Is a technique used to separate and identify
the components of a mixture.
Works by allowing the molecules present in
the mixture to distribute themselves
between a stationary and a mobile
medium.
Molecules that spend most of their time in
the mobile phase are carried along faster.
Chromatography
Invention of Chromatography
Mikhail Tswett
Russian Botanist
(1872-1919)
Mikhail Tswett invented
chromatography in 1901
during his research on
plant pigments.
He used the technique to
separate various plant
pigments such as
chlorophylls, xanthophylls
and carotenoids.
Chromatography: (Greek = chroma “color” and
graphein “writing” ) Tswett named this new technique
chromatography based on the fact that it separated the
components of a solution by color.
Common Types of Chromatography
Tswett’s technique is based on Liquid Chromatography.
There are now several common chromatographic
methods. These include:
Paper Chromatography
Thin Layer Chromatography (TLC)
Liquid Chromatography (LC)
High Pressure Liquid Chromatography (HPLC)
Ion Chromatography
Gas Chromatography (GC)
Thin Layer Chromatography
Here the mobile phase is a liquid
Flowing past a thin layer of powder on a solid support.
Substances that are less attracted to the solid or are more
soluble in the liquid move faster.
And so move further up the plate by the time that the
process has been stopped by taking the plate out of the
liqiud. - larger Rf
THIN LAYER CHROMATOGRAPHY
Stationary Phase ---------> Silica Gel
Mobile Phase -------------> Solvent
(developing)
SOLVENT
SPOT
DEVELOPING
CHAMBER
Origin
Solvent
Front
1.1 cm
5.5 cm
Rf =
Distance from starting origin to center of zone
Distance from starting origin to solvent front
=
5.5
11
= 0.5
THIN LAYER CHROMATOGRAPHY
Paper and Thin Layer Chromatography
Later
The solvent moves up paper by capillary action,
carrying mixture components at different rates.
solvent
solvent
front
Chromatography and its applications by Dr.A.DINESH KARTHIK
Rf = distance moved by substance
distance moved by solvent front
For substances that are very soluble in the liquid
Rf will be close to ....
For substances that are rather insoluble in the liquid
Rf will be close to ....
1
0
Comparing Chromatography to the
Flow of a River...
Base
Water flow
Light leaf
Heavy stone
How Does Chromatography Work?
In all chromatographic separations, the sample is transported
in a mobile phase. The mobile phase can be a gas, a liquid,
or a supercritical fluid.
The mobile phase is then forced through a stationary phase
held in a column or on a solid surface. The stationary phase
needs to be something that does not react with the mobile
phase or the sample.
The sample then has the opportunity to interact with the
stationary phase as it moves past it. Samples that interact
greatly, then appear to move more slowly. Samples that
interact weakly, then appear to move more quickly. Because
of this difference in rates, the samples can then be
separated into their components.
Mobile Phase / Stationary Phase
● A site in which a moving phase
(mobile phase) and a non-
moving phase (stationary
phase) make contact via an
interface that is set up.
● The affinity with the mobile
phase and stationary phase
varies with the solute. 
Separation occurs due to
differences in the speed of
motion.
Strong Weak
Mobile
phase
Stationary
phase
Gas Liquid Chromatography
Here the mobile phase is an unreactive gas ( eg
Nitrogen) flowing through a tube.
And the stationary phase is an involatile liquid
held on particles of a solid support.
Column Chromatography and Planar
Chromatography
Separation column
Packing material
Column Chromatography
Paper or a
substrate coated
with particles
Paper Chromatography
Thin Layer Chromatography (TLC)
Separation Process and Chromatogram for
Column Chromatography
Output
concentration
Time
Chromatogram
Chromatogram
tR
t0
Intensityofdetectorsignal
Time
Peak tR : Retention time
h
A
t0 : Non-retention time
A : Peak area
h : Peak height
Ion Exchange Chromatography
N+
R
R
R
SO3
-
+
+
+
++
++
+
+
+
Electrostatic interaction
(Coulomb force)
Anion exchange
Cation exchange
Stationary Phase Used in Ion
Exchange Mode
● Base Material
– Resin is often used.
– Silica gel is also used.
● Cation Exchange Column
– Strong cation exchange (SCX) -SO3
-
– Week cation exchange (WCX) -COO-
● Anion Exchange Column
– Strong anion exchange (SAX) -NR3
+
– Week anion exchange (WAX) -NHR2
+
Dependence of Exchange Capacity of Ion
Exchanger on pH of Eluent
Exchange
capacity
Exchange
capacity
pH
0 7 14
pH
0 7 14
Weakly acidic
cation
exchanger
Strongly acidic
cation
exchanger
Weakly basic
anion
exchanger
Strongly basic
anion
exchanger
Cation exchange mode Anion exchange mode
Ion Exclusion Chromatography
H+
H+
H+
Strong acid ions are repelled by
charge and cannot enter the
pore.
Depending on the level of
dissociation, some weak acid ions can
enter the pore.
Relationship between Retention Time and Salt
Concentration of Eluent in Ion Exchange Mode
Resin ResinResin
The exchange
groups are in
equilibrium with
anions in the eluent.
An eluent ion is
driven away
and a solute ion
is adsorbed.
The solute ion is
driven away by an
eluent ion and is
adsorbed by the next
exchange group.
If the salt concentration of the eluent increases, the solutes are eluted sooner.
Solute ions and eluent ions compete for ion exchange groups.
Gas Chromatography (GC)
*Gas chromatography is a chromatographic technique that
can be used to separate volatile organic compounds.
*It consists of
a flowing mobile phase
an injection port
a separation column (the stationary phase)
an oven
a detector.
In the animation below the red molecules are more soluble
in the liquid (or less volatile) than are the green molecules.
The organic compounds are separated due to
differences in their partitioning behavior between
the mobile gas phase and the stationary phase in
the column.
Principle
Mobile phases are generally inert gases such as
helium, argon, or nitrogen.
The injection port consists of a rubber septum
through which a syringe needle is inserted to inject
the sample.
The injection port is maintained at a higher
temperature than the boiling point of the least
volatile component in the sample mixture.
Since the partitioning behavior is dependent on
temperature, the separation column is usually
contained in a thermostat-controlled oven.
Separating components with a wide range of boiling
points is accomplished by starting at a low oven
temperature and increasing the temperature over time
to elute the high-boiling point components.
The more volatile (Low Boiling Point / Higher
Vapor Pressure) compounds arrive at the end of the
column first and pass into the detector
Components of a Gas Chromatograph
Gas Supply: (usually N2 or He)
Sample Injector: (syringe / septum)
Column: 1/8” or 1/4” x 6-50’ tubing packed with
small uniform size, inert support coated with
thin film of nonvolatile liquid
Detector: TC - thermal conductivity
FID - flame ionization detector
Chromatography and its applications by Dr.A.DINESH KARTHIK
Oven
Detector
Injection
port
Nitrogen
cylinder
Column
Recorder
Chromatography and its applications by Dr.A.DINESH KARTHIK
GC Theory
To
detector
Analyte
Column + packing
Time
Separations
To
detector
Time 1 Time 2 Time 3
Chromatography and its applications by Dr.A.DINESH KARTHIK
GC Columns
Capillary columnsPacked columns
•Typically a glass or stainless
steel coil.
•1-5 total length and 5 mm
inner diameter.
• Filled with the st. ph. or a
packing coated with the st.ph.
•Thin fused-silica.
•Typically 10-100 m in length
and 250 mm inner diameter.
•St. ph. coated on the inner
surface.
•Provide much higher
separation eff.
•But more easily overloaded
by too much sample.
1. Add about 1 tsp of dry/sifted Tide
to fill pipet within 1/4” of top
3. Use a plug of fiberfill
to hold Tide in place
(Tide has been sifted and dried,
so keep lid closed on container.)
2. Tap column with a pencil
to settle the powder.
Filling the Column
*Do not compact Tide into column.
**Do not leave any dead space at head of column.
A gas chromatography oven, open to
show a capillary column
GC Detectors
After the components of a mixture are separated using gas
chromatography, they must be detected as they exit the GC
column.
Thermal-conduc. (TCD) and flame ionization (FID) detectors
are the two most common detectors on commercial GCs.
The others are
1. Atomic-emmision detector (AED)
2. Chemiluminescence detector
3. Electron-capture detector (ECD)
4. Flame-photometric detector (FPD)
5. Mass spectrometer (MS)
6. Photoionization detector (PID)
GC Detectors Cont’d
The requirements of a GC detector depend on the separation
application.
E.g.
An analysis may require a detector selective for chlorine
containing molecules.
Another analysis might require a detector that is non-
destructive so that the analyte can be recovered for
further spectroscopic analysis. You can not use FID in
that case because it destroys the sample totally. TCD on the
other hand is non-destructive.
TCD Detector
A TCD detector consists of an electrically-heated wire.The
temperature of the sensing element depends on the thermal
conductivity of the gas flowing around it.
Changes in thermal conductivity, such as when organic
molecules displace some of the carrier gas, cause a
temperature rise in the element which is sensed as a change in
resistance.
The TCD is not as sensitive as other detectors but it is non-
specific and non-destructive.
ECD Detector
Uses a radiactive Beta emitter
(electrons) to ionize some of the
carrier gas and produces a current
between a biased pair of
electrodes.
When an org. mol. that contains
electornegative functional gr.,
such as halojens, phosphorous
and nitro groups, pass by the
detector, they capture some of the
electrons and reduce the current.
FID Detector
Consists of a hydrogen/air
flame and a collector plate.
The eff. from the GC
column passes through the
flame, shich breaks down org.
mol. and produces ions.
The ions are collected on a
biased electrode and produce
an elec. sig.
Extremely sensitive, large
dynamic range.
MS Detector
Uses the difference in mass-to-charge ratio (m/e) of ionized
atoms or molecules to separate them from each other.
Molecules have distinctive fragmentation patterns that provide
structural information to identify structural components.
The general operation of a mass spectrometer is:
1. create gas-phase ions
2. separate the ions in space or time based on their mass to
charge ratio
3. Measure the quantity of ions of each mass-to-charge ratio.
MS Detector Cont’d
The ion separation power of an MS is described by the
resolution:
R = m/Dm
Where m is the ion mass and Dm is the difference in mass
between two resolvable peaks in a mass spectrum.
E.g., an MS with a resolution of 1000 can resolve an ion with
a m/e of 100.0 from an ion with an m/e of 100.1.
GAS LIQUID CHROMATOGRAPHY
Principles
Partition of molecules between gas (mobile
phase) and liquid (stationary phase).
Gas-liquid chromatography (GLC)
Packed columns are fabricated from glass,
metal, or Teflon with 1 to 3 m length and 2 to
4 mm in internal diameter. The column is
packed with a solid support (100-400 mm
particle diameter made from diatomaceous
earth) that has been coated with a thin layer
(0.1-5 mm) of the stationary liquid phase.
Efficiency increases with decreasing particle
size as predicted from van Deemter equation.
The retention is based on absorption of
analyte (partition into the liquid stationary
phase) where solutes must have differential
solubility in the stationary phase
Open tubular capillary columns, either
WCOT, SCOT are routinely used. In WCOT
the capillary is coated with a thin film (0.1-
0.25 mm) of the liquid stationary phase while
in SCOT a thin film of solid support material
is first affixed to the inner surface of the
column then the support is coated with the
stationary phase. WCOT columns are most
widely used. Capillary columns are typically
made from fused silica (FSOT) and are 15 to
100 m long with 0.10 to 0.5 mm i.d.
The thickness of the stationary phase affects the
performance of the column as follows:
1. Increasing thickness of stationary phase allows the
separation of larger sample sizes.
2. Increasing thickness of stationary phase reduces
efficiency since HS increases.
3. Increasing thickness of stationary phase is better for
separation of highly volatile compounds due to
increased retention.
49
Much more efficient separations can be achieved
with capillary columns, as compared to packed
columns, due to the following reasons:
1. Very long capillary columns can be used which
increases efficiency
2. Thinner stationary phase films can be used with
capillary columns
3. No eddy diffusion term (multiple paths effect) is
observed in capillary columns
Gas-solid chromatography (GSC)
Gas-solid chromatography is based upon adsorption
of gaseous substances on solid surfaces.
Distribution coefficients are generally much larger
than those for gas-liquid chromatography.
Consequently, gas-solid chromatography is useful
for the separation of species that are not retained
by gas-liquid columns, such as the components of
air, hydrogen sulfide, carbon disulfide, nitrogen
oxides, and rare gases.
Gas-solid chromatography is performed with both
packed and open tubular columns.
 Separation and analysis of organic compounds
 Testing purity of compounds
 Determine relative amounts of components in mixture
 Compound identification
 Isolation of pure compounds (microscale work)
 Similar to column chromatography, but differs in 3 ways:
 Partitioning process carried out between Moving Gas Phase and
Stationary Liquid Phase
 Temperature of gas can be controlled
 Concentration of compound in gas phase is a function of the vapor
pressure only.
 GC also known as Vapor-Phase Chromatography (VPC) and Gas-
Liquid Partition Chromatography (GLPC)
Gas Chromatography Application
SEMI- QUANTITATIVE ANALYSIS OF FATTY ACIDS
C
C
C
Detector Response
Retention Time
14
16
18 Peak Area (cm )
Sample Concentration (mg/ml)
2
4
6
8
10
0.5 1.0 1.5 2.0 2.5 3.0
2
The content % of C fatty acids =
C
C + C + C



= the content % of C fatty acids14
14
TENTATIVE IDENTIFICATION OF UNKNOWN COMPOUNDS
Response
GC Retention Time on Carbowax-20 (min)
Mixture of known compounds
Hexane
Octane
Decane
1.6 min = RT
Response
Unknown compound may be Hexane
1.6 min = RT
Retention Time on Carbowax-20 (min)
GLC ADVANTAGES
1. Very good separation
2. Time (analysis is short)
3. Small sample is needed - ml
4. Good detection system
5. Quantitatively analyzed
Food and Cancer
● Chemicals that can cause cancer have a wide
variety of molecular structures and include
hydrocarbons, amines, certain drugs, some metals
and even some substances occurring naturally in
plants and molds.
● In this way, many nitrosamines have carcinogenic
properties and these are produced in a number of
ways such as cigarette smoke.
● GC can be used to identify these nitro-compounds
in trace quantities.
Drugs
● There are still numerous GC applications involving both
quantitative and qualitative identification of the active
components and possible contaminants, adulterants or
characteristic features which may indicate the source of
the particular sample.
● Forensic analysis frequently users GC to characterize
drugs of abuse, in some cases the characteristic
chromatographic fingerprint gives an indication of the
source of manufacture of the sample or worldwide
source of a vegetable material such as cannabis.
● Analytical procedures, chromatographic methods and
retention data are published for over 600 drugs, poisons
and metabolites. These data are extremely useful for
forensic work and in hospital pathology laboratories to
assist the identification of drugs.
DISADVANTAGES OF GAS CHROMATOGRAPHY
Material has to be volatilized at 250C without decomposition.
R C OH CH3OH H2SO4
O
R C O CH3
O
CH2 O C R
CH O C R
CH2 O C R
O
O
O
CH3OH
O
R C O CH3
CH3ONa
Fatty Acids Methylester
Reflux
+ 3
Volatile in Gas
Chromatography
Volatile in Gas
Chromatography
+ +
Dr.A.DINESH KARTHIK
dineshkarthik2008@gmail.com
Chromatography and its applications by Dr.A.DINESH KARTHIK

More Related Content

DOCX
Introduction to chromatography
PPTX
Column chromatography
PPT
Column chromatography
PPT
Chromatography
PDF
Introduction of chromatography
PPT
Chromatography
PPTX
Chromatography techniques
PPT
Partab chromatography ppt
Introduction to chromatography
Column chromatography
Column chromatography
Chromatography
Introduction of chromatography
Chromatography
Chromatography techniques
Partab chromatography ppt

What's hot (20)

PPTX
Column chromatography
PDF
Column Chromatography
PPT
Lecture of chromatography
PPTX
Colum chromatography
PPTX
Thin layer chromatography
PPTX
instrumentation of HPLC
PPTX
Basic concept of chromatography
PPTX
Reverse phase chromatography
PPT
Chromatography, types by different approaches, HPLC
PDF
PDF
Chromatography
PPTX
chromatographic techniques
PPTX
Column chromatography mahendra
PPTX
Types of chromatography
PPTX
Chromatography presentation
PPT
Chromatography introduction ppt by Akshay patel
PPTX
Hplc by Bachaspati jana
PPTX
Chromatography
DOCX
CHROMATOGRAPHY-PRINCIPLE, TYPES
PPTX
Columnchromatography
Column chromatography
Column Chromatography
Lecture of chromatography
Colum chromatography
Thin layer chromatography
instrumentation of HPLC
Basic concept of chromatography
Reverse phase chromatography
Chromatography, types by different approaches, HPLC
Chromatography
chromatographic techniques
Column chromatography mahendra
Types of chromatography
Chromatography presentation
Chromatography introduction ppt by Akshay patel
Hplc by Bachaspati jana
Chromatography
CHROMATOGRAPHY-PRINCIPLE, TYPES
Columnchromatography
Ad

Similar to Chromatography and its applications by Dr.A.DINESH KARTHIK (20)

PPT
Chromatography
PPTX
Gas chromatography-GC
PPTX
GC Power Point.pptx
DOCX
Chromatography
PPTX
Gas chromatography
PPT
Gas chromatography
PPT
Chromatography lc ms
PPTX
Modern chromatographic technique.pptx
DOCX
Chromatography 120726045329-phpapp02
PPTX
Gas Chromatography
DOCX
Gas chromatography
PPTX
Gas chromatography
PPTX
GAS CHROMATOGRAPHY/ SAGAR SHARMA/DEPARTMENT OF PHARMACEUTICAL SCIENCES KUK
PPTX
chromatography principle and procedure^^.pptx
PDF
AMI Unit 4 Notes.pdf
PPTX
Gas Chromatography.pptx
PDF
Unit 2 BAT Chromatography.pdf
PPTX
HPTLC and GC chromatography Assignment.pptx
PDF
Gas chromatography (1)
Chromatography
Gas chromatography-GC
GC Power Point.pptx
Chromatography
Gas chromatography
Gas chromatography
Chromatography lc ms
Modern chromatographic technique.pptx
Chromatography 120726045329-phpapp02
Gas Chromatography
Gas chromatography
Gas chromatography
GAS CHROMATOGRAPHY/ SAGAR SHARMA/DEPARTMENT OF PHARMACEUTICAL SCIENCES KUK
chromatography principle and procedure^^.pptx
AMI Unit 4 Notes.pdf
Gas Chromatography.pptx
Unit 2 BAT Chromatography.pdf
HPTLC and GC chromatography Assignment.pptx
Gas chromatography (1)
Ad

More from Dr.A.DINESH KARTHIK (11)

PDF
Environmental Studies Dr.A.D.K 2Y III-Sem
PPTX
Dr ADK MSc Electrochemistry Elective Unit II B.pptx
PPTX
Dr ADK MSc Electrochemistry Elective Unit II A .pptx
PPTX
A Career in Chemistry 19.07.2023
PPTX
BSc V SEM B Electrochemistry 1.pptx
PPTX
BSc Electrochemistry.pptx
PPTX
UNIT II B Conduct of Research Work .pptx
PPTX
UNIT II A Conduct of Research Work.pptx
PPT
High Performance Liquid Chromatography Dr.A.DINESH KARTHIK.ppt
PDF
Unit I B Research Methodolgy II MSc
PDF
Unit I A Research Methodolgy II MSc
Environmental Studies Dr.A.D.K 2Y III-Sem
Dr ADK MSc Electrochemistry Elective Unit II B.pptx
Dr ADK MSc Electrochemistry Elective Unit II A .pptx
A Career in Chemistry 19.07.2023
BSc V SEM B Electrochemistry 1.pptx
BSc Electrochemistry.pptx
UNIT II B Conduct of Research Work .pptx
UNIT II A Conduct of Research Work.pptx
High Performance Liquid Chromatography Dr.A.DINESH KARTHIK.ppt
Unit I B Research Methodolgy II MSc
Unit I A Research Methodolgy II MSc

Recently uploaded (20)

PPTX
famous lake in india and its disturibution and importance
PPTX
Comparative Structure of Integument in Vertebrates.pptx
PPTX
7. General Toxicologyfor clinical phrmacy.pptx
PDF
The scientific heritage No 166 (166) (2025)
PDF
bbec55_b34400a7914c42429908233dbd381773.pdf
PPTX
2. Earth - The Living Planet Module 2ELS
PPTX
ECG_Course_Presentation د.محمد صقران ppt
PPTX
Protein & Amino Acid Structures Levels of protein structure (primary, seconda...
PDF
MIRIDeepImagingSurvey(MIDIS)oftheHubbleUltraDeepField
PPTX
The KM-GBF monitoring framework – status & key messages.pptx
PPTX
GEN. BIO 1 - CELL TYPES & CELL MODIFICATIONS
PPTX
INTRODUCTION TO EVS | Concept of sustainability
PPT
Chemical bonding and molecular structure
PPTX
ANEMIA WITH LEUKOPENIA MDS 07_25.pptx htggtftgt fredrctvg
PPTX
Classification Systems_TAXONOMY_SCIENCE8.pptx
PPTX
TOTAL hIP ARTHROPLASTY Presentation.pptx
PDF
diccionario toefl examen de ingles para principiante
PPT
protein biochemistry.ppt for university classes
PPTX
DRUG THERAPY FOR SHOCK gjjjgfhhhhh.pptx.
PPTX
microscope-Lecturecjchchchchcuvuvhc.pptx
famous lake in india and its disturibution and importance
Comparative Structure of Integument in Vertebrates.pptx
7. General Toxicologyfor clinical phrmacy.pptx
The scientific heritage No 166 (166) (2025)
bbec55_b34400a7914c42429908233dbd381773.pdf
2. Earth - The Living Planet Module 2ELS
ECG_Course_Presentation د.محمد صقران ppt
Protein & Amino Acid Structures Levels of protein structure (primary, seconda...
MIRIDeepImagingSurvey(MIDIS)oftheHubbleUltraDeepField
The KM-GBF monitoring framework – status & key messages.pptx
GEN. BIO 1 - CELL TYPES & CELL MODIFICATIONS
INTRODUCTION TO EVS | Concept of sustainability
Chemical bonding and molecular structure
ANEMIA WITH LEUKOPENIA MDS 07_25.pptx htggtftgt fredrctvg
Classification Systems_TAXONOMY_SCIENCE8.pptx
TOTAL hIP ARTHROPLASTY Presentation.pptx
diccionario toefl examen de ingles para principiante
protein biochemistry.ppt for university classes
DRUG THERAPY FOR SHOCK gjjjgfhhhhh.pptx.
microscope-Lecturecjchchchchcuvuvhc.pptx

Chromatography and its applications by Dr.A.DINESH KARTHIK

  • 1. Dr.A.DINESH KARTHIK HEAD, P G & RESEARCH DEPT. OF CHEMISTRY SHANMUGA INDUSTRIES ARTS & SCIENCE COLLEGE, TIRUVANNAMALAI-606603.
  • 2. Is a technique used to separate and identify the components of a mixture. Works by allowing the molecules present in the mixture to distribute themselves between a stationary and a mobile medium. Molecules that spend most of their time in the mobile phase are carried along faster. Chromatography
  • 3. Invention of Chromatography Mikhail Tswett Russian Botanist (1872-1919) Mikhail Tswett invented chromatography in 1901 during his research on plant pigments. He used the technique to separate various plant pigments such as chlorophylls, xanthophylls and carotenoids.
  • 4. Chromatography: (Greek = chroma “color” and graphein “writing” ) Tswett named this new technique chromatography based on the fact that it separated the components of a solution by color. Common Types of Chromatography Tswett’s technique is based on Liquid Chromatography. There are now several common chromatographic methods. These include: Paper Chromatography Thin Layer Chromatography (TLC) Liquid Chromatography (LC) High Pressure Liquid Chromatography (HPLC) Ion Chromatography Gas Chromatography (GC)
  • 5. Thin Layer Chromatography Here the mobile phase is a liquid Flowing past a thin layer of powder on a solid support. Substances that are less attracted to the solid or are more soluble in the liquid move faster. And so move further up the plate by the time that the process has been stopped by taking the plate out of the liqiud. - larger Rf
  • 6. THIN LAYER CHROMATOGRAPHY Stationary Phase ---------> Silica Gel Mobile Phase -------------> Solvent (developing)
  • 7. SOLVENT SPOT DEVELOPING CHAMBER Origin Solvent Front 1.1 cm 5.5 cm Rf = Distance from starting origin to center of zone Distance from starting origin to solvent front = 5.5 11 = 0.5 THIN LAYER CHROMATOGRAPHY
  • 8. Paper and Thin Layer Chromatography Later The solvent moves up paper by capillary action, carrying mixture components at different rates. solvent solvent front
  • 10. Rf = distance moved by substance distance moved by solvent front For substances that are very soluble in the liquid Rf will be close to .... For substances that are rather insoluble in the liquid Rf will be close to .... 1 0
  • 11. Comparing Chromatography to the Flow of a River... Base Water flow Light leaf Heavy stone
  • 12. How Does Chromatography Work? In all chromatographic separations, the sample is transported in a mobile phase. The mobile phase can be a gas, a liquid, or a supercritical fluid. The mobile phase is then forced through a stationary phase held in a column or on a solid surface. The stationary phase needs to be something that does not react with the mobile phase or the sample. The sample then has the opportunity to interact with the stationary phase as it moves past it. Samples that interact greatly, then appear to move more slowly. Samples that interact weakly, then appear to move more quickly. Because of this difference in rates, the samples can then be separated into their components.
  • 13. Mobile Phase / Stationary Phase ● A site in which a moving phase (mobile phase) and a non- moving phase (stationary phase) make contact via an interface that is set up. ● The affinity with the mobile phase and stationary phase varies with the solute.  Separation occurs due to differences in the speed of motion. Strong Weak Mobile phase Stationary phase
  • 14. Gas Liquid Chromatography Here the mobile phase is an unreactive gas ( eg Nitrogen) flowing through a tube. And the stationary phase is an involatile liquid held on particles of a solid support.
  • 15. Column Chromatography and Planar Chromatography Separation column Packing material Column Chromatography Paper or a substrate coated with particles Paper Chromatography Thin Layer Chromatography (TLC)
  • 16. Separation Process and Chromatogram for Column Chromatography Output concentration Time Chromatogram
  • 17. Chromatogram tR t0 Intensityofdetectorsignal Time Peak tR : Retention time h A t0 : Non-retention time A : Peak area h : Peak height
  • 18. Ion Exchange Chromatography N+ R R R SO3 - + + + ++ ++ + + + Electrostatic interaction (Coulomb force) Anion exchange Cation exchange
  • 19. Stationary Phase Used in Ion Exchange Mode ● Base Material – Resin is often used. – Silica gel is also used. ● Cation Exchange Column – Strong cation exchange (SCX) -SO3 - – Week cation exchange (WCX) -COO- ● Anion Exchange Column – Strong anion exchange (SAX) -NR3 + – Week anion exchange (WAX) -NHR2 +
  • 20. Dependence of Exchange Capacity of Ion Exchanger on pH of Eluent Exchange capacity Exchange capacity pH 0 7 14 pH 0 7 14 Weakly acidic cation exchanger Strongly acidic cation exchanger Weakly basic anion exchanger Strongly basic anion exchanger Cation exchange mode Anion exchange mode
  • 21. Ion Exclusion Chromatography H+ H+ H+ Strong acid ions are repelled by charge and cannot enter the pore. Depending on the level of dissociation, some weak acid ions can enter the pore.
  • 22. Relationship between Retention Time and Salt Concentration of Eluent in Ion Exchange Mode Resin ResinResin The exchange groups are in equilibrium with anions in the eluent. An eluent ion is driven away and a solute ion is adsorbed. The solute ion is driven away by an eluent ion and is adsorbed by the next exchange group. If the salt concentration of the eluent increases, the solutes are eluted sooner. Solute ions and eluent ions compete for ion exchange groups.
  • 23. Gas Chromatography (GC) *Gas chromatography is a chromatographic technique that can be used to separate volatile organic compounds. *It consists of a flowing mobile phase an injection port a separation column (the stationary phase) an oven a detector.
  • 24. In the animation below the red molecules are more soluble in the liquid (or less volatile) than are the green molecules.
  • 25. The organic compounds are separated due to differences in their partitioning behavior between the mobile gas phase and the stationary phase in the column. Principle
  • 26. Mobile phases are generally inert gases such as helium, argon, or nitrogen. The injection port consists of a rubber septum through which a syringe needle is inserted to inject the sample. The injection port is maintained at a higher temperature than the boiling point of the least volatile component in the sample mixture.
  • 27. Since the partitioning behavior is dependent on temperature, the separation column is usually contained in a thermostat-controlled oven. Separating components with a wide range of boiling points is accomplished by starting at a low oven temperature and increasing the temperature over time to elute the high-boiling point components. The more volatile (Low Boiling Point / Higher Vapor Pressure) compounds arrive at the end of the column first and pass into the detector
  • 28. Components of a Gas Chromatograph Gas Supply: (usually N2 or He) Sample Injector: (syringe / septum) Column: 1/8” or 1/4” x 6-50’ tubing packed with small uniform size, inert support coated with thin film of nonvolatile liquid Detector: TC - thermal conductivity FID - flame ionization detector
  • 35. GC Columns Capillary columnsPacked columns •Typically a glass or stainless steel coil. •1-5 total length and 5 mm inner diameter. • Filled with the st. ph. or a packing coated with the st.ph. •Thin fused-silica. •Typically 10-100 m in length and 250 mm inner diameter. •St. ph. coated on the inner surface. •Provide much higher separation eff. •But more easily overloaded by too much sample.
  • 36. 1. Add about 1 tsp of dry/sifted Tide to fill pipet within 1/4” of top 3. Use a plug of fiberfill to hold Tide in place (Tide has been sifted and dried, so keep lid closed on container.) 2. Tap column with a pencil to settle the powder. Filling the Column *Do not compact Tide into column. **Do not leave any dead space at head of column.
  • 37. A gas chromatography oven, open to show a capillary column
  • 38. GC Detectors After the components of a mixture are separated using gas chromatography, they must be detected as they exit the GC column. Thermal-conduc. (TCD) and flame ionization (FID) detectors are the two most common detectors on commercial GCs. The others are 1. Atomic-emmision detector (AED) 2. Chemiluminescence detector 3. Electron-capture detector (ECD) 4. Flame-photometric detector (FPD) 5. Mass spectrometer (MS) 6. Photoionization detector (PID)
  • 39. GC Detectors Cont’d The requirements of a GC detector depend on the separation application. E.g. An analysis may require a detector selective for chlorine containing molecules. Another analysis might require a detector that is non- destructive so that the analyte can be recovered for further spectroscopic analysis. You can not use FID in that case because it destroys the sample totally. TCD on the other hand is non-destructive.
  • 40. TCD Detector A TCD detector consists of an electrically-heated wire.The temperature of the sensing element depends on the thermal conductivity of the gas flowing around it. Changes in thermal conductivity, such as when organic molecules displace some of the carrier gas, cause a temperature rise in the element which is sensed as a change in resistance. The TCD is not as sensitive as other detectors but it is non- specific and non-destructive.
  • 41. ECD Detector Uses a radiactive Beta emitter (electrons) to ionize some of the carrier gas and produces a current between a biased pair of electrodes. When an org. mol. that contains electornegative functional gr., such as halojens, phosphorous and nitro groups, pass by the detector, they capture some of the electrons and reduce the current.
  • 42. FID Detector Consists of a hydrogen/air flame and a collector plate. The eff. from the GC column passes through the flame, shich breaks down org. mol. and produces ions. The ions are collected on a biased electrode and produce an elec. sig. Extremely sensitive, large dynamic range.
  • 43. MS Detector Uses the difference in mass-to-charge ratio (m/e) of ionized atoms or molecules to separate them from each other. Molecules have distinctive fragmentation patterns that provide structural information to identify structural components. The general operation of a mass spectrometer is: 1. create gas-phase ions 2. separate the ions in space or time based on their mass to charge ratio 3. Measure the quantity of ions of each mass-to-charge ratio.
  • 44. MS Detector Cont’d The ion separation power of an MS is described by the resolution: R = m/Dm Where m is the ion mass and Dm is the difference in mass between two resolvable peaks in a mass spectrum. E.g., an MS with a resolution of 1000 can resolve an ion with a m/e of 100.0 from an ion with an m/e of 100.1.
  • 45. GAS LIQUID CHROMATOGRAPHY Principles Partition of molecules between gas (mobile phase) and liquid (stationary phase).
  • 46. Gas-liquid chromatography (GLC) Packed columns are fabricated from glass, metal, or Teflon with 1 to 3 m length and 2 to 4 mm in internal diameter. The column is packed with a solid support (100-400 mm particle diameter made from diatomaceous earth) that has been coated with a thin layer (0.1-5 mm) of the stationary liquid phase. Efficiency increases with decreasing particle size as predicted from van Deemter equation. The retention is based on absorption of analyte (partition into the liquid stationary phase) where solutes must have differential solubility in the stationary phase
  • 47. Open tubular capillary columns, either WCOT, SCOT are routinely used. In WCOT the capillary is coated with a thin film (0.1- 0.25 mm) of the liquid stationary phase while in SCOT a thin film of solid support material is first affixed to the inner surface of the column then the support is coated with the stationary phase. WCOT columns are most widely used. Capillary columns are typically made from fused silica (FSOT) and are 15 to 100 m long with 0.10 to 0.5 mm i.d.
  • 48. The thickness of the stationary phase affects the performance of the column as follows: 1. Increasing thickness of stationary phase allows the separation of larger sample sizes. 2. Increasing thickness of stationary phase reduces efficiency since HS increases. 3. Increasing thickness of stationary phase is better for separation of highly volatile compounds due to increased retention.
  • 49. 49 Much more efficient separations can be achieved with capillary columns, as compared to packed columns, due to the following reasons: 1. Very long capillary columns can be used which increases efficiency 2. Thinner stationary phase films can be used with capillary columns 3. No eddy diffusion term (multiple paths effect) is observed in capillary columns
  • 50. Gas-solid chromatography (GSC) Gas-solid chromatography is based upon adsorption of gaseous substances on solid surfaces. Distribution coefficients are generally much larger than those for gas-liquid chromatography. Consequently, gas-solid chromatography is useful for the separation of species that are not retained by gas-liquid columns, such as the components of air, hydrogen sulfide, carbon disulfide, nitrogen oxides, and rare gases. Gas-solid chromatography is performed with both packed and open tubular columns.
  • 51.  Separation and analysis of organic compounds  Testing purity of compounds  Determine relative amounts of components in mixture  Compound identification  Isolation of pure compounds (microscale work)  Similar to column chromatography, but differs in 3 ways:  Partitioning process carried out between Moving Gas Phase and Stationary Liquid Phase  Temperature of gas can be controlled  Concentration of compound in gas phase is a function of the vapor pressure only.  GC also known as Vapor-Phase Chromatography (VPC) and Gas- Liquid Partition Chromatography (GLPC) Gas Chromatography Application
  • 52. SEMI- QUANTITATIVE ANALYSIS OF FATTY ACIDS C C C Detector Response Retention Time 14 16 18 Peak Area (cm ) Sample Concentration (mg/ml) 2 4 6 8 10 0.5 1.0 1.5 2.0 2.5 3.0 2 The content % of C fatty acids = C C + C + C    = the content % of C fatty acids14 14
  • 53. TENTATIVE IDENTIFICATION OF UNKNOWN COMPOUNDS Response GC Retention Time on Carbowax-20 (min) Mixture of known compounds Hexane Octane Decane 1.6 min = RT Response Unknown compound may be Hexane 1.6 min = RT Retention Time on Carbowax-20 (min)
  • 54. GLC ADVANTAGES 1. Very good separation 2. Time (analysis is short) 3. Small sample is needed - ml 4. Good detection system 5. Quantitatively analyzed
  • 55. Food and Cancer ● Chemicals that can cause cancer have a wide variety of molecular structures and include hydrocarbons, amines, certain drugs, some metals and even some substances occurring naturally in plants and molds. ● In this way, many nitrosamines have carcinogenic properties and these are produced in a number of ways such as cigarette smoke. ● GC can be used to identify these nitro-compounds in trace quantities.
  • 56. Drugs ● There are still numerous GC applications involving both quantitative and qualitative identification of the active components and possible contaminants, adulterants or characteristic features which may indicate the source of the particular sample. ● Forensic analysis frequently users GC to characterize drugs of abuse, in some cases the characteristic chromatographic fingerprint gives an indication of the source of manufacture of the sample or worldwide source of a vegetable material such as cannabis. ● Analytical procedures, chromatographic methods and retention data are published for over 600 drugs, poisons and metabolites. These data are extremely useful for forensic work and in hospital pathology laboratories to assist the identification of drugs.
  • 57. DISADVANTAGES OF GAS CHROMATOGRAPHY Material has to be volatilized at 250C without decomposition. R C OH CH3OH H2SO4 O R C O CH3 O CH2 O C R CH O C R CH2 O C R O O O CH3OH O R C O CH3 CH3ONa Fatty Acids Methylester Reflux + 3 Volatile in Gas Chromatography Volatile in Gas Chromatography + +