SlideShare a Scribd company logo
5
Most read
6
Most read
7
Most read
Routine Analysis of 
Waste Water 
Quality Parameter 
NAMRATA JARIWALA, Lecturer 
CIVIL ENGINEERING DEPARTMENT 
S. V. NATIONAL INSTITUTE OF TECHNOLOGY, SURAT
Objective 
• Essential for an effective and economical waste 
management programme. 
• Helps in the choice of waste treatment methods 
• Helps in deciding the self purification capacity of 
natural bodies. 
• Helps in deciding the efficiency of various 
treatment units. 
• Monitoring the treatment plant.
Types of Analysis 
• Physical Analysis: Determine aesthetic quality. 
• Chemical Analysis: Determine the amount of 
chemical substances.
Points to be considered 
• Methods of examination 
• Expression of result 
• Sampling points 
• Sampling equipment and recording the 
reading
CHARACTERISTICS OF WASTEWATER 
Significant Parameters for 
Physical Characteristics Chemical Characteristics Biological Characteristics 
Solids – 
Total, Suspended and Dissolved, 
Volatile and Fixed or mineral solids 
Organic contents – 
BOD,COD, Fats, phenols 
surfactants, oil and grease, etc. 
Animals 
Colour Inorganic contents-alkalinity, 
chlorides, 
nitrogen, sulfur, phosphorous, heavy 
metals, 
pH, carbohydrates etc. 
Plants 
Odour Gases – oxygen, methane, hydrogen 
sulfide 
Protista 
Temperature & Turbidity Pathogenic organisms, Viruses
Physical Characteristic 
(1) COLOUR 
• Fresh sewages is grey in colour:- like soap solution. 
• As time passes it begins to get black. 
• The colour of industrial waste water depends upon the chemical processes 
used in the industries. 
(2) ODOUR 
• Normally fresh sewage is not offensive. 
• It starts to gets stale it begins to give offensive odour. 
• Elimination of odour has become major consideration in the design and 
operation of waste water collection, treatment and disposal facilities. 
(3) TEMPERATURE: 
• Generally higher than water supply. 
• As the temperature increases the viscosity and bacterial activity increases. 
• Solubility of gases in waste water decreases as increases in temperature. 
• D.O. content decreases which affects the aquatic life. 
• High temperature results the growth of the undesirable water plants in the 
receiving water.
Physical Characteristic 
(4) TURBIDITY 
• It is a measure of light emitting property of waste water. 
• The stronger or more concentrated sewage, the higher is its turbidity. 
• Turbidity can be determine either by turbidity rod or by jackson’s turbidity 
meter. 
(5) TOTAL SOLIDS 
• Sewage contains 99.9% of water and 0.1% of solids. 
• The total solid contains of waste water is define as all the matter that remains 
as a residue upon evaporation to 103 to 105 degree centigrade. 
• Total solids are of three types (i) Suspended solids (ii) Colloidal solids and 
(iii) Dissolved solids. 
• S.S. are those which can be filtered out on a filter paper. i.e. Non-filterable 
solids. 
• S.S. can be divided as settleable solid and Non-settleable solids. 
• The T.S. can be classified as fixed solids and volatile solids.
Chemical Characteristic 
(1) pH Value: 
• Generally fresh sewage is alkaline in nature. 
• The determination of pH is important since certain treatment methods depends 
on proper pH value. 
(2) Chlorides contents: 
• Chlorides are mineral salts and therefore are not affect biological action of 
sewage. 
• The chlorides contents can be measured by titrating the sample of waste water 
with standard AgNo3 using potassium chromate as a indicator. 
(3) Nitrogen Contents: 
• The presence of nitrogen in waste water indicates the presence of organic 
matter. 
• Nitrogen is essential for the growth of plants and animals. 
• Nitrogen data is require to evaluate the treatability of waste water by 
biological process.
Chemical Characteristic 
Nitrogen appears in the following different forms 
(i) Ammonia nitrogen or free nitrogen.- Indicate old sewage. 
(ii) Organic nitrogen 
(iii) Albuminoid nitrogen – Indicates easily decomposable nitrogen presents. 
(iv) Nitrites nitrogen – Partially decomposed organic matter. 
(v) Nitrate nitrogen – Indices presence of fully oxidize organic matter. 
(4) Oil and Grease: 
• Clogged pipes and filters in winter. 
• Interfere with biological action. 
• Not easily decomposed by bacteria so necessary to remove from waste 
water. 
(5) Surfactants: 
• Primary from synthetic detergent. 
• The contents is determine by measuring the colour change in standard 
solution of Methylene Bule dye. 
• This interference in aeration of waste water. 
• Now-a-days ABS is replace with LAS which is biodegradable
Chemical Characteristic 
(6) Toxic compounds:- Bio-assay test 
(7) Sulphates concentration:- Turbidity method 
(8) D.O. Test:- 
• D.O. is the amount of oxygen in the dissolve state. 
• D.O. can be determine by Wrinker’s methods. 
• The presence of D.O. in waste water is desirable for aquatic life and to 
prevent from odour problem.
Biochemical Oxygen Demand: 
Biochemical oxygen demand has been defined as the amount of oxygen required by the microorganisms 
(mainly bacteria) to stabilize the biodegradable organic matter under aerobic conditions. 
NOTE : As the oxygen consumed by the microorganisms is directly proportional to the amount of 
biodegradable organic content, the BOD parameter indirectly measures the organic content of the 
liquid. 
NOTE : BOD parameter does not provide information about the amount of non-biodegradable 
organic contents of the liquid waste. 
Based on the first order kinetics of oxygen consumption by the microorganisms for carbonaceous organic 
matter present in the wastewater, following equations are used to compute the values of ultimate BOD 
(L0) and BOD at any time t (Lt). 
Lt = L0e-k’t or Lt = L0 x 10-kt 
and yt = L0(1 - e-k’t) or yt = L0(1 - 10-kt) 
where Lt = BOD at any time t, mg/L L0 = ultimate BOD at time t = 0, mg/L 
K’ = BOD rate constant to the base e, d-1 
K = BOD rate constant to the base 10, d-1 
= k’/e =k’/2.3 (normally assumed as 0.1 at 20°C) 
yt = BOD exerted or used at any time t, mg/L
The temperature correction for BOD rate constant is done by using the following equation. 
KT = K20 θ(T – 20) 
Where KT = BOD rate constant at any temperature T° 
K20 = BOD rate constant at temperature 20° C 
θ = temperature coefficient factor (varies from 1.056 to 1.135) 
= 1.047 (normally assumed for temperature range of 20 to 30°C)
The presence of a sufficient concentration of dissolved oxygen is critical to maintaining 
the aquatic life and aesthetic quality of streams and lakes. Determining how organic 
matter affects the concentration of dissolved oxygen (DO) in a stream or lake is integral to 
water-quality management. 
The decay of organic matter in water is measured as biochemical oxygen demand. Oxygen 
demand is a measure of the amount of oxidizable substances in a water sample that can 
lower DO concentrations.
The test for biochemical oxygen demand (BOD) is a bioassay procedure that 
measures the oxygen consumed by bacteria from the decomposition of organic 
matter (Sawyer and McCarty, 1978). The change in DO concentration is measured 
over a given period of time in water samples at a specified temperature 
There are two stages of decomposition of organic matter in the BOD test: a 
carbonaceous stage and a nitrogenous stage. 
Figure : Biochemical oxygen demand curves: (A) typical carbonaceous-demand curve showing the oxidation of 
organic matter, and (B) typical carbonaceous- plus nitrogeneous-demand curve showing the oxidation of ammonia 
and nitrite. (Modified from Sawyer and McCarty, 1978.)
The carbonaceous stage, or first stage, represents that portion of oxygen demand 
involved in the conversion of organic carbon - to carbon dioxide. 
The nitrogenous stage, or second stage, represents a combined carbonaceous plus 
nitrogenous demand, when organic nitrogen, ammonia, and nitrite are converted to 
nitrate. Nitrogenous oxygen demand generally begins after about 6 days. 
For some sewage, especially discharge from wastewater treatment plants utilizing 
biological treatment processes, nitrification can occur in less than 5 days if ammonia, 
nitrite, and nitrifying bacteria are present. 
The standard oxidation (or incubation) test period for BOD is 5 days at 20 degrees 
Celsius (BOD5). The BOD5 value has been used and reported for many applications, 
most commonly to indicate the effects of sewage and other organic wastes on 
dissolved oxygen in surface waters. 
The 5-day value, however, represents only a portion of the total biochemical oxygen 
demand. Twenty days is considered, by convention, adequate time for a complete 
biochemical oxidation of organic matter in a water sample, but a 20-day test often is 
impractical when data are needed to address an immediate concern.
BOD TEST APPARATUS
Routine analysis of wastewaters quality parameters
Routine analysis of wastewaters quality parameters
Note that BOD results represent approximate stream oxygen demands because the laboratory 
environment does not reproduce ambient stream conditions such as temperature, sunlight, 
biological populations, and water movement. 
Chemical Oxygen Demand 
Chemical oxygen demand (COD) is a measure of the ability of chemical reactions to 
oxidize matter in an aqueous system. The results are expressed in terms of oxygen so that 
they can be compared directly to the results of biochemical oxygen demand (BOD) testing. 
The test is performed by adding a strong oxidizing solution of a dichromate salt (e.g. 
potassium dichromate, K2Cr2O7) to a sample, boiling the mixture on a refluxing apparatus 
for two hours, and then titrating the amount of dichromate remaining after the refluxing 
period, with ferrous ammonium sulfate (FAS), at a known normality, to reduce the 
remaining dichromate. 
Generally, the COD is larger than the BOD exerted over a five-day period (BOD5), but there 
are exceptions in which microbes of the BOD test can oxidize materials that the COD 
reagents cannot. 
For a raw, domestic wastewater, the COD/BOD5 ratio is in the area of 1.5-3.0. 
Higher ratios would indicate the presence of toxic, non- biodegradable or less readily 
biodegradable materials.
The COD test is commonly used because it is a relatively short-term, precise test with little 
interference. However, the spent solutions generated by the test are hazardous. The liquids are 
acidic, and contain chromium, silver, mercury, and perhaps other toxic materials in the sample 
tested. For this reason laboratories are doing fewer or smaller COD tests in which smaller 
amounts of the same reagents are used. 
COD/BOD ratio 
The ratio of COD to BOD can give an indication of the biodegradability of a wastewater. 
i) In domestic sewage which is known to be readily biodegradable and treated 
successfully world-wide using a variety of biological treatment methods, the COD/BOD 
ratio varies typically from 1.5: 2. 
Thus if the COD/BOD ratio of industrial wastewater is also < 2, this provides a good 
indication that the wastewater can be treated biologically. 
ii) If the COD/BOD ratio is high and generally >5:1 , this indicates that the wastewater is 
non biodegradable , toxicity or nutrient imbalance is present and thus will present 
problems if biological treatment selected. 
iii) If COD/BOD falls between 2 – 5 :1 then this is a gray area. A lot of industrial 
wastewaters fall into this category. Therefore, further studies are needed.
Routine analysis of wastewaters quality parameters

More Related Content

PPT
Activated Sludge Process and biological Wastewater treatment system
PPTX
09 chlorination
PDF
Activated sludge calculations with excel course
PDF
Activated sludge process
PPT
Waste Water Treatment
PDF
L 18 trickling filter
PPTX
Waster water treatment
PDF
L 10 neutralization
Activated Sludge Process and biological Wastewater treatment system
09 chlorination
Activated sludge calculations with excel course
Activated sludge process
Waste Water Treatment
L 18 trickling filter
Waster water treatment
L 10 neutralization

What's hot (20)

PPTX
Bod cod do waste water treartment
PPTX
suspended growth bio treatments - BOD and Nitrification
PPT
Primary and secondary wastewater treatment..
PPT
Microbial removal during sewage treatment
PPTX
Water sampling ppt
PDF
Lecture 13 - types and characterization of waste water
PPT
Waste Water Treatment
PPTX
Tertiary treatment
PPTX
Waste water treatment processes
PDF
L 24 Activated Sludge Process
PPTX
Charecteristics of wastewater
PPTX
Waste Water Treatment
PDF
L 4 characterization of industrial waste and sampling
PPT
Water quality parameters
PPTX
Secondary wastewater treatment
PDF
Domestic Waste water treatment
PPTX
Grit chambers
PPTX
Integrated solid waste management
PDF
L 2 effluent standards and stream standards
PPTX
Tertiary waste management ppt
Bod cod do waste water treartment
suspended growth bio treatments - BOD and Nitrification
Primary and secondary wastewater treatment..
Microbial removal during sewage treatment
Water sampling ppt
Lecture 13 - types and characterization of waste water
Waste Water Treatment
Tertiary treatment
Waste water treatment processes
L 24 Activated Sludge Process
Charecteristics of wastewater
Waste Water Treatment
L 4 characterization of industrial waste and sampling
Water quality parameters
Secondary wastewater treatment
Domestic Waste water treatment
Grit chambers
Integrated solid waste management
L 2 effluent standards and stream standards
Tertiary waste management ppt
Ad

Similar to Routine analysis of wastewaters quality parameters (20)

PPTX
Chapter 2.pptx
PPTX
CHAPTER 4 ppt for the students who are doing engineering in civil
PDF
unit-1.-Itroduction-to-wastewater-treatment.pdf
PPT
Chemical Characteristics of Wastewater
DOCX
Bod btl2 new
PDF
Waste_Water_testing[1].pdf
DOC
COD &BOD&TOC& DO
PDF
Microbiology of wastewater & Wastewater Treatment
PPT
8.water pollution
DOCX
Jmas09 n1 p1
PPTX
water and waste water quality, 5th semester 2020 - Copy.pptx
PPT
ESTIMATION OF CHARACTERSTICS OF WASTEWATER
DOCX
DATA LOGGING_BOD
PDF
PPTX
Bio componets proposalc14123361t
PPTX
abd.pptx
PPTX
LECTURE 2 CHARACTERISTICS OF SEWAGE.pptx
PPTX
2. water pollution
PDF
Lec_2_Wastewater-typescharacteristics.pdf
PPTX
L8- ESTIMATION OF ORGANIC CONTENT.pptx
Chapter 2.pptx
CHAPTER 4 ppt for the students who are doing engineering in civil
unit-1.-Itroduction-to-wastewater-treatment.pdf
Chemical Characteristics of Wastewater
Bod btl2 new
Waste_Water_testing[1].pdf
COD &BOD&TOC& DO
Microbiology of wastewater & Wastewater Treatment
8.water pollution
Jmas09 n1 p1
water and waste water quality, 5th semester 2020 - Copy.pptx
ESTIMATION OF CHARACTERSTICS OF WASTEWATER
DATA LOGGING_BOD
Bio componets proposalc14123361t
abd.pptx
LECTURE 2 CHARACTERISTICS OF SEWAGE.pptx
2. water pollution
Lec_2_Wastewater-typescharacteristics.pdf
L8- ESTIMATION OF ORGANIC CONTENT.pptx
Ad

More from Arvind Kumar (20)

PPSX
Solid waste management
PPSX
Wastewater treatment
PPSX
Solar photovoltaics
PPSX
Renewable energy sources
PPTX
Incineration biomedicalwaste
PPTX
Department profile
PPT
Unit operation
PPT
Treatment of industrial waste water biological remediation of cyanides
PPT
Treatment & disposal of waste water
PDF
Sttp ppt msp_overview_09-10-2009_zvpm
PPT
Scope of reuse of sewage for baroda city
PPT
Recent advances in new separation technology
PPT
R e a c t o r s & its kinetics
PPT
Phytoremediation, an option for tertiary treatment of sewage
PPT
Need of tertiary treatment for anaerobic wastewater treatment
PPT
Ecological sanitation udd toilet
PPT
Concept of cetp
PPT
Comparative study of cyclic activated sludge and conventional activated sludg...
PPT
Ceia cdm workshop
PPT
Biological wastewater treatment processes
Solid waste management
Wastewater treatment
Solar photovoltaics
Renewable energy sources
Incineration biomedicalwaste
Department profile
Unit operation
Treatment of industrial waste water biological remediation of cyanides
Treatment & disposal of waste water
Sttp ppt msp_overview_09-10-2009_zvpm
Scope of reuse of sewage for baroda city
Recent advances in new separation technology
R e a c t o r s & its kinetics
Phytoremediation, an option for tertiary treatment of sewage
Need of tertiary treatment for anaerobic wastewater treatment
Ecological sanitation udd toilet
Concept of cetp
Comparative study of cyclic activated sludge and conventional activated sludg...
Ceia cdm workshop
Biological wastewater treatment processes

Recently uploaded (20)

PDF
RMMM.pdf make it easy to upload and study
PPTX
Microbial diseases, their pathogenesis and prophylaxis
PPTX
PPH.pptx obstetrics and gynecology in nursing
PDF
Business Ethics Teaching Materials for college
PDF
3rd Neelam Sanjeevareddy Memorial Lecture.pdf
PPTX
master seminar digital applications in india
PDF
Insiders guide to clinical Medicine.pdf
PDF
STATICS OF THE RIGID BODIES Hibbelers.pdf
PPTX
The Healthy Child – Unit II | Child Health Nursing I | B.Sc Nursing 5th Semester
PPTX
Cell Structure & Organelles in detailed.
PDF
Saundersa Comprehensive Review for the NCLEX-RN Examination.pdf
PPTX
school management -TNTEU- B.Ed., Semester II Unit 1.pptx
PPTX
BOWEL ELIMINATION FACTORS AFFECTING AND TYPES
PDF
Supply Chain Operations Speaking Notes -ICLT Program
PPTX
Cell Types and Its function , kingdom of life
PDF
2.FourierTransform-ShortQuestionswithAnswers.pdf
PDF
Module 4: Burden of Disease Tutorial Slides S2 2025
PDF
Origin of periodic table-Mendeleev’s Periodic-Modern Periodic table
PDF
Basic Mud Logging Guide for educational purpose
PDF
Mark Klimek Lecture Notes_240423 revision books _173037.pdf
RMMM.pdf make it easy to upload and study
Microbial diseases, their pathogenesis and prophylaxis
PPH.pptx obstetrics and gynecology in nursing
Business Ethics Teaching Materials for college
3rd Neelam Sanjeevareddy Memorial Lecture.pdf
master seminar digital applications in india
Insiders guide to clinical Medicine.pdf
STATICS OF THE RIGID BODIES Hibbelers.pdf
The Healthy Child – Unit II | Child Health Nursing I | B.Sc Nursing 5th Semester
Cell Structure & Organelles in detailed.
Saundersa Comprehensive Review for the NCLEX-RN Examination.pdf
school management -TNTEU- B.Ed., Semester II Unit 1.pptx
BOWEL ELIMINATION FACTORS AFFECTING AND TYPES
Supply Chain Operations Speaking Notes -ICLT Program
Cell Types and Its function , kingdom of life
2.FourierTransform-ShortQuestionswithAnswers.pdf
Module 4: Burden of Disease Tutorial Slides S2 2025
Origin of periodic table-Mendeleev’s Periodic-Modern Periodic table
Basic Mud Logging Guide for educational purpose
Mark Klimek Lecture Notes_240423 revision books _173037.pdf

Routine analysis of wastewaters quality parameters

  • 1. Routine Analysis of Waste Water Quality Parameter NAMRATA JARIWALA, Lecturer CIVIL ENGINEERING DEPARTMENT S. V. NATIONAL INSTITUTE OF TECHNOLOGY, SURAT
  • 2. Objective • Essential for an effective and economical waste management programme. • Helps in the choice of waste treatment methods • Helps in deciding the self purification capacity of natural bodies. • Helps in deciding the efficiency of various treatment units. • Monitoring the treatment plant.
  • 3. Types of Analysis • Physical Analysis: Determine aesthetic quality. • Chemical Analysis: Determine the amount of chemical substances.
  • 4. Points to be considered • Methods of examination • Expression of result • Sampling points • Sampling equipment and recording the reading
  • 5. CHARACTERISTICS OF WASTEWATER Significant Parameters for Physical Characteristics Chemical Characteristics Biological Characteristics Solids – Total, Suspended and Dissolved, Volatile and Fixed or mineral solids Organic contents – BOD,COD, Fats, phenols surfactants, oil and grease, etc. Animals Colour Inorganic contents-alkalinity, chlorides, nitrogen, sulfur, phosphorous, heavy metals, pH, carbohydrates etc. Plants Odour Gases – oxygen, methane, hydrogen sulfide Protista Temperature & Turbidity Pathogenic organisms, Viruses
  • 6. Physical Characteristic (1) COLOUR • Fresh sewages is grey in colour:- like soap solution. • As time passes it begins to get black. • The colour of industrial waste water depends upon the chemical processes used in the industries. (2) ODOUR • Normally fresh sewage is not offensive. • It starts to gets stale it begins to give offensive odour. • Elimination of odour has become major consideration in the design and operation of waste water collection, treatment and disposal facilities. (3) TEMPERATURE: • Generally higher than water supply. • As the temperature increases the viscosity and bacterial activity increases. • Solubility of gases in waste water decreases as increases in temperature. • D.O. content decreases which affects the aquatic life. • High temperature results the growth of the undesirable water plants in the receiving water.
  • 7. Physical Characteristic (4) TURBIDITY • It is a measure of light emitting property of waste water. • The stronger or more concentrated sewage, the higher is its turbidity. • Turbidity can be determine either by turbidity rod or by jackson’s turbidity meter. (5) TOTAL SOLIDS • Sewage contains 99.9% of water and 0.1% of solids. • The total solid contains of waste water is define as all the matter that remains as a residue upon evaporation to 103 to 105 degree centigrade. • Total solids are of three types (i) Suspended solids (ii) Colloidal solids and (iii) Dissolved solids. • S.S. are those which can be filtered out on a filter paper. i.e. Non-filterable solids. • S.S. can be divided as settleable solid and Non-settleable solids. • The T.S. can be classified as fixed solids and volatile solids.
  • 8. Chemical Characteristic (1) pH Value: • Generally fresh sewage is alkaline in nature. • The determination of pH is important since certain treatment methods depends on proper pH value. (2) Chlorides contents: • Chlorides are mineral salts and therefore are not affect biological action of sewage. • The chlorides contents can be measured by titrating the sample of waste water with standard AgNo3 using potassium chromate as a indicator. (3) Nitrogen Contents: • The presence of nitrogen in waste water indicates the presence of organic matter. • Nitrogen is essential for the growth of plants and animals. • Nitrogen data is require to evaluate the treatability of waste water by biological process.
  • 9. Chemical Characteristic Nitrogen appears in the following different forms (i) Ammonia nitrogen or free nitrogen.- Indicate old sewage. (ii) Organic nitrogen (iii) Albuminoid nitrogen – Indicates easily decomposable nitrogen presents. (iv) Nitrites nitrogen – Partially decomposed organic matter. (v) Nitrate nitrogen – Indices presence of fully oxidize organic matter. (4) Oil and Grease: • Clogged pipes and filters in winter. • Interfere with biological action. • Not easily decomposed by bacteria so necessary to remove from waste water. (5) Surfactants: • Primary from synthetic detergent. • The contents is determine by measuring the colour change in standard solution of Methylene Bule dye. • This interference in aeration of waste water. • Now-a-days ABS is replace with LAS which is biodegradable
  • 10. Chemical Characteristic (6) Toxic compounds:- Bio-assay test (7) Sulphates concentration:- Turbidity method (8) D.O. Test:- • D.O. is the amount of oxygen in the dissolve state. • D.O. can be determine by Wrinker’s methods. • The presence of D.O. in waste water is desirable for aquatic life and to prevent from odour problem.
  • 11. Biochemical Oxygen Demand: Biochemical oxygen demand has been defined as the amount of oxygen required by the microorganisms (mainly bacteria) to stabilize the biodegradable organic matter under aerobic conditions. NOTE : As the oxygen consumed by the microorganisms is directly proportional to the amount of biodegradable organic content, the BOD parameter indirectly measures the organic content of the liquid. NOTE : BOD parameter does not provide information about the amount of non-biodegradable organic contents of the liquid waste. Based on the first order kinetics of oxygen consumption by the microorganisms for carbonaceous organic matter present in the wastewater, following equations are used to compute the values of ultimate BOD (L0) and BOD at any time t (Lt). Lt = L0e-k’t or Lt = L0 x 10-kt and yt = L0(1 - e-k’t) or yt = L0(1 - 10-kt) where Lt = BOD at any time t, mg/L L0 = ultimate BOD at time t = 0, mg/L K’ = BOD rate constant to the base e, d-1 K = BOD rate constant to the base 10, d-1 = k’/e =k’/2.3 (normally assumed as 0.1 at 20°C) yt = BOD exerted or used at any time t, mg/L
  • 12. The temperature correction for BOD rate constant is done by using the following equation. KT = K20 θ(T – 20) Where KT = BOD rate constant at any temperature T° K20 = BOD rate constant at temperature 20° C θ = temperature coefficient factor (varies from 1.056 to 1.135) = 1.047 (normally assumed for temperature range of 20 to 30°C)
  • 13. The presence of a sufficient concentration of dissolved oxygen is critical to maintaining the aquatic life and aesthetic quality of streams and lakes. Determining how organic matter affects the concentration of dissolved oxygen (DO) in a stream or lake is integral to water-quality management. The decay of organic matter in water is measured as biochemical oxygen demand. Oxygen demand is a measure of the amount of oxidizable substances in a water sample that can lower DO concentrations.
  • 14. The test for biochemical oxygen demand (BOD) is a bioassay procedure that measures the oxygen consumed by bacteria from the decomposition of organic matter (Sawyer and McCarty, 1978). The change in DO concentration is measured over a given period of time in water samples at a specified temperature There are two stages of decomposition of organic matter in the BOD test: a carbonaceous stage and a nitrogenous stage. Figure : Biochemical oxygen demand curves: (A) typical carbonaceous-demand curve showing the oxidation of organic matter, and (B) typical carbonaceous- plus nitrogeneous-demand curve showing the oxidation of ammonia and nitrite. (Modified from Sawyer and McCarty, 1978.)
  • 15. The carbonaceous stage, or first stage, represents that portion of oxygen demand involved in the conversion of organic carbon - to carbon dioxide. The nitrogenous stage, or second stage, represents a combined carbonaceous plus nitrogenous demand, when organic nitrogen, ammonia, and nitrite are converted to nitrate. Nitrogenous oxygen demand generally begins after about 6 days. For some sewage, especially discharge from wastewater treatment plants utilizing biological treatment processes, nitrification can occur in less than 5 days if ammonia, nitrite, and nitrifying bacteria are present. The standard oxidation (or incubation) test period for BOD is 5 days at 20 degrees Celsius (BOD5). The BOD5 value has been used and reported for many applications, most commonly to indicate the effects of sewage and other organic wastes on dissolved oxygen in surface waters. The 5-day value, however, represents only a portion of the total biochemical oxygen demand. Twenty days is considered, by convention, adequate time for a complete biochemical oxidation of organic matter in a water sample, but a 20-day test often is impractical when data are needed to address an immediate concern.
  • 19. Note that BOD results represent approximate stream oxygen demands because the laboratory environment does not reproduce ambient stream conditions such as temperature, sunlight, biological populations, and water movement. Chemical Oxygen Demand Chemical oxygen demand (COD) is a measure of the ability of chemical reactions to oxidize matter in an aqueous system. The results are expressed in terms of oxygen so that they can be compared directly to the results of biochemical oxygen demand (BOD) testing. The test is performed by adding a strong oxidizing solution of a dichromate salt (e.g. potassium dichromate, K2Cr2O7) to a sample, boiling the mixture on a refluxing apparatus for two hours, and then titrating the amount of dichromate remaining after the refluxing period, with ferrous ammonium sulfate (FAS), at a known normality, to reduce the remaining dichromate. Generally, the COD is larger than the BOD exerted over a five-day period (BOD5), but there are exceptions in which microbes of the BOD test can oxidize materials that the COD reagents cannot. For a raw, domestic wastewater, the COD/BOD5 ratio is in the area of 1.5-3.0. Higher ratios would indicate the presence of toxic, non- biodegradable or less readily biodegradable materials.
  • 20. The COD test is commonly used because it is a relatively short-term, precise test with little interference. However, the spent solutions generated by the test are hazardous. The liquids are acidic, and contain chromium, silver, mercury, and perhaps other toxic materials in the sample tested. For this reason laboratories are doing fewer or smaller COD tests in which smaller amounts of the same reagents are used. COD/BOD ratio The ratio of COD to BOD can give an indication of the biodegradability of a wastewater. i) In domestic sewage which is known to be readily biodegradable and treated successfully world-wide using a variety of biological treatment methods, the COD/BOD ratio varies typically from 1.5: 2. Thus if the COD/BOD ratio of industrial wastewater is also < 2, this provides a good indication that the wastewater can be treated biologically. ii) If the COD/BOD ratio is high and generally >5:1 , this indicates that the wastewater is non biodegradable , toxicity or nutrient imbalance is present and thus will present problems if biological treatment selected. iii) If COD/BOD falls between 2 – 5 :1 then this is a gray area. A lot of industrial wastewaters fall into this category. Therefore, further studies are needed.