216-1U2 is supported by the AIX, IBM i, and Linux operating system, however, the RDX Removable Disk Drive Docking Station and the DAT320 USB Tape Drive are not supported with IBM i. Flat panel display options The IBM 7316 Model TF3 is a rack-mountable flat panel console kit consisting of a 17-inch 337.9 mm x 270.3 mm flat panel color monitor, rack keyboard tray, IBM Travel Keyboard, support for IBM's Keyboard/Video/Mouse (KVM) switches, and language support. The IBM 7316-TF3 Flat Panel Console Kit offers the following features: Slim, sleek, lightweight monitor design that occupies only 1U (1.75 inches) in a 19-inch standard rack A 17-inch, flat screen TFT monitor with truly accurate images and virtually no distortion Ability to mount the IBM Travel Keyboard in the 7316-TF3 rack keyboard tray Support for IBM's Keyboard/Video/Mouse (KVM) switches that provide control of as many as 128 servers, and support of both USB and PS/2 server-side keyboard and mouse connections
  • 46. 32 IBM Power 720 and 740: Technical Overview and Introduction 1.13.10 OEM rack The system can be installed in a suitable OEM rack, provided that the rack conforms to the EIA-310-D standard for 19-inch racks. This standard is published by the Electrical Industries Alliance. For detailed information. see the IBM Power Systems Hardware Information Center: http://publib.boulder.ibm.com/infocenter/systems/scope/hw/index.jsp The key points mentioned are as follows: The front rack opening must be 451 mm wide ± 0.75 mm (17.75 in. ± 0.03 in.), and the rail-mounting holes must be 465 mm ± 0.8 mm (18.3 in. ± 0.03 in.) apart on center (horizontal width between the vertical columns of holes on the two front-mounting flanges and on the two rear-mounting flanges). See Figure 1-6 for a top view showing the specification dimensions. Figure 1-6 Top view of non-IBM rack specification dimensions 571mm (22.50 in.) Drawer Rail Mounting Flanges Back, No Door 494mm (19.45 in.) Front, No Door 203mm (8.0 in.) 719mm (28.31 in.) 51mm (2.01 in.) 451mm (17.76 in.) 494mm (19.45 in.)
  • 47. Chapter 1. General description 33 The vertical distance between the mounting holes must consist of sets of three holes spaced (from bottom to top) 15.9 mm (0.625 in.), 15.9 mm (0.625 in.), and 12.67 mm (0.5 in.) on center, making each three-hole set of vertical hole spacing 44.45 mm (1.75 in.) apart on center. Rail-mounting holes must be 7.1 mm ± 0.1 mm (0.28 in. ± 0.004 in.) in diameter. See Figure 1-7 for the top front specification dimensions. Figure 1-7 Rack specification dimensions, top front view Hole Diameter = 7.1 +/- 0.1mm Rack Mounting Holes Center-to-Center Rack Front Opening 450 +/- 0.75mm 465 +/- 0.8mm EIAHoleSpacing 6.75mm min 15.9mm 15.9mm 12.7mm 15.9mm 15.9mm 12.7mm 6.75mm min 15.9mm 15.9mm 12.7mm 15.9mm 15.9mm 12.7mm Top Front of Rack
  • 48. 34 IBM Power 720 and 740: Technical Overview and Introduction
  • 49. © Copyright IBM Corp. 2010. All rights reserved. 35 Chapter 2. Architecture and technical overview This chapter discusses the overall system architecture represented by Figure 2-1 on page 36, with its major components described in the following sections. The bandwidths that are provided throughout the section are theoretical maximums used for reference. The speeds shown are at an individual component level. Multiple components and application implementation are key to achieving the best performance. Always do the performance sizing at the application workload environment level and evaluate performance using real-world performance measurements and production workloads. 2
  • 50. 36 IBM Power 720 and 740: Technical Overview and Introduction Figure 2-1 Power 740 logic data flow POWER7 chip 0 4- 6- or 8-cores Memory controller 0 GX1 DIMM #2 – P1-C18-C2 buffer DIMM #4 – P1-C18-C4 D C B A Integrated Virtual Ethernet ports USB portsUSB ctrl GX++ slot 2 GX++ slot 1 Hard disk 2 Hard disk 3 Hard disk 1 PCIe slot 1 (short) PCIe slot 2 (short) PCIe slot 3 (short) PCIe slot 4 (short) GX++ connector 2 GX++ connector 1 2 HMC ports 2 SPCN ports GX0 Service Processor Operator panel Vital Product Data smart chip DIMM #8 – P1-C18-C10 buffer DIMM #6 – P1-C18-C8 POWER7 chip 1 4- 6- or 8-cores Memory controller 0 D C B A 23.2GBps GX1 GX0 Hard disk 4 Hard disk 5 Hard disk 6 SAS Controller DASD and media backplane DVD Integrated Virtual Ethernet ports RAID Option External SAS Port 2 System ports P5-IOC2 10 GBps 20 GBps 20 GBps DIMM #3 – P1-C18-C3 DIMM #5 – P1-C18-C7 DIMM #1 – P1-C18-C1 DIMM #7 – P1-C18-C9 MemoryCard#1 DIMM #2 – P1-C17-C2 buffer DIMM #4 – P1-C17-C4 DIMM #8 – P1-C17-C10buffer DIMM #6 – P1-C17-C8 DIMM #3 – P1-C17-C3 DIMM #5 – P1-C17-C7 DIMM #1 – P1-C17-C1 DIMM #7 – P1-C17-C9 MemoryCard#2 DIMM #2 – P1-C16-C2 buffer DIMM #4 – P1-C16-C4 DIMM #8 – P1-C16-C10 buffer DIMM #6 – P1-C16-C8 DIMM #3 – P1-C16-C3 DIMM #5 – P1-C16-C7 DIMM #1 – P1-C16-C1 DIMM #7 – P1-C16-C9 MemoryCard#3 DIMM #2 – P1-C15-C2 buffer DIMM #4 – P1-C15-C4 DIMM #8 – P1-C15-C10 buffer DIMM #6 – P1-C15-C8 DIMM #3 – P1-C15-C3 DIMM #5 – P1-C15-C7 DIMM #1 – P1-C15-C1 DIMM #7 – P1-C15-C9 MemoryCard#4 PCIe slot 1 (short, LP) PCIe slot 2 (short, LP) PCIe slot 3 (short, LP) PCIe slot 4 (short, LP) P5-IOC2 (Optional internal PCIe expansion) 23.2GBps 23.2GBps
  • 51. Chapter 2. Architecture and technical overview 37 2.1 The IBM POWER7 processor The IBM POWER7 processor represents a leap forward in technology achievement and associated computing capability. The multi-core architecture of the POWER7 processor has been matched with innovation across a wide range of related technologies in order to deliver leading throughput, efficiency, scalability, and RAS. Although the processor is an important component in delivering outstanding servers, many elements and facilities have to be balanced on a server in order to deliver maximum throughput. As with previous generations of systems based on POWER processors, the design philosophy for POWER7 processor-based systems is one of system-wide balance in which the POWER7 processor plays an important role. In many cases, IBM has been innovative in order to achieve required levels of throughput and bandwidth. Areas of innovation for the POWER7 processor and POWER7 processor-based systems include, but are not limited to, the following features: On-chip L3 cache implemented in embedded dynamic random access memory (eDRAM) Cache hierarchy and component innovation Advances in memory subsystem Advances in off-chip signalling Exploitation of long-term investment in coherence innovation The superscalar POWER7 processor design also provides a variety of other capabilities: Binary compatibility with the prior generation of POWER processors Support for PowerVM virtualization capabilities, including PowerVM Live Partition Mobility to and from POWER6 and POWER6+ processor-based systems.
  • 52. 38 IBM Power 720 and 740: Technical Overview and Introduction Figure 2-2 shows the POWER7 processor die layout with the major areas identified; processor cores, L2 cache, L3 cache and chip interconnection, Symmetric Multi Processing (SMP) links, and memory controllers. Figure 2-2 POWER7 processor die with key areas indicated 2.1.1 POWER7 processor overview The POWER7 processor chip is fabricated using the IBM 45 nm Silicon-On-Insulator (SOI) technology using copper interconnect and implements an on-chip L3 cache using eDRAM. The POWER7 processor chip has an area of 567 mm2 and is built using 1.2 billion components (transistors). Eight processor cores are on the chip, each with 12 execution units, 256 KB of L2 cache, and access to 32 MB of shared on-chip L3 cache. For memory access, the POWER7 processor includes two Double Data Rate 3 (DDR3) memory controllers, each with four memory channels. To be able to scale effectively, the POWER7 processor uses a combination of local and global SMP links with very high coherency bandwidth and takes advantage of the IBM dual-scope broadcast coherence protocol.
  • 53. Chapter 2. Architecture and technical overview 39 Table 2-1 summarizes the technology characteristics of the POWER7 processor. Table 2-1 Summary of POWER7 processor technology 2.1.2 POWER7 processor core Each POWER7 processor core implements aggressive out-of-order (OoO) instruction execution to drive high efficiency in the use of available execution paths. The POWER7 processor has an Instruction Sequence Unit that is capable of dispatching up to six instructions per cycle to a set of queues. Up to eight instructions per cycle can be issued to the Instruction Execution units. The POWER7 processor has a set of twelve execution units: 2 fixed point units 2 load store units 4 double precision floating point units 1 vector unit 1 branch unit 1 condition register unit 1 decimal floating point unit The following caches are tightly coupled to each POWER7 processor core: Instruction cache: 32 KB Data cache: 32 KB L2 cache: 256 KB, implemented in fast SRAM Technology POWER7 processor Die size 567 mm2 Fabrication technology 45 nm lithography Copper interconnect Silicon-on-Insulator eDRAM Components 1.2 billion components/transistors offering the equivalent function of 2.7 billion (for further details, see 2.1.6, “On-chip L3 cache innovation and Intelligent Cache” on page 43) Processor cores 8 Max execution threads per core/chip 4/32 L2 cache per core/chip 256 KB/2 MB On-chip L3 cache per core/chip 4 MB/32 MB DDR3 memory controllers 2 SMP design-point 32 sockets with IBM POWER7 processors Compatibility With prior generation of POWER processor
  • 54. 40 IBM Power 720 and 740: Technical Overview and Introduction 2.1.3 Simultaneous multithreading An enhancement in the POWER7 processor is the addition of the SMT4 mode to enable four instruction threads to execute simultaneously in each POWER7 processor core. Thus, the instruction thread execution modes of the POWER7 processor are as follows: SMT1: Single instruction execution thread per core SMT2: Two instruction execution threads per core SMT4: Four instruction execution threads per core Maximizing throughput SMT4 mode enables the POWER7 processor to maximize the throughput of the processor core by offering an increase in core efficiency. SMT4 mode is the latest step in an evolution of multithreading technologies introduced by IBM. The diagram in Figure 2-3 shows the evolution of simultaneous multithreading. Figure 2-3 Evolution of simultaneous multi-threading The various SMT modes offered by the POWER7 processor allow flexibility, enabling users to select the threading mode that meets an aggregation of objectives such as performance, throughput, energy use, and workload enablement. Intelligent Threads The POWER7 processor features Intelligent Threads that can vary based on the workload demand. The system either automatically selects (or the system administrator can manually select) whether a workload benefits from dedicating as much capability as possible to a single thread of work, or if the workload benefits more from having capability spread across two or four threads of work. With more threads, the POWER7 processor can deliver more total capacity as more tasks are accomplished in parallel. With fewer threads, those workloads that need very fast individual tasks can get the performance they need for maximum benefit. Multi-threading Evolution FX0 FX1 FP0 FP1 LS0 LS1 BRX CRL 1995 Single thread out of order FX0 FX1 FP0 FP1 LS0 LS1 BRX CRL 1997 Hardware multi-thread FX0 FX1 FP0 FP1 LS0 LS1 BRX CRL 2003 2 Way SMT FX0 FX1 FP0 FP1 LS0 LS1 BRX CRL 2009 4 Way SMT
  • 55. Chapter 2. Architecture and technical overview 41 2.1.4 Memory access Each POWER7 processor chip has two DDR3 memory controllers, each with four memory channels (enabling eight memory channels per POWER7 processor chip). Each channel operates at 6.4 GHz and can address up to 32 GB of memory. Thus, each POWER7 processor chip is capable of addressing up to 256 GB of memory. Figure 2-4 gives a simple overview of the POWER7 processor memory access structure. Figure 2-4 Overview of POWER7 memory access structure 2.1.5 Flexible POWER7 processor packaging and offerings The POWER7 processor forms the basis of a flexible compute platform and can be offered in a number of guises to address differing system requirements. The POWER7 processor can be offered with a single active memory controller with four channels for servers where higher degrees of memory parallelism are not required. Similarly, the POWER7 processor can be offered with a variety of SMP bus capacities that are appropriate to the scaling-point of particular server models. POWER7 Processor Chip Advanced Buffer ASIC Chip Memory Controller Advanced Buffer ASIC Chip Memory Controller Core Core Core Core Core Core Core Core Dual Integrated DDR3 memory controllers • High channel and DIMM utilization • Advanced energy management • RAS advances Eight high-speed 6.4 GHz channels • New low-power differential signalling New DDR3 buffer chip architecture • Larger capacity support (32 GB/core) • Energy management support • RAS enablement DDR3 DRAMs
  • 56. 42 IBM Power 720 and 740: Technical Overview and Introduction Figure 2-5 outlines the physical packaging options that are supported with POWER7 processors. Figure 2-5 Outline of the POWER7 processor physical packaging POWER7 processors have the unique ability to optimize to various workload types. For example, database workloads typically benefit from very fast processors that handle high transaction rates at high speeds. Web workloads typically benefit more from processors with many threads that allow the breaking down of web requests into many parts and handle them in parallel. POWER7 processors uniquely have the ability to provide leadership performance in either case. TurboCore mode Users can choose to run selected servers in TurboCore mode. This mode uses four cores per POWER7 processor chip with access to the entire 32 MB of L3 cache (8 MB per core) and at a faster processor core frequency, which delivers higher performance per core, and might save on software costs for those applications that are licensed per core. MaxCore mode MaxCore mode is for workloads that benefit from a higher number of cores and threads handling multiple tasks simultaneously, taking advantage of increased parallelism. MaxCore mode provides up to eight cores and up to 32 threads per POWER7 processor. POWER7 processor 4-core and 6-core offerings The base design for the POWER7 processor is an 8-core processor with 32 MB of on-chip L3 cache (4 MB per core). However, the architecture allows for differing numbers of processor cores to be active; 4-cores or 6-cores, as well as the full 8-core version. In most cases (MaxCore mode), the L3 cache associated with the implementation is dependent on the number of active cores. For a 6-core version, this typically means that 6 x 4 MB (24 MB) of L3 cache is available. Similarly, for a 4-core version, the L3 cache available is 16 MB. Note: TurboCore is available on the Power 780 and Power 795. Single Chip Organic 1 x Memory Controller Local broadcast SMP links active Single Chip Glass Ceramic 2 x Memory Controllers Local broadcast SMP links active Global broadcast SMP links active
  • 57. Chapter 2. Architecture and technical overview 43 2.1.6 On-chip L3 cache innovation and Intelligent Cache A breakthrough in material engineering and microprocessor fabrication has enabled IBM to implement the L3 cache in eDRAM and place it on the POWER7 processor die. L3 cache is critical to a balanced design, as is the ability to provide good signalling between the L3 cache and other elements of the hierarchy such as the L2 cache or SMP interconnect. The on-chip L3 cache is organized into separate areas with differing latency characteristics. Each processor core is associated with a Fast Local Region of L3 cache (FLR-L3) but also has access to other L3 cache regions as shared L3 cache. Additionally, each core can negotiate to use the FLR-L3 cache associated with another core, depending on reference patterns. Data can also be cloned to be stored in more than one core's FLR-L3 cache, again depending on reference patterns. This Intelligent Cache management enables the POWER7 processor to optimize the access to L3 cache lines and minimize overall cache latencies. Figure 2-6 shows the FLR-L3 cache regions for each of the cores on the POWER7 processor die. Figure 2-6 Fast local regions of L3 cache on the POWER7 processor Innovation using eDRAM on the POWER7 processor die is significant for these reasons: Latency improvement: A six-to-one latency improvement occurs by moving the L3 cache on-chip compared to L3 accesses on an external (on-ceramic) ASIC. Bandwidth improvement: A 2x bandwidth improvement occurs with on-chip interconnect. Frequency and bus sizes are increased to and from each core.
  • 58. 44 IBM Power 720 and 740: Technical Overview and Introduction No off-chip driver or receivers: Removing drivers or receivers from the L3 access path lowers interface requirements, conserves energy, and lowers latency. Small physical footprint: The eDRAM L3 cache requires far less physical space than an equivalent L3 cache implemented with conventional SRAM. IBM on-chip eDRAM uses only a third of the components used in conventional SRAM which has a minimum of 6 transistors to implement a 1-bit memory cell. Low energy consumption: The on-chip eDRAM uses only 20% of the standby power of SRAM. 2.1.7 POWER7 processor and Intelligent Energy Energy consumption is an important area of focus for the design of the POWER7 processor which includes Intelligent Energy features that help to dynamically optimize energy usage and performance so that the best possible balance is maintained. Intelligent Energy features such as EnergyScale work with IBM Systems Director Active Energy Manager™ to dynamically optimize processor speed based on thermal conditions and system utilization. 2.1.8 Comparison of the POWER7 and POWER6 processors Table 2-2 shows comparable characteristics between the generations of POWER7 and POWER6 processors. Table 2-2 Comparison of technology for the POWER7 processor and the prior generation Feature POWER7 POWER6 Technology 45 nm 65 nm Die size 567 mm2 341 mm2 Maximum cores 8 2 Maximum SMT threads per core 4 threads 2 threads Maximum frequency 4.25 GHz 5 GHz L2 Cache 256 KB per core 4 MB per core L3 Cache 4 MB of FLR-L3 cache per core with each core having access to the full 32 MB of L3 cache, on-chip eDRAM 32 MB off-chip eDRAM ASIC Memory support DDR3 DDR2 I/O Bus Two GX++ One GX++ Enhanced Cache Mode (TurboCore) Yes No Sleep & Nap Modea a. For more information about Sleep and Nap modes, see 2.18.1, “IBM EnergyScale technology” on page 96. Both Nap only
  • 59. Chapter 2. Architecture and technical overview 45 2.2 POWER7 processor modules The Power 720 and Power 740 server chassis house POWER7 processor modules that host POWER7 processor sockets (SCM) and eight DDR3 memory DIMM slots for each processor module. The Power 720 server houses one processor module offering 4-core 3.0 GHz, 6-core 3.0 GHz, or 8-core 3.0 GHz configurations. The Power 740 server houses one or two processor modules offering 4-core or 8-core 3.3 and 3.7 GHz, 6-core or 12-core 3.7 GHz, or 8- and 16-core 3.55 GHz configurations. All off the installed processors must be activated. 2.2.1 Modules and cards Figure 2-7 shows the system planar highlighting the POWER7 processor modules and the memory riser cards. Figure 2-7 POWER7 processor card shown in a Power 740 with processor module Note: All POWER7 processors in the system must be the same frequency and have the same number of processor cores. POWER7 processor types cannot be mixed within a system. Memory riser cards POWER7 processor modules
  • 60. 46 IBM Power 720 and 740: Technical Overview and Introduction 2.2.2 Power 720 and Power 740 systems Power 720 and Power 740 systems support POWER7 processors with various core-counts. Table 2-3 summarizes the POWER7 processor options for the Power 720 system. Table 2-3 Summary of POWER7 processor options for the Power 720 system Table 2-4 summarizes the POWER7 processor options for the Power 740 system. Table 2-4 Summary of POWER7 processor options for the Power 740 system Feature Cores per POWER7 processor Frequency (GHz) Processor activation Min/Max cores per system Min/Max processor module #8350 4 3.0 The 4-core 3.0 GHz requires that four processor activation codes are ordered, available as 4 x #8360 or 2 x #8360 and 2 x #8363 4/4 1/1 #8351 6 3.0 The 6-core 3.0 GHz requires that six processor activation codes be ordered, available as 6 x #8361 or 3 x #8361 and 3 x #8364 6/6 1/1 #8352 8 3.0 The 8-core 3.0 GHz requires that eight processor activation codes be ordered, available as 8 x #8362 or 4 x #8362 and 4 x #8365 8/8 1/1 Feature Cores per POWER7 processor Frequency (GHz) Processor activation Min/Max cores per system Min/Max processor module #8353 4 3.3 The 4-core 3.3 GHz requires that four processor activation codes are ordered, available as 4 x #8366 or 2 x #8366 and 2 x #8369 4/8 1/2 #8347 4 3.7 The 4-core 3.7 GHz requires that four processor activation codes are ordered, available as 4 x #8373 or 2 x #8373 and 2 x #8374 4/8 1/2 #8354 6 3.7 The 6-core 3.7 GHz requires that six processor activation codes are ordered, available as 6 x #8367 or 3 x #8367 and 3 x #8370 6/12 1/2 #8355 8 3.55 2 x of the 8 core 3.55 GHz requires that 16 processor activation codes are ordered, available as 16 x #8368 or 8 x #8368 and 8 x#8371) 16 1/2
  • 61. Chapter 2. Architecture and technical overview 47 2.3 Memory subsystem The Power 720 is a one socket system supporting a single POWER7 processor module. The server supports a maximum of 16 DDR3 DIMM slots, with eight DIMM slots included in the base configuration and eight DIMM slots available with an optional memory riser card. Memory features (two memory DIMMs per feature) supported are 8 GB and 16 GB running at speeds of 1066 MHz. A system with the optional memory riser card installed has a maximum memory of 128 GB. The Power 740 is a two socket system supporting up to two POWER7 processor modules. The server supports a maximum of 32 DDR3 DIMM slots, with 8 DIMM slots included in the base configuration and 24 DIMM slots available with three optional memory riser cards. Memory features (two memory DIMMs per feature) supported are 8 GB and 16 GB run at speeds of 1066 MHz. A system with three optional memory riser cards installed has a maximum memory of 256 GB. 2.3.1 Registered DIMM Industry standard DDR3 Registered DIMM (RDIMM) technology is used to increase reliability, speed, and density of memory subsystems. 2.3.2 Memory placement rules The following memory options are orderable: 8 GB (2 x 4 GB) Memory DIMMs, 1066 MHz (#4526) 16 GB (2 x 8 GB) Memory DIMMs, 1066 MHz (#4529) The minimum memory capacity for the Power 720 and Power 740 systems is 8 GB (2 x 4 GB DIMMs). The maximum is memory supported on the Power 720 is shown in Table 2-5 and the maximum memory supported on the Power 740 is shown in Table 2-6. Table 2-5 Power 720 maximum memory Table 2-6 Power 740 maximum memory Processor cores One memory riser card Two memory riser cards 4-core 32 GB 64 GB 6-core 8-core 64 GB 128 GB Note: A system with the 4-core processor module (#8350) does not support the 16 GB memory feature #4529. Processor cores One memory riser card Two memory riser cards Three memory riser cards Four memory riser cards 1 x 4-core 1 x 6-core 1 x 8-core 64 GB 128 GB Not available Not available 2 x 4-core 2 x 6-core 2 x 8-core 64 GB 128 GB 192 GB 256 GB
  • 62. 48 IBM Power 720 and 740: Technical Overview and Introduction Figure 2-8 shows the physical memory DIMM topology for the POWER7 processor card. Figure 2-8 Memory DIMM topology for the Power 740 The memory-placement rules are as follows: The base machine contains one memory riser card with eight DIMM sockets. Memory features occupy two memory DIMM sockets. One additional memory riser card feature (1 x #5604) with an additional eight DIMM sockets is available when one processor module is installed in the system. For the Power 740, three optional memory riser card features (3 x #5604) with an additional eight DIMM sockets per feature are available when two processor modules are installed in the system. A system can be ordered with a single memory feature #4526. When adding additional memory to a system with 1 x #4526, a second 1 x #4526 must be ordered, and then all memory must be ordered in increments of 2 x #4526. A system cannot be ordered with a single memory feature #4529. All #4529 memory must be ordered in quantity of 2 x feature #4529. Feature #4526 and feature #4529 are allowed on the same memory riser card as long as memory DIMMs are installed in quads (2 x #4526 or 2 x #4529). Note: DDR2 memory (used in POWER6 processor-based systems) is not supported in POWER7 processor-based systems. Memory Card #1 DDR3 RDIMM Slot 2 DDR3 RDIMM Slot 4Port A SN-A Port B DDR3 RDIMM Slot 1 DDR3 RDIMM Slot 3Port A SN-B Port B DDR3 RDIMM Slot 2 DDR3 RDIMM Slot 4Port A SN-C Port B DDR3 RDIMM Slot 1 DDR3 RDIMM Slot 3Port A SN-D Port B Memory Card #2 POWER7 MC0 Port 0 MC0 Port 1 MC0 Port 2 MC0 Port 3 Memory Card #3 DDR3 RDIMM Slot 2 DDR3 RDIMM Slot 4Port A SN-A Port B DDR3 RDIMM Slot 1 DDR3 RDIMM Slot 3Port A SN-B Port B DDR3 RDIMM Slot 2 DDR3 RDIMM Slot 4Port A SN-C Port B DDR3 RDIMM Slot 1 DDR3 RDIMM Slot 3Port A SN-D Port B Memory Card #4 POWER7 MC0 Port 0 MC0 Port 1 MC0 Port 2 MC0 Port 3 MC: Memory Controller SN: Memory Buffer
  • 63. Chapter 2. Architecture and technical overview 49 It is generally best to install memory evenly across all memory riser cards in the system. Balancing memory across the installed memory riser cards allows memory access in a consistent manner and typically results in the best possible performance for your configuration. However, balancing memory fairly evenly across multiple memory riser cards, compared to balancing memory exactly evenly, typically has a very small performance difference. Take into account any plans for future memory upgrades when deciding which memory feature size to use at the time of initial system order. Table 2-7 shows the installation slots for memory DIMMs for two POWER7 modules and four memory cards. Table 2-7 Memory DIMM installation sequence and slots DIMM-pair Memory card DIMM slots First One Slot 6 (P1-C18-C8) Slot 8 (P1-C18-C10) Second One Slot 5 (P1-C18-C7) Slot 7 (P1-C18-C9) Third Fourth Two Slot 5 (P1-C17-C7) Slot 6 (P1-C17-C8) Slot 7 (P1-C17-C9) Slot 8 (P1-C17-C10) Fifth Sixth Three Slot 5 (P1-C16-C7) Slot 6 (P1-C16-C8) Slot 7 (P1-C16-C9) Slot 8 (P1-C16-C10) Seventh Eighth Four Slot 5 (P1-C15-C7) Slot 6 (P1-C15-C8) Slot 7 (P1-C15-C9) Slot 8 (P1-C15-C10) Ninth Tenth One Slot 1 (P1-C18-C1) Slot 2 (P1-C18-C2) Slot 3 (P1-C18-C3) Slot 4 (P1-C18-C4) Eleventh Twelfth Two Slot 1 (P1-C17-C1) Slot 2 (P1-C17-C2) Slot 3 (P1-C17-C3) Slot 4 (P1-C17-C4) Thirteenth Fourteenth Three Slot 1 (P1-C16-C1) Slot 2 (P1-C16-C2) Slot 3 (P1-C16-C3) Slot 4 (P1-C16-C4) Fifteenth Sixteenth Four Slot 1 (P1-C15-C1) Slot 2 (P1-C15-C2) Slot 3 (P1-C15-C3) Slot 4 (P1-C15-C4)
  • 64. 50 IBM Power 720 and 740: Technical Overview and Introduction 2.3.3 Memory bandwidth The POWER7 processor has exceptional cache, memory, and interconnect bandwidths. Table 2-8 shows the bandwidth?? estimates for the Power 720 and Power 740 systems. Table 2-8 Power 720 and Power 740 memory and I/O bandwidth estimates 2.4 Capacity on Demand Capacity on Demand is not supported on the Power 720 and Power 740 systems. 2.5 Factory deconfiguration of processor cores The Power 720 and Power 740 servers have the capability to be shipped with part of the installed cores deconfigured at the factory. The primary use for this feature is to assist with optimization of software licensing. A deconfigured core is unavailable for use in the system and thus does not require software licensing. Feature #2319 deconfigures one core in a Power 720 or Power 740 systems. It is available in a Power 720 with either 4-core, 6-core, or 8-core configurations and in a Power 740 with 12- or 16-core configurations. The maximum number of this feature that can be ordered is one less than the number of cores in the system. For example a maximum of 5 x #2319 can be ordered for a 6-core system. Feature #2319 can only be specified at initial order and cannot be applied to an installed machine. Notes: Only the 8 GB Feature #4526 (2 x 4 GB DIMM) can be installed as a single feature in DIMM pairs, and only for the first two memory features installed. All subsequent memory features must be installed in quads (2 x feature). DIMMs on a given memory card can differ from DIMMs on other memory cards. DIMMs at Slot 1, 2, 3 & 4 on the same memory card must be identical. However, they can differ from the four DIMMs at Slot 5, 6, 7 & 8 on the same memory card. Memory Bandwidth at processor core frequencies 3.0 GHz 3.3 GHz 3.55 GHz 3.72 GHz L1 (data) cache 144 GB/s 158.4 GB/s 170.4 GB/s 178.56 GB/s L2 cache 144 GB/s 158.4 GB/s 170.4 GB/s 178.56 GB/s L3 cache 96 GB/s 105.6 GB/s 113.6 GB/s 119.04 GB/s System memory 68.22 GB/s per socket 68.22 GB/s per socket 68.22 GB/s per socket 68.22 GB/s per socket Note: All processor cores MUST have activations ordered for them. Even the ones being deconfigured.
  • 65. Chapter 2. Architecture and technical overview 51 2.6 Technical comparison of Power 720 and Power 740 Table 2-9 shows a comparison of the technical aspects of the two systems, the Power 720 and the Power 740. Table 2-9 Comparison of technical characteristics between Power 720 and Power 740 2.7 System bus This section provides additional information related to the internal buses. System characteristics Power 720 Power 740 Processor modules 4-core 3.0 GHz POWER7 6-core 3.0 GHz POWER7 8-core 3.0 GHz POWER7 4-core 3.3 GHz POWER7 4-core 3.7 GHz POWER7 6-core 3.7 GHz POWER7 8-core 3.55 GHz POWER7 Pluggable processor modules 1 only 1 or 2 Min./Max. processor cores 4/8 4/8 (4-core modules) 6/12 (6-core modules) 16/16 (8-core modules) L3 cache on-chip eDRAM on-chip eDRAM Max memory slots and type 8 slots per memory riser card, (16 slots max.), DDR3 at 1066 MHz 8 slots per memory riser card, (32 slots max.), DDR3 at 1066 MHz Memory chipkill Yes Yes Memory spare No No Memory hotplug No No TPMD card Yes Yes PCIe x8 slots (in chassis) 8 4 full-height/short cards 4 low-profile/short cards (optional) 8 4 full-height/short cards 4 low-profile/short cards (optional) PCI-X 2.0 slots in chassis n/a n/a PCIe and PCI-X hot plug No No PowerVM support Yes Yes Capacity on Demand No No Redundant hotplug power Optional Yes DASD bays (hot-plug, front access, SFF) 6 or 8 6 or 8 GX++ slots 1 2
  • 66. 52 IBM Power 720 and 740: Technical Overview and Introduction The Power 720 and 740 systems have internal I/O connectivity through PCIe slots, as well as external connectivity through Infiniband adapters. The internal I/O subsystem on the Power 720 and 740 is connected to the GX bus on a POWER7 processor in the system. This bus runs at 1.25 GHz and provides 10 GB/s of I/O connectivity to the PCIe slots, IVE ports, SAS internal adapters and USB ports. Additionally, the POWER7 processor chip installed on the Power 720, and each of the processor chips on the Power 740 provide a GX++ bus which is used to optionally connect to a 12x GX++ adapter. Each bus runs at 2.5 GHz and provides 20 GB/s bandwidth. The slot associated with the first processor socket supports the Dual port 12x channel attach (#5615) Feature for external I/O drawer accessibility. This slot also supports the PCIe Adapter Riser Card (#5610).This adapter connects an additional multifunctional host bridge chip to the first processor, which enables 4 additional PCIe slots. One GX++ slot is available on the Power 720 and two GX++ slots are available on the Power 740. The GX++ Dual-port 12x Channel Attach Adapter (#5615) can be installed in either GX++ slots. The first GX++ slot can also be used by the optional PCIe Adapter Riser Card feature (#5610) to add four short, 8x, PICe low profile slots. Table 2-10 provides I/O bandwidth of Power 720 and 740 processors configuration (review). Table 2-10 I/O bandwidth 2.8 Internal I/O subsystem The internal I/O subsystem resides on the system planar which support PCIe slot. PCIe slots on the Power 720 and 740 are not hot pluggable. PCIe and PCI-X slots on the I/O drawers are hot-pluggable. All PCIe slots support Enhanced Error Handling (EEH). PCI EEH-enabled adapters respond to a special data packet generated from the affected PCIe slot hardware by calling system firmware, which will examine the affected bus, allow the device driver to reset it, and continue without a system reboot. For Linux, EEH support extends to the majority of frequently used devices, although various third-party PCI devices might not provide native EEH support. An optional PCIe Adapter Riser Card (#5610) adds four short, 8x, PICe Low Profile slots and is installed in a GX++ slot 1. All PCIe slots are EEH but not hot pluggable. 2.8.1 Slot configuration Table 2-11 on page 53 describes the slot configuration of the Power 720 and Power 740. Note: Neither GX++ slots support hot plug. I/O Bandwidth GX++ Bus 20 GB/sec (one on the Power 720, two on the Power 740) GX+ Bus 10 GB/sec (Internal I/O) Total I/O 30 GB/sec for Power 720 50 GB/sec for Power 740
  • 67. Chapter 2. Architecture and technical overview 53 Table 2-11 Slot configuration of a Power 720 and Power 740. 2.8.2 System ports The system planar has two serial ports that are called system ports. When an HMC is connected to the system, the integrated system ports are rendered nonfunctional. In this case, you must install an asynchronous adapter, which is described in Table 2-22 on page 62 for serial port usage: Integrated system ports are not supported under AIX or Linux when the HMC ports are connected to an HMC. Either the HMC ports or the integrated system ports can be used, but not both. The integrated system ports are supported for modem and asynchronous terminal connections. Any other application using serial ports requires a serial port adapter to be installed in a PCI slot. The integrated system ports do not support IBM PowerHA™ configurations. Configuration of the two integrated system ports, including basic port settings (baud rate, and so on), modem selection, call-home and call-in policy, can be performed with the Advanced Systems Management Interface (ASMI). 2.9 Integrated Virtual Ethernet adapter The POWER7 processor-based servers extend the virtualization technologies introduced in POWER5 by offering the Integrated Virtual Ethernet adapter (IVE). IVE, also sometimes named Host Ethernet Adapter (HEA), enables an easy way to manage the sharing of the integrated high-speed Ethernet adapter ports. Slot# Description Location code PCI Host Bridge (PHB) Max. card size Slot 1 PCIe x8 P1-C4 PCIe PHB0 Full-height/short Slot 2 PCIe x8 P1-C5 PCIe PHB1 Full-height/short Slot 3 PCIe x8 P1-C6 PCIe PHB2 Full-height/short Slot 4 PCIe x8 P1-C7 PCIe PHB3 Full-height/short Slot 5a a. Slot 5 to 8 reside on PCIe Adapter Riser Card PCIe x8 P1-C1-C1 PCIe PHB3 Low Profile/short Slot 6 PCIe x8 P1-C1-C2 PCIe PHB0 Low Profile/short Slot 7 PCIe x8 P1-C1-C3 PCIe PHB2 Low Profile/short Slot 8 PCIe x8 P1-C1-C4 PCIe PHB1 Low Profile/short Note: Full-height PCIe adapters and low profile PCIe adapters are not interchangeable. Even if the card was designed with low profile dimensions, the tail stock at the end of the adapter is specific to either low profile or full height PCIe slots. Note: The integrated console/modem port usage just described is for systems configured as a single, system wide partition. When it is configured with multiple partitions, the integrated console/modem ports are disabled because the TTY console and call home functions are performed with the HMC.
  • 68. 54 IBM Power 720 and 740: Technical Overview and Introduction There are various Integrated Virtual Ethernet adapter card options: #1824 Quad-port 1 Gb HEA Daughter Card (Copper) #1825 Dual-port 10 Gb HEA Daughter Card (Fiber) #1826 Dual-port 10 Gb HEA Daughter Card (Copper) The IVE includes special hardware features to provide logical Ethernet ports that can communicate to logical partitions (LPAR) reducing the use of IBM POWER Hypervisor™ (PHYP). Its design provides a direct connection for multiple LPARs, allowing LPARs to access external networks through the IVE without having to go through an Ethernet bridge on another logical partition, such as a the Virtual I/O Server. Therefore, this eliminates the need to move packets (using Virtual Ethernet Adapters) between partitions and then through a Shared Ethernet Adapter (SEA) to an physical Ethernet port. LPARs can share IVE ports with improved performance. 2.9.1 IVE and SEA implementations Figure 2-9 shows the difference between IVE and SEA implementations. Figure 2-9 Integrated Virtual Ethernet compared to Virtual I/O Server Shared Ethernet Adapter The IVE design provides high performance Ethernet with efficient virtualization. It offers: Either four 1 Gbps (#1832) or two 10 Gbps ports (#1833 - Fiber or #1837 - Copper) External network connectivity for LPARs using dedicated ports without the need of a Virtual I/O Server Industry standard hardware acceleration, with flexible configuration possibilities The speed and performance of the GX+ bus Great improvement of latency for short packets that are ideal for messaging applications such as distributed databases that require low latency communication for synchronization and short transactions Hypervisor AIXHosting Partition AIX Linux Virtual Ethernet Switch Virtual Ethernet Driver Virtual Ethernet Driver Virtual Ethernet Driver Network Adapters Packet Forwarder LAN, WAN, ... AIX AIX Linux Using Virtual I/O Server Shared Ethernet Adapter Using Integrated Virtual Ethernet Virtual Ethernet Driver Virtual Ethernet Driver Virtual Ethernet Driver Integrated Virtual Ethernet
  • 69. Chapter 2. Architecture and technical overview 55 Table 2-12 lists the various IVE options available on the Power 720 and 740 systems. Table 2-12 IVE options on the Power 720 and 740 For more information about IVE features read Integrated Virtual Ethernet Adapter Technical Overview and Introduction, REDP-4340. 2.9.2 IVE subsystem One of the key design goals of the IVE is the capability to integrate up to two 10 Gbps Ethernet ports or four 1 Gbps Ethernet ports into the P5IOC2 chip, with the effect of a low cost Ethernet solution for low-end and mid-range server platforms. Each IVE can provide 32 logical ports to client partitions on the server. The quad-port 1 Gb adapter supports up to eight logical ports per physical port. The two dual-port 10 Gb adapters support up to 16 logical ports per physical port. If the IVE card is replaced, then a new IVE card provides a new set of MAC addresses. The IVE does not have flash memory for its open firmware but it is stored in the Service Processor flash and then passed to POWER Hypervisor control. Therefore, flash code update is done by the POWER Hypervisor. 2.10 PCI adapters Peripheral Component Interconnect Express (PCIe) uses a serial interface and allows for point-to-point interconnections between devices using directly wired interface between these connection points. A single PCIe serial link is a dual-simplex connection using two pairs of wires, one pair for transmit and one pair for receive, and can only transmit one bit per cycle. It can transmit at the extremely high speed of 2.5 Gbps, which equates to a burst mode of 320 MBps on a single connection. These two pairs of wires are called a lane. A PCIe link can be composed of multiple lanes. In such configurations, the connection is labeled as x1, x2, x8, x12, x16 or x32, where the number is effectively the number of lanes. All adapters support Extended Error Handling (EEH); PCIe adapters use another type of slot than PCI and PCI-X adapters. If you attempt to force an adapter into the wrong type of slot, you might damage the adapter or the slot. A PCI adapter can be installed in a PCI-X slot, and a PCI-X adapter can be installed in a PCI adapter slot. A PCIe adapter cannot be installed in a PCI or PCI-X adapter slot, and a PCI or PCI-X adapter cannot be installed in a PCIe slot. Before adding or rearranging adapters, use the System Planning Tool to validate the new adapter configuration. See the System Planning Tool website: http://www.ibm.com/systems/support/tools/systemplanningtool/ Feature Code Description #1824 Quad-port 1 Gb HEA Daughter Card (Copper) #1825 Dual-port 10 Gb HEA Daughter Card (Fiber) #1826 Dual-port 10 Gb HEA Daughter Card (Copper) Note: IBM i IOPs are not supported.
  • 70. 56 IBM Power 720 and 740: Technical Overview and Introduction If you are installing a new feature, ensure that you have the software required to support the new feature and determine whether there are any existing PTF prerequisites to install. To do this, use the IBM Prerequisite website: https://www-912.ibm.com/e_dir/eServerPreReq.nsf The following sections discuss the supported adapters under various classifications (LAN, SCSI, SAS, Fibre Channel (FC), and so forth) and provide tables of orderable feature numbers. The tables indicate that the feature is supported by the AIX (A), IBM i (i), and Linux (L) operating systems. 2.10.1 LAN adapters To connect to a local area network (LAN), you can use Integrated Virtual Ethernet. Other LAN adapters are supported in the system enclosure PCIe slots or in I/O enclosures that are attached to the system using a 12X technology loop. Table 2-13 lists the additional LAN adapters that are available. Table 2-13 Available LAN adapters Feature code Adapter description Slot Size OS support 5271 PCIe LP 4-Port 10/100/1000 Base-TX Ethernet Adapter PCIe Low profile Short A, L 5272 PCIe LP 10GbE CX4 1-port Adapter PCIe Low profile Short A, L 5274 PCIe LP 2-Port 1GbE SX Adapter PCIe Low profile Short A, i, L 5275 PCIe LP 10GbE SR 1-port Adapter PCIe Low profile Short A, L 5706 IBM 2-Port 10/100/1000 Base-TX Ethernet PCI-X Adapter PCI-X Full-height Short A, i, L 5717 4-Port 10/100/1000 Base-TX PCI Express Adapter PCIe Full-height Short A, L 5732 10 Gigabit Ethernet-CX4 PCI Express Adapter PCIe Full-height Short A, L 5740 4-Port 10/100/1000 Base-TX PCI-X Adapter PCI-X Full-height Short A, L 5767 2-Port 10/100/1000 Base-TX Ethernet PCI Express Adapter PCIe Full-height Short A, i, L 5768 2-Port Gigabit Ethernet-SX PCI Express Adapter PCIe Full-height Short A, i, L 5769 10 Gigabit Ethernet-SR PCI Express Adapter PCIe Full-height Short A, i, L 5772 10 Gigabit Ethernet-LR PCI Express Adapter PCIe Full-height Short A, L
  • 71. Chapter 2. Architecture and technical overview 57 2.10.2 Graphics accelerators Table 2-14 lists the available graphics accelerators. They can be configured to operate in either 8-bit or 24-bit color modes. These adapters support both analog and digital monitors, and are not hot pluggable. Table 2-14 Available graphics accelerators 2.10.3 SCSI and SAS adapters To connect to external SCSI or SAS devices, the adapters listed in Table 2-15 are available. Table 2-15 Available SCSI and SAS adapters Table 2-16 shows a comparison between parallel SCSI and SAS. Table 2-16 Comparison parallel SCSI to SAS Feature code Adapter description Slot Size OS support 5269 PCIe LP POWER GXT145 Graphics Accelerator PCIe Low profile Short A, L 5748 POWER GXT145 PCI Express Graphics Accelerator PCIe Full-height Short A, L Feature code Adapter description Slot Size OS support 5278 PCIe LP 2-x4-port SAS Adapter 3Gb PCIe Low profile Short A, i, L 5736 PCI-X DDR Dual Channel Ultra320 SCSI Adapter PCI-X Full-height Short A, i, L 5805 PCIe 380MB Cache Dual - x4 3Gb SAS RAID Adapter PCIe Full-height Short A, i, L 5900a a. Supported, but is no longer orderable. PCI-X DDR Dual -x4 SAS Adapter PCI-X Full-height Short A, L 5901 PCIe Dual-x4 SAS Adapter PCIe Full-height Short A, i, L 5908 PCI-X DDR 1.5GB Cache SAS RAID Adapter (BSC) PCI-X Full-height Short A, i, L 5912 PCI-X DDR Dual - x4 SAS Adapter PCI-X Full-height Short A, i, L Feature Parallel SCSI SAS Architecture Parallel, all devices connected to shared bus Serial, point-to-point, discrete signal paths Performance 320 MB/s (Ultra320 SCSI), performance degrades as devices added to shared bus 3 Gb/s, roadmap to 12 Gb/s, performance maintained as more devices added Scalability 15 drives Over 16,000 drives
  • 72. 58 IBM Power 720 and 740: Technical Overview and Introduction 2.10.4 PCIe RAID & SSD SAS Adapter A new SSD option for selected POWER7 processor-based servers offers a significant price/performance improvement for many client SSD configurations. The new SSD option is packaged somewhat differently from the currently available Power Systems SSD. The new PCIe RAID & SSD SAS Adapter has up to four 177 GB SSD modules plugged directly onto the adapter, thus saving the need for the SAS bays and cabling associated with the current SSD offering. Depending on the configurations being compared to the current 69 GB SAS-bay-based SSD offering, the new PCIe-based SSD offering can save up to 70% of the list price, assuming equivalent GB, and up to 65% smaller footprint, assuming equivalent GB. Figure 2-10 shows the double-wide adapter and SSD modules. Figure 2-10 The PCIe RAID & SSD SAS Adapter and 177 GB SSD modules Table 2-17 Available PCIe RAID & SSD SAS adapters Compatibility Incompatible with all other drive interfaces Compatible with Serial ATA (SATA) Max. Cable Length 12 meters total (must sum lengths of all cables used on bus) 8 meters per discrete connection, total domain cabling hundreds of meters Cable From Factor Multitude of conductors adds bulk, cost Compact connectors and cabling save space, cost Hot Pluggability Yes Yes Device Identification Manually set, user must ensure no ID number conflicts on bus Worldwide unique ID set at time of manufacture Termination Manually set, user must ensure proper installation and functionality of terminators Discrete signal paths enable device to include termination by default Feature Parallel SCSI SAS Feature code Adapter description Slot Size OS support 2053a PCIe LP RAID & SSD SAS Adapter 3 Gb PCIe Low profile Double wide, short A, i, L 2054 PCIe RAID & SSD SAS 3 Gb PCIe Double wide, short A, i, L
  • 73. Chapter 2. Architecture and technical overview 59 a.Only supported in the Rack-mount configuration. VIOS attachment requires, Version 2.2 or later b.Only supported in a #5802/5877 PCIe I/O drawer. Not supported in the Power 720 740 CEC (Central electronic Complex). VIOS attachment requires, Version 2.2 or later The 177 GB SSD Module with Enterprise Multi-level Cell (eMLC) uses a new enterprise-class MLC flash technology, which provides enhanced durability, capacity and performance. One, two, or four modules can be plugged onto a PCIe RAID & SSD SAS adapter providing up to 708 GB of SSD capacity on one PCIe adapter. Because the SSD modules are mounted on the adapter, in order to service either the adapter or one of the modules, the entire adapter must be removed. from the system. Although the adapter can be hot plugged when installed in a #5802 or #5877 I/O drawer, removing the adapter also removes all SSD modules. So, to be able to hot plug the adapter and maintain data availability, two adapters must be installed and the data mirrored across the adapters. Under AIX and Linux, the 177 GB modules can be reformatted as JBOD disks, providing 200 GB of available disk space. This removes RAID error correcting information, so it is best to mirror the data using operating system tools in order to prevent data loss in case of failure. 2.10.5 iSCSI iSCSI adapters in Power Systems provide the advantage of increased bandwidth through the hardware support of the iSCSI protocol. The 1 Gigabit iSCSI TOE (TCP/IP Offload Engine) PCI-X adapters support hardware encapsulation of SCSI commands and data into TCP, and transports them over the Ethernet using IP packets. The adapter operates as an iSCSI TOE. This offload function eliminates host protocol processing and reduces CPU interrupts. The adapter uses a small form factor LC type fiber optic connector or a copper RJ45 connector. Table 2-18 lists the orderable iSCSI adapters. Table 2-18 Available iSCSI adapters 2.10.6 Fibre Channel adapters The systems support direct or SAN connection to devices using Fibre Channel adapters. Table 2-19 provides a summary of the available Fibre Channel adapters. All of these adapters except #5735 have LC connectors. If you are attaching a device or switch with an SC type fibre connector, an LC-SC 50 Micron Fiber Converter Cable (#2456) or an LC-SC 62.5 Micron Fiber Converter Cable (#2459) is required. 2055b PCIe RAID & SSD SAS Adapter 3 Gb w/ Blind Swap Cassette PCIe Full-Height inside a Blind Swap Cassette (BSC) Double wide, short A, i, L Note: For tower configurations, it is possible to place a PCIe-based SSD (#2055) in a #5802/5877 PCIe I/O drawer. Feature code Adapter description Slot Size OS support Feature code Adapter description Slot Size OS support #5713 1 Gigabit iSCSI TOE PCI-X on Copper Media Adapter PCI-X Full-height Short A, i, L
  • 74. 60 IBM Power 720 and 740: Technical Overview and Introduction Table 2-19 Available Fibre Channel adapters 2.10.7 Fibre Channel over Ethernet Fibre Channel over Ethernet (FCoE) allows for the convergence of Fibre Channel and Ethernet traffic onto a single adapter and converged fabric. Figure 2-11 shows a comparison between existing FC and network connections and FCoE connections. Figure 2-11 Comparison between existing FC and network connection and FCoE connection Table 2-20 lists the available Fibre Channel over Ethernet Adapters. They are high performance, Converged Network Adapters (CNA) using SR optics. Each port can provide Network Interface Card (NIC) traffic and Fibre Channel functions simultaneously. Feature code Adapter description Slot Size OS support #5273 PCIe LP 8Gb 2-Port Fibre Channel Adapter PCIe Low profile Short A, i, L #5276 PCIe LP 4Gb 2-Port Fibre Channel Adapter PCIe Low profile Short A, i, L #5735 8 Gigabit PCI Express Dual Port Fibre Channel Adapter PCIe Full-height Short A, i, L #5749 4 Gbps Fibre Channel (2-Port) PCI-X Full-height Short i #5759 4 Gb Dual-Port Fibre Channel PCI-X 2.0 DDR Adapter PCI-X Full-height Short A, L #5774 4 Gigabit PCI Express Dual Port Fibre Channel Adapter PCIe Full-height Short A, i, L Note: NPIV is supported through the Virtual I/O server with adapters #5273 and #5735. Ethernet and Fibre Channel Cables Ethernet Cable Fibre Channel Cable FC Switch Ethernet Switch CEC or I/O Drawer Ethernet CEC or I/O Drawer FC Rack Fibre Channel (FC) Device or FC Switch Ethernet Cables Ethernet Cable Fibre Channel Cable FCoE Switch CEC or I/O Drawer Rack Fibre Channel (FC) Device or FC Switch FCoE Ethernet Device/ Switch Ethernet Device/ Switch or FCoE Device/Switch
  • 75. Chapter 2. Architecture and technical overview 61 Table 2-20 Available FCoE Adapters. 2.10.8 InfiniBand Host Channel adapter The InfiniBand Architecture (IBA) is an industry-standard architecture for server I/O and inter-server communication. It was developed by the InfiniBand Trade Association (IBTA) to provide the levels of reliability, availability, performance, and scalability necessary for present and future server systems with levels significantly better than can be achieved using bus-oriented I/O structures. InfiniBand (IB) is an open set of interconnect standards and specifications. The main IB specification has been published by the InfiniBand Trade Association and is available at: http://www.infinibandta.org/ InfiniBand is based on a switched fabric architecture of serial point-to-point links, where these IB links can be connected to either host channel adapters (HCAs), used primarily in servers, or target channel adapters (TCAs), used primarily in storage subsystems. The InfiniBand physical connection consists of multiple byte lanes. Each individual byte lane is a four wire, 2.5, 5.0, or 10.0 Gbps bi-directional connection. Combinations of link width and byte lane speed allow for overall link speeds from 2.5 Gbps to 120 Gbps. The architecture defines a layered hardware protocol as well as a software layer to manage initialization and the communication between devices. Each link can support multiple transport services for reliability and multiple prioritized virtual communication channels. For more information about Infiniband, read HPC Clusters Using InfiniBand on IBM Power Systems Servers, SG24-7767. IBM offers the GX++ 12X DDR Adapter (#5615) that plugs into the system backplane (GX++ slot). One GX++ slot is available on the Power 720. Two GX++ slots are available on the Power 740. This adapter allows the attachment of up to four I/O Drawers in a single loop designed for the 12X Channel. By attaching a 12X to 4X converter cable (#1828, #1841or #1842) an IB switch can be attached. AIX, IBM i, and Linux operating systems are supported. A new PCIe2 LP 2-Port 4X Infiniband quad data rates (QDR ) Adapter 40 Gb (#5283) is available. The PCIe Gen2 low-profile adapter provides two high-speed 4X InfiniBand connections for IP over Infiniband (IB) usage in the Power 720 and Power 740. On the Power 720 and Power 740, this adapter is supported in PCIe Gen2 slots, which are provided in the PCIe Gen2 Riser Card (#5685). At time of writing , there are no other PCIe Gen2 slots available on the Power 710, 720, 730, 740, 750, 755, 770, 780, or 795. Where Gen2 PCIe slots are not available, continue to use the 12X DDR adapter in a GX slot plus a 12X to 4X cable for four InfiniBand connections (#1828, #1841 or #1842). Five QDR IB cables are provided for attachment to the QDR adapter and its QSFP(Quad Small Form-Factor Pluggable) connectors. Copper cables provide 1-, 3-, and 5-meter lengths (#3287, #3288, and 3289) Feature code Adapter description Slot Size OS support 5270 PCIe LP 10Gb FCoE 2-port Adapter PCIe Low profile Short A, L 5708 10Gb FCoE PCIe Dual Port Adapter PCIe Full-height Short A, L
  • 76. 62 IBM Power 720 and 740: Technical Overview and Introduction optical cables provide 10- and 30-meter lengths (#3290, #3293). These are QSFP/QSFP cables that then also attach to QSFP ports on the switch. The feature 5283 QDR adapter attaches to the QLogic QDR switches. These switches can ordered from IBM using the following machine types and models: 7874-036, is a QLogic 12200 36-port, 40 Gbps InfiniBand Switch that cost-effectively links workgroup resources into a cluster. 7874-072, is a QLogic 12800-040 72-port, 40 Gbps InfiniBand switch which links resources using a scalable, low-latency fabric, supporting up to four 18-port QDR Leaf Modules. 7874-324; it is a QLogic 12800-180 324-port 40 Gbps InfiniBand switch designed to maintain larger clusters, supporting up to eighteen 18-port QDR Leaf Modules. Drivers to allow direct attachment to another feature 5283 QDR Adapter are not provided by IBM. Note that the feature 5283 adapter has two 40 Gb ports and a PCIe Gen2 slot has the bandwidth to support one port. So the benefit of two ports will be for additional attachment redundancy, not for additional performance. Table 2-21 lists the available Infiniband adapters. Table 2-21 Available Infiniband adapters 2.10.9 Asynchronous adapter Asynchronous PCI adapters provide connection of asynchronous EIA-232 or RS-422 devices. If you have a cluster configuration or high-availability configuration and plan to connect the IBM Power Systems using a serial connection, you can use the features listed in Table 2-22. Table 2-22 Available asynchronous adapters 2.11 Internal storage The Power 720 and Power 740 servers use an integrated SAS/SATA connected to a 66 MHz PCI-X bus on the P5-IOC2 chip (see Figure 2-12 on page 63). The SAS/SATA controller used in the server’s enclosure has two sets of 4 SAS/SATA channels. Each channel can support Feature code Adapter description Slot Size OS support 5283 PCIe2 LP 2-Port 4X IB QDR Adapter 40Gb PCIe Low profile Short A, L 5615 GX++ Dual-port 12x Channel Attach GX++ - A, i, L Feature code Adapter description Slot Size OS support 5277 PCIe LP 4-Port Async EIA-232 Adapter PCIe Low profile Short A, L 5785 4 Port Async EIA-232 PCIe Adapter PCIe Full-height Short A, L
  • 77. Chapter 2. Architecture and technical overview 63 either SAS or SATA operation. The SAS controller is connected to a DASD backplane and supports, depending on the following two backplane options: The first (#5618) provides a storage backplane which supports six SFF (Small Form Factor) HDDs or SSDs and connections for a slimline SATA DVD and a half high tape for either a tape drive or USB removable disk drive. SFF drives are supported using JBOD or RAID-0. Split backplane (3x3) and RAID-10 support requires additional feature (#5631), but no PCIe SAS adapter is required. The second (#5630) is a higher-function backplane that supports up to eight SFF SAS HDDs/SSDs, a SATA DVD, a half-high tape drive for either a tape drive or USB removable disk, Dual 175 MB Write Cache RAID, and one external SAS port. The #5630 supports RAID 5 and RAID 6 and there is no split backplane available for this feature. Figure 2-12 details the internal topology overview for the #5618 backplane. Figure 2-12 Internal topology overview for #5618 DASD Backplane Note: The feature #5618 is not supported with IBM i. Note: This feature (#5630) is required by IBM i to natively use the internal storage (HDDs/SSDs and media) and the system SAS port. Hard disk 2 Hard disk 3 Hard disk 1 Hard disk 4 Hard disk 5 Hard disk 6 SAS Controller DASD and media backplane DVD PCI-X 64b 66MHz P5-IOC2 GX+ Pass thru PCIX PHB2 PCIX PHB0 PCIX PHB3 IVE IVE PCIe x8 PHB0 PCIe x8 PHB1 PCIe x8 PHB2 PCIe x8 PHB3 SAS Controller Tape Drive
  • 78. 64 IBM Power 720 and 740: Technical Overview and Introduction Figure 2-13 shows the internal topology overview for the #5630 backplane: Figure 2-13 #5630 DASD Backplane - Internal topology overview 2.11.1 RAID support There are multiple protection options for HDD/SSD drives in the SAS SFF bays in the Power 720 and 740 system unit or drives in 12X attached I/O drawers or drives in disk-only I/O drawers. Although protecting drives is always the best idea, AIX/Linux users can choose to leave a few or all drives unprotected at their own risk, and IBM supports these configurations. IBM i configuration rules differ in this regard, and IBM supports IBM i partition configurations only when HDD/SSD drives are protected. Drive protection HDD/SSD drive protection can be provided by AIX, IBM i, and Linux software or by the HDD/SSD hardware controllers. Mirroring of drives is provided by AIX, IBM i, and Linux software. In addition, AIX/Linux supports controllers providing RAID 0, 1, 5, 6, or 10. IBM i integrated storage management already provides striping so IBM i also supports controllers providing RAID 5 or 6. To further augment HDD/SSD protection, hot spare capability can be used for protected drives. Specific hot spare prerequisites apply. An integrated SAS HDD/SSD controller is provided in the Power 720 and Power 740 system units. It is optionally augmented by RAID 5 and RAID 6 capability when #5630 is added to the configuration. Without #5630, the integrated controller supports system mirroring protection for AIX, IBM i, and Linux and supports RAID 0 or 10 protection for AIX and Linux. Other disk and SSD controllers are available as PCI adapters, as well as PCI-X SCSI, PCI-X SAS, and PCIe SAS adapters. Hard disk 4 Hard disk 5 Hard disk 3 Hard disk 6 Hard disk 7 Hard disk 8 SAS Controller DASD and media backplane DVD PCI-X 64b 66MHz P5-IOC2 GX+ Pass thru PCIX PHB2 PCIX PHB0 PCIX PHB3 IVE IVE PCIe x8 PHB0 PCIe x8 PHB1 PCIe x8 PHB2 PCIe x8 PHB3 RAID Option External SAS Port Hard disk 2 Hard disk 1 Tape Drive
  • 79. Chapter 2. Architecture and technical overview 65 PCI Controllers with and without write cache are supported. RAID 5 and RAID 6 on controllers with write cache are supported with one exception. The PCIe RAID & SSD SAS adapter has no write cache but supports RAID 5 and RAID 6. AIX and Linux can use disk drives formatted with 512-byte blocks when being mirrored by the operating system. These disk drives must be reformatted to 528-byte sectors when used in RAID arrays. Although a small percent-age of the drive's capacity is lost, additional data protection such as ECC and bad block detection is gained in this reformatting. For example, a 300 GB disk drive, when reformatted, provides around 283 GB. IBM i always uses drives formatted to 528 bytes. IBM Power SSDs are formatted to 528 bytes. Power 720 and 740 support a dual write cache RAID feature which consists of an auxiliary write cache for RAID card and the optional RAID enablement. Supported RAID functions The RAID enablement feature and the auxiliary write cache are optional features. When features are configured, Power 720 and 740 support hardware RAID 0, 1, 5, 6 and 10: RAID-0 provides striping for performance, but does not offer any fault tolerance. The failure of a single drive will result in the loss of all data on the array. This increases I/O bandwidth by simultaneously accessing multiple data paths. RAID-5 uses block-level data striping with distributed parity. RAID-5 stripes both data and parity information across three or more drives. Fault tolerance is maintained by ensuring that the parity information for any given block of data is placed on a drive separate from those used to store the data itself. RAID-6 uses block-level data striping with dual distributed parity. RAID-6 is the same as RAID-5 except that it uses a second level of independently calculated and distributed parity information for additional fault tolerance. RAID-6 configuration requires N+2 drives to accommodate the additional parity data, which makes it less cost effective than RAID-5 for equivalent storage capacity. RAID-10 is also known as stripe set of mirrored arrays. It is a combination of RAID-0 and RAID-1. A RAID-0 stripe set of the data is created across a 2-disk array for performance benefits. A duplicate of the first stripe set is then mirrored on another 2-disk array for fault tolerance. 2.11.2 External SAS port and split backplane This section describes the external SAS port and split backplane features. External SAS port feature The Power 720 and 740 DASD backplane (#5630) offers an external SAS port: The SAS port connector is located next to the GX++ slot 2 on the rear bulkhead. The external SAS port can be used to connect external SAS devices (#5886 or #5887), System Storage 7214 Tape and DVD Enclosure 7214-IU2 or the Multi-media Enclosure 7316-1U2. Note: Only one SAS drawer is supported from the external SAS port. Additional SAS drawers can be supported by SAS adapters. SSDs are not supported on the SAS drawer connected to the external port.
  • 80. 66 IBM Power 720 and 740: Technical Overview and Introduction Split DASD backplane feature Power 720 and 740 DASD backplane (#5618) supports split drive bay (#5631). If #5631 is configured, then the six Small Form Factors (SFFs) are split into a pair of three drive bay groups (3x3) and RAID-10 capability is enabled. Figure 2-14 details the split backplane. Figure 2-14 Internal topology overview for #5618 DASD Backplane with Split backplane feature #5631 2.11.3 Media bays The Power 720 and 740 each offer a slim media bay to support a slim SATA DVD device. Direct dock and hot-plug of the DVD media device are supported. Also, the half-high bay is available to support an optional SAS tape drive or removable disk drive. Note: In a Power 720 and 740 with a split backplane, SSDs and HDDs can be placed in either “split” but no mixing of SSDs and HDDs within a split is allowed. IBM i does not support split backplane. Hard disk 2 Hard disk 3 Hard disk 1 Hard disk 4 Hard disk 5 Hard disk 6 SAS Controller DASD and media backplane DVD PCI-X 64b 66MHz P5-IOC2 GX+ Pass thru PCIX PHB2 PCIX PHB0 PCIX PHB3 IVE IVE PCIe x8 PHB0 PCIe x8 PHB1 PCIe x8 PHB2 PCIe x8 PHB3 SAS Controller Tape Drive
  • 81. Chapter 2. Architecture and technical overview 67 2.12 External I/O subsystems This section describes the external 12X I/O subsystems that can be attached to the Power 720 and Power 740, listed as follows: PCI-DDR 12X Expansion Drawer (#5796) 12X I/O Drawer PCIe, SFF disk (#5802) 12X I/O Drawer PCIe, No Disk (#5877) 12X I/O Drawer PCIe with SFF Disks (#5802) Table 2-23 provides an overview of the capabilities of the supported I/O drawers: Table 2-23 I/O drawer capabilities Each processor card feeds one GX++ Adapter slot. On the Power 720, there can be one GX++ slot available, and on the Power 740, there can be one or two, depending on whether one or two processor modules are installed. 2.12.1 PCI-DDR 12X Expansion Drawer The PCI-DDR 12X Expansion Drawer (#5796) is a 4U (EIA units) drawer and mounts in a 19-inch rack. Feature #5796 is 224 mm (8.8 in.) wide and takes up half the width of the 4U (EIA units) rack space. The 4U enclosure can hold up to two #5796 drawers mounted side-by-side in the enclosure. The drawer is 800 mm (31.5 in.) deep and can weigh up to 20 kg (44 lb). The PCI-DDR 12X Expansion Drawer has six 64-bit, 3.3 V, PCI-X DDR slots, running at 266 MHz and that use blind-swap cassettes and support hot-plugging of adapter cards. The drawer includes redundant hot-plug power and cooling. Two interface adapters are available for use in the #5796 drawer: Dual-Port 12X Channel Attach Adapter Long Run (#6457) or Dual-Port 12X Channel Attach Adapter Short Run (#6446). The adapter selection is based on how close the host system or the next I/O drawer in the loop is physically located. Feature #5796 attaches to a host system CEC enclosure with a 12X adapter in a GX++ slot through SDR or DDR cables (or both SDR and DDR cables). A maximum of four #5796 drawers can be placed on the same 12X loop. Mixing #5802/5877 and #5796 on the same loop is not supported. A minimum configuration of two 12X cables (either SDR or DDR), two ac power cables, and two SPCN cables, is required to ensure proper redundancy. Feature code DASD PCI slots Requirements for a 720/740 #5796 None 6 x PCI-X GX++ adapter card #5615 and interface attach 6446/6457 #5802 18 x SFF disk drive bays 10 x PCIe GX++ adapter card #5615 #5877 None 10 x PCIe GX++ adapter card #5615 #5887 24 x SAS disk drive bays None SAS PCI-X or PCIe adapter #5886 12 x SAS disk drive bays None SAS PCI-X or PCIe adapter Note: The attachment of external I/O drawers is not supported on the 4-core Power 720.
  • 82. 68 IBM Power 720 and 740: Technical Overview and Introduction Figure 2-15 shows the back view of the expansion unit. Figure 2-15 PCI-X DDR 12X Expansion Drawer rear side 2.12.2 12X I/O Drawer PCIe The 12X I/O Drawer PCIe (#5802) is a 19-inch I/O and storage drawer. It provides a 4U-tall (EIA units) drawer containing ten PCIe based I/O adapter slots and eighteen SAS hot-swap Small Form Factor disk bays, which can be used for either disk drives or SSD. The adapter slots use blind-swap cassettes and support hot-plugging of adapter cards. A maximum of two #5802 drawers can be placed on the same 12X loop. Feature #5877 is the same as #5802 except it does not support any disk bays. Feature #5877 can be on the same loop as #5802. Feature #5877 cannot be upgraded to #5802. The physical dimensions of the drawer measure 444.5 mm (17.5 in.) wide by 177.8 mm (7.0 in.) high by 711.2 mm (28.0 in.) deep for use in a 19-inch rack. A minimum configuration of two 12X DDR cables, two ac power cables, and two SPCN cables is required to ensure proper redundancy. The drawer attaches to the host CEC enclosure with a 12X adapter in a GX++ slot through 12X DDR cables that are available in various cable lengths: 0.6 (#1861), 1.5 (#1862), 3.0 (#1865), or 8 meters (#1864). The 12X SDR cables are not supported. P1-C8-T3 P1-C1 P1-C2 P1-C3 P1-C4 P1-C5 E1 P1-C6 E2 12X Port 1 (P1-C7-T2) SPCN 0 (P1-C8-T1) SPCN 1 (P1-C8-T2) 12X Port 0 (P1-C7-T1) C 1 C 2 C 3 C 4 C 5 C 6
  • 83. Chapter 2. Architecture and technical overview 69 Figure 2-16 shows the front view of the 12X I/O Drawer PCIe (#5802). Figure 2-16 Front view of the 12X I/O Drawer PCIe Figure 2-17 shows the rear view of the 12X I/O Drawer PCIe (#5802). Figure 2-17 Rear view of the 12X I/O Drawer PCIe 2.12.3 Dividing SFF drive bays in a 12X I/O drawer PCIe Disk drive bays in a 12X I/O drawer PCIe can be configured as a set of one, two, or four, allowing for partitioning of disk bays. Disk bay partitioning configuration can be done by physical mode switch on the I/O drawer. Disk drives Service card Port cards Power cables 10 PCI-e cards X2 SAS connectors 12X connectors Mode switch SPCN connectors Note: Mode change using the physical mode switch requires power-off/on of the drawer.
  • 84. 70 IBM Power 720 and 740: Technical Overview and Introduction Figure 2-17 on page 69 indicates the Mode Switch in the rear view of the #5802 I/O Drawer. Each disk bay set can be attached to its own controller or adapter. #5802 PCIe 12X I/O Drawer has four SAS connections to drive bays. It connects to PCIe SAS adapters or controllers on the host system. Figure 2-18 shows the configuration rule of disk bay partitioning in the #5802 PCIe 12X I/O Drawer. There is no specific feature code for mode switch setting. Figure 2-18 Disk Bay Partitioning in #5802 PCIe 12X I/O drawer The SAS ports, as associated with the mode selector switch map to the disk bays, have the mappings shown in Table 2-24. Table 2-24 SAS connection mappings Note: The IBM System Planing Tool supports disk bay partitioning. Also, the IBM configuration tool accepts this configuration from IBM System Planing Tool and passes it through IBM manufacturing using the Customer Specified Placement (CSP) option. Location code Mappings Number of bays P4-T1 P3-D1 to P3-D5 5 bays P4-T2 P3-D6 to P3-D9 4 bays P4-T3 P3-D10 to P3-D14 5 bays P4-T3 P3-D15 to P3-D18 4 bays
  • 85. Chapter 2. Architecture and technical overview 71 Location codes for #5802 I/O drawer The location codes for the front and rear views of the #5802 I/O drawer are provided in Figure 2-19 and Figure 2-20. Figure 2-19 5802 I/O drawer from view location codes Figure 2-20 5802 I/O drawer rear view location codes
  • 86. 72 IBM Power 720 and 740: Technical Overview and Introduction Configuring the #5802 disk drive subsystem The #5802 SAS disk drive enclosure can hold up 18 disk drives. The disks in this enclosure can be organized in various configurations depending on the operating system used, the type of SAS adapter card, and the position of the mode switch. Each disk bay set can be attached to its own controller or adapter. Feature #5802 PCIe 12X I/O Drawer has four SAS connections to drive bays. It connects to PCIe SAS adapters or controllers on the host systems. For detailed information about how to configure, see the IBM Power Systems Hardware Information Center at: http://publib.boulder.ibm.com/infocenter/powersys/v3r1m5/index.jsp 2.12.4 12X I/O drawer PCIe and PCI-DDR 12X Expansion Drawer 12X cabling I/O Drawers are connected to the adapters in the CEC enclosure with data transfer cables: 12X DDR cables for the #5802 and #5877 I/O drawers, and 12X SDR and/or DDR cables for the #5796 I/O drawers. The first 12X I/O Drawer that is attached in any I/O drawer loop requires two data transfer cables. Each additional drawer, up to the maximum allowed in the loop, requires one additional data transfer cable. Note the following information: A 12X I/O loop starts at a CEC bus adapter port 0 and attaches to port 0 of an I/O drawer. The I/O drawer attaches from port 1 of the current unit to port 0 of the next I/O drawer. Port 1 of the last I/O drawer on the 12X I/O loop connects to port 1 of the same CEC bus adapter to complete the loop. Figure 2-21 shows typical 12X I/O loop port connections. Figure 2-21 Typical 12X I/O loop port connections I/O I/O 1 0 I/O 1 0 I/O 10 I/O 10 C 0 1
  • 87. Chapter 2. Architecture and technical overview 73 Table 2-25 shows various 12X cables to satisfy the various length requirements. Table 2-25 12X connection cables General rules for 12X IO Drawer configuration If you have two processor cards, spread the I/O drawers across two busses for better performance. Figure 2-22 lists the configuration to attach 12X IO Drawers to a Power 720. Figure 2-22 12X IO Drawer configuration for a Power 720 with one GX++ slot Feature code Description 1861 0.6 Meter 12X DDR Cable 1862 1.5 Meter 12X DDR Cable 1865 3.0 Meter 12X DDR Cable 1864 8.0 Meter 12X DDR Cable PCIe 720 + + One I/O-Drawer PCIe 720 + + Two I/O-Drawers PCIe PCI-X 720 + + One I/O-Drawer PCI-X 720 + + Four I/O-Drawers PCI-X PCI-X PCI-X
  • 88. 74 IBM Power 720 and 740: Technical Overview and Introduction The configuration rules are the same for the Power 740. However, because the Power 740 can have up to two GX++ slots, you have various options available to attach 12X IO drawers. Figure 2-23 shows four of them, but there are more options available. Figure 2-23 12X IO Drawer configuration for a Power 740 with one GX++ slot Supported 12X cable length for PCI-DDR 12X Expansion Drawer Each #5796 drawer requires one Dual Port PCI DDR 12X Channel Adapter, either Short Run (#6446) or Long Run (#6457). The choice of adapters is dependent on the distance to the next 12X Channel connection in the loop, either to another I/O drawer or the system unit. Table 2-26 identifies the supported cable lengths for each 12X channel adapter. I/O drawers containing the Short Range adapter can be mixed in a single loop with I/O drawers containing the Long Range adapter. In Table 2-26, a “Yes” indicates that the 12X cable identified in that column can be used to connect the drawer configuration identified to the left. A “No” means it cannot be used. Table 2-26 Supported 12X cable length Connection type 12X cable options 0.6 M 1.5 M 3.0 M 8.0 M #5796 to #5796 with #6446 in both drawers Yes Yes No No #5796 with #6446 adapter to #5796 with 6457 adapter Yes Yes Yes No #5796 to #5796 with 6#457 adapter in both drawers Yes Yes Yes Yes #5796 with #6446 adapter to system unit No Yes Yes No #5796 with #6457 adapter to system unit No Yes Yes No PCIe 740 + + Three I/O-Drawers PCIe Six I/O-Drawers PCI-X PCI-X PCI-X PCI-X PCIe PCIe 740 + + + + PCI-X+ + PCIe 740 + + Four I/O-Drawers PCIe PCI-X PCI-X + + Two I/O-Drawers PCIe740 + + PCIe + +
  • 89. Chapter 2. Architecture and technical overview 75 2.12.5 12X I/O Drawer PCIe and PCI-DDR 12X Expansion Drawer SPCN cabling The System Power Control Network (SPCN) is used to control and monitor the status of power and cooling within the I/O drawer. SPCN cables connect all ac powered expansion units as shown in the following example diagram, Figure 2-24. 1. Start at SPCN 0 (T1) of the CEC unit to J15 (T1) of the first expansion unit. 2. Cable all units from J16 (T2)of the previous unit to J15 (T1) of the next unit. 3. To complete the cabling loop, from J16 (T2) of the final expansion unit, connect to the CEC, SPCN 1 (T2). 4. Ensure that a complete loop exists from the CEC, through all attached expansions and back to the CEC drawer. Figure 2-24 SPCN cabling examples Table 2-27 shows SPCN cables to satisfy various length requirements: Table 2-27 SPCN cables 2.13 External disk subsystems This section describes The following external disk subsystems that can be attached to the Power 720 and Power 740, listed as follows: EXP 12S SAS Expansion Drawer (#5886 - Supported, but is no longer orderable). EXP 24S SFF Gen2-bay Drawer for high-density storage(#5887) TotalStorage EXP24 Disk Drawer (#5786) and Tower (#5787) J15 J16 J15 J16 J15 J16 System Unit 1 0 Feature code Description 6006 SPCN cable drawer-to-drawer, 2 m 6008a a. Supported, but no longer orderable SPCN cable rack-to-rack, 6 m 6007 SPCN cable rack-to-rack, 15 m 6029a SPCN cable rack-to-rack, 30 m
  • 90. 76 IBM Power 720 and 740: Technical Overview and Introduction IBM 7031 TotalStorage EXP24 Ultra320 SCSI Expandable Storage Disk Enclosure (no longer orderable) IBM System Storage The next sections describe the EXP 12S Expansion Drawer, the 12X I/O Drawer PCIe with SFF Disks drawer, and IBM System Storage in more detail. 2.13.1 EXP 12S SAS Expansion Drawer The EXP 12S (#5886) is an expansion drawer with twelve 3.5-inch form factor SAS bays. #5886 supports up to 12 hot-swap SAS Hard Disk Drives (HDD) or up to 8 hot-swap Solid State Drives (SSD). The EXP 12S includes redundant ac power supplies and two power cords. Though the drawer is one set of 12 drives which is run by one SAS controller or one pair of SAS controllers, it has two SAS attachment ports and two Service Managers for redundancy. The EXP 12S takes up a 2 EIA space in a 19-inch rack. The SAS controller can be a SAS PCI-X or PCIe adapter or pair of adapters. At the time of writing, a single disk-only EXP 12S SAS Expansion Drawer (#5886) is supported from the external SAS port of a Power 720 and Power 740 server. Additional EXP 12S Drawers can be supported using PCI-X or PCIe SAS adapters. A maximum of 28 EXP 12S Drawers are supported on a Power 720 and Power 740 server. The drawer can either be attached using the #5630 storage backplane, providing an external SAS port, or using one of the following adapters: PCIe LP 2-x4-port SAS 3GB adapter (#5278) PCIe 380 MB Cache Dual -x4 3 GB SAS RAID adapter (#5805) PCI-X DDR Dual -x4 SAS adapter (#5900) PCIe Dual -x4 SAS adapter (#5901) PCIe 380 MB Cache Dual -x4 3 GB SAS RAID adapter (#5903) PCI-X DDR 1.5 GB Cache SAS RAID adapter (#5904) PCI-X DDR Dual -x4 SAS adapter (#5912) With proper cabling and configuration, multiple wide ports are used to provide redundant paths to each dual port SAS disk. The adapter manages SAS path redundancy and path switching in case a SAS drive failure occurs. The SAS Y cables attach to an EXP 12S Disk Drawer. Use SAS cable (YI) system to SAS enclosure, single controller/dual path 1.5M (#3686 - supported but not longer orderable) or SAS cable (YI) system to SAS enclosure, single controller/dual path 3M (#3687) to attach SFF SAS drives in an EXP12S Drawer. Figure 2-25 on page 77 illustrates connecting a system external SAS port to a disk expansion drawer Note: The 4-core Power 720 server does not support the attachment of an EXP12S Drawer. Note: If you use a PCI-X SAS adapter within the Power 720 and 740, a PCI-X DDR 12X Expansion Drawer (#5796) or a 7314-G30 drawer is required.
  • 91. Chapter 2. Architecture and technical overview 77 Figure 2-25 External SAS Cabling Use SAS cable (YO) system to SAS enclosure, single controller/dual path 1.5M (#3450) or SAS cable (YO) system to SAS enclosure, single controller/dual path 3M (#3451) to attach SFF SAS drives in an EXP12S Drawer. In the EXP 12S Drawer, a high availability I/O configuration can be created using a pair of #5278 adapters and SAS X cables to protect against the failure of a SAS adapter. Various disk options are available to be installed in the EXP 12S drawer. Table 2-28 on page 77 shows the available disk drive feature codes. Table 2-28 Disk options for the EXP 12S drawer Feature code Description OS support #3586 69 GB 3.5" SAS Solid State Drive AIX, Linux #3587 69 GB 3.5” SAS Solid State Drive IBM i #3646 73.4 GB 15K RPM SAS Disk Drive AIX. Linux #3647 146.8 GB 15K RPM SAS Disk Drive AIX, Linux #3648 300 GB 15K RPM SAS Disk Drive AIX, Linux #3649 450 GB 15K RPM SAS Disk Drive AIX, Linux #3658 428.4 GB 15K RPM SAS Disk Drive IBM i #3676 69.7 GB 15K RPM SAS Disk Drive IBM i #3677 139.5 GB 15K RPM SAS Disk Drive IBM i #3678 283.7 GB 15K RPM SAS Disk Drive IBM i
  • 92. 78 IBM Power 720 and 740: Technical Overview and Introduction A second EXP12S drawer can be attached to another drawer using two SAS EE cables, providing 24 SAS bays instead of 12 bays for the same SAS controller port. This is called cascading. In this configuration, all 24 SAS bays are controlled by a single controller or a single pair of controllers. The EXP12S Drawer can also be directly attached to the SAS port on the rear of the Power 720 and Power 740, providing a very low cost disk storage solution. The rear SAS port is provided by the Storage Backplane - 8 SFF Bays/175MB RAID/Dual IOA (#5630). A second unit cannot be cascaded to an EXP12S Drawer attached in this way. For detailed information about the SAS cabling, see the Serial-attached SCSI cable planning documentation at: http://publib.boulder.ibm.com/infocenter/powersys/v3r1m5/index.jsp?topic=/p7had/p7 hadsascabling.htm 2.13.2 EXP 24S SAS Expansion Drawer The EXP 24S (#5887) SFF Gen2-bay Drawer is an expansion drawer with twenty-four 2.5- inch small form factor (SFF) SAS bays. It supports up to 24 hot-swap SFF SAS Hard Disk drives (HDD) on POWER6 or POWER7 servers in 2U of 19-inch rack space. The SFF bays of the EXP 24S are different from the SFF bays of the POWER7 system units or 12X PCIe I/O Drawers (#5802, #5803). The EXP 24S uses Gen-2 or SFF-2 SAS drives that physically do not fit in the Gen-1 or SFF-1 bays of the POWER7 system unit or 12X PCIe I/O Drawers or viceversa. The EXP 24S SAS ports are attached to SAS controllers which can be a SAS PCI-X or PCIe adapter or pair of adapters. The EXP24S can also be attached to an imbedded SAS controller in a server with an imbedded SAS port. Attachment between the SAS controller and the EXP24S SAS ports is via the appropriate SAS Y or X cables. The drawer can either be attached using the #5268 storage backplane, providing an external SAS port, or using a LP 2-x4-port SAS adapter 3 Gb (#5278). Note: A EXP 12S Drawer containing SSD drives cannot be attached to the CEC external SAS port on the Power 720 and Power 740 or through a PCIe LP 2-x4 port SAS adapter 3Gb (#5278). If this configuration is required, use a high-profile PCIe SAS adapter or a PCI-X SAS adapter. Note: If the internal disk bay of the Power 720 or Power 740 contains any SSD drives, an EXP 12S Drawer cannot be attached to the external SAS port on the Power 720 or Power 740 (this applies even if the I/O drawer only contains SAS disk drives). Note: SSD not currently supported Note: A single #5887 drawer can be cabled to the CEC external SAS port when a #5268 DASD backplane is part of the system. A 3Gb/s YI cable (#3686/#3687) is used to connect a #5887 to the CEC external SAS port. A single #5887 will not be allowed to attach to the CEC external SAS port when a #8350 processor (4-core) is ordered/installed on a single socket Power 710 system.
  • 93. Chapter 2. Architecture and technical overview 79 The EXP 24S can be ordered in one of 3 possible manufacturing-configured MODE settings (not customer set-up). 1, 2 or 4 sets of disk bays With IBM AIX/Linux/VIOS, the EXP 24S can be ordered with four sets of 6 bays (mode4), two sets of 12 bays (mode 2) or one set of 24 bays (mode 1). With IBM i the EXP24S can be ordered as one set of 24 bays (mode 1). There are six SAS connectors on the rear of the EXP 24S to which SAS adapters/ controllers are attached. They are labeled T1, T2, and T3, and there are two T1, two T2, and two T3, details on Figure 2-26. In mode 1, two or four of the six ports are used. Two T2 are used for a single SAS adapter, and two T2 and two T3 are used with a paired set of two adapters or dual adapters configuration In mode 2 or mode 4, four ports will be used, two T2 and two T3 in order to access allSAS bays. Figure 2-26 #5887 rear connectors An EXP 24S in mode 4 can be attached to two or four SAS controllers and provide a great deal of configuration flexibility. An EXP24S in mode 2 has similar flexibility. Up to 24 HDDs can be supported with any of the supported SAS adapters/controllers. EXP24S no-charge specify codes should be included with EXP24S orders to indicate IBM Manufacturing the mode to which the drawer should be set and the adapter/controller/cable configuration which will be used. Table 2-29 lists the no-charge specify codes, the physical adapters/controllers/cables with their own chargeable feature numbers. Table 2-29 EXP 24S Cabling Note: #5887 Modes are set by IBM Manufacturing. No option to reset after IBM ships is announced. If ordering multiple EXP24S avoid mixing modes within that order. There is no externally visible indicator as to the drawer's mode. SSD are not currently supported in EXP24S . No Cascading of #5887s - Max one #5887 per SAS connector Power 720 or Power 740 can support up to 14 #5887 Feature code Mode Adapter/controller Cable to Drawer Environment #9359 1 One #5278 1 YO Cable A, L,VIOS #9360 1 Pair #5278 2 YO Cables A, L,VIOS #9361 2 Two #5278 2 YO Cables A, L,VIOS
  • 94. 80 IBM Power 720 and 740: Technical Overview and Introduction Cable to EXP 24S Drawer options: X cables for #5278 : 3 m (#3661), 6 m (#3662), 15 m (#3663) YO cables for #5278: 1.5 m (#3691), 3 m (#3692), 6 m (#3693), 15 m (#3694) YI cables for system unit SAS port (3 Gb): 1.5 m (#3686) or 3 m (#3687) For detailed information about the SAS cabling, see the serial-attached SCSI cable planning documentation at: http://publib.boulder.ibm.com/infocenter/powersys/v3r1m5/index.jsp?topic=/p7had/p7 hadsascabling.htm 2.13.3 TotalStorage EXP24 disk drawer and tower The TotalStorage EXP24 is available as a 4 EIA unit drawer and mounts in a 19-inch rack (#5786) and a tower (#5787). The front of the IBM TotalStorage EXP24 Ultra320 SCSI Expandable Storage Disk Enclosure has bays for up to 12 disk drives organized in two SCSI groups of up to six drives. The rear also has bays for up to 12 disk drives organized in two additional SCSI groups of up to six drives plus slots for the four SCSI interface cards. Each SCSI drive group can be connected by either a Single Bus Ultra320 SCSI Repeater Card (#5741) or a Dual Bus Ultra320 SCSI Repeater Card (#5742). This allows the EXP24 to be configured as four sets of six bays, two sets of 12 bays, or two sets of six bays plus one set of 12 bays. The EXP24 features #5786 and #5787 have three cooling fans and two power supplies to provide redundant power and cooling. The SCSI disk drives contained in the EXP24 are controlled by PCI-X SCSI adapters connected to the EXP24 SCSI repeater cards by SCSI cables. The PCI-X adapters are located in the Power 740 system unit or in an attached I/O drawer with PCI-X slots. The 336 system maximum is achieved with a maximum of 24 disks in a maximum of 14 TotalStorage EXP24 disk drawers (#5786) or 14 TotalStorage EXP24 disk towers (#5787). #9365 4 Four #5278 2 X Cable A, L,VIOS #9366 2 Two pair #5278 2 X Cables A, L,VIOS #9367 1 Pair #5805 2 YO Cables A,i, L,VIOS #9368 2 Two 5805 2 X Cables A, L,VIOS #9382 1 One #5904/06/08 1 YO Cable A,i, L,VIOS #9383 1 Pair #5904/06/08 2 YO Cables A,i, L,VIOS #9384 1 CEC SAS port 1 YI Cable A,i, L,VIOS Note: EXP24S Drawer rails are fixed lenght and designed to fit Power Systems provided racks of 28 inches (8xx mm) deep. EXP24S Uses 2 EIA of space in a 19-inch wide rack. Other racks may have different depths and these rails won't adjust. No adjustable depth rails are orderable at this time Feature code Mode Adapter/controller Cable to Drawer Environment
  • 95. Chapter 2. Architecture and technical overview 81 2.13.4 IBM TotalStorage EXP24 The IBM 7031 TotalStorage EXP24 Ultra320 SCSI Expandable Storage Disk Enclosure supports up to 24 Ultra320 SCSI Disk Drives arranged in four independent SCSI groups of up to six drives or in two groups of up to twelve drives. Each SCSI drive group can be connected by either a Single Bus Ultra320 SCSI Repeater Card or a Dual Bus Ultra320 SCSI Repeater Card, allowing a maximum of eight SCSI connections per TotalStorage EXP24. The IBM 7031 Model D24 (7031-D24) is an Expandable Disk Storage Enclosure that is a horizontal 4 EIA by 19-inch rack drawer for mounting in equipment racks. The IBM 7031 Model T24 (7031-T24) is an Expandable Disk Storage Enclosure that is a vertical tower for floor-standing applications. 2.13.5 IBM System Storage The IBM System Storage Disk Systems products and offerings provide compelling storage solutions with superior value for all levels of business, from entry-level up to high-end storage systems. IBM System Storage N series The IBM System Storage N series is a Network Attached Storage (NAS) solution and provides the latest technology to customers to help them improve performance, virtualization manageability, and system efficiency at a reduced total cost of ownership. For more information about the IBM System Storage N series hardware and software, see: http://www.ibm.com/systems/storage/network IBM System Storage DS3000 family The IBM System Storage DS3000 is an entry-level storage system designed to meet the availability and consolidation needs for a wide range of users. New features, including larger capacity 450 GB SAS drives, increased data protection features such as RAID 6, and more FlashCopies per volume, provide a reliable virtualization platform. For more information about the DS3000 family, see: http://www.ibm.com/systems/storage/disk/ds3000/index.html IBM System Storage DS5000 New DS5000 enhancements help reduce cost by introducing SSD drives. Also with the new EXP5060 expansion unit supporting 60 1 TB SATA drives in a 4U package, customers can see up to a 1/3 reduction in floor space over standard enclosures. With the addition of 1 Gbps Note: The EXP24S SCSI disk drawer is an earlier technology drawer compared to the later SAS EXP12S drawer. It is used to house the older SCSI disk drives that are supported, but is no longer orderable. Note: A new IBM 7031 TotalStorage EXP24 Ultra320 SCSI Expandable Storage Disk Enclosure cannot be ordered for the Power 720 and Power 740, and thus only existing 7031-D24 drawers or 7031-T24 towers can be moved to the Power 720 and 740 servers. AIX and Linux partitions are supported along with the usage of a IBM 7031 TotalStorage EXP24 Ultra320 SCSI Expandable Storage Disk Enclosure.
  • 96. 82 IBM Power 720 and 740: Technical Overview and Introduction iSCSI host attach, customers can reduce cost for their less demanding applications while continuing to provide high performance where necessary utilizing the 8 Gbps FC host ports. With the DS5000 family, you get consistent performance from a smarter design that simplifies your infrastructure, improves your TCO, and reduces your cost. For more information about the DS5000 family, see: http://www.ibm.com/systems/storage/disk/ds5000/index.html IBM Storwize V7000 Midrange Disk System IBM® Storwize® V7000 is a virtualized storage system to complement virtualized server environments that provides unmatched performance, availability, advanced functions, and highly scalable capacity never seen before in midrange disk systems. Storwize V7000 is a powerful midrange disk system that has been designed to be easy to use and enable rapid deployment without additional resources. Storwize V7000 is virtual storage that offers greater efficiency and flexibility through built-in solid state drive (SSD) optimization and thin provisioning technologies. Storwize V7000 advanced functions also enable non-disruptive migration of data from existing storage, simplifying implementation and minimizing disruption to users. Storwize V7000 also enables you to virtualize and reuse existing disk systems, supporting a greater potential return on investment (ROI). For more information about Storwize V7000, see: http://www.ibm.com/systems/storage/disk/storwize_v7000/index.html IBM XIV Storage System IBM offers a mid–sized configuration of its self-optimizing, self-healing, resilient disk solution, the IBM XIV® Storage System: storage reinvented for a new era. Now, organizations with mid-size capacity requirements can take advantage of IBM’s latest technology for their most demanding applications with as little as 27TB usable capacity and incremental upgrades. For more information about XIV, see: http://www.ibm.com/systems/storage/disk/xiv/index.html IBM System Storage DS8000 The IBM System Storage DS8000® family is designed to offer high availability, multiplatform support, and simplified management tools. With its high capacity, scalability, broad server support, and virtualization features, the DS8000 family is well suited for simplifying the storage environment by consolidating data from multiple storage systems on a single system. The high-end model DS8700 is the most advanced model in the IBM DS8000 family lineup and introduces new dual IBM POWER6-based controllers that usher in a new level of performance for the company’s flagship enterprise disk platform. The DS8700 offers twice the maximum physical storage capacity than the previous model. For more information about the DS8000 family, see: http://www.ibm.com/systems/storage/disk/ds8000/index.html 2.14 Hardware Management Console The Hardware Management Console (HMC) is a dedicated workstation that provides a graphical user interface for configuring, operating, and performing basic system tasks for the POWER7 processor-based, as well as the previous POWER5, POWER5+, POWER6 and POWER6+ processor-based systems. Either non-partitioned, partitioned, or clustered environments are supported. In addition the HMC is used to configure and manage logical partitions (LPARs). One HMC is capable of controlling multiple POWER5, POWER5+, POWER6 and POWER6+ and POWER7 processor-based systems.
  • 97. Chapter 2. Architecture and technical overview 83 At the time of writing, one HMC supports, in general, up to 1024 LPARs using HMC machine code Version 7 Release 710 or later. It can also support up to 48 Power 710, Power 720, Power 730, Power 740, Power 750, Power 755, Power 770, or Power 780. Up to 32 Power 795 servers are supported. For updates of the machine code and HMC functions and hardware prerequisites, see the following website: http://www.ibm.com/support/fixcentral 2.14.1 HMC functional overview The HMC provides three groups of tasks, as described in the following topics. Server management The first group contains all tasks related to the management of the physical servers under the control of the HMC: System password Power on/off Capacity on Demand Error management: – System indicators – Error/event collection reporting – Dump collection reporting – Call home – Customer notification – Hardware replacement (guided repair) – SNMP events Concurrent add/repair Redundant Service Processor Firmware updates Virtualization management The second group contains all tasks related to virtualization features such as the Logical Partition configuration or dynamic reconfiguration of resources: System Plans System Profiles Logical Partitions (create, activate, shutdown) Profiles Partition Mobility Dynamic LPAR operations (add/remove/move processors, memory, I/O, and so on.) Custom Groups HMC console management The last group relates to the management of the HMC itself, its maintenance, security, or configuration. Here are a few examples: Set-up wizard Note: The Integrated Virtualization Manager (IVM) is required to managed IBM Power Architecture® blades. For more information, see 2.15, “Integrated Virtualization Manager” on page 87.
  • 98. 84 IBM Power 720 and 740: Technical Overview and Introduction User management: – User IDs – Authorization levels – Customizable authorization Disconnect/reconnect Network security: – Remote operation enable/disable – User definable SSL certificates Console logging HMC redundancy Scheduled operations Back up and restore Updates, upgrades Customizable message of the day The HMC version V7R720 adds support for Power 710, Power 720, Power 730, Power 740, and Power 795 servers. The HMC provides both graphical and command line interface for all management tasks. Running HMC Version 7, a remote connection to the HMC using a web browser or SSH is possible. A command line interface is also available by using the SSH secure shell connection to the HMC. It can be used by an external management system or a partition to perform HMC operations remotely. 2.14.2 HMC connectivity to the POWER7 processor based systems POWER5, POWER5+, POWER6, POWER6+, and POWER7 processor-based servers managed by an HMC require Ethernet connectivity between the HMC and the server Service Processor. In addition, if dynamic LPAR, Live Partition Mobility or PowerVM Active Memory Sharing operations are required on the managed partitions, Ethernet connectivity is needed between these partitions and the HMC. A minimum of two Ethernet ports are needed on the HMC to provide such connectivity. The rack-mounted 7042-CR5 and 7042-CR6 HMC default configuration provides four Ethernet ports. The deskside 7042-C07 and 7042-C08 HMC standard configuration offers one Ethernet port. Preferably, order an optional PCIe adapter to provide additional Ethernet ports. For any logical partition in a server, it is possible to use a Shared Ethernet Adapter in the Virtual I/O Server or Logical Ports of the Integrated Virtual Ethernet card, for fewer connections from the HMC to partitions. Therefore, a partition does not require it’s own physical adapter to communicate to an HMC. It is a good practice to connect the HMC to the first HMC port on the server, which is labeled as HMC Port 1, although other network configurations are possible. You can attach a second HMC to HMC Port 2 of the server for redundancy. Figure 2-27 shows a simple network configuration to enable the connection from an HMC to a server in order to enable Dynamic LPAR operations. For more details about HMC and the possible network connections, see the Hardware Management Console V7 Handbook, SG24-7491.
  • 99. Chapter 2. Architecture and technical overview 85 Figure 2-27 HMC to service processor and LPARs network connection The default mechanism for allocation of the IP addresses for the service processor HMC ports is dynamic. The HMC can be configured as a DHCP server, providing the IP address at the time the managed server is powered on. In this case, the Flexible Service Processor (FSP) is allocated IP address from a set of address ranges predefined in the HMC software. These predefined ranges are identical for version 720 of the HMC code and for previous versions. If the service processor of the managed server does not receive the DHCP reply before time-out, predefined IP addresses will be setup on both ports. Static IP address allocation is also an option. You can also configure the IP address of the service processor ports with a static IP address by using the Advanced System Management Interface (ASMI) menus. Note: The service processor is used to monitor and manage the system hardware resources and devices. The service processor offers the following connections: Two Ethernet 10/100 Mbps ports are provided: Both Ethernet ports are only visible to the service processor and can be used to attach the server to an HMC or to access the Advanced System Management Interface (ASMI) options from a client web browser, using the http server integrated into the service processor internal operating system. When not configured otherwise (DHCP or from a previous ASMI setting), both Ethernet ports of the first FSP have predefined IP addresses: – Service processor Eth0 or HMC1 port is configured as 169.254.2.147 with netmask 255.255.255.0 – Service processor Eth1 or HMC2 port is configured as 169.254.3.147 with netmask 255.255.255.0 More information about the Service Processor can be found in “Service processor” on page 144.
  • 100. 86 IBM Power 720 and 740: Technical Overview and Introduction 2.14.3 HMC high availability The Hardware Management Console (HMC) is an important hardware component. When put into operation, POWER7 processor-based servers and their hosted partitions can continue to operate when no HMC is available. However, in such conditions, certain operations cannot be performed, such as a DLPAR reconfiguration, a partition migration using PowerVM Live Partition Mobility, or the creation of a new partition. You can therefore choose install two HMCs in a redundant configuration so that one HMC is always operational. For example, when performing maintenance of one HMC, the other is still operational. If redundant HMC function is desired, the servers can be attached to two separate HMCs to address availability requirements. Both HMCs must have the same level of Hardware Management Console Licensed Machine Code Version 7 (#0962) to manage POWER7 processor-based servers or an environment with a mixture of POWER5, POWER5+, POWER6, POWER6+ and POWER7 processor-based servers. The HMCs provide a locking mechanism so that only one HMC at a time has write access to the service processor. Depending on your environment, you have multiple options to configure the network. Figure 2-28 shows one possible highly available HMC configuration managing two servers. Each HMC is connected to one FSP port of all managed servers. Figure 2-28 Highly available HMC and network architecture Only the hardware management networks (LAN1 and LAN2) are shown as highly available in this diagram for simplicity. However, the management network (LAN3) can be made highly available by using a similar concept and adding more Ethernet adapters to LPARs and HMCs. Both HMCs must be on a separate VLAN, to protect from a network failure. Each HMC can be a DHCP server for its VLAN. In a configuration with multiple systems or HMCs, the customer is required to provide switches or hubs to connect each HMC to the server FSP Ethernet ports in each system. One HMC must connect to the port labeled as HMC Port 1, and a second HMC must be attached to HMC Port 2. This provides redundant connections for the HMCs and the service processor. HMC1 HMC2 System A System B 1 2 FSP 1 2 FSP LAN 1 LAN 2 LPAR A1 LPAR A2 LPAR A3 LPAR B1 LPAR B2 LPAR B3 eth0eth1 eth0eth1 LAN1 – Hardware management network for first FSP ports (private) LAN2 – Hardware management network for second FSP ports (private), separate network hardware than LAN1 LAN3 - Open network for HMC access and dLPAR operations LAN3 – Open network
  • 101. Chapter 2. Architecture and technical overview 87 For more details about redundant HMCs, see the Hardware Management Console V7 Handbook, SG24-7491. 2.14.4 HMC code level The HMC code must be at level V7R720 in order to support the Power 720 and Power 740 systems. In a dual HMC configuration, both HMCs need to be at the same version and release of the HMC. Here we list two important rules related to HMC code level when using PowerVM Live Partition Mobility: To use PowerVM Live Partition Mobility between a POWER6 processor-based server and a POWER7 processor-based server, if the source server is managed by one HMC and the destination server is managed by another HMC, then ensure that the HMC managing the POWER6 processor-based server is at version 7, release 3.5 or later, and the HMC managing the POWER7 processor-based server is at version 7, release 7.1 or later. To use PowerVM Live Partition Mobility for a partition configured for Active Memory Expansion, ensure that the HMC that manages the destination server is at version 7, release 7.1 or later. 2.15 Integrated Virtualization Manager The Integrated Virtualization Manager (IVM) is a simplified hardware management solution that inherits most of the HMC features. The IVM runs within the Virtual I/O Server partition on the managed server. It manages a single server, avoiding the need of an independent appliance. It is designed to provide a solution that enables the administrator to reduce system setup time and to make hardware management easier, at a lower cost. IVM provides a management model for a single system. Although it does not offer all of the HMC capabilities, it enables the exploitation of PowerVM technology. IVM targets the small and medium systems environment. The following POWER7 processor-based servers can be managed by IVM: Power 710 Tip: When upgrading the code of an HMC in a dual HMC configuration, it is a good practice to disconnect one of the HMCs and avoid having both HMCs connected to the same server with various code levels. If no profile or partition changes take place during the upgrade, both HMCs can stay connected. If the HMCs are at various code levels and a profile change is performed from the HMC at the higher code level, the format of the data stored in the server can change, and the HMC at the lower code level might go into recovery state if it does not understand the new data format. Tip: There are compatibility rules between the various software products that are executing within a POWER7 processor-based server environment: HMC, Virtual I/O Server, system firmware or partition operating systems. To check what combinations are supported, and to identify required upgrades, you can use the Fix Level Tool web page: http://www14.software.ibm.com/webapp/set2/flrt/home
  • 102. 88 IBM Power 720 and 740: Technical Overview and Introduction Power 720 Power 730 Power 740 Power 750 IVM is an addition to the Virtual I/O Server (VIOS), the product that enables I/O virtualization in the family of POWER processor-based systems. The IVM functions are provided by software executing within the Virtual I/O Server partition installed on the server to manage. Note: In order to manage a Power 720 and Power 740 system through IVM, the Virtual I/O Server Version 2.2 is required.
  • 103. Chapter 2. Architecture and technical overview 89 Table 2-30 lists a detailed comparison between the IVM and the HMC functions. Table 2-30 Comparison between IVM and HMC Characteristics and functions IVM HMC General characteristics Delivery Vehicle Integrated into the server A desktop or rack-mounted appliance Installation Installed with the Virtual I/O Server (optical or network). The preinstall option is available on certain systems. Appliance is preinstalled. Reinstall by optical media or network is supported. Multiple system support One IVM per server One HMC can manage multiple servers User Interface Web browser (no local graphical display) and telnet session Web browser (local or remote) or SSH access Scripting and Automation VIOS command line interface (CLI) and HMC compatible CLI HMC command line interface RAS characteristics Redundancy/HA of manager One IVM per server Multiple HMCs can manage the same system for HMC redundancy Multiple VIOS No – single VIOS Yes Fix/Update process for Manager VIOS fixes and updates HMC e-fixes and release updates Adapter microcode updates Inventory scout by RMC Inventory scout by RMC Firmware updates Inband by OS – not concurrent IBM Service Focal Point™ with concurrent firmware maintenance I/O Concurrent Maintenance VIOS support for slot and device level concurrent maintenance by the diag hot plug support Guided support in the “Repair and Verify” function on the HMC Serviceable event management Service Focal Point Light - Consolidated management of firmware and management partition detected errors Service Focal Point support for consolidated management of operating system and firmware detected errors PowerVM function Full PowerVM Capability Partial Full Capacity on Demand Entry of PowerVM codes only Full Support I/O Support for IBM i Virtual Only Virtual and Direct Multiple Shared Processor Pool No - default pool only Yes Workload Management (WLM) Groups Supported One 254
  • 104. 90 IBM Power 720 and 740: Technical Overview and Introduction For a complete description of the possibilities offered by IVM, see Integrated Virtualization Manager on IBM System p5, REDP-4061. 2.15.1 IBM Systems Director Management Console (SDMC) IBM Systems Director Management Console (SDMC) V6.7.3 is the next-generation Hardware Management Console (HMC). The SDMC incorporates the IBM Systems Director software to provide consistency with IBM Systems Director on other platforms. The SDMC is available on physical hardware that is identical to that of the current HMC with additional memory and disk resources. SDMC is also available in a virtual appliance format for managing small-tier servers. The SDMC offers several advantages over the HMC, including the ability to manage both Power Systems servers and Power Systems blades based on Power Architecture®. The SDMC is intended to be used in the same manner as the HMC. It provides the same functionality, including hardware, service, and virtualization management, for your Power Systems server and Power Systems blades. Because SDMC uses IBM Systems Director Express® Edition, it also provides all Systems Director Express capabilities, such as monitoring of operating systems and creating event action plans. The SDMC can be obtained as a hardware appliance in the same manner as an HMC. Hardware appliances support managing Power Systems servers. The SDMC can optionally be obtained in a virtual appliance format, capable of running on VMware (ESX/i 4, or later), and KVM (Red Hat Enterprise Linux® (RHEL) 5.5). The virtual appliance is only supported for managing small-tier Power® servers and Power Systems blades. Much of the SDMC function is equivalent to the HMC. This includes: Server (host) management: Like HMC, the SDMC server (host) management functions include power control, inventory collection, firmware management including concurrent updates, error reporting, dump retrieval and transmission, error reporting via Call Home, and component repair and verify. Virtualization management: Like HMC, the SDMC virtualization management function includes management of logical partitions (virtual servers) and virtual I/ O, Micro-PartitioningTM, Partition (Virtual Server) Mobility, Partition (virtual server) Suspend and Resume, Active MemoryTM Sharing, N_Port ID Virtualization (NPIV), HCA (IB) configuration, and other PowerVMTM capabilities. Transition of configuration data: All partition (virtual server) related information is stored on the managed system itself and will be maintained as is. No configuration changes are required when a client moves from HMC management to SDMC management. Redundancy and high availability: The SDMC offers console redundancy similar to the HMC. The SDMC may be used in either an SDMC-SDMC pair or an SDMC- HMC pair. Alternatively, the SDMC may be configured as an Active-Passive High Availability pair. The Active-Passive HA function provides high availability for Systems Director operating system management functions. Support for multiple profiles per partition No Yes SysPlan Deploy & mksysplan Yes Yes Characteristics and functions IVM HMC
  • 105. Chapter 2. Architecture and technical overview 91 While most functions that SDMC provides are very similar to that of the HMC, the SDMC has made significant strides in simplifying virtualization management. Specifically, managing virtual I/O has become much simpler as SDMC can automatically create virtual I/O adapters, and allow the user to assign virtual storage directly to partitions (virtual servers). SDMC provides a more intuitive interface for dynamically managing the resources currently assigned to a partition (virtual server), by combining the HMC DLPAR functions with partition (virtual server) properties. SDMC also allows partition (virtual server) modifications independent of the partition (virtual server) state. Another significant enhancement is the ability of the SDMC to manage Power Systems blades. While IVM is still a choice for Power Systems blade management, clients choosing SDMC management of blades can take advantage of multiple Virtual I/O Servers, multiple shared processor pools, Active Memory Expansion, Partition (virtual server) Suspend and Resume, and many other PowerVM capabilities. Because SDMC uses Systems Director, you can take advantage of all that Systems Director Express Edition has to offer with respect to managing Power Systems servers and blades. Highlights include: Operating system management: Use SDMC to discover and directly manage your operating systems. Event automation plans: Create automation plans that perform specific functions on a given event. For example, when the CPU utilization exceeds a given threshold, an email notification can be sent to an administrator. Dashboard: The SDMC provides a dashboard with health and status. Monitoring: Systems Director brings a richer set of monitoring functions to the management console. Common look and feel of the IBM Systems Director portfolio family. The Systems Director Management Console Virtual Appliance (5765-MCV) does not include support for the customer-installed hypervisor. If you use the SDMC Virtual Appliance, you will need to purchase KVM or VMware support separately if you want to have support for your hypervisor. Migration, updates, and compatibility: IBM does not support upgrades or conversions from existing CR5/CR6 hardware-based Hardware Management Consoles to the Systems Director Management Console. Differences from HMC: The following functions provided by the HMC are not provided by the SDMC: modem support and VPN call home. Also, POWER5 technology-based servers are not supported by the SDMC. For a complete description of the possibilities offered by SDMC, see IBM Systems Director Management Console: Introduction and Overview, SG24-7860-00 available at web page: http://www.redbooks.ibm.com/abstracts/sg247860.html?Open 2.16 Operating system support The IBM POWER7 processor-based systems support three families of operating systems: AIX IBM i Linux
  • 106. 92 IBM Power 720 and 740: Technical Overview and Introduction In addition, the Virtual I/O Server can be installed in special partitions that provide support to the other operating systems for using features such as virtualized I/O devices, PowerVM Live Partition Mobility, and/or PowerVM Active Memory Sharing. 2.16.1 Virtual I/O Server The minimum required level of Virtual I/O Server software depends on the server model: Power 710 and 730 Virtual I/O Server Version 2.2, or later Power 720 and 740 Virtual I/O Server Version 2.2, or later Power 750 Virtual I/O Server Version 2.1.2.11 with Fix Pack 22.1 and Service Pack 1 Power 755 The Virtual I/O Server feature is not available on this model. Power 770 and 780 Virtual I/O Server Version 2.1.2.12 with Fix Pack 22.1 and Service Pack 2 Power 795 Virtual I/O Server Version 2.2, or later IBM regularly updates the Virtual I/O Server code. To find information about the latest updates, visit the Virtual I/O Server site: http://www14.software.ibm.com/webapp/set2/sas/f/vios/documentation/home.html 2.16.2 IBM AIX operating system The following sections discuss the support for the various levels of AIX operating system support. IBM periodically releases maintenance packages (service packs or technology levels) for the AIX operating system. Information about these packages, downloading, and obtaining the CD-ROM is on the Fix Central Web site: http://www-933.ibm.com/support/fixcentral/ The Fix Central Web site also provides information about ho to obtain the fixes shipping on CD-ROM. The Service Update Management Assistant, which can help you to automate the task of checking and downloading operating system downloads, is part of the base operating system. For more information about the suma command, go to following Web site: http://www14.software.ibm.com/webapp/set2/sas/f/genunix/suma.html IBM AIX Version 5.3 IBM AIX Version 5.3 is supported on all models of POWER7 processor-based servers delivered in 2010. The minimum level of AIX Version 5.3 to support the Power 710, 720, 730, and 740 is: AIX 5.3 with the 5300-10 Technology Level and Service Pack 5, or later AIX 5.3 with the 5300-11 Technology Level and Service Pack 5, or later Note: For details about the software available on IBM POWER servers, visit the Power Systems Software™ site: http://www.ibm.com/systems/power/software/index.html
  • 107. Chapter 2. Architecture and technical overview 93 AIX 5.3 with the 5300-12 Technology Level and Service Pack 2, or later The minimum level of AIX Version 5.3 to support the Power 750, 755, 770, and 780 is: AIX 5.3 with the 5300-09 Technology Level and Service Pack 7, or later AIX 5.3 with the 5300-10 Technology Level and Service Pack 4, or later AIX 5.3 with the 5300-11 Technology Level and Service Pack 2, or later The minimum level of AIX Version 5.3 to support the Power 795 is: AIX 5.3 with the 5300-10 Technology Level and Service Pack 5, or later AIX 5.3 with the 5300-11 Technology Level and Service Pack 5, or later AIX 5.3 with the 5300-12 Technology Level and Service Pack 1, or later A partition using AIX Version 5.3 will be executing in POWER6 or POWER6+ compatibility mode. This means that although the POWER7 processor has the ability to run four hardware threads per core simultaneously, using AIX 5.3 limits the number of hardware threads per core to two. A partition with AIX 5.3 is limited to a maximum of 64 cores. IBM AIX Version 6.1 If you install AIX 6.1 on a POWER7 processor-based server, the minimum level requirements depend on the target server model: The minimum level of AIX Version 6.1 to support the Power 710, 720, 730, 740, and 795 is: AIX 6.1 with the 6100-04 Technology Level and Service Pack 7, or later AIX 6.1 with the 6100-05 Technology Level and Service Pack 3, or later AIX 6,1 with the 6100-06 Technology Level The minimum level of AIX Version 6.1 to support the Power 750 and 755 is: AIX 6.1 with the 6100-02 Technology Level and Service Pack 8, or later AIX 6.1 with the 6100-03 Technology Level and Service Pack 5, or later AIX 6.1 with the 6100-04 Technology Level and Service Pack 2, or later The minimum level of AIX Version 6.1 to support the Power 770 and 780 is: AIX 6.1 with the 6100-02 Technology Level and Service Pack 8, or later AIX 6.1 with the 6100-03 Technology Level and Service Pack 5, or later AIX 6.1 with the 6100-04 Technology Level and Service Pack 3, or later A partition using AIX 6.1 with TL6 can run in POWER6, POWER6+ or POWER7 mode. It is best to run the partition in POWER7 mode to allow exploitation of new hardware capabilities such as SMT4 and Active Memory Expansion (AME). A partition with AIX 6.1 is limited to a maximum of 64 cores. IBM AIX Version 7.1 AIX Version 7.1 comes will full support for the Power 710, 720, 730, 740, 750, 755, 770, 780, and 795, exploiting all the hardware features from the POWER7 processor, as well as from the server architecture. A partition with AIX 7.1 can run in POWER6, POWER6+ or POWER7 mode, to enable Live Partition Mobility to different POWER6 and POWER7 systems. When
  • 108. 94 IBM Power 720 and 740: Technical Overview and Introduction running in POWER7 mode, a partition with AIX 7.1 can scale up to 256 cores and 8 TB of RAM. 2.16.3 IBM i operating system The IBM i operating system is supported on Power 710, 720, 730, 740, 750, 770, 780, and 795 at the following minimum levels: IBM i Version 6.1 with i 6.1.1 machine code, or later IBM i Version 7.1, or later IBM i Standard Edition, and Application Server Edition options are available the Power 740, 750, 770, 780, and 795. IBM i Standard Edition offers an integrated operating environment for business processing IBM i Application Server Edition offers IBM i without DB2 for application and infrastructure serving. IBM i is not supported on Power 755. IBM periodically releases maintenance packages (service packs or technology levels) for the IBM i operating system. Information about these packages, downloading, and obtaining the CD-ROM is on the Fix Central Web site: http://www-933.ibm.com/support/fixcentral/ 2.16.4 Linux operating system Linux is an open source operating system that runs on numerous platforms from embedded systems to mainframe computers. It provides a UNIX-like implementation across many computer architectures. The supported versions of Linux on POWER7 processor-based servers are: SUSE Linux Enterprise Server 10 with SP3, enabled to run in POWER6 Compatibility mode SUSE Linux Enterprise Server 11, supporting POWER6 or POWER7 mode Red Hat Enterprise Linux AP 5 Update 5 for POWER, or later Clients wanting to configure Linux partitions in virtualized Power Systems have to be aware of these conditions: Not all devices and features that are supported by the AIX operating system are supported in logical partitions running the Linux operating system. Linux operating system licenses are ordered separately from the hardware. You may acquire Linux operating system licenses from IBM, to be included with the POWER7 processor-based servers, or from other Linux distributors. Note: Partition sizes greater than 128-cores (up to 256-cores) will require a software key to enable. Purchase will require lab services pre-analysis as a prerequisite to shipment. The software key requires feature #1256 to be installed.
  • 109. Chapter 2. Architecture and technical overview 95 For information about the features and external devices supported by Linux, go to: http://www.ibm.com/systems/p/os/linux/index.html For information about SUSE Linux Enterprise Server 10, go to: http://www.novell.com/products/server For information about Red Hat Enterprise Linux Advanced Server, go to: http://www.redhat.com/rhel/features Supported virtualization features are listed in 3.5.9, “Operating System support for PowerVM”. 2.17 Compiler technology You can boost performance and productivity with IBM compilers on IBM Power Systems. IBM XL C, XL C/C++ and XL FORTRAN compilers for AIX and for Linux exploit the latest POWER7 processor architecture. Release after release, these compilers continue to help improve application performance and capability, exploiting architectural enhancements made available through the advancement of the POWER® technology. IBM compilers are designed to optimize and tune your applications for execution on IBM POWER platforms, to help you unleash the full power of your IT investment, to create and maintain critical business and scientific applications, to maximize application performance, and to improve developer productivity. The performance gain from years of compiler optimization experience is seen in the continuous release-to-release compiler improvements that support the POWER4 processors, through to the POWER4+, POWER5, POWER5+ and POWER6 processors, and now including the new POWER7 processors. With the support of the latest POWER7 processor chip, IBM advances a more than 20-year investment in the XL compilers for POWER series and PowerPC series architectures. The XL C, XL C/C++ and XL FORTRAN features introduced to exploit the latest POWER7 processor include vector unit and vector scalar extension (VSX) instruction set to efficiently manipulate vector operations in your application, vector functions within the Mathematical Acceleration Subsystem (MASS) libraries for improved application performance, built-in functions or intrinsics and directives for direct control of POWER instructions at the application level, and architecture and tuning compiler options to optimize and tune your applications. COBOL for AIX enables you to selectively target code generation of your programs to either exploit POWER7 systems architecture or to be balanced among all supported POWER systems. The performance of COBOL for AIX applications is improved by means of an enhanced back-end optimizer. The back-end optimizer, a component common also to the IBM XL compilers, lets your applications leverage the latest industry-leading optimization technology. PL/I for AIX supports application development on the latest POWER7 processor. IBM Rational® Development Studio for IBM i 7.1 provides programming languages for creating modern business applications. This includes the ILE RPG, ILE COBOL, C, and C++ compilers as well as the heritage RPG and COBOL compilers. The latest release includes performance improvements and XML processing enhancements for ILE RPG and ILE COBOL, improved COBOL portability with a new COMP-5 data type, and easier Unicode migration with relaxed USC2 rules in ILE RPG. Rational has also released a new product
  • 110. 96 IBM Power 720 and 740: Technical Overview and Introduction called Rational Open Access: RPG Edition. This opens up the ILE RPG file I/O processing, enabling partners, tool providers, and users to write custom I/O handlers that can access other devices such as databases, services, and Web user interfaces. IBM Rational Developer for Power Systems Software provides a rich set of integrated development tools that support the XL C/C++ for AIX compiler, the XL C for AIX compiler and the COBOL for AIX compiler. Rational Developer for Power Systems Software offers capabilities of file management, searching, editing, analysis, build, and debug, all integrated into an Eclipse workbench. XL C/C++, XL C and COBOL for AIX developers can boost productivity by moving from older, text-based, command line development tools to a rich set of integrated development tools. IBM Rational Power Appliance is a preconfigured application development environment solution for Power Systems, which includes a Power Express server preinstalled with a comprehensive set of Rational development software along with the AIX operating system. The Rational development software includes support for Collaborative Application Lifecycle Management (C/ALM) through Rational Team Concert for Power Systems Software, a set of software development tools from Rational Developer for Power Systems Software, and a choice between the XL C/C++ for AIX or COBOL for AIX compilers. 2.18 Energy management The Power 720 and 740 servers are designed with features to help clients become more energy efficient. The IBM Systems Director Active Energy Manager exploits EnergyScale technology, enabling advanced energy management features to dramatically and dynamically conserve power and further improve energy efficiency. Intelligent Energy optimization capabilities enable the POWER7 processor to operate at a higher frequency for increased performance and performance per watt or dramatically reduce frequency to save energy. 2.18.1 IBM EnergyScale technology IBM EnergyScale technology provides functions to help the user understand and dynamically optimize the processor performance versus processor energy consumption, and system workload, to control IBM Power Systems power and cooling usage. On POWER7 processor-based systems, the thermal power management device (TPMD) card is responsible for collecting the data from all system components, changing operational parameters in components, and to interact with the IBM Systems Director Active Energy Manager (an IBM Systems Directors plug-in) for energy management and control. IBM EnergyScale makes use of power and thermal information collected from the system in order to implement policies that can lead to better performance, or better energy utilization. IBM EnergyScale features include: Power trending EnergyScale provides continuous collection of real-time server energy consumption. This enables administrators to predict power consumption across their infrastructure and to react to business and processing needs. For example, administrators can use such information to predict datacenter energy consumption at various times of the day, week, or month.
  • 111. Chapter 2. Architecture and technical overview 97 Thermal reporting IBM Director Active Energy Manager can display measured ambient temperature and calculated exhaust heat index temperature. This information can help identify data center hot spots that need attention. Power Saver Mode Power Saver Mode lowers the processor frequency and voltage on a fixed amount, reducing the energy consumption of the system while still delivering predictable performance. This percentage is predetermined to be within a safe operating limit and is not user configurable. The server is designed for a fixed frequency drop of up to 30% down from nominal frequency (the actual value depends on the server type and configuration). Power Saver Mode is not supported during boot or re-boot although it is a persistent condition that will be sustained after the boot when the system starts executing instructions. Dynamic Power Saver Mode Dynamic Power Saver Mode varies processor frequency and voltage based on the utilization of the POWER7 processors. Processor frequency and utilization are inversely proportional for most workloads, implying that as the frequency of a processor increases, its utilization decreases, given a constant workload.Dynamic Power Saver Mode takes advantage of this relationship to detect opportunities to save power, based on measured real-time system utilization. When a system is idle, the system firmware will lower the frequency and voltage to Power Energy Saver Mode values. When fully utilized, the maximum frequency will vary, depending on whether the user favors power savings or system performance. If an administrator prefers energy savings and a system is fully-utilized, the system is designed to reduce the maximum frequency to 95% of nominal values. If performance is favored over energy consumption, the maximum frequency can be increased to up to 109% of nominal frequency for extra performance. Dynamic Power Saver Mode is mutually exclusive with Power Saver mode. Only one of these modes can be enabled at a given time. Power Capping Power Capping enforces a user-specified limit on power usage. Power Capping is not a power saving mechanism. It enforces power caps by actually throttling the processors in the system, degrading performance significantly. The idea of a power cap is to set a limit that must never be reached but frees up extra power never used in the data center. The margined power is this amount of extra power that is allocated to a server during its installation in a datacenter. It is based on the server environmental specifications that usually are never reached because server specifications are always based on maximum configurations and worst case scenarios. The user must set and enable an energy cap from the IBM Director Active Energy Manager user interface. Soft Power Capping There are two power ranges into which the power cap can be set; one is Power Capping as described before, and the other is Soft Power Capping. Soft Power Capping extends the allowed energy capping range further, beyond a region that can be guaranteed in all configurations and conditions. If the energy management goal is to meet a particular consumption limit, then Soft Power Capping is the mechanism to use.
  • 112. 98 IBM Power 720 and 740: Technical Overview and Introduction Processor Core Nap Mode The IBM POWER7 processor uses a low-power mode called Nap that stops processor execution when there is no work to do on that processor core. The latency of exiting Nap is very small, typically not generating any impact on applications running. Because of that, the POWER Hypervisor can use the Nap mode as a general purpose idle state. When the operating system detects that a processor thread is idle, it yields control of a hardware thread to the POWER Hypervisor. The POWER Hypervisor immediately puts the thread into Nap mode. Nap mode allows the hardware to turn the clock off on most of the circuits inside the processor core. Reducing active energy consumption by turning off the clocks allows the temperature to fall, which further reduces leakage (static) power of the circuits causing a cumulative effect. Nap mode saves from 10-15% of power consumption in the processor core. Processor core Sleep Mode To be able to save even more energy, the POWER7 processor has an even lower power mode called Sleep. Before a core and its associated L2 and L3 caches enter Sleep mode, caches are flushed and transition lookaside buffers (TLB) are invalidated, and hardware clock is turned off in the core and in the caches. Voltage is reduced in order to minimize leakage current. Processor cores inactive in the system (such as CoD processor cores) are kept in Sleep mode. Sleep mode saves about 35% power consumption in the processor core and associated L2 and L3 caches. Fan control and altitude input System firmware will dynamically adjust fan speed based on energy consumption, altitude, ambient temperature, and energy savings modes. Power Systems are designed to operate in worst-case environments, in hot ambient temperatures, at high altitudes, and with high power components. In a typical case, one or more of these constraints are not valid. When no power savings setting is enabled, fan speed is based on ambient temperature, and assumes a high-altitude environment. When a power savings setting is enforced (either Power Energy Saver Mode or Dynamic Power Saver Mode), fan speed will vary based on power consumption, ambient temperature, and altitude available. System altitude can be set in IBM Director Active Energy Manager. If no altitude is set, the system will assume a default value of 350 meters above sea level. Processor Folding Processor Folding is a consolidation technique that dynamically adjusts, over the short-term, the number of processors available for dispatch to match the number of processors demanded by the workload. As the workload increases, the number of processors made available increases; as the workload decreases, the number of processors made available decreases. Processor Folding increases energy savings during periods of low to moderate workload because unavailable processors remain in low-power idle states (Nap or Sleep) longer. EnergyScale for I/O IBM POWER7 processor-based systems automatically power off hot pluggable, PCI adapter slots that are empty or not being used. System firmware automatically scans all pluggable PCI slots at regular intervals, looking for those that meet the criteria for being not in use and powering them off. This support is available for all POWER7 processor-based servers, and the expansion units that they support. Server Power Down If overall data center processor utilization is low, workloads can be consolidated on fewer numbers of servers so that some servers can be turned off completely. It makes sense to do this when there will be long periods of low utilization, such as weekends. AEM provides
  • 113. Chapter 2. Architecture and technical overview 99 information, such as the power that will be saved and the time it will take to bring a server back online, that can be used to help make the decision to consolidate and power off. As with many of the features available in IBM Systems Director and Active Energy Manager, this function is scriptable and can be automated. Partition Power Management Available with Active Energy Manager 4.3.1 or newer, and POWER7 systems with EM730 firmware or newer, is the capability to set a power savings mode for partitions or the system processor pool. As ith the system-level power savings modes, the per-partition power savings modes can be used to achieve a balance between the power consumption and the performance of a partition. Only partitions that have dedicated processing units can have a unique power savings setting. Partitions that run in shared processing mode will have a common power savings setting, which is that of the system processor pool. This is because processing unit fractions cannot be power-managed. As in the case of system-level power savings, two Dynamic Power Saver options are offered: favor partition performance, or favor partition power savings. The user must configure this setting from Active Energy Manager. When Dynamic Power Saver is enabled in either mode, system firmware continuously monitors the performance and utilization of each of the computer's POWER7 processor cores that belong to the partition. Based on this utilization and performance data, the firmware will dynamically adjust the processor frequency and voltage, reacting within milliseconds to adjust workload performance and also deliver power savings when the partition is under-utilized. In addition to the two Dynamic Power Saver options, the customer can select to have no power savings on a given partition. This option will leave the processor cores assigned to the partition running at their nominal frequencies and voltages. A new power savings mode, called “Inherit Host Setting”, is available and is only applicable to partitions. When configured to use this setting, a partition will adopt the power savings mode of its hosting server. By default, all partitions with dedicated processing units, and the system processor pool, are set to Inherit Host Setting. On POWER7 processor-based systems, several EnergyScales are imbedded in the hardware and do not require an operating system or external management component. More advanced functionality requires Active Energy Manager (AEM) and IBM Systems Director. Table 2-31 provides a list of all features actually supported, underlining all cases where AEM is not required. The table details also the features that can be activated by traditional user interfaces (ASMI, HMC). Table 2-31 AEM support Feature Active Energy Manager (AEM) required ASMI HMC Power Trending Y N N Thermal Reporting Y N N Static Power Saver N Y Y Dynamic Power Saver Y N N Power Capping Y N N Energy-optimized Fans N - - Processor Core Nap N - -
  • 114. 100 IBM Power 720 and 740: Technical Overview and Introduction The Power 720 and Power 740 systems implement all the Energy Scale capabilities listed in 2.18.1, “IBM EnergyScale technology” on page 96. 2.18.2 Thermal power management device card The thermal power management device (TPMD) card is a separate microcontroller installed on some POWER6 processor-based systems, and in all POWER7 processor-based systems. It runs real-time firmware whose sole purpose is to manage system energy. The TPMD card monitors the processor modules, memory, environmental temperature, and fan speed; and based on this information, it can act upon the system to maintain optimal power and energy conditions (for example, increase the fan speed to react to a temperature change). It also interacts with the IBM Systems Director Active Energy Manager to report power and thermal information, and to receive input from AEM on policies to be set. The TPMD is part of the EnergyScale infrastructure. Processor Core Sleep N - - Processor Folding N - - EnergyScale for I/O N - - Server Power Down Y - - Partition Power Management Y - - Feature Active Energy Manager (AEM) required ASMI HMC
  • 115. © Copyright IBM Corp. 2010. All rights reserved. 101 Chapter 3. Virtualization As you look for ways to maximize the return on your IT infrastructure investments, consolidating workloads becomes an attractive proposition. IBM Power Systems combined with PowerVM technology are designed to help you consolidate and simplify your IT environment, with the following key capabilities: Improve server utilization and sharing I/O resources to reduce total cost of ownership and make better use of IT assets. Improve business responsiveness and operational speed by dynamically re-allocating resources to applications as needed — to better match changing business needs or handle unexpected changes in demand. Simplify IT infrastructure management by making workloads independent of hardware resources, thereby enabling you to make business-driven policies to deliver resources based on time, cost, and service-level requirements. This chapter discusses the virtualization technologies and features on IBM Power Systems: POWER Hypervisor POWER Modes Partitioning Active Memory Expansion PowerVM System Planning Tool 3
  • 116. 102 IBM Power 720 and 740: Technical Overview and Introduction 3.1 POWER Version 2.2 enhancements The latest available PowerVM Version 2.2 contains the following enhancements: Support for up to 80 LPARs on Power 710 and 720 Support for up to 160 LPARs on Power 730, 740, Support for up to 320 LPARs on Power 750, Support for up to 640 LPARs on Power 770 and 780 Support for up to 1024 LPARs on Power 795 PowerVM support for sub-chip per-core licensing on Power 710, 720, 730, and 740 Role Based Access Control (RBAC): RBAC brings an added level of security and flexibility in the administration of VIOS. With RBAC, you can create a set of authorizations for the user management commands. You can assign these authorizations to a role UserManagement and this role can be given to any other user. So a normal user with the role UserManagement can manage the users on the system but will not have any further access. With RBAC, the Virtual I/O Server has the capability of split management functions that presently can be done only by the padmin user, providing better security by giving only the necessary access to users, and easy management and auditing of system functions. Support for Concurrent Add of VLANs Support for USB tape: The Virtual I/O Server now supports a USB DAT-320 Tape Drive and its use as a virtual tape device for VIOS clients. Support for USB Blu-ray: The Virtual I/O Server now supports USB Blu-ray optical devices. AIX does not support mapping these as virtual optical devices to clients. However, you can import the disk into the virtual optical media library and map the created file to the client as a virtual DVD drive. The IBM PowerVM Workload Partitions Manager™ for AIX, Version 2.2 has the following enhancements: When used with AIX 6.1 Technology Level 6, the following support applies: – Support for exporting VIOS SCSI disk into a WPAR. Compatibility analysis and mobility of WPARs with VIOS SCSI disk. In addition to Fibre Channel devices, now VIOS SCSI disks can be exported into a workload partition (WPAR). – WPAR Manager Command-Line Interface (CLI). The WPAR Manager CLI allows federated management of WPARs across multiple systems by command line. – Support for workload partition definitions. The WPAR definitions can be preserved after WPARs are deleted. These definitions can be deployed at a later time to any WPAR-capable system. In addition to the feature supported on AIX 6.1 Technology Level 6, the following applies to AIX 7.1: – Support for AIX 5.2 Workload Partitions for AIX 7.1. Life cycle management and mobility enablement for AIX 5.2 Technology Level 10 SP8 Version WPARs. – Support for trusted kernel extension loading and configuration from WPARs. Enables exporting a list of kernel extensions that can then be loaded inside a WPAR, yet maintaining isolation.
  • 117. Chapter 3. Virtualization 103 3.2 POWER Hypervisor Combined with features designed into the POWER7 processors, the POWER Hypervisor delivers functions that enable other system technologies, including logical partitioning technology, virtualized processors, IEEE VLAN compatible virtual switch, virtual SCSI adapters, virtual Fibre Channel adapters, and virtual consoles. The POWER Hypervisor is a basic component of the system’s firmware and offers the following functions: Provides an abstraction between the physical hardware resources and the logical partitions that use them Enforces partition integrity by providing a security layer between logical partitions Controls the dispatch of virtual processors to physical processors (see “Processing Mode” on page 114) Saves and restores all processor state information during a logical processor context switch Controls hardware I/O interrupt management facilities for logical partitions Provides virtual LAN channels between logical partitions that help to reduce the need for physical Ethernet adapters for inter-partition communication Monitors the Service Processor and will perform a reset/reload if it detects the loss of the Service Processor, notifying the operating system if the problem is not corrected The POWER Hypervisor is always active, regardless of the system configuration and also when not connected to the HMC. It requires memory to support the resource assignment to the logical partitions on the server. The amount of memory required by the POWER Hypervisor firmware varies according to several factors. Here we list factors influencing the POWER Hypervisor memory requirements: Number of logical partitions Number of physical and virtual I/O devices used by the logical partitions Maximum memory values specified in the logical partition profiles The minimum amount of physical memory to create a partition is the size of the system’s Logical Memory Block (LMB). The default LMB size varies according to the amount of memory configured in the CEC as shown in Table 3-1. Table 3-1 Configured CEC memory-to-default Logical Memory Block size But in most cases, the actual minimum requirements and preferable capacities of the supported operating systems are above 256 MB. Physical memory is assigned to partitions in increments of Logical Memory Block. The POWER Hypervisor provides the following types of virtual I/O adapters: Virtual SCSI Virtual Ethernet Virtual Fibre Channel Virtual (TTY) console Configurable CEC memory Default Logical Memory Block Greater than 8 GB up to 16 GB 64 MB Greater than 16 GB up to 32 GB 128 MB Greater than 32 GB 256 MB
  • 118. 104 IBM Power 720 and 740: Technical Overview and Introduction 3.2.1 Virtual SCSI The POWER Hypervisor provides a virtual SCSI mechanism for virtualization of storage devices. The storage virtualization is accomplished using two, paired, adapters: a virtual SCSI server adapter and a virtual SCSI client adapter. A Virtual I/O Server partition or a IBM i partition can define virtual SCSI server adapters, other partitions are client partitions. The Virtual I/O server partition is a special logical partition, as described in 3.5.4, “Virtual I/O Server” on page 119. The Virtual I/O Server software is available with the optional PowerVM Edition features. 3.2.2 Virtual Ethernet The POWER Hypervisor provides a virtual Ethernet switch function that allows partitions on the same server to use a fast and secure communication without any need for physical interconnection. The virtual Ethernet allows a transmission speed in the range of 1 to 3 Gbps. depending on the MTU1 size and CPU entitlement. Virtual Ethernet support starts with AIX Version 5.3, or appropriate level of Linux supporting Virtual Ethernet devices (see 3.5.9, “Operating System support for PowerVM” on page 126). The virtual Ethernet is part of the base system configuration. Virtual Ethernet has the following major features: The virtual Ethernet adapters can be used for both IPv4 and IPv6 communication and can transmit packets with a size up to 65408 bytes. Therefore, the maximum MTU for the corresponding interface can be up to 65394 (65390 if VLAN tagging is used). The POWER Hypervisor presents itself to partitions as a virtual 802.1Q compliant switch. The maximum number of VLANs is 4096. Virtual Ethernet adapters can be configured as either untagged or tagged (following the IEEE 802.1Q VLAN standard). A partition supports 256 virtual Ethernet adapters. Besides a default port VLAN ID, the number of additional VLAN ID values that can be assigned per Virtual Ethernet adapter is 20, which implies that each Virtual Ethernet adapter can be used to access 21 virtual networks. Each partition operating system detects the virtual local area network (VLAN) switch as an Ethernet adapter without the physical link properties and asynchronous data transmit operations. Any virtual Ethernet can also have connectivity outside of the server if a layer-2 bridge to a physical Ethernet adapter is set in one Virtual I/O server partition (see 3.5.4, “Virtual I/O Server” on page 119 for more details about shared Ethernet). This is also known as Shared Ethernet Adapter. 1 Maximum transmission unit Note: Virtual Ethernet is based on the IEEE 802.1Q VLAN standard. No physical I/O adapter is required when creating a VLAN connection between partitions, and no access to an outside network is required.
  • 119. Chapter 3. Virtualization 105 3.2.3 Virtual Fibre Channel A virtual Fibre Channel adapter is a virtual adapter that provides client logical partitions with a Fibre Channel connection to a storage area network through the Virtual I/O Server logical partition. The Virtual I/O Server logical partition provides the connection between the virtual Fibre Channel adapters on the Virtual I/O Server logical partition and the physical Fibre Channel adapters on the managed system. Figure 3-1 depicts the connections between the client partition virtual Fibre Channel adapters and the external storage. For additional information, see 3.5.8, “NPIV” on page 126. Figure 3-1 Connectivity between virtual Fibre Channels adapters and external SAN devices 3.2.4 Virtual (TTY) console Each partition needs to have access to a system console. Tasks such as operating system installation, network setup, and some problem analysis activities require a dedicated system console. The POWER Hypervisor provides the virtual console using a virtual TTY or serial adapter and a set of Hypervisor calls to operate on them. Virtual TTY does not require the purchase of any additional features or software such as the PowerVM Edition features. Depending on the system configuration, the operating system console can be provided by the Hardware Management Console virtual TTY, IVM virtual TTY, or from a terminal emulator that is connected to a system port. Virtual I/O Server Server virtual Fibre Channel adapter Server virtual Fibre Channel adapter Server virtual Fibre Channel adapter Physical Fibre Channel adapter Storage Area Network Physical Storage 1 Physical Storage 2 Physical Storage 3 Client logical Partition 1 Client virtual Fibre Channel adapter Client logical Partition 2 Client virtual Fibre Channel adapter Client logical Partition 3 Client virtual Fibre Channel adapter Hypervisor
  • 120. 106 IBM Power 720 and 740: Technical Overview and Introduction 3.3 POWER processor modes Although not a virtualization feature, strictly speaking, POWER modes are described here because they have an impact on some virtualization features. On any Power Systems server, partitions can be configured to run in various modes: POWER6 compatibility mode: This execution mode is compatible with Version 2.05 of the Power Instruction Set Architecture (ISA). http://www.power.org/resources/reading/PowerISA_V2.05.pdf POWER6+ compatibility mode: This mode is similar to the POWER6 compatibility mode, with eight additional Storage Protection Keys. POWER7 mode: This is the native mode for POWER7 processors, implementing the v2.06 of the Power Instruction Set Architecture. http://www.power.org/resources/downloads/PowerISA_V2.06_PUBLIC.pdf The selection of the mode is made on a per partition basis, from the HMC, by editing the partition profile as presented in Figure 3-2. Figure 3-2 Configuring partition profile compatibility mode from the HMC
  • 121. Chapter 3. Virtualization 107 Table 3-2 lists the differences between these modes. Table 3-2 Differences between POWER6 and POWER7 mode 3.4 Active Memory Expansion Active Memory Expansion is an innovative POWER7 technology that allows the effective maximum memory capacity to be much larger than the true physical memory maximum. Compression and decompression of memory content can allow memory expansion up to 100%. This can allow a partition to do significantly more work or support more users with the same physical amount of memory. Similarly, it can allow a server to run more partitions and do more work for the same physical amount of memory. Active Memory Expansion enablement is an optional hardware feature of POWER7 processor-based servers, that must be specified when creating the configuration in the e-config tool: IBM Power 720 #4793 IBM Power 740 #4794 Active Memory Expansion is available for partitions running AIX 6.1, Technology Level 4 with SP2, or later. POWER6 mode (and POWER6+) POWER7 mode Customer value 2-thread SMT 4-thread SMT Throughputperformance,processor core utilization VMX (Vector Multimedia Extension / AltiVec) VSX (Vector Scalar Extension) High performance computing Affinity OFF by default 3-tier memory, Micropartition Affinity Improved system performance for system images spanning sockets and nodes. Barrier Synchronization Fixed 128-byte Array; Kernel Extension Access Enhanced Barrier Synchronization Variable Sized Array; User Shared Memory Access High performance computing parallel programming synchronization facility 64-core/128-thread Scaling 32-core / 128-thread Scaling 64-core / 256-thread Scaling 256-core / 1024-thread Scaling Performance and Scalability for Large Scale-Up Single System Image Workloads (for example, OLTP, ERP scale-up, WPAR consolidation) EnergyScale CPU Idle EnergyScale CPU Idle and Folding with NAP and SLEEP Improved Energy Efficiency
  • 122. 108 IBM Power 720 and 740: Technical Overview and Introduction Active Memory Expansion uses CPU resource of a partition to compress/decompress the memory contents of this same partition. The trade off of memory capacity for processor cycles can be an excellent choice, but the degree of expansion varies based on how compressible the memory content is, and it also depends on having adequate spare CPU capacity available for this compression/decompression. Tests in IBM laboratories using sample work loads showed excellent results for many workloads in terms of memory expansion per additional CPU utilized. Other test workloads had more modest results. Clients have a great deal of control over Active Memory Expansion usage. Each individual AIX partition can turn on or turn off Active Memory Expansion. Control parameters set the amount of expansion desired in each partition to help control the amount of CPU used by the Active Memory Expansion function. An IPL is required for the specific partition that is turning memory expansion on or off. After being turned on, there are monitoring capabilities in standard AIX performance tools such as lparstat, vmstat, topas, and svmon. Figure 3-3 represents the percentage of CPU used to compress memory for two partitions with various profiles. The green curve corresponds to a partition that has spare processing power capacity, while the blue curve corresponds to a partition constrained in processing power. Figure 3-3 CPU usage versus memory expansion effectiveness Both cases shows that there is a knee-of-curve relationship for CPU resource required for memory expansion: Busy processor cores do not have resources to spare for expansion. The more memory expansion is done, the more CPU resource is required. The knee varies depending on how compressible memory contents are. This demonstrates the need for a case by case study of whether memory expansion can provide a positive return on investment. To help you perform this study, a planning tool is included with AIX 6.1 Technology Level 4 allowing you to sample actual workloads and estimate both how expandable the partition's memory is and how much CPU resource is needed. Any model Power System can run the planning tool. Figure 3-4 on page 109 shows an example of the output returned by this planning tool. The tool outputs various real memory and CPU resource combinations to achieve the desired effective memory and indicates one particular combination. In this example, the tool proposes to allocate 58% of a processor core, to benefit from 45% extra memory capacity. % CPU utilization for expansion Amount of memory expansion 1 = Plenty of spare CPU resource available 2 = Constrained CPU resource – already running at significant utilization 1 2 Very cost effective
  • 123. Chapter 3. Virtualization 109 Figure 3-4 Output form Active Memory Expansion planning tool When you have selected the value of the memory expansion factor you want to achieve, you can use this value to configure the partition from the HMC, as shown in Figure 3-5. Figure 3-5 Using the planning tool result to configure the partition Active Memory Expansion Modeled Statistics: ----------------------- Modeled Expanded Memory Size : 8.00 GB Expansion True Memory Modeled Memory CPU Usage Factor Modeled Size Gain Estimate --------- -------------- ----------------- ----------- 1.21 6.75 GB 1.25 GB [ 19%] 0.00 1.31 6.25 GB 1.75 GB [ 28%] 0.20 1.41 5.75 GB 2.25 GB [ 39%] 0.35 1.51 5.50 GB 2.50 GB[ 45%] 0.58 1.61 5.00 GB 3.00 GB [ 60%] 1.46 Active Memory Expansion Recommendation: --------------------- The recommended AME configuration for this workload is to configure the LPAR with a memory size of 5.50 GB and to configure a memory expansion factor of 1.51. This will result in a memory expansion of 45% from the LPAR's current memory size. With this configuration, the estimated CPU usage due to Active Memory Expansion is approximately 0.58 physical processors, and the estimated overall peak CPU resource required for the LPAR is 3.72 physical processors. 5.5 true 8.0 max 5.5 true 8.0 max Active Memory Expansion Modeled Statistics: ----------------------- Modeled Expanded Memory Size : 8.00 GB Expansion True Memory Modeled Memory CPU Usage Factor Modeled Size Gain Estimate --------- -------------- ----------------- ----------- 1.21 6.75 GB 1.25 GB [ 19%] 0.00 1.31 6.25 GB 1.75 GB [ 28%] 0.20 1.41 5.75 GB 2.25 GB [ 39%] 0.35 1.51 5.50 GB 2.50 GB[ 45%] 0.58 1.61 5.00 GB 3.00 GB [ 60%] 1.46 Active Memory Expansion Recommendation: --------------------- The recommended AME configuration for this workload is to configure the LPAR with a memory size of 5.50 GB and to configure a memory expansion factor of 1.51. This will result in a memory expansion of 45% from the LPAR's current memory size. With this configuration, the estimated CPU usage due to Active Memory Expansion is approximately 0.58 physical processors, and the estimated overall peak CPU resource required for the LPAR is 3.72 physical processors. Sample output
  • 124. 110 IBM Power 720 and 740: Technical Overview and Introduction On the HMC menu describing the partition, select the Active Memory Expansion check box and enter true and max memory, as well as the memory expansion factor. To turn off expansion, you just have to unselect the check box. In both cases, a reboot of the partition is needed to activate the change. In addition, a one-time, 60-day trial of Active Memory Expansion is available to provide more exact memory expansion and CPU measurements. The trial can be requested using the Capacity on Demand web page: http://www.ibm.com/systems/power/hardware/cod/ Active Memory Expansion can be ordered with the initial order of the server or as an MES order. A software key is provided when the enablement feature is ordered that is applied to the server. A reboot is not required to enable the physical server. The key is specific to an individual server and is permanent. It cannot be moved to another server. This feature is ordered per server, independently of the number of partitions using memory expansion. It is possible to view if the Active Memory Expansion feature has been activated on a server from the HMC, as presented in Figure 3-6: Figure 3-6 Server capabilities listed from the HMC Note: In order to move an LPAR using Active Memory Expansion through Live Partition Mobility to another system, the target system must support AME. That means the target system must have AME activated through the software key. If the target system does not have AME activated, the mobility operation will fail during the pre-mobility check phase, and an appropriate error message will be displayed to the user.
  • 125. Chapter 3. Virtualization 111 For detailed information regarding Active Memory Expansion, you can download the document Active Memory Expansion: Overview and Usage Guide from: http://www.ibm.com/common/ssi/fcgi-bin/ssialias?infotype=SA&subtype=WH&appname=STG E_PO_PO_USEN&htmlfid=POW03037USEN&attachment=POW03037USEN.PDF 3.5 PowerVM PowerVM is the industry-leading virtualization solution for AIX, IBM i, and Linux environments on IBM POWER processor-based systems. PowerVM offers a secure virtualization environment, built on the advanced RAS features and leadership performance of the Power Systems platform. PowerVM features leading technologies such as Logical Partitioning, IBM Micro-Partitioning™, Power Hypervisor, Virtual I/O Server, PowerVM Lx86, PowerVM Live Partition Mobility, and PowerVM Active Memory Sharing. As with the previous Advanced Power Virtualization solution, PowerVM is a combination of hardware enablement and value-added software. The licensed features of each of the three editions of PowerVM are discussed in 3.5.1, “PowerVM editions” on page 111. 3.5.1 PowerVM editions This section provides information about the virtualization capabilities of the PowerVM. There are three versions of PowerVM, suited for various purposes: PowerVM Express Edition: PowerVM Express Edition is designed for customers looking for an introduction to more advanced virtualization features at a highly affordable price. PowerVM Standard Edition: PowerVM Standard Edition provides the most complete virtualization functionality for AIX, IBM i, and Linux operating systems in the industry. PowerVM Standard Edition is supported on all POWER processor-based servers and includes features designed to allow businesses to increase system utilization. PowerVM Enterprise Edition: PowerVM Enterprise Edition includes all the features of PowerVM Standard Edition plus two new industry-leading capabilities called Active Memory Sharing and Live Partition Mobility. Table 3-3 lists the codes of PowerVM editions that are available on the Power 720 and Power 740 servers. Table 3-3 Availability of PowerVM editions on the Power 720 and Power 740 PowerVM Editions Express Standard Enterprise IBM Power 720 #5225 #5227 #5228 IBM Power 740 #5225 #5227 #5228
  • 126. 112 IBM Power 720 and 740: Technical Overview and Introduction It is possible to upgrade from the Express Edition to the Standard or Enterprise Edition, and from Standard to Enterprise Editions. Table 3-4 outlines the functional elements of the three PowerVM editions. Table 3-4 PowerVM capabilities 3.5.2 Logical partitions Logical partitions (LPARs) and virtualization increase utilization of system resources and add a new level of configuration possibilities. This section provides details and configuration specifications for these topics. Dynamic logical partitioning Logical partitioning (LPAR) was introduced with the IBM POWER4™ processor-based product line and the IBM AIX Version 5.1 operating system. This technology offered the capability to divide a pSeries system into separate logical systems, allowing each LPAR to run an operating environment on dedicated attached devices, such as processors, memory, and I/O components. Later, dynamic logical partitioning increased the flexibility, allowing selected system resources, such as processors, memory, and I/O components, to be added and deleted from logical partitions while they are executing. IBM AIX Version 5.2, with all the necessary enhancements to enable dynamic LPARs, was introduced in 2002. The ability to reconfigure dynamic LPARs encourages system administrators to dynamically redefine all available system resources to reach the optimum capacity for each defined dynamic LPAR. Micro-Partitioning Micro-Partitioning technology allows you to allocate fractions of processors to a logical partition. This technology was introduced with POWER5 processor-based systems. A logical partition using fractions of processors is also known as a Shared Processor Partition or Micro-Partition. Micro-Partitions run over a set of processors called a Shared Processor Pool. Virtual processors are used to let the operating system manage the fractions of processing power assigned to the logical partition. From an operating system perspective, a virtual processor cannot be distinguished from a physical processor, unless the operating system has been enhanced to be made aware of the difference. Physical processors are abstracted into virtual processors that are available to partitions. The meaning of the term physical processor in this section is a processor core. For example, in a 2-core server there are two physical processors. PowerVM Editions Express Standard Enterprise Micro-partitions Yes Yes Yes Maximum LPARs 1 or 2 per server 10/core 10/core Management IVM IVM or HMC IVM or HMC Virtual IO Server Yes Yes Yes NPIV Yes Yes Yes Multiple Shared Processor Pool No Yes Yes Live Partition Mobility No No Yes Active Memory Sharing No No Yes
  • 127. Chapter 3. Virtualization 113 When defining a shared processor partition, various options have to be defined: The minimum, desired, and maximum processing units. Processing units are defined as processing power, or the fraction of time that the partition is dispatched on physical processors. Processing units define the capacity entitlement of the partition. The shared processor pool. Pick one from the list with the names of each configured shared processor pool. This list also displays the pool ID of each configured shared processor pool in parentheses. If the name of the desired shared processor pool is not available here, you must first configure the desired shared processor pool using the Shared Processor Pool Management window. Shared processor partitions use the default shared processor pool called DefaultPool by default. Whether the partition will be able or not to access extra processing power to “fill up” its virtual processors above its capacity entitlement. You select either to cap or uncap your partition. If there is spare processing power available in the shared processor pool or if other partitions are not using their entitlement, an uncapped partition can use additional processing units if its entitlement is not enough to satisfy its application processing demand. The weight (preference) in the case of an uncapped partition. The minimum, desired, and maximum number of virtual processors. The POWER Hypervisor calculates partitions’ processing power based on minimum, desired, and maximum values, processing mode, and also based on other active partitions’ requirements. The actual entitlement is never smaller than the processing units desired value but can exceed that value in the case of an uncapped partition and up to the number of virtual processors allocated. A partition can be defined with a processor capacity as small as 0.10 processing units. This represents 1/10th of a physical processor. Each physical processor can be shared by up to ten shared processor partitions, and the partition’s entitlement can be incremented fractionally by as little as 1/100th of the processor. The shared processor partitions are dispatched and time-sliced on the physical processors under control of the POWER Hypervisor. The shared processor partitions are created and managed by the HMC or Integrated Virtualization Management. The IBM Power 720 system can be configured with up to eight cores, and the IBM Power 740 up to 16 cores. These systems can support LPARs as follows: Up to 80 LPARs on a Power 720 Up to 160 LPARs on a Power 740 Here we provide additional information about virtual processors: A virtual processor can be either running (dispatched) on a physical processor or standby waiting for a physical processor to became available. Virtual processors do not introduce any additional abstraction level; they really are only a dispatch entity. When running on a physical processor, virtual processors run at the same speed as the physical processor. Each partition’s profile defines CPU entitlement that determines how much processing power any given partition must receive. The total sum of CPU entitlement of all partitions cannot exceed the number of available physical processors in a shared processor pool. The number of virtual processors can be changed dynamically through a dynamic LPAR operation. Important: The maximums stated are supported by the hardware, but the practical limits depend on the application workload demands.
  • 128. 114 IBM Power 720 and 740: Technical Overview and Introduction Processing Mode When you create a logical partition, you can assign entire processors for dedicated use, or you can assign partial processor units from a shared processor pool. This setting will define the processing mode of the logical partition. Figure 3-7 shows a diagram of the concepts discussed in this section. Figure 3-7 Logical partitioning concepts Dedicated mode In dedicated mode, physical processors are assigned as a whole to partitions. The simultaneous multithreading feature in the POWER7 processor core allows the core to execute instructions from two or four independent software threads simultaneously. To support this feature we use the concept of logical processors. The operating system (AIX, IBM i or Linux) sees one physical processor as two or four logical processors if the simultaneous multithreading feature is on. It can be turned off and on dynamically while the operating system is executing (for AIX, use the smtctl command). If simultaneous multithreading is off, then each physical processor is presented as one logical processor and thus only one thread. Shared dedicated mode On POWER7 processor technology based servers, you can configure dedicated partitions to become processor donors for idle processors they own, allowing for the donation of spare CPU cycles from dedicated processor partitions to a Shared Processor Pool. The dedicated partition maintains absolute priority for dedicated CPU cycles. Enabling this feature can help to increase system utilization, without compromising the computing power for critical workloads in a dedicated processor. Shared mode In shared mode, logical partitions use virtual processors to access fractions of physical processors. Shared partitions can define any number of virtual processors (the maximum number is 10 times the number of processing units assigned to the partition). From the POWER Hypervisor point of view, virtual processors represent dispatching objects. The POWER Hypervisor dispatches virtual processors to physical processors according to the Set of micro-partitions Dedicated processor partitions AIXV5.3 AIXV6.1 lp lplp lp lp lp AIXV6.1 1.5PrU AIXV5.3 0.5PrU lp lplp lplp lp vp vp vp Shared-Processor Pool 0 Set of micro-partitions AIXV6.1 1.5PrU Linux 0.5PrU lp lplp lplp lp vp vp vp Shared-Processor Pool 1 POWER Hypervisor Dedicated Processors Physical Shared-Processor Pool 8-core SMP System KEY: vp Virtual Processor lp Logical Processor PrU Processing Units
  • 129. Chapter 3. Virtualization 115 partition’s processing units entitlement. One Processing Unit represents one physical processor’s processing capacity. At the end of the POWER Hypervisor’s dispatch cycle (10 ms), all partitions must receive total CPU time equal to their processing units entitlement. The logical processors are defined on top of virtual processors. So, even with a virtual processor, the concept of a logical processor exists and the number of logical processors depends on whether the simultaneous multithreading is turned on or off. 3.5.3 Multiple Shared-Processor Pools Multiple Shared-Processor Pools (MSPPs) is a capability supported on POWER7 and POWER6 processor-based servers. This capability allows a system administrator to create a set of micro-partitions with the purpose of controlling the processor capacity that can be consumed from the physical shared-processor pool. To implement MSPPs, there is a set of underlying techniques and technologies. An overview of the architecture of Multiple Shared-Processor Pools can be seen in Figure 3-8. Figure 3-8 Overview of the architecture of Multiple Shared-Processor Pools Micro-partitions are created and then identified as members of either the default Shared-Processor Pool0 or a user-defined Shared-Processor Pooln. The virtual processors that exist within the set of micro-partitions are monitored by the POWER Hypervisor and processor capacity is managed according to user-defined attributes. If the Power Systems server is under heavy load, each micro-partition within a Shared-Processor Pool is guaranteed its processor entitlement plus any capacity that it can be allocated from the Reserved Pool Capacity if the micro-partition is uncapped. Physical Shared-Processor Pool Shared-Processor Pool0 Set micro-partitions AIX V6.1 EC 0.8 vp2 Linux EC 0.5 vp3 vp4 AIX V5.3 EC 1.6 vp0 vp1 Shared-Processor Pool1 Set micro-partitions AIX V6.1 EC 1.6 vp5 vp6 vp7 AIX V6.1 EC 0.8 vp8 Linux EC 0.5 vp9 vp10 POWER Hypervisor p0 p7p4 p5 p6p2 p3p1 KEY: EC Entitled Capacity p Physical Processor vp Virtual Processor SPPn Shared-Processor Pooln Unused capacity in SPP1 is redistributed to uncapped micro partitions with SPP1 Unused capacity in SPP0 is redistributed to uncapped micro partitions with SPP0
  • 130. 116 IBM Power 720 and 740: Technical Overview and Introduction If certain micro-partitions in a Shared-Processor Pool do not use their capacity entitlement, the unused capacity is ceded and other uncapped micro-partitions within the same Shared-Processor Pool are allocated the additional capacity according to their uncapped weighting. In this way, the Entitled Pool Capacity of a Shared-Processor Pool is distributed to the set of micro-partitions within that Shared-Processor Pool. All Power Systems servers that support the Multiple Shared-Processor Pools capability will have a minimum of one (the default) Shared-Processor Pool and up to a maximum of 64 Shared-Processor Pools. Default Shared-Processor Pool (SPP0) On any Power Systems server supporting Multiple Shared-Processor Pools, a default Shared-Processor Pool is always automatically defined. The default Shared-Processor Pool has a pool identifier of zero (SPP-ID = 0) and can also be referred to as SPP0. The default Shared-Processor Pool has the same attributes as a user-defined Shared-Processor Pool except that these attributes are not directly under the control of the system administrator; they have fixed values (Table 3-5). Table 3-5 Attribute values for the default Shared-Processor Pool (SPP0) Creating Multiple Shared-Processor Pools The default Shared-Processor Pool (SPP0) is automatically activated by the system and is always present. All other Shared-Processor Pools exist, but by default, are inactive. By changing the Maximum Pool Capacity of a Shared-Processor Pool to a value greater than zero, it becomes active and can accept micro-partitions (either transferred from SPP0 or newly created). Levels of processor capacity resolution There are two levels of processor capacity resolution implemented by the POWER Hypervisor and Multiple Shared-Processor Pools: Level0 The first level, Level0, is the resolution of capacity within the same Shared-Processor Pool. Unused processor cycles from within a Shared-Processor Pool are harvested and then redistributed to any eligible micro-partition within the same Shared-Processor Pool. Level1 When all Level0 capacity has been resolved within the Multiple Shared-Processor Pools, the POWER Hypervisor harvests unused processor cycles and redistributes them to eligible micro-partitions regardless of the Multiple Shared-Processor Pools structure. This is the second level of processor capacity resolution. SPP0 attribute Value Shared-Processor Pool ID 0 Maximum Pool Capacity The value is equal to the capacity in the physical shared-processor pool. Reserved Pool Capacity 0 Entitled Pool Capacity Sum (total) of the entitled capacities of the micro-partitions in the default Shared-Processor Pool.
  • 131. Chapter 3. Virtualization 117 You can see the two levels of unused capacity redistribution implemented by the POWER Hypervisor in Figure 3-9. Figure 3-9 The two levels of unused capacity redistribution Capacity allocation above the Entitled Pool Capacity (Level1) The POWER Hypervisor initially manages the Entitled Pool Capacity at the Shared-Processor Pool level. This is where unused processor capacity within a Shared-Processor Pool is harvested and then redistributed to uncapped micro-partitions within the same Shared-Processor Pool. This level of processor capacity management is sometimes referred to as Level0 capacity resolution. At a higher level, the POWER Hypervisor harvests unused processor capacity from the Multiple Shared-Processor Pools that do not consume all of their Entitled Pool Capacity. If a particular Shared-Processor Pool is heavily loaded and some of the uncapped micro-partitions within it require additional processor capacity (above the Entitled Pool Capacity) then the POWER Hypervisor redistributes some of the extra capacity to the uncapped micro-partitions. This level of processor capacity management is sometimes referred to as Level1 capacity resolution. To redistribute unused processor capacity to uncapped micro-partitions in Multiple Shared-Processor Pools above the Entitled Pool Capacity, the POWER Hypervisor uses a higher level of redistribution, Level1. POWER Hypervisor Physical Shared-Processor Pool SPP0 Micro-partition0 Micro-partition1 Micro-partition2 Micro-partition3 SPP1 SPP2 SPPn Micro-partitionn Level1 Capacity Resolution SPP0 Capacity Resolution SPP1 Capacity Resolution SPP2Capacity Resolution SPP3Capacity Resolution p0 p1 p2 p3 p4 p5 Level0 Capacity Resolution Resolution of the Entitled Pool Capacity within the same Shared-Processor Pool Level0 Capacity Resolution Level1 Capacity Resolution POWER Hypervisor harvests unused processor capacity from Shared-Processor Pools and redistributes it across all uncapped micro-partitions regardless of the Shared-Processor Pool structure
  • 132. 118 IBM Power 720 and 740: Technical Overview and Introduction Where there is unused processor capacity in underutilized Shared-Processor Pools, the micro-partitions within the Shared-Processor Pools cede the capacity to the POWER Hypervisor. In busy Shared-Processor Pools where the micro-partitions have used all of the Entitled Pool Capacity, the POWER Hypervisor will allocate additional cycles to micro-partitions under the following circumstances: The Maximum Pool Capacity of the Shared-Processor Pool hosting the micro-partition has not been met. (and) The micro-partition is uncapped. (and) The micro-partition has enough virtual-processors to take advantage of the additional capacity. Under such circumstances, the POWER Hypervisor allocates additional processor capacity to micro-partitions on the basis of their uncapped weights independent of the Shared-Processor Pool hosting the micro-partitions. This can be referred to as Level1 capacity resolution. Consequently, when allocating additional processor capacity in excess of the Entitled Pool Capacity of the Shared-Processor Pools, the POWER Hypervisor takes the uncapped weights of all micro-partitions in the system into account, regardless of the Multiple Shared-Processor Pools structure. Dynamic adjustment of Maximum Pool Capacity The Maximum Pool Capacity of a Shared-Processor Pool, other than the default Shared-Processor Pool0, can be adjusted dynamically from the HMC using either the graphical or CLI interface. Dynamic adjustment of Reserve Pool Capacity The Reserved Pool Capacity of a Shared-Processor Pool, other than the default Shared-Processor Pool0, can be adjusted dynamically from the HMC using either the graphical or CLI interface. Dynamic movement between Shared-Processor Pools A micro-partition can be moved dynamically from one Shared-Processor Pool to another using the HMC using either the graphical or CLI interface. Because the Entitled Pool Capacity is partly made up of the sum of the entitled capacities of the micro-partitions, removing a micro-partition from a Shared-Processor Pool will reduce the Entitled Pool Capacity for that Shared-Processor Pool. Similarly, the Entitled Pool Capacity of the Shared-Processor Pool that the micro-partition joins will increase. Deleting a Shared-Processor Pool Shared-Processor Pools cannot be deleted from the system, but they can be deactivated by setting the Maximum Pool Capacity and the Reserved Pool Capacity to zero. By doing so, the Shared-Processor Pool will still exist but will not be active. You can use the HMC interface to deactivate a Shared-Processor Pool. Be aware that a Shared-Processor Pool cannot be deactivated unless all micro-partitions hosted by the Shared-Processor Pool have been removed. Important: For Level1 capacity resolution, when allocating additional processor capacity in excess of the Entitled Pool Capacity of the Shared-Processor Pool, the POWER Hypervisor takes into account the uncapped weights of all micro-partitions in the system, regardless of the Multiple Shared-Processor Pool structure.
  • 133. Chapter 3. Virtualization 119 Live Partition Mobility and Multiple Shared-Processor Pools A micro-partition can leave a Shared-Processor Pool due to PowerVM Live Partition Mobility. Similarly, a micro-partition can join a Shared-Processor Pool in the same way. When performing PowerVM Live Partition Mobility, you are given the opportunity to designate a destination Shared-Processor Pool on the target server to receive and host the migrating micro-partition. Because several simultaneous micro-partition migrations are supported by PowerVM Live Partition Mobility, it is conceivable to migrate the entire Shared-Processor Pool from one server to another. 3.5.4 Virtual I/O Server The Virtual I/O Server is part of all PowerVM Editions. It is a special purpose partition that allows the sharing of physical resources between logical partitions to allow more efficient utilization (for example consolidation). In this case the Virtual I/O Server owns the physical resources (SCSI, Fibre Channel, network adapters, and optical devices) and allows client partitions to share access to them, thus minimizing the number of physical adapters in the system. The Virtual I/O Server eliminates the requirement that every partition owns a dedicated network adapter, disk adapter, and disk drive. The Virtual I/O Server supports OpenSSH for secure remote logins. It also provides a firewall for limiting access by ports, network services and IP addresses. Figure 3-10 shows an overview of a Virtual I/O Server configuration. Figure 3-10 Architectural view of the Virtual I/O Server Because the Virtual I/O server is an operating system-based appliance server, redundancy for physical devices attached to the Virtual I/O Server can be provided by using capabilities such as Multipath I/O and IEEE 802.3ad Link Aggregation. Installation of the Virtual I/O Server partition is performed from a special system backup DVD that is provided to clients that order any PowerVM edition. This dedicated software is only for the Virtual I/O Server (and IVM in case it is used) and is only supported in special Virtual I/O Server partitions. Three major virtual devices are supported by the Virtual I/O Server: a Shared Ethernet Adapter, Virtual SCSI and Virtual Fibre Channel adapter. The Virtual Fibre Channel adapter is used with the NPIV feature, described in 3.5.8, “NPIV” on page 126. Virtual I/O Server Virtual I/O Client 1Hypervisor Virtual I/O Client 2 Physical Ethernet Adapter Shared Ethernet Adapter External Network Physical Disk Adapter Physical Disk Physical Disk Virtual SCSI Adapter Virtual Ethernet Adapter Virtual Ethernet Adapter Virtual SCSI Adapter Virtual SCSI Adapter Virtual Ethernet Adapter
  • 134. 120 IBM Power 720 and 740: Technical Overview and Introduction Shared Ethernet Adapter A Shared Ethernet Adapter (SEA) can be used to connect a physical Ethernet network to a virtual Ethernet network. The Shared Ethernet Adapter provides this access by connecting the internal Hypervisor VLANs with the VLANs on the external switches. Because the Shared Ethernet Adapter processes packets at layer 2, the original MAC address and VLAN tags of the packet are visible to other systems on the physical network. IEEE 802.1 VLAN tagging is supported. The Shared Ethernet Adapter also provides the ability for several client partitions to share one physical adapter. Using an SEA, you can connect internal and external VLANs using a physical adapter. The Shared Ethernet Adapter service can only be hosted in the Virtual I/O Server, not in a general purpose AIX, IBM i, or Linux partition, and acts as a layer-2 network bridge to securely transport network traffic between virtual Ethernet networks (internal) and one or more (EtherChannel) physical network adapters (external). These virtual Ethernet network adapters are defined by the POWER Hypervisor on the Virtual I/O Server Figure 3-11 shows a configuration example of an SEA with one physical and two virtual Ethernet adapters. An SEA can include up to 16 virtual Ethernet adapters on the Virtual I/O Server that share the same physical access. Figure 3-11 Architectural view of a Shared Ethernet Adapter Tip: A Linux partition can provide bridging function as well, by using the brctl command. Ethernet Switch Hypervisor VIOS Default Client 1 Client 2 Client 3 VID=2 (PVID=99) PVID=1 PVID=2 VLAN=2 VLAN=1 (PVID=1)VLAN=2 PVID=1 PVID=1 External Network en3 (if.) ent3 (sea) ent1 (virt.) ent2 (virt.) ent0 (phy.) en0 (if.) ent0 (virt.) en0 (if.) ent0 (virt.) en0 (if.) ent0 (virt.)
  • 135. Chapter 3. Virtualization 121 A single SEA setup can have up to 16 Virtual Ethernet trunk adapters, and each virtual Ethernet trunk adapter can support up to 20 VLAN networks. Therefore, it is possible for a single physical Ethernet to be shared between 320 internal VLANs. The number of shared Ethernet adapters that can be set up in a Virtual I/O server partition is limited only by the resource availability, because there are no configuration limits. Unicast, broadcast, and multicast is supported, so protocols that rely on broadcast or multicast, such as Address Resolution Protocol (ARP), Dynamic Host Configuration Protocol (DHCP), Boot Protocol (BOOTP), and Neighbor Discovery Protocol (NDP) can work across an SEA. Virtual SCSI Virtual SCSI is used to refer to a virtualized implementation of the SCSI protocol. Virtual SCSI is based on a client/server relationship. The Virtual I/O Server logical partition owns the physical resources and acts as server or, in SCSI terms, target device. The client logical partitions access the virtual SCSI backing storage devices provided by the Virtual I/O Server as clients. The virtual I/O adapters (a virtual SCSI server adapter and a virtual SCSI client adapter) are configured using an HMC or through the Integrated Virtualization Manager. The virtual SCSI server (target) adapter is responsible for executing any SCSI commands it receives. It is owned by the Virtual I/O Server partition. The virtual SCSI client adapter allows a client partition to access physical SCSI and SAN attached devices and LUNs that are assigned to the client partition. The provisioning of virtual disk resources is provided by the Virtual I/O Server. Physical disks presented to the Virtual/O Server can be exported and assigned to a client partition in a number of ways: The entire disk is presented to the client partition. The disk is divided into several logical volumes, which can be presented to a single client or multiple clients. As of Virtual I/O Server 1.5 or later, files can be created on these disks and file backed storage devices can be created. The logical volumes or files can be assigned to various partitions. Therefore, virtual SCSI enables sharing of adapters as well as disk devices. Figure 3-12 on page 122 shows an example where one physical disk is divided into two logical volumes by the Virtual I/O Server. Each of the two client partitions is assigned one logical volume, which is then accessed through a virtual I/O adapter (VSCSI Client Adapter). Inside the partition, the disk is seen as a normal hdisk. Note: A Shared Ethernet Adapter does not need to have an IP address configured to be able to perform the Ethernet bridging functionality. It is very convenient to configure IP on the Virtual I/O Server, because the Virtual I/O Server can then be reached by TCP/IP, for example, to perform dynamic LPAR operations or to enable remote login. These operations can be done either by configuring an IP address directly on the SEA device, or on an additional virtual Ethernet adapter in the Virtual I/O Server, thus leaving the SEA without the IP address, and allowing for maintenance on the SEA without losing IP connectivity in case SEA failover is configured.
  • 136. 122 IBM Power 720 and 740: Technical Overview and Introduction Figure 3-12 Architectural view of virtual SCSI At the time of writing, virtual SCSI supports Fibre Channel, parallel SCSI, iSCSI, SAS, SCSI RAID devices and optical devices, including DVD-RAM and DVD-ROM. Other protocols such as SSA and tape devices are not supported. For more information about the specific storage devices supported for Virtual I/O Server, see: http://www14.software.ibm.com/webapp/set2/sas/f/vios/documentation/datasheet.html Virtual I/O Server functions Virtual I/O Server includes a number of features, including monitoring solutions: Support for Live Partition Mobility on POWER6 and POWER7 processor-based systems with the PowerVM Enterprise Edition. More information about Live Partition Mobility can be found in 3.5.6, “PowerVM Live Partition Mobility” on page 123. Support for virtual SCSI devices backed by a file. These are then accessed as standard SCSI-compliant LUNs. Support for virtual Fibre Channel devices used with the NPIV feature. Virtual I/O Server Expansion Pack with additional security functions such as Kerberos (Network Authentication Service for users and Client and Server Applications), SNMP v3 (Simple Network Management Protocol) and LDAP (Lightweight Directory Access Protocol client functionality). System Planning Tool (SPT) and Workload Estimator are designed to ease the deployment of a virtualized infrastructure. More information about the System Planning Tool is provided in 3.6, “System Planning Tool” on page 128. IBM Systems Director and a number of pre-installed IBM Tivoli® agents are included, such as Tivoli Identity Manager (TIM), in order to allow easy integration into an existing Tivoli Systems Management infrastructure, and Tivoli Application Dependency Discovery Manager (ADDM), which creates and maintains automatically application infrastructure maps, including dependencies, change histories, and deep configuration values. vSCSI eRAS is also available. Client Partition 1I/O Server Partition LVM Client Partition 2 Logical Volume 1 Logical Volume 2 Hdisk Hdisk POWER Hypervisor Physical Disk (SCSI, FC) Physical Adapter vSCSI Server Adapter vSCSI Server Adapter vSCSI Client Adapter vSCSI Client Adapter
  • 137. Chapter 3. Virtualization 123 Additional Command Line Interface (CLI) statistics in svmon, vmstat, fcstat, and topas Monitoring solutions to help manage and monitor the Virtual I/O Server and shared resources. New commands and views provide additional metrics for memory, paging, processes, Fibre Channel HBA statistics, and virtualization. For more information on the Virtual I/O Server and its implementation, see PowerVM Virtualization on IBM System p: Introduction and Configuration Fourth Edition, SG24-7940. 3.5.5 PowerVM Lx86 PowerVM Lx86 supports the installation and running of most 32-bit x86 Linux applications on any POWER5, POWER5+, POWER6, POWER6+, and POWER7 processor-based server, or IBM Power Architecture technology-based blade servers. PowerVM Lx86 creates a virtual x86 environment, within which the Linux on Intel® applications can run. Currently, a virtual PowerVM Lx86 environment supports SUSE Linux or Red Hat Linux x86 distributions. The translator and the virtual environment run strictly within user space. No modifications to the POWER kernel are required. PowerVM Lx86 does not run the x86 kernel on the POWER system and is not a virtual machine. Instead, x86 applications are encapsulated so that the operating environment appears to be Linux on x86, even though the underlying system is a Linux on POWER system. PowerVM Lx86 release 1.4 supports all POWER7 processors-based servers. For more information about PowerVM Lx86, see the following website: http://www14.software.ibm.com/webapp/set2/sas/f/lx86/related/home.html 3.5.6 PowerVM Live Partition Mobility PowerVM Live Partition Mobility allows you to move a running logical partition, including its operating system and running applications, from one system to another without any shutdown or without disrupting the operation of that logical partition. Inactive partition mobility allows you to move a powered off logical partition from one system to another. Partition mobility provides systems management flexibility and improves system availability: Avoid planned outages for hardware or firmware maintenance by moving logical partitions to another server and then performing the maintenance. Live Partition Mobility can help lead to zero downtime maintenance because you can use it to work around scheduled maintenance activities. Avoid downtime for a server upgrade by moving logical partitions to another server and then performing the upgrade. This allows your end users to continue their work without disruption. Perform preventive failure management: If a server indicates a potential failure, you can move its logical partitions to another server before the failure occurs. Partition mobility can help avoid unplanned downtime. Optimize server workloads: – You can consolidate workloads running on several small, under-utilized servers onto a single large server. Note: RHEL5 only supports POWER7 processor-based servers in POWER6 Compatibility Mode. Customers will need to use SLES11 to take full advantage of the POWER7 technology.
  • 138. 124 IBM Power 720 and 740: Technical Overview and Introduction – Deconsolidation: You can move workloads from server to server to optimize resource use and workload performance within your computing environment. With active partition mobility, you can manage workloads with minimal downtime. Use Live Partition Mobility for a migration from POWER6 to POWER7 processor-based servers without any downtime of your applications. Mobile partition’s operating system requirements The operating system running in the mobile partition must be AIX or Linux. The Virtual I/O Server partition itself cannot be migrated. All versions of AIX and Linux supported on the IBM POWER7 processor-based servers also support partition mobility. Source and destination system requirements The source partition must be one that only has virtual devices. If there are any physical devices in its allocation, they must be removed before the validation or migration is initiated. An NPIV device is considered virtual and is compatible with partition migration. The POWER Hypervisor must support the Partition Mobility functionality also called migration process. POWER6 and POWER7 processor-based Hypervisors have this capability and firmware must be at firmware level eFW3.2 or later. All POWER7 processor-based hypervisors support Partition Mobility. Source and destination systems can have various firmware levels, but they must be compatible with each other. It is possible to migrate partitions back and forth between POWER6 and POWER7 processor-based servers. Partition Mobility leverages the POWER6 Compatibility Modes provided by POWER7 processor-based servers. On the POWER7 processor technology based server, the migrated partition is then executing in POWER6 or POWER6+ Compatibility Mode. If you want to move an active logical partition from a POWER6 processor-based server to a POWER7 processor-based server so that the logical partition can take advantage of the additional capabilities available with the POWER7 processor, you can perform these steps: 1. You set the percolating preferred processor compatibility mode to the default mode. When you activate the logical partition on the POWER6 processor-based server, it runs in the POWER6 mode. 2. You move the logical partition to the POWER7 processor-based server. Both the current and preferred modes remain unchanged for the logical partition until you restart the logical partition. 3. You restart the logical partition on the POWER7 processor-based server. The hypervisor evaluates the configuration. Because the preferred mode is set to default and the logical partition now runs on a POWER7 processor-based server, the highest mode available is the POWER7 mode. The POWER hypervisor determines that the most fully featured mode supported by the operating environment installed in the logical partition is the POWER7 mode and changes the current mode of the logical partition to the POWER7 mode. At this point, the current processor compatibility mode of the logical partition is the POWER7 mode and the logical partition runs on the POWER7 processor-based server. Tip: For an exhaustive presentation of the supported migrations, see the “Migration combinations of processor compatibility modes for active Partition Mobility” web page: http://publib.boulder.ibm.com/infocenter/powersys/v3r1m5/topic/p7hc3/iphc3pcmco mbosact.htm
  • 139. Chapter 3. Virtualization 125 The Virtual I/O Server on the source system provides access to the client resources and must be identified as a Mover Service Partition (MSP). The Virtual Asynchronous Services Interface (VASI) device allows the mover service partition to communicate with the POWER hypervisor; it is created and managed automatically by the HMC and will be configured on both the source and destination Virtual I/O Servers designated as the mover service partitions for the mobile partition to participate in active mobility. Other requirements include a similar Time of Day on each server, systems cannot be running on battery power, shared storage (turn off SCSI reservation at any external hdisk using reserve_policy=no_reserve), and all logical partitions must be on the same open network with RMC established to the HMC. The HMC is used to configure, validate, and orchestrate. You will use the HMC to configure the Virtual I/O Server as an MSP and to configure the VASI device. An HMC wizard validates your configuration and identifies issues that will cause the migration to fail. During the migration, the HMC controls all phases of the process. Improved Live Partition Mobility benefits The possibility to move partitions between POWER6 and POWER7 processor-based servers greatly facilitates the deployment of POWER7 processor technology based servers: Installation of the new server can be performed while the application is executing on the POWER6 server. When the POWER7 processor technology based server is ready, the application can be migrated to its new hosting server without application down time. When adding POWER7 processor technology based servers to a POWER6 environment, you get the additional flexibility to perform workload balancing across the whole set of POWER6 and POWER7 processor technology based servers. When performing server maintenance, you get the additional flexibility to utilize POWER6 Servers for hosting applications usually hosted on POWER7 processor technology based servers, and the opposite situation, allowing you to perform this maintenance with no application planned down time. For more information about Live Partition Mobility and how to implement it, see IBM PowerVM Live Partition Mobility, SG24-7460. 3.5.7 Active Memory Sharing Active Memory Sharing is an IBM PowerVM advanced memory virtualization technology that provides system memory virtualization capabilities to IBM Power Systems, allowing multiple partitions to share a common pool of physical memory. Active Memory Sharing is only available with PowerVM Enterprise edition. The physical memory of a IBM Power System server can be assigned to multiple partitions either in a dedicated mode or a shared mode. The system administrator has the capability to assign part of the physical memory to a partition and other physical memory to a pool that is shared by other partitions. A single partition can have either dedicated or shared memory. Note: A new Trial PowerVM Live Partition Mobility feature (#ELPM) is available on multiple POWER7 machine type models, which will enable clients to upgrade from PowerVM Standard Edition to PowerVM Enterprise Edition at no charge for 60 days. At the conclusion of the trial period clients can place an upgrade order for permanent PowerVM Enterprise Edition to maintain continuity. At the end of the trial period (60 days), the client's system will automatically return to PowerVM Standard Edition.
  • 140. 126 IBM Power 720 and 740: Technical Overview and Introduction With a pure dedicated memory model, it is system administrator’s task to optimize available memory distribution among partitions. When a partition suffers degradation due to memory constraints and other partitions have unused memory, the administrator can manually react by issuing a dynamic memory reconfiguration. With a shared memory model it is the system that automatically decides the optimal distribution of the physical memory to partitions and adjusts the memory assignment based on partition load. The administrator reserves physical memory for the shared memory pool, assigns partitions to the pool, and provides access limits to the pool. Active Memory Sharing can be exploited to increase memory utilization on the system either by decreasing the global memory requirement or by allowing the creation of additional partitions on an existing system. Active Memory Sharing can be used in parallel with Active Memory Expansion on a system running a mixed workload of several operating systems. For example, AIX partitions can take advantage of Active Memory Expansion while other operating systems take advantage of Active Memory Sharing. For additional information regarding Active Memory Sharing, see PowerVM Virtualization Active Memory Sharing, REDP-4470. 3.5.8 NPIV N_Port ID virtualization (NPIV) is a technology that allows multiple logical partitions to access independent physical storage through the same physical Fibre Channel adapter. This adapter is attached to a Virtual I/O Server partition, which acts only as a pass-through managing the data transfer through the POWER Hypervisor. Each partition using NPIV is identified by a pair of unique worldwide port names, enabling you to connect each partition to independent physical storage on a SAN. Unlike virtual SCSI, only the client partitions see the disk. For additional information about NPIV, see the following Redbooks publications: IBM PowerVM Virtualization Managing and Monitoring, SG24-7590 PowerVM Migration from Physical to Virtual Storage, SG24-7825 NPIV is supported with PowerVM Express, Standard, and Enterprise Editions, on all POWER7 processor-based servers and IBM Power Architecture technology-based blade servers, hosted by VIOS 2.1.3 or later and LPARS using AIX 5.3, AIX 6.1, IBM i 6.1.1, SLES 11, and RHEL 5.4, or later. 3.5.9 Operating System support for PowerVM Table 3-6 summarizes the PowerVM features supported by the operating systems compatible with the POWER7 processor-based servers. Table 3-6 PowerVM features supported by AIX, IBM i and Linux Feature AIX 5.3 AIX 6.1 AIX 7.1 IBM i 6.1.1 IBM i 7.1 RHEL 5.5 SLES 10 SP3 SLES 11 SP1 Simultaneous Multi-Threading (SMT) Yes1 Yes2 Yes Yes5 Yes Yes1 Yes1 Yes DLPAR I/O adapter add/remove Yes Yes Yes Yes Yes Yes Yes Yes
  • 141. Chapter 3. Virtualization 127 1 Only supports two threads. 2 AIX 6.1 up to TL4 SP2 only supports two threads, and supports four threads as of TL4 SP3. 3 Available on selected models. 4 On AIX 6.1 with TL4 SP2 and later. 5 IBM i 6.1.1 and up support SMT4. 3.5.10 POWER7-specific Linux programming support The IBM Linux Technology Center (LTC) contributes to the development of Linux by providing support for IBM hardware in Linux distributions. In particular, the LTC makes tools and code available to the Linux communities to take advantage of the POWER7 technology, and develop POWER7 optimized software. Table 3-7 summarizes the support of specific programming features for various versions of Linux. Table 3-7 Linux support for POWER7 features DLPAR processor add/remove Yes Yes Yes Yes Yes Yes Yes Yes DLPAR memory add Yes Yes Yes Yes Yes Yes Yes Yes DLPAR memory remove Yes Yes Yes Yes Yes No No Yes Capacity on Demand 3 Yes Yes Yes Yes Yes Yes Yes Yes Micro-Partitioning Yes Yes Yes Yes Yes Yes Yes Yes Shared Dedicated Capacity Yes Yes Yes Yes Yes Yes Yes Yes Multiple Shared Processor Pools Yes Yes Yes Yes Yes Yes Yes Yes Virtual I/O Server Yes Yes Yes Yes Yes Yes Yes Yes IVM Yes Yes Yes Yes Yes Yes Yes Yes Virtual SCSI Yes Yes Yes Yes Yes Yes Yes Yes Virtual Ethernet Yes Yes Yes Yes Yes Yes Yes Yes NPIV Yes Yes Yes Yes Yes Yes No Yes Live Partition Mobility Yes Yes Yes No No Yes Yes Yes Workload Partitions No Yes Yes No No No No No Active Memory Sharing Yes Yes Yes Yes Yes No No Yes Active Memory Expansion No Yes4 Yes No No No No No Feature AIX 5.3 AIX 6.1 AIX 7.1 IBM i 6.1.1 IBM i 7.1 RHEL 5.5 SLES 10 SP3 SLES 11 SP1 Features Linux Releases Comments SLES 10 SP3 SLES 11 SP1 RHEL 5.5 POWER6 compatibility mode Yes Yes Yes
  • 142. 128 IBM Power 720 and 740: Technical Overview and Introduction For information regarding Advanced Toolchain, see the “How to use Advance Toolchain for Linux” website: http://www.ibm.com/developerworks/wikis/display/hpccentral/How+to+use+Advance+Tool chain+for+Linux+on+POWER You can also see the University of Illinois Linux on Power Open Source Repository: http://ppclinux.ncsa.illinois.edu ftp://linuxpatch.ncsa.uiuc.edu/toolchain/at/at05/suse/SLES_11/release_notes.at05-2 .1-0.html ftp://linuxpatch.ncsa.uiuc.edu/toolchain/at/at05/redhat/RHEL5/release_notes.at05-2 .1-0.html 3.6 System Planning Tool The IBM System Planning Tool (SPT) helps you design a system or systems to be partitioned with logical partitions. You can also plan for and design non-partitioned systems using the SPT. The resulting output of your design is called a system plan, which is stored in a .sysplan file. This file can contain plans for a single system or multiple systems. The .sysplan file can be used: To create reports As input to the IBM configuration tool (e-Config) To create and deploy partitions on your systems automatically System plans generated by the SPT can be deployed on the system by the Hardware Management Console (HMC) or the Integrated Virtualization Manager (IVM). POWER7 mode No Yes No Strong Access Ordering No Yes No To improve Lx86 performance Scale to 256 cores / 1024 threads No Yes No Base OS support available. 4-way SMT No Yes No VSX Support No Yes No Distro toolchain mcpu/mtune=p7 No Yes No Advance Toolchain Support Yes; execution restricted to POWER6 instructions Yes Yes; execution restricted to POWER6 instructions Alternative IBM gnu Toolchain 64k base page size No Yes Yes Tickless idle No Yes No Improved energy utilization and virtualization of partially to fully idle partitions. Features Linux Releases Comments SLES 10 SP3 SLES 11 SP1 RHEL 5.5
  • 143. Chapter 3. Virtualization 129 You can create an entirely new system configuration, or you can create a system configuration based upon any of the following considerations: Performance data from an existing system that the new system is to replace Performance estimates anticipating future workloads that you must support Sample systems that you can customize to fit your needs Integration between the SPT and both the Workload Estimator (WLE) and IBM Performance Management (PM) allows you to create a system that is based upon performance and capacity data from an existing system or one based on new workloads that you specify. Before you order a system, you can use the SPT to determine what you have to order to support your workload. You can also use the SPT to determine how you can partition a system that you already have. Use the IBM System Planning Tool to estimate POWER Hypervisor requirements and determine the memory resources required for all partitioned and non-partitioned servers. Figure 3-13 shows the estimated Hypervisor memory requirements based on sample partition requirements. Note: Ask your IBM representative or Business Partner representative to use the Customer Specified Placement manufacturing option if you want to automatically deploy your partitioning environment on a new machine. SPT looks for the resource allocation to be the same as that specified on your .sysplan file.
  • 144. 130 IBM Power 720 and 740: Technical Overview and Introduction Figure 3-13 IBM System Planning Tool window showing Hypervisor memory requirements For the SPT and its supporting documentation, see the IBM System Planning Tool site at: http://www.ibm.com/systems/support/tools/systemplanningtool
  • 145. © Copyright IBM Corp. 2010. All rights reserved. 131 Chapter 4. Continuous availability and manageability This chapter provides information about IBM reliability, availability, and serviceability (RAS) design and features. This set of technologies, implemented on IBM Power Systems servers, provides the possibility to improve your architecture’s total cost of ownership (TCO) by reducing unplanned down time. The elements of RAS can be described as follows: Reliability: Indicates how infrequently a defect or fault in a server manifests itself. Availability: Indicates how infrequently the functionality of a system or application is impacted by a fault or defect. Serviceability: Indicates how well faults and their effects are communicated to users and services and how efficiently and nondisruptively the faults are repaired. Each successive generation of IBM servers is designed to be more reliable than the previous server family. POWER7 processor-based servers have new features to support new levels of virtualization, help ease administrative burden and increase system utilization. Reliability starts with components, devices, and subsystems designed to be fault-tolerant. POWER7 uses lower voltage technology improving reliability with stacked latches to reduce soft error susceptibility. During the design and development process, subsystems go through rigorous verification and integration testing processes. During system manufacturing, systems go through a thorough testing process to help ensure high product quality levels. The processor and memory subsystem contain a number of features designed to avoid or correct environmentally induced, single-bit, intermittent failures as well as handle solid faults in components, including selective redundancy to tolerate certain faults without requiring an outage or parts replacement. 4
  • 146. 132 IBM Power 720 and 740: Technical Overview and Introduction 4.1 Reliability Highly reliable systems are built with highly reliable components. On IBM POWER processor-based systems, this basic principle is expanded upon with a clear design for reliability architecture and methodology. A concentrated, systematic, architecture-based approach is designed to improve overall system reliability with each successive generation of system offerings. 4.1.1 Designed for reliability Systems designed with fewer components and interconnects have fewer opportunities to fail. Simple design choices such as integrating processor cores on a single POWER chip can dramatically reduce the opportunity for system failures. In this case, an 8-core server can include one-fourth as many processor chips (and chip socket interfaces) as with a double CPU-per-processor design. Not only does this case reduce the total number of system components, it reduces the total amount of heat generated in the design, resulting in an additional reduction in required power and cooling components. POWER7 processor-based servers also integrate L3 cache into the processor chip for a higher integration of parts. Parts selection also plays a critical role in overall system reliability. IBM uses three grades of components; grade 3 defined as industry standard (off-the-shelf). As shown in Figure 4-1, using stringent design criteria and an extensive testing program, the IBM manufacturing team can produce grade 1 components that are expected to be 10 times more reliable than industry standard. Engineers select grade 1 parts for the most critical system components. Newly introduced organic packaging technologies, rated grade 5, achieve the same reliability as grade 1 parts. Figure 4-1 Component failure rates Component failure rates 0 0.2 0.4 0.6 0.8 1 Grade 3 Grade 1 Grade 5
  • 147. Chapter 4. Continuous availability and manageability 133 4.1.2 Placement of components Packaging is designed to deliver both high performance and high reliability. For example, the reliability of electronic components is directly related to their thermal environment, that is, large decreases in component reliability are directly correlated with relatively small increases in temperature; POWER processor-based systems are carefully packaged to ensure adequate cooling. Critical system components such as the POWER7 processor chips are positioned on printed circuit cards so they receive fresh air during operation. In addition, POWER processor-based systems are built with redundant, variable-speed fans that can automatically increase output to compensate for increased heat in the central electronic complex. 4.1.3 Redundant components and concurrent repair High opportunity components—those that most affect system availability—are protected with redundancy and the ability to be repaired concurrently. The use of redundant components allows the system to remain operational: POWER7 cores, which include redundant bits in L1 instruction and data caches, L2 caches, and L2 and L3 directories Power 720 and 740 main memory DIMMs, which use an innovative ECC algorithm from IBM research that improves bit error correction and memory failures Redundant and hot-swap cooling Redundant and hot-swap power supplies Redundant 12X loops to I/O subsystem For maximum availability, be sure to connect power cords from the same system to two separate Power Distribution Units (PDUs) in the rack, and to connect each PDU to independent power sources. Tower form factor power cords must be plugged to two independent power sources in order to achieve maximum availability. 4.2 Availability IBM hardware and microcode capability to continuously monitor execution of hardware functions is generally described as the process of First Failure Data Capture (FFDC). This process includes the strategy of predictive failure analysis, which refers to the ability to track intermittent correctable errors and to vary components off-line before they reach the point of hard failure causing a system outage, and without the need to recreate the problem. The POWER7 family of systems continues to offer and introduce significant enhancements designed to increase system availability to drive towards a high availability objective with hardware components that can perform the following automatic functions: Self-diagnose and self-correct during run time Automatically reconfigure to mitigate potential problems from suspect hardware Self-heal or automatically substitute good components for failing components Tip: Check your configuration for optional redundant components before ordering your system. Note: POWER7 processor-based servers are independent of the operating system for error detection and fault isolation within the central electronics complex.
  • 148. 134 IBM Power 720 and 740: Technical Overview and Introduction Throughout this chapter we describe IBM POWER7 processor-based systems technologies focused on keeping a system up and running. For a specific set of functions focused on detecting errors before they become serious enough to stop computing work, see 4.3.1, “Detecting errors” on page 183. 4.2.1 Partition availability priority Also available is the ability to assign availability priorities to partitions. If an alternate processor recovery event requires spare processor resources and there are no other means of obtaining the spare resources, the system determines which partition has the lowest priority and attempts to claim the needed resource. On a properly configured POWER processor-based server, this approach allows that capacity to first be obtained from a low priority partition instead of a high priority partition. This capability is relevant to the total system availability because it gives the system an additional stage before an unplanned outage. In the event that insufficient resources exist to maintain full system availability, these servers attempt to maintain partition availability by user-defined priority. Partition availability priority is assign to partitions using a weight value or integer rating. The lowest priority partition is rated at 0 (zero) and the highest priority partition is valued at 255. The default value is set at 127 for standard partitions and 192 for Virtual I/O Server (VIOS) partitions. You can vary the priority of individual partitions. Partition availability priorities can be set for both dedicated and shared processor partitions. The POWER Hypervisor uses the relative partition weight value among active partitions to favor higher priority partitions for processor sharing, adding and removing processor capacity, and favoring higher priority partitions for normal operation. Note that the partition specifications for minimum, desired, and maximum capacity are also taken into account for capacity-on-demand options, and if total system-wide processor capacity becomes disabled because of deconfigured failed processor cores. For example, if total system-wide processor capacity is sufficient to run all partitions, at least with the minimum capacity, the partitions are allowed to start or continue running. If processor capacity is insufficient to run a partition at its minimum value, then starting that partition results in an error condition that must be resolved. 4.2.2 General detection and deallocation of failing components Runtime correctable or recoverable errors are monitored to determine if there is a pattern of errors. If these components reach a predefined error limit, the service processor initiates an action to deconfigure the faulty hardware, helping to avoid a potential system outage and to enhance system availability. Persistent deallocation To enhance system availability, a component that is identified for deallocation or deconfiguration on a POWER processor-based system is flagged for persistent deallocation. Component removal can occur either dynamically (while the system is running) or at boot-time (IPL), depending both on the type of fault and when the fault is detected.
  • 149. Chapter 4. Continuous availability and manageability 135 In addition, runtime unrecoverable hardware faults can be deconfigured from the system after the first occurrence. The system can be rebooted immediately after failure and resume operation on the remaining stable hardware. This way prevents the same faulty hardware from affecting system operation again; the repair action is deferred to a more convenient, less critical time. The following persistent deallocation functions are included: Processor L2/L3 cache lines (cache lines are dynamically deleted) Memory Deconfigure or bypass failing I/O adapters Figure 4-2 AMSI Auto Power Restart setting window interface Processor instruction retry As in POWER6, the POWER7 processor has the ability to do processor instruction retry and alternate processor recovery for a number of core related faults. Doing this significantly reduces exposure to both permanent and intermittent errors in the processor core. Note: The auto-restart (reboot) option has to be enabled from the Advanced System Manager Interface or from the Control (Operator) Panel. Figure 4-2 shows this option using the ASMI.
  • 150. 136 IBM Power 720 and 740: Technical Overview and Introduction Intermittent errors, often due to cosmic rays or other sources of radiation, are generally not repeatable. With the instruction retry function, when an error is encountered in the core, in caches and certain logic functions, the POWER7 processor first automatically retries the instruction. If the source of the error was truly transient, the instruction succeeds and the system can continue as before. Note that on IBM systems prior to POWER6, such an error typically caused a checkstop. Alternate processor retry Hard failures are more difficult, being permanent errors that will be replicated each time the instruction is repeated. Retrying the instruction does not help in this situation because the instruction will continue to fail. As in POWER6, POWER7 processors have the ability to extract the failing instruction from the faulty core and retry it elsewhere in the system for a number of faults, after which the failing core is dynamically deconfigured and scheduled for replacement. Dynamic processor deallocation Dynamic processor deallocation enables automatic deconfiguration of processor cores when patterns of recoverable core-related faults are detected. Dynamic processor deallocation prevents a recoverable error from escalating to an unrecoverable system error, which might otherwise result in an unscheduled server outage. Dynamic processor deallocation relies on the service processor’s ability to use FFDC-generated recoverable error information to notify the POWER Hypervisor when a processor core reaches its predefined error limit. Then the POWER Hypervisor dynamically deconfigures the failing core and is called out for replacement. The entire process is transparent to the partition owning the failing instruction. Single processor checkstop As in the POWER6 processor, the POWER7 processor provides single core check stopping for certain processor logic, command, or control errors that cannot be handled by the availability enhancements in the preceding section. This significantly reduces the probability of any one processor affecting total system availability by containing most processor checkstops to the partition that was using the processor at the time full checkstop goes into effect. Even with all these availability enhancements to prevent processor errors from affecting system-wide availability into play, there will be errors that can result in a system-wide outage. 4.2.3 Memory protection A memory protection architecture that provides good error resilience for a relatively small L1 cache might be very inadequate for protecting the much larger system main store. Therefore, a variety of protection methods are used in POWER processor-based systems to avoid uncorrectable errors in memory. Memory protection plans must take into account many factors, including these: Size Desired performance Memory array manufacturing characteristics
  • 151. Chapter 4. Continuous availability and manageability 137 POWER7 processor-based systems have a number of protection schemes designed to prevent, protect, or limit the effect of errors in main memory: Chipkill: Chipkill is an enhancement that enables a system to sustain the failure of an entire DRAM chip. An ECC word uses 18 DRAM chips from two DIMM pairs, and a failure on any of the DRAM chips can be fully recovered by the ECC algorithm. The system can continue indefinitely in this state with no performance degradation until the failed DIMM can be replaced. 72-byte ECC: In POWER7, an ECC word consists of 72 bytes of data. Of these, 64 are used to hold application data. The remaining eight bytes are used to hold check bits and additional information about the ECC word. This innovative ECC algorithm from IBM research works on DIMM pairs on a rank basis (a rank is a group of 9 DRAM chips on the Power 710 and 730). With this ECC code, the system can dynamically recover from an entire DRAM failure (Chipkill) but can also correct an error even if another symbol (a byte, accessed by a 2-bit line pair) experiences a fault (an improvement from the Double Error Detection/Single Error Correction ECC implementation found on the POWER6 processor-based systems). Hardware scrubbing: Hardware scrubbing is a method used to deal with intermittent errors. IBM POWER processor-based systems periodically address all memory locations; any memory locations with a correctable error are rewritten with the correct data. CRC: The bus that is transferring data between the processor and the memory uses CRC error detection with a failed operation-retry mechanism and the ability to dynamically retune bus parameters when a fault occurs. In addition, the memory bus has spare capacity to substitute a data bit-line, whenever it is determined to be faulty. POWER7 memory subsystem The POWER7 processor chip contains two memory controllers with four channels per Memory Controller. Each channel connects to a single DIMM, but as the channels work in pairs, a processor chip can address four DIMM pairs, two pairs per memory controller. The bus transferring data between the processor and the memory uses CRC error detection with a failed operation retry mechanism and the ability to dynamically retune bus parameters when a fault occurs. In addition, the memory bus has spare capacity to substitute a spare data bit-line for one which is determined to be faulty. Figure 4-3 on page 138 shows a POWER7 processor chip, with its memory interface, consisting of two controllers and four DIMMs per controller. Advanced memory buffer chips are exclusive to IBM and help to increase performance, acting as read/write buffers. On the Power 770 and 780, the advanced memory buffer chips are integrated to the DIMM that they support. Power 750 and 755 uses only one memory controller, Advanced memory buffer chips are on the system planar and support two DIMMs each.
  • 152. 138 IBM Power 720 and 740: Technical Overview and Introduction Figure 4-3 POWER7 memory subsystem Memory page deallocation While coincident cell errors in separate memory chips are statistically rare, IBM POWER processor-based systems can contain these errors using a memory page deallocation scheme for partitions running IBM AIX and the IBM i operating systems as well as for memory pages owned by the POWER Hypervisor. If a memory address experiences an uncorrectable or repeated correctable single cell error, the Service Processor sends the memory page address to the POWER Hypervisor to be marked for deallocation. Pages used by the POWER Hypervisor are deallocated as soon as the page is released. In other cases, the POWER Hypervisor notifies the owning partition that the page must be deallocated. Where possible, the operating system moves any data currently contained in that memory area to another memory area and removes the page(s) associated with this error from its memory map, no longer addressing these pages. The operating system performs memory page deallocation without any user intervention and is transparent to end users and applications. The POWER Hypervisor maintains a list of pages marked for deallocation during the current platform IPL. During a partition IPL, the partition receives a list of all the bad pages in its address space. In addition, if memory is dynamically added to a partition (through a dynamic LPAR operation), the POWER Hypervisor warns the operating system when memory pages are included that need to be deallocated. Finally, If an uncorrectable error in memory is discovered, the logical memory block associated with the address with the uncorrectable error is marked for deallocation by the POWER Hypervisor. This deallocation will take effect on a partition reboot if the logical memory block is assigned to an active partition at the time of the fault. Ctrl DIMMCtrl DIMM Memory Controller Ctrl DIMMCtrl DIMM Buffer Buffer Ctrl DIMMCtrl DIMM Memory Controller Ctrl DIMMCtrl DIMM BufferBuffer Port Port PortPort POWER7 Core 256 KB L2 POWER7 Core 256 KB L2 POWER7 Core 256 KB L2 POWER7 Core 256 KB L2 POWER7 Core 256 KB L2 POWER7 Core 256 KB L2 POWER7 Core 256 KB L2 POWER7 Core 256 KB L2 32 MB L3 Cache SMPFabric GX
  • 153. Chapter 4. Continuous availability and manageability 139 In addition, the system will deallocate the entire memory group associated with the error on all subsequent system reboots until the memory is repaired. This precaution is intended to guard against future uncorrectable errors while waiting for parts replacement. Memory persistent deallocation Defective memory discovered at boot time is automatically switched off. If the Service Processor detects a memory fault at boot time, it marks the affected memory as bad so it is not to be used on subsequent reboots. If the Service Processor identifies faulty memory in a server that includes CoD memory, the POWER Hypervisor attempts to replace the faulty memory with available CoD memory. Faulty resources are marked as deallocated and working resources are included in the active memory space. Because these activities reduce the amount of CoD memory available for future use, repair of the faulty memory must be scheduled as soon as is convenient. Upon reboot, if not enough memory is available to meet minimum partition requirements the POWER Hypervisor will reduce the capacity of one or more partitions. Depending on the configuration of the system, the HMC Service Focal Point, OS Service Focal Point, or Service Processor will receive a notification of the failed component, and will trigger a service call. 4.2.4 Cache protection POWER7 processor-based systems are designed with cache protection mechanisms, including cache line delete in both L2 and L3 arrays, Processor Instruction Retry and Alternate Processor Recovery protection on L1-I and L1-D, and redundant “Repair” bits in L1-I, L1-D, and L2 caches, as well as L2 and L3 directories. L1 instruction and data array protection The POWER7 processor instruction and data caches are protected against intermittent errors using Processor Instruction Retry and against permanent errors by Alternate Processor Recovery, both mentioned earlier. L1 cache is divided into sets. POWER7 processor can deallocate all but one before doing a Processor Instruction Retry. In addition, faults in the Segment Lookaside Buffer (SLB) array are recoverable by the POWER Hypervisor. The SLB is used in the core to perform address translation calculations. L2 and L3 array protection The L2 and L3 caches in the POWER7 processor are protected with double-bit detect single-bit correct error detection code (ECC). Single-bit errors are corrected before forwarding to the processor, and subsequently written back to L2/L3. In addition, the caches maintain a cache line delete capability. A threshold of correctable errors detected on a cache line can result in the data in the cache line being purged and the cache line removed from further operation without requiring a reboot. An ECC uncorrectable error detected in the cache can also trigger a purge and delete of the cache line. This results in no loss of operation because an unmodified copy of the data can be held on system memory to reload the cache line from main memory. Modified data is handled through Special Uncorrectable Error handling. L2 and L3 deleted cache lines are marked for persistent deconfiguration on subsequent system reboots until they can be replaced.
  • 154. 140 IBM Power 720 and 740: Technical Overview and Introduction 4.2.5 Special Uncorrectable Error handling While it is rare, an uncorrectable data error can occur in memory or a cache. IBM POWER processor-based systems attempt to limit the impact of an uncorrectable error to the least possible disruption, using a well-defined strategy that first considers the data source. Sometimes, an uncorrectable error is temporary in nature and occurs in data that can be recovered from another repository, for example: Data in the instruction L1 cache is never modified within the cache itself. Therefore, an uncorrectable error discovered in the cache is treated like an ordinary cache miss, and correct data is loaded from the L2 cache. The L2 and L3 cache of the POWER7 processor-based systems can hold an unmodified copy of data in a portion of main memory. In this case, an uncorrectable error simply triggers a reload of a cache line from main memory. In cases where the data cannot be recovered from another source, a technique called Special Uncorrectable Error (SUE) handling is used to prevent an uncorrectable error in memory or cache from immediately causing the system to terminate. Rather, the system tags the data and determines whether it will ever be used again: If the error is irrelevant, it will not force a checkstop. If the data is used, termination can be limited to the program / kernel or hypervisor owning the data; or freeze of the I/O adapters controlled by an I/O hub controller if data is going to be transferred to an I/O device. When an uncorrectable error is detected, the system modifies the associated ECC word, thereby signaling to the rest of the system that the “standard” ECC is no longer valid. The Service Processor is then notified, and takes appropriate actions. When running AIX V5.2 or later, or Linux, and a process attempts to use the data, the operating system is informed of the error and might terminate, or only terminate a specific process associated with the corrupt data, depending on the operating system and firmware level and whether the data was associated with a kernel or non-kernel process. It is only in the case where the corrupt data is used by the POWER Hypervisor that the entire system must be rebooted, thereby preserving overall system integrity. Depending on system configuration and source of the data, errors encountered during I/O operations might not result in a machine check. Instead, the incorrect data is handled by the processor host bridge (PHB) chip. When the PHB chip detects a problem, it rejects the data, preventing data being written to the I/O device. The PHB then enters a freeze mode halting normal operations. Depending on the model and type of I/O being used, the freeze might include the entire PHB chip, or simply a single bridge. resulting in the loss of all I/O operations that use the frozen hardware until a power-on reset of the PHB is done. The impact to partitions depends on how the I/O is configured for redundancy. In a server configured for failover availability, redundant adapters spanning multiple PHB chips can enable the system to recover transparently, without partition loss. 4.2.6 PCI extended error handling IBM estimates that PCI adapters can account for a significant portion of the hardware-based errors on a large server. Whereas servers that rely on boot-time diagnostics can identify failing components to be replaced by hot-swap and reconfiguration, runtime errors pose a more significant problem.
  • 155. Chapter 4. Continuous availability and manageability 141 PCI adapters are generally complex designs involving extensive on-board instruction processing, often on embedded micro controllers. They tend to use industry standard grade components with an emphasis on product cost relative to high reliability. In certain cases, they might be more likely to encounter internal microcode errors, or many of the hardware errors described for the rest of the server. The traditional means of handling these problems is through adapter internal error reporting and recovery techniques in combination with operating system device driver management and diagnostics. In certain cases, an error in the adapter might cause transmission of bad data on the PCI bus itself, resulting in a hardware detected parity error and causing a global machine check interrupt, eventually requiring a system reboot to continue. PCI extended error handling (EEH) enabled adapters respond to a special data packet generated from the affected PCI slot hardware by calling system firmware, which will examine the affected bus, allow the device driver to reset it, and continue without a system reboot. For Linux, EEH support extends to the majority of frequently used devices, although various third-party PCI devices might not provide native EEH support. To detect and correct PCIe bus errors POWER7 processor-based systems use CRC detection and instruction retry correction, while for PCI-X use ECC. Figure 4-4 shows the location and various mechanisms used throughout the I/O subsystem for PCI extended error handling. Figure 4-4 PCI extended error handling PCIe Adapter PCI-X Adapter Parity error Parity error I/O drawer concurrent add CRC with retry or ECC PCI Bridge Enhanced Error Handling PCI-X to PCI-X POWER7 12X Channel Hub PCI-X Bridge PCI-X Bridge POWER7 12X Channel Hub 12X Channel – PCIe Bridge GX+ / GX++ bus adapter 12x channel failover support PCI Bus Enhanced Error Handling
  • 156. 142 IBM Power 720 and 740: Technical Overview and Introduction 4.3 Serviceability IBM Power Systems design considers both IBM and client needs. The IBM Serviceability Team has enhanced the base service capabilities and continues to implement a strategy that incorporates best-of-breed service characteristics from diverse IBM systems offerings. Serviceability includes system installation, system upgrades and downgrades (MES), and system maintenance and repair. The goal of the IBM Serviceability Team is to design and provide the most efficient system service environment, which includes the following benefits: Easy access to service components; design for Customer Set Up (CSU), Customer Installed Features (CIF), and Customer Replaceable Units (CRU) On demand service education Error detection and fault isolation (ED/FI) First-failure data capture (FFDC) An automated guided repair strategy that uses common service interfaces for a converged service approach across multiple IBM server platforms By delivering on these goals, IBM Power Systems servers enable faster and more accurate repair, and reduce the possibility of human error. Client control of the service environment extends to firmware maintenance on all of the POWER processor-based systems. This strategy contributes to higher systems availability with reduced maintenance costs. This section provides an overview of the progressive steps of error detection, analysis, reporting, notifying, and repairing that are found in all POWER processor-based systems. The term servicer, when used in the context of this document, denotes the person tasked with performing service related actions on a system. For an item designated as a Customer Replaceable Unit (CRU), the servicer might be the client. In other cases, for Field Replaceable Unit (FRU) items, the servicer might be an IBM representative or an authorized warranty service provider. Service can be divided into three main categories: Service Components The basic service related building blocks Service Functions Service procedures or processes containing one or more service components Service Operating Environment The specific system operating environment which specifies how service functions are provided by the various service components The basic component of service is a Serviceable Event. Serviceable events are platform, regional, and local error occurrences that require a service action (repair). This action can include a call home to report the problem so that the repair can be assessed by a trained service representative. In all cases, the client is notified of the event. Event notification includes a clear indication of when servicer intervention is required to rectify the problem. The intervention might be a service action that the client can perform or it might require a service provider.
  • 157. Chapter 4. Continuous availability and manageability 143 Serviceable events are classified as follows: 1. Recoverable: This is a correctable resource or function failure. The server remains available, but there might be some decrease in operational performance available for client’s workload (applications). 2. Unrecoverable: This is an uncorrectable resource or function failure. In this instance, there is potential degradation in availability and performance, or loss of function to the client’s workload. 3. Predictable (using thresholds in support of Predictive Failure Analysis): This is a determination that continued recovery of a resource or function might lead to degradation of performance or failure of the client’s workload. Although the server remains fully available, if the condition is not corrected, an unrecoverable error might occur. 4. Informational: This is notification that a resource or function: – Is out-of or returned-to specification and might require user intervention. – Requires user intervention to complete a system task(s). Platform errors are faults that affect all partitions in various ways. They are detected in the CEC by the Service Processor, the System Power Control Network, or the Power Hypervisor. When a failure occurs in these components, the POWER Hypervisor notifies each partition’s operating system to execute any required precautionary actions or recovery methods. The OS is required to report these kinds of errors as serviceable events to the Service Focal Point application because, by the definition, they affect the partition. Platform errors are faults related to: The Central Electronics Complex (CEC); that part of the server composed of the central processor units, memory, storage controls, and the I/O hubs. The power and cooling subsystems. The firmware used to initialize the system and diagnose errors. Regional errors are faults that affect some, but not all partitions. They are detected by the POWER Hypervisor or the Service Processor. Examples of these are RIO bus, RIO bus adapter, PHB, multi-adapter bridges, I/O hub, and errors on I/O units (except adapters, devices, and their connecting hardware). Local errors are faults detected in a partition (by the partition firmware or the operating system) for resources owned only by that partition. The POWER Hypervisor and Service Processor are not aware of these errors. Local errors might include “secondary effects” that result from platform errors preventing partitions from accessing partition-owned resources. Examples include PCI adapters or devices assigned to a single partition. If a failure occurs to one of these resources, only a single operating system partition need be informed. This section provides an overview of the progressive steps of error detection, analysis, reporting, notifying, and repairing that are found in all POWER processor-based systems. 4.3.1 Detecting The first and most crucial component of a solid serviceability strategy is the ability to accurately and effectively detect errors when they occur. Although not all errors are a guaranteed threat to system availability, those that go undetected can cause problems because the system does not have the opportunity to evaluate and act if necessary. POWER processor-based systems employ IBM System z® server-inspired error detection mechanisms that extend from processor cores and memory to power supplies and hard drives.
  • 158. 144 IBM Power 720 and 740: Technical Overview and Introduction Service processor The service processor is a microprocessor that is powered separately from the main instruction processing complex. The service processor provides the capabilities for the following features: POWER Hypervisor (system firmware) and Hardware Management Console connection surveillance Various remote power control options Reset and boot features Environmental monitoring: The service processor monitors the server’s built-in temperature sensors, sending instructions to the system fans to increase rotational speed when the ambient temperature is above the normal operating range. Using an architected operating system interface, the service processor notifies the operating system of potential environmentally related problems so that the system administrator can take appropriate corrective actions before a critical failure threshold is reached. The service processor can also post a warning and initiate an orderly system shutdown under the following circumstances: – The operating temperature exceeds the critical level (for example, failure of air conditioning or air circulation around the system). – The system fan speed is out of operational specification, for example, because of multiple fan failures. – The server input voltages are out of operational specification. The service processor can immediately shut down a system when: – Temperature exceeds the critical level or remains above the warning level for too long. – Internal component temperatures reach critical levels. – Non-redundant fan failures occur. Placing calls: On systems without a Hardware Management Console, the service processor can place calls to report surveillance failures with the POWER Hypervisor, critical environmental faults, and critical processing faults even when the main processing unit is inoperable. Mutual surveillance: The service processor monitors the operation of the POWER Hypervisor firmware during the boot process and watches for loss of control during system operation. It also allows the POWER Hypervisor to monitor service processor activity. The service processor can take appropriate action, including calling for service, when it detects the POWER Hypervisor firmware has lost control. Likewise, the POWER Hypervisor can request a service processor repair action if necessary. Availability: The auto-restart (reboot) option, when enabled, can reboot the system automatically following an unrecoverable firmware error, firmware hang, hardware failure, or environmentally induced (AC power) failure. Fault monitoring: Built-in self-test (BIST) checks processor, cache, memory, and associated hardware that is required for proper booting of the operating system, when the system is powered on at the initial installation or after a hardware configuration change (for example, an upgrade). If a non-critical error is detected or if the error occurs in a resource that can be removed from the system configuration, the booting process is designed to proceed to completion.
  • 159. Chapter 4. Continuous availability and manageability 145 The errors are logged in the system nonvolatile random access memory (NVRAM). When the operating system completes booting, the information is passed from the NVRAM to the system error log where it is analyzed by error log analysis (ELA) routines. Appropriate actions are taken to report the boot-time error for subsequent service, if required Concurrent access to the service processors menus of the Advanced System Management Interface (ASMI): This access allows nondisruptive abilities to change system default parameters, interrogate service processor progress and error logs, set and reset server indicators, (Guiding Light for midrange and high-end servers, Light Path for low end servers), indeed, accessing all service processor functions without having to power-down the system to the standby state. This way allows the administrator or service representative to dynamically access the menus from any web browser-enabled console that is attached to the Ethernet service network, concurrently with normal system operation. Managing the interfaces for connecting uninterruptable power source systems to the POWER processor-based systems, performing Timed Power-On (TPO) sequences, and interfacing with the power and cooling subsystems. Error checkers IBM POWER processor-based systems contain specialized hardware detection circuitry that is used to detect erroneous hardware operations. Error checking hardware ranges from parity error detection coupled with processor instruction retry and bus retry, to ECC correction on caches and system buses. All IBM hardware error checkers have distinct attributes: Continuous monitoring of system operations to detect potential calculation errors Attempts to isolate physical faults based on run time detection of each unique failure Ability to initiate a wide variety of recovery mechanisms designed to correct the problem. The POWER processor-based systems include extensive hardware and firmware recovery logic. Fault isolation registers Error checker signals are captured and stored in hardware fault isolation registers (FIRs). The associated logic circuitry is used to limit the domain of an error to the first checker that encounters the error. In this way, run-time error diagnostics can be deterministic so that for every check station, the unique error domain for that checker is defined and documented. Ultimately, the error domain becomes the field-replaceable unit (FRU) call, and manual interpretation of the data is not normally required. First-failure data capture The first-failure data capture (FFDC) error isolation technique ensures that when a fault is detected in a system through error checkers or other types of detection methods, the root cause of the fault will be captured without the need to re-create the problem or run an extended tracing or diagnostics program. For the vast majority of faults, a good FFDC design means that the root cause is detected automatically without intervention by a service representative. Pertinent error data related to the fault is captured and saved for analysis. In hardware, FFDC data is collected from the fault isolation registers (FIRs) and from the associated logic. In firmware, this data consists of return codes, function calls, and so forth. FFDC check stations are carefully positioned within the server logic and data paths to ensure that potential errors can be quickly identified and accurately tracked to a field-replaceable unit (FRU).
  • 160. 146 IBM Power 720 and 740: Technical Overview and Introduction This proactive diagnostic strategy is a significant improvement over the classic, less accurate reboot and diagnose service approaches. Figure 4-5 shows a schematic of a fault isolation register implementation. Figure 4-5 Schematic of FIR implementation Note: First Failure Data Capture plays a critical role in delivering servers that can self-diagnose and self-heal. Using thousands of checkers (diagnostic probes) deployed at critical junctures throughout the server, the system effectively “traps” hardware errors at system run time. The separately powered Service Processor is then used to analyze the checkers and perform problem determination. Using this method, IBM no longer has to rely on an intermittent “reboot and retry” error detection strategy, but knows with a degree of certainty which part is having problems. In this automated approach, run-time error diagnostics can be deterministic, so that for every check station, the unique error domain for that checker is defined and documented. Ultimately, the error domain becomes the FRU (part) call, and manual interpretation of the data is not normally required. This architecture is also the basis for the IBM predictive failure analysis, because the Service Processor can now count, and log, intermittent component errors, and can deallocate or take other corrective actions when an error threshold is reached. Memory CPU L2 / L3 Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text L1 Disk Text Text Text Text Text Text Text Text Non-volatile RAM Service Processor Error checkers Text Fault isolation register (FIR) Unique fingerprint of each captured error Log error
  • 161. Chapter 4. Continuous availability and manageability 147 Fault isolation The service processor interprets error data that is captured by the FFDC checkers (saved in the FIRs or other firmware-related data capture methods) in order to determine the root cause of the error event. Root cause analysis might indicate that the event is recoverable, meaning that a service action point or need for repair has not been reached. Alternatively, it might indicate that a service action point has been reached, where the event exceeded a pre-determined threshold or was unrecoverable. Based on the isolation analysis, recoverable error threshold counts might be incremented. No specific service action is necessary when the event is recoverable. When the event requires a service action, additional required information is collected to service the fault. For unrecoverable errors or for recoverable events that meet or exceed their service threshold, meaning that a service action point has been reached, a request for service is initiated through an error logging component. 4.3.2 Diagnosing Using the extensive network of advanced and complementary error detection logic that is built directly into hardware, firmware, and operating systems, the IBM Power Systems servers can perform considerable self-diagnosis. Boot time When an IBM Power Systems server powers up, the service processor initializes system hardware. Boot-time diagnostic testing uses a multitier approach for system validation, starting with managed low level diagnostics that are supplemented with system firmware initialization and configuration of I/O hardware, followed by OS-initiated software test routines. The following boot-time diagnostic routines are included: Built-in self-tests (BIST) for both logic components and arrays ensure the internal integrity of components. Because the service processor assists in performing these tests, the system is enabled to perform fault determination and isolation, whether or not the system processors are operational. Boot-time BISTs can also find faults undetectable by processor-based power-on self-test (POST) or diagnostics Wire-tests discover and precisely identify connection faults between components such as processors, memory, or I/O hub chips. Initialization of components such as ECC memory, typically by writing patterns of data and allowing the server to store valid ECC data for each location, can help isolate errors. To minimize boot time, the system determines which of the diagnostics are required to be started in order to ensure correct operation, based on the way the system was powered off, or on the boot-time selection menu. Run time All Power Systems servers can monitor critical system components during run time, and they can take corrective actions when recoverable faults occur. IBM hardware error-check architecture provides the ability to report non-critical errors in an out-of-band communications path to the service processor without affecting system performance. A significant part of IBM runtime diagnostic capabilities originate with the service processor. Extensive diagnostic and fault analysis routines have been developed and improved over many generations of POWER processor-based servers, and enable quick and accurate predefined responses to both actual and potential system problems.
  • 162. 148 IBM Power 720 and 740: Technical Overview and Introduction The service processor correlates and processes runtime error information, using logic derived from IBM engineering expertise to count recoverable errors (called thresholding) and predict when corrective actions must be automatically initiated by the system. The following actions are included: Requests for a part to be replaced Dynamic invocation of built-in redundancy for automatic replacement of a failing part Dynamic deallocation of failing components so that system availability is maintained Device drivers In certain cases, diagnostics are best performed by operating system-specific drivers, most notably, I/O devices that are owned directly by a logical partition. In these cases, the operating system device driver often works in conjunction with the I/O device microcode to isolate and recover from problems. Potential problems are reported to an operating system device driver, which logs the error. I/O devices can also include specific exercisers that can be invoked by the diagnostic facilities for problem recreation if required by service procedures. 4.3.3 Reporting In the unlikely event that a system hardware or environmentally induced failure is diagnosed, IBM Power Systems servers report the error through a number of mechanisms. The analysis result is stored in system NVRAM. Error log analysis (ELA) can be used to display the failure cause and the physical location of the failing hardware. With the integrated service processor, the system has the ability to automatically send out an alert through a phone line to a pager, or call for service in the event of a critical system failure. A hardware fault also illuminates the amber system fault LED located on the system unit to alert the user of an internal hardware problem. On POWER7 processor-based servers, hardware and software failures are recorded in the system log. When an HMC is attached, an ELA routine analyzes the error, forwards the event to the Service Focal Point (SFP) application running on the HMC, and notifies the system administrator that it has isolated a likely cause of the system problem. The service processor event log also records unrecoverable checkstop conditions, forwards them to the SFP application, and notifies the system administrator. After the information is logged in the SFP application, if the system is properly configured, a call-home service request is initiated and the pertinent failure data with service parts information and part locations is sent to an IBM service organization. Client contact information and specific system-related data such as the machine type, model, and serial number, along with error log data related to the failure are sent to IBM Service. Error logging and analysis When the root cause of an error has been identified by a fault isolation component, an error log entry is created with basic data such as the following examples: An error code uniquely describing the error event The location of the failing component The part number of the component to be replaced, including pertinent data such as engineering and manufacturing levels Return codes Resource identifiers FFDC data
  • 163. Chapter 4. Continuous availability and manageability 149 Data containing information about the effect that the repair will have on the system is also included. Error log routines in the operating system can then use this information and decide to call home to contact service and support, send a notification message, or continue without an alert. Remote support The Remote Management and Control (RMC) application is delivered as part of the base operating system, including the operating system running on the Hardware Management Console. RMC provides a secure transport mechanism across the LAN interface between the operating system and the Hardware Management Console and is used by the operating system diagnostic application for transmitting error information. It performs a number of other functions also, but these are not used for the service infrastructure. Service Focal Point A critical requirement in a logically partitioned environment is to ensure that errors are not lost before being reported for service, and that an error must only be reported once, regardless of how many logical partitions experience the potential effect of the error. The Manage Serviceable Events task on the Hardware Management Console (HMC) is responsible for aggregating duplicate error reports, and ensures that all errors are recorded for review and management. When a local or globally reported service request is made to the operating system, the operating system diagnostic subsystem uses the Remote Management and Control Subsystem (RMC) to relay error information to the Hardware Management Console. For global events (platform unrecoverable errors, for example) the service processor will also forward error notification of these events to the Hardware Management Console, providing a redundant error-reporting path in case of errors in the RMC network. The first occurrence of each failure type is recorded in the Manage Serviceable Events task on the Hardware Management Console. This task then filters and maintains a history of duplicate reports from other logical partitions on the service processor. It then looks at all active service event requests, analyzes the failure to ascertain the root cause and, if enabled, initiates a call home for service. This methodology ensures that all platform errors will be reported through at least one functional path, ultimately resulting in a single notification for a single problem. Extended error data (EED) Extended error data (EED) is additional data that is collected either automatically at the time of a failure or manually at a later time. The data collected is dependent on the invocation method but includes information such as firmware levels, operating system levels, additional fault isolation register values, recoverable error threshold register values, system status, and any other pertinent data. The data is formatted and prepared for transmission back to IBM to assist the service support organization with preparing a service action plan for the service representative or for additional analysis. System dump handling In certain circumstances, an error might require a dump to be automatically or manually created. In this event, it is off-loaded to the HMC upon the reboot. Specific HMC information is included as part of the information that can optionally be sent to IBM support for analysis. If additional information relating to the dump is required, or if it becomes necessary to view the dump remotely, the HMC dump record notifies the IBM support center regarding on which HMC the dump is located.
  • 164. 150 IBM Power 720 and 740: Technical Overview and Introduction 4.3.4 Notifying After a Power Systems server has detected, diagnosed, and reported an error to an appropriate aggregation point, it then takes steps to notify the client, and if necessary, the IBM support organization. Depending upon the assessed severity of the error and support agreement, this might range from a simple notification to having field service personnel automatically dispatched to the client site with the correct replacement part. Client Notify When an event is important enough to report, but does not indicate the need for a repair action or the need to call home to IBM service and support, it is classified as Client Notify. Clients are notified because these events might be of interest to an administrator. The event might be a symptom of an expected systemic change, such as a network reconfiguration or failover testing of redundant power or cooling systems. Examples of these events include: Network events such as the loss of contact over a local area network (LAN) Environmental events such as ambient temperature warnings Events that need further examination by the client (although these events do not necessarily require a part replacement or repair action) Client Notify events are serviceable events, by definition, because they indicate that something has happened that requires client awareness in the event the client wants to take further action. These events can always be reported back to IBM at the client’s discretion. Call home A correctly configured POWER processor-based system can initiate an automatic or manual call from a client location to the IBM service and support organization with error data, server status, or other service-related information. The call-home feature invokes the service organization in order for the appropriate service action to begin, automatically opening a problem report, and in certain cases, also dispatching field support. This automated reporting provides faster and potentially more accurate transmittal of error information. Although configuring call-home is optional, clients are strongly encouraged to configure this feature in order to obtain the full value of IBM service enhancements. Vital product data (VPD) and inventory management Power Systems store vital product data (VPD) internally, which keeps a record of how much memory is installed, how many processors are installed, manufacturing level of the parts, and so on. These records provide valuable information that can be used by remote support and service representatives, enabling them to provide assistance in keeping the firmware and software on the server up-to-date. IBM problem management database At the IBM support center, historical problem data is entered into the IBM Service and Support Problem Management database. All of the information that is related to the error, along with any service actions taken by the service representative, are recorded for problem management by the support and development organizations. The problem is then tracked and monitored until the system fault is repaired. 4.3.5 Locating and servicing The final component of a comprehensive design for serviceability is the ability to effectively locate and replace parts requiring service. POWER processor-based systems use a combination of visual cues and guided maintenance procedures to ensure that the identified part is replaced correctly, every time.
  • 165. Chapter 4. Continuous availability and manageability 151 Packaging for service The following service enhancements are included in the physical packaging of the systems to facilitate service: Color coding (touch points): – Terracotta-colored touch points indicate that a component (FRU or CRU) can be concurrently maintained. – Blue-colored touch points delineate components that are not concurrently maintained (those that require the system to be turned off for removal or repair). Tool-less design: Selected IBM systems support tool-less or simple tool designs. These designs require no tools or simple tools such as flathead screw drivers to service the hardware components. Positive retention: Positive retention mechanisms help to assure proper connections between hardware components, such as from cables to connectors, and between two cards that attach to each other. Without positive retention, hardware components run the risk of becoming loose during shipping or installation, preventing a good electrical connection. Positive retention mechanisms such as latches, levers, thumb-screws, pop Nylatches (U-clips), and cables are included to help prevent loose connections and aid in installing (seating) parts correctly. These positive retention items do not require tools. Light Path The Light Path LED feature is supported by the Power 710, 720, 730, 740, 750, and the 755 servers. In the Light Path LED implementation, when a fault condition is detected on the POWER7 processor-based system, an amber FRU fault LED is illuminated, which is then rolled up to the system fault LED. The Light Path system pinpoints the exact part by turning on the amber FRU fault LED that is associated with the part to be replaced. The system can clearly identify components for replacement by using specific component-level LEDs, and can also guide the servicer directly to the component by signaling (staying on solid) the system fault LED, enclosure fault LED, and the component FRU fault LED. After the repair, the LEDs shut off automatically if the problem is fixed. Guiding Light The enclosure and system identify LEDs that turn on solid and that can be used to follow the path from the system to the enclosure and down to the specific FRU. Guiding Light uses a series of flashing LEDs, allowing a service provider to quickly and easily identify the location of system components. Guiding Light can also handle multiple error conditions simultaneously, which might be necessary in certain very complex high-end configurations. In these situations, Guiding Light waits for the servicer’s indication of what failure to attend first and then illuminates the LEDs to the failing component. Data centers can be complex places, and Guiding Light is designed to do more than identify visible components. When a component might be hidden from view, Guiding Light can flash a sequence of LEDs that extend to the frame exterior, clearly guiding the service representative to the correct rack, system, enclosure, drawer, and component.
  • 166. 152 IBM Power 720 and 740: Technical Overview and Introduction Service labels Service providers use these labels to assist them in performing maintenance actions. Service labels are found in various formats and positions, and are intended to transmit readily available information to the servicer during the repair process. Various service labels and the purpose of each are described in the following list: Location diagrams are strategically located on the system hardware, relating information regarding the placement of hardware components. Location diagrams can include location codes, drawings of physical locations, concurrent maintenance status, or other data that is pertinent to a repair. Location diagrams are especially useful when multiple components are installed such as DIMMs, CPUs, processor books, fans, adapter cards, LEDs, and power supplies. Remove or replace procedure labels contain procedures often found on a cover of the system or in other spots that are accessible to the servicer. These labels provide systematic procedures, including diagrams, detailing how to remove and replace certain serviceable hardware components. Numbered arrows are used to indicate the order of operation and serviceability direction of components. Various serviceable parts such as latches, levers, and touch points must be pulled or pushed in a certain direction and certain order so that the mechanical mechanisms can engage or disengage. Arrows generally improve the ease of serviceability. The operator panel The operator panel on a Power 720 and Power 740 is a four-row by 16-element LCD display that is used to present boot progress codes, indicating advancement through the system power-on and initialization processes. The operator panel is also used to display error and location codes when an error occurs that prevents the system from booting. It includes various buttons, enabling a service support representative or client to change various boot-time options and f other limited service functions. Concurrent maintenance The IBM POWER7 processor-based systems are designed with the understanding that certain components have higher intrinsic failure rates than others. The movement of fans, power supplies, and physical storage devices naturally make them more susceptible to wearing down or burning out; other devices such as I/O adapters can begin to wear from repeated plugging and unplugging. For these reasons, these devices have been specifically designed to be concurrently maintainable, when properly configured. In other cases, a client might be in the process of moving or redesigning a data center, or planning a major upgrade. At times like these, flexibility is crucial. The IBM POWER7 processor-based systems are designed for redundant or concurrently maintainable power, fans, physical storage, and I/O towers. The most recent members of the IBM Power Systems family, based on the POWER7 processor, continue to support concurrent maintenance of power, cooling, media devices, I/O drawers, GX adapter, and the operator panel. In addition, they support concurrent firmware fixpack updates when possible. The determination of whether a firmware fixpack release can be updated concurrently is identified in the readme file that is released with the firmware. Firmware updates Firmware updates for Power Systems are released in a cumulative sequential fix format, packaged as an RPM for concurrent application and activation. Administrators can install and activate many firmware patches without cycling power or rebooting the server.
  • 167. Chapter 4. Continuous availability and manageability 153 When an HMC is connected to the system, the new firmware image is loaded using any of the following methods: IBM distributed media, such as a CD-ROM A Problem Fix distribution from the IBM Service and Support repository FTP from another server Download from the IBM Fix Central website: http://www.ibm.com/support/fixcentral/ IBM supports multiple firmware releases in the field. Therefore, under expected circumstances, a server can operate on an existing firmware release, using concurrent firmware fixes to stay up-to-date with the current patch level. Because changes to various server functions (for example, changing initialization values for chip controls) cannot occur during system operation, a patch in this area requires a system reboot for activation. Under normal operating conditions, IBM provides patches for an individual firmware release level for up to two years after first making the release code generally available. After this period, clients must plan to update in order to stay on a supported firmware release. Activation of new firmware functions, as opposed to patches, require installation of a new firmware release level. This process is disruptive to server operations because it requires a scheduled outage and full server reboot. In addition to concurrent and disruptive firmware updates, IBM also offers concurrent patches, which include functions that are not activated until a subsequent server reboot. A server with these patches can operate normally. The additional concurrent fixes can be installed and activated when the system reboots after the next scheduled outage. Additional capability is being added to the firmware to be able to view the status of a system power control network background firmware update. This subsystem can update as necessary, as migrated nodes or I/O drawers are added to the configuration. The new firmware provides an interface to be able to view the progress of the update, and also control starting and stopping of the background update if a more convenient time becomes available. Repair and verify Repair and verify (R&V) is a system used to guide a service provider step-by-step through the process of repairing a system and verifying that the problem has been repaired. The steps are customized in the appropriate sequence for the particular repair for the specific system being repaired. Repair scenarios covered by repair and verify include: Replacing a defective field-replaceable unit (FRU) Reattaching a loose or disconnected component Correcting a configuration error Removing or replacing an incompatible FRU Updating firmware, device drivers, operating systems, middleware components, and IBM applications after replacing a part Installing a new part Repair and verify procedures can be used by both service representative providers who are familiar with the task and those who are not. Education On Demand content is placed in the procedure at the appropriate locations. Throughout the repair and verify procedure, repair history is collected and provided to the Service and Support Problem Management Database for storage with the serviceable event, to ensure that the guided maintenance procedures are operating correctly.
  • 168. 154 IBM Power 720 and 740: Technical Overview and Introduction Clients can subscribe through the subscription services to obtain the notifications about the latest updates available for service-related documentation. The latest version of the documentation is accessible through the Internet; a CD-ROM version is also available. 4.4 Manageability Several functions and tools help manageability, and enable you to efficiently and effectively manage your system. 4.4.1 Service user interfaces The Service Interface allows support personnel or the client to communicate with the service support applications in a server using a console, interface, or terminal. Delivering a clear, concise view of available service applications, the Service Interface allows the support team to manage system resources and service information in an efficient and effective way. Applications available through the Service Interface are carefully configured and placed to give service providers access to important service functions. Various service interfaces are used, depending on the state of the system and its operating environment. The primary service interfaces are: Light Path and Guiding Light For more information, see “Light Path” on page 151 and “Guiding Light” on page 151. Service processor; Advanced System Management Interface (ASMI) Operator panel Operating system service menu Service Focal Point on the Hardware Management Console Service Focal Point Lite on Integrated Virtualization Manager Service processor The service processor is a controller that is running its own operating system. It is a component of the service interface card. The service processor operating system has specific programs and device drivers for the service processor hardware. The host interface is a processor support interface that is connected to the POWER processor. The service processor is always working, regardless of main system unit’s state. The system unit can be in the following states: Standby (power off) Operating, ready to start partitions Operating with running logical partitions Functions The service processor is used to monitor and manage the system hardware resources and devices. The service processor checks the system for errors, ensuring the connection to the HMC for manageability purposes and accepting Advanced System Management Interface (ASMI) Secure Sockets Layer (SSL) network connections. The service processor provides the ability to view and manage the machine-wide settings by using the ASMI, and enables complete system and partition management from the HMC.
  • 169. Chapter 4. Continuous availability and manageability 155 The service processor uses two Ethernet 10/100Mbps ports. Note the following information: Both Ethernet ports are only visible to the service processor and can be used to attach the server to an HMC or to access the ASMI. The ASMI options can be accessed through an HTTP server that is integrated into the service processor operating environment. Both Ethernet ports support only auto-negotiation. Customer selectable media speed and duplex settings are not available. Both Ethernet ports have a default IP address, as follows: – Service processor Eth0 or HMC1 port is configured as 169.254.2.147 – Service processor Eth1 or HMC2 port is configured as 169.254.3.147 The functions available through service processor include: Call Home Advanced System Management Interface (ASMI) Error Information (error code, PN, Location Codes) menu View of guarded components Limited repair procedures Generate dump LED Management menu Remote view of ASMI menus Firmware update through USB key Advanced System Management Interface (ASMI) ASMI is the interface to the service processor that enables you to manage the operation of the server, such as auto-power restart, and to view information about the server, such as the error log and vital product data. Various repair procedures require connection to the ASMI. The ASMI is accessible through the HMC. It is also accessible by using a web browser on a system that is connected directly to the service processor (in this case, either a standard Ethernet cable or a crossed cable) or through an Ethernet network. ASMI can also be accessed from an ASCII terminal. Use the ASMI to change the service processor IP addresses or to apply certain security policies and prevent access from undesired IP addresses or ranges. You might be able to use the service processor’s default settings. In that case, accessing the ASMI is not necessary. To access ASMI, use one of the following steps: Access the ASMI by using an HMC. If configured to do so, the HMC connects directly to the ASMI for a selected system from this task. To connect to the Advanced System Management interface from an HMC, follow these steps: a. Open Systems Management from the navigation pane. b. From the work pane, select one or more managed systems to work with. c. From the System Management tasks list, select Operations Advanced System Management (ASM). Note: The service processor enables a system that does not boot to be analyzed. The error log analysis can be performed from either the ASMI or the HMC.
  • 170. 156 IBM Power 720 and 740: Technical Overview and Introduction Access the ASMI by using a web browser. The web interface to the ASMI is accessible through Microsoft® Internet Explorer 6.0, Microsoft Internet Explorer 7, Netscape 7.1, Mozilla Firefox, or Opera 7.23 running on a PC or mobile computer that is connected to the service processor. The web interface is available during all phases of system operation, including the initial program load (IPL) and run time. However, a few of the menu options in the web interface are unavailable during IPL or run time to prevent usage or ownership conflicts if the system resources are in use during that phase. The ASMI provides a Secure Sockets Layer (SSL) web connection to the service processor. To establish an SSL connection, open your browser using the address: https://<ip_address_of_service_processor> (where <ip_address_of_service_processor> is the address of the service processor of your Power Systems server, such as 9.166.196.7). Access the ASMI using an ASCII terminal. The ASMI on an ASCII terminal supports a subset of the functions that are provided by the web interface and is available only when the system is in the platform standby state. The ASMI on an ASCII console is not available during various phases of system operation, such as the IPL and run time. The operator panel The service processor provides an interface to the operator panel, which is used to display system status and diagnostic information. The operator panel can be accessed in two ways: By using the normal operational front view By pulling it out to access the switches and view the LCD display. Figure 4-6 on page 157 shows that the operator panel on a Power 720 and 740 is pulled out. Note: To make the connection through Internet Explorer, click Tools Internet Options. Clear the Use TLS 1.0 check box, and click OK.
  • 171. Chapter 4. Continuous availability and manageability 157 Figure 4-6 Operator panel is pulled out from the chassis The operator panel includes features such as these: A 2 x 16 character LCD display Reset, enter, power On/Off, increment and decrement buttons Amber System Information/Attention, green Power LED Blue Enclosure Identify LED on the Power 720 and 740 Altitude sensor USB Port Speaker/Beeper The following functions are available through the operator panel: Error Information Generate dump View Machine Type, Model and Serial Number Limited set of repair functions Operating system service menu The system diagnostics consist of IBM i service tools, stand-alone diagnostics that are loaded from the DVD drive, and online diagnostics (available in AIX). Online diagnostics, when installed, are a part of the AIX or IBM i operating system on the disk or server. They can be booted in single-user mode (service mode), run in maintenance mode, or run concurrently (concurrent mode) with other applications. They have access to the AIX error log and the AIX configuration data. IBM i has a service tools problem log, IBM i history log (QHST), and IBM i problem log. Release Lever (slide left to release operator panel and pull out from chassis)
  • 172. 158 IBM Power 720 and 740: Technical Overview and Introduction The available modes are as follows: Service mode: Requires a service mode boot of the system, enables the checking of system devices and features. Service mode provides the most complete checkout of the system resources. All system resources, except the SCSI adapter and the disk drives used for paging, can be tested. Concurrent mode: Enables the normal system functions to continue while selected resources are being checked. Because the system is running in normal operation, certain devices might require additional actions by the user or diagnostic application before testing can be done. Maintenance mode: Enables the checking of most system resources. Maintenance mode provides the same test coverage as service mode. The difference between the two modes is the way they are invoked. Maintenance mode requires that all activity on the operating system be stopped. The shutdown -m command is used to stop all activity on the operating system and put the operating system into maintenance mode. The System Management Services (SMS) error log is accessible on the SMS menus. This error log contains errors that are found by partition firmware when the system or partition is booting. You can access the service processor’s error log on the ASMI menus. You can also access the system diagnostics from an AIX Network Installation Management (NIM) server. The IBM i operating system and associated machine code provide Dedicated Service Tools (DST) as part of the IBM i licensed machine code (Licensed Internal Code) and System Service Tools (SST) as part of the IBM i operating system. DST can be run in dedicated mode (no operating system loaded). DST tools and diagnostics are a superset of those available under SST. The IBM i End Subsystem (ENDSBS *ALL) command can shut down all IBM and customer applications subsystems except the controlling subsystem QTCL. The Power Down System (PWRDWNSYS) command can be set to power down the IBM i partition and restart the partition in DST mode. You can start SST during normal operations, which leaves all applications up and running, using the IBM i Start Service Tools (STRSST) command (when signed onto IBM i with the appropriately secured user ID). With DST and SST, you can look at various logs, run various diagnostics, or take various kinds of system dumps or other options. Depending on the operating system, the service-level functions that you typically see when using the operating system service menus are as follows: Product activity log Trace Licensed Internal Code Work with communications trace Note: When your order a Power System, a DVD-ROM or DVD-RAM might be optional. An alternate method for maintaining and servicing the system must be available if you do not order the DVD-ROM or DVD-RAM.
  • 173. Chapter 4. Continuous availability and manageability 159 Display/Alter/Dump Licensed Internal Code log Main storage dump manager Hardware service manager Call Home/Customer Notification Error information menu LED management menu Concurrent/Non-concurrent maintenance (within scope of the OS) Managing firmware levels – Server – Adapter Remote support (access varies by OS) Service Focal Point on the Hardware Management Console Service strategies become more complicated in a partitioned environment. The Manage Serviceable Events task in the HMC can help to streamline this process. Each logical partition reports errors that it detects and forwards the event to the Service Focal Point (SFP) application that is running on the HMC, without determining whether other logical partitions also detect and report the errors. For example, if one logical partition reports an error for a shared resource, such as a managed system power supply, other active logical partitions might report the same error. By using the Manage Serviceable Events task in the HMC, you can avoid long lists of repetitive call-home information by recognizing that these are repeated errors and consolidating them into one error. In addition, you can use the Manage Serviceable Events task to initiate service functions on systems and logical partitions, including the exchanging of parts, configuring connectivity, and managing dumps. The following functions are available through the Service Focal Point on the Hardware Management Console: Service Focal Point: – Managing serviceable events and service data – Managing service indicators Error Information: – OS Diagnostic – Service Processor – Service Focal Point LED Management menu Serviceable events analysis Repair and Verify: – Concurrent Maintenance – Deferred Maintenance – Immediate Maintenance Hot-Node Add, Hot-Node Repair, and Memory Upgrade FRU Replacement Managing firmware levels: – HMC
  • 174. 160 IBM Power 720 and 740: Technical Overview and Introduction – Server – Adapter – Concurrent Firmware updates Call Home/Customer Notification Virtualization I/O Topology view Generate dump Remote support (full access) Virtual operator panel Service Focal Point Lite on the Integrated Virtualization Manager The following functions are available through the Service Focal Point Lite on the Integrated Virtualization Manager: Service Focal Point-Lite: – Managing serviceable events and service data – Managing service indicators Call Home/Customer Notification (both not available yet) Error Information menu: – OS Diagnostic – Service Focal Point lite LED Management menu Managing firmware levels: – Server – Adapter Virtualization Generate dump (limited capability) Remote support (limited access) 4.4.2 IBM Power Systems firmware maintenance The IBM Power Systems Client-Managed Microcode is a methodology that enables you to manage and install microcode updates on Power Systems and associated I/O adapters. The system firmware consists of service processor microcode, Open Firmware microcode, SPCN microcode, and the POWER Hypervisor. The firmware and microcode can be downloaded and installed either from an HMC, from a running partition, or from USB port number one on the rear of a Power 720 and 740, if that system is not managed by an HMC. Power Systems has a permanent firmware boot side, or A side, and a temporary firmware boot side, or B side. New levels of firmware must be installed on the temporary side first in order to test the update’s compatibility with existing applications. When the new level of firmware has been approved, it can be copied to the permanent side.
  • 175. Chapter 4. Continuous availability and manageability 161 For access to the initial web pages that address this capability, see Support for IBM Systems web page: http://www.ibm.com/systems/support For Power Systems, select the Power link. Figure 4-7 shows an example. Figure 4-7 Support for Power servers web page Although the content under the Popular links section can change, click the Firmware and HMC updates link to go to the resources for keeping your system’s firmware current.
  • 176. 162 IBM Power 720 and 740: Technical Overview and Introduction If there is an HMC to manage the server, the HMC interface can be use to view the levels of server firmware and power subsystem firmware that are installed and are available to download and install. Each IBM Power Systems server has the following levels of server firmware and power subsystem firmware: Installed level: This level of server firmware or power subsystem firmware has been installed and will be installed into memory after the managed system is powered off and then powered on. It is installed on the temporary side of system firmware. Activated level: This level of server firmware or power subsystem firmware is active and running in memory. Accepted level: This level is the backup level of server or power subsystem firmware. You can return to this level of server or power subsystem firmware if you decide to remove the installed level. It is installed on the permanent side of system firmware. IBM provides the Concurrent Firmware Maintenance (CFM) function on selected Power Systems. This function supports applying nondisruptive system firmware service packs to the system concurrently (without requiring a reboot operation to activate changes). For systems that are not managed by an HMC, the installation of system firmware is always disruptive. The concurrent levels of system firmware can, on occasion, contain fixes that are known as deferred. These deferred fixes can be installed concurrently but are not activated until the next IPL. Deferred fixes, if any, will be identified in the “Firmware Update Descriptions” table of the firmware document. For deferred fixes within a service pack, only the fixes in the service pack that cannot be concurrently activated are deferred. Table 4-1 shows the file-naming convention for system firmware. Table 4-1 Firmware naming convention PPNNSSS_FFF_DDD PP Package identifier 01 - 02 - NN Platform & Class AL Low End AM Mid Range AS Blade Server AH High End AP Bulk Power for IH AB Bulk Power for High End SSS Release indicator FFF Current fixpack DDD Last disruptive fixpack
  • 177. Chapter 4. Continuous availability and manageability 163 The following example uses the convention: 01AL710_086 = POWER7 Entry Systems Firmware for 8233-E8B and 8236-E8B An installation is disruptive if the following statements are true: The release levels (SSS) of currently installed and new firmware differ. The service pack level (FFF) and the last disruptive service pack level (DDD) are equal in new firmware. Otherwise, an installation is concurrent if the service pack level (FFF) of the new firmware is higher than the service pack level currently installed on the system and the conditions for disruptive installation are not met. 4.4.3 Electronic Services and Electronic Service Agent IBM has transformed its delivery of hardware and software support services to help you achieve higher system availability. Electronic Services is a web-enabled solution that offers an exclusive, no-additional-charge enhancement to the service and support available for IBM servers. These services provide the opportunity for greater system availability with faster problem resolution and preemptive monitoring. The Electronic Services solution consists of two separate, but complementary, elements: Electronic Services news page The Electronic Services news page is a single Internet entry point that replaces the multiple entry points that are traditionally used to access IBM Internet services and support. The news page enables you to gain easier access to IBM resources for assistance in resolving technical problems. IBM Electronic Service Agent™ The Electronic Service Agent is software that resides on your server. It monitors events and transmits system inventory information to IBM on a periodic, client-defined timetable. The Electronic Service Agent automatically reports hardware problems to IBM. Early knowledge about potential problems enables IBM to deliver proactive service that can result in higher system availability and performance. In addition, information that is collected through the Service Agent is made available to IBM service support representatives when they help answer your questions or diagnose problems. Installation and use of IBM Electronic Service Agent for problem reporting enables IBM to provide better support and service for your IBM server. To learn how Electronic Services can work for you, visit: https://www.ibm.com/support/electronic/portal
  • 178. 164 IBM Power 720 and 740: Technical Overview and Introduction 4.5 Operating system support for RAS features Table 4-2 provides an overview of a number of features for continuous availability that are supported by the various operating systems running on the POWER7 processor-based systems. Table 4-2 Operating system support for RAS features RAS feature AIX 5.3 AIX 6.1 AIX 7.1 IBM i 6.1.1 IBM i 7.1 RHEL 5 SLES 10 SP 3 SLES 11 SP 1 System deallocation of failing components Dynamic Processor Deallocation         Dynamic Processor Sparing         Processor Instruction Retry         Alternate Processor Recovery         Partition Contained Checkstop         Persistent processor deallocation         GX++ bus persistent deallocation      - -  PCI bus extended error detection         PCI bus extended error recovery      Most Mos t Mos t PCI-PCI bridge extended error handling      - - - Redundant RIO or 12x Channel link         PCI card hot-swap         Dynamic SP failover at run-time         Memory sparing with CoD at IPL time         Clock failover runtime or IPL         Memory availability 64-byte ECC code         Hardware scrubbing         CRC         Chipkill         L1 instruction and data array protection         L2/L3 ECC & cache line delete         Special uncorrectable error handling         Fault detection and isolation Platform FFDC diagnostics         Run-time diagnostics      Most Mos t Mos t
  • 179. Chapter 4. Continuous availability and manageability 165 Storage Protection Keys -     - - - Dynamic Trace      - -  Operating System FFDC -     - - - Error log analysis         Service Processor support for: Built-in-Self-Tests (BIST) for logic and arrays         Wire tests         Component initialization         Serviceability Boot-time progress indicators      Most Mos t Mos t Firmware error codes         Operating system error codes      Most Mos t Mos t Inventory collection         Environmental and power warnings         Hot-plug fans, power supplies         Extended error data collection         SP “call home” on non-HMC configurations         I/O drawer redundant connections         I/O drawer hot add and concurrent repair         Concurrent RIO/GX adapter add         Concurrent cold-repair of GX adapter         Concurrent add of powered I/O rack to Power 795         SP mutual surveillance w/ POWER Hypervisor         Dynamic firmware update with HMC         Service Agent Call Home Application         Guiding light LEDs         Lightpath LEDs         System dump for memory, POWER Hypervisor, SP         Infocenter / Systems Support Site service publications         System Support Site education         Operating system error reporting to HMC SFP         RMC secure error transmission subsystem         RAS feature AIX 5.3 AIX 6.1 AIX 7.1 IBM i 6.1.1 IBM i 7.1 RHEL 5 SLES 10 SP 3 SLES 11 SP 1
  • 180. 166 IBM Power 720 and 740: Technical Overview and Introduction Health check scheduled operations with HMC         Operator panel (real or virtual)         Concurrent operator panel maintenance         Redundant HMCs         Automated server recovery/restart         High availability clustering support         Repair and Verify Guided Maintenance      Most Mos t Mos t Concurrent kernel update -     - - - RAS feature AIX 5.3 AIX 6.1 AIX 7.1 IBM i 6.1.1 IBM i 7.1 RHEL 5 SLES 10 SP 3 SLES 11 SP 1
  • 181. © Copyright IBM Corp. 2010. All rights reserved. 167 Related publications The publications listed in this section are considered particularly suitable for a more detailed discussion of the topics covered in this paper. IBM Redbooks For information about ordering these publications, see “How to get Redbooks publications” on page 169. Note that some of the documents referenced here might be available in softcopy only. IBM Power 710 and 730 Technical Overview and Introduction, REDP-4637 IBM Power 795 Technical Overview and Introduction, REDP-4640 PowerVM Virtualization on IBM System p: Introduction and Configuration Fourth Edition, SG24-7940 IBM PowerVM Virtualization Managing and Monitoring, SG24-7590 IBM PowerVM Live Partition Mobility, SG24-7460 IBM System p Advanced POWER Virtualization (PowerVM) Best Practices, REDP-4194 PowerVM Migration from Physical to Virtual Storage, SG24-7825 IBM System Storage DS8000: Copy Services in Open Environments, SG24-6788 IBM System Storage DS8700 Architecture and Implementation, SG24-8786 PowerVM and SAN Copy Services, REDP-4610 SAN Volume Controller V4.3.0 Advanced Copy Services, SG24-7574 Other publications These publications are also relevant as further information sources: IBM Power Systems Facts and Features POWER7 Blades and Servers: ftp://public.dhe.ibm.com/common/ssi/ecm/en/pob03022usen/POB03022USEN.PDF PCI adapter placement for the 8202-E4B or 8205-E6B: http://publib.boulder.ibm.com/infocenter/powersys/v3r1m5/topic/p7eab/p7eab_72x_ 74x.pdf Specific storage devices supported for Virtual I/O Server, see: http://www14.software.ibm.com/webapp/set2/sas/f/vios/documentation/datasheet.ht ml IBM Power 710 server Data Sheet: ftp://public.dhe.ibm.com/common/ssi/ecm/en/pod03048usen/POD03048USEN.PDF IBM Power 720 server Data Sheet: ftp://public.dhe.ibm.com/common/ssi/ecm/en/pod03049usen/POD03049USEN.PDF
  • 182. 168 IBM Power 720 and 740: Technical Overview and Introduction IBM Power 730 server Data Sheet: ftp://public.dhe.ibm.com/common/ssi/ecm/en/pod03050usen/POD03050USEN.PDF IBM Power 740 server Data Sheet: ftp://public.dhe.ibm.com/common/ssi/ecm/en/pod03051usen/POD03051USEN.PDF IBM Power 750 server Data Sheet: http://www.ibm.com/common/ssi/fcgi-bin/ssialias?infotype=PM&subtype=SP&appname= STGE_PO_PO_USEN&htmlfid=POD03034USEN&attachment=POD03034USEN.PDF IBM Power 755 server Data Sheet: http://www.ibm.com/common/ssi/fcgi-bin/ssialias?infotype=PM&subtype=SP&appname= STGE_PO_PO_USEN&htmlfid=POD03035USEN&attachment=POD03035USEN.PDF IBM Power 770 server Data Sheet: http://www.ibm.com/common/ssi/fcgi-bin/ssialias?infotype=PM&subtype=SP&appname= STGE_PO_PO_USEN&htmlfid=POD03031USEN&attachment=POD03031USEN.PDF IBM Power 780 server Data Sheet: http://www.ibm.com/common/ssi/fcgi-bin/ssialias?infotype=PM&subtype=SP&appname= STGE_PO_PO_USEN&htmlfid=POD03032USEN&attachment=POD03032USEN.PDF IBM Power 795 server Data Sheet: ftp://public.dhe.ibm.com/common/ssi/ecm/en/pod03053usen/POD03053USEN.PDF Active Memory Expansion: Overview and Usage Guide: http://www-03.ibm.com/systems/power/hardware/whitepapers/am_exp.html Migration combinations of processor compatibility modes for active Partition Mobility: http://publib.boulder.ibm.com/infocenter/powersys/v3r1m5/topic/p7hc3/iphc3pcmco mbosact.htm Advance Toolchain for Linux website: http://www.ibm.com/developerworks/wikis/display/hpccentral/How+to+use+Advance+T oolchain+for+Linux+on+POWER Online resources These websites are also relevant as further information sources: IBM Power Systems Hardware Information Center at: http://publib.boulder.ibm.com/infocenter/systems/scope/hw/index.jsp IBM System Planning Tool site at: http://www.ibm.com/systems/support/tools/systemplanningtool/ Download from the IBM Fix Central website: http://www.ibm.com/support/fixcentral/ Power Systems Capacity on Demand website: http://www.ibm.com/systems/power/hardware/cod/ Support for IBM Systems website: http://www.ibm.com/systems/support IBM Electronic Services portal: https://www.ibm.com/support/electronic/portal
  • 183. Related publications 169 IBM Storage website: http://www.ibm.com/systems/storage/ How to get Redbooks publications You can search for, view, or download Redbooks publications, Redpapers publications, Technotes, draft publications and Additional materials, as well as order hardcopy Redbooks publications, at this website: ibm.com/redbooks Help from IBM IBM Support and downloads: ibm.com/support IBM Global Services: ibm.com/services
  • 184. 170 IBM Power 720 and 740: Technical Overview and Introduction
  • 186. ® REDP-4637-00 INTERNATIONAL TECHNICAL SUPPORT ORGANIZATION BUILDING TECHNICAL INFORMATION BASED ON PRACTICAL EXPERIENCE IBM Redbooks are developed by the IBM International Technical Support Organization. Experts from IBM, Customers and Partners from around the world create timely technical information based on realistic scenarios. Specific recommendations are provided to help you implement IT solutions more effectively in your environment. For more information: ibm.com/redbooks Redpaper™ IBM Power 720 and 740 Technical Overview and Introduction Features the POWER7 processor providing advanced multi-core technology Reduced power requirements with power-saving functions Describes leading midrange performance This IBM Redpaper publication is a comprehensive guide covering the IBM Power 720 and Power 740 servers supporting AIX, IBM i, and Linux operating systems. The goal of this paper is to introduce the major innovative Power 720 and 740 offerings and their prominent functions, including these: The POWER7 processor available at frequencies of 3.0 GHz, 3.3 GHz, 3.55 GHz, and 3.7 GHz The specialized POWER7 Level 3 cache that provides greater bandwidth, capacity, and reliability The 1 Gb or 10 Gb Integrated Virtual Ethernet adapter, included with each server configuration, and providing native hardware virtualization PowerVM virtualization including PowerVM Live Partition Mobility and PowerVM Active Memory Sharing Active Memory Expansion that provides more usable memory than what is physically installed on the system EnergyScale technology that provides features such as power trending, power-saving, capping of power, and thermal measurement Professionals who want to acquire a better understanding of IBM Power Systems products can benefit from reading this paper. This paper expands the current set of IBM Power Systems documentation by providing a desktop reference that offers a detailed technical description of the Power 720 and Power 740 systems. This paper does not replace the latest marketing materials and configuration tools. It is intended as an additional source of information that, together with existing sources, can be used to enhance your knowledge of IBM server solutions. Back cover