5796 and 7314-G30 expansion units Sundance-IB
7314 Dual 5796 I/O Unit Enclosure 19-inch Rack Mounting Hardware
The #7314 provides the mounting hardware required to install a #5796 PCI-DDR 12X Expansion Drawer in a
#0551, #0553, #0554 or #0555 19-inch rack. The enclosure can accommodate two #5796 drawers, side by
side, but it may also be used with only one #5796 drawer installed.
4 EIA units of rack space are required in a #0551, #0553, #0554 or #0555 rack.
The #7314 has rails adjustable to 29.25 inches depth.
Supported on Model 570 (POWER6).
The #7314 is a Customer Install Feature.
For System i POWER6 model 570 models, the only supported I/O drawer supporting 12X loop attachment is
the #5796 12X I/O Drawer. Two #5796 drawers can be enclosed in a #7314 enclosure. Key characteristics
of the #5796 include:
– 6 high speed, PCI-X DDR slots per #5796
– Dual mode or IOP-less IOAs only (no IOP support)
Picture shows two #5796s in a #7314 enclosure
Levko Fattori IBM Slovenia 3
Location code Description
C1, C2, C3, C4, C5, and C6 PCI slots. See also “PCI slot descriptions” on page 16
. C7-T1 and C7-T2 InfiniBand 12X connectors.
C8-T1 and C8-T2 Dual port SPCN connectors.
E1 and E2 Power supply connectors.
http://w3-03.ibm.com/support/techdocs/atsmastr.nsf/WebIndex/TD104011?Open
Levko Fattori IBM Slovenia 4
9406-MMA and IO drawer 7314-G30_SPCN connections - Power Control Loop
The cables lenghts chose in the diagram are for example only.
6006 SPCN 3m Cable
6007 SPCN 15 m Cable
6008 SPCN 6 m Cable
Levko Fattori IBM Slovenia 5
http://publib.boulder.ibm.com/infocenter/systems/scope/hw/index.jsp?topic=/iphau/partscables_external.htm
SPCN cable (3 meters) (System i5 and System p5 CIN 6006) 22R5239*
09P1251**
SPCN cable (15 meters) (System i5 CIN 1465, System i5 and System p5 CIN 6007) 22R5221*
21F9358**
SPCN cable (6 meters) (System p5 CIN 1464, System i5 and System p5 CIN 6008) 22R5219*
21F9469**
*
Designed to comply with RoHS requirement
**
Not designed to comply with RoHS requirement
Levko Fattori IBM Slovenia 6
H192246 : SPCN cable FC 6006 requirements on MMA
TEXT:
This tip resolves the confusion over the
requirement that multi-enclosure 9117 MMA
systems have an SPCN cable installed between the two Service
Interface cards located in the top 2 CEC enclosures. These cards are
also commonly referred to as FSP or Service Processor cards.
The SPCN cable completes the SPCN cable loop
when optional external I/O drawers or towers are connected.
Systems equipped with Firmware release 01EM320 or later will
automatically have Service Processor redundancy enabled, so both
FSPs must be included in the SPCN loop to allow either FSP to control
the external devices.
The IBM order system was recently updated to force
the inclusion of the SPCN cable between the FSP cards
in the top two enclosures regardless of whether the
order included external I/O drawers. This
configuration requirement insures that the cable is
already available or installed in the event that the
system configuration is changed to include external
I/O drawers. Orders for multi-enclosure systems
shipped prior to 2008 did not include the cable;
however, the order system will now automatically add
this cable when any MES activity is processed against
those systems.
From a functional perspective, this cable is NOT
required UNLESS external I/O drawers are present. The cable is NOT
Levko Fattori IBM Slovenia 7
required for Service Processor failover capability to be enabled or to
function correctly. However, if the cable is available, it should be
installed.
The following information is in the Sales Manual.
It is provided for reference.
Each p570 system with two or more CEC enclosures (eight
or more processor cores) that includes the attachment of
remote I/O drawers must have one Power Control Cable
(#6006 or similar) to connect the Service Interface Card
in the first enclosure to the Service Interface Card in
the second enclosure. In these configurations both
Service Interface Cards must be included in the Power
Control Cable loop.
(#6006) Power Control Cable (SPCN) - 3 meter
This feature provides a three-meter power control cable.
Attributes provided: 3M power control cable.
Attributes required: two drawers in the same rack.
For 9117-MMA: (#6006)
- Minimum required: 0
- Maximum allowed: no max (Initial order maximum: no max)
- OS level required: none
Initial Order/MES/Both/Supported: Both
CSU: Yes
Return parts MES: No
Note: Each system with two or more CEC enclosures requires one
SPCN cable to connect the Service Interface Card in the first
enclosure (uppermost enclosure in the stack) with the Service
Interface Card in the second enclosure.
SAS Keywords
Levko Fattori IBM Slovenia 8
#6446 12X Short Run 5796 Attach
The #6446 adapter provides the interface for attachment of the #5796 I/ O Drawer to a 12X Channel
loop.The adapter includes two 12X Channel connectors and is inserted into the #5796. This adapter does not
include the repeater function and is intended to support configurations where the host system and the
#5796 I/O drawers in the loop are located in the same rack.
The 12X cables attached to this adapter have the following restrictions. Cables between this adapter and a
host system cannot exceed 3.0 meters in length. Cables between two I/O drawers cannot exceed 1.5 meters
if both I/O drawers include this Short Run adapter feature #6446. Cables between two I/O drawers cannot
exceed 3.0 meters if either of the I/O drawers includes this Short Run adapter feature #6446. The
required 12X cables are ordered under a separate feature number. For longer cables, see the long run
adapter #6457.
There is a connecting rule for 12X cables and 12X adapters. For more information about this rule, see 4.13.1,
“System i POWER6 Model 570 I/O enhancements” on page 299.
Supported on Model 570 (POWER6).
The #6446 can be attached only #5796 I/O drawer.
The #6446 is a Customer Install Feature
#6457 12X Long Run 5796 Attach
The #6457 adapter provides the interface for attachment of the #5796 I/ O drawer to a 12X channel loop.
The adapter includes two 12X channel connectors and is inserted in the #5796. This adapter includes the
repeater function and can support longer cable loops allowing drawers to be located in adjacent racks. The
12X cables up to 8 meters in length can be attached to this adapter. The required 12X cables are ordered
under a separate feature number.
There is a connecting rule for 12X cables and 12X adapters. For more information about this rule, see 4.13.1,
“System i POWER6 Model 570 I/O enhancements” on page 299.
Supported on Model 570 (POWER6).
The #6457 can be attached only #5796 I/O drawer.
The #6457 is a Customer Install Feature.
Levko Fattori IBM Slovenia 9
Index
number
CCIN FC Part number Units per
assembly
Description
11 6457 520A 10N8782 sub
10N9312
1 12X Long Run 5796 Attach
11 6446 520B 10N774 sub
19N9311
1 12X Short Run 5796 Attach
11 520D 10N8867 1 SPCN card
11
11
Levko Fattori IBM Slovenia 10
FC6446 - 12X Short Run 5796 Attach
This adapter provides the interface for attachment of the FC5796 I/O Drawer to a 12X
Channel loop. The adapter includes two 12X Channel connectors and is inserted into the
FC5796. This adapter does not include the repeater function and is intended to support
configurations where the host system and the FC5796 I/O drawers in the loop are located
in the same rack.
12X cables attached to this adapter have the following restrictions. Cables between this
adapter and a host system may not exceed 3.5 Meters in length. Cables between two I/O
drawers may not exceed 1.5 Meters if both I/O drawers include this Short Run adapter
FC6446. Cables between two I/O Drawers may not exceed 3.5 Meters if either of the I/O
drawers includes this Short Run adapter FC6446.
FC6457 - 12X Long Run 5796 Attach
This adapter provides the interface for attachment of the FC5796 I/O drawer to a 12X
channel loop. The adapter includes two 12X channel connectors and is inserted in the
FC5796. This adapter includes the repeater function and can support longer cable loops
allowing drawers to be located in adjacent racks.
12X cables up to 8 meters in length can be attached to this adapter.
The required 12X cables are ordered under a separate feature number.
"R SR" is used to represent the Short Range option... No repeaters. This is also identified
by the lighter cream coloring of the cable retention guide.
"R LR" is used to represent the Long Range option... Repeaters. Also identified by the
darker olive green coloring of the cable retention guide.
All system (CEC) connections are labeled "R LR".
Levko Fattori IBM Slovenia 11
R SR designates RIO - Short Range R LR designates RIO - Long Range
Combination, Cream / Green
color connector, Short Range
(R SR)
Solid Green color connector,
Long Range (R LR)
Levko Fattori IBM Slovenia 12
If Drawers are in the same Rack as the system unit:
Cable length should be < 3.5 m
FC 6446 in Drawers will be ok.
Cables from drawer to drawer cannot be longer than 1.5m!
3.5M and you are ok with FC6446
Also drawer to drawer, if the drawers are together then you stay under 1.5 meter and
FC6446 is OK.
So if you daisy chain IO drawers that are all close together and you are in the same rack
as the 570 you
Levko Fattori IBM Slovenia 13
can use FC6446 on all.
IBM offers four 12X cable lengths
FC1829 0.6 meter
FC1830 1.5 meter
FC1840 3.0 meter
FC1834 8.0 meter
Cable feature Cable type Length Part number
1829 12x InfiniBand cable 0.6 m (2 ft.) 41V0226
1830 12x InfiniBand cable 1.5 m (5 ft.) 41V0227
1840 12x InfiniBand cable 3 m (9.8 ft.) 42V2132
1834 12x InfiniBand cable 8 m (26 ft.) 39J5642
Levko Fattori IBM Slovenia 14
Additional Method for recognize 12x, for case PMR: 27690,661,706.
In the HONE Intranet (http://ehone.ibm.com/), select Inventory Retrieval,
Select which inventory to retrieve:
Inventory type:
Hardware Software Both
Country: FRANCE
Machine type: 9406 AS400 / IBM eServer
* Serial number: 65FBFC1
And SUBMIT
Save File as 65FBFC1.CFR
Start e-config
Levko Fattori IBM Slovenia 15
Select machine 65FBFC1.CFR
After some time a CFR report is created
Diagram is created
Levko Fattori IBM Slovenia 16
By selecting of PROPOSED
Levko Fattori IBM Slovenia 17
From Configuration the Customer have 5796 Expansion Drawers ( 17 pieces ) and in the Drawer they have a
6457 12X Long Run attach.
At the page 9 You can see CCIN, FC and P/N
Additional method is from HSM
SYSTEM EXPANSION UNIT 5796-001 65-3734C LB12 U5796.001.653734C
SYSTEM BUS 520C 0D-8146037 LB13 07P6949 U5796.001.653734C
SYSTEM BUS 520C 0D-8146037 LB14 07P6949 U5796.001.653734C
SYSTEM BUS 520C 0D-8146037 LB15 07P6949 U5796.001.653734C
SYSTEM BUS 520C 0D-8146037 LB16 07P6949 U5796.001.653734C
SYSTEM BUS 520C 0D-8146037 LB17 07P6949 U5796.001.653734C
BACKPLANE 520C 0D-8146037 PCI11D 07P6949 U5796.001.653734C-P1
HSL I/O BRIDGE 520C 0D-8146037 BC15 07P6949 U5796.001.653734C-P1
BUS EXPANSION ADAPTER 520C 0D-8146037 BCC12 07P6949 U5796.001.653734C-P1
MULTI-ADAPTER BRIDGE 520C 0D-8146037 PCI12D 07P6949 U5796.001.653734C-P1
BUS EXPANSION ADAPTER 520C 0D-8146037 BCC13 07P6949 U5796.001.653734C-P1
MULTI-ADAPTER BRIDGE 520C 0D-8146037 PCI13D 07P6949 U5796.001.653734C-P1
BUS EXPANSION ADAPTER 520C 0D-8146037 BCC14 07P6949 U5796.001.653734C-P1
HSL I/O BRIDGE 520C 0D-8146037 BC16 07P6949 U5796.001.653734C-P1
MULTI-ADAPTER BRIDGE 520C 0D-8146037 PCI14D 07P6949 U5796.001.653734C-P1
BUS EXPANSION ADAPTER 520C 0D-8146037 BCC15 07P6949 U5796.001.653734C-P1
MULTI-ADAPTER BRIDGE 520C 0D-8146037 PCI15D 07P6949 U5796.001.653734C-P1
BUS EXPANSION ADAPTER 520C 0D-8146037 BCC16 07P6949 U5796.001.653734C-P1
MULTI-ADAPTER BRIDGE 520C 0D-8146037 PCI16D 07P6949 U5796.001.653734C-P1
BUS EXPANSION ADAPTER 520C 0D-8146037 BCC17 07P6949 U5796.001.653734C-P1
BUS EXPANSION ADAPTER 520A 1D-8037144 10N9312 U5796.001.653734C-P1-C7
SPCN CARD 520D 0D-8146171 10N8867 U5796.001.653734C-P1-C8
SYSTEM EXPANSION UNIT 5796-001 65-5129C LB06 U5796.001.655129C
SYSTEM BUS 520C 0D-8142140 LB07 07P6949 U5796.001.655129C
SYSTEM BUS 520C 0D-8142140 LB08 07P6949 U5796.001.655129C
SYSTEM BUS 520C 0D-8142140 LB09 07P6949 U5796.001.655129C
SYSTEM BUS 520C 0D-8142140 LB10 07P6949 U5796.001.655129C
SYSTEM BUS 520C 0D-8142140 LB11 07P6949 U5796.001.655129C
BACKPLANE 520C 0D-8142140 PCI05D 07P6949 U5796.001.655129C-P1
HSL I/O BRIDGE 520C 0D-8142140 BC09 07P6949 U5796.001.655129C-P1
BUS EXPANSION ADAPTER 520C 0D-8142140 BCC06 07P6949 U5796.001.655129C-P1
MULTI-ADAPTER BRIDGE 520C 0D-8142140 PCI06D 07P6949 U5796.001.655129C-P1
BUS EXPANSION ADAPTER 520C 0D-8142140 BCC07 07P6949 U5796.001.655129C-P1
MULTI-ADAPTER BRIDGE 520C 0D-8142140 PCI07D 07P6949 U5796.001.655129C-P1
BUS EXPANSION ADAPTER 520C 0D-8142140 BCC08 07P6949 U5796.001.655129C-P1
HSL I/O BRIDGE 520C 0D-8142140 BC10 07P6949 U5796.001.655129C-P1
MULTI-ADAPTER BRIDGE 520C 0D-8142140 PCI08D 07P6949 U5796.001.655129C-P1
BUS EXPANSION ADAPTER 520C 0D-8142140 BCC09 07P6949 U5796.001.655129C-P1
MULTI-ADAPTER BRIDGE 520C 0D-8142140 PCI09D 07P6949 U5796.001.655129C-P1
BUS EXPANSION ADAPTER 520C 0D-8142140 BCC10 07P6949 U5796.001.655129C-P1
MULTI-ADAPTER BRIDGE 520C 0D-8142140 PCI10D 07P6949 U5796.001.655129C-P1
BUS EXPANSION ADAPTER 520C 0D-8142140 BCC11 07P6949 U5796.001.655129C-P1
BUS EXPANSION ADAPTER 520A 1D-8037108 10N9312 U5796.001.655129C-P1-C7
SPCN CARD 520D 0D-8142012 10N8867 U5796.001.655129C-P1-C8
In a case You will found some mistake, please let me inform.
In a case You would like to add something, please send to me and I will update this book.
LevkoFattori
Thanks.

More Related Content

PDF
Introduction to BTRFS and ZFS
PPSX
Brocade Administration & troubleshooting
PPT
CCNA PPT
PDF
Ccna (200 125)
PPTX
Storage
PPTX
Ccna ppt1
PDF
OpenZFS novel algorithms: snapshots, space allocation, RAID-Z - Matt Ahrens
PPTX
Raid level
Introduction to BTRFS and ZFS
Brocade Administration & troubleshooting
CCNA PPT
Ccna (200 125)
Storage
Ccna ppt1
OpenZFS novel algorithms: snapshots, space allocation, RAID-Z - Matt Ahrens
Raid level

What's hot (20)

PPTX
AMBA 5 COHERENT HUB INTERFACE.pptx
PPTX
SOUG Oracle Unified Audit for Multitenant Databases
PPTX
Blu ray disc
PDF
Basic ccna interview questions and answers ~ sysnet notes
PDF
IBM Spectrum Scale for File and Object Storage
PDF
LinuxIO-Introduction-FUDCon-2015
PDF
ITN_Module_2_Basic_Switch_and_End_Device_Configuration.pdf.pdf
PPTX
Ibm spectrum scale fundamentals workshop for americas part 4 Replication, Str...
PDF
Intel's Out of the Box Network Developers Ireland Meetup on March 29 2017 - ...
PDF
HP C7000 Cconfiguration Guide v.10
PDF
Scaling paypal workloads with oracle rac ss
PPT
magnetic and optic based storage devices
PPT
Gpon omci v2__voice_configuration_introduction_omciv2_v2_pt_telkom
PPTX
IBM Spectrum Scale Secure- Secure Data in Motion and Rest
PPTX
Storage area network
PPTX
SAS vs SATA_ The Key Differences That You Should Know.pptx
PDF
CCNAv5 - S3: Chapter 7 EIGRP
PPTX
The Evolution of OpenStack – From Infancy to Enterprise
PDF
MAA Best Practices for Oracle Database 19c
PPTX
Troubleshooting and maintenance
AMBA 5 COHERENT HUB INTERFACE.pptx
SOUG Oracle Unified Audit for Multitenant Databases
Blu ray disc
Basic ccna interview questions and answers ~ sysnet notes
IBM Spectrum Scale for File and Object Storage
LinuxIO-Introduction-FUDCon-2015
ITN_Module_2_Basic_Switch_and_End_Device_Configuration.pdf.pdf
Ibm spectrum scale fundamentals workshop for americas part 4 Replication, Str...
Intel's Out of the Box Network Developers Ireland Meetup on March 29 2017 - ...
HP C7000 Cconfiguration Guide v.10
Scaling paypal workloads with oracle rac ss
magnetic and optic based storage devices
Gpon omci v2__voice_configuration_introduction_omciv2_v2_pt_telkom
IBM Spectrum Scale Secure- Secure Data in Motion and Rest
Storage area network
SAS vs SATA_ The Key Differences That You Should Know.pptx
CCNAv5 - S3: Chapter 7 EIGRP
The Evolution of OpenStack – From Infancy to Enterprise
MAA Best Practices for Oracle Database 19c
Troubleshooting and maintenance
Ad

Viewers also liked (17)

PDF
ADSA 2015
PDF
Swing Fore A Cure - Raffle table
PDF
Swing Fore A Cure
DOCX
Tim Johnston CV 2016
PPTX
Fort ad ppt
PDF
Davey- Pediatric HIV training Program at St Damien - 2015 - Received Feb 2nd ...
PPTX
What have you learnt about technologies from the
PDF
PPTX
Presentacion cuco
DOCX
LEXIRADIORESUME
ODP
iNVENTANDO HISTORIAS CON STORY CUBES
DOCX
Resume
PDF
Virtualização usando KVM e LXC
DOCX
First day of school for sixth grade
PPTX
DOCX
Obra comentarios
PDF
NBLCA_ CEO_Performance report_Dr.Dinakar
ADSA 2015
Swing Fore A Cure - Raffle table
Swing Fore A Cure
Tim Johnston CV 2016
Fort ad ppt
Davey- Pediatric HIV training Program at St Damien - 2015 - Received Feb 2nd ...
What have you learnt about technologies from the
Presentacion cuco
LEXIRADIORESUME
iNVENTANDO HISTORIAS CON STORY CUBES
Resume
Virtualização usando KVM e LXC
First day of school for sixth grade
Obra comentarios
NBLCA_ CEO_Performance report_Dr.Dinakar
Ad

Similar to SRC7314 5796 (20)

PDF
IBM Flex System Fabric SI4093 System Interconnect Module
PDF
IBM Flex System Storage Expansion Node
PDF
IBM Flex System Fabric EN4093 and EN4093R 10Gb Scalable Switches
PDF
can transceiber pca82c250/251 can transceiber AN96116[1].pdf
PDF
PDF
IBM Flex System Fabric CN4093 10Gb Converged Scalable Switch
PDF
IBM Flex System EN6132 2-port 40Gb Ethernet Adapter
PDF
Introduction to SCSI over FCP for Linux on System z
PDF
IBM Flex System FC3171 8Gb SAN Switch and Pass-thru
PDF
IBM Flex System Fabric EN4093 10Gb Scalable Switch
PDF
Ibm system storage ds3950 introduction redp4702
PDF
IBM Flex System Enterprise Chassis
PDF
PDF
IBM Flex System IB6132 2-port FDR InfiniBand Adapter
PDF
System X : Compatibility For Hardware, Applications, And Middleware
PDF
520com um001 -en-e
PDF
Manual guia power flex525
PDF
IBM Flex System FC5052 2-port and FC5054 4-port 16Gb FC Adapters
PPT
MPI Communication
PDF
Edgereadererw400 ds en
IBM Flex System Fabric SI4093 System Interconnect Module
IBM Flex System Storage Expansion Node
IBM Flex System Fabric EN4093 and EN4093R 10Gb Scalable Switches
can transceiber pca82c250/251 can transceiber AN96116[1].pdf
IBM Flex System Fabric CN4093 10Gb Converged Scalable Switch
IBM Flex System EN6132 2-port 40Gb Ethernet Adapter
Introduction to SCSI over FCP for Linux on System z
IBM Flex System FC3171 8Gb SAN Switch and Pass-thru
IBM Flex System Fabric EN4093 10Gb Scalable Switch
Ibm system storage ds3950 introduction redp4702
IBM Flex System Enterprise Chassis
IBM Flex System IB6132 2-port FDR InfiniBand Adapter
System X : Compatibility For Hardware, Applications, And Middleware
520com um001 -en-e
Manual guia power flex525
IBM Flex System FC5052 2-port and FC5054 4-port 16Gb FC Adapters
MPI Communication
Edgereadererw400 ds en

SRC7314 5796

  • 1. Levko Fattori IBM Slovenia 1
  • 2. Levko Fattori IBM Slovenia 2 5796 and 7314-G30 expansion units Sundance-IB 7314 Dual 5796 I/O Unit Enclosure 19-inch Rack Mounting Hardware The #7314 provides the mounting hardware required to install a #5796 PCI-DDR 12X Expansion Drawer in a #0551, #0553, #0554 or #0555 19-inch rack. The enclosure can accommodate two #5796 drawers, side by side, but it may also be used with only one #5796 drawer installed. 4 EIA units of rack space are required in a #0551, #0553, #0554 or #0555 rack. The #7314 has rails adjustable to 29.25 inches depth. Supported on Model 570 (POWER6). The #7314 is a Customer Install Feature. For System i POWER6 model 570 models, the only supported I/O drawer supporting 12X loop attachment is the #5796 12X I/O Drawer. Two #5796 drawers can be enclosed in a #7314 enclosure. Key characteristics of the #5796 include: – 6 high speed, PCI-X DDR slots per #5796 – Dual mode or IOP-less IOAs only (no IOP support) Picture shows two #5796s in a #7314 enclosure
  • 3. Levko Fattori IBM Slovenia 3 Location code Description C1, C2, C3, C4, C5, and C6 PCI slots. See also “PCI slot descriptions” on page 16 . C7-T1 and C7-T2 InfiniBand 12X connectors. C8-T1 and C8-T2 Dual port SPCN connectors. E1 and E2 Power supply connectors. http://w3-03.ibm.com/support/techdocs/atsmastr.nsf/WebIndex/TD104011?Open
  • 4. Levko Fattori IBM Slovenia 4 9406-MMA and IO drawer 7314-G30_SPCN connections - Power Control Loop The cables lenghts chose in the diagram are for example only. 6006 SPCN 3m Cable 6007 SPCN 15 m Cable 6008 SPCN 6 m Cable
  • 5. Levko Fattori IBM Slovenia 5 http://publib.boulder.ibm.com/infocenter/systems/scope/hw/index.jsp?topic=/iphau/partscables_external.htm SPCN cable (3 meters) (System i5 and System p5 CIN 6006) 22R5239* 09P1251** SPCN cable (15 meters) (System i5 CIN 1465, System i5 and System p5 CIN 6007) 22R5221* 21F9358** SPCN cable (6 meters) (System p5 CIN 1464, System i5 and System p5 CIN 6008) 22R5219* 21F9469** * Designed to comply with RoHS requirement ** Not designed to comply with RoHS requirement
  • 6. Levko Fattori IBM Slovenia 6 H192246 : SPCN cable FC 6006 requirements on MMA TEXT: This tip resolves the confusion over the requirement that multi-enclosure 9117 MMA systems have an SPCN cable installed between the two Service Interface cards located in the top 2 CEC enclosures. These cards are also commonly referred to as FSP or Service Processor cards. The SPCN cable completes the SPCN cable loop when optional external I/O drawers or towers are connected. Systems equipped with Firmware release 01EM320 or later will automatically have Service Processor redundancy enabled, so both FSPs must be included in the SPCN loop to allow either FSP to control the external devices. The IBM order system was recently updated to force the inclusion of the SPCN cable between the FSP cards in the top two enclosures regardless of whether the order included external I/O drawers. This configuration requirement insures that the cable is already available or installed in the event that the system configuration is changed to include external I/O drawers. Orders for multi-enclosure systems shipped prior to 2008 did not include the cable; however, the order system will now automatically add this cable when any MES activity is processed against those systems. From a functional perspective, this cable is NOT required UNLESS external I/O drawers are present. The cable is NOT
  • 7. Levko Fattori IBM Slovenia 7 required for Service Processor failover capability to be enabled or to function correctly. However, if the cable is available, it should be installed. The following information is in the Sales Manual. It is provided for reference. Each p570 system with two or more CEC enclosures (eight or more processor cores) that includes the attachment of remote I/O drawers must have one Power Control Cable (#6006 or similar) to connect the Service Interface Card in the first enclosure to the Service Interface Card in the second enclosure. In these configurations both Service Interface Cards must be included in the Power Control Cable loop. (#6006) Power Control Cable (SPCN) - 3 meter This feature provides a three-meter power control cable. Attributes provided: 3M power control cable. Attributes required: two drawers in the same rack. For 9117-MMA: (#6006) - Minimum required: 0 - Maximum allowed: no max (Initial order maximum: no max) - OS level required: none Initial Order/MES/Both/Supported: Both CSU: Yes Return parts MES: No Note: Each system with two or more CEC enclosures requires one SPCN cable to connect the Service Interface Card in the first enclosure (uppermost enclosure in the stack) with the Service Interface Card in the second enclosure. SAS Keywords
  • 8. Levko Fattori IBM Slovenia 8 #6446 12X Short Run 5796 Attach The #6446 adapter provides the interface for attachment of the #5796 I/ O Drawer to a 12X Channel loop.The adapter includes two 12X Channel connectors and is inserted into the #5796. This adapter does not include the repeater function and is intended to support configurations where the host system and the #5796 I/O drawers in the loop are located in the same rack. The 12X cables attached to this adapter have the following restrictions. Cables between this adapter and a host system cannot exceed 3.0 meters in length. Cables between two I/O drawers cannot exceed 1.5 meters if both I/O drawers include this Short Run adapter feature #6446. Cables between two I/O drawers cannot exceed 3.0 meters if either of the I/O drawers includes this Short Run adapter feature #6446. The required 12X cables are ordered under a separate feature number. For longer cables, see the long run adapter #6457. There is a connecting rule for 12X cables and 12X adapters. For more information about this rule, see 4.13.1, “System i POWER6 Model 570 I/O enhancements” on page 299. Supported on Model 570 (POWER6). The #6446 can be attached only #5796 I/O drawer. The #6446 is a Customer Install Feature #6457 12X Long Run 5796 Attach The #6457 adapter provides the interface for attachment of the #5796 I/ O drawer to a 12X channel loop. The adapter includes two 12X channel connectors and is inserted in the #5796. This adapter includes the repeater function and can support longer cable loops allowing drawers to be located in adjacent racks. The 12X cables up to 8 meters in length can be attached to this adapter. The required 12X cables are ordered under a separate feature number. There is a connecting rule for 12X cables and 12X adapters. For more information about this rule, see 4.13.1, “System i POWER6 Model 570 I/O enhancements” on page 299. Supported on Model 570 (POWER6). The #6457 can be attached only #5796 I/O drawer. The #6457 is a Customer Install Feature.
  • 9. Levko Fattori IBM Slovenia 9 Index number CCIN FC Part number Units per assembly Description 11 6457 520A 10N8782 sub 10N9312 1 12X Long Run 5796 Attach 11 6446 520B 10N774 sub 19N9311 1 12X Short Run 5796 Attach 11 520D 10N8867 1 SPCN card 11 11
  • 10. Levko Fattori IBM Slovenia 10 FC6446 - 12X Short Run 5796 Attach This adapter provides the interface for attachment of the FC5796 I/O Drawer to a 12X Channel loop. The adapter includes two 12X Channel connectors and is inserted into the FC5796. This adapter does not include the repeater function and is intended to support configurations where the host system and the FC5796 I/O drawers in the loop are located in the same rack. 12X cables attached to this adapter have the following restrictions. Cables between this adapter and a host system may not exceed 3.5 Meters in length. Cables between two I/O drawers may not exceed 1.5 Meters if both I/O drawers include this Short Run adapter FC6446. Cables between two I/O Drawers may not exceed 3.5 Meters if either of the I/O drawers includes this Short Run adapter FC6446. FC6457 - 12X Long Run 5796 Attach This adapter provides the interface for attachment of the FC5796 I/O drawer to a 12X channel loop. The adapter includes two 12X channel connectors and is inserted in the FC5796. This adapter includes the repeater function and can support longer cable loops allowing drawers to be located in adjacent racks. 12X cables up to 8 meters in length can be attached to this adapter. The required 12X cables are ordered under a separate feature number. "R SR" is used to represent the Short Range option... No repeaters. This is also identified by the lighter cream coloring of the cable retention guide. "R LR" is used to represent the Long Range option... Repeaters. Also identified by the darker olive green coloring of the cable retention guide. All system (CEC) connections are labeled "R LR".
  • 11. Levko Fattori IBM Slovenia 11 R SR designates RIO - Short Range R LR designates RIO - Long Range Combination, Cream / Green color connector, Short Range (R SR) Solid Green color connector, Long Range (R LR)
  • 12. Levko Fattori IBM Slovenia 12 If Drawers are in the same Rack as the system unit: Cable length should be < 3.5 m FC 6446 in Drawers will be ok. Cables from drawer to drawer cannot be longer than 1.5m! 3.5M and you are ok with FC6446 Also drawer to drawer, if the drawers are together then you stay under 1.5 meter and FC6446 is OK. So if you daisy chain IO drawers that are all close together and you are in the same rack as the 570 you
  • 13. Levko Fattori IBM Slovenia 13 can use FC6446 on all. IBM offers four 12X cable lengths FC1829 0.6 meter FC1830 1.5 meter FC1840 3.0 meter FC1834 8.0 meter Cable feature Cable type Length Part number 1829 12x InfiniBand cable 0.6 m (2 ft.) 41V0226 1830 12x InfiniBand cable 1.5 m (5 ft.) 41V0227 1840 12x InfiniBand cable 3 m (9.8 ft.) 42V2132 1834 12x InfiniBand cable 8 m (26 ft.) 39J5642
  • 14. Levko Fattori IBM Slovenia 14 Additional Method for recognize 12x, for case PMR: 27690,661,706. In the HONE Intranet (http://ehone.ibm.com/), select Inventory Retrieval, Select which inventory to retrieve: Inventory type: Hardware Software Both Country: FRANCE Machine type: 9406 AS400 / IBM eServer * Serial number: 65FBFC1 And SUBMIT Save File as 65FBFC1.CFR Start e-config
  • 15. Levko Fattori IBM Slovenia 15 Select machine 65FBFC1.CFR After some time a CFR report is created Diagram is created
  • 16. Levko Fattori IBM Slovenia 16 By selecting of PROPOSED
  • 17. Levko Fattori IBM Slovenia 17 From Configuration the Customer have 5796 Expansion Drawers ( 17 pieces ) and in the Drawer they have a 6457 12X Long Run attach. At the page 9 You can see CCIN, FC and P/N Additional method is from HSM SYSTEM EXPANSION UNIT 5796-001 65-3734C LB12 U5796.001.653734C SYSTEM BUS 520C 0D-8146037 LB13 07P6949 U5796.001.653734C SYSTEM BUS 520C 0D-8146037 LB14 07P6949 U5796.001.653734C SYSTEM BUS 520C 0D-8146037 LB15 07P6949 U5796.001.653734C SYSTEM BUS 520C 0D-8146037 LB16 07P6949 U5796.001.653734C SYSTEM BUS 520C 0D-8146037 LB17 07P6949 U5796.001.653734C BACKPLANE 520C 0D-8146037 PCI11D 07P6949 U5796.001.653734C-P1 HSL I/O BRIDGE 520C 0D-8146037 BC15 07P6949 U5796.001.653734C-P1 BUS EXPANSION ADAPTER 520C 0D-8146037 BCC12 07P6949 U5796.001.653734C-P1 MULTI-ADAPTER BRIDGE 520C 0D-8146037 PCI12D 07P6949 U5796.001.653734C-P1 BUS EXPANSION ADAPTER 520C 0D-8146037 BCC13 07P6949 U5796.001.653734C-P1 MULTI-ADAPTER BRIDGE 520C 0D-8146037 PCI13D 07P6949 U5796.001.653734C-P1 BUS EXPANSION ADAPTER 520C 0D-8146037 BCC14 07P6949 U5796.001.653734C-P1 HSL I/O BRIDGE 520C 0D-8146037 BC16 07P6949 U5796.001.653734C-P1 MULTI-ADAPTER BRIDGE 520C 0D-8146037 PCI14D 07P6949 U5796.001.653734C-P1 BUS EXPANSION ADAPTER 520C 0D-8146037 BCC15 07P6949 U5796.001.653734C-P1 MULTI-ADAPTER BRIDGE 520C 0D-8146037 PCI15D 07P6949 U5796.001.653734C-P1 BUS EXPANSION ADAPTER 520C 0D-8146037 BCC16 07P6949 U5796.001.653734C-P1 MULTI-ADAPTER BRIDGE 520C 0D-8146037 PCI16D 07P6949 U5796.001.653734C-P1 BUS EXPANSION ADAPTER 520C 0D-8146037 BCC17 07P6949 U5796.001.653734C-P1 BUS EXPANSION ADAPTER 520A 1D-8037144 10N9312 U5796.001.653734C-P1-C7 SPCN CARD 520D 0D-8146171 10N8867 U5796.001.653734C-P1-C8 SYSTEM EXPANSION UNIT 5796-001 65-5129C LB06 U5796.001.655129C SYSTEM BUS 520C 0D-8142140 LB07 07P6949 U5796.001.655129C SYSTEM BUS 520C 0D-8142140 LB08 07P6949 U5796.001.655129C SYSTEM BUS 520C 0D-8142140 LB09 07P6949 U5796.001.655129C SYSTEM BUS 520C 0D-8142140 LB10 07P6949 U5796.001.655129C SYSTEM BUS 520C 0D-8142140 LB11 07P6949 U5796.001.655129C BACKPLANE 520C 0D-8142140 PCI05D 07P6949 U5796.001.655129C-P1 HSL I/O BRIDGE 520C 0D-8142140 BC09 07P6949 U5796.001.655129C-P1 BUS EXPANSION ADAPTER 520C 0D-8142140 BCC06 07P6949 U5796.001.655129C-P1 MULTI-ADAPTER BRIDGE 520C 0D-8142140 PCI06D 07P6949 U5796.001.655129C-P1 BUS EXPANSION ADAPTER 520C 0D-8142140 BCC07 07P6949 U5796.001.655129C-P1 MULTI-ADAPTER BRIDGE 520C 0D-8142140 PCI07D 07P6949 U5796.001.655129C-P1 BUS EXPANSION ADAPTER 520C 0D-8142140 BCC08 07P6949 U5796.001.655129C-P1 HSL I/O BRIDGE 520C 0D-8142140 BC10 07P6949 U5796.001.655129C-P1 MULTI-ADAPTER BRIDGE 520C 0D-8142140 PCI08D 07P6949 U5796.001.655129C-P1 BUS EXPANSION ADAPTER 520C 0D-8142140 BCC09 07P6949 U5796.001.655129C-P1 MULTI-ADAPTER BRIDGE 520C 0D-8142140 PCI09D 07P6949 U5796.001.655129C-P1 BUS EXPANSION ADAPTER 520C 0D-8142140 BCC10 07P6949 U5796.001.655129C-P1 MULTI-ADAPTER BRIDGE 520C 0D-8142140 PCI10D 07P6949 U5796.001.655129C-P1 BUS EXPANSION ADAPTER 520C 0D-8142140 BCC11 07P6949 U5796.001.655129C-P1 BUS EXPANSION ADAPTER 520A 1D-8037108 10N9312 U5796.001.655129C-P1-C7 SPCN CARD 520D 0D-8142012 10N8867 U5796.001.655129C-P1-C8 In a case You will found some mistake, please let me inform. In a case You would like to add something, please send to me and I will update this book. LevkoFattori Thanks.