GB - 3
Table of Contents
1.	Preface...............................................................................................................5
1.1	General.................................................................................................................................. 5
1.2	 Safety instructions............................................................................................................... 5
1.3	 Validity and liability.............................................................................................................. 5
1.4	Copyright............................................................................................................................... 6
1.5	 Specified application............................................................................................................ 6
1.6	 Product description.............................................................................................................. 6
1.7	 Part code............................................................................................................................... 7
2.	 Control circuit IO-Link......................................................................................9
2.1	Overview................................................................................................................................ 9
2.1.1	 Inverter status LED1............................................................................................................... 9
2.1.2	 IO-link device interface......................................................................................................... 10
2.1.3	Diagnosis/visualisation......................................................................................................... 10
2.1.3.1	 Assignment of the interface X4A........................................................................................... 10
2.1.3.2	 Connection of the RS232 interface........................................................................................11
2.1.3.3	 Connection of the RS485 interface........................................................................................11
2.1.3.4	 Wiring RS485 full duplex.......................................................................................................11
2.1.3.5	 Wiring RS485 half duplex..................................................................................................... 12
2.1.4	 Control terminal strip X2A..................................................................................................... 13
2.1.4.1	 Assembly of the wires........................................................................................................... 13
2.1.4.2	 Assignment of the terminal strip X2A.................................................................................... 14
2.1.4.3	 Connection of the digital inputs............................................................................................. 15
2.1.4.4	 Connection of the digital outputs.......................................................................................... 16
2.1.4.5	 Connection of the analog inputs........................................................................................... 17
2.1.4.6	 Connection of the analog outputs......................................................................................... 17
2.1.4.7	 Connection of the relay outputs............................................................................................ 18
3.	 Parameter Description...................................................................................19
GB - 4
Table of Contents
GB - 5
Preface
1.	Preface
1.1	General
First we would like to welcome you as a customer of the company Karl E. Brinkmann GmbH
and congratulation to the purchase of this product. You have decided for a product on highest
technical level.
The described hard- and software are developments of the Karl E. Brinkmann GmbH. The
enclosed documents correspond to conditions valid at printing. Misprint, mistakes and techni-
cal changes reserved.
The instruction manual must be made available to the user. Before working with the unit the
user must become familiar with it. This especially applies to the knowledge and observance
of the following safety and warning indications. The used pictograms have following signifi-
cance:
Danger
Is used, if life or health of the user are endangered or sub-
stantial damage to property can occur.
Warning
Caution
Attention
Is used, if a measure is necessary for safe and trouble-free
operation.
observe at
all costs
Information
Is used, if a measure simplifies the handling or operation of
the unit.
Aide
Tip
1.2	 Safety instructions
Observe safety and
operating instruc-
tions
Precondition for all further steps is the knowledge and ob-
servance of the safety and operating instructions (instruction
manual part 1). This is provided accompanied by the device
or by the download site of www.keb.de.
Non-observance of the safety and operating instructions leads to the loss of any liability
claims. The warnings and safety instructions in this manual work only supplementary. This
list is not exhaustive.
1.3	 Validity and liability
The use of our units in the target products is outside of our control and therefore lies
exclusively in the area of responsibility of the machine manufacturer.
The information contained in the technical documentation, as well as any user-specific advice
in spoken and written and through tests, are made to best of our knowledge and information
about the application. However, they are considered for information only without responsibil-
ity. This also applies to any violation of industrial property rights of a third-party.
Selection of our units in view of their suitability for the intended use must be done generally
by the user.
GB - 6
Preface
Tests can only be done within the application by the machine manufacturer. They must be
repeated, even if only parts of hardware, software or the unit adjustment are modified.
Unauthorised opening and tampering may lead to bodily injury and property damage and
may entail the loss of warranty rights. Original spare parts and authorized accessories by the
manufacturer serve as security. The use of other parts excludes liability for the consequences
arising out of.
The suspension of liability is especially valid also for operation interruption loss, loss of profit,
data loss or other damages. This is also valid, if we referred first to the possibility of such
damages.
If single regulations should be or become void, invalid or impracticable, the effectivity of all
other regulations or agreements is not affected.
1.4	Copyright
The customer may use the instruction manual as well as further documents or parts from it for
internal purposes. Copyrights are with KEB and remain valid in its entirety. All rights reserved.
KEB®
, COMBIVERT®
, COMBICONTROL®
and COMBIVIS®
are registered trademarks of Karl
E. Brinkmann GmbH.
Other wordmarks or/and logos are trademarks (™) or registered trademarks (®) of their re-
spective owners and are listed in the footnote on the first occurrence.
When creating our documents we pay attention with the utmost care to the rights of third par-
ties. Should we have not marked a trademark or breach a copyright, please inform us in order
to have the possibility of remedy.
1.5	 Specified application
The COMBIVERT G6 serves exclusively for the control and regulation of three-phase motors.
The operation of other electric consumers is prohibited and can lead to the destruction of the
unit. Frequency inverters are components which are intended for the installation in electric
systems or machines.
The used semiconductors and components of KEB are developed and dimensioned for the
use in industrial products. If the KEB COMBIVERT F5 is used in machines, which work under
exceptional conditions or if essential functions, life-supporting measures or an extraordinary
safety step must be fulfilled, the necessary reliability and security must be ensured by the ma-
chine builder. The operation of our products outside the indicated limit values of the technical
data leads to the loss of any liability claims.
1.6	 Product description
The product family COMBIVERT G6 has been developed for the universal use at open-loop
three-phase drives. The COMBIVERT G6 can be operated open-loop or encoderless speed
or torque-controlled. The units are equipped with an integrated EMC filter.
GB - 7
Preface
This accompanying instruction manual contains only information for the installa-
tion and connection of the IO-Link control of the KEB COMBIVERT G6.
Further parts of the installation manual are required depending on the ordered
type:
• Connection and adjustments of the power unit
• Safety function STO
• Safe digital output for f=0Hz
A manual with general safety requirements and EMC conform installation is
available under www.keb.de.
1.7	 Part code
xx G6 x x x - x x x x
Cooling (not valid for customer-/special version)
0 Air-cooling (housing C, D, E); air-cooling/flat rear (housing A, B)
1 Flat rear
Control/keyboard/display (not valid for customer-/special version)
0 Open-loop without keyboard/display A like 0 on ASCL hardware
1 Open-loop with keyboard/display B like 1 on ASCL hardware
2 SCL without keyboard/display
3 SCL with keyboard/display
4 ASCL without keyboard/display
5 ASCL with keyboard/display
Switching frequency; short time current limit; overcurrent cut-off
(not valid at customer/special version)
0 2 kHz 125 % 150 % 1 4 kHz 125 % 150 %
2 8 kHz 125 % 150 % 3 16 kHz 125 % 150 %
4 2 kHz 150 % 180 % 5 4 kHz 150 % 180 %
6 8 kHz 150 % 180 % 7 16 kHz 150 % 180 %
8 2 kHz 180 % 216 % 9 4 kHz 180 % 216 %
A 8 kHz 180 % 216 % B 2 kHz 180 % 216 %
Voltage, connection
0 1-phase 230 V AC/DC 3 3-phase 400 V AC/DC
1 3-phase 230 V AC/DC 5 400 V DC
2 1/3-phase 230 V AC/DC 6 1-phase 230 V AC
A-Z Customer-/special version (firmware and download)
Housing type A, B, C, D, E
Variants
further on next side
GB - 8
Preface
xx G6 x x x - x x x x
0
without filter, without braking transis-
tor,
without safety function STO
A
like 0 with
STO
H
like A with
f=0Hz
1
without filter, with braking transistor,
without safety function STO
B
like 1 with
STO
I
like B with
f=0Hz
2
internal filter; without braking tran-
sistor, without safety function STO
C
like 2 with
STO
K
like C with
f=0Hz
3
internal filter, with braking transistor,
without safety function STO
D
like 3 with
STO
L
like D with
f=0Hz
Control type
C Analog/digital (standard)
GB CAN® 1
E IO-Link® 2
F EtherCAT® 3
G PROFINET® 4
G6 unit type
Inverter size
1
	CANopen®
is registered trademark of CAN in AUTOMATION - International Users and Manufacturers Group
e.V.
2
	IO-LINK®
is registered trademark of PROFIBUS user organisation e.V.
3
	EtherCAT®
is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Ger-
many
4
	PROFINET®
is registered trademark by Siemens AG
GB - 9
Control circuit
2.	 Control circuit IO-Link
The control provides the following functions:
• IO-link device interface
• Hardware allocation of digital inputs and outputs
• Diagnostic interface (parameter display, scope mode)
• Hardware of the control circuit „safely separated“ according to EN 61800-5-1 (base TN-
C/-S mains)
• LED for inverter state
• Provide allocation of power module parameters for the parameterization for not voltage
supplied power module.
• optional with safety function STO (separate manual)
• optional f=0 Hz functionality (separate manual)
2.1	 Overview
No. Name Description
5
4
3
1
2
31
32
1
2
X2B
X2A
X4AX4B
LED1
1 X4B IO-link device interface
2 X4A Diagnostic interface
3 X2B Safety function STO
4 X2A Control terminal strip
5 LED1 Inverter status
2.1.1	 Inverter status LED1
Pattern Function
off Unit switched off
on Unit ready for operation
flashing Unit in malfunction
GB - 10
Control circuit
2.1.2	 IO-link device interface
X4B PIN Name Function
1 L+ Voltage input
18…30 Vdc / 500 mA
2 C/Q Transmission signal
Input: 18…30 Vdc Ri:10…40 kΩ
Output: 18…30 Vdc I: 220…480 mA
3 L- 0V
Baud rate: 38.4 kBd
Accuracy of the transmission speed: ±0,16 %
Bus and operator supply voltage are not isolated.
Mechanical specification of the terminal block X4B
Connection cross-section 0.2…1.5 mm² 26-16 AWG
Stripping length 10 mm 0.4 inch
Screwdriver blade 0.4 x 2.5
Other Use wire-end ferrules as round, square or hexagon
pressing.
2.1.3	 Diagnosis/visualisation
The integrated RS232/485 interface serves for the connection of service tools (e.g. COM-
BIVIS) and displays. Telegram DIN66019II is used as communication protocol.
The correct configuration and language file must be loaded for the operation with
COMBIVIS. The download can be done via the KEB homepage.
Interface Standard Connecting cable
RS485 TIA/EIA-485 and ISO 8482
RS232 ANSI TIA/EIA-232 0058025-001D
RS232/USB 0058060-0020
2.1.3.1	 Assignment of the interface X4A
54321
9876
54321
9876
reserved 1 6 reserved
TxD (RS232) 2 7 DGND (reference potential)
RxD (RS232) 3 8 TxD-A (RS485)
RxD-A (RS485) 4 9 TxD-B (RS485)
RxD-B (RS485) 5
GB - 11
Control circuit
2.1.3.2	 Connection of the RS232 interface
A RS232 cable is required to connect the control board with a PC. Transmission rate of
1.2…100 kBaud is possible.
Serial cable to connect the control board with a PC
0058025-001D
1
5
6
9
1
5
6
9
2.1.3.3	 Connection of the RS485 interface
The following instructions must be observed in order to prevent interferences at
the RS485 interface:
•	 use in pairs, twisted and shielded cable
•	 Ground outer shield at one side (prior at interference-free side)
•	 Connect terminating resistors (120 Ω) at both ends on pair of wires of the
communication bus
•	 if available, the internal shielding must be laid at the transmitter to ground
•	 Lay earth cable between the bus nodes
A biasing can be used if there are still interferences. However, this should be
done only once at the communication bus (preferably at the master).
2.1.3.4	 Wiring RS485 full duplex
5 4 3 2 1
9 8 7 6
COMBIVERT
5 4 3 2 1
9 8 7 6
COMBIVERT
4 5 8 9 4 5 77 8 9
Master
TxD-A
TxD-B
RxD-A
RxD-B
R R
R
R
R=120Ω
1)
1) The ground connection is used to reduce communication disturbances
GB - 12
Control circuit
2.1.3.5	 Wiring RS485 half duplex
5 4 3 2 1
9 8 7 6
COMBIVERT
4 58 9
5 4 3 2 1
9 8 7 6
COMBIVERT
4 58 9
Master
RXD/TxD-A
RXD/TxD-B
R
R
R=120Ω
77
1)
1) The ground connection is used to reduce communication disturbances
Although the functional earth is connected correctly potential differences be-
tween the bus nodes can occur at long lines which disturb the communica-
tion. To avoid the interface from destruction by high circulating current based
on this, potential differences can be reduced by connection of an additionally
ground line between the controls (0V terminal). To avoid interference coupling
into the signal line, lay these additionally ground cable outside of the bus line !
GB - 13
Control circuit
2.1.4	 Control terminal strip X2A
The control terminal strip is designed as a double, plug-in terminal strip with spring cage con-
nection. It contains 32 pole. The following instructions must be observed at connection:
Attention Prevent EMC malfunctions
• Use shielded / drilled cables
• Lay shield on one side of the inverter onto earth potential
• Lay control and power cable separately (about 10...20 cm apart); Lay
crossings in a right angle (in case it cannot be prevented)
2.1.4.1	 Assembly of the wires
Required tools:
Screw driver SD 0.4 x 2.5 (DIN 5264)
1. Strip cable
Cable permissible cross-section
rigid and flexible 0.13…1 mm2
(AWG28…18)
Use wire-end ferrules as round, square or hexagon press-
ing.
7mm
2. Plug screw driver mid into the square slot
3. Plug cable into the round slot, that no wires can be seen
from the outside.
4. Remove screw driver and check if cables are fixed.
GB - 14
Control circuit
2.1.4.2	 Assignment of the terminal strip X2A
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31
PIN Name Description Specifications
1 0V Digital mass; Reference potential for digital inputs/outputs and Uin
2 Uin
Input external voltage supply U=24 VDC +20 %/-15 %
Imax
=400 mA
3 0V like pin 1
4 Uout
Voltage output for the control of the digital
inputs
U=24 VDC ±25 %
Imax
=100 mA
5 RST reset
8 digital inputs according to IEC61131-2 type
1
„0“ = -3…5 VDC
„1“ = 15…30 VDC
Scan time ≤ 2 ms
6 ST 1)
Control release
7 R Direction of rotation re-
verse
8 F Direction of rotation for-
ward
9 I2 Digital input 2
10 I1 Digital input 1
11 I4 Digital input 4
12 I3 Digital input 3
13 O2 Digital output 2 2 digital transistor outputs PNP
U=24 VDC ±25 %
Imax
=50 mA ohmic load for O1+O2
max switching frequency = 250 Hz
14 O1 Digital output 1
15 0V like pin 1
16 CRF Reference voltage for
setpoint potentiometer
10 VDC +5 %; Imax
= 4 mA
17 AN1- -Analog input 1 adjustable:
0…±10 V (Ri
=55 kΩ)
0…±20 mA (Ri
=250 Ω)
4…20 mA (Ri
=250 Ω)
Resolution: 10 Bit + sign
Scan time ≤ 2 ms
18 AN1+ +Analog input 1
19 AN2- -Analog input 2
20 AN2+ +Analog input 2
further on next side
GB - 15
Control circuit
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31
PIN Name Description Specifications
21 COM Analog mass; Reference potential for analog inputs and outputs
22 ANOUT1 Analog output 1 U=0…±10 VDC (max. 11.5 VDC)
Imax
=10 mA
Ri = 100 Ω
Resolution= 11Bit + sign
23 COM like Pin 21
24 ANOUT2 Analog output 2 like Pin 22
25 R2-C Relay 2 Switching contact
Umax 
= 30 V DC
I = 0.01…1 A
Ohmic load
26 R1-C Relay 1 Switching contact
27 R2-B Relay 2 NC contact
28 R1-B Relay 1 NC contact
29 R2-A Relay 2 NO contact
30 R1A Relay 1 NO contact
31 R3-C 2)
Relay 3 switching contact f=0 Hz is described in a sepa-
rate manual32 R3-A 2)
Relay 3 no contact f = 0 Hz
1) The control release (terminal ST) is without function for units with safety function STO.
2) Relay 3 is only equipped at the version with 0Hz functionality. The function is described in
a separate manual.
2.1.4.3	 Connection of the digital inputs
Connection of the digital inputs
with internal voltage supply with external voltage supply
12
11
6 8 10
5
4
3 7 9
12
11
6 8 10
5
4
3 7 9
+
GB - 16
Control circuit
Input Factory setting of the digital inputs
Name PIN open-loop operation closed-loop operation
RST 5 reset
ST 6 Control release
R 7 Direction of rotation reverse
F 8 Direction of rotation forward
I1 10 Fixed
frequency 1 Fixed
frequency 3
Fixed value 1
Fixed value 3
I2 9 Fixed
frequency 2
Fixed value 2
I3 12 External error input (E.EF)
I4 11 Activates the DC braking –
2.1.4.4	 Connection of the digital outputs
Examples for the connection of the digital outputs
Connection appliance Connection to an external control
1513
14
1513
14
COMDI1DI2
Example for the control of digital inputs and outputs
5 73 9 1113
6 84 101214
Output
Factory setting of the digital outputs
Name PIN
O1 14 Switches at actual value=setpoint
O2 13 Ready signal
GB - 17
Control circuit
2.1.4.5	 Connection of the analog inputs
Examples for the connection of the analog setpoint input
2022
19
18
17
16
15 21
R = 0…3/5/10kΩ
2022
19
18
17 21
+
*)
0…±10Vdc
18
17
+
0…±20mA
4…20mA
*) Connect potential equalizing line only if a potential difference of >30 V exists
between the controls. The internal resistance is reduced to 30 kΩ.
Input
Factory setting of the setpoint inputs
Name PIN
AN1 17/18 analog setpoint setting 0…±10 Vdc
AN2 19/20 –
2.1.4.6	 Connection of the analog outputs
Connection of the analog outputs
2321
2224
Imax=10mA
0…10Vdc
Imax=10mA
0…10Vdc
Output Factory setting of the analog outputs
Name PIN open-loop operation closed-loop operation
AO1 22 Actual value display (CP01)
0…±400 Hz
Actual value display (CP01)
0…±4000 rpm
AO2 24 Apparent current 0…2•IoutN
GB - 18
Control circuit
2.1.4.7	 Connection of the relay outputs
Connection of the relay outputs
262830
252729
R2
R1
Specification:
U = max. 30 Vdc
I = 0.01…1 A
Ohmic load
Output Factory setting of the relay outputs
Name PIN open-loop operation closed-loop operation
R1 26/28/30 Fault relay
R2 25/27/29 Frequency-dependent switch Run signal
GB - 19
Parameter Description
3.	 Parameter Description
On delivery the KEB COMBIVERT G6 is assigned with an user menu, the customer parame-
ters (CP-Parameters). These represent a selection of important parameters for the operation.
Up to a maximum of 48 customer parameters can be defined from over 500 parameters.
Only parameter CP00 password input is predefined and can not be modified or deleted.
Depending on the unit, there are three different customer parameter menus:
• for open-loop operation 00G6N1B-C000
• for ASCL operation 00G6N1B-H000
• for SCL operation 00G6N1B-J000
The menu to be used can be determined from parameter CP48 (see below).
	
	 CP48	 Software version
Co-domain Setting Description
0.0.0.0 … F.F.F.F – Display of the software version
The first two digits display the major and minor version number (e.g.
1.2.x.x => V1.2)
The third digit displays the power unit software
x.x.0.x Power unit open-loop 1st version
x.x.1.x Power unit open-loop 2nd version
x.x.2.x Power unit ASCL
x.x.3.x Power unit SCL
The fourth digit displays a serial number for the date code.
KEB Antriebstechnik Austria GmbH
Ritzstraße 8 • A-4614 Marchtrenk
fon: +43 7243 53586-0 • fax: +43 7243 53586-21
net: www.keb.at • mail: info@keb.at
KEB Antriebstechnik
Herenveld 2 • B-9500 Geraadsbergen
fon: +32 5443 7860 • fax: +32 5443 7898
mail: vb.belgien@keb.de
KEB Power Transmission Technology (Shanghai) Co.,Ltd.
No. 435 Qianpu Road, Chedun Town, Songjiang District,
CHN-Shanghai 201611, P.R. China
fon: +86 21 37746688 • fax: +86 21 37746600
net: www.keb.cn • mail: info@keb.cn
KEB Antriebstechnik Austria GmbH
Organizační složka
K. Weise 1675/5 • CZ-370 04 České Budějovice
fon: +420 387 699 111 • fax: +420 387 699 119
net: www.keb.cz • mail: info.keb@seznam.cz
KEB Antriebstechnik GmbH
Wildbacher Str. 5 • D–08289 Schneeberg
fon: +49 3772 67-0 • fax: +49 3772 67-281
mail: info@keb-drive.de
KEB España
C/ Mitjer, Nave 8 - Pol. Ind. LA MASIA
E-08798 Sant Cugat Sesgarrigues (Barcelona)
fon: +34 93 897 0268 • fax: +34 93 899 2035
mail: vb.espana@keb.de
Société Française KEB
Z.I. de la Croix St. Nicolas • 14, rue Gustave Eiffel
F-94510 LA QUEUE EN BRIE
fon: +33 1 49620101 • fax: +33 1 45767495
net: www.keb.fr • mail: info@keb.fr
KEB (UK) Ltd.
6 Chieftain Buisiness Park, Morris Close
Park Farm, Wellingborough GB-Northants, NN8 6 XF
fon: +44 1933 402220 • fax: +44 1933 400724
net: www.keb-uk.co.uk • mail: info@keb-uk.co.uk
KEB Italia S.r.l.
Via Newton, 2 • I-20019 Settimo Milanese (Milano)
fon: +39 02 3353531 • fax: +39 02 33500790
net: www.keb.it • mail: kebitalia@keb.it
KEB Japan Ltd.
15–16, 2–Chome, Takanawa Minato-ku
J–Tokyo 108-0074
fon: +81 33 445-8515 • fax: +81 33 445-8215
mail: info@keb.jp
KEB Korea Seoul
Room 1709, 415 Missy 2000
725 Su Seo Dong, Gang Nam Gu
ROK-135-757 Seoul/South Korea
fon: +82 2 6253 6771 • fax: +82 2 6253 6770
mail: vb.korea@keb.de
KEB RUS Ltd.
Lesnaya Str. House 30, Dzerzhinsky (MO)
RUS-140091 Moscow region
fon: +7 495 550 8367 • fax: +7 495 632 0217
net: www.keb.ru • mail: info@keb.ru
KEB Sverige
Box 265 (Bergavägen 19)
S-43093 Hälsö
fon: +46 31 961520 • fax: +46 31 961124
mail: vb.schweden@keb.de
KEB America, Inc.
5100 Valley Industrial Blvd. South
USA-Shakopee, MN 55379
fon: +1 952 224-1400 • fax: +1 952 224-1499
net: www.kebamerica.com • mail: info@kebamerica.com
© KEB
Mat.No. 00G6NES-E000
Rev. 1D
Date 03/2013
More and newest addresses at http://www.keb.de
Karl E. Brinkmann GmbH
Försterweg 36-38 • D-32683 Barntrup
fon: +49 5263 401-0 • fax: +49 5263 401-116
net: www.keb.de • mail: info@keb.de
KEB worldwide…

More Related Content

PDF
Catalogue biến tần Siemens V20 - đại lý biến tần siemens v20
PDF
Series 501 Hornet Cold Cathode Miniature-Ionization Vacuum Gauge
PDF
Siemens s7 300-400-integrated function mudule
PDF
Siemens s7 300-400-hb-cpu31x_c_und_cpu31x_e
PDF
Beetle / Express operating manual (english)
PDF
1 fk7 1011_eng_en-us
PDF
Instruction Manual ARMASIGHT Mount AIM PRO, AIM PRO-L | Optics Trade
PDF
KT800 English user manual paperless recorder
Catalogue biến tần Siemens V20 - đại lý biến tần siemens v20
Series 501 Hornet Cold Cathode Miniature-Ionization Vacuum Gauge
Siemens s7 300-400-integrated function mudule
Siemens s7 300-400-hb-cpu31x_c_und_cpu31x_e
Beetle / Express operating manual (english)
1 fk7 1011_eng_en-us
Instruction Manual ARMASIGHT Mount AIM PRO, AIM PRO-L | Optics Trade
KT800 English user manual paperless recorder

What's hot (13)

PDF
Commander sx user guide
PDF
Tài liệu hướng dẫn cài đặt biến tần Siemens Sinamic G120
PDF
Fb1200 instruction manual
PDF
2 ai i_2_4wire_hf_manual_en-us
PDF
Deutz fahr 914 engine service repair manual
PDF
Siemens catalog hmi-tp070 touch panel
PDF
Siemens catalog hmi-tp070_e
PDF
Deutz fahr tcd 2012 2 v engine service repair manual
PDF
Sipart ps 2
PDF
Guide to-industrial-control-panels
PDF
Siemens s7 300-400-hb-cpu312_ifm_bis_318-2dp_e
PDF
JCB 801.4 MINI EXCAVATOR Service Repair Manual SN(720001 Onwards)
PDF
Deutz 2009 engine service repair manual
Commander sx user guide
Tài liệu hướng dẫn cài đặt biến tần Siemens Sinamic G120
Fb1200 instruction manual
2 ai i_2_4wire_hf_manual_en-us
Deutz fahr 914 engine service repair manual
Siemens catalog hmi-tp070 touch panel
Siemens catalog hmi-tp070_e
Deutz fahr tcd 2012 2 v engine service repair manual
Sipart ps 2
Guide to-industrial-control-panels
Siemens s7 300-400-hb-cpu312_ifm_bis_318-2dp_e
JCB 801.4 MINI EXCAVATOR Service Repair Manual SN(720001 Onwards)
Deutz 2009 engine service repair manual
Ad

Viewers also liked (17)

PDF
Vfd b manual-en
PDF
Vfd m en_20100514
PDF
Atv16 ang
PDF
En acq810 fw manual b
PDF
PDF
Vf s15 intruction manual
PDF
F4 s c_instruction manual
PDF
I s7 eng_101201
PDF
Sv i s5 user manual-100520
PDF
410 opi 21742069_en_0705
PDF
Delta vfd dd-m_en_20120614
PDF
Unidrive m100 m101 sheet issue
PDF
Vfd ve m-en_20081231
PDF
Uni sp advanced_ug_iss10
PDF
Chv180 series new
PDF
Atv32 programming manual
PDF
Atv312 programming manual
Vfd b manual-en
Vfd m en_20100514
Atv16 ang
En acq810 fw manual b
Vf s15 intruction manual
F4 s c_instruction manual
I s7 eng_101201
Sv i s5 user manual-100520
410 opi 21742069_en_0705
Delta vfd dd-m_en_20120614
Unidrive m100 m101 sheet issue
Vfd ve m-en_20081231
Uni sp advanced_ug_iss10
Chv180 series new
Atv32 programming manual
Atv312 programming manual
Ad

Similar to G6 io instruction manual (20)

PDF
F6 instruction manual
PDF
F5 m instruction manual
PDF
F5 b c_g_instruction manual
PDF
SOLAR PUMP INVERTER MANUAL
PDF
F4 f instruction manual
PDF
THE MAXIMUM FREQUENCY OF SERIES INVERTER IS RESTRICTED TO THE
PDF
F4 s instruction manual
PDF
Datasheet r7 m a10030_s1
PDF
Omron catalog bientan-omron_3g3jx
PDF
Kde200 user manual
PDF
PDF
Manual e5 cn omrom
PDF
安川A1000系列英文版
PDF
Bernini ATM910.pdf
PDF
Elmo motion control- industrial products catalog
PDF
Scart manual
PDF
Scart manual
PDF
Econom 0_ 01_ 1_ 2 - Operating instruction - Active facades_ Industrial use.pdf
PDF
ABB Sami GS 501 Manual
F6 instruction manual
F5 m instruction manual
F5 b c_g_instruction manual
SOLAR PUMP INVERTER MANUAL
F4 f instruction manual
THE MAXIMUM FREQUENCY OF SERIES INVERTER IS RESTRICTED TO THE
F4 s instruction manual
Datasheet r7 m a10030_s1
Omron catalog bientan-omron_3g3jx
Kde200 user manual
Manual e5 cn omrom
安川A1000系列英文版
Bernini ATM910.pdf
Elmo motion control- industrial products catalog
Scart manual
Scart manual
Econom 0_ 01_ 1_ 2 - Operating instruction - Active facades_ Industrial use.pdf
ABB Sami GS 501 Manual

More from Toàn Huỳnh (20)

PDF
Fr f700
PDF
Ct2000 v english_ver 1.36
PDF
Ct2000 pro plus_manual_english[1]
PDF
Ct2000 f manual_english
PDF
Ct2000 ev manual_english_version 1.1
PDF
Ct2000 es manual_english_version_1[1].0
PDF
En acs880 fw_man_d
PDF
En acs800 standard_fw_l
PDF
En acs150 um rev c_a4_screen
PDF
En ach550 01_um_f_a4_lo_screenres
PDF
En 600stdprg fwmanual
PDF
Acs550 x1-rev e
PDF
Acs550 02-us-04
PDF
PDF
Abb acs850-04-firmware-manual
PDF
Abb acs310-users-guide
PDF
Abb acs55-users-guide
PDF
Sv i p5a-manual_(english)
PDF
PDF
I v5 eng_110526
Fr f700
Ct2000 v english_ver 1.36
Ct2000 pro plus_manual_english[1]
Ct2000 f manual_english
Ct2000 ev manual_english_version 1.1
Ct2000 es manual_english_version_1[1].0
En acs880 fw_man_d
En acs800 standard_fw_l
En acs150 um rev c_a4_screen
En ach550 01_um_f_a4_lo_screenres
En 600stdprg fwmanual
Acs550 x1-rev e
Acs550 02-us-04
Abb acs850-04-firmware-manual
Abb acs310-users-guide
Abb acs55-users-guide
Sv i p5a-manual_(english)
I v5 eng_110526

Recently uploaded (20)

PDF
Diabetes mellitus diagnosis method based random forest with bat algorithm
PDF
Per capita expenditure prediction using model stacking based on satellite ima...
PPT
Teaching material agriculture food technology
PDF
Empathic Computing: Creating Shared Understanding
PDF
7 ChatGPT Prompts to Help You Define Your Ideal Customer Profile.pdf
PDF
Building Integrated photovoltaic BIPV_UPV.pdf
PDF
Encapsulation_ Review paper, used for researhc scholars
PDF
Agricultural_Statistics_at_a_Glance_2022_0.pdf
PDF
Optimiser vos workloads AI/ML sur Amazon EC2 et AWS Graviton
PDF
TokAI - TikTok AI Agent : The First AI Application That Analyzes 10,000+ Vira...
PPTX
SOPHOS-XG Firewall Administrator PPT.pptx
PDF
Approach and Philosophy of On baking technology
PPTX
Machine Learning_overview_presentation.pptx
PDF
Encapsulation theory and applications.pdf
PDF
Dropbox Q2 2025 Financial Results & Investor Presentation
PDF
gpt5_lecture_notes_comprehensive_20250812015547.pdf
PDF
Network Security Unit 5.pdf for BCA BBA.
PPTX
Digital-Transformation-Roadmap-for-Companies.pptx
PDF
cuic standard and advanced reporting.pdf
PDF
MIND Revenue Release Quarter 2 2025 Press Release
Diabetes mellitus diagnosis method based random forest with bat algorithm
Per capita expenditure prediction using model stacking based on satellite ima...
Teaching material agriculture food technology
Empathic Computing: Creating Shared Understanding
7 ChatGPT Prompts to Help You Define Your Ideal Customer Profile.pdf
Building Integrated photovoltaic BIPV_UPV.pdf
Encapsulation_ Review paper, used for researhc scholars
Agricultural_Statistics_at_a_Glance_2022_0.pdf
Optimiser vos workloads AI/ML sur Amazon EC2 et AWS Graviton
TokAI - TikTok AI Agent : The First AI Application That Analyzes 10,000+ Vira...
SOPHOS-XG Firewall Administrator PPT.pptx
Approach and Philosophy of On baking technology
Machine Learning_overview_presentation.pptx
Encapsulation theory and applications.pdf
Dropbox Q2 2025 Financial Results & Investor Presentation
gpt5_lecture_notes_comprehensive_20250812015547.pdf
Network Security Unit 5.pdf for BCA BBA.
Digital-Transformation-Roadmap-for-Companies.pptx
cuic standard and advanced reporting.pdf
MIND Revenue Release Quarter 2 2025 Press Release

G6 io instruction manual

  • 1. C O M B I V E R T GB Installation Manual IO-link Control Circuit Original manual Mat.No. Rev. 00G6NES-E000 1D
  • 3. GB - 3 Table of Contents 1. Preface...............................................................................................................5 1.1 General.................................................................................................................................. 5 1.2 Safety instructions............................................................................................................... 5 1.3 Validity and liability.............................................................................................................. 5 1.4 Copyright............................................................................................................................... 6 1.5 Specified application............................................................................................................ 6 1.6 Product description.............................................................................................................. 6 1.7 Part code............................................................................................................................... 7 2. Control circuit IO-Link......................................................................................9 2.1 Overview................................................................................................................................ 9 2.1.1 Inverter status LED1............................................................................................................... 9 2.1.2 IO-link device interface......................................................................................................... 10 2.1.3 Diagnosis/visualisation......................................................................................................... 10 2.1.3.1 Assignment of the interface X4A........................................................................................... 10 2.1.3.2 Connection of the RS232 interface........................................................................................11 2.1.3.3 Connection of the RS485 interface........................................................................................11 2.1.3.4 Wiring RS485 full duplex.......................................................................................................11 2.1.3.5 Wiring RS485 half duplex..................................................................................................... 12 2.1.4 Control terminal strip X2A..................................................................................................... 13 2.1.4.1 Assembly of the wires........................................................................................................... 13 2.1.4.2 Assignment of the terminal strip X2A.................................................................................... 14 2.1.4.3 Connection of the digital inputs............................................................................................. 15 2.1.4.4 Connection of the digital outputs.......................................................................................... 16 2.1.4.5 Connection of the analog inputs........................................................................................... 17 2.1.4.6 Connection of the analog outputs......................................................................................... 17 2.1.4.7 Connection of the relay outputs............................................................................................ 18 3. Parameter Description...................................................................................19
  • 4. GB - 4 Table of Contents
  • 5. GB - 5 Preface 1. Preface 1.1 General First we would like to welcome you as a customer of the company Karl E. Brinkmann GmbH and congratulation to the purchase of this product. You have decided for a product on highest technical level. The described hard- and software are developments of the Karl E. Brinkmann GmbH. The enclosed documents correspond to conditions valid at printing. Misprint, mistakes and techni- cal changes reserved. The instruction manual must be made available to the user. Before working with the unit the user must become familiar with it. This especially applies to the knowledge and observance of the following safety and warning indications. The used pictograms have following signifi- cance: Danger Is used, if life or health of the user are endangered or sub- stantial damage to property can occur. Warning Caution Attention Is used, if a measure is necessary for safe and trouble-free operation. observe at all costs Information Is used, if a measure simplifies the handling or operation of the unit. Aide Tip 1.2 Safety instructions Observe safety and operating instruc- tions Precondition for all further steps is the knowledge and ob- servance of the safety and operating instructions (instruction manual part 1). This is provided accompanied by the device or by the download site of www.keb.de. Non-observance of the safety and operating instructions leads to the loss of any liability claims. The warnings and safety instructions in this manual work only supplementary. This list is not exhaustive. 1.3 Validity and liability The use of our units in the target products is outside of our control and therefore lies exclusively in the area of responsibility of the machine manufacturer. The information contained in the technical documentation, as well as any user-specific advice in spoken and written and through tests, are made to best of our knowledge and information about the application. However, they are considered for information only without responsibil- ity. This also applies to any violation of industrial property rights of a third-party. Selection of our units in view of their suitability for the intended use must be done generally by the user.
  • 6. GB - 6 Preface Tests can only be done within the application by the machine manufacturer. They must be repeated, even if only parts of hardware, software or the unit adjustment are modified. Unauthorised opening and tampering may lead to bodily injury and property damage and may entail the loss of warranty rights. Original spare parts and authorized accessories by the manufacturer serve as security. The use of other parts excludes liability for the consequences arising out of. The suspension of liability is especially valid also for operation interruption loss, loss of profit, data loss or other damages. This is also valid, if we referred first to the possibility of such damages. If single regulations should be or become void, invalid or impracticable, the effectivity of all other regulations or agreements is not affected. 1.4 Copyright The customer may use the instruction manual as well as further documents or parts from it for internal purposes. Copyrights are with KEB and remain valid in its entirety. All rights reserved. KEB® , COMBIVERT® , COMBICONTROL® and COMBIVIS® are registered trademarks of Karl E. Brinkmann GmbH. Other wordmarks or/and logos are trademarks (™) or registered trademarks (®) of their re- spective owners and are listed in the footnote on the first occurrence. When creating our documents we pay attention with the utmost care to the rights of third par- ties. Should we have not marked a trademark or breach a copyright, please inform us in order to have the possibility of remedy. 1.5 Specified application The COMBIVERT G6 serves exclusively for the control and regulation of three-phase motors. The operation of other electric consumers is prohibited and can lead to the destruction of the unit. Frequency inverters are components which are intended for the installation in electric systems or machines. The used semiconductors and components of KEB are developed and dimensioned for the use in industrial products. If the KEB COMBIVERT F5 is used in machines, which work under exceptional conditions or if essential functions, life-supporting measures or an extraordinary safety step must be fulfilled, the necessary reliability and security must be ensured by the ma- chine builder. The operation of our products outside the indicated limit values of the technical data leads to the loss of any liability claims. 1.6 Product description The product family COMBIVERT G6 has been developed for the universal use at open-loop three-phase drives. The COMBIVERT G6 can be operated open-loop or encoderless speed or torque-controlled. The units are equipped with an integrated EMC filter.
  • 7. GB - 7 Preface This accompanying instruction manual contains only information for the installa- tion and connection of the IO-Link control of the KEB COMBIVERT G6. Further parts of the installation manual are required depending on the ordered type: • Connection and adjustments of the power unit • Safety function STO • Safe digital output for f=0Hz A manual with general safety requirements and EMC conform installation is available under www.keb.de. 1.7 Part code xx G6 x x x - x x x x Cooling (not valid for customer-/special version) 0 Air-cooling (housing C, D, E); air-cooling/flat rear (housing A, B) 1 Flat rear Control/keyboard/display (not valid for customer-/special version) 0 Open-loop without keyboard/display A like 0 on ASCL hardware 1 Open-loop with keyboard/display B like 1 on ASCL hardware 2 SCL without keyboard/display 3 SCL with keyboard/display 4 ASCL without keyboard/display 5 ASCL with keyboard/display Switching frequency; short time current limit; overcurrent cut-off (not valid at customer/special version) 0 2 kHz 125 % 150 % 1 4 kHz 125 % 150 % 2 8 kHz 125 % 150 % 3 16 kHz 125 % 150 % 4 2 kHz 150 % 180 % 5 4 kHz 150 % 180 % 6 8 kHz 150 % 180 % 7 16 kHz 150 % 180 % 8 2 kHz 180 % 216 % 9 4 kHz 180 % 216 % A 8 kHz 180 % 216 % B 2 kHz 180 % 216 % Voltage, connection 0 1-phase 230 V AC/DC 3 3-phase 400 V AC/DC 1 3-phase 230 V AC/DC 5 400 V DC 2 1/3-phase 230 V AC/DC 6 1-phase 230 V AC A-Z Customer-/special version (firmware and download) Housing type A, B, C, D, E Variants further on next side
  • 8. GB - 8 Preface xx G6 x x x - x x x x 0 without filter, without braking transis- tor, without safety function STO A like 0 with STO H like A with f=0Hz 1 without filter, with braking transistor, without safety function STO B like 1 with STO I like B with f=0Hz 2 internal filter; without braking tran- sistor, without safety function STO C like 2 with STO K like C with f=0Hz 3 internal filter, with braking transistor, without safety function STO D like 3 with STO L like D with f=0Hz Control type C Analog/digital (standard) GB CAN® 1 E IO-Link® 2 F EtherCAT® 3 G PROFINET® 4 G6 unit type Inverter size 1 CANopen® is registered trademark of CAN in AUTOMATION - International Users and Manufacturers Group e.V. 2 IO-LINK® is registered trademark of PROFIBUS user organisation e.V. 3 EtherCAT® is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Ger- many 4 PROFINET® is registered trademark by Siemens AG
  • 9. GB - 9 Control circuit 2. Control circuit IO-Link The control provides the following functions: • IO-link device interface • Hardware allocation of digital inputs and outputs • Diagnostic interface (parameter display, scope mode) • Hardware of the control circuit „safely separated“ according to EN 61800-5-1 (base TN- C/-S mains) • LED for inverter state • Provide allocation of power module parameters for the parameterization for not voltage supplied power module. • optional with safety function STO (separate manual) • optional f=0 Hz functionality (separate manual) 2.1 Overview No. Name Description 5 4 3 1 2 31 32 1 2 X2B X2A X4AX4B LED1 1 X4B IO-link device interface 2 X4A Diagnostic interface 3 X2B Safety function STO 4 X2A Control terminal strip 5 LED1 Inverter status 2.1.1 Inverter status LED1 Pattern Function off Unit switched off on Unit ready for operation flashing Unit in malfunction
  • 10. GB - 10 Control circuit 2.1.2 IO-link device interface X4B PIN Name Function 1 L+ Voltage input 18…30 Vdc / 500 mA 2 C/Q Transmission signal Input: 18…30 Vdc Ri:10…40 kΩ Output: 18…30 Vdc I: 220…480 mA 3 L- 0V Baud rate: 38.4 kBd Accuracy of the transmission speed: ±0,16 % Bus and operator supply voltage are not isolated. Mechanical specification of the terminal block X4B Connection cross-section 0.2…1.5 mm² 26-16 AWG Stripping length 10 mm 0.4 inch Screwdriver blade 0.4 x 2.5 Other Use wire-end ferrules as round, square or hexagon pressing. 2.1.3 Diagnosis/visualisation The integrated RS232/485 interface serves for the connection of service tools (e.g. COM- BIVIS) and displays. Telegram DIN66019II is used as communication protocol. The correct configuration and language file must be loaded for the operation with COMBIVIS. The download can be done via the KEB homepage. Interface Standard Connecting cable RS485 TIA/EIA-485 and ISO 8482 RS232 ANSI TIA/EIA-232 0058025-001D RS232/USB 0058060-0020 2.1.3.1 Assignment of the interface X4A 54321 9876 54321 9876 reserved 1 6 reserved TxD (RS232) 2 7 DGND (reference potential) RxD (RS232) 3 8 TxD-A (RS485) RxD-A (RS485) 4 9 TxD-B (RS485) RxD-B (RS485) 5
  • 11. GB - 11 Control circuit 2.1.3.2 Connection of the RS232 interface A RS232 cable is required to connect the control board with a PC. Transmission rate of 1.2…100 kBaud is possible. Serial cable to connect the control board with a PC 0058025-001D 1 5 6 9 1 5 6 9 2.1.3.3 Connection of the RS485 interface The following instructions must be observed in order to prevent interferences at the RS485 interface: • use in pairs, twisted and shielded cable • Ground outer shield at one side (prior at interference-free side) • Connect terminating resistors (120 Ω) at both ends on pair of wires of the communication bus • if available, the internal shielding must be laid at the transmitter to ground • Lay earth cable between the bus nodes A biasing can be used if there are still interferences. However, this should be done only once at the communication bus (preferably at the master). 2.1.3.4 Wiring RS485 full duplex 5 4 3 2 1 9 8 7 6 COMBIVERT 5 4 3 2 1 9 8 7 6 COMBIVERT 4 5 8 9 4 5 77 8 9 Master TxD-A TxD-B RxD-A RxD-B R R R R R=120Ω 1) 1) The ground connection is used to reduce communication disturbances
  • 12. GB - 12 Control circuit 2.1.3.5 Wiring RS485 half duplex 5 4 3 2 1 9 8 7 6 COMBIVERT 4 58 9 5 4 3 2 1 9 8 7 6 COMBIVERT 4 58 9 Master RXD/TxD-A RXD/TxD-B R R R=120Ω 77 1) 1) The ground connection is used to reduce communication disturbances Although the functional earth is connected correctly potential differences be- tween the bus nodes can occur at long lines which disturb the communica- tion. To avoid the interface from destruction by high circulating current based on this, potential differences can be reduced by connection of an additionally ground line between the controls (0V terminal). To avoid interference coupling into the signal line, lay these additionally ground cable outside of the bus line !
  • 13. GB - 13 Control circuit 2.1.4 Control terminal strip X2A The control terminal strip is designed as a double, plug-in terminal strip with spring cage con- nection. It contains 32 pole. The following instructions must be observed at connection: Attention Prevent EMC malfunctions • Use shielded / drilled cables • Lay shield on one side of the inverter onto earth potential • Lay control and power cable separately (about 10...20 cm apart); Lay crossings in a right angle (in case it cannot be prevented) 2.1.4.1 Assembly of the wires Required tools: Screw driver SD 0.4 x 2.5 (DIN 5264) 1. Strip cable Cable permissible cross-section rigid and flexible 0.13…1 mm2 (AWG28…18) Use wire-end ferrules as round, square or hexagon press- ing. 7mm 2. Plug screw driver mid into the square slot 3. Plug cable into the round slot, that no wires can be seen from the outside. 4. Remove screw driver and check if cables are fixed.
  • 14. GB - 14 Control circuit 2.1.4.2 Assignment of the terminal strip X2A 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 PIN Name Description Specifications 1 0V Digital mass; Reference potential for digital inputs/outputs and Uin 2 Uin Input external voltage supply U=24 VDC +20 %/-15 % Imax =400 mA 3 0V like pin 1 4 Uout Voltage output for the control of the digital inputs U=24 VDC ±25 % Imax =100 mA 5 RST reset 8 digital inputs according to IEC61131-2 type 1 „0“ = -3…5 VDC „1“ = 15…30 VDC Scan time ≤ 2 ms 6 ST 1) Control release 7 R Direction of rotation re- verse 8 F Direction of rotation for- ward 9 I2 Digital input 2 10 I1 Digital input 1 11 I4 Digital input 4 12 I3 Digital input 3 13 O2 Digital output 2 2 digital transistor outputs PNP U=24 VDC ±25 % Imax =50 mA ohmic load for O1+O2 max switching frequency = 250 Hz 14 O1 Digital output 1 15 0V like pin 1 16 CRF Reference voltage for setpoint potentiometer 10 VDC +5 %; Imax = 4 mA 17 AN1- -Analog input 1 adjustable: 0…±10 V (Ri =55 kΩ) 0…±20 mA (Ri =250 Ω) 4…20 mA (Ri =250 Ω) Resolution: 10 Bit + sign Scan time ≤ 2 ms 18 AN1+ +Analog input 1 19 AN2- -Analog input 2 20 AN2+ +Analog input 2 further on next side
  • 15. GB - 15 Control circuit 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 PIN Name Description Specifications 21 COM Analog mass; Reference potential for analog inputs and outputs 22 ANOUT1 Analog output 1 U=0…±10 VDC (max. 11.5 VDC) Imax =10 mA Ri = 100 Ω Resolution= 11Bit + sign 23 COM like Pin 21 24 ANOUT2 Analog output 2 like Pin 22 25 R2-C Relay 2 Switching contact Umax  = 30 V DC I = 0.01…1 A Ohmic load 26 R1-C Relay 1 Switching contact 27 R2-B Relay 2 NC contact 28 R1-B Relay 1 NC contact 29 R2-A Relay 2 NO contact 30 R1A Relay 1 NO contact 31 R3-C 2) Relay 3 switching contact f=0 Hz is described in a sepa- rate manual32 R3-A 2) Relay 3 no contact f = 0 Hz 1) The control release (terminal ST) is without function for units with safety function STO. 2) Relay 3 is only equipped at the version with 0Hz functionality. The function is described in a separate manual. 2.1.4.3 Connection of the digital inputs Connection of the digital inputs with internal voltage supply with external voltage supply 12 11 6 8 10 5 4 3 7 9 12 11 6 8 10 5 4 3 7 9 +
  • 16. GB - 16 Control circuit Input Factory setting of the digital inputs Name PIN open-loop operation closed-loop operation RST 5 reset ST 6 Control release R 7 Direction of rotation reverse F 8 Direction of rotation forward I1 10 Fixed frequency 1 Fixed frequency 3 Fixed value 1 Fixed value 3 I2 9 Fixed frequency 2 Fixed value 2 I3 12 External error input (E.EF) I4 11 Activates the DC braking – 2.1.4.4 Connection of the digital outputs Examples for the connection of the digital outputs Connection appliance Connection to an external control 1513 14 1513 14 COMDI1DI2 Example for the control of digital inputs and outputs 5 73 9 1113 6 84 101214 Output Factory setting of the digital outputs Name PIN O1 14 Switches at actual value=setpoint O2 13 Ready signal
  • 17. GB - 17 Control circuit 2.1.4.5 Connection of the analog inputs Examples for the connection of the analog setpoint input 2022 19 18 17 16 15 21 R = 0…3/5/10kΩ 2022 19 18 17 21 + *) 0…±10Vdc 18 17 + 0…±20mA 4…20mA *) Connect potential equalizing line only if a potential difference of >30 V exists between the controls. The internal resistance is reduced to 30 kΩ. Input Factory setting of the setpoint inputs Name PIN AN1 17/18 analog setpoint setting 0…±10 Vdc AN2 19/20 – 2.1.4.6 Connection of the analog outputs Connection of the analog outputs 2321 2224 Imax=10mA 0…10Vdc Imax=10mA 0…10Vdc Output Factory setting of the analog outputs Name PIN open-loop operation closed-loop operation AO1 22 Actual value display (CP01) 0…±400 Hz Actual value display (CP01) 0…±4000 rpm AO2 24 Apparent current 0…2•IoutN
  • 18. GB - 18 Control circuit 2.1.4.7 Connection of the relay outputs Connection of the relay outputs 262830 252729 R2 R1 Specification: U = max. 30 Vdc I = 0.01…1 A Ohmic load Output Factory setting of the relay outputs Name PIN open-loop operation closed-loop operation R1 26/28/30 Fault relay R2 25/27/29 Frequency-dependent switch Run signal
  • 19. GB - 19 Parameter Description 3. Parameter Description On delivery the KEB COMBIVERT G6 is assigned with an user menu, the customer parame- ters (CP-Parameters). These represent a selection of important parameters for the operation. Up to a maximum of 48 customer parameters can be defined from over 500 parameters. Only parameter CP00 password input is predefined and can not be modified or deleted. Depending on the unit, there are three different customer parameter menus: • for open-loop operation 00G6N1B-C000 • for ASCL operation 00G6N1B-H000 • for SCL operation 00G6N1B-J000 The menu to be used can be determined from parameter CP48 (see below). CP48 Software version Co-domain Setting Description 0.0.0.0 … F.F.F.F – Display of the software version The first two digits display the major and minor version number (e.g. 1.2.x.x => V1.2) The third digit displays the power unit software x.x.0.x Power unit open-loop 1st version x.x.1.x Power unit open-loop 2nd version x.x.2.x Power unit ASCL x.x.3.x Power unit SCL The fourth digit displays a serial number for the date code.
  • 20. KEB Antriebstechnik Austria GmbH Ritzstraße 8 • A-4614 Marchtrenk fon: +43 7243 53586-0 • fax: +43 7243 53586-21 net: www.keb.at • mail: info@keb.at KEB Antriebstechnik Herenveld 2 • B-9500 Geraadsbergen fon: +32 5443 7860 • fax: +32 5443 7898 mail: vb.belgien@keb.de KEB Power Transmission Technology (Shanghai) Co.,Ltd. No. 435 Qianpu Road, Chedun Town, Songjiang District, CHN-Shanghai 201611, P.R. China fon: +86 21 37746688 • fax: +86 21 37746600 net: www.keb.cn • mail: info@keb.cn KEB Antriebstechnik Austria GmbH Organizační složka K. Weise 1675/5 • CZ-370 04 České Budějovice fon: +420 387 699 111 • fax: +420 387 699 119 net: www.keb.cz • mail: info.keb@seznam.cz KEB Antriebstechnik GmbH Wildbacher Str. 5 • D–08289 Schneeberg fon: +49 3772 67-0 • fax: +49 3772 67-281 mail: info@keb-drive.de KEB España C/ Mitjer, Nave 8 - Pol. Ind. LA MASIA E-08798 Sant Cugat Sesgarrigues (Barcelona) fon: +34 93 897 0268 • fax: +34 93 899 2035 mail: vb.espana@keb.de Société Française KEB Z.I. de la Croix St. Nicolas • 14, rue Gustave Eiffel F-94510 LA QUEUE EN BRIE fon: +33 1 49620101 • fax: +33 1 45767495 net: www.keb.fr • mail: info@keb.fr KEB (UK) Ltd. 6 Chieftain Buisiness Park, Morris Close Park Farm, Wellingborough GB-Northants, NN8 6 XF fon: +44 1933 402220 • fax: +44 1933 400724 net: www.keb-uk.co.uk • mail: info@keb-uk.co.uk KEB Italia S.r.l. Via Newton, 2 • I-20019 Settimo Milanese (Milano) fon: +39 02 3353531 • fax: +39 02 33500790 net: www.keb.it • mail: kebitalia@keb.it KEB Japan Ltd. 15–16, 2–Chome, Takanawa Minato-ku J–Tokyo 108-0074 fon: +81 33 445-8515 • fax: +81 33 445-8215 mail: info@keb.jp KEB Korea Seoul Room 1709, 415 Missy 2000 725 Su Seo Dong, Gang Nam Gu ROK-135-757 Seoul/South Korea fon: +82 2 6253 6771 • fax: +82 2 6253 6770 mail: vb.korea@keb.de KEB RUS Ltd. Lesnaya Str. House 30, Dzerzhinsky (MO) RUS-140091 Moscow region fon: +7 495 550 8367 • fax: +7 495 632 0217 net: www.keb.ru • mail: info@keb.ru KEB Sverige Box 265 (Bergavägen 19) S-43093 Hälsö fon: +46 31 961520 • fax: +46 31 961124 mail: vb.schweden@keb.de KEB America, Inc. 5100 Valley Industrial Blvd. South USA-Shakopee, MN 55379 fon: +1 952 224-1400 • fax: +1 952 224-1499 net: www.kebamerica.com • mail: info@kebamerica.com © KEB Mat.No. 00G6NES-E000 Rev. 1D Date 03/2013 More and newest addresses at http://www.keb.de Karl E. Brinkmann GmbH Försterweg 36-38 • D-32683 Barntrup fon: +49 5263 401-0 • fax: +49 5263 401-116 net: www.keb.de • mail: info@keb.de KEB worldwide…