This document describes an experiment conducted to demonstrate and measure fluid flow rates using different flow meter types. The experiment utilized a hydraulic bench unit with a volumetric measuring tank and submersible pump. Three common flow meters were tested: a rotameter, venture meter, and orifice plate. Readings were taken from each meter and calculations were performed to determine flow rates and discharge coefficients. Plots were made comparing actual flow rates to measured rates from each meter. The results showed the relationships between variables and effectiveness of different flow meter designs.