1
BUILDING ELECTRICAL
WORKS
CONSTRUCTION MANPOWER DEVELOPMENT FOUNDATION
5/F Executive Center Building
369 Sen. Gil Puyat Ave.
Makati City
2
Introduction
• Codes and Standards
•Temporary C.O. (Construction)(Art. 3.5.1.6)
•Mounting Height
•Service Entrance
•3,100 mm – at the electric service entrance bldg., also at the lowest pt. of
the drip loop, & above areas or sidewalks accessible only to pedestrians,
measured from final grade or other accessible surface only for service drop
cables supported on and cabled together w/a grounded bare messenger
where V not exceed 300Vg.
•3,700 mm – over residential property and driveways, and those commercial
areas not subject to truck traffic where the voltage does not exceed 300V to
ground
•4,600 mm – for those areas listed in the 3700 classification where the
voltage exceeds 600V to ground.
•5,500 mm – over public streets, alleys, roads, parking areas subject to truck
traffic
3
3,100 mm – at the electric service entrance bldg., also at
the lowest pt. of the drip loop, & above areas or sidewalks
accessible only to pedestrians, measured fr. final grade or
other accessible surface only for service drop cables
supported on and cabled together w/a grounded bare
messenger where V not exceed 300Vg.
4
3,700 mm (12ft.) – over residential property and
driveways, and those commercial areas not subject to
truck traffic where the voltage does not exceed 300V to
ground.
5
4,600 mm – for those areas listed in the 3700 classification
where the voltage exceeds 600V to ground.
6
5,500 mm – over public streets, alleys, roads, parking areas
subject to truck traffic
7
Form from Meralco
8
• Codes and Standards
•Mounting Height
•Convenience Outlet
•Lighting Switches
•Minimum size of service drop conductor (Art. 2.30.2)
•Minimum size of service entrance conductor
(Art. 2.30.4.3)
•Grounding Electrode conductor (T2.50.3.17)
Electrical Plan
9
•COMMON ELECTRICAL SYMBOLS
•LIGHTING LAY-OUT
•POWER LAY-OUT
•SINGLE LINE DIAGRAM
•LOAD SCHEDULE
10
COMMON ELECTRICAL SYMBOLS
Panelboard
Duplex Convenience Outlet
Convenience Outlet , Counter Height
Water Heater Outlet , Grounding Type
Refrigerator Outlet , Grounding Type
ACU
Special Purpose Outlet , Aircon
LP-1 Circuit Homerun, indicating circuit number
Power Service Entrance
11
COMMON ELECTRICAL SYMBOLS
M Kilo Watt Hr Meter
Lighting Outlet
Sa Single Pole Device Light Switch
Sab Two Pole Device Light Switch
T
Telephone Outlet
Telephone Service Entrance
Circuit Breaker
12
13
14
SINGLE LINE DIAGRAM
15
LOAD SCHEDULE
16
ROUGH
IN
WORKS
WIRING
WORKS
ELECTRICAL
DEVICES
INSTALLATION
LIGHTING
FIXTURE
INSTALLATION
ELECTRICAL
EQUIPMENT
INSTALLATION
WORK
TESTING
And
COMISSIONING
17
ROUGH – IN - WORKS
COLUMN
BEAM
SLAB
DRY WALL
PARTITION
CEILING
CONCRETE WALL
18
ROUGH – IN - WORKS
a. Rigid Steel Conduit (RSC)
a. Cutting
b. Threading
c. Reaming
d. Bending
b. uPVC
a. Cutting
b. Bending
19
ROUGH – IN - WORKS
RSC PIPE BENDING
Conduit Bending Terms
Running End
20
ROUGH – IN - WORKS
RSC PIPE BENDING
1. 90° Bending
Since r=6D then;
4
C
S 
r
2
C 

4
)
D
6
(
2
4
C
S



D
3
S 

2. 60° Bending
Since r=6D then;
6
C
S 
r
2
C 

6
)
6
(
2
6
D
C
S



D
S 
2
21
ROUGH – IN - WORKS
RSC PIPE BENDING
Amount of Take-Up for 90° Bends
Size and Type of Conduit Take-Up
½ inch RSC 5 inches (12.7cm)
¾ inch RSC 7 inches(18 cm)
1 inch RSC 9.5 inches (24 cm)
22
ROUGH – IN - WORKS
23
ROUGH – IN - WORKS
24
ROUGH – IN - WORKS
25
ROUGH – IN - WORKS
26
ROUGH – IN - WORKS
27
WIRING WORKS
MAIN FEEDER LINE
SUB FEEDER LINE
BRANCH CIRCUITS
28
WIRING WORKS
a. Determining the number of conductors in a conduit run
b. Tagging of Wires
c. Wire fishing
d. Length of free conductors at outlets, junctions, and switch point
e. Splices
29
ELECTRICAL DEVICES
INSTALLATION
SWITCHES
RECEPTACLES
SPECIAL PURPOSE
OUTLET
SPECIAL PURPOSE
SWITCH
30
Receptacles
31
Special Purpose Outlets
32
Special Purpose Switch
33
SWITCH CONNECTION
a. Single Pole switch
b. Three-way switch
c. Four-way switch
Types of Switches
34
SWITCH CONNECTION
a. Single Pole
Return Wire ( RA )
L2 ( )
L1 ( + )
A
SA
35
b. 2-Single Pole/Duplex
SAB
A B
RA RB
L2 ( )
L1 ( )
SWITCH CONNECTION
36
c. Triplex/ 3 lamps controlled by individual switches in one location
RA RB
A B C
SABC
RC
L1 ( + )
L2 ( )
SWITCH CONNECTION
37
d. Three Way
Return Wire
( RW )
L2 ( )
L1 ( + )
Common
Traveler
Traveler
SWITCH CONNECTION
A
S3WA
S3WA
S3w S3w
Source
L.O.
A.
38
d. Three Way
SWITCH CONNECTION
S3w S3w
Source
L.O.
B.
S3w
S3w
Source
L.O.
C.
D.
S3w S3w
Source
L.O.
39
e. Four Way
Return Wire
( RW )
L2 ( )
L1 ( + )
Traveler
Traveler
C C
3-WAY
SWITCH
3-WAY
SWITCH
4-WAY
SWITCH
SWITCH CONNECTION
40
PROCEDURE:
1.0 Designate Positive Bar ( + ) from the line/panel and all the lines going
to lighting outlets , convenience outlets and pilot lamps.
R – Return Wire T – Traveler
2.0 Designate Negative Bar ( - ) from the line/panel and all the lines going
to switches and convenience outlets except for Three way and Four Way
switches.
For Three Way Switch – One line ( - ) for the nearest Three Way Sw. and
one line for RETURN wire going to farthest Three
way sw.
For Four Way Switch – All terminals are connected to traveler.
DETERMINING NUMBER OF CONDUCTORS IN CONDUIT RUN
41
A B C D
SAB
S3WC
S3WD
S3WC
S3WD
Ra
Ra
Rb
Rb
Rb
Rc
Rc Rc
Rd
Rd
Tc
Tc Tc
Tc
Td
Td Td
Td
Determine the number of conductors inside conduit run by
putting bars perpendicular to conduit.
3
3
2
2 2 2 2
5
6
5 6
42
A B C D
SAB
S3WC
S3WD
S3WC
S3WD
Ra
Ra
Rb
Rb
Rb
Rc
Rc Rc
Rd
Rd
TcL
TcL TcR
TcR
TDL
TDL TDR
TDR
S4WC
TcL
TDL
S4WD
TCR
TDR
Determine the number of conductors inside conduit run by
putting bars perpendicular to conduit.
3
3
2
2 2 2 2
5
6
5 6
8
43
PANEL BOARDS
METER CENTERS
MOTORS
ELECTRICAL EQUIPMENT
INSTALLATION
44
TESTING
and
COMMISIONING
CONTINUITY TESTING
LINE VOLTAGE TESTING
LINE CURRENT TESTING
INSULATION RESISTANCE
TESTING
EARTH
RESISTANCE TESTING
45

More Related Content

PPTX
PEC (1).pptx
PPTX
Electrical wiring system
DOC
17.cabling system
PDF
ELECTRICITYWIRING REGULATION for safety of
PPTX
Philippine-Electrical-Code-ALBgyyfftyyujhj
PDF
Basics of Electrical System Desiiign.pdf
PPTX
Residential wiring PPT.pptx
PPTX
electric and sanitary.pptx
PEC (1).pptx
Electrical wiring system
17.cabling system
ELECTRICITYWIRING REGULATION for safety of
Philippine-Electrical-Code-ALBgyyfftyyujhj
Basics of Electrical System Desiiign.pdf
Residential wiring PPT.pptx
electric and sanitary.pptx

Similar to Bldg-Electrical, proper knowledge's. .ppt (20)

PPTX
Project-Presentation-Group-04 on electrical layout.pptx
PDF
ASPiREBiM-Electrical Works Basic Training Module
PPT
electrical regulation ppt 0123321123333333
PDF
Guidelines for electrical wiring in residential buildings
PDF
5 Installing Premises Cabling System
PDF
01 guidelines for electrical work ace 9632136976
PPTX
Slide Presentation of Electrical System.
PPTX
P13 Electrical Installtions.pptx
DOCX
228279816 philippine-electrical-code-summary
PDF
combinepdf (24).pdf
PDF
ProcContSite
PPT
Floor plan-Electrical service design
PDF
ADU Plan 5 - 1200 sqft (1).pdf
PPTX
EEC MP-2.pptx222w3442erretrsdddreerereerwew33233wr
PPTX
Cable Installation Plan - SS-109 to 065.pptx
PDF
2 Basic Principal Of Utp Installation
PDF
2878-CC-001 COORDINATED SERVICES LAYOUT
PDF
Wiring complete (gnv64)
PPTX
Fundamentals of Electrical Services Design
PPTX
Wiring cost....gooooodd oneeeeeeeeee3e3e
Project-Presentation-Group-04 on electrical layout.pptx
ASPiREBiM-Electrical Works Basic Training Module
electrical regulation ppt 0123321123333333
Guidelines for electrical wiring in residential buildings
5 Installing Premises Cabling System
01 guidelines for electrical work ace 9632136976
Slide Presentation of Electrical System.
P13 Electrical Installtions.pptx
228279816 philippine-electrical-code-summary
combinepdf (24).pdf
ProcContSite
Floor plan-Electrical service design
ADU Plan 5 - 1200 sqft (1).pdf
EEC MP-2.pptx222w3442erretrsdddreerereerwew33233wr
Cable Installation Plan - SS-109 to 065.pptx
2 Basic Principal Of Utp Installation
2878-CC-001 COORDINATED SERVICES LAYOUT
Wiring complete (gnv64)
Fundamentals of Electrical Services Design
Wiring cost....gooooodd oneeeeeeeeee3e3e
Ad

Recently uploaded (20)

PPTX
AIR BAG SYStYEM mechanical enginweering.pptx
PPTX
Unit-1.pptxgeyeuueueu7r7r7r77r7r7r7uriruru
PPTX
ELETRONIC-PRODUCTS-ASSEMBLY-AND-SERVICING-NC-II-WEEK-1-Copy.pptx
DOCX
Copy-OT LIST 12.8.25.docxjdjfufufufufuuffuf
PPTX
Chapter no 8 output devices dpart 2.pptx
PDF
Printing Presentation to show beginners.
PPTX
Computer Hardware - Technology and Livelihood Education
PPTX
New professional education PROF-ED-7_103359.pptx
PDF
SAHIL PROdhdjejss yo yo pdf TOCOL PPT.pdf
PPTX
Subordinate_Clauses_BlueGradient_Optimized.pptx
PDF
ICT grade for 8. MATATAG curriculum .P2.pdf
PDF
2- Physical Layer (06).pdfgshshshbsbshshshhs
PPTX
AI_ML_Internship_WReport_Template_v2.pptx
PDF
Presented by ATHUL KRISHNA.S_20250813_191657_0000.pdf
PDF
CAB UNIT 1 with computer details details
PPTX
Clauses_Part1.hshshpjzjxnznxnxnndndndndndndndnndptx
PDF
GENERATOR AND IMPROVED COIL THEREFOR HAVINGELECTRODYNAMIC PROPERTIES
PPTX
vortex flow measurement in instrumentation
PDF
2_STM32&SecureElements2_STM32&SecureElements
PPTX
Group 4 [BSIT-1C] Computer Network (1).pptx
AIR BAG SYStYEM mechanical enginweering.pptx
Unit-1.pptxgeyeuueueu7r7r7r77r7r7r7uriruru
ELETRONIC-PRODUCTS-ASSEMBLY-AND-SERVICING-NC-II-WEEK-1-Copy.pptx
Copy-OT LIST 12.8.25.docxjdjfufufufufuuffuf
Chapter no 8 output devices dpart 2.pptx
Printing Presentation to show beginners.
Computer Hardware - Technology and Livelihood Education
New professional education PROF-ED-7_103359.pptx
SAHIL PROdhdjejss yo yo pdf TOCOL PPT.pdf
Subordinate_Clauses_BlueGradient_Optimized.pptx
ICT grade for 8. MATATAG curriculum .P2.pdf
2- Physical Layer (06).pdfgshshshbsbshshshhs
AI_ML_Internship_WReport_Template_v2.pptx
Presented by ATHUL KRISHNA.S_20250813_191657_0000.pdf
CAB UNIT 1 with computer details details
Clauses_Part1.hshshpjzjxnznxnxnndndndndndndndnndptx
GENERATOR AND IMPROVED COIL THEREFOR HAVINGELECTRODYNAMIC PROPERTIES
vortex flow measurement in instrumentation
2_STM32&SecureElements2_STM32&SecureElements
Group 4 [BSIT-1C] Computer Network (1).pptx
Ad

Bldg-Electrical, proper knowledge's. .ppt

  • 1. 1 BUILDING ELECTRICAL WORKS CONSTRUCTION MANPOWER DEVELOPMENT FOUNDATION 5/F Executive Center Building 369 Sen. Gil Puyat Ave. Makati City
  • 2. 2 Introduction • Codes and Standards •Temporary C.O. (Construction)(Art. 3.5.1.6) •Mounting Height •Service Entrance •3,100 mm – at the electric service entrance bldg., also at the lowest pt. of the drip loop, & above areas or sidewalks accessible only to pedestrians, measured from final grade or other accessible surface only for service drop cables supported on and cabled together w/a grounded bare messenger where V not exceed 300Vg. •3,700 mm – over residential property and driveways, and those commercial areas not subject to truck traffic where the voltage does not exceed 300V to ground •4,600 mm – for those areas listed in the 3700 classification where the voltage exceeds 600V to ground. •5,500 mm – over public streets, alleys, roads, parking areas subject to truck traffic
  • 3. 3 3,100 mm – at the electric service entrance bldg., also at the lowest pt. of the drip loop, & above areas or sidewalks accessible only to pedestrians, measured fr. final grade or other accessible surface only for service drop cables supported on and cabled together w/a grounded bare messenger where V not exceed 300Vg.
  • 4. 4 3,700 mm (12ft.) – over residential property and driveways, and those commercial areas not subject to truck traffic where the voltage does not exceed 300V to ground.
  • 5. 5 4,600 mm – for those areas listed in the 3700 classification where the voltage exceeds 600V to ground.
  • 6. 6 5,500 mm – over public streets, alleys, roads, parking areas subject to truck traffic
  • 8. 8 • Codes and Standards •Mounting Height •Convenience Outlet •Lighting Switches •Minimum size of service drop conductor (Art. 2.30.2) •Minimum size of service entrance conductor (Art. 2.30.4.3) •Grounding Electrode conductor (T2.50.3.17)
  • 9. Electrical Plan 9 •COMMON ELECTRICAL SYMBOLS •LIGHTING LAY-OUT •POWER LAY-OUT •SINGLE LINE DIAGRAM •LOAD SCHEDULE
  • 10. 10 COMMON ELECTRICAL SYMBOLS Panelboard Duplex Convenience Outlet Convenience Outlet , Counter Height Water Heater Outlet , Grounding Type Refrigerator Outlet , Grounding Type ACU Special Purpose Outlet , Aircon LP-1 Circuit Homerun, indicating circuit number Power Service Entrance
  • 11. 11 COMMON ELECTRICAL SYMBOLS M Kilo Watt Hr Meter Lighting Outlet Sa Single Pole Device Light Switch Sab Two Pole Device Light Switch T Telephone Outlet Telephone Service Entrance Circuit Breaker
  • 12. 12
  • 13. 13
  • 17. 17 ROUGH – IN - WORKS COLUMN BEAM SLAB DRY WALL PARTITION CEILING CONCRETE WALL
  • 18. 18 ROUGH – IN - WORKS a. Rigid Steel Conduit (RSC) a. Cutting b. Threading c. Reaming d. Bending b. uPVC a. Cutting b. Bending
  • 19. 19 ROUGH – IN - WORKS RSC PIPE BENDING Conduit Bending Terms Running End
  • 20. 20 ROUGH – IN - WORKS RSC PIPE BENDING 1. 90° Bending Since r=6D then; 4 C S  r 2 C   4 ) D 6 ( 2 4 C S    D 3 S   2. 60° Bending Since r=6D then; 6 C S  r 2 C   6 ) 6 ( 2 6 D C S    D S  2
  • 21. 21 ROUGH – IN - WORKS RSC PIPE BENDING Amount of Take-Up for 90° Bends Size and Type of Conduit Take-Up ½ inch RSC 5 inches (12.7cm) ¾ inch RSC 7 inches(18 cm) 1 inch RSC 9.5 inches (24 cm)
  • 22. 22 ROUGH – IN - WORKS
  • 23. 23 ROUGH – IN - WORKS
  • 24. 24 ROUGH – IN - WORKS
  • 25. 25 ROUGH – IN - WORKS
  • 26. 26 ROUGH – IN - WORKS
  • 27. 27 WIRING WORKS MAIN FEEDER LINE SUB FEEDER LINE BRANCH CIRCUITS
  • 28. 28 WIRING WORKS a. Determining the number of conductors in a conduit run b. Tagging of Wires c. Wire fishing d. Length of free conductors at outlets, junctions, and switch point e. Splices
  • 33. 33 SWITCH CONNECTION a. Single Pole switch b. Three-way switch c. Four-way switch Types of Switches
  • 34. 34 SWITCH CONNECTION a. Single Pole Return Wire ( RA ) L2 ( ) L1 ( + ) A SA
  • 35. 35 b. 2-Single Pole/Duplex SAB A B RA RB L2 ( ) L1 ( ) SWITCH CONNECTION
  • 36. 36 c. Triplex/ 3 lamps controlled by individual switches in one location RA RB A B C SABC RC L1 ( + ) L2 ( ) SWITCH CONNECTION
  • 37. 37 d. Three Way Return Wire ( RW ) L2 ( ) L1 ( + ) Common Traveler Traveler SWITCH CONNECTION A S3WA S3WA S3w S3w Source L.O. A.
  • 38. 38 d. Three Way SWITCH CONNECTION S3w S3w Source L.O. B. S3w S3w Source L.O. C. D. S3w S3w Source L.O.
  • 39. 39 e. Four Way Return Wire ( RW ) L2 ( ) L1 ( + ) Traveler Traveler C C 3-WAY SWITCH 3-WAY SWITCH 4-WAY SWITCH SWITCH CONNECTION
  • 40. 40 PROCEDURE: 1.0 Designate Positive Bar ( + ) from the line/panel and all the lines going to lighting outlets , convenience outlets and pilot lamps. R – Return Wire T – Traveler 2.0 Designate Negative Bar ( - ) from the line/panel and all the lines going to switches and convenience outlets except for Three way and Four Way switches. For Three Way Switch – One line ( - ) for the nearest Three Way Sw. and one line for RETURN wire going to farthest Three way sw. For Four Way Switch – All terminals are connected to traveler. DETERMINING NUMBER OF CONDUCTORS IN CONDUIT RUN
  • 41. 41 A B C D SAB S3WC S3WD S3WC S3WD Ra Ra Rb Rb Rb Rc Rc Rc Rd Rd Tc Tc Tc Tc Td Td Td Td Determine the number of conductors inside conduit run by putting bars perpendicular to conduit. 3 3 2 2 2 2 2 5 6 5 6
  • 42. 42 A B C D SAB S3WC S3WD S3WC S3WD Ra Ra Rb Rb Rb Rc Rc Rc Rd Rd TcL TcL TcR TcR TDL TDL TDR TDR S4WC TcL TDL S4WD TCR TDR Determine the number of conductors inside conduit run by putting bars perpendicular to conduit. 3 3 2 2 2 2 2 5 6 5 6 8
  • 44. 44 TESTING and COMMISIONING CONTINUITY TESTING LINE VOLTAGE TESTING LINE CURRENT TESTING INSULATION RESISTANCE TESTING EARTH RESISTANCE TESTING
  • 45. 45

Editor's Notes

  • #28: 150 mm of free conductor at junctions, outlets to make connection rapidly and efficiently. Splices should be as strong mechanically and as good a conductor as a continuous piece of wire. After the wire is spliced insulation must be equivalent to the original insulation.
  • #29: - Check the standard height, sw=1.2m, c.o.-0.3m minimum, counter top receptacle outlet shall be located above but not more than 0.45m above.