SlideShare a Scribd company logo
Medical Devices
Department of Engineering
February 11th
2015
Medical Devices
• What is a medical device
• Approvals required for studies involving medical
devices
• Who and how are they regulated
What is a medical device
• “Medical Device” covers all products, except
medicines, used in healthcare for the diagnosis,
prevention, monitoring or treatment of illness or
disability
Examples of medical
devices
• Implants
• Dressings
• Patient Monitoring equipment
• X ray systems
• Wheelchairs
• Hearing Aids
• Devices for blood glucose measurements
Examples of products that can be both
a medical device and non medical
device
• Personal protective equipment
• Who are you protecting?
• what is the principal stated purpose of the product by
the manufacturer?
• Rubber/latex gloves
• Marigolds = general purpose so not medical device
• surgical gloves = medical device
Stand alone software
• Software which is not incorporated in another
medical device but has a medical purpose
• Directly controls apparatus (radiotherapy)
• Provides immediate decision triggering
information (blood glucose meters)
• Provides support for healthcare professional (ECG
interpretation)
Decision tree for
standalone software
• Is it a computer programme?
• Does the programme perform an action on data?
• Is it for the benefit of an individual patient - will it
evaluate patient data to support or influence the
medical care provided to that patient?
• Words associated with a medical device
• amplify, analysis, interpret, alarms,
calculates, controls, converts, detects,
diagnose, measures, monitors
• Software that applies some sort of automated
reasoning - calculation, dose calculation,
algorithm, clinicians guide
APPs as medical devices
• Software that provides personalised guidance
• makes use of information entered by the
patients, provided by point of care devices or
obtained via health records, if it affects the
treatment of the patient
• If the software performs a calculation or
interprets data and the healthcare provider
does not review the raw data = medical device
Intention to “place on
market”
Research with the intention to “commercialise” the
device or
“place on the market” – make available in return for
payment or free of charge, with a view to
distribution, use or both
Requires MHRA approval
Manufacturer
Person responsible for the design, manufacture,
packaging and labelling of a device before it is
placed on the market
In house manufacture
• No intention to “put on the market” or place into
service under the manufacturer’s name
• There is no transfer of ownership of the product or
intention to give to another NHS Trust
• Not covered by medical device regulations but may
be covered by general research requirements if
used in a hospital
• Any data gathered cannot be used in a future
MHRA submission
Working with
Addenbrooke’s
If the Chief Investigator is an Addenbrooke’s
employee or a researcher based at the Clinical School
then this MAY be considered “in house” manufacture
R&D approval
Clinical Engineering approval
Electronic safety standards must be met
Evidence of liability cover
Research in a clinical
setting
Any study recruiting participants from the NHS,
using patient data or patient tissue requires NRES
ethics approval and R&D approval
Any study using NHS facilities in a study requires
R&D approval
Any study using NHS staff as participants in a study
requires R&D approval and University ethics
approval
Research with patients
• Sponsorship
• Confirmation of Funding
• Appropriate peer review
• Favourable ethical opinion letter
• Confirmation of insurance for your study
• Confirmation of honorary research contracts
• Appropriate agreements with third parties
Research Ethics
Proof of concept studies recruiting a small number of
healthy volunteers – internal ethics approval - but
considered on a case by case basis.
Studies recruiting a large group of healthy volunteers -
no longer a proof of concept study – MHRA assumption
that there is an intention to commercialise or “put on
market” – NRES ethics approval and MHRA approval
Clinical Investigation studies of medical device – NRES
ethics approval and may require MHRA approval
Insurance
Whatever the setting, if you are using a medical
device in any type of research, it is important to
ensure that appropriate insurance is in place
Insurance contact: Victoria Hollamby
Victoria.Hollamby@admin.cam.ac.uk
Medical devices and
regulation
• Devices are categorised into classes according to
the degree of risk inherent in the device
• Class I - low risk – apps, standalone software
• Class 11a and 11b – medium risk
• Class III high risk
• The conformity assessment and the CE mark
depend on the Class of the product
Classification
Depends upon a series of factors including:
How long the device is intended to be in
continuous use
Whether or not the device is invasive
Whether the device is implantable or active
Whether or not the device contains a substance
Non invasive device
Class I - In contact with injured skin – provide
mechanical barrier, eg plasters, wound gauze
Class IIa - Intended to manage micro-environment
of wound – control moisture at wound, eg hydrogel
dressings. Not for extensive wounds
Class IIb - Intended for wounds which breach
dermis and heal only by secondary intent – severe
burns eg temporary skin substitute
Class I
If you are satisfied that your medical device
complies with the requirements in the MDD, you
must write a statement to declare this –
“Declaration of Conformity”
As 11th
February 2015 new online application
system for Class I devices, (Device Online
Registration System, DORS) .
Class IIa and IIb
Safety and performance needs to be adequately
demonstrated – may need clinical investigation if
insufficient existing clinical data
Devices requiring clinical
investigation
Device is implantable or Class III medical device
Introducing new concept of device into medical
practice
Existing device modified so a novel feature may
have important phsyiological effects or it affects
clinical performance and safety of the device
Devices requiring clinical
investigation
Devices incorporating materials previously
untested in humans
Device, either CE marked or non CE marked, being
proposed for a new purpose or function
In vitro and/or animal testing of device cannot
mimic the clinical situation
New manufacturer, especially of a high risk device
Medical Device Directives
90/385/EEC – Active Implantable Device Directive
(AIMDD) – covers all powered implants or partial
implants that are left in the human body – pacemaker
93/42/EEC – Medical Device Directive (MDD) – covers
most other medical devices
98/79/EC – In-vitro Diagnostics Device (IVD) – covers
any device which is a reagent, instrument, appparatus,
for use in-vitor for examination of speciments from the
human body - hepatitis B testing kits
Organisations
Competent Authority – MHRA
Notified Body – CE Marking
Ethics – Health Research Authority NRES
NHS - R&D
MHRA
Ensures compliance with regulations
Evaluates adverse incident reports
Pre-clinical assessment of devices intended for
clinical trial
Designates the independent certification
organisation (notified bodies)
Notified Bodies
Check manufacturers of medium and high risk
devices have followed the requirement
Issue CE marks for these devices
Useful contacts
Research Governance Officer – Carolyn Read
cad50@medschl.cam.ac.uk 01223 769291
Research Governance Manager Addenbrooke’s
Hospital – Louise Stockley
louise.stockley@addenbrookes.nhs.uk
Useful websites
https://www.gov.uk/government/collections/regulatory-guidance-for-medical-
devices
http://ec.europa.eu/health/medical-devices/files/meddev/2_4_1_rev_9_classifi
cation_en.pdf
http://www.hra.nhs.uk/
http://www.hra.nhs.uk/resources/before-you-apply/types-of-ethical-review/et
hical-review-of-investigations-of-medical-devices
/

More Related Content

PPT
medical devices for the safety standards and codes
PPTX
Medical Device: A life changing innovation
PPTX
Presentation: Therapeutic Goods Administration: An introduction to the work o...
PPT
MHRA - 18th March 2014
PPTX
Indian MDR 2017 - 10 Feb 2025 Brief review
PPTX
MEDICAL DEVICES REGULATION by US FDA.pptx
PPTX
Regulatory Aspects of MEDICAL DEVICES.pptx
PPTX
The regulation of medical devices in Australia
medical devices for the safety standards and codes
Medical Device: A life changing innovation
Presentation: Therapeutic Goods Administration: An introduction to the work o...
MHRA - 18th March 2014
Indian MDR 2017 - 10 Feb 2025 Brief review
MEDICAL DEVICES REGULATION by US FDA.pptx
Regulatory Aspects of MEDICAL DEVICES.pptx
The regulation of medical devices in Australia

Similar to description of Medical devices department of engineering (20)

PDF
Update on software as a medical device (SaMD)
PPTX
Medical devices and IVD'S
PPTX
Medical device design guidlines
PPT
EU Medical Device Directive Newcastle May
PPTX
Medical devices
PPTX
Medical devices
PPTX
EU Medical Device Regulatory Framework_Dec, 2022
PDF
TGA webinar presentation: Regulation of software, including software as a med...
PDF
Update on software as a medical device (SaMD)
PPT
CFTCC Workshop: IDE Exemption, Preparation and Maintenance
PPTX
Embedded: Specific of Medical Projects
PPTX
THE REGULATION OF MEDICAL AI: POLICY APPROACHES, DATA, AND INNOVATION INCENTI...
PDF
Webinar presentation: The Role of Digital Health
PDF
Medical Product Development cycle
PPTX
current Clinical issues in medical devices.pptx
PPTX
The challenges of regulating direct to consumer digital medical devices
PPTX
Presentation: The challenges of regulating direct to consumer digital medical...
PDF
FDA SLIDES FOR YOUR REFERENCE ONLY YA.pdf
PDF
Chapter 21 Medical devices.pdf
PDF
MD.definition.lifecycle.supplementary.materials.pdf
Update on software as a medical device (SaMD)
Medical devices and IVD'S
Medical device design guidlines
EU Medical Device Directive Newcastle May
Medical devices
Medical devices
EU Medical Device Regulatory Framework_Dec, 2022
TGA webinar presentation: Regulation of software, including software as a med...
Update on software as a medical device (SaMD)
CFTCC Workshop: IDE Exemption, Preparation and Maintenance
Embedded: Specific of Medical Projects
THE REGULATION OF MEDICAL AI: POLICY APPROACHES, DATA, AND INNOVATION INCENTI...
Webinar presentation: The Role of Digital Health
Medical Product Development cycle
current Clinical issues in medical devices.pptx
The challenges of regulating direct to consumer digital medical devices
Presentation: The challenges of regulating direct to consumer digital medical...
FDA SLIDES FOR YOUR REFERENCE ONLY YA.pdf
Chapter 21 Medical devices.pdf
MD.definition.lifecycle.supplementary.materials.pdf
Ad

Recently uploaded (20)

PDF
Priorities Critical Care Nursing 7th Edition by Urden Stacy Lough Test Bank.pdf
PPTX
Immunity....(shweta).................pptx
PPTX
HEMODYNAMICS - I DERANGEMENTS OF BODY FLUIDS.pptx
PDF
Dr. Jasvant Modi - Passionate About Philanthropy
PDF
DAY-6. Summer class. Ppt. Cultural Nursing
PDF
Dermatology diseases Index August 2025.pdf
PPTX
General Pharmacology by Nandini Ratne, Nagpur College of Pharmacy, Hingna Roa...
PDF
MECE & SCQA FRAMEWORKS, - Adding Innovation & Influencing Hospital & Super-Sp...
PPT
Recent advances in Diagnosis of Autoimmune Disorders
PPTX
1. Drug Distribution System.pptt b pharmacy
PDF
2E-Learning-Together...PICS-PCISF con.pdf
PDF
CHAPTER 9 MEETING SAFETY NEEDS FOR OLDER ADULTS.pdf
PDF
Megan Miller Colona Illinois - Passionate About CrossFit
PPT
KULIAH UG WANITA Prof Endang 121110 (1).ppt
PPTX
Trichuris trichiura infection
PPTX
PE and Health 7 Quarter 3 Lesson 1 Day 3,4 and 5.pptx
PPTX
Galactosemia pathophysiology, clinical features, investigation and treatment ...
PPTX
BLS, BCLS Module-A life saving procedure
PPTX
CBT FOR OCD TREATMENT WITHOUT MEDICATION
PDF
Structure Composition and Mechanical Properties of Australian O.pdf
Priorities Critical Care Nursing 7th Edition by Urden Stacy Lough Test Bank.pdf
Immunity....(shweta).................pptx
HEMODYNAMICS - I DERANGEMENTS OF BODY FLUIDS.pptx
Dr. Jasvant Modi - Passionate About Philanthropy
DAY-6. Summer class. Ppt. Cultural Nursing
Dermatology diseases Index August 2025.pdf
General Pharmacology by Nandini Ratne, Nagpur College of Pharmacy, Hingna Roa...
MECE & SCQA FRAMEWORKS, - Adding Innovation & Influencing Hospital & Super-Sp...
Recent advances in Diagnosis of Autoimmune Disorders
1. Drug Distribution System.pptt b pharmacy
2E-Learning-Together...PICS-PCISF con.pdf
CHAPTER 9 MEETING SAFETY NEEDS FOR OLDER ADULTS.pdf
Megan Miller Colona Illinois - Passionate About CrossFit
KULIAH UG WANITA Prof Endang 121110 (1).ppt
Trichuris trichiura infection
PE and Health 7 Quarter 3 Lesson 1 Day 3,4 and 5.pptx
Galactosemia pathophysiology, clinical features, investigation and treatment ...
BLS, BCLS Module-A life saving procedure
CBT FOR OCD TREATMENT WITHOUT MEDICATION
Structure Composition and Mechanical Properties of Australian O.pdf
Ad

description of Medical devices department of engineering

  • 1. Medical Devices Department of Engineering February 11th 2015
  • 2. Medical Devices • What is a medical device • Approvals required for studies involving medical devices • Who and how are they regulated
  • 3. What is a medical device • “Medical Device” covers all products, except medicines, used in healthcare for the diagnosis, prevention, monitoring or treatment of illness or disability
  • 4. Examples of medical devices • Implants • Dressings • Patient Monitoring equipment • X ray systems • Wheelchairs • Hearing Aids • Devices for blood glucose measurements
  • 5. Examples of products that can be both a medical device and non medical device • Personal protective equipment • Who are you protecting? • what is the principal stated purpose of the product by the manufacturer? • Rubber/latex gloves • Marigolds = general purpose so not medical device • surgical gloves = medical device
  • 6. Stand alone software • Software which is not incorporated in another medical device but has a medical purpose • Directly controls apparatus (radiotherapy) • Provides immediate decision triggering information (blood glucose meters) • Provides support for healthcare professional (ECG interpretation)
  • 7. Decision tree for standalone software • Is it a computer programme? • Does the programme perform an action on data? • Is it for the benefit of an individual patient - will it evaluate patient data to support or influence the medical care provided to that patient?
  • 8. • Words associated with a medical device • amplify, analysis, interpret, alarms, calculates, controls, converts, detects, diagnose, measures, monitors • Software that applies some sort of automated reasoning - calculation, dose calculation, algorithm, clinicians guide APPs as medical devices
  • 9. • Software that provides personalised guidance • makes use of information entered by the patients, provided by point of care devices or obtained via health records, if it affects the treatment of the patient • If the software performs a calculation or interprets data and the healthcare provider does not review the raw data = medical device
  • 10. Intention to “place on market” Research with the intention to “commercialise” the device or “place on the market” – make available in return for payment or free of charge, with a view to distribution, use or both Requires MHRA approval
  • 11. Manufacturer Person responsible for the design, manufacture, packaging and labelling of a device before it is placed on the market
  • 12. In house manufacture • No intention to “put on the market” or place into service under the manufacturer’s name • There is no transfer of ownership of the product or intention to give to another NHS Trust • Not covered by medical device regulations but may be covered by general research requirements if used in a hospital • Any data gathered cannot be used in a future MHRA submission
  • 13. Working with Addenbrooke’s If the Chief Investigator is an Addenbrooke’s employee or a researcher based at the Clinical School then this MAY be considered “in house” manufacture R&D approval Clinical Engineering approval Electronic safety standards must be met Evidence of liability cover
  • 14. Research in a clinical setting Any study recruiting participants from the NHS, using patient data or patient tissue requires NRES ethics approval and R&D approval Any study using NHS facilities in a study requires R&D approval Any study using NHS staff as participants in a study requires R&D approval and University ethics approval
  • 15. Research with patients • Sponsorship • Confirmation of Funding • Appropriate peer review • Favourable ethical opinion letter • Confirmation of insurance for your study • Confirmation of honorary research contracts • Appropriate agreements with third parties
  • 16. Research Ethics Proof of concept studies recruiting a small number of healthy volunteers – internal ethics approval - but considered on a case by case basis. Studies recruiting a large group of healthy volunteers - no longer a proof of concept study – MHRA assumption that there is an intention to commercialise or “put on market” – NRES ethics approval and MHRA approval Clinical Investigation studies of medical device – NRES ethics approval and may require MHRA approval
  • 17. Insurance Whatever the setting, if you are using a medical device in any type of research, it is important to ensure that appropriate insurance is in place Insurance contact: Victoria Hollamby Victoria.Hollamby@admin.cam.ac.uk
  • 18. Medical devices and regulation • Devices are categorised into classes according to the degree of risk inherent in the device • Class I - low risk – apps, standalone software • Class 11a and 11b – medium risk • Class III high risk • The conformity assessment and the CE mark depend on the Class of the product
  • 19. Classification Depends upon a series of factors including: How long the device is intended to be in continuous use Whether or not the device is invasive Whether the device is implantable or active Whether or not the device contains a substance
  • 20. Non invasive device Class I - In contact with injured skin – provide mechanical barrier, eg plasters, wound gauze Class IIa - Intended to manage micro-environment of wound – control moisture at wound, eg hydrogel dressings. Not for extensive wounds Class IIb - Intended for wounds which breach dermis and heal only by secondary intent – severe burns eg temporary skin substitute
  • 21. Class I If you are satisfied that your medical device complies with the requirements in the MDD, you must write a statement to declare this – “Declaration of Conformity” As 11th February 2015 new online application system for Class I devices, (Device Online Registration System, DORS) .
  • 22. Class IIa and IIb Safety and performance needs to be adequately demonstrated – may need clinical investigation if insufficient existing clinical data
  • 23. Devices requiring clinical investigation Device is implantable or Class III medical device Introducing new concept of device into medical practice Existing device modified so a novel feature may have important phsyiological effects or it affects clinical performance and safety of the device
  • 24. Devices requiring clinical investigation Devices incorporating materials previously untested in humans Device, either CE marked or non CE marked, being proposed for a new purpose or function In vitro and/or animal testing of device cannot mimic the clinical situation New manufacturer, especially of a high risk device
  • 25. Medical Device Directives 90/385/EEC – Active Implantable Device Directive (AIMDD) – covers all powered implants or partial implants that are left in the human body – pacemaker 93/42/EEC – Medical Device Directive (MDD) – covers most other medical devices 98/79/EC – In-vitro Diagnostics Device (IVD) – covers any device which is a reagent, instrument, appparatus, for use in-vitor for examination of speciments from the human body - hepatitis B testing kits
  • 26. Organisations Competent Authority – MHRA Notified Body – CE Marking Ethics – Health Research Authority NRES NHS - R&D
  • 27. MHRA Ensures compliance with regulations Evaluates adverse incident reports Pre-clinical assessment of devices intended for clinical trial Designates the independent certification organisation (notified bodies)
  • 28. Notified Bodies Check manufacturers of medium and high risk devices have followed the requirement Issue CE marks for these devices
  • 29. Useful contacts Research Governance Officer – Carolyn Read cad50@medschl.cam.ac.uk 01223 769291 Research Governance Manager Addenbrooke’s Hospital – Louise Stockley louise.stockley@addenbrookes.nhs.uk