AMOS - COMMANDLINE INTERFACE
1. GETTING STARTED
1.1 LAUNCHING AMOS FROM OSS FRONT PAGE GUI
AMOS MOSHELL SESSION IS OPEN DEFAULT FROM USER HOME DIRECTORY IN OSS.
1.2 LAUNCHING AMOS FROM OSS ONE/ OSS NETWORK EXPLORER
THE AMOS SESSION DIRECTLY OPENED INTO R021E NODE.
2. USING AMOS
2.1 THESE ARE THE IP ADDRESSES OF THE RNC .
RNC IP ADDRESS PASSWORD
R021E 10.10.121.133 rnc@1234
R031E 10.17.121.133 rnc@1234
R041E 10.11.121.133 rnc@1234
R051E 10.18.121.133 rnc@1234
R061E 10.8.121.133 rnc@1234
R071E 10.14.121.133 rnc@1234
2.2 AMOS SESSION
USER MAY USE NODE DNS NAME OR IP ADDRESS TO CONNECT TO THE NODE.
WHEN THE IP CONTACT IS OK, BOTH IS ACCESSIBLE.
2.2.1 PLEASE USER SMALL LETTER FOR command initiation throughout the AMOS SESSION.
amos R021E or amos 10.10.121.133
2.2.2 IP Addresses are used when the OSS does not define the updated Node DNS with its IP
Address.
2.2.3 After amos R021E, user must send command “lt all”.
This will refresh and load all MO’s information into the session.
User may notice that for the “amos 10.10.121.133” the effect “lt all”, will later on read the
node userlabel to be R021E.
2.2.4 Command to be used in the RNC session
1. Alarm checking in RNC
alt - Alarm list with time
ala - Alarm list in detail information
alc - Alar list in comma separated value. Useful to import in excel
format
2. Checking NodeB in RNC
lst <NodeB ID>
Normally, Site ID is starting with 2 alphabets follow by 4 digits.
To check all subordinate of a cell, use “lst”.
To check the main element use, ‘st”
To see all site listing in the related RNC, use “str”
To have site listing in CSV format, use “str <any label>”, it will create the file csv format and
need to be transferred from OSS your user folder into your laptop and can be open in excel file
as sample below.
R021E> str UI0401
Output saved to CSV file: UI0401
R021E> !ls UI0401*
UI0401
R021E> !pwd
/home/nakzaidi
File sample after excel extraction:
2014-17-12 Update of command “str”
The implementation of 2nd
carrier has cause some confusion to the output command “str”.
It register the fully operational site as only 1 site and the rest, in under the second category –
totally or partially unavailable.
This is due to the 1st
carrier utrancells are fully operational and 2nd
carrier utrancells are
LOCKED.
The recommendation given to the issue is to monitor closely the red marker CELLNAMES
column.
Detail information here:
Columns:
MOD: this the RNC module that the site is defined in.
IUBLINK: this is the identity of the iublink that the site is using.
CELLNAME: this is the name of the cells that are connected to that IubLink.
the cell names correspond to the respective sectors.
eg: 6306-1/2/3 means that: cell 63061 is connected to SECT1
cell 63062 is connected to SECT2
cell 63063 is connected to SECT3.
CFRPHEM: the first digit is the state of the UtranCell.
the three following digits are the state of the common channels (Fach/Rach/Pch).
the fifth digit (if present) represents the state of the hsdpa channel (Hsdsch).
the sixth digit (if present) represents the state of the enhanced uplink channel (Eul).
the seventh digit (if present) represents the state of the Mbms channel (MbmsCch).
ICDS: the first digit is the state of the IubLink
the second digit is the state of NbapCommon
the third digit is the state of NbapDedicated
Up to P5, the final two digits are the states of NodeSynchTp 1 and 2.
From P6, the final digit is the state of NodeSynch.
TN: The type of transport network used by the IubLink. A=ATM, I=IP, AI=DualStack
States:
- L = Locked
- S = ShuttingDown
- 0 = Unlocked & Disabled
- 1 = Unlocked & Enabled
Please concentrate on the highlighted column only.
3. Blocking/Deblocking a NodeB
To block an utrancell only.
The same when doing with command “bl <utrancell id>”
Also the same when “bl <proxy no>”
To block a site, use “bl <site id>” or “lbl <site id>”
4. Checking NodeB downtime from the log in RNC
-s startdate
lga Alarm log only
lgaj Alarm log with duration.
M* Alarm initiated with Major severity and “*” alarm cease.
5. Checking RNC hardware
“st plug” - listing of main EPB1 board carry NodeB, Ranap,Rnsap traffic
“cabx” - hardware information on board name, serial number, Temperature
In RNC, Slot=3 and Slot=25 is the main controlling board, one in Active and another one must
be in StandbyReady mode. It shown in “cabx” command.
Alarm temperature will trigger if more than 85 Celsius.
R021E> cabx
141213-12:51:16 10.10.121.133 10.0n RNC_NODE_MODEL_U_1_2679 stopfile=/tmp/1411
Please enter Node Password:
...........put /var/opt/ericsson/amos/moshell_logfiles/nakzaidi/logs_moshell/tempfiles/20141213-
113430_1203/lhCmd1411 /d/usr/lhCmd1411 ... OK
.........put /var/opt/ericsson/amos/moshell_logfiles/nakzaidi/logs_moshell/tempfiles/20141213-
113430_1203/lhCmd1411 /d/usr/lhCmd1411 ... OK
===============================================================================================================
=
SMN APN BOARD FAULT OPER MAINT FRO PRODUCTNUMBER REV SERIAL DATE TEMP COREMGR
===============================================================================================================
=
0 1 SCXB3 OFF ON OFF 2 ROJ208395/1 R6B A065078545 20131120
0 2 CMXB3 OFF ON OFF 20 ROJ208392/1 R7D A065083927 20131129
0 3 EPB1 OFF ON OFF 1 ROJ208394/1 R1D CA71543572 20131101 +58C StandbyReady*
0 4 EPB1 OFF ON OFF 5 ROJ208394/1 R1D CA71543575 20131101 +59C
0 5 EPB1 OFF ON OFF 8 ROJ208394/1 R1D CA71543609 20131101 +57C
0 6 EPB1 OFF ON OFF 25 ROJ208394/1 R1D CA71543554 20131101 +62C
0 7 EPB1 OFF ON OFF 14 ROJ208394/1 R1D CA71543616 20131101 +60C
0 8 EPB1 OFF ON OFF 11 ROJ208394/1 R1D CA71543574 20131101 +61C
0 10 EPB1 OFF ON OFF 17 ROJ208394/1 R1D CA71543555 20131101 +56C
0 11 EVOET OFF ON OFF 21 ROJ208467/1 R1E A065082733 20131127 +71C
0 12 EPB1 OFF ON OFF 40 ROJ208394/1 R1D CA71543571 20131101 +59C
0 13 EPB1 OFF ON OFF 37 ROJ208394/1 R1D CA71535377 20131029 +62C
0 14 EPB1 OFF ON OFF 34 ROJ208394/1 R1D CA71535384 20131029 +57C
0 15 EPB1 OFF ON OFF 59 ROJ208394/1 R1D CA71535319 20131029 +57C
0 16 EPB1 OFF ON OFF 28 ROJ208394/1 R1D CA71535303 20131029 +60C
0 17 EPB1 OFF ON OFF 31 ROJ208394/1 R1D A065085201 20131203 +58C
0 18 EPB1 OFF ON OFF 43 ROJ208394/1 R1D A065085218 20131203 +59C
0 19 EPB1 OFF ON OFF 46 ROJ208394/1 R1D A065085224 20131203 +59C
0 20 EPB1 OFF ON OFF 65 ROJ208394/1 R1D A065085223 20131203 +57C
0 22 EPB1 OFF ON OFF 52 ROJ208394/1 R1D CA71535402 20131029 +59C
0 23 EVOET OFF ON OFF 55 ROJ208467/1 R1E A065082702 20131127 +76C
0 24 EPB1 OFF ON OFF 49 ROJ208394/1 R1D CA71543569 20131101 +60C
0 25 EPB1 OFF ON OFF 68 ROJ208394/1 R1D CA71543576 20131101 +62C Active
0 26 EPB1 OFF ON OFF 62 ROJ208394/1 R1D CA71543573 20131101 +62C
0 27 SCXB3 OFF ON OFF 71 ROJ208395/1 R6B A065078544 20131120
0 28 CMXB3 OFF ON OFF 72 ROJ208392/1 R7D A065083936 20131129
---------------------------------------------------------------------------------------------------------------
-EPB1: Alarm limit: 95 degrees Celsius. Alarm cease limit: 85 degrees Celsius
EVOET: Alarm limit: 110 degrees Celsius. Alarm cease limit: 65 degrees Celsius
================================================================
SMN ProductNr Rev Name Date SerialNr
================================================================
0 ROJ6091001/2 R2A BACKPLANE
0 ROJ 609 1001/2 R2A EGEM2 40G BP X912305373
----------------------------------------------------------------
===============================================================================================================
=
SMN APN PORT BOARD FAULT OPER MAINT PRODUCT NR REV SERIAL DATE TEMP
===============================================================================================================
=
---------------------------------------------------------------------------------------------------------------
-
.
===================================================================================
CONNECTED POS S LED NAME PRODUCT NR REV SERIAL DATE
===================================================================================
000100 LOWER 0 OFF FANUNIT BFB14013/1 R11B X052231145 20130916
002700 UPPER 0 OFF FANUNIT BFB14013/1 R11B X052233720 20130918
000100 1 OFF O/Econv. KDU137557/4 R4A A442737559 20131107
002700 1 OFF O/Econv. KDU137557/4 R4A A442737542 20131107
5. Checking Ranap and Rnsap connectivity.
Ranap have 2 elements
a. Iu-Cs connection – voice traffic and signaling towards core nodes.
b. Iu-Ps connection – packet/internet traffic and signaling
Rnsap carrying RNC to another RNC Iur traffic for call handover, inter RNC neighbour relation.
R021E> st ranap
141213-14:05:22 10.10.121.133 10.0n RNC_NODE_MODEL_U_1_2679 stopfile=/tmp/16330
===================================================================================
Proxy Adm State Op. State MO
===================================================================================
492 1 (ENABLED) TransportNetwork=1,SccpSp=1,SccpScrc=1,SccpApLocal=RanapLocal
7527 1 (ENABLED) RncFunction=1,CnOperator=1,IuLink=PS1,Ranap=GSSZA
7529 1 (ENABLED) RncFunction=1,CnOperator=1,IuLink=PS2,Ranap=GSRHA
7531 1 (ENABLED) RncFunction=1,CnOperator=1,IuLink=PS3,Ranap=GSMDA
7533 1 (ENABLED) RncFunction=1,CnOperator=1,IuLink=PS4,Ranap=GSTZA
7558 1 (ENABLED) RncFunction=1,CnOperator=1,IuLink=CS1,Ranap=MSTDB
7560 1 (ENABLED) RncFunction=1,CnOperator=1,IuLink=CS2,Ranap=MSRHC
7562 1 (ENABLED) RncFunction=1,CnOperator=1,IuLink=CS3,Ranap=MSBEB
7564 1 (ENABLED) RncFunction=1,CnOperator=1,IuLink=CS4,Ranap=MSKZB
===================================================================================
Total: 9 MOs
Or user may use “|” to include both ranap and rnsap listing as above.
M3UA is the IP transport circuit for an SCCP connection from RNC towards the core nodes.
By default in the MCI network, 4 M3ua is define per connection.
Use command “st m3ua”
2.2.5 Command to be used in the NodeB session
1. Alarm checking in NodeB, same as per description in RNC part.
alt - Alarm list with time
ala - Alarm list in detail information
alc - Alar list in comma separated value. Useful to import in excel
format
2. Checking NodeB data
Listing hardware unit
Listing Nbap|sector|carrier|localcell
Listing CV / Configuration Version
Listing frequencyband in NodeB
Checking hardware, serial number and temperature by “cabx”
VSWR is the power return loss of antenna system and most probably having connection
physical problem.
high value when read > 1.5 dBm
RSSI is the Radio Signal Strength Indicator and associate to interference
high value when read > -99.00 dBm/ getting lower than -100.00 dBm reading
2. Block hardware NodeB
Blocking a DUW by using a PROXY NO as below and command “bl <proxy>”
How to know the unit.

More Related Content

PPT
E nodeb useful commands for rf engineer
PDF
Ericsson LTE Commands.pdf
PPT
Lte most used command rev1
PDF
224698998 moshell-commands
PPT
370410176 moshell-commands
PDF
AMOS MOSHELL OVERVIEW
PDF
Irat handover basics
TXT
Ericsson commond list, BSS+NSS=OSS
E nodeb useful commands for rf engineer
Ericsson LTE Commands.pdf
Lte most used command rev1
224698998 moshell-commands
370410176 moshell-commands
AMOS MOSHELL OVERVIEW
Irat handover basics
Ericsson commond list, BSS+NSS=OSS

What's hot (20)

PDF
Ericsson important optimization parameters
DOC
Commands...
PPT
216506756-Moshell-Basic-Command-v1-0.ppt
PDF
Enm cli
PDF
BaseBand-6630-Moshell-Commands .pdf
PPTX
LTE KPI Optimization - A to Z Abiola.pptx
PDF
TXT
Ericsson commond list bss nss oss
PDF
Lte kpi accessability
PDF
LTE Review - Load Balancing and Interfreq HO
PDF
LTE KPI and PI Formula_NOKIA.pdf
PDF
The_ERICSSON_commands_listed_below_are_f (1) (1).pdf
PDF
2 g and 3g kpi improvement by parameter optimization (nsn, ericsson, huawei) ...
PPT
Ericsson optimization opti
PPTX
Master Baseband 6620 & 6630 Commissioning On Site
PDF
3g counter & timer
PPT
Ericsson LTE Throughput Troubleshooting Techniques.ppt
PPTX
LTE Optimization-KPIs.pptx
PPT
Ericsson 2 g ran optimization complete training
PDF
UMTS/WCDMA Call Flows for Handovers
Ericsson important optimization parameters
Commands...
216506756-Moshell-Basic-Command-v1-0.ppt
Enm cli
BaseBand-6630-Moshell-Commands .pdf
LTE KPI Optimization - A to Z Abiola.pptx
Ericsson commond list bss nss oss
Lte kpi accessability
LTE Review - Load Balancing and Interfreq HO
LTE KPI and PI Formula_NOKIA.pdf
The_ERICSSON_commands_listed_below_are_f (1) (1).pdf
2 g and 3g kpi improvement by parameter optimization (nsn, ericsson, huawei) ...
Ericsson optimization opti
Master Baseband 6620 & 6630 Commissioning On Site
3g counter & timer
Ericsson LTE Throughput Troubleshooting Techniques.ppt
LTE Optimization-KPIs.pptx
Ericsson 2 g ran optimization complete training
UMTS/WCDMA Call Flows for Handovers
Ad

Similar to Amos command (20)

PPTX
Commisioning.pptx
PDF
Useful Moshell commands .pdf
PDF
fdocuments.in_the-ericsson-commands.pdf
PPT
Radio relay network auto discovery
PDF
Docfoc.com ericsson commands
PPT
EnodeB_Moshell_important_commands VERSION 1
PPTX
RNEC N101 Lite- RAX711-L.pptx
PPTX
ZXUR 9000 UMTS Hardware list about technology
PDF
Attach flow &amp; srb
PPT
E_Node_B_Useful_Commands.ppt
PPT
11715660.ppt
PDF
MINI-LINK PT_Node GUI Descriptions.pdf
PPTX
Routing over ericsson mini link
PDF
Extract from TEMS Investigation 17.0 Help
PDF
NED_Parameters 2G/GSM/EDGE BSS radio network parameters
PPTX
Introduction to Nokia RNC
PDF
Alarms_grouping_Current_Alarms.pdf
PDF
PLNOG 18 - Piotr Jabłoński - Co i jak można zautomatyzować u operatora?
PPT
E node b_useful_commands_for_rf_engineer
Commisioning.pptx
Useful Moshell commands .pdf
fdocuments.in_the-ericsson-commands.pdf
Radio relay network auto discovery
Docfoc.com ericsson commands
EnodeB_Moshell_important_commands VERSION 1
RNEC N101 Lite- RAX711-L.pptx
ZXUR 9000 UMTS Hardware list about technology
Attach flow &amp; srb
E_Node_B_Useful_Commands.ppt
11715660.ppt
MINI-LINK PT_Node GUI Descriptions.pdf
Routing over ericsson mini link
Extract from TEMS Investigation 17.0 Help
NED_Parameters 2G/GSM/EDGE BSS radio network parameters
Introduction to Nokia RNC
Alarms_grouping_Current_Alarms.pdf
PLNOG 18 - Piotr Jabłoński - Co i jak można zautomatyzować u operatora?
E node b_useful_commands_for_rf_engineer
Ad

More from Hossein Abbasi (14)

PDF
Ds 8630 smart_router_74_c0025
PDF
Ds 8625 smart_router_74_c0130 (1)
PDF
Ds 8615 smart_router_74_c0001
PDF
Ds 8609 smart_router_74_c0022
PDF
Ds 8602 smart_router_74_c0007 (1)
PDF
8600 smart router-portfolio_overview
TXT
Ericsson commond list, bss+nss=oss
TXT
Alarm hw entities_mismatch
TXT
Pmx . propa for log BSC
TXT
Script tcu 4command
PDF
Gsm farsi
PDF
Astelllia network poster
PDF
The Examining of GSM Operators
PDF
Aug12 sridhar
Ds 8630 smart_router_74_c0025
Ds 8625 smart_router_74_c0130 (1)
Ds 8615 smart_router_74_c0001
Ds 8609 smart_router_74_c0022
Ds 8602 smart_router_74_c0007 (1)
8600 smart router-portfolio_overview
Ericsson commond list, bss+nss=oss
Alarm hw entities_mismatch
Pmx . propa for log BSC
Script tcu 4command
Gsm farsi
Astelllia network poster
The Examining of GSM Operators
Aug12 sridhar

Amos command

  • 1. AMOS - COMMANDLINE INTERFACE 1. GETTING STARTED 1.1 LAUNCHING AMOS FROM OSS FRONT PAGE GUI AMOS MOSHELL SESSION IS OPEN DEFAULT FROM USER HOME DIRECTORY IN OSS. 1.2 LAUNCHING AMOS FROM OSS ONE/ OSS NETWORK EXPLORER
  • 2. THE AMOS SESSION DIRECTLY OPENED INTO R021E NODE. 2. USING AMOS 2.1 THESE ARE THE IP ADDRESSES OF THE RNC . RNC IP ADDRESS PASSWORD R021E 10.10.121.133 rnc@1234 R031E 10.17.121.133 rnc@1234 R041E 10.11.121.133 rnc@1234 R051E 10.18.121.133 rnc@1234 R061E 10.8.121.133 rnc@1234 R071E 10.14.121.133 rnc@1234
  • 3. 2.2 AMOS SESSION USER MAY USE NODE DNS NAME OR IP ADDRESS TO CONNECT TO THE NODE. WHEN THE IP CONTACT IS OK, BOTH IS ACCESSIBLE. 2.2.1 PLEASE USER SMALL LETTER FOR command initiation throughout the AMOS SESSION. amos R021E or amos 10.10.121.133 2.2.2 IP Addresses are used when the OSS does not define the updated Node DNS with its IP Address. 2.2.3 After amos R021E, user must send command “lt all”. This will refresh and load all MO’s information into the session. User may notice that for the “amos 10.10.121.133” the effect “lt all”, will later on read the node userlabel to be R021E. 2.2.4 Command to be used in the RNC session
  • 4. 1. Alarm checking in RNC alt - Alarm list with time ala - Alarm list in detail information alc - Alar list in comma separated value. Useful to import in excel format
  • 5. 2. Checking NodeB in RNC lst <NodeB ID> Normally, Site ID is starting with 2 alphabets follow by 4 digits. To check all subordinate of a cell, use “lst”. To check the main element use, ‘st”
  • 6. To see all site listing in the related RNC, use “str” To have site listing in CSV format, use “str <any label>”, it will create the file csv format and need to be transferred from OSS your user folder into your laptop and can be open in excel file as sample below. R021E> str UI0401 Output saved to CSV file: UI0401 R021E> !ls UI0401* UI0401 R021E> !pwd /home/nakzaidi File sample after excel extraction:
  • 7. 2014-17-12 Update of command “str” The implementation of 2nd carrier has cause some confusion to the output command “str”. It register the fully operational site as only 1 site and the rest, in under the second category – totally or partially unavailable. This is due to the 1st carrier utrancells are fully operational and 2nd carrier utrancells are LOCKED. The recommendation given to the issue is to monitor closely the red marker CELLNAMES column. Detail information here: Columns: MOD: this the RNC module that the site is defined in. IUBLINK: this is the identity of the iublink that the site is using. CELLNAME: this is the name of the cells that are connected to that IubLink. the cell names correspond to the respective sectors. eg: 6306-1/2/3 means that: cell 63061 is connected to SECT1 cell 63062 is connected to SECT2 cell 63063 is connected to SECT3. CFRPHEM: the first digit is the state of the UtranCell. the three following digits are the state of the common channels (Fach/Rach/Pch).
  • 8. the fifth digit (if present) represents the state of the hsdpa channel (Hsdsch). the sixth digit (if present) represents the state of the enhanced uplink channel (Eul). the seventh digit (if present) represents the state of the Mbms channel (MbmsCch). ICDS: the first digit is the state of the IubLink the second digit is the state of NbapCommon the third digit is the state of NbapDedicated Up to P5, the final two digits are the states of NodeSynchTp 1 and 2. From P6, the final digit is the state of NodeSynch. TN: The type of transport network used by the IubLink. A=ATM, I=IP, AI=DualStack States: - L = Locked - S = ShuttingDown - 0 = Unlocked & Disabled - 1 = Unlocked & Enabled Please concentrate on the highlighted column only.
  • 9. 3. Blocking/Deblocking a NodeB To block an utrancell only. The same when doing with command “bl <utrancell id>” Also the same when “bl <proxy no>”
  • 10. To block a site, use “bl <site id>” or “lbl <site id>” 4. Checking NodeB downtime from the log in RNC
  • 11. -s startdate lga Alarm log only lgaj Alarm log with duration. M* Alarm initiated with Major severity and “*” alarm cease. 5. Checking RNC hardware “st plug” - listing of main EPB1 board carry NodeB, Ranap,Rnsap traffic “cabx” - hardware information on board name, serial number, Temperature
  • 12. In RNC, Slot=3 and Slot=25 is the main controlling board, one in Active and another one must be in StandbyReady mode. It shown in “cabx” command. Alarm temperature will trigger if more than 85 Celsius. R021E> cabx 141213-12:51:16 10.10.121.133 10.0n RNC_NODE_MODEL_U_1_2679 stopfile=/tmp/1411 Please enter Node Password: ...........put /var/opt/ericsson/amos/moshell_logfiles/nakzaidi/logs_moshell/tempfiles/20141213- 113430_1203/lhCmd1411 /d/usr/lhCmd1411 ... OK .........put /var/opt/ericsson/amos/moshell_logfiles/nakzaidi/logs_moshell/tempfiles/20141213- 113430_1203/lhCmd1411 /d/usr/lhCmd1411 ... OK =============================================================================================================== = SMN APN BOARD FAULT OPER MAINT FRO PRODUCTNUMBER REV SERIAL DATE TEMP COREMGR =============================================================================================================== = 0 1 SCXB3 OFF ON OFF 2 ROJ208395/1 R6B A065078545 20131120 0 2 CMXB3 OFF ON OFF 20 ROJ208392/1 R7D A065083927 20131129
  • 13. 0 3 EPB1 OFF ON OFF 1 ROJ208394/1 R1D CA71543572 20131101 +58C StandbyReady* 0 4 EPB1 OFF ON OFF 5 ROJ208394/1 R1D CA71543575 20131101 +59C 0 5 EPB1 OFF ON OFF 8 ROJ208394/1 R1D CA71543609 20131101 +57C 0 6 EPB1 OFF ON OFF 25 ROJ208394/1 R1D CA71543554 20131101 +62C 0 7 EPB1 OFF ON OFF 14 ROJ208394/1 R1D CA71543616 20131101 +60C 0 8 EPB1 OFF ON OFF 11 ROJ208394/1 R1D CA71543574 20131101 +61C 0 10 EPB1 OFF ON OFF 17 ROJ208394/1 R1D CA71543555 20131101 +56C 0 11 EVOET OFF ON OFF 21 ROJ208467/1 R1E A065082733 20131127 +71C 0 12 EPB1 OFF ON OFF 40 ROJ208394/1 R1D CA71543571 20131101 +59C 0 13 EPB1 OFF ON OFF 37 ROJ208394/1 R1D CA71535377 20131029 +62C 0 14 EPB1 OFF ON OFF 34 ROJ208394/1 R1D CA71535384 20131029 +57C 0 15 EPB1 OFF ON OFF 59 ROJ208394/1 R1D CA71535319 20131029 +57C 0 16 EPB1 OFF ON OFF 28 ROJ208394/1 R1D CA71535303 20131029 +60C 0 17 EPB1 OFF ON OFF 31 ROJ208394/1 R1D A065085201 20131203 +58C 0 18 EPB1 OFF ON OFF 43 ROJ208394/1 R1D A065085218 20131203 +59C 0 19 EPB1 OFF ON OFF 46 ROJ208394/1 R1D A065085224 20131203 +59C 0 20 EPB1 OFF ON OFF 65 ROJ208394/1 R1D A065085223 20131203 +57C 0 22 EPB1 OFF ON OFF 52 ROJ208394/1 R1D CA71535402 20131029 +59C 0 23 EVOET OFF ON OFF 55 ROJ208467/1 R1E A065082702 20131127 +76C 0 24 EPB1 OFF ON OFF 49 ROJ208394/1 R1D CA71543569 20131101 +60C 0 25 EPB1 OFF ON OFF 68 ROJ208394/1 R1D CA71543576 20131101 +62C Active 0 26 EPB1 OFF ON OFF 62 ROJ208394/1 R1D CA71543573 20131101 +62C 0 27 SCXB3 OFF ON OFF 71 ROJ208395/1 R6B A065078544 20131120 0 28 CMXB3 OFF ON OFF 72 ROJ208392/1 R7D A065083936 20131129 --------------------------------------------------------------------------------------------------------------- -EPB1: Alarm limit: 95 degrees Celsius. Alarm cease limit: 85 degrees Celsius EVOET: Alarm limit: 110 degrees Celsius. Alarm cease limit: 65 degrees Celsius ================================================================ SMN ProductNr Rev Name Date SerialNr ================================================================ 0 ROJ6091001/2 R2A BACKPLANE 0 ROJ 609 1001/2 R2A EGEM2 40G BP X912305373 ----------------------------------------------------------------
  • 14. =============================================================================================================== = SMN APN PORT BOARD FAULT OPER MAINT PRODUCT NR REV SERIAL DATE TEMP =============================================================================================================== = --------------------------------------------------------------------------------------------------------------- - . =================================================================================== CONNECTED POS S LED NAME PRODUCT NR REV SERIAL DATE =================================================================================== 000100 LOWER 0 OFF FANUNIT BFB14013/1 R11B X052231145 20130916 002700 UPPER 0 OFF FANUNIT BFB14013/1 R11B X052233720 20130918 000100 1 OFF O/Econv. KDU137557/4 R4A A442737559 20131107 002700 1 OFF O/Econv. KDU137557/4 R4A A442737542 20131107 5. Checking Ranap and Rnsap connectivity. Ranap have 2 elements a. Iu-Cs connection – voice traffic and signaling towards core nodes. b. Iu-Ps connection – packet/internet traffic and signaling Rnsap carrying RNC to another RNC Iur traffic for call handover, inter RNC neighbour relation. R021E> st ranap 141213-14:05:22 10.10.121.133 10.0n RNC_NODE_MODEL_U_1_2679 stopfile=/tmp/16330 =================================================================================== Proxy Adm State Op. State MO =================================================================================== 492 1 (ENABLED) TransportNetwork=1,SccpSp=1,SccpScrc=1,SccpApLocal=RanapLocal 7527 1 (ENABLED) RncFunction=1,CnOperator=1,IuLink=PS1,Ranap=GSSZA 7529 1 (ENABLED) RncFunction=1,CnOperator=1,IuLink=PS2,Ranap=GSRHA 7531 1 (ENABLED) RncFunction=1,CnOperator=1,IuLink=PS3,Ranap=GSMDA 7533 1 (ENABLED) RncFunction=1,CnOperator=1,IuLink=PS4,Ranap=GSTZA
  • 15. 7558 1 (ENABLED) RncFunction=1,CnOperator=1,IuLink=CS1,Ranap=MSTDB 7560 1 (ENABLED) RncFunction=1,CnOperator=1,IuLink=CS2,Ranap=MSRHC 7562 1 (ENABLED) RncFunction=1,CnOperator=1,IuLink=CS3,Ranap=MSBEB 7564 1 (ENABLED) RncFunction=1,CnOperator=1,IuLink=CS4,Ranap=MSKZB =================================================================================== Total: 9 MOs Or user may use “|” to include both ranap and rnsap listing as above. M3UA is the IP transport circuit for an SCCP connection from RNC towards the core nodes. By default in the MCI network, 4 M3ua is define per connection. Use command “st m3ua”
  • 16. 2.2.5 Command to be used in the NodeB session 1. Alarm checking in NodeB, same as per description in RNC part. alt - Alarm list with time ala - Alarm list in detail information alc - Alar list in comma separated value. Useful to import in excel format 2. Checking NodeB data Listing hardware unit
  • 18. Listing frequencyband in NodeB Checking hardware, serial number and temperature by “cabx”
  • 19. VSWR is the power return loss of antenna system and most probably having connection physical problem. high value when read > 1.5 dBm RSSI is the Radio Signal Strength Indicator and associate to interference high value when read > -99.00 dBm/ getting lower than -100.00 dBm reading 2. Block hardware NodeB Blocking a DUW by using a PROXY NO as below and command “bl <proxy>”
  • 20. How to know the unit.