SlideShare a Scribd company logo
Ericsson Mini-Link Overview
Presented by: Ahmed Mohamed Nabeeh
Supervised by: Ahmed Shawkat Badie
Agenda
• Introduction
• TN Units
• Connecting to the Mini-link
• Traffic Routing
• Link performance measurements
• Configuration file and software upgrade
• Loops
• Replacing LTU, SMU2 and MMU cards
• Replacing NPU card
Introduction
• Ericsson Mini link IDUs can be categorized into two main
categories :
1)Compaq Node (CN)
2) Traffic Node (TN)
Compaq Node (CN)
• We use CN 210 at Mobinil
Compaq Node (CN)
• Pros
1)low cost
2)small size
• Cons
1)small capacity up to 8 E1s only
2) Not modular ,in case of HW failure the whole IDU
should be replaced
3)support 1+0 Configuration only
• Best suitable for end point sites.
Traffic Node (TN)
• TN can be categorized based on their Access module
magazine (AMM) to 20P and 6P where p refer to the number
of Units that can be fitted inside the AMM.
• Unlike the CN the TN operation is based on Units(Modules)
where every unit do a certain function and all of them are
connected through the backplane of the AMM .
• TN = AMM + Modules
Traffic Node (TN)
• We use TN 6P-C and TN 20P-B at Mobinil
20P 6P
Traffic Node (TN-6P)
• Pros
1)Average cost
2)Reasonable Size 3)Modular
4)SW Cross connection availability
• Cons
1)Support up to 5 sites only
• Best suitable for Medium Nodal sites.
Traffic Node (TN-20P)
• Pros
1)High Capacity up to 19 sites
2)Modular
3)Cross connection availability
• Cons
1)High Cost 2)Large Size
• Best suitable for Nodal sites & BSCs.
TN Units
• Access Module Magazine(AMM)
• Network Processing unit (NPU)
• Power Filtering Units (PFU)
• Fan Unit (FAU)
• Line Termination unit (LTU)
• Magazine Modem Unit (MMU)
TN Units
• TN units can be categorized based on their Size to
Full Width Module
Half Width Module
Access Module Magazine
• Connect all the units together through its Backplane.
• Backplane has six buses
Backplane Buses
• TDM bus: time division multiplexing for traffic routing
• PCI bus: peripheral component interconnect high speed bus
for control and supervision
• SPI bus: serial peripheral interface low speed bus for
management data
• Power bus: DC power from PFU to consumers
• 4 BPI bus: 4 board pair interconnect for communication
between 4 PIUs
• 2 BPI bus: 2 board pair interconnect for communication
between 2 PIUs
• High speed Ptb bus: for connecting HSU and NPU slots to
application PIU
Network Processing Unit(NPU)
Network Processing Unit(NPU)
• Holds the TN configuration and licenses on Non volatile
Memory.
• Control the TN operation through the PCI bus
• O&M interface for local Maintenance
• E1 & T1 Interfaces up to 4E1s for H.W unit and 8E1s for F.W
unit.
• DCN and management interfaces.
• External Alarms interfaces
• Mandatory Unit.
Power Filtering Unit (PFU)
PFU3B used in 6P AMM PFU1 used in 20P AMM
Power Filtering Unit (PFU)
• Supply power to the AMM .
• Can operate over +24 v or -48 v.
• SC protection and DC ripples Smoothing.
• Can be used with another one for redundancy (Protection).
• Mandatory Unit.
• Usually installed in Slot 00 or 01 .
Fan Unit (FAU)
FAU1 Used in 20p AMM
FAU2 Used in 6p AMM
Air In
Air out
Fan Unit (FAU)
• Direct the air flow throughout the AMM
• FAU1 is not inserted in the 20 p AMM ,it is installed above the
AMM hence it has a power socket and alarm socket to be
connected to the AMM PFU .
• Consists of 3 blowers for redundancy against equipment
failure.
• power can be supplied from two different sources for
redundancy against power failure.
• Mandatory Unit.
Line Termination unit (LTU)
PDH LTU SDH LTU
LTU 155 e
LTU 155 e/0
Line Termination unit (LTU)
• Connect external traffic to the TN.
• Can be either FW or HW depending on the AMM i.e. FW is
usually used in the 20p AMM while the HW is usually used in
the 6p AMM.
• Optional Unit
• Usually installed in slot 13 or 17 in the 20p AMM ,Slot 6 in the
6p AMM.
Magazine Modem Unit (MMU)
• We Use MMU2D or MMU2H at Mobinil
MMU2D
MMU2H
Magazine Modem Unit (MMU)
• Modulate the signal from the Base band to IF Band and vice
versa.
• Supply DC power to the RAU (ODU)
• Determine the Link Modulation scheme and Bandwidth.
• Both MMU2H & 2D support modulation up to 128 QAM ,they
also support adaptive modulation(Lowering the modulation
scheme to became more robust against fading)
• Only MMU2H supports XPIC .
• Mandatory Unit.
Connecting to the Mini-Link
• We can connect to Ericsson MW IDU [6P & TNP] using either a USB
cable or an Ethernet cable.
• in case of CN-210 we can connect using Ethernet cable only .
• Each IDU has its own IP, so the IP used in the below example is just
for illustration purpose.
• You must assign the Laptop IP within the range of the network of
the IDU to be able to connect properly to it.
• Usually assign the laptop IP = the IP of the IDU + 1 or 2
Example on Configuring the laptop TCP/IP
If the IDU TCP/IP Configuration is as shown :
IP :10.159.106.121
Subnet : 255.255.255.248
Configure the NIC as shown
IP : 10.159.106.122
Subnet : 255.255.255.248
DGW: 10.159.106.121
Identifying the right port
• CN-210
O&M Ethernet Port
Identifying the right port
• TN-20P
• We connect through the NPU located in slot 11.
TR7/LAN Interface
O&M USB Interface
Identifying the right port
• TN-6P
• We connect through the NPU located in slot 7.
TR2/LAN Interface
O&M USB Interface
Starting the SW
• Open Ericsson Mini-Link SW and choose IP from show NE as .
• Username : control_user
• Password : ericsson
• NE : IP written on the Mini-Link.
Traffic Routing
• Hub sites have usually been built by connecting individual
microwave Radio Terminals with cables through Digital
Distribution Frames (DDF) and external cross connection to
equipment.
• MINI-LINK TN provides a traffic routing function that
facilitates the handling of traffic aggregation. This function
enables interconnection of all traffic connections going
through the NE. This means that an aggregation site can be
realized using one AMM housing several Radio Terminals with
all the cross-connections done in the backplane.
Traffic Routing
• Interface (LTU and NPU) E1s on Ericsson Mini-Link are
identified by a number then a letter.
• Letters are A,B,C & D.
• Numbers from 1 to 8 .
• If we combine them together we can have up to 32 E1.
1 2 3 4 5 6 …. 30 31 32
1A 1B 1C 1D 2A 2B ….. 8B 8C 8D
Traffic Routing
• In SW cross connection: all the plug in cards are defined
according to the Node /Slot/E1 port.
• Example the 3rd E1 on the NPU of TN-20P will be written as
1/11/1C another example of 6th E1 of the NPU at TN-6P will
be written as 1/7/2B.
Node
E1
Card Slot #
Traffic Routing
• Right click on the site name and choose
Configure -> Traffic Routing
• A window like the below shall appear
Choose the MMU
card in interface 1
then choose E1
1/11/6
Traffic Routing
• Example if a new site to be routed from the BSC and we need
to connect 1A on the LTU located in slot 12 to the 6th E1 of the
MMU located in slot 10.
Choose the LTU
card in interface 2
then choose E1
1/12/1A
Press the arrow
button to create
the cross
connection
Traffic Routing
• Naming the cross connection
Click on Traffic
routing overview
Traffic Routing
• Naming the cross connection
Left click on the
E1 name
Link Performance Measurements
• Every 15 minutes the Link records the values of the below
1)BB (Background block) : blocks of data RX by the link
2)BBE : # of blocks that contain errors and can not be corrected
3)BBER : # of BBE / interval(Day or 15 minutes)
4)ES( Error Seconds) : # of seconds of incorrect(corrupted) data
5)ESR(Error second rate) : # of ES / interval(Day or 15 minutes)
6)SES (Severe error seconds) : 10 seconds or more of incorrect data
7)SESR : # of SESR / interval(Day or 15 minutes)
8)Unavailable Seconds : more than 30 % of the data sent per this
second has error i.e. data discarded by the link
LPF OVER CN
• Right click on Radio and choose performance to check the LPF
for the near end over the current and previous 15 minutes
and current and last day.
LPF OVER CN
• Click on continuous to check the LPF for Near and Far ends
since the startup of the link
LPF OVER CN
• Click on RF to check the current RSL for the near end and over
the last 7 days and since startup.
LPF OVER CN
• Click on Adaptive modulation to check the modulation
scheme used by link over the current and previous 15 minutes
/day
• Note that In case of fading the modulation scheme will vary.
LPF OVER TN
Right click on
the RAUIF of
the desired
MMU and
choose
performance
to check on
the LPF and
adaptive
modulation
as previous
LPF OVER TN
Right click on
the RF of the
desired
MMU and
choose
Power to
check the
current RSL
for the near
end and over
the last 7
days and
since startup.
Uploading/Downloading config. file
• N.E configuration (PIU configuration, XCs, Basic IP
configuration, etc.. ) are stored on a file named configuration
file
• This file is stored at three memories
1. Non volatile memory on the NPU
2. RMM (Removable memory module)
3. Volatile memory on the backplane
• In case of inconsistency i.e. the configuration file existing on the NPU is
different from the one on the RMM, which occurs after a replacement
action for the RMM or NPU, the node will boot in initial setup mode when
you will be requested to choose the boot source
Uploading/Downloading config. file
• Start the FTP server
Uploading/Downloading config. file
• In the Navigation Tree, right click the NE and form tools menu,
click Load Configuration.
• On the Load Configuration page, under Configuration File,
select Upload to FTP server and configure the FTP server to be
local
• If the configuration file should be stored on the PC, select
Local server, specify User Name and Password.
• Specify File Name. The configuration will be stored in the
<drive:>tn_ftp_hometn_backup_configuration folder.
Uploading/Downloading config. file
Uploading/Downloading config. file
Uploading/Downloading config. file
Uploading/Downloading config. file
Uploading/Downloading config. file
Software upgrade
• Baseline SW: bundle of software files used to
upgrade node PIU and does not include RAU
software
• There are two types upgrade
1. Baseline upgrade where all PIU are
updated at once (New link installation)
2. Module upgrade where a PIU SW is
updated
Software upgrade
• In the Navigation Tree, right click the NE and form tools menu, click
Software upgrade
• Choose the type of upgrade Baseline or module
• At the FTP configuration, select Local server, specify User Name and
Password.
• The SW files should be stored at
C:tn_ftp_hometn_system_releaseml_tn_software in order to be
recognized by craft terminal FTP server
• Click apply then next
• In settings choose the FTP server configuration, activation and
confirmation .
• On the Start Upgrade page, verify the requested actions and click
Start Upgrade
Software upgrade
• Baseline upgrade
Software upgrade
• Modules upgrade
Software upgrade
• Settings
Software upgrade
• Start the upgrade
Software upgrade
• Baseline upgrade in progress
Software upgrade
• Module upgrade in progress
Software upgrade
• Activation in progress
Software upgrade
• Confirm New Software Configuration
Loops
• Loops can be used to verify that the transmission system is
working properly or they can be used to locate the faulty unit
or interface in case of failure.
Loops
• E1 Loops
1. Line loop: Loops an incoming line signal back to its
origin.
2.Local loop: Loops a line signal received from the
backplane back to its origin.
• 3.Connection loop: Loops an E1 interface connected to
the backplane back to its origin. The
loop is done in the backplane.
Loops
• E1 Loops
Loops
• E1 Loops
Navigate to the desired card then right click tools and
choose E1 loops
Loops
• Radio Loops
1. IF loop: In the MMU the traffic signal to be transmitted
is, after being modulated, mixed with the
frequency of a local oscillator, looped back
for demodulation (on the receiving side).
2.RF loop: In the RAU a fraction of the RF signal
transmitted is shifted in frequency and looped
back to the receiving side.
• 3.RX loop: group of E1s in the traffic connection is looped
back to its origin. The Rx Loop can be used to
verify the communication over the radio path.
Loops
• Radio Loops
Loops
• Radio Loops
Navigate to the desired radio link then right click tools
and choose radio loops
Replacing LTU, SMU2 and MMU card
• Undo the two screws (using T8 star screw driver) on the
latches.
• Disconnect all cables from the plug-in unit.
• Press the BR (Board Removal) button gently for a few seconds
and release it. This is a request to take the plug-in unit Out of
Service and all traffic related alarms will be disabled.
Replacing LTU, MMU and PFU
• Wait until the BR (yellow) LED is ON and then remove the plug-in
unit
• within 60 seconds. If the LED is not ON within 60 seconds, press and
• release the BR button again. Wait another 60 seconds and if the
LED is still not ON, remove the unit anyway.
• Insert the new plug-in unit within 15 minutes of removal. The plug-
in unit will automatically be taken into service.
• If the plug-in unit is not inserted within 15 minutes of removal, it
has to be re-configured
• Tighten the two screws on the latches.
• Connect the station radio cable.
• Depending on the software release installed on the card you may
need to perform an upgrade or not
Replacing NPU card
• The NPU which holds the NE configuration data, can be
replaced without disturbing all traffic not directly connected
to the unit. The procedure is performed while the NE is
running in NPU Installation mode.
• You need a backup configuration file on the FTP server on
your PC. The configuration file must have the following path:
C:tn_ftp_hometn_backup_configuration<hostname.cfg>.
Replacing NPU card
• Undo the two screws (using T8 star screw driver) on the
latches.
• Disconnect all cables from the plug-in unit.
• Press the BR (Board Removal) button gently for a few seconds
and release it. This is a request to take the plug-in unit Out of
Service and all traffic related alarms will be disabled.
Replacing NPU card
• Wait until the BR (yellow) LED is ON and then remove the
plug-in unit
• within 60 seconds. If the LED is not ON within 60 seconds,
press and
• release the BR button again. Wait another 60 seconds and if
the LED is still not ON, remove the unit anyway.
• Remove the RMM from the old card and insert it in the new
card
• Insert the new card and Press and release the BR button while
the Fault (red), Power (green) and BR (yellow) LEDs are ON
(NPU power up). The BR (yellow) LED will start flashing,
indicating that the NE is in NPU Installation mode.
Replacing NPU card
• You can either choose to boot the node from the RMM which
holds the old configuration or start a connection to the FTP
server (Laptop) and download the configuration file you
backed up earlier afterwards the Node will auto reset and
boot into normal mode
• You can remove the NPU and the node will be down since
there is a backup configuration stored on the backplane
memory
• Depending on the software release installed on the card you
may need to perform an upgrade or not
THANK YOU

More Related Content

PDF
Ericsson Mini-link 6600 Nodes
PPTX
Ericsson TN Cards in Details
PDF
Xpic implementation xpd alignment interference test
PPT
Basics Of Minilink Microwave Networks
PPTX
TRM MINI-LINK TN Presentation By Khalil Al-Alami
PDF
Ericsson RBS 6000
PDF
Minilink TN Ethernet Config.pdf
DOC
Mini link tn configuration
Ericsson Mini-link 6600 Nodes
Ericsson TN Cards in Details
Xpic implementation xpd alignment interference test
Basics Of Minilink Microwave Networks
TRM MINI-LINK TN Presentation By Khalil Al-Alami
Ericsson RBS 6000
Minilink TN Ethernet Config.pdf
Mini link tn configuration

What's hot (20)

PPT
Handling Common Faults and Alarms for Huawei RTN Microwaves
PDF
config_mini link
PPT
Mw training slide
PDF
Ericsson BTS commisioning
PDF
Step by step to install tn6 p
PDF
Microwave Huawei RTN Hardware Structure
PPTX
Dcn configuration via cli
PDF
5G Huawei BTS5900
PDF
Mini link tn-etsi_technical1
PPT
Huawei umts node b configuration principle
PPT
Bts installation & commisioning.ppt
PPT
02 opti x rtn 900 v100r002 system hardware-20100223-a
PPTX
Introduction to Nokia RNC
PDF
240243228 huawei-bts-3900-training
PPTX
Zxmw nr8250 v1.00 commissioning guide ¸±±¾
PPSX
Paging in LTE
PPTX
Huawei XPIC Hardware Connection
PPT
Ericsson Microwave Products Overview.ppt
PDF
519710952-6366-MW-HOP-Installation-Guidelines-Bhartij.pdf
Handling Common Faults and Alarms for Huawei RTN Microwaves
config_mini link
Mw training slide
Ericsson BTS commisioning
Step by step to install tn6 p
Microwave Huawei RTN Hardware Structure
Dcn configuration via cli
5G Huawei BTS5900
Mini link tn-etsi_technical1
Huawei umts node b configuration principle
Bts installation & commisioning.ppt
02 opti x rtn 900 v100r002 system hardware-20100223-a
Introduction to Nokia RNC
240243228 huawei-bts-3900-training
Zxmw nr8250 v1.00 commissioning guide ¸±±¾
Paging in LTE
Huawei XPIC Hardware Connection
Ericsson Microwave Products Overview.ppt
519710952-6366-MW-HOP-Installation-Guidelines-Bhartij.pdf
Ad

Viewers also liked (9)

PDF
Chap06 Telecommunications and Networks
PDF
Microwave_Transmission_Associate Certification
PDF
Microwave_Transmission_Professional_Certification
PPTX
Training on microwave communication
PPT
Microwave Transmission
PPTX
Microwave link communication system
PPT
Digital microwave communication principles
PPT
Point to point microwave
PPT
Microwave Antenna
Chap06 Telecommunications and Networks
Microwave_Transmission_Associate Certification
Microwave_Transmission_Professional_Certification
Training on microwave communication
Microwave Transmission
Microwave link communication system
Digital microwave communication principles
Point to point microwave
Microwave Antenna
Ad

Similar to Routing over ericsson mini link (20)

PPT
MINI-LINK TN R4 Training Document MINI-LINK TN R4 System Description
PPTX
STNAMS lec1.pptxx̌xxxxxxxxxxxxxxxxxxxxxx
PDF
Ls catalog thiet bi tu dong master p 5000-e_dienhathe.vn
PDF
Ls catalog thiet bi tu dong master p 5000-e
PPTX
Commisioning.pptx
PPT
Sdh total final
PPTX
Fttx arcitectures
PPTX
Cdot Max ng architecture working models
PDF
embedded system introduction to microcontrollers
PPTX
Presentation1
PDF
Procedure install cn510 step by step
PPTX
LTE_Basic_principle.pptx
PPSX
HCTE C&C08(TDM)
PPT
dokumen.tips_ericsson-lte-throughput-troubleshooting-techniques_SUPERRRRRRR.ppt
PPT
dokumen.tips_ericsson-lte-throughput-troubleshooting-techniquesppt.ppt
PPT
Ericsson LTE Throughput Troubleshooting Techniques.ppt
PPT
CDcghxdhmgjhkjgkjgjkggjkgffjffhfhfhjfhjfjhfjhfjhdggjjkgkjgkOT.ppt
PPTX
SON Server Web KPI Portal 4G DT Analysis Cases Module.pptx
PDF
Passive Optical Networks: The MAC protocols
PDF
MSIP report
MINI-LINK TN R4 Training Document MINI-LINK TN R4 System Description
STNAMS lec1.pptxx̌xxxxxxxxxxxxxxxxxxxxxx
Ls catalog thiet bi tu dong master p 5000-e_dienhathe.vn
Ls catalog thiet bi tu dong master p 5000-e
Commisioning.pptx
Sdh total final
Fttx arcitectures
Cdot Max ng architecture working models
embedded system introduction to microcontrollers
Presentation1
Procedure install cn510 step by step
LTE_Basic_principle.pptx
HCTE C&C08(TDM)
dokumen.tips_ericsson-lte-throughput-troubleshooting-techniques_SUPERRRRRRR.ppt
dokumen.tips_ericsson-lte-throughput-troubleshooting-techniquesppt.ppt
Ericsson LTE Throughput Troubleshooting Techniques.ppt
CDcghxdhmgjhkjgkjgjkggjkgffjffhfhfhjfhjfjhfjhfjhdggjjkgkjgkOT.ppt
SON Server Web KPI Portal 4G DT Analysis Cases Module.pptx
Passive Optical Networks: The MAC protocols
MSIP report

Recently uploaded (20)

PPTX
Detection-First SIEM: Rule Types, Dashboards, and Threat-Informed Strategy
PDF
How UI/UX Design Impacts User Retention in Mobile Apps.pdf
PDF
Machine learning based COVID-19 study performance prediction
PDF
Encapsulation theory and applications.pdf
PDF
TokAI - TikTok AI Agent : The First AI Application That Analyzes 10,000+ Vira...
PDF
Review of recent advances in non-invasive hemoglobin estimation
PDF
Chapter 3 Spatial Domain Image Processing.pdf
PDF
Diabetes mellitus diagnosis method based random forest with bat algorithm
PDF
NewMind AI Monthly Chronicles - July 2025
PDF
Unlocking AI with Model Context Protocol (MCP)
PDF
Building Integrated photovoltaic BIPV_UPV.pdf
PPTX
KOM of Painting work and Equipment Insulation REV00 update 25-dec.pptx
PPTX
Big Data Technologies - Introduction.pptx
PDF
Shreyas Phanse Resume: Experienced Backend Engineer | Java • Spring Boot • Ka...
PDF
Reach Out and Touch Someone: Haptics and Empathic Computing
PDF
Per capita expenditure prediction using model stacking based on satellite ima...
PDF
Approach and Philosophy of On baking technology
PDF
Blue Purple Modern Animated Computer Science Presentation.pdf.pdf
PDF
Bridging biosciences and deep learning for revolutionary discoveries: a compr...
PPTX
Effective Security Operations Center (SOC) A Modern, Strategic, and Threat-In...
Detection-First SIEM: Rule Types, Dashboards, and Threat-Informed Strategy
How UI/UX Design Impacts User Retention in Mobile Apps.pdf
Machine learning based COVID-19 study performance prediction
Encapsulation theory and applications.pdf
TokAI - TikTok AI Agent : The First AI Application That Analyzes 10,000+ Vira...
Review of recent advances in non-invasive hemoglobin estimation
Chapter 3 Spatial Domain Image Processing.pdf
Diabetes mellitus diagnosis method based random forest with bat algorithm
NewMind AI Monthly Chronicles - July 2025
Unlocking AI with Model Context Protocol (MCP)
Building Integrated photovoltaic BIPV_UPV.pdf
KOM of Painting work and Equipment Insulation REV00 update 25-dec.pptx
Big Data Technologies - Introduction.pptx
Shreyas Phanse Resume: Experienced Backend Engineer | Java • Spring Boot • Ka...
Reach Out and Touch Someone: Haptics and Empathic Computing
Per capita expenditure prediction using model stacking based on satellite ima...
Approach and Philosophy of On baking technology
Blue Purple Modern Animated Computer Science Presentation.pdf.pdf
Bridging biosciences and deep learning for revolutionary discoveries: a compr...
Effective Security Operations Center (SOC) A Modern, Strategic, and Threat-In...

Routing over ericsson mini link

  • 1. Ericsson Mini-Link Overview Presented by: Ahmed Mohamed Nabeeh Supervised by: Ahmed Shawkat Badie
  • 2. Agenda • Introduction • TN Units • Connecting to the Mini-link • Traffic Routing • Link performance measurements • Configuration file and software upgrade • Loops • Replacing LTU, SMU2 and MMU cards • Replacing NPU card
  • 3. Introduction • Ericsson Mini link IDUs can be categorized into two main categories : 1)Compaq Node (CN) 2) Traffic Node (TN)
  • 4. Compaq Node (CN) • We use CN 210 at Mobinil
  • 5. Compaq Node (CN) • Pros 1)low cost 2)small size • Cons 1)small capacity up to 8 E1s only 2) Not modular ,in case of HW failure the whole IDU should be replaced 3)support 1+0 Configuration only • Best suitable for end point sites.
  • 6. Traffic Node (TN) • TN can be categorized based on their Access module magazine (AMM) to 20P and 6P where p refer to the number of Units that can be fitted inside the AMM. • Unlike the CN the TN operation is based on Units(Modules) where every unit do a certain function and all of them are connected through the backplane of the AMM . • TN = AMM + Modules
  • 7. Traffic Node (TN) • We use TN 6P-C and TN 20P-B at Mobinil 20P 6P
  • 8. Traffic Node (TN-6P) • Pros 1)Average cost 2)Reasonable Size 3)Modular 4)SW Cross connection availability • Cons 1)Support up to 5 sites only • Best suitable for Medium Nodal sites.
  • 9. Traffic Node (TN-20P) • Pros 1)High Capacity up to 19 sites 2)Modular 3)Cross connection availability • Cons 1)High Cost 2)Large Size • Best suitable for Nodal sites & BSCs.
  • 10. TN Units • Access Module Magazine(AMM) • Network Processing unit (NPU) • Power Filtering Units (PFU) • Fan Unit (FAU) • Line Termination unit (LTU) • Magazine Modem Unit (MMU)
  • 11. TN Units • TN units can be categorized based on their Size to Full Width Module Half Width Module
  • 12. Access Module Magazine • Connect all the units together through its Backplane. • Backplane has six buses
  • 13. Backplane Buses • TDM bus: time division multiplexing for traffic routing • PCI bus: peripheral component interconnect high speed bus for control and supervision • SPI bus: serial peripheral interface low speed bus for management data • Power bus: DC power from PFU to consumers • 4 BPI bus: 4 board pair interconnect for communication between 4 PIUs • 2 BPI bus: 2 board pair interconnect for communication between 2 PIUs • High speed Ptb bus: for connecting HSU and NPU slots to application PIU
  • 15. Network Processing Unit(NPU) • Holds the TN configuration and licenses on Non volatile Memory. • Control the TN operation through the PCI bus • O&M interface for local Maintenance • E1 & T1 Interfaces up to 4E1s for H.W unit and 8E1s for F.W unit. • DCN and management interfaces. • External Alarms interfaces • Mandatory Unit.
  • 16. Power Filtering Unit (PFU) PFU3B used in 6P AMM PFU1 used in 20P AMM
  • 17. Power Filtering Unit (PFU) • Supply power to the AMM . • Can operate over +24 v or -48 v. • SC protection and DC ripples Smoothing. • Can be used with another one for redundancy (Protection). • Mandatory Unit. • Usually installed in Slot 00 or 01 .
  • 18. Fan Unit (FAU) FAU1 Used in 20p AMM FAU2 Used in 6p AMM Air In Air out
  • 19. Fan Unit (FAU) • Direct the air flow throughout the AMM • FAU1 is not inserted in the 20 p AMM ,it is installed above the AMM hence it has a power socket and alarm socket to be connected to the AMM PFU . • Consists of 3 blowers for redundancy against equipment failure. • power can be supplied from two different sources for redundancy against power failure. • Mandatory Unit.
  • 20. Line Termination unit (LTU) PDH LTU SDH LTU LTU 155 e LTU 155 e/0
  • 21. Line Termination unit (LTU) • Connect external traffic to the TN. • Can be either FW or HW depending on the AMM i.e. FW is usually used in the 20p AMM while the HW is usually used in the 6p AMM. • Optional Unit • Usually installed in slot 13 or 17 in the 20p AMM ,Slot 6 in the 6p AMM.
  • 22. Magazine Modem Unit (MMU) • We Use MMU2D or MMU2H at Mobinil MMU2D MMU2H
  • 23. Magazine Modem Unit (MMU) • Modulate the signal from the Base band to IF Band and vice versa. • Supply DC power to the RAU (ODU) • Determine the Link Modulation scheme and Bandwidth. • Both MMU2H & 2D support modulation up to 128 QAM ,they also support adaptive modulation(Lowering the modulation scheme to became more robust against fading) • Only MMU2H supports XPIC . • Mandatory Unit.
  • 24. Connecting to the Mini-Link • We can connect to Ericsson MW IDU [6P & TNP] using either a USB cable or an Ethernet cable. • in case of CN-210 we can connect using Ethernet cable only . • Each IDU has its own IP, so the IP used in the below example is just for illustration purpose. • You must assign the Laptop IP within the range of the network of the IDU to be able to connect properly to it. • Usually assign the laptop IP = the IP of the IDU + 1 or 2
  • 25. Example on Configuring the laptop TCP/IP If the IDU TCP/IP Configuration is as shown : IP :10.159.106.121 Subnet : 255.255.255.248 Configure the NIC as shown IP : 10.159.106.122 Subnet : 255.255.255.248 DGW: 10.159.106.121
  • 26. Identifying the right port • CN-210 O&M Ethernet Port
  • 27. Identifying the right port • TN-20P • We connect through the NPU located in slot 11. TR7/LAN Interface O&M USB Interface
  • 28. Identifying the right port • TN-6P • We connect through the NPU located in slot 7. TR2/LAN Interface O&M USB Interface
  • 29. Starting the SW • Open Ericsson Mini-Link SW and choose IP from show NE as . • Username : control_user • Password : ericsson • NE : IP written on the Mini-Link.
  • 30. Traffic Routing • Hub sites have usually been built by connecting individual microwave Radio Terminals with cables through Digital Distribution Frames (DDF) and external cross connection to equipment. • MINI-LINK TN provides a traffic routing function that facilitates the handling of traffic aggregation. This function enables interconnection of all traffic connections going through the NE. This means that an aggregation site can be realized using one AMM housing several Radio Terminals with all the cross-connections done in the backplane.
  • 31. Traffic Routing • Interface (LTU and NPU) E1s on Ericsson Mini-Link are identified by a number then a letter. • Letters are A,B,C & D. • Numbers from 1 to 8 . • If we combine them together we can have up to 32 E1. 1 2 3 4 5 6 …. 30 31 32 1A 1B 1C 1D 2A 2B ….. 8B 8C 8D
  • 32. Traffic Routing • In SW cross connection: all the plug in cards are defined according to the Node /Slot/E1 port. • Example the 3rd E1 on the NPU of TN-20P will be written as 1/11/1C another example of 6th E1 of the NPU at TN-6P will be written as 1/7/2B. Node E1 Card Slot #
  • 33. Traffic Routing • Right click on the site name and choose Configure -> Traffic Routing • A window like the below shall appear
  • 34. Choose the MMU card in interface 1 then choose E1 1/11/6 Traffic Routing • Example if a new site to be routed from the BSC and we need to connect 1A on the LTU located in slot 12 to the 6th E1 of the MMU located in slot 10. Choose the LTU card in interface 2 then choose E1 1/12/1A Press the arrow button to create the cross connection
  • 35. Traffic Routing • Naming the cross connection Click on Traffic routing overview
  • 36. Traffic Routing • Naming the cross connection Left click on the E1 name
  • 37. Link Performance Measurements • Every 15 minutes the Link records the values of the below 1)BB (Background block) : blocks of data RX by the link 2)BBE : # of blocks that contain errors and can not be corrected 3)BBER : # of BBE / interval(Day or 15 minutes) 4)ES( Error Seconds) : # of seconds of incorrect(corrupted) data 5)ESR(Error second rate) : # of ES / interval(Day or 15 minutes) 6)SES (Severe error seconds) : 10 seconds or more of incorrect data 7)SESR : # of SESR / interval(Day or 15 minutes) 8)Unavailable Seconds : more than 30 % of the data sent per this second has error i.e. data discarded by the link
  • 38. LPF OVER CN • Right click on Radio and choose performance to check the LPF for the near end over the current and previous 15 minutes and current and last day.
  • 39. LPF OVER CN • Click on continuous to check the LPF for Near and Far ends since the startup of the link
  • 40. LPF OVER CN • Click on RF to check the current RSL for the near end and over the last 7 days and since startup.
  • 41. LPF OVER CN • Click on Adaptive modulation to check the modulation scheme used by link over the current and previous 15 minutes /day • Note that In case of fading the modulation scheme will vary.
  • 42. LPF OVER TN Right click on the RAUIF of the desired MMU and choose performance to check on the LPF and adaptive modulation as previous
  • 43. LPF OVER TN Right click on the RF of the desired MMU and choose Power to check the current RSL for the near end and over the last 7 days and since startup.
  • 44. Uploading/Downloading config. file • N.E configuration (PIU configuration, XCs, Basic IP configuration, etc.. ) are stored on a file named configuration file • This file is stored at three memories 1. Non volatile memory on the NPU 2. RMM (Removable memory module) 3. Volatile memory on the backplane • In case of inconsistency i.e. the configuration file existing on the NPU is different from the one on the RMM, which occurs after a replacement action for the RMM or NPU, the node will boot in initial setup mode when you will be requested to choose the boot source
  • 46. Uploading/Downloading config. file • In the Navigation Tree, right click the NE and form tools menu, click Load Configuration. • On the Load Configuration page, under Configuration File, select Upload to FTP server and configure the FTP server to be local • If the configuration file should be stored on the PC, select Local server, specify User Name and Password. • Specify File Name. The configuration will be stored in the <drive:>tn_ftp_hometn_backup_configuration folder.
  • 52. Software upgrade • Baseline SW: bundle of software files used to upgrade node PIU and does not include RAU software • There are two types upgrade 1. Baseline upgrade where all PIU are updated at once (New link installation) 2. Module upgrade where a PIU SW is updated
  • 53. Software upgrade • In the Navigation Tree, right click the NE and form tools menu, click Software upgrade • Choose the type of upgrade Baseline or module • At the FTP configuration, select Local server, specify User Name and Password. • The SW files should be stored at C:tn_ftp_hometn_system_releaseml_tn_software in order to be recognized by craft terminal FTP server • Click apply then next • In settings choose the FTP server configuration, activation and confirmation . • On the Start Upgrade page, verify the requested actions and click Start Upgrade
  • 58. Software upgrade • Baseline upgrade in progress
  • 59. Software upgrade • Module upgrade in progress
  • 61. Software upgrade • Confirm New Software Configuration
  • 62. Loops • Loops can be used to verify that the transmission system is working properly or they can be used to locate the faulty unit or interface in case of failure.
  • 63. Loops • E1 Loops 1. Line loop: Loops an incoming line signal back to its origin. 2.Local loop: Loops a line signal received from the backplane back to its origin. • 3.Connection loop: Loops an E1 interface connected to the backplane back to its origin. The loop is done in the backplane.
  • 65. Loops • E1 Loops Navigate to the desired card then right click tools and choose E1 loops
  • 66. Loops • Radio Loops 1. IF loop: In the MMU the traffic signal to be transmitted is, after being modulated, mixed with the frequency of a local oscillator, looped back for demodulation (on the receiving side). 2.RF loop: In the RAU a fraction of the RF signal transmitted is shifted in frequency and looped back to the receiving side. • 3.RX loop: group of E1s in the traffic connection is looped back to its origin. The Rx Loop can be used to verify the communication over the radio path.
  • 68. Loops • Radio Loops Navigate to the desired radio link then right click tools and choose radio loops
  • 69. Replacing LTU, SMU2 and MMU card • Undo the two screws (using T8 star screw driver) on the latches. • Disconnect all cables from the plug-in unit. • Press the BR (Board Removal) button gently for a few seconds and release it. This is a request to take the plug-in unit Out of Service and all traffic related alarms will be disabled.
  • 70. Replacing LTU, MMU and PFU • Wait until the BR (yellow) LED is ON and then remove the plug-in unit • within 60 seconds. If the LED is not ON within 60 seconds, press and • release the BR button again. Wait another 60 seconds and if the LED is still not ON, remove the unit anyway. • Insert the new plug-in unit within 15 minutes of removal. The plug- in unit will automatically be taken into service. • If the plug-in unit is not inserted within 15 minutes of removal, it has to be re-configured • Tighten the two screws on the latches. • Connect the station radio cable. • Depending on the software release installed on the card you may need to perform an upgrade or not
  • 71. Replacing NPU card • The NPU which holds the NE configuration data, can be replaced without disturbing all traffic not directly connected to the unit. The procedure is performed while the NE is running in NPU Installation mode. • You need a backup configuration file on the FTP server on your PC. The configuration file must have the following path: C:tn_ftp_hometn_backup_configuration<hostname.cfg>.
  • 72. Replacing NPU card • Undo the two screws (using T8 star screw driver) on the latches. • Disconnect all cables from the plug-in unit. • Press the BR (Board Removal) button gently for a few seconds and release it. This is a request to take the plug-in unit Out of Service and all traffic related alarms will be disabled.
  • 73. Replacing NPU card • Wait until the BR (yellow) LED is ON and then remove the plug-in unit • within 60 seconds. If the LED is not ON within 60 seconds, press and • release the BR button again. Wait another 60 seconds and if the LED is still not ON, remove the unit anyway. • Remove the RMM from the old card and insert it in the new card • Insert the new card and Press and release the BR button while the Fault (red), Power (green) and BR (yellow) LEDs are ON (NPU power up). The BR (yellow) LED will start flashing, indicating that the NE is in NPU Installation mode.
  • 74. Replacing NPU card • You can either choose to boot the node from the RMM which holds the old configuration or start a connection to the FTP server (Laptop) and download the configuration file you backed up earlier afterwards the Node will auto reset and boot into normal mode • You can remove the NPU and the node will be down since there is a backup configuration stored on the backplane memory • Depending on the software release installed on the card you may need to perform an upgrade or not