WTI RPB+
WTI RPB+
Remote Power Switch
_______________________________________
How to Buy
Call: 1-877-878-9134 for this product Email: sales@launch3.net Click to send an RFQ:
http://www.launch3telecom.com/wti/rpb.html
Part number: RPB+ Datasheets: https://www.launch3telecom.com/shared_
media/datasheet/rpbpguid.pdf
Manufacturer: WTI Weight: N/A
Title: Remote Power Switch Category: N/A
Description: Remote Power Switch Genre: N/A
Heci: N/A
Part Page URL:
About Us
Launch 3 Telecom is your one stop shop for all your Telecom and Data/Networking
Hardware needs and genuine WTI replacement parts. We have loyally served our
customers since 2003. Our product expertise, quality customer service, competitive pricing
-on items like this WTI RPB+ -- are a few of the reasons why more telecom professionals
buy from Launch 3 Telecom every day.
_______________________________________
Payment and Processing
We accept Visa, Mastercard, American Express and Paypal payments for this WTI RPB+. We
can also accept Purchase Orders for Net Terms upon approval. Launch 3 Telecom does have
a Government Cage Code so if this is for a Government purchase please tells us! You may
also call us at 877-878-9134 or email us at sales@launch3.net for our credit card form.
Please call us today to purchase this WTI RPB+ item while inventory and sale last.
Same Day Shipping, Order Confirmation and Order
Tracking
Once your order is placed for the WTI RPB+, you may select from several shipping
methods, including UPS, Federal Express, DHL, USPS, 3 day, 2 day, overnight and
international methods. Orders received and approved before 3PM EST will generally ship
the same business day. You will receive an order confirmation email for your WTI RPB+
along with the tracking number as soon as it is available. The tracking number will allow
you to track your shipment in real time. We pack the WTI RPB+ in anti-static bubble wrap
to ensure safe delivery. We will combine multiple items in one shipment whenever
possible to save on shipping time and costs. Because we have several distribution points
and vendor locations, sometimes orders will be divided into multiple shipments, but never
at extra cost to you.
_______________________________________
Warranty
Every item you purchase from us includes a warranty and our hassle-free return policy. We
stand by our product and your satisfaction is our goal. If you ever have questions or
concerns about your WTI RPB+ order, simply contact our Customer Service Department at
877-878-9134, Monday - Friday, 9 AM - 5 PM EST. Friendly customer service reps are
available to assist you with your order.
Services from Launch 3 Telecom
Launch 3 Telecom can also repair the WTI
RPB+, provides maintenance contracts, De-
installation, Telecom Consignment and
Recycling. Please contact Launch 3 Telecom to
learn more about these services! Launch 3
Telecom specializes in installation of all
telecom related systems. Our team is equipped
to handle all telecom equipment including
cellular, Fixed Wireless, WiMAX, Central Office,
and more. No project is too small or too big,
and each is handled by a dedicated telecom
professional.
De-Installation - Our Network Installation
Experts will properly de-install your equipment,
package it, and ship it to our warehouse for
storage.
Testing - Our team of technicians will inspect
each piece of equipment thoroughly. If a piece
of equipment needs repair, we’ll provide the
resources and technology to guarantee each
piece is ready to be sold.
Asset Recovery - We can store your equipment
in one of our expansive warehouses located
around the country until your equipment is
sold so you can save on storage costs and avoid
cluttering your equipment floor.
Repair Services - Launch 3 Telecom is your one-
stop solution to your entire Telecom
Equipment & System repair. Our team of
dedicated professionals will get your system
back up and running quickly and efficiently. We
repair cell sites, central office switching,
combiners, data networking, transmission,
power supplies, microwave, radios, IP Cameras,
Sonet /SHD, power, power amps, CDMA, GSM,
TDMA, and PBX Keyphone.
Third Party Logistics - If you are currently
operating a direct route or if you are interested
in setting one up, Launch 3 Telecom would like
to discuss the opportunity of sending you
traffic. Contact us today to speak to a Call
Termination Specialist for more details at
voip@launch3telecom.com
RPB+; Remote Power Boot Switch -- User's Guide WTI Part No.: 12651 Rev. B RPB+ Remote Power Boot Switch User's Guide 5 Sterling, Irvine,
California 92618-2517 USA U.S. & Canada: (800) 854-7226 Phone: (949) 586-9950 Fax: (949) 583-9515 www.wti.com Table of Contents q 1.
Introduction q 2. Unit Description r r q 2.1. Front Panel 2.2. Back Panel 3. Installation r 3.1. SetUp Switches r 3.2. Control Port Connection s
r q 3.3. Power Connection 4. Start-Up / Configuration r q 3.2.1. Connecting to a Modem 4.1. The Power-Up Default String 5. Operation
Appendices file:///C|/WEBPAGE/guides/rpbp/build/rpbpguid.htm (1 of 12) [3/9/2000 5:08:10 PM] _x000C_RPB+; Remote Power Boot Switch
-- User's Guide q A. Specifications q B. Customer Service List of Figures q 1. Front Panel q 2. Back Panel q 3. RS-232 (Control Port)
Interface Schematic q 4. RPB+ Cable Connections q 5. The Status Screen 1. Introduction Network equipment sometimes "locks-up", making
it impossible to communicate. The RPB+ Remote Power Boot Switch can switch AC power on 5 individually controlled plugs, allowing
attached equipment to reset (re-boot). ASCII commands are sent to the RS-232 Control Port to select plugs, and specify On, Off, or Boot
operations. A convenient Status Screen shows On/Off conditions at each plug. RPB+ features include a security password, Location I.D. field,
and plug labels to identify the device connected to each plug. Features: q Remotely Toggles AC Power to Five Separate Outlets. q Serial RS232
Control Port Interfaces Directly with a PC or External Modem, Allowing Local or Remote Control. q Status Display Shows Plug Labels and
On/Off Conditions. q Simple ASCII Commands for On, Off, or Boot (Off/On). q User-Selectable Re-Boot Cycle Duration (Off Time). q User-
Programmable Password Feature. q User-Programmable Location I.D. q User-Selectable Echo Mode. q User-Programmable Plug Labels. q
User-Programmable Power-Up Defaults. q Requires Only One Rack Space. q Available in 115 VAC or 230 VAC Configurations Typographic
Conventions file:///C|/WEBPAGE/guides/rpbp/build/rpbpguid.htm (2 of 12) [3/9/2000 5:08:10 PM] _x000C_RPB+; Remote Power Boot
Switch -- User's Guide Throughout this manual, typefaces and characters have been used to denote the following: COURIER FONT Indicates
characters typed on the keyboard. For example, /S or /3 ON. [Bold Font] Text set in bold face and enclosed in square brackets indicates a
specific key. For example, [Enter] or [Esc]. 2. Unit Description 2.1. Front Panel Figure 1: Front Panel As shown in Figure 1, the RPB+ front
panel includes a series of LED indicators which function as follows: 1. POWER ON: Lights when AC Power is applied to the RPB+. 2. DATA
INPUT: Flashes when ASCII commands are received at the Control Port. 3. PLUG ON (Plugs 1 - 5): Lights when the corresponding plug is
switched On. 2.2. Back Panel Figure 2: Back Panel As shown in Figure 2, the RPB+ back panel includes the following items:
file:///C|/WEBPAGE/guides/rpbp/build/rpbpguid.htm (3 of 12) [3/9/2000 5:08:10 PM] _x000C_RPB+; Remote Power Boot Switch -- User's
Guide 1. Switched AC Outlets (Plugs 1 - 5): For connection to up to five AC devices. Each outlet is capable of switching up to 15 Amps. The
total for all five outlets must not exceed 15 Amps. 2. SetUp Switches (RATE): A bank of four DIP Switches which set the Control Port baud rate,
select the Off Time duration, enable/disable the Password Option, and enable/disable the Read Only Mode. 3. RS232 (Control) Port: For
connection to an external modem or local PC. The RPB+ accepts ASCII commands via the Control Port. 4. DEFAULT Button: Reads Rate Switch
settings and sets parameters accordingly. This allows the user to change Rate Switch settings without re-booting the RPB+ and connected
devices. The Default Button can also be used to bypass the Password Prompt. 5. Power Cable (115 VAC Units) Power Cable Receptacle (230
VAC Units) 6. Circuit Breaker: 15 Amps 7. Power Switch 3. Installation 3.1. SetUp Switches The SetUp Switches select the baud rate and Off
Time, and enable/disable the Password feature and Read Only Mode. If switch settings are changed while the unit is powered On, press the
Default Button to re-read switches. The Default Button allows the user to change switch settings while power is on, without re-booting the
RPB+ and connected devices. Note: If Rate Switch
settings are changed while the unit is powered on, new parameters will not take effect until the Default Button is pressed, or the RPB+ is
powered Off and On. Off Time: When a boot cycle is initiated, the "Off Time" determines the length of time the device will remain off until
power is restored. Password: When enabled, a password is required in order to access the RPB+ Command Mode (Default = [Enter]). To re-
define the Password, refer to Section 4. Read Only Mode: When enabled, the /P command (Define Parameters) is suppressed. This
file:///C|/WEBPAGE/guides/rpbp/build/rpbpguid.htm (4 of 12) [3/9/2000 5:08:10 PM] _x000C_RPB+; Remote Power Boot Switch -- User's
Guide allows the user to invoke On/Off/Boot commands, but prevents redefinition of parameters such as the Password and Power-Up
Default. Switch Function Up Down 1 Control Port Baud Rate 2 Off Time 10 sec. 5 sec.* 3 Password Function Disable Enable* 4 Read
Only Mode Enable Disable* 2400 bps 9600 bps* * = Factory Setting 3.2. Control Port Connection The male, DB9 connector (labeled "RS232")
is used for connection to an external modem or local PC. The RS232 Port uses a DTE configuration, similar to an AT computer. Figure 3
describes the Control Port interface. Figure 3: RS-232 (Control Port) Interface Schematic 3.2.1. Connecting to a Modem When connecting
directly to an external modem, use a standard AT to Modem cable. Make certain the modem is initialized at the same baud rate as the RPB+
(SetUp Switch 1). The modem must be placed in Auto-Answer mode, and set to answer in one ring. Please refer to the user's guide for your
external modem in order to determine the appropriate AT command file:///C|/WEBPAGE/guides/rpbp/build/rpbpguid.htm (5 of 12)
[3/9/2000 5:08:10 PM] _x000C_RPB+; Remote Power Boot Switch -- User's Guide string. 3.3. Power Connection The Power Switch located on
the back panel must be "On" in order for the RPB+ to operate. Each time the unit is powered On, the five AC outlets will be switched On or
Off, as dictated by the Power-Up Default String (see Section 4.1). Each outlet is capable of switching up to 15 Amps of AC power. The total for
all 5 outlets cannot exceed 15 Amps. Figure 4: RPB+ Cable Connections 4. Start-Up / Configuration 1. Access the RPB+ Command Mode: The
RPB+ is transparent to parity and will accept 7 or 8 bit characters, but will always answer back at 8 bits, no parity. Make certain your
communications program (e.g. ProComm) is set for the appropriate baud rate, bits, and parity. It is also recommended to set the
communications program for TTY mode. . Via Modem: Start your communications program. Dial the external modem connected to the RPB+.
Wait for the Connect message and proceed to Step 2. b. Via Local PC: Start your communications program.
file:///C|/WEBPAGE/guides/rpbp/build/rpbpguid.htm (6 of 12) [3/9/2000 5:08:10 PM] _x000C_RPB+; Remote Power Boot Switch -- User's
Guide 2. Password: If the Password function is enabled, the unit will display a prompt. Key in the Password and press [Enter]. If the password
has not yet been defined, just press [Enter]. Note: q The Password feature is case sensitive. q If you forget your password, press the Default
Button when the Password Prompt appears, then invoke the /P command to display the Password. 3. The RPB+ will display the Status Screen
(Figure 5). Location: WESTERN TELEMATIC, INC. Default: 01110 Plug 1 2 3 4 5 Label PRINTER SERVER ONE SERVER TWO MODEM BANK FAX
Condition OFF ON ON ON OFF Command Summary: /S Status /P Enter Parameters /D Set Plugs to Default /X Exit To Switch /n s Where n =
Plug #, * = All, and s = ON/OFF/BOOT RPB+> Figure 5: The Status Screen 4. When the "RPB+>" prompt appears, type /P [Enter] to define
system parameters. The unit will display a series of prompts. Note: q RPB+ commands are not case sensitive. q To skip a prompt without
changing its current definition, press [Enter]. q To exit from the Define Parameters function, press [Esc] at any time. Parameters defined up to
that point will be saved. . Location: Key in a text string that describes the RPB+ location (up to 23 characters). b. Password: The currently
defined password is displayed next to the prompt. To re-define the password
(Default = [Enter]), key in the new password (up to 8 characters) and press [Enter]. The password can include blank spaces and higher order
ASCII characters. Note that the Backspace key will not function file:///C|/WEBPAGE/guides/rpbp/build/rpbpguid.htm (7 of 12) [3/9/2000
5:08:10 PM] _x000C_RPB+; Remote Power Boot Switch -- User's Guide during password definition. c. Default (Power-Up Default): Allows the
user to define default On/Off conditions for each switched plug as described in Section 4.1. Key in the desired Power-Up Defaults and press
[Enter]. d. Echo Mode: When Echo Mode is enabled, commands sent to the RPB+ will be echoed back to your PC or terminal, allowing
keyboard entries to be displayed by your communications program. To enable or disable the Echo Mode, type Y or N, press [Enter], then
continue with the parameter definition routine. When the "RPB+>" prompt returns, type /D [Enter]. q q Note: The Echo Mode will not be
enabled / disabled until the /D command is invoked. If the Default String includes invalid or missing characters, the /D command will not
function. e. Plug Labels: Allows the user to identify the device connected to each plug (e.g. "SERVER"). Key in the desired name (up to 16
characters) and press [Enter]. 4.1. The Power-Up Default String The Power-Up Default String allows the user to select default On/Off
conditions for each switched AC outlet. When the RPB+ is powered up, or when the /D command (Set Defaults) is invoked, each outlet will be
set according to the Default String. Note: q The Power-Up Default String includes five characters; each character determines the default
On/Off condition for the corresponding plug. The first character applies to Plug 1, the second character applies to Plug 2, and etc. q To set a
plug to default "ON" enter a one (1); to set a plug to default "OFF", enter a zero (0). q If the Default String includes invalid or missing
characters, plugs will be switched "Off" when the unit is powered up, regardless of the conditions shown by the Status Screen. In addition,
the /D command will not function. file:///C|/WEBPAGE/guides/rpbp/build/rpbpguid.htm (8 of 12) [3/9/2000 5:08:11 PM] _x000C_RPB+;
Remote Power Boot Switch -- User's Guide Example 1: To set default On/Off conditions as follows: ON: Plugs 1 and 5 OFF: Plugs 2, 3, and 4
The Power-Up Default String would be defined as "10001". Example 2: To set default plug conditions as follows: ON: Plugs 3, 4, and 5 OFF:
Plugs 1 and 2 The Power-Up Default String would be defined as "00111". 5. Operation The device connected to the Control Port must send
ASCII characters at the same data rate as the RPB+. The unit accepts 8 bits no parity, or 7 bits even or odd parity, but will always answer back
at 8 bits, no parity. Access the RPB+ Command Mode as described in Section 4, Step 1. When the "RPB+>" prompt appears, the user may
invoke the following commands. Note: q Commands are not case sensitive. q Wait for the "RPB+>" prompt to appear before entering
commands. The prompt will not re-appear until the previous command is complete. q If an invalid command or parameter is entered, the
RPB+ will respond with the "?" message. 1. Switch Plug(s) On: To power-on one or all of the five switched plugs, type /n ON [Enter]. Where
"n" is a plug number from 1 to 5 and an asterisk (*) indicates the command should be applied to all plugs. 2. Switch Plug(s) Off: To power-off
one or all of the five switched plugs, type /n OFF [Enter]. Where "n" is a plug number from 1 to 5 and an asterisk (*) indicates the command
should be applied to all plugs. Note that "OFF" can also be entered as "OF". 3. Boot Plug(s): To initiate a Boot cycle at one or all of the
switched plugs, type /n BOOT [Enter]. Where "n" is a plug number from 1 to 5 and an asterisk (*) indicates the command should be applied to
all plugs. Note that "BOOT" can also be entered as "B". The RPB+ will display a series of periods (dots) while the Boot cycle is in progress. 4.
Status: To display the Status Screen, type /S [Enter]. file:///C|/WEBPAGE/guides/rpbp/build/rpbpguid.htm (9 of 12) [3/9/2000 5:08:11 PM]
_x000C_RPB+; Remote Power Boot Switch -- User's Guide 5. Enter Parameters: To define parameters, such as the Location I.D., Power-Up
Default, and Plug Labels, type
/P [Enter] and refer to Section 4, Step 4. 6. Set Plugs to Default: To set all plugs to the Power-Up Defaults, type /D [Enter]. Note that if the
Default String includes missing or invalid characters, the /D command will not function. 7. Exit: To exit from command mode, type /X [Enter].
Note: When the /n ON/OFF/BOOT command is invoked, the port (n) must be specified by number. The Port Label cannot be used to specify
the desired port. ON / OFF / BOOT Examples: q To Switch Plug 3 ON, type /3 ON [Enter]. q To switch all plugs ON, type /* ON [Enter]. q To
switch plug 5 OFF, type /5 OFF [Enter]. q To switch all plugs OFF, type /* OFF [Enter]. q To initiate a boot cycle at Plug 2, type /2 BOOT
[Enter]. q To initiate a boot cycle at all plugs, type /* BOOT [Enter]. Appendix A. Specifications q Switched Power Plugs: 5 code-selectable AC
plugs rated 15 amps max. Each. Total switched power for all plugs not to exceed 15 amps. Unit initially powers up to ON condition. q RS232
Port: r DB9 Connector: A 9 Pin Male connector wired in a DTE configuration. Pin Signal I/O 1 DCD Carrier Detect
file:///C|/WEBPAGE/guides/rpbp/build/rpbpguid.htm (10 of 12) [3/9/2000 5:08:11 PM] _x000C_RPB+; Remote Power Boot Switch -- User's
Guide 2 3 4 5 6 7 8 9 r r RXD TXD DTR GND (NC) RTS (NC) (NC) Data Input Data Output Ready Output Signal Ground Not Connected RTS
Output Not Connected Not Connected Coding: Asynchronous. 7-8 bits, any parity Data Rate: 2400, 9600 bps (Switch Selectable) q LEDs:
Power ON, Control Input, Plug On (5) q Temperature: 0° C to 30° C (operating) q Power: r 115 VAC Model: Internal 115 VAC 60 Hz (15 Amps
Maximum Load). r 230 VAC Model: Internal 230 VAC 60 Hz (15 Amps Maximum Load). q Size: 1.75" x 17.00" x 6.5" (H x W x D). Requires one
rack space. q Mounting: 19" Rack Mount Bracket Included. 24" Rack Mount Bracket Optional. q Weight: 5 pounds shipping weight
Appendix B. Customer Service Customer Service hours are from 8:00 AM to 5:00 PM, PST, Monday through Friday. When calling, please be
prepared to give the name and make of the unit, its serial number and a description of its symptoms. If the unit should need to be returned
for factory repair it must be accompanied by a Return Authorization number from Customer Service. WTI Customer Service 5 Sterling
file:///C|/WEBPAGE/guides/rpbp/build/rpbpguid.htm (11 of 12) [3/9/2000 5:08:11 PM] _x000C_RPB+; Remote Power Boot Switch -- User's
Guide Irvine, California 92618 Toll Free (U.S. & Canada): 1-800-854-7226 Phone: 949-586-9950 Fax: 949-583-9514 EMail: service@wti.com FCC
Statement This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: 1. This device may not
cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired
operation. Trademark and Copyright Information WTI and Western Telematic are trademarks of Western Telematic Incorporated. All other
product names mentioned in this publication are trademarks of their respective companies. Information and descriptions contained herein
are the property of Western Telematic, Inc.. Such information and descriptions may not be copied, disseminated or distributed without the
express written consent of Western Telematic, Incorporated. © Copyright Western Telematic, Inc., 1998. All right reserved. Printed in the
United States of America. October 1998; March 2000 (HTML Version) WTI Part Number: 12651 Rev. B Western Telematic, Inc. 5 Sterling,
Irvine, California 92618-2517 USA U.S. & Canada: (800) 854-7226 Phone: (949) 586-9950 Fax: (949) 583-9515 www.wti.com
file:///C|/WEBPAGE/guides/rpbp/build/rpbpguid.htm (12 of 12) [3/9/2000 5:08:11 PM] _x000C_

More Related Content

PPTX
RNC Pilot PO Optimization
DOCX
Wcdma ps service_optimization_guide
PPTX
Huawei 3 g_capacity_optimization
PDF
Umts access kpi troubleshooting guide rrc
DOCX
2013 hspa optimization doc huawei
PDF
Zte hsdpa
PPTX
Alcatel-Lucent BNJ40B
PPTX
Evo bsc-8200
RNC Pilot PO Optimization
Wcdma ps service_optimization_guide
Huawei 3 g_capacity_optimization
Umts access kpi troubleshooting guide rrc
2013 hspa optimization doc huawei
Zte hsdpa
Alcatel-Lucent BNJ40B
Evo bsc-8200

What's hot (19)

PDF
Mohd_Noor_Azman_CV2015
PPTX
Adaptive configuration of traffic channel power offset for hsupa
PPTX
Multicarrier interworking strategy
PPTX
Feature adaptive configuration of traffic channel power offset for hsupa perf...
PDF
wcdma-paging-problem-analysis
PDF
Bsc parameter
PDF
Lte kpis
PPT
C C N A Day5
DOCX
How to resolve irat kpi issue in huawei
PPTX
150154357 umts-multi-carrier-strategy-training
PDF
Huawei wcdma traffic counter
PDF
Huawei - Access failures troubleshooting work shop
PDF
Chap 4. call processing and handover.eng
PPTX
DC-HSPA+ technology
PDF
Infoplc net s7_fc300
PDF
Hsdpa principles
PPT
Wcdma Radio Network Planning And Optimization
PPT
Halderman ch049 lecture
Mohd_Noor_Azman_CV2015
Adaptive configuration of traffic channel power offset for hsupa
Multicarrier interworking strategy
Feature adaptive configuration of traffic channel power offset for hsupa perf...
wcdma-paging-problem-analysis
Bsc parameter
Lte kpis
C C N A Day5
How to resolve irat kpi issue in huawei
150154357 umts-multi-carrier-strategy-training
Huawei wcdma traffic counter
Huawei - Access failures troubleshooting work shop
Chap 4. call processing and handover.eng
DC-HSPA+ technology
Infoplc net s7_fc300
Hsdpa principles
Wcdma Radio Network Planning And Optimization
Halderman ch049 lecture
Ad

Viewers also liked (18)

PPTX
Alcatel-Lucent 109761932
PPTX
Commscope-Andrew UNF-MF-4P-BK
PPTX
Carol FT-2-P-7K-123033
PPTX
Alcatel-Lucent 848379640
PPTX
Primus FLATWASH38SS
PPTX
Alcatel-Lucent J1C282AC-1, L1
PPTX
Commscope-Andrew LDF12-50
PPTX
Radwin RW-5520-0350
PPTX
Cisco WSC4003
PPTX
Trilogy GK-S12AC
PPTX
KMW 3M_RG-316_SMA
PPTX
Hubbell IB100
PPTX
Ericsson BMF904771
PPTX
Launch 3 L3-TAPE-2
PPTX
Southwire E5T583
PPTX
Alcatel-Lucent KLU1
PPTX
Motorola 01-W2845D03G
PPTX
Dialogic D/640SC
Alcatel-Lucent 109761932
Commscope-Andrew UNF-MF-4P-BK
Carol FT-2-P-7K-123033
Alcatel-Lucent 848379640
Primus FLATWASH38SS
Alcatel-Lucent J1C282AC-1, L1
Commscope-Andrew LDF12-50
Radwin RW-5520-0350
Cisco WSC4003
Trilogy GK-S12AC
KMW 3M_RG-316_SMA
Hubbell IB100
Ericsson BMF904771
Launch 3 L3-TAPE-2
Southwire E5T583
Alcatel-Lucent KLU1
Motorola 01-W2845D03G
Dialogic D/640SC
Ad

Similar to WTI RPB+ (20)

PPTX
WTI RPB-115
PPTX
RFS 815414-010P
PPTX
BTI BP1A56BA
PPTX
Ericsson RPM919664/1500
PPTX
Ericsson RPM 119 1693/70M
PPTX
ADC MPPGXGBA4
PPTX
Ericsson RPM777 01/01600
PPTX
Ericsson RPM5131821/02100
PPTX
Ericsson RPM 777 157/02000
PPTX
Ericsson RPM513705/00440
PPTX
Ericsson RPM513705/00440
PPTX
Ericsson RPM513183901600
PPTX
Ericsson RPM513178200410
PPTX
Ericsson RPM7770900600
PPTX
RFS DCB-20D
PPTX
Ericsson RPM77701/0100
PPTX
3Com RFF2SBTB
PPTX
Ericsson RPM5131668/01800
PPTX
RFS 15570570
PPTX
Ericsson RPM77709/01100
WTI RPB-115
RFS 815414-010P
BTI BP1A56BA
Ericsson RPM919664/1500
Ericsson RPM 119 1693/70M
ADC MPPGXGBA4
Ericsson RPM777 01/01600
Ericsson RPM5131821/02100
Ericsson RPM 777 157/02000
Ericsson RPM513705/00440
Ericsson RPM513705/00440
Ericsson RPM513183901600
Ericsson RPM513178200410
Ericsson RPM7770900600
RFS DCB-20D
Ericsson RPM77701/0100
3Com RFF2SBTB
Ericsson RPM5131668/01800
RFS 15570570
Ericsson RPM77709/01100

WTI RPB+

  • 2. WTI RPB+ Remote Power Switch _______________________________________ How to Buy Call: 1-877-878-9134 for this product Email: sales@launch3.net Click to send an RFQ: http://www.launch3telecom.com/wti/rpb.html
  • 3. Part number: RPB+ Datasheets: https://www.launch3telecom.com/shared_ media/datasheet/rpbpguid.pdf Manufacturer: WTI Weight: N/A Title: Remote Power Switch Category: N/A Description: Remote Power Switch Genre: N/A Heci: N/A Part Page URL:
  • 4. About Us Launch 3 Telecom is your one stop shop for all your Telecom and Data/Networking Hardware needs and genuine WTI replacement parts. We have loyally served our customers since 2003. Our product expertise, quality customer service, competitive pricing -on items like this WTI RPB+ -- are a few of the reasons why more telecom professionals buy from Launch 3 Telecom every day. _______________________________________ Payment and Processing We accept Visa, Mastercard, American Express and Paypal payments for this WTI RPB+. We can also accept Purchase Orders for Net Terms upon approval. Launch 3 Telecom does have a Government Cage Code so if this is for a Government purchase please tells us! You may also call us at 877-878-9134 or email us at sales@launch3.net for our credit card form. Please call us today to purchase this WTI RPB+ item while inventory and sale last.
  • 5. Same Day Shipping, Order Confirmation and Order Tracking Once your order is placed for the WTI RPB+, you may select from several shipping methods, including UPS, Federal Express, DHL, USPS, 3 day, 2 day, overnight and international methods. Orders received and approved before 3PM EST will generally ship the same business day. You will receive an order confirmation email for your WTI RPB+ along with the tracking number as soon as it is available. The tracking number will allow you to track your shipment in real time. We pack the WTI RPB+ in anti-static bubble wrap to ensure safe delivery. We will combine multiple items in one shipment whenever possible to save on shipping time and costs. Because we have several distribution points and vendor locations, sometimes orders will be divided into multiple shipments, but never at extra cost to you. _______________________________________ Warranty Every item you purchase from us includes a warranty and our hassle-free return policy. We stand by our product and your satisfaction is our goal. If you ever have questions or concerns about your WTI RPB+ order, simply contact our Customer Service Department at 877-878-9134, Monday - Friday, 9 AM - 5 PM EST. Friendly customer service reps are available to assist you with your order.
  • 6. Services from Launch 3 Telecom Launch 3 Telecom can also repair the WTI RPB+, provides maintenance contracts, De- installation, Telecom Consignment and Recycling. Please contact Launch 3 Telecom to learn more about these services! Launch 3 Telecom specializes in installation of all telecom related systems. Our team is equipped to handle all telecom equipment including cellular, Fixed Wireless, WiMAX, Central Office, and more. No project is too small or too big, and each is handled by a dedicated telecom professional. De-Installation - Our Network Installation Experts will properly de-install your equipment, package it, and ship it to our warehouse for storage. Testing - Our team of technicians will inspect each piece of equipment thoroughly. If a piece of equipment needs repair, we’ll provide the resources and technology to guarantee each piece is ready to be sold. Asset Recovery - We can store your equipment in one of our expansive warehouses located around the country until your equipment is sold so you can save on storage costs and avoid cluttering your equipment floor. Repair Services - Launch 3 Telecom is your one- stop solution to your entire Telecom Equipment & System repair. Our team of dedicated professionals will get your system back up and running quickly and efficiently. We repair cell sites, central office switching, combiners, data networking, transmission, power supplies, microwave, radios, IP Cameras, Sonet /SHD, power, power amps, CDMA, GSM, TDMA, and PBX Keyphone. Third Party Logistics - If you are currently operating a direct route or if you are interested in setting one up, Launch 3 Telecom would like to discuss the opportunity of sending you traffic. Contact us today to speak to a Call Termination Specialist for more details at voip@launch3telecom.com
  • 7. RPB+; Remote Power Boot Switch -- User's Guide WTI Part No.: 12651 Rev. B RPB+ Remote Power Boot Switch User's Guide 5 Sterling, Irvine, California 92618-2517 USA U.S. & Canada: (800) 854-7226 Phone: (949) 586-9950 Fax: (949) 583-9515 www.wti.com Table of Contents q 1. Introduction q 2. Unit Description r r q 2.1. Front Panel 2.2. Back Panel 3. Installation r 3.1. SetUp Switches r 3.2. Control Port Connection s r q 3.3. Power Connection 4. Start-Up / Configuration r q 3.2.1. Connecting to a Modem 4.1. The Power-Up Default String 5. Operation Appendices file:///C|/WEBPAGE/guides/rpbp/build/rpbpguid.htm (1 of 12) [3/9/2000 5:08:10 PM] _x000C_RPB+; Remote Power Boot Switch -- User's Guide q A. Specifications q B. Customer Service List of Figures q 1. Front Panel q 2. Back Panel q 3. RS-232 (Control Port) Interface Schematic q 4. RPB+ Cable Connections q 5. The Status Screen 1. Introduction Network equipment sometimes "locks-up", making it impossible to communicate. The RPB+ Remote Power Boot Switch can switch AC power on 5 individually controlled plugs, allowing attached equipment to reset (re-boot). ASCII commands are sent to the RS-232 Control Port to select plugs, and specify On, Off, or Boot operations. A convenient Status Screen shows On/Off conditions at each plug. RPB+ features include a security password, Location I.D. field, and plug labels to identify the device connected to each plug. Features: q Remotely Toggles AC Power to Five Separate Outlets. q Serial RS232 Control Port Interfaces Directly with a PC or External Modem, Allowing Local or Remote Control. q Status Display Shows Plug Labels and On/Off Conditions. q Simple ASCII Commands for On, Off, or Boot (Off/On). q User-Selectable Re-Boot Cycle Duration (Off Time). q User- Programmable Password Feature. q User-Programmable Location I.D. q User-Selectable Echo Mode. q User-Programmable Plug Labels. q User-Programmable Power-Up Defaults. q Requires Only One Rack Space. q Available in 115 VAC or 230 VAC Configurations Typographic Conventions file:///C|/WEBPAGE/guides/rpbp/build/rpbpguid.htm (2 of 12) [3/9/2000 5:08:10 PM] _x000C_RPB+; Remote Power Boot Switch -- User's Guide Throughout this manual, typefaces and characters have been used to denote the following: COURIER FONT Indicates characters typed on the keyboard. For example, /S or /3 ON. [Bold Font] Text set in bold face and enclosed in square brackets indicates a specific key. For example, [Enter] or [Esc]. 2. Unit Description 2.1. Front Panel Figure 1: Front Panel As shown in Figure 1, the RPB+ front panel includes a series of LED indicators which function as follows: 1. POWER ON: Lights when AC Power is applied to the RPB+. 2. DATA INPUT: Flashes when ASCII commands are received at the Control Port. 3. PLUG ON (Plugs 1 - 5): Lights when the corresponding plug is switched On. 2.2. Back Panel Figure 2: Back Panel As shown in Figure 2, the RPB+ back panel includes the following items: file:///C|/WEBPAGE/guides/rpbp/build/rpbpguid.htm (3 of 12) [3/9/2000 5:08:10 PM] _x000C_RPB+; Remote Power Boot Switch -- User's Guide 1. Switched AC Outlets (Plugs 1 - 5): For connection to up to five AC devices. Each outlet is capable of switching up to 15 Amps. The total for all five outlets must not exceed 15 Amps. 2. SetUp Switches (RATE): A bank of four DIP Switches which set the Control Port baud rate, select the Off Time duration, enable/disable the Password Option, and enable/disable the Read Only Mode. 3. RS232 (Control) Port: For connection to an external modem or local PC. The RPB+ accepts ASCII commands via the Control Port. 4. DEFAULT Button: Reads Rate Switch settings and sets parameters accordingly. This allows the user to change Rate Switch settings without re-booting the RPB+ and connected devices. The Default Button can also be used to bypass the Password Prompt. 5. Power Cable (115 VAC Units) Power Cable Receptacle (230 VAC Units) 6. Circuit Breaker: 15 Amps 7. Power Switch 3. Installation 3.1. SetUp Switches The SetUp Switches select the baud rate and Off Time, and enable/disable the Password feature and Read Only Mode. If switch settings are changed while the unit is powered On, press the Default Button to re-read switches. The Default Button allows the user to change switch settings while power is on, without re-booting the RPB+ and connected devices. Note: If Rate Switch
  • 8. settings are changed while the unit is powered on, new parameters will not take effect until the Default Button is pressed, or the RPB+ is powered Off and On. Off Time: When a boot cycle is initiated, the "Off Time" determines the length of time the device will remain off until power is restored. Password: When enabled, a password is required in order to access the RPB+ Command Mode (Default = [Enter]). To re- define the Password, refer to Section 4. Read Only Mode: When enabled, the /P command (Define Parameters) is suppressed. This file:///C|/WEBPAGE/guides/rpbp/build/rpbpguid.htm (4 of 12) [3/9/2000 5:08:10 PM] _x000C_RPB+; Remote Power Boot Switch -- User's Guide allows the user to invoke On/Off/Boot commands, but prevents redefinition of parameters such as the Password and Power-Up Default. Switch Function Up Down 1 Control Port Baud Rate 2 Off Time 10 sec. 5 sec.* 3 Password Function Disable Enable* 4 Read Only Mode Enable Disable* 2400 bps 9600 bps* * = Factory Setting 3.2. Control Port Connection The male, DB9 connector (labeled "RS232") is used for connection to an external modem or local PC. The RS232 Port uses a DTE configuration, similar to an AT computer. Figure 3 describes the Control Port interface. Figure 3: RS-232 (Control Port) Interface Schematic 3.2.1. Connecting to a Modem When connecting directly to an external modem, use a standard AT to Modem cable. Make certain the modem is initialized at the same baud rate as the RPB+ (SetUp Switch 1). The modem must be placed in Auto-Answer mode, and set to answer in one ring. Please refer to the user's guide for your external modem in order to determine the appropriate AT command file:///C|/WEBPAGE/guides/rpbp/build/rpbpguid.htm (5 of 12) [3/9/2000 5:08:10 PM] _x000C_RPB+; Remote Power Boot Switch -- User's Guide string. 3.3. Power Connection The Power Switch located on the back panel must be "On" in order for the RPB+ to operate. Each time the unit is powered On, the five AC outlets will be switched On or Off, as dictated by the Power-Up Default String (see Section 4.1). Each outlet is capable of switching up to 15 Amps of AC power. The total for all 5 outlets cannot exceed 15 Amps. Figure 4: RPB+ Cable Connections 4. Start-Up / Configuration 1. Access the RPB+ Command Mode: The RPB+ is transparent to parity and will accept 7 or 8 bit characters, but will always answer back at 8 bits, no parity. Make certain your communications program (e.g. ProComm) is set for the appropriate baud rate, bits, and parity. It is also recommended to set the communications program for TTY mode. . Via Modem: Start your communications program. Dial the external modem connected to the RPB+. Wait for the Connect message and proceed to Step 2. b. Via Local PC: Start your communications program. file:///C|/WEBPAGE/guides/rpbp/build/rpbpguid.htm (6 of 12) [3/9/2000 5:08:10 PM] _x000C_RPB+; Remote Power Boot Switch -- User's Guide 2. Password: If the Password function is enabled, the unit will display a prompt. Key in the Password and press [Enter]. If the password has not yet been defined, just press [Enter]. Note: q The Password feature is case sensitive. q If you forget your password, press the Default Button when the Password Prompt appears, then invoke the /P command to display the Password. 3. The RPB+ will display the Status Screen (Figure 5). Location: WESTERN TELEMATIC, INC. Default: 01110 Plug 1 2 3 4 5 Label PRINTER SERVER ONE SERVER TWO MODEM BANK FAX Condition OFF ON ON ON OFF Command Summary: /S Status /P Enter Parameters /D Set Plugs to Default /X Exit To Switch /n s Where n = Plug #, * = All, and s = ON/OFF/BOOT RPB+> Figure 5: The Status Screen 4. When the "RPB+>" prompt appears, type /P [Enter] to define system parameters. The unit will display a series of prompts. Note: q RPB+ commands are not case sensitive. q To skip a prompt without changing its current definition, press [Enter]. q To exit from the Define Parameters function, press [Esc] at any time. Parameters defined up to that point will be saved. . Location: Key in a text string that describes the RPB+ location (up to 23 characters). b. Password: The currently defined password is displayed next to the prompt. To re-define the password
  • 9. (Default = [Enter]), key in the new password (up to 8 characters) and press [Enter]. The password can include blank spaces and higher order ASCII characters. Note that the Backspace key will not function file:///C|/WEBPAGE/guides/rpbp/build/rpbpguid.htm (7 of 12) [3/9/2000 5:08:10 PM] _x000C_RPB+; Remote Power Boot Switch -- User's Guide during password definition. c. Default (Power-Up Default): Allows the user to define default On/Off conditions for each switched plug as described in Section 4.1. Key in the desired Power-Up Defaults and press [Enter]. d. Echo Mode: When Echo Mode is enabled, commands sent to the RPB+ will be echoed back to your PC or terminal, allowing keyboard entries to be displayed by your communications program. To enable or disable the Echo Mode, type Y or N, press [Enter], then continue with the parameter definition routine. When the "RPB+>" prompt returns, type /D [Enter]. q q Note: The Echo Mode will not be enabled / disabled until the /D command is invoked. If the Default String includes invalid or missing characters, the /D command will not function. e. Plug Labels: Allows the user to identify the device connected to each plug (e.g. "SERVER"). Key in the desired name (up to 16 characters) and press [Enter]. 4.1. The Power-Up Default String The Power-Up Default String allows the user to select default On/Off conditions for each switched AC outlet. When the RPB+ is powered up, or when the /D command (Set Defaults) is invoked, each outlet will be set according to the Default String. Note: q The Power-Up Default String includes five characters; each character determines the default On/Off condition for the corresponding plug. The first character applies to Plug 1, the second character applies to Plug 2, and etc. q To set a plug to default "ON" enter a one (1); to set a plug to default "OFF", enter a zero (0). q If the Default String includes invalid or missing characters, plugs will be switched "Off" when the unit is powered up, regardless of the conditions shown by the Status Screen. In addition, the /D command will not function. file:///C|/WEBPAGE/guides/rpbp/build/rpbpguid.htm (8 of 12) [3/9/2000 5:08:11 PM] _x000C_RPB+; Remote Power Boot Switch -- User's Guide Example 1: To set default On/Off conditions as follows: ON: Plugs 1 and 5 OFF: Plugs 2, 3, and 4 The Power-Up Default String would be defined as "10001". Example 2: To set default plug conditions as follows: ON: Plugs 3, 4, and 5 OFF: Plugs 1 and 2 The Power-Up Default String would be defined as "00111". 5. Operation The device connected to the Control Port must send ASCII characters at the same data rate as the RPB+. The unit accepts 8 bits no parity, or 7 bits even or odd parity, but will always answer back at 8 bits, no parity. Access the RPB+ Command Mode as described in Section 4, Step 1. When the "RPB+>" prompt appears, the user may invoke the following commands. Note: q Commands are not case sensitive. q Wait for the "RPB+>" prompt to appear before entering commands. The prompt will not re-appear until the previous command is complete. q If an invalid command or parameter is entered, the RPB+ will respond with the "?" message. 1. Switch Plug(s) On: To power-on one or all of the five switched plugs, type /n ON [Enter]. Where "n" is a plug number from 1 to 5 and an asterisk (*) indicates the command should be applied to all plugs. 2. Switch Plug(s) Off: To power-off one or all of the five switched plugs, type /n OFF [Enter]. Where "n" is a plug number from 1 to 5 and an asterisk (*) indicates the command should be applied to all plugs. Note that "OFF" can also be entered as "OF". 3. Boot Plug(s): To initiate a Boot cycle at one or all of the switched plugs, type /n BOOT [Enter]. Where "n" is a plug number from 1 to 5 and an asterisk (*) indicates the command should be applied to all plugs. Note that "BOOT" can also be entered as "B". The RPB+ will display a series of periods (dots) while the Boot cycle is in progress. 4. Status: To display the Status Screen, type /S [Enter]. file:///C|/WEBPAGE/guides/rpbp/build/rpbpguid.htm (9 of 12) [3/9/2000 5:08:11 PM] _x000C_RPB+; Remote Power Boot Switch -- User's Guide 5. Enter Parameters: To define parameters, such as the Location I.D., Power-Up Default, and Plug Labels, type
  • 10. /P [Enter] and refer to Section 4, Step 4. 6. Set Plugs to Default: To set all plugs to the Power-Up Defaults, type /D [Enter]. Note that if the Default String includes missing or invalid characters, the /D command will not function. 7. Exit: To exit from command mode, type /X [Enter]. Note: When the /n ON/OFF/BOOT command is invoked, the port (n) must be specified by number. The Port Label cannot be used to specify the desired port. ON / OFF / BOOT Examples: q To Switch Plug 3 ON, type /3 ON [Enter]. q To switch all plugs ON, type /* ON [Enter]. q To switch plug 5 OFF, type /5 OFF [Enter]. q To switch all plugs OFF, type /* OFF [Enter]. q To initiate a boot cycle at Plug 2, type /2 BOOT [Enter]. q To initiate a boot cycle at all plugs, type /* BOOT [Enter]. Appendix A. Specifications q Switched Power Plugs: 5 code-selectable AC plugs rated 15 amps max. Each. Total switched power for all plugs not to exceed 15 amps. Unit initially powers up to ON condition. q RS232 Port: r DB9 Connector: A 9 Pin Male connector wired in a DTE configuration. Pin Signal I/O 1 DCD Carrier Detect file:///C|/WEBPAGE/guides/rpbp/build/rpbpguid.htm (10 of 12) [3/9/2000 5:08:11 PM] _x000C_RPB+; Remote Power Boot Switch -- User's Guide 2 3 4 5 6 7 8 9 r r RXD TXD DTR GND (NC) RTS (NC) (NC) Data Input Data Output Ready Output Signal Ground Not Connected RTS Output Not Connected Not Connected Coding: Asynchronous. 7-8 bits, any parity Data Rate: 2400, 9600 bps (Switch Selectable) q LEDs: Power ON, Control Input, Plug On (5) q Temperature: 0° C to 30° C (operating) q Power: r 115 VAC Model: Internal 115 VAC 60 Hz (15 Amps Maximum Load). r 230 VAC Model: Internal 230 VAC 60 Hz (15 Amps Maximum Load). q Size: 1.75" x 17.00" x 6.5" (H x W x D). Requires one rack space. q Mounting: 19" Rack Mount Bracket Included. 24" Rack Mount Bracket Optional. q Weight: 5 pounds shipping weight Appendix B. Customer Service Customer Service hours are from 8:00 AM to 5:00 PM, PST, Monday through Friday. When calling, please be prepared to give the name and make of the unit, its serial number and a description of its symptoms. If the unit should need to be returned for factory repair it must be accompanied by a Return Authorization number from Customer Service. WTI Customer Service 5 Sterling file:///C|/WEBPAGE/guides/rpbp/build/rpbpguid.htm (11 of 12) [3/9/2000 5:08:11 PM] _x000C_RPB+; Remote Power Boot Switch -- User's Guide Irvine, California 92618 Toll Free (U.S. & Canada): 1-800-854-7226 Phone: 949-586-9950 Fax: 949-583-9514 EMail: service@wti.com FCC Statement This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. Trademark and Copyright Information WTI and Western Telematic are trademarks of Western Telematic Incorporated. All other product names mentioned in this publication are trademarks of their respective companies. Information and descriptions contained herein are the property of Western Telematic, Inc.. Such information and descriptions may not be copied, disseminated or distributed without the express written consent of Western Telematic, Incorporated. © Copyright Western Telematic, Inc., 1998. All right reserved. Printed in the United States of America. October 1998; March 2000 (HTML Version) WTI Part Number: 12651 Rev. B Western Telematic, Inc. 5 Sterling, Irvine, California 92618-2517 USA U.S. & Canada: (800) 854-7226 Phone: (949) 586-9950 Fax: (949) 583-9515 www.wti.com file:///C|/WEBPAGE/guides/rpbp/build/rpbpguid.htm (12 of 12) [3/9/2000 5:08:11 PM] _x000C_