SlideShare a Scribd company logo
2
Most read
4
Most read
6
Most read
Rev.1 07/2015-E
Neo SinusAll Kit
User Guide
Rev.1 07/2015
NB-SAK-IFU-001
Sinus Elevator
SCA
Kit
SLA
Kit
+ +
Surgical
Kit
Neo SinusAll Kit
This product is a SinusAll Kit, consisting of dental implant surgical tools (drills, surgical tools,
and drivers) made out of medical grade materials, including stainless steel.
Product description
The SinusAll Kit combines NeoBiotech’s SCA (Sinus Crestal Approach) Kit, SLA (Sinus
Lateral Approach) Kit, and the Surgical Kit into a single kit. The product allows maxillary sinus
implant procedures to take place using a single kit, rather than having to prepare a sinus kit
and a surgical kit separately.
Intended use
Rev.1 07/2015
NB-SAK-IFU-001
Ø2.0 Ø4.0Ø3.7Ø3.2Ø2.8
12.0
11.0
10.0
9.0
8.0
7.0
6.0
5.0
4.0
3.0
2.0
1.0
0.0
0.2
Ø2.8 Ø3.9Ø3.6Ø3.2
Store at room temperature in a dry location away from direct light.
Preservation
1
2
3
4
Prior to using this product, the clinician must completely understand the condition, perfor-
mance, and function of the product.
Use only after raising any doubts and verifying any issues with the manufacturer.
For the procedure, a plan must be first established, based on checking the patient’s oral
condition and accurate judgments.
After taking into consideration the condition of the patient, tools appropriate for the proce-
dure must be prepared.
How to Prepare Before Use
<Crestal Approach Tool Components>
Components
Surgical Drill1
Consist of a total of five types :
Ø2.2 / Ø2.8 / Ø3.2 / Ø3.7 / Ø4.0
Ensure safe drilling by attaching a stopper.
Drill 1 mm shorter than the remaining
maxillary sinus bone.
S-Reamer2
Consist of a total of four types :
Ø2.8 / Ø3.2 / Ø3.6 / Ø3.9
Ensure safe drilling by attaching a stopper.
* 1,200rpm
Diameter(Ø) Product Name
Ø2.2 SAD22
Ø2.8 SAD28
Ø3.2 SAD32
Ø3.7 SAD37
Ø4.0 SAD40
* 1,200rpm
Diameter(Ø) Product Name
Ø2.8 SAR28
Ø3.2 SAR32
Ø3.6 SAR36
Ø3.9 SAR39
Rev.1 07/2015
NB-SAK-IFU-001
The reamer does not hurt the membrane because
during drilling, the bone chip filled the reamer space
so it makes more wide and safe side
Creates a hole of the desired size in the sinus inferior cortical wall without damaging the
sinus mucosa.
Even direct contact with the tool does not cause the sinus membrane to rip. Accordingly,
the membrane is safe even when drilling through the side or the septum.
Bone chips are formed by the end of the S-Reamer’s blade in a flat shape, meaning
that the membrane will not rip, even if there is direct contact with the sinus membrane
Misaligned case Septum
Ø2.8 Ø3.9Ø3.6Ø3.2
Rotary elevator
Head
Bone
Disk
Rotary elevator3
This tool is used to initially remove the mesial and distal membranes immediately after a
hole is formed.
This tool is used to push the bone into the interior and the sides of the sinus after the
bone is inserted into the hole.
* 80rpm
Diameter(Ø) Product Name
Ø2.8 SARE28
Ø3.2 SARE32
Ø3.6 SARE36
Ø3.9 SARE39
Rev.1 07/2015
NB-SAK-IFU-001
Stopper4
Consist of a total of twelve types, from 1 to 12 mm
Used by attaching to a Drill, S-Reamer, Depth
gauge, Bone Condenser, or other tool.
The various stoppers have different colors to prevent
confusion.
When a stopper is attached to a drill, the drill
becomes 0.2 mm longer.
Length
0.2mm
Insert slowly, hugging the wall closely with the tip part.
With both sides of the tip flat, the tip is designed to hook inside
the sinus wall.
Care must be taken not to insert the depth gauge more than 1mm
further than the length of the remaining bone.
Ø2.6
Ø3.1
1 2 3 4 5 6 7 8 9 10 11 12
Bone carrier6
Product Name
SADG01
Product Name
JUMB02
Length 1mm 2mm 3mm 4mm 5mm 6mm 7mm 8mm 9mm 10mm 11mm 12mm
CDS010 CDS020 CDS030 CDS040 CDS050 CDS060 CDS070 CDS080 CDS090 CDS100 CDS110 CDS120Product
Name
Depth gauge5
Tip sizes come in Ø2.6 and Ø3.1
This tool is used to measure the
thickness of the remaining bone.
The depth can be safely verified
when a stopper is attached.
This tool is used to transplant insert the bone inside a sinus hole.
Volume inserted per use: 0.05 cc
Rev.1 07/2015
NB-SAK-IFU-001
Bone condenser7
8-1) Aqua Tap 8-2) Aqua Valve, Hose, Syringe
Syringe
Auqa Value
Hose
<How to Use>
1. After completing drilling towards the Crestal direction, self-tap the
Aqua Tap using a Torque Ratchet for fixation to the bone.
2. Insert the blue rubber part of the Aqua System valve into the head
hole of the Aqua Tap, fixing it.
3. Fill the syringe with the desired amount of physiological saline solution,
then inject slowly.
Product Name
SABC01
Product Name
AQT
Product Name
AQST
Aqua system8
This is a system for detaching sinus membrane that uses water.
Its design is based on a 3 cc syringe; the extent of detachment can be adjusted.
This tool is attached to the bone after a si-
nus hole has been formed in order to allow
water to be safely injected into the sinus.
This tool detaches sinus membrane using
the water inside the syringe.
A set of this tool consists of an aqua
valve, a hose, and a syringe.
Ø1.0
Ø2.2
Rev.1 07/2015
NB-SAK-IFU-001
Rotary elevator
S-reamer
This tool is connected to contra angle type devices, such as a drill or Rotary Elevator, in
order to allow the user to utilize them manually.
Drill Handle9
Product Name
SADH01
9-1) Use as Osteotome
9-2) Use by connecting to a Rotary Elevator or S-Reamer
Possible to use as an osteotome, by connecting a surgical drill to the Drill Handle.
Rev.1 07/2015
NB-SAK-IFU-001
C-guide C-reamer
* 2,000rpm(20:1) / 5,000rpm(1:1)
Ø6.5
Ø6.5 Ø6.5
The C-Reamer is a drill used to create a circular core while forming a bone window in
the lateral wall.
Can be used to drill safely by attaching a stopper.
<Special Characteristics and How to Use>
* 2,000rpm(20:1)
5,000rpm(1:1)
<Lateral Approach Tool Components>
LS-Reamer1
This tool forms a thin bone disk between the reamer and the membrane during lateral
approach and penetrates the lateral wall.
There is a single size—Ø6.5. This tool can be used to drill safely by connecting a Lateral
Stopper.
C-Guide & C-Reamer2
The C-Guide is a guide drill used to prevent slippage and to locate the position ac
curately before use of the C-Reamer.
1. With adequate irrigation, can be used to drill at 2,000 to 5,000 rpm.
2. When creating a lateral hole, prevents sinus membrane damage by forming a thin bone
disk between the sinus membrane and the LS-Reamer.
3. Helps perform the procedure safely by allowing visual observation of the hole as it is
formed, allowing visual identification of special anatomical features, such as blood ves
sels or the septum, in the course of drilling.
Product Name
SALS640
Product Name
SACG610
Product Name
SAC640
Rev.1 07/2015
NB-SAK-IFU-001
Ø3.0
A B
* 1,200rpm
<Window extend>
<Special Characteristics and How to Use >
1. The circular core that is formed by drilling will be 1 mm smaller than the head size of the
C-Reamer. This can be detached from the membrane and stored to be used as a
cover after the procedure.
2. The cutting edges of the C-Reamer are formed on the front and the side, allowing fast
drilling at 2,000 rpm or higher. Sinus membrane damage is minimized because bone
chips are discharged around the cutting edges.
(Because the core tends to become wedged inside the head of the C-Reamer and
spin in place, it is recommended that, after an appropriate amount of drilling, the user
remove the core before it is completely formed, using an Elevator)
This tool is used to initially remove the mesial and the distal membranes immediately after
formation of the hole.
Sinus Elevator3
3-1) Elevator 1
This tool is used to initially remove the mesial and the distal membranes immediately after
formation of the hole.
3-3) Elevator 3
This tool is used to detach any remaining tissue from the deep interior parts.
3-2) Elevator 2
This tool is used after Elevator 1. The hook is used to detach the lower part of the lateral
wall from the hole.
The part with a gentle slant of approximately 30° is used to remove the membranes from
the entire sinus floor and from the medial and posterior walls.
Product Name
SLE01
Product Name
SLE02
Product Name
SLE03
Product Name
SCT30
Side cutter4
This tool is used laterally to widen a hole formed using the LS-Reamer or the C-Reamer.
It comes in one size : Ø3.0
Rev.1 07/2015
NB-SAK-IFU-001
A : 0.7mm
A : Stopper Length
B : Length
C : 1.5mm
Short Long
Lateral stopper5
Consist of a total of four sizes: 1 to 4 mm
Use after connecting to the LS-Reamer,
C-Reamer, Side Cutter, or other
components.
When a stopper is connected to the LS-
Reamer or the C-Reamer, those tools will
be lengthened by 0.7 mm.
When a stopper is attached to the Side
Cutter, the latter tool will be lengthened
by 1.5 mm.
Length 1mm 2mm 3mm 4mm
LTS010 LTS020 LTS030 LTS040Product
Name
<Implant Placement Tool Components>
Fixture driver1
This tool is used to implant the fixture
It includes two types of ratchets and one type of contra angle.
Length Product name
Ratchet (Short) ISFD10R
Ratchet (Long) ISFD15R
Contra Angle ISFD05C
Product name
HD1215S
Product name
TW60
This tool is used to connect the cover screw, Healing Abutment, Abutment screw, and
other components to the implant.
Hex driver2
This tool is used by connecting to a type of ratchet when emplanting or applying torque
to an implant.
Torque wrench3
15mm
Hex 1.2
Rev.1 07/2015
NB-SAK-IFU-001
How to Sterilize
In order to effectively carry out high-pressure steam sterilization, the use of biological indicators at a regular
interval must be considered. (Dry heat sterilization or chemical sterilization is not recommended.)
① Minimum time and temperature conditions for steam sterilization to reach the sterilization guarantee level
of 10
-6
② If regional or national sterilization requirements are stricter than the conditions provided above, they must
be followed.
If the above sterilization conditions are exceeded, it is possible that the plastic and components may be
damaged. The sterilization device must be adjusted to ensure that the recommended temperatures are
not exceeded.
Cycle Type Temperature Pressure Dry Time
KIT,
Instrument
Pre-vacuum¹²
132 ℃ 2 bars
3 minutes 30 minutes
270 °F 28.5 psi
KIT,
Instrument
Gravity¹
121 ℃ 1 bars
40 minutes 30 minutes
250 °F 14.5 psi
Exposure
Time
<Recommended Steam Sterilization Conditions >
Because the product is a non-sterilized medical device, select either a pre-vacuum or a
gravity autoclave. (Plastic products must not be sterilized at or above 170°C (338°F)
Before sterilization, the inner wrapper must be removed from the tray. Assembled compo-
nents must be separated in order to improve the efficiency of sterilization.
Using surgical wrap, wrap the tray, seal with autoclave tape, and sterilize.
1
2
3
Surgical Tools
1
2
3
4
After the procedure ends, detach all surgical tools from the tray, soak them in alcohol, and
rinse them using conventional means.
After washing by using distilled water or flowing water and rinsing, remove any traces of
blood or foreign objects remaining. Use a syringe or pipe cleaner for areas that are difficult
to wash.
Following the instructions of the cleaner manufacturer, dilute the enzyme cleaner using
tap water and, after ten minutes of ultrasound washing, rinse using tap water for three
minutes.
Completely remove the moisture using a dry cloth or a warm-air circulator.
KIT Tray
1
2
3
Remove all visible foreign objects using distilled water or flowing water and a soft brush. For
areas that are difficult to clean, use a syringe or pipe cleaner.
Following the instructions of the cleaner manufacturer, dilute the enzyme cleaner using tap
water and soak for one minute. Afterwards, using a soft brush, remove any foreign objects
remaining on any part.
After washing, rinse for three minutes using tap water to remove the remaining enzyme
cleaner.
How to Wash after Use
Rev.1 07/2015
NB-SAK-IFU-001
4
5
Completely remove the moisture using a dry cloth or a warm-air circulator.
Organize the dry surgical tools in the kit case and sterilize, following the sterilization proce-
dure. (At this time, refer to the colors to make the setup easy.)
1
2
3
All surgical tools that were used must be immediately detached, washed, and dried, after
the procedure, then stored at room temperature.
Do not store in a soiled area or where there is a risk of infection.
This product is a non-sterilized medical device. Accordingly, it may be used only after
sterilizing in an autoclave before and after any procedure. (See How to Sterilize)
How to Store and Maintain after Use
1
2
3
4
5
6
7
Only dentists who have completed implant procedure education and training courses can
use this product.
For each patient, a procedure plan must be established, based on a treatment plan after
testing and analyzing for whole-body ailments, infectious disease, whether they are receiv-
ing treatment for other ailments, and whether there is any oral lesion.
The surgeon must use the product only after becoming completely familiar with how to
use the product and the relevant warnings, and must select products that fit the treat-
ment plan.
Before each procedure, the tools must be examined for wear and tear.
Any external contact with the surfaces is prohibited.
Improper selection of the patient or procedure may cause failure of the implant or post-
surgical bone loss around the implant.
Hydrogen peroxide is prohibited for disinfection and washing, as it could damage or dis-
color the TIN coating, laser markings, or colors.
Precaution
1
2
3
4
5
6
7
Patients with serious internal ailments: endocrinal ailments such as diabetes or hyperten-
sion, circulatory ailments, and ailments related to the blood, organ, or immune systems.
Patients receiving high-level radiation treatment for malignant tumors or other reasons.
Patients who have unsuitable jaw relations or problematic occlusions.
Patients with dry mouths.
Patients with unrestored teeth who maintain bad oral health conditions.
Patients with acute inflammatory ailments and patients who are at risk of infection.
Pregnant patients.
Contraindication
Rev.1 07/2015
NB-SAK-IFU-001
11
12
13
14
15
16
8
10
9
Smokers.
Patients with blood clotting conditions or with severe cardiac ailments.
Children aged 16 years or younger.
Patients who are allergic to titanium or stainless steel.
Patients without ordinary wound-healing function.
Patients who are taking other drugs.
Patients who are vulnerable to physical and mental stress due to temporary use of a spe-
cific medication.
Patients who are emotionally unstable, such as due to alcohol addition, drug abuse, neuro-
logical ailments, or mental ailments.
Patients who have unrealistic expectations regarding the treatment.
1
2
3
Using surgical techniques in a skillful manner minimizes the occurrence of complications.
Paresthesia due to nerve damage or malocclusion, infection, edema, hypodermic bleed-
ing, pain, or opening of the sutures, ulcer in the soft tissues, and other localized adverse
reactions may occur.
Localized and general allergic reactions.
Side effect
Rev.1 07/2015
NB-SAK-IFU-001
* This product is a non-sterilized medical device.
Label Symbols
Symbol Definition Symbol Definition
Catalog Number
Consult instruction
for use
Batch Code
Sterilized Using
irradiation
Date of manufacture Prescription Only
Manufacturer Do not re-use
Caution, consult
accompanying
documents
Do not use if
package is damaged
Non-Sterile
Rev.1 07/2015
NB-SAK-IFU-001
Manufacturer /Distributor : Neobiotech Co., Ltd. www.neobiotech.co.kr
104, 24 / 102, 103, 104-1, 104-2, 105, 106, 205, 212, 312, 509, 510, 511, 10F
36 Digital-ro 27-Gil, Guro-Gu, Seoul, Korea Tel. +82 2 582 2885 Fax. +82 2 582 2883

More Related Content

PDF
ACM user guide
PDF
Sca user guide
PDF
Clinical case SR Kit with Movie
PDF
2015 CMI IT implant catalog
PDF
IS II active Catalog
PDF
Sr 2 kit version 01
PDF
FR Kit user guide
PDF
2015 CMI IS implant catalog
ACM user guide
Sca user guide
Clinical case SR Kit with Movie
2015 CMI IT implant catalog
IS II active Catalog
Sr 2 kit version 01
FR Kit user guide
2015 CMI IS implant catalog

What's hot (20)

PDF
S mini implant catalog (2015)
PDF
User guide universal prosthetic kit -151207
PDF
Sla user guide
PDF
2015 CMI EB catalog
PDF
Neobiotech implant system (2015.02)
PDF
CTi mem new version 01
PDF
GBR Kit catalog
PDF
Prosthetic guide - 151210 update
PDF
Flow-FX Flow Screw ~ Surgical Technique Guide
PDF
Eb catalog
DOC
HOT Screen Spare Parts & Maintenance
PDF
20151021 CAMELEON 5AXIS
PDF
Eagle Composite Hose - Petroleum Hose - Fluid Transfer hose
PDF
Webtools WCOS54D (open sided) Wire Rope Cutters up to 54mm - Operation Manual
PDF
Orbit valves-brochure
PDF
Split Rotary Seals Brochure Small
PPTX
Ansi z359 2017
PDF
microseal-acetabular-system
PDF
T308 epoxy-summary-brochure-1299505
PDF
Pipe flange bolting guide
S mini implant catalog (2015)
User guide universal prosthetic kit -151207
Sla user guide
2015 CMI EB catalog
Neobiotech implant system (2015.02)
CTi mem new version 01
GBR Kit catalog
Prosthetic guide - 151210 update
Flow-FX Flow Screw ~ Surgical Technique Guide
Eb catalog
HOT Screen Spare Parts & Maintenance
20151021 CAMELEON 5AXIS
Eagle Composite Hose - Petroleum Hose - Fluid Transfer hose
Webtools WCOS54D (open sided) Wire Rope Cutters up to 54mm - Operation Manual
Orbit valves-brochure
Split Rotary Seals Brochure Small
Ansi z359 2017
microseal-acetabular-system
T308 epoxy-summary-brochure-1299505
Pipe flange bolting guide
Ad

Viewers also liked (13)

PDF
2015 Company & Product Introduction
PDF
NeoBiotech - FR kit user guide
PDF
Peri implant treatment Step
PDF
20160222 Neobiotech article collection.
PDF
SCA Kit case(Neobiotech)
PDF
Neo surgical accessory kit
PDF
201601001 Guide seminar
PDF
IS II active implant protocol(Neobiotech)
PPT
Mini implants
PDF
Zirconium for dental implant restoration
PPTX
Orthodontic implants
PPTX
Temporary anchorage devices in orthodontics
PDF
10 New Business Models for this Decade
2015 Company & Product Introduction
NeoBiotech - FR kit user guide
Peri implant treatment Step
20160222 Neobiotech article collection.
SCA Kit case(Neobiotech)
Neo surgical accessory kit
201601001 Guide seminar
IS II active implant protocol(Neobiotech)
Mini implants
Zirconium for dental implant restoration
Orthodontic implants
Temporary anchorage devices in orthodontics
10 New Business Models for this Decade
Ad

Similar to 20150827 user guide (sinus all) (20)

PDF
Osung catalogue 2013
PDF
Brochure mini fragment
PDF
Arsenal Ankle Plating System - Implant Materials | Indications | Contraindica...
PDF
4 small fragment
PPTX
Perio. instrumentation
DOC
B m p/ rotary endodontic courses by indian dental academy
PDF
Biotec Dental Implants One Piece ARP Catalogue 2019
PPTX
Implant armamentarium
PDF
Implant catalog copia
PDF
EM 2019 Catalog
PDF
MAT - Proximal Femur Plate
PPTX
Proximal Femoral Reconstruction N surgi.pptx
PDF
Tplo Tibial Plateau Leveling Osteotomy) surgical instruments
PPT
Abutments design & selection /orthodontics training courses
PDF
IRJET- Design and Development of Collet Chuck
PDF
PDF
ERIKS Stanley Black and Decker Product Brochure
PPTX
Surgical technique for gama nail
PPT
Abutments/ dental implant courses
Osung catalogue 2013
Brochure mini fragment
Arsenal Ankle Plating System - Implant Materials | Indications | Contraindica...
4 small fragment
Perio. instrumentation
B m p/ rotary endodontic courses by indian dental academy
Biotec Dental Implants One Piece ARP Catalogue 2019
Implant armamentarium
Implant catalog copia
EM 2019 Catalog
MAT - Proximal Femur Plate
Proximal Femoral Reconstruction N surgi.pptx
Tplo Tibial Plateau Leveling Osteotomy) surgical instruments
Abutments design & selection /orthodontics training courses
IRJET- Design and Development of Collet Chuck
ERIKS Stanley Black and Decker Product Brochure
Surgical technique for gama nail
Abutments/ dental implant courses

More from Kei Lim (15)

PDF
User guide NEO GUIDE SYSTEM - 20160621
PDF
20160626 symposium leaflet v04
PDF
Any time loading proof leaflet 151217
PDF
Predictable and Accurate 3D Guided implant placement for a 3-D world
PDF
2015 NEOBIOTECH CADCAM SYSTEM
PDF
ACM poster from Michigan University
PDF
Live surgery Sketch
PDF
20150925 jin y kim basic
PDF
CAMELEON CS (Chairside milling)
PDF
Neo guide system_201505_ver04
PDF
Prosthetic guide leaflet
PDF
Clinical case (ibrush)
PDF
CADCAM system
PDF
20150625 tijuana Implant live surgery
PDF
Smiler ITS Live Surgery Course
User guide NEO GUIDE SYSTEM - 20160621
20160626 symposium leaflet v04
Any time loading proof leaflet 151217
Predictable and Accurate 3D Guided implant placement for a 3-D world
2015 NEOBIOTECH CADCAM SYSTEM
ACM poster from Michigan University
Live surgery Sketch
20150925 jin y kim basic
CAMELEON CS (Chairside milling)
Neo guide system_201505_ver04
Prosthetic guide leaflet
Clinical case (ibrush)
CADCAM system
20150625 tijuana Implant live surgery
Smiler ITS Live Surgery Course

Recently uploaded (20)

PPTX
Neuropathic pain.ppt treatment managment
PPTX
ANATOMY OF MEDULLA OBLANGATA AND SYNDROMES.pptx
PPTX
Acid Base Disorders educational power point.pptx
PPTX
Clinical approach and Radiotherapy principles.pptx
PPTX
1. Basic chemist of Biomolecule (1).pptx
PPT
nephrology MRCP - Member of Royal College of Physicians ppt
PPTX
obstructive neonatal jaundice.pptx yes it is
PDF
TISSUE LECTURE (anatomy and physiology )
PPTX
vertigo topics for undergraduate ,mbbs/md/fcps
PPTX
MANAGEMENT SNAKE BITE IN THE TROPICALS.pptx
PPT
Rheumatology Member of Royal College of Physicians.ppt
PPTX
NRPchitwan6ab2802f9.pptxnepalindiaindiaindiapakistan
PPTX
Acute Coronary Syndrome for Cardiology Conference
PPTX
preoerative assessment in anesthesia and critical care medicine
PPT
STD NOTES INTRODUCTION TO COMMUNITY HEALT STRATEGY.ppt
PPT
Obstructive sleep apnea in orthodontics treatment
DOCX
PEADIATRICS NOTES.docx lecture notes for medical students
PDF
SEMEN PREPARATION TECHNIGUES FOR INTRAUTERINE INSEMINATION.pdf
PDF
Extended-Expanded-role-of-Nurses.pdf is a key for student Nurses
PDF
Intl J Gynecology Obste - 2021 - Melamed - FIGO International Federation o...
Neuropathic pain.ppt treatment managment
ANATOMY OF MEDULLA OBLANGATA AND SYNDROMES.pptx
Acid Base Disorders educational power point.pptx
Clinical approach and Radiotherapy principles.pptx
1. Basic chemist of Biomolecule (1).pptx
nephrology MRCP - Member of Royal College of Physicians ppt
obstructive neonatal jaundice.pptx yes it is
TISSUE LECTURE (anatomy and physiology )
vertigo topics for undergraduate ,mbbs/md/fcps
MANAGEMENT SNAKE BITE IN THE TROPICALS.pptx
Rheumatology Member of Royal College of Physicians.ppt
NRPchitwan6ab2802f9.pptxnepalindiaindiaindiapakistan
Acute Coronary Syndrome for Cardiology Conference
preoerative assessment in anesthesia and critical care medicine
STD NOTES INTRODUCTION TO COMMUNITY HEALT STRATEGY.ppt
Obstructive sleep apnea in orthodontics treatment
PEADIATRICS NOTES.docx lecture notes for medical students
SEMEN PREPARATION TECHNIGUES FOR INTRAUTERINE INSEMINATION.pdf
Extended-Expanded-role-of-Nurses.pdf is a key for student Nurses
Intl J Gynecology Obste - 2021 - Melamed - FIGO International Federation o...

20150827 user guide (sinus all)

  • 2. Rev.1 07/2015 NB-SAK-IFU-001 Sinus Elevator SCA Kit SLA Kit + + Surgical Kit Neo SinusAll Kit This product is a SinusAll Kit, consisting of dental implant surgical tools (drills, surgical tools, and drivers) made out of medical grade materials, including stainless steel. Product description The SinusAll Kit combines NeoBiotech’s SCA (Sinus Crestal Approach) Kit, SLA (Sinus Lateral Approach) Kit, and the Surgical Kit into a single kit. The product allows maxillary sinus implant procedures to take place using a single kit, rather than having to prepare a sinus kit and a surgical kit separately. Intended use
  • 3. Rev.1 07/2015 NB-SAK-IFU-001 Ø2.0 Ø4.0Ø3.7Ø3.2Ø2.8 12.0 11.0 10.0 9.0 8.0 7.0 6.0 5.0 4.0 3.0 2.0 1.0 0.0 0.2 Ø2.8 Ø3.9Ø3.6Ø3.2 Store at room temperature in a dry location away from direct light. Preservation 1 2 3 4 Prior to using this product, the clinician must completely understand the condition, perfor- mance, and function of the product. Use only after raising any doubts and verifying any issues with the manufacturer. For the procedure, a plan must be first established, based on checking the patient’s oral condition and accurate judgments. After taking into consideration the condition of the patient, tools appropriate for the proce- dure must be prepared. How to Prepare Before Use <Crestal Approach Tool Components> Components Surgical Drill1 Consist of a total of five types : Ø2.2 / Ø2.8 / Ø3.2 / Ø3.7 / Ø4.0 Ensure safe drilling by attaching a stopper. Drill 1 mm shorter than the remaining maxillary sinus bone. S-Reamer2 Consist of a total of four types : Ø2.8 / Ø3.2 / Ø3.6 / Ø3.9 Ensure safe drilling by attaching a stopper. * 1,200rpm Diameter(Ø) Product Name Ø2.2 SAD22 Ø2.8 SAD28 Ø3.2 SAD32 Ø3.7 SAD37 Ø4.0 SAD40 * 1,200rpm Diameter(Ø) Product Name Ø2.8 SAR28 Ø3.2 SAR32 Ø3.6 SAR36 Ø3.9 SAR39
  • 4. Rev.1 07/2015 NB-SAK-IFU-001 The reamer does not hurt the membrane because during drilling, the bone chip filled the reamer space so it makes more wide and safe side Creates a hole of the desired size in the sinus inferior cortical wall without damaging the sinus mucosa. Even direct contact with the tool does not cause the sinus membrane to rip. Accordingly, the membrane is safe even when drilling through the side or the septum. Bone chips are formed by the end of the S-Reamer’s blade in a flat shape, meaning that the membrane will not rip, even if there is direct contact with the sinus membrane Misaligned case Septum Ø2.8 Ø3.9Ø3.6Ø3.2 Rotary elevator Head Bone Disk Rotary elevator3 This tool is used to initially remove the mesial and distal membranes immediately after a hole is formed. This tool is used to push the bone into the interior and the sides of the sinus after the bone is inserted into the hole. * 80rpm Diameter(Ø) Product Name Ø2.8 SARE28 Ø3.2 SARE32 Ø3.6 SARE36 Ø3.9 SARE39
  • 5. Rev.1 07/2015 NB-SAK-IFU-001 Stopper4 Consist of a total of twelve types, from 1 to 12 mm Used by attaching to a Drill, S-Reamer, Depth gauge, Bone Condenser, or other tool. The various stoppers have different colors to prevent confusion. When a stopper is attached to a drill, the drill becomes 0.2 mm longer. Length 0.2mm Insert slowly, hugging the wall closely with the tip part. With both sides of the tip flat, the tip is designed to hook inside the sinus wall. Care must be taken not to insert the depth gauge more than 1mm further than the length of the remaining bone. Ø2.6 Ø3.1 1 2 3 4 5 6 7 8 9 10 11 12 Bone carrier6 Product Name SADG01 Product Name JUMB02 Length 1mm 2mm 3mm 4mm 5mm 6mm 7mm 8mm 9mm 10mm 11mm 12mm CDS010 CDS020 CDS030 CDS040 CDS050 CDS060 CDS070 CDS080 CDS090 CDS100 CDS110 CDS120Product Name Depth gauge5 Tip sizes come in Ø2.6 and Ø3.1 This tool is used to measure the thickness of the remaining bone. The depth can be safely verified when a stopper is attached. This tool is used to transplant insert the bone inside a sinus hole. Volume inserted per use: 0.05 cc
  • 6. Rev.1 07/2015 NB-SAK-IFU-001 Bone condenser7 8-1) Aqua Tap 8-2) Aqua Valve, Hose, Syringe Syringe Auqa Value Hose <How to Use> 1. After completing drilling towards the Crestal direction, self-tap the Aqua Tap using a Torque Ratchet for fixation to the bone. 2. Insert the blue rubber part of the Aqua System valve into the head hole of the Aqua Tap, fixing it. 3. Fill the syringe with the desired amount of physiological saline solution, then inject slowly. Product Name SABC01 Product Name AQT Product Name AQST Aqua system8 This is a system for detaching sinus membrane that uses water. Its design is based on a 3 cc syringe; the extent of detachment can be adjusted. This tool is attached to the bone after a si- nus hole has been formed in order to allow water to be safely injected into the sinus. This tool detaches sinus membrane using the water inside the syringe. A set of this tool consists of an aqua valve, a hose, and a syringe. Ø1.0 Ø2.2
  • 7. Rev.1 07/2015 NB-SAK-IFU-001 Rotary elevator S-reamer This tool is connected to contra angle type devices, such as a drill or Rotary Elevator, in order to allow the user to utilize them manually. Drill Handle9 Product Name SADH01 9-1) Use as Osteotome 9-2) Use by connecting to a Rotary Elevator or S-Reamer Possible to use as an osteotome, by connecting a surgical drill to the Drill Handle.
  • 8. Rev.1 07/2015 NB-SAK-IFU-001 C-guide C-reamer * 2,000rpm(20:1) / 5,000rpm(1:1) Ø6.5 Ø6.5 Ø6.5 The C-Reamer is a drill used to create a circular core while forming a bone window in the lateral wall. Can be used to drill safely by attaching a stopper. <Special Characteristics and How to Use> * 2,000rpm(20:1) 5,000rpm(1:1) <Lateral Approach Tool Components> LS-Reamer1 This tool forms a thin bone disk between the reamer and the membrane during lateral approach and penetrates the lateral wall. There is a single size—Ø6.5. This tool can be used to drill safely by connecting a Lateral Stopper. C-Guide & C-Reamer2 The C-Guide is a guide drill used to prevent slippage and to locate the position ac curately before use of the C-Reamer. 1. With adequate irrigation, can be used to drill at 2,000 to 5,000 rpm. 2. When creating a lateral hole, prevents sinus membrane damage by forming a thin bone disk between the sinus membrane and the LS-Reamer. 3. Helps perform the procedure safely by allowing visual observation of the hole as it is formed, allowing visual identification of special anatomical features, such as blood ves sels or the septum, in the course of drilling. Product Name SALS640 Product Name SACG610 Product Name SAC640
  • 9. Rev.1 07/2015 NB-SAK-IFU-001 Ø3.0 A B * 1,200rpm <Window extend> <Special Characteristics and How to Use > 1. The circular core that is formed by drilling will be 1 mm smaller than the head size of the C-Reamer. This can be detached from the membrane and stored to be used as a cover after the procedure. 2. The cutting edges of the C-Reamer are formed on the front and the side, allowing fast drilling at 2,000 rpm or higher. Sinus membrane damage is minimized because bone chips are discharged around the cutting edges. (Because the core tends to become wedged inside the head of the C-Reamer and spin in place, it is recommended that, after an appropriate amount of drilling, the user remove the core before it is completely formed, using an Elevator) This tool is used to initially remove the mesial and the distal membranes immediately after formation of the hole. Sinus Elevator3 3-1) Elevator 1 This tool is used to initially remove the mesial and the distal membranes immediately after formation of the hole. 3-3) Elevator 3 This tool is used to detach any remaining tissue from the deep interior parts. 3-2) Elevator 2 This tool is used after Elevator 1. The hook is used to detach the lower part of the lateral wall from the hole. The part with a gentle slant of approximately 30° is used to remove the membranes from the entire sinus floor and from the medial and posterior walls. Product Name SLE01 Product Name SLE02 Product Name SLE03 Product Name SCT30 Side cutter4 This tool is used laterally to widen a hole formed using the LS-Reamer or the C-Reamer. It comes in one size : Ø3.0
  • 10. Rev.1 07/2015 NB-SAK-IFU-001 A : 0.7mm A : Stopper Length B : Length C : 1.5mm Short Long Lateral stopper5 Consist of a total of four sizes: 1 to 4 mm Use after connecting to the LS-Reamer, C-Reamer, Side Cutter, or other components. When a stopper is connected to the LS- Reamer or the C-Reamer, those tools will be lengthened by 0.7 mm. When a stopper is attached to the Side Cutter, the latter tool will be lengthened by 1.5 mm. Length 1mm 2mm 3mm 4mm LTS010 LTS020 LTS030 LTS040Product Name <Implant Placement Tool Components> Fixture driver1 This tool is used to implant the fixture It includes two types of ratchets and one type of contra angle. Length Product name Ratchet (Short) ISFD10R Ratchet (Long) ISFD15R Contra Angle ISFD05C Product name HD1215S Product name TW60 This tool is used to connect the cover screw, Healing Abutment, Abutment screw, and other components to the implant. Hex driver2 This tool is used by connecting to a type of ratchet when emplanting or applying torque to an implant. Torque wrench3 15mm Hex 1.2
  • 11. Rev.1 07/2015 NB-SAK-IFU-001 How to Sterilize In order to effectively carry out high-pressure steam sterilization, the use of biological indicators at a regular interval must be considered. (Dry heat sterilization or chemical sterilization is not recommended.) ① Minimum time and temperature conditions for steam sterilization to reach the sterilization guarantee level of 10 -6 ② If regional or national sterilization requirements are stricter than the conditions provided above, they must be followed. If the above sterilization conditions are exceeded, it is possible that the plastic and components may be damaged. The sterilization device must be adjusted to ensure that the recommended temperatures are not exceeded. Cycle Type Temperature Pressure Dry Time KIT, Instrument Pre-vacuum¹² 132 ℃ 2 bars 3 minutes 30 minutes 270 °F 28.5 psi KIT, Instrument Gravity¹ 121 ℃ 1 bars 40 minutes 30 minutes 250 °F 14.5 psi Exposure Time <Recommended Steam Sterilization Conditions > Because the product is a non-sterilized medical device, select either a pre-vacuum or a gravity autoclave. (Plastic products must not be sterilized at or above 170°C (338°F) Before sterilization, the inner wrapper must be removed from the tray. Assembled compo- nents must be separated in order to improve the efficiency of sterilization. Using surgical wrap, wrap the tray, seal with autoclave tape, and sterilize. 1 2 3 Surgical Tools 1 2 3 4 After the procedure ends, detach all surgical tools from the tray, soak them in alcohol, and rinse them using conventional means. After washing by using distilled water or flowing water and rinsing, remove any traces of blood or foreign objects remaining. Use a syringe or pipe cleaner for areas that are difficult to wash. Following the instructions of the cleaner manufacturer, dilute the enzyme cleaner using tap water and, after ten minutes of ultrasound washing, rinse using tap water for three minutes. Completely remove the moisture using a dry cloth or a warm-air circulator. KIT Tray 1 2 3 Remove all visible foreign objects using distilled water or flowing water and a soft brush. For areas that are difficult to clean, use a syringe or pipe cleaner. Following the instructions of the cleaner manufacturer, dilute the enzyme cleaner using tap water and soak for one minute. Afterwards, using a soft brush, remove any foreign objects remaining on any part. After washing, rinse for three minutes using tap water to remove the remaining enzyme cleaner. How to Wash after Use
  • 12. Rev.1 07/2015 NB-SAK-IFU-001 4 5 Completely remove the moisture using a dry cloth or a warm-air circulator. Organize the dry surgical tools in the kit case and sterilize, following the sterilization proce- dure. (At this time, refer to the colors to make the setup easy.) 1 2 3 All surgical tools that were used must be immediately detached, washed, and dried, after the procedure, then stored at room temperature. Do not store in a soiled area or where there is a risk of infection. This product is a non-sterilized medical device. Accordingly, it may be used only after sterilizing in an autoclave before and after any procedure. (See How to Sterilize) How to Store and Maintain after Use 1 2 3 4 5 6 7 Only dentists who have completed implant procedure education and training courses can use this product. For each patient, a procedure plan must be established, based on a treatment plan after testing and analyzing for whole-body ailments, infectious disease, whether they are receiv- ing treatment for other ailments, and whether there is any oral lesion. The surgeon must use the product only after becoming completely familiar with how to use the product and the relevant warnings, and must select products that fit the treat- ment plan. Before each procedure, the tools must be examined for wear and tear. Any external contact with the surfaces is prohibited. Improper selection of the patient or procedure may cause failure of the implant or post- surgical bone loss around the implant. Hydrogen peroxide is prohibited for disinfection and washing, as it could damage or dis- color the TIN coating, laser markings, or colors. Precaution 1 2 3 4 5 6 7 Patients with serious internal ailments: endocrinal ailments such as diabetes or hyperten- sion, circulatory ailments, and ailments related to the blood, organ, or immune systems. Patients receiving high-level radiation treatment for malignant tumors or other reasons. Patients who have unsuitable jaw relations or problematic occlusions. Patients with dry mouths. Patients with unrestored teeth who maintain bad oral health conditions. Patients with acute inflammatory ailments and patients who are at risk of infection. Pregnant patients. Contraindication
  • 13. Rev.1 07/2015 NB-SAK-IFU-001 11 12 13 14 15 16 8 10 9 Smokers. Patients with blood clotting conditions or with severe cardiac ailments. Children aged 16 years or younger. Patients who are allergic to titanium or stainless steel. Patients without ordinary wound-healing function. Patients who are taking other drugs. Patients who are vulnerable to physical and mental stress due to temporary use of a spe- cific medication. Patients who are emotionally unstable, such as due to alcohol addition, drug abuse, neuro- logical ailments, or mental ailments. Patients who have unrealistic expectations regarding the treatment. 1 2 3 Using surgical techniques in a skillful manner minimizes the occurrence of complications. Paresthesia due to nerve damage or malocclusion, infection, edema, hypodermic bleed- ing, pain, or opening of the sutures, ulcer in the soft tissues, and other localized adverse reactions may occur. Localized and general allergic reactions. Side effect
  • 14. Rev.1 07/2015 NB-SAK-IFU-001 * This product is a non-sterilized medical device. Label Symbols Symbol Definition Symbol Definition Catalog Number Consult instruction for use Batch Code Sterilized Using irradiation Date of manufacture Prescription Only Manufacturer Do not re-use Caution, consult accompanying documents Do not use if package is damaged Non-Sterile
  • 16. Manufacturer /Distributor : Neobiotech Co., Ltd. www.neobiotech.co.kr 104, 24 / 102, 103, 104-1, 104-2, 105, 106, 205, 212, 312, 509, 510, 511, 10F 36 Digital-ro 27-Gil, Guro-Gu, Seoul, Korea Tel. +82 2 582 2885 Fax. +82 2 582 2883