SlideShare a Scribd company logo
<Document Number> 
Copyright © Yokogawa Electric Corporation 
<date/time> 
- 1 - 
Miranda de Bruijn 
Product Manager Analytical BU 
Save 67 % on maintenance costs !
Why switch from Analog to Digital pH measurement ? 
Laboratory calibration automatically uploaded in Field instrumentation 
Moving intelligence closer measurement/control point 
Optimizing process control, simplifying maintenance 
Reducing configuration time by decreasing manual data entry 
Insensitive for environmental conditions 
preventive maintenance and predictive calibration 
Replace our analog sensors ?
Why switch from Analog to Digital pH measurement ? 
Reducing maintenance costs by 67% ! 
Put me through to Yokogawa !
Application : waste water pH control 
Installations : 6x measuring points 
Maintenance : 45 min per analog loop 
Frequency : twice per month 
Total time : 6x pH x 45 min 
4,5 hrs per month 
Application example : Analog sensor maintenance 
PROVE IT !
2 4 6 8 10 12 14 
1000 2000 3000 4000 500 0 6000 
1 
2 
3 
4 
5 
Time saved in Years 
Reduced Digital Sensor 
Calibration Expenses 
Analog Sensor Calibration Time (2xmonth) 
No of Sensors 
5 4 3 2 1 
€2000 Yr 
€4000 Yr 
€6000 Yr 
Hrs 
45 min 
30 min 
60 min 
4 Hrs 
2 Hrs 
Money saved in a year (€) 
3 Hrs
2 4 6 8 10 12 14 
1000 2000 3000 4000 500 0 6000 
1 
2 
3 
4 
5 
Time saved in Years 
Reduced Digital Sensor Calibration Expenses 
Analog Sensor Calibration Time 
(2x month) 
No. of Sensors 
5 
4 
3 
2 
1 
€2000 Yr 
€4000 Yr 
€6000 Yr 
Hrs 
45 min 
30 min 
60 min 
4 Hrs 
2 Hrs 
Money saved in a year (€) 
3 Hrs Analog Maintenance costs 
4,5 x 60€ = 270 € per month = 540 € per year = 6480 €
Application : waste water pH control 
Installations : 6x pH measuring points 
SENCOM : 15 min per digital loop 
Frequency : twice per month 
Total time : 6x pH x 15 min 
3 hrs per month 
PROVE IT ! 
Application example : Digital sensor maintenance
2 4 6 8 10 12 14 
2000 4000 6000 
1 
2 
3 
4 
5 
Reduced Digital Sensor 
Calibration Expenses 
Analog Sensor Calibration Time (2xmonth) 
No of Sensors 
5 
4 
3 
2 
1 
€2000 
€4000 
€5000 
Hrs 
45 min 
30 min 
60 min 
4 hrs 
2 hrs 
Money saved in a year (€) 
3 hrs SENCOM Maintenance costs 
3 hr x 60€ = 180 € costs per year = 2160 € 
Analog versus Digital 
€ 6480 versus € 2160 
Saving €4320 ! 
€3000
Why switch from Analog to Digital pH ? 
Put me through to Yokogawa ! 
Saving 67 % On maintenance costs
Start saving money today with SENCOM !
<Document Number> 
Copyright © Yokogawa Electric Corporation 
<date/time> 
- 11 - 
LETS BUILD THE FUTURE TOGETHER 
WITH WINING TOGETHER

More Related Content

PDF
Digital Brix Refractometer by ACMAS Technologies Pvt Ltd.
PDF
Coffee Moisture Meter by ACMAS Technologies Pvt Ltd.
PDF
Orthophosphate Analyzer for Wastewater Monitoring | YSI IQ SensorNet Alyza
PDF
Bacharach eca450 print version
PDF
Datasheet Fluke 971. Hubungi PT. Siwali Swantika 021-45850618
PPT
Digital Equipments By Auro Electronics India Pvt. Ltd, Ambala
PDF
Coir Moisture Meter by ACMAS Technologies Pvt Ltd.
PDF
Miri GA Mini Gas Validation Unit for IVF applications
Digital Brix Refractometer by ACMAS Technologies Pvt Ltd.
Coffee Moisture Meter by ACMAS Technologies Pvt Ltd.
Orthophosphate Analyzer for Wastewater Monitoring | YSI IQ SensorNet Alyza
Bacharach eca450 print version
Datasheet Fluke 971. Hubungi PT. Siwali Swantika 021-45850618
Digital Equipments By Auro Electronics India Pvt. Ltd, Ambala
Coir Moisture Meter by ACMAS Technologies Pvt Ltd.
Miri GA Mini Gas Validation Unit for IVF applications

Viewers also liked (13)

PDF
Whitepaper | Network Security - How to defend your Plant against the threats ...
PDF
VigilantPlant | excellence in Safety & Availability
PDF
Interview with the President | Annual Rapport 2014 Yokogawa
PDF
Energy management solutions. A Framework for your Energy Management System
PDF
Smartdac+ | Data Acquisition & Control
PDF
Whitepaper: The Next Evolution of Yokogawa CENTUM
PDF
Yokogawa in the LNG supply chain | VigilantPlant
PDF
Chemical Industry Solutions
PDF
Sustainable Energy Solutions for reducing CO2 emissions | VigilantPlant
PDF
Yokogawa's Vigilant Plant | Success Stories | Oil & Gas Industry
PDF
Yokogawa in the Water Industry | VigilantPlant
PDF
Yokogawa's Vigilant Plant | Success Stories | (petro)chemical industry
PDF
Centum VP - Evolution of Yokogawa System Solutions (2014)
Whitepaper | Network Security - How to defend your Plant against the threats ...
VigilantPlant | excellence in Safety & Availability
Interview with the President | Annual Rapport 2014 Yokogawa
Energy management solutions. A Framework for your Energy Management System
Smartdac+ | Data Acquisition & Control
Whitepaper: The Next Evolution of Yokogawa CENTUM
Yokogawa in the LNG supply chain | VigilantPlant
Chemical Industry Solutions
Sustainable Energy Solutions for reducing CO2 emissions | VigilantPlant
Yokogawa's Vigilant Plant | Success Stories | Oil & Gas Industry
Yokogawa in the Water Industry | VigilantPlant
Yokogawa's Vigilant Plant | Success Stories | (petro)chemical industry
Centum VP - Evolution of Yokogawa System Solutions (2014)
Ad

More from Yokogawa (17)

PDF
Senstation pH/ORP Measurement Solution - A scalable, integrated system that i...
PDF
TDLS8000 Tunable Diode Laser Spectrometer
PDF
Secured Remote Solutions for Critical Plant Assets
PDF
Application guide: improve (hydrogen) permeation resistance
PDF
CENTUM VP - 2014 version
PDF
EP-Analytics Energy Performance Analytics
PDF
Yokogawa's approach to renewable energy and community energy systems | annual...
PDF
Company profile: Yokogawa Marex (industrial software)
PDF
25% korting op Smartdac+
PDF
FieldMate - Versatile Device Management Wizard
PPT
Touring the Building | Yokogawa Europe HQ
PDF
Users Conference 2014 | Yokogawa Europe
PDF
The new YPY chairman
PDF
Petro IndustryNews | 'Full redundant field wireless automation solutions base...
PDF
Brochure of Yokogawa's Fast/Tools Supervisory Systems
PDF
Yokogawa in the Petrochemical Industry | VigilantPlant
PDF
Yokogawa in the Oil & Gas industry | Vigilant Plant
Senstation pH/ORP Measurement Solution - A scalable, integrated system that i...
TDLS8000 Tunable Diode Laser Spectrometer
Secured Remote Solutions for Critical Plant Assets
Application guide: improve (hydrogen) permeation resistance
CENTUM VP - 2014 version
EP-Analytics Energy Performance Analytics
Yokogawa's approach to renewable energy and community energy systems | annual...
Company profile: Yokogawa Marex (industrial software)
25% korting op Smartdac+
FieldMate - Versatile Device Management Wizard
Touring the Building | Yokogawa Europe HQ
Users Conference 2014 | Yokogawa Europe
The new YPY chairman
Petro IndustryNews | 'Full redundant field wireless automation solutions base...
Brochure of Yokogawa's Fast/Tools Supervisory Systems
Yokogawa in the Petrochemical Industry | VigilantPlant
Yokogawa in the Oil & Gas industry | Vigilant Plant
Ad

Sencom: save 67% on maitenance costs

  • 1. <Document Number> Copyright © Yokogawa Electric Corporation <date/time> - 1 - Miranda de Bruijn Product Manager Analytical BU Save 67 % on maintenance costs !
  • 2. Why switch from Analog to Digital pH measurement ? Laboratory calibration automatically uploaded in Field instrumentation Moving intelligence closer measurement/control point Optimizing process control, simplifying maintenance Reducing configuration time by decreasing manual data entry Insensitive for environmental conditions preventive maintenance and predictive calibration Replace our analog sensors ?
  • 3. Why switch from Analog to Digital pH measurement ? Reducing maintenance costs by 67% ! Put me through to Yokogawa !
  • 4. Application : waste water pH control Installations : 6x measuring points Maintenance : 45 min per analog loop Frequency : twice per month Total time : 6x pH x 45 min 4,5 hrs per month Application example : Analog sensor maintenance PROVE IT !
  • 5. 2 4 6 8 10 12 14 1000 2000 3000 4000 500 0 6000 1 2 3 4 5 Time saved in Years Reduced Digital Sensor Calibration Expenses Analog Sensor Calibration Time (2xmonth) No of Sensors 5 4 3 2 1 €2000 Yr €4000 Yr €6000 Yr Hrs 45 min 30 min 60 min 4 Hrs 2 Hrs Money saved in a year (€) 3 Hrs
  • 6. 2 4 6 8 10 12 14 1000 2000 3000 4000 500 0 6000 1 2 3 4 5 Time saved in Years Reduced Digital Sensor Calibration Expenses Analog Sensor Calibration Time (2x month) No. of Sensors 5 4 3 2 1 €2000 Yr €4000 Yr €6000 Yr Hrs 45 min 30 min 60 min 4 Hrs 2 Hrs Money saved in a year (€) 3 Hrs Analog Maintenance costs 4,5 x 60€ = 270 € per month = 540 € per year = 6480 €
  • 7. Application : waste water pH control Installations : 6x pH measuring points SENCOM : 15 min per digital loop Frequency : twice per month Total time : 6x pH x 15 min 3 hrs per month PROVE IT ! Application example : Digital sensor maintenance
  • 8. 2 4 6 8 10 12 14 2000 4000 6000 1 2 3 4 5 Reduced Digital Sensor Calibration Expenses Analog Sensor Calibration Time (2xmonth) No of Sensors 5 4 3 2 1 €2000 €4000 €5000 Hrs 45 min 30 min 60 min 4 hrs 2 hrs Money saved in a year (€) 3 hrs SENCOM Maintenance costs 3 hr x 60€ = 180 € costs per year = 2160 € Analog versus Digital € 6480 versus € 2160 Saving €4320 ! €3000
  • 9. Why switch from Analog to Digital pH ? Put me through to Yokogawa ! Saving 67 % On maintenance costs
  • 10. Start saving money today with SENCOM !
  • 11. <Document Number> Copyright © Yokogawa Electric Corporation <date/time> - 11 - LETS BUILD THE FUTURE TOGETHER WITH WINING TOGETHER