PERFORMANCE OF FRAMED BUILDING WITH SOFT STOREY AT
DIFFERENT LEVELS
Saumya Yadav1, Sauhardra Ojha2, Late Dr. K. Narayan3
1Assistant Professor, G.C.R.G. Group of Institutions, Lucknow, U.P., India
2Assistant Professor, Dr. RML University, Ayodhya, U.P., India
3Pro Vice Chancellor (AKTU) & Professor in Civil Engineering Department, Institute of Engineering & Technology,
Lucknow, U.P., India
---------------------------------------------------------------------***----------------------------------------------------------------------
Abstract - In high rise building or multi storey building, soft
storey construction is a typical feature because of
urbanization and the space occupancy considerations.
Reinforced concrete framed buildings with in-fills are usually
analyzed as bare frame, without considering the strength and
stiffness contributions of the in-fills. However when subjected
to a strong lateral loads, infill panels tends to interact with
bonding frame and may induce a load resistance mechanism
that is not accounted for the design. These provisions reduce
the stiffness of the lateral load resisting system and a
progressive collapse becomes unavoidable in a severe
earthquake for such buildings due to soft storey. This storey
level containing the concrete columns were unable to provide
adequate shear resistance, hence damage and collapse are
most often observed in soft storey buildings during the
earthquake. Open first storey is a typicalfeatureinthemodern
multi-storey constructions in urban India. Such features are
highly undesirable in buildings built in seismically active
areas; this has been verified in numerousexperiencesofstrong
shaking during the past earthquakes. Response spectrum
analysis is chosen for the analysis of the model since it
provides response to the applied loads and spectra conditions.
In the current study the focus is on the performance and
behavior of a structure with soft storey at different floorswith
the help of response spectrum method. For analysis purpose,
six different cases of model are studied using ETABSV.16.03. A
G+20 building with simple square plan is considered, as per IS
456:2000 and IS 1893:2002.
Key Words: Nonlinear-staticanalysis,ResponseSpectrum
analysis, Performance based assessment, Soft storey,
Stiffness, Drift index.
1. INTRODUCTION
Many urban multi-storey buildings in India today have
open first storey as an unavoidable feature. This is primarily
being adopted to accommodate parking or reception lobbies
in the first stories. The upper stories have brick infill wall
panels. The Indian seismic code classifies a soft storey as one
whose lateral stiffness is less than 70% of the storey above.
Whereas the total seismic base shear as experienced by a
building during an earthquake is dependent on its natural
period, the seismic force distribution is dependent on the
distribution of stiffness and mass along the height. In
buildings with ground soft storey, the upper storey’s being
stiff undergonesmallerinter-storeydrifts.However,theinter-
storey drift index in the ground soft storey is large. The
strength demand on the columns in the ground storey is also
large, as the shear in the first storey is more.
Soft storeys are one of the typical causes of failure of
structures during earthquakes. A soft storey is a structural
anomaly attributed to the discontinuity of stiffness along the
height of a structure. Severe structural damages suffered by
several modern buildings during recent earthquakes
illustrate the importance of avoiding sudden changes in
vertical stiffness and strength. Classically being associated
with retail spaces and parking garages, they are oftenseen in
lower stories of the building, which means when they
collapse, they can cause serious structural damage or even
lead to the collapse of the whole building.
1.1 Behavior of Soft Storey:
Many building structures having soft stories suffered
major structural damage and collapsed in the recent
earthquakes. Large open areas with less infill and exterior
walls in ground floor compared to upper floors are the cause
of damages. In such buildings, the stiffness of the lateral load
resisting systemsat those stories is quite lessthanthestories
above or below. During an earthquake, if abnormal inter-
storey drifts betweenadjacentstoriesoccur,thelateralforces
cannot be well distributed along the height of the structure.
This situation causes the lateral forces to concentrate on the
storey having large displacement. In addition, if the local
ductility demandsare not met in the designofsuchabuilding
structure for that storey and the inter-storey drifts are not
limited, a local failure mechanism or, even worse, a storey
failure mechanism, which may lead to the collapse of the
system, may be formed due to the high level of load
deformation effects.
Lateral displacement of a storey is a function of stiffness,
mass and lateral force distributed on that storey. It is also
knownthat the lateral force distribution along the height ofa
building is directly related to mass and stiffness of each
storey.If the P-delta effectisconsideredtobethemainreason
for the dynamic collapse of building structures during
earthquakes, accurately determined lateral displacements
calculated in the elastic design process may provide very
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 06 Issue: 10 | Oct 2019 www.irjet.net p-ISSN: 2395-0072
© 2019, IRJET | Impact Factor value: 7.34 | ISO 9001:2008 Certified Journal | Page 124
important information about the structural behavior of the
system.
Many RC buildings constructed in recent times have a
special feature – the ground storey is left open for the
purpose of parking, i.e., columns in the ground storey do not
have any partition walls (of either masonry or RC) between
them. Such buildings are often called open ground storey
buildings or buildings on stilts. An open ground storey
building, having only columns in the ground storey and both
partition walls and columns in the upper storeys, have two
distinct characteristics, namely:
(a) It is relatively flexible in the ground storey, i.e., the
relative horizontal displacement it undergoes inthe ground
storey is much larger than what each of the storeys above it
does. This flexible ground storey is also called soft storey.
(b) It is relatively weak in ground storey, i.e., the total
horizontal earthquake force it can carry in the ground storey
is significantly smaller than what eachofthe storeys above it
can carry. Thus, the open ground storey may also be a weak
storey.
Often, openground storey buildingsare called softstorey
buildings, even though their ground storey may be soft and
weak. Generally, the soft or weak storey usually exists at the
ground storey level, but it could be at any other storey level
too.
Figure 1: Upper storeys of open ground storey building
move together as a single block – such buildings are like
inverted pendulums.
The presence of walls in upper storeys makes them much
stiffer than the open ground storey. Thus, the upper storeys
move almost together as a single block, and most of the
horizontal displacement of the building occurs in the soft
ground storey itself. In common language, this type of
buildings can be explained as a building on chopsticks. Thus,
suchbuildingsswingback-and-forthlikeinvertedpendulums
during earthquake shaking, and the columns in the open
ground storey are severely stressed. If the columns are weak
(do not have the required strength to resist these high
stresses) or if they do not have adequate ductility, they may
be severely damaged which may even lead to collapse of the
building. Due to this,such inverted pendulumlikebehavioris
also seen in the cases where soft storey is created at above
floors. The storeys below the soft storey and above it act
individually like a single block and the upper portion moves
to and fro during earthquake (oscillating like inverted
pendulum).
1.2 Scope & Objective
The strength and stiffness of infill walls in infill frame
buildings are ignored in the structural modeling in
conventional design practice. The design in such cases will
generally be conservative in the case of fully infill framed
building. But things will be different for an open ground
storey framed building. Open ground storey building is
slightly stiffer than the bare frame, has larger drift especially
in the ground storey, and fails due to soft storey mechanism
at the ground floor. The scope ofthe study is to find the effect
of masonry infill panel on the response of RC frames
subjected to seismicaction byconductingresponsespectrum
analysis for RC frame with infill wall at varying arrangement
using ETABS 2015.
The main objectives of the study are:
 To study the behaviour of reinforced concrete
framed multi-storeyed building with soft storey
at different floor levels.
 To study the critical condition generated due to
soft storey conditions.
 To compare various parameters such as
displacement, stiffness, inter-storey drift index
and base shear.
 To find the minimum damage level of high rise
buildings with soft storeys
2. Response Spectrum Analysis
There are three analysis methods forthe seismic analysis
of the structure, pushover analysis, timehistory analysisand
response spectrum analysis. Response spectrum analysis is
chosen for the analysis of the model since it provides
response to the applied loads and spectra conditions. One of
the major objectives of this paper is to analyze the effect of
soft-storey at various arrangements andthismethodhelpsin
studying that comparison.
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 06 Issue: 10 | Oct 2019 www.irjet.net p-ISSN: 2395-0072
© 2019, IRJET | Impact Factor value: 7.34 | ISO 9001:2008 Certified Journal | Page 125
In the response spectrum analysis procedure, each of the
model’s modes is considered to be an independent SDOF
system. The maximum responses for each mode are
calculated independently. These modal responses are then
combined to obtain the model’s overall response to the
applied spectra. The response spectrum method enjoyswide
acceptance as anaccuratemethodforpredictingtheresponse
of any structural model to any arbitrary base excitation,
particularly earthquakes. It is easier, faster and more
accurate than the static procedure so there really is not any
reason to use the static procedure. Response spectrum
analysis isa linear-dynamicstatisticalanalysismethodwhich
measures the contribution from each natural mode of
vibration to indicatethelikely maximum seismic responseof
an essentially elastic structure. It is a procedure for
computing the statisticalmaximumresponseofastructureto
a base excitation. Each of the vibration modes that are
considered may be assumed to respond independently as a
single degree-of-freedom system. It is useful for design
decision-making because it relates structural type-selection
to dynamic performance.
The responsespectrumanalysisprocedureisbasedonthe
assumption that the dynamic response of a structural model
can be approximated as a summation of the responses of the
independent dynamic modes of the model. The usual
application of this method is in seismic analysis. With
response spectrum method, it is possible to predict the
maximum response forany single degree-of-freedom(SDOF)
system. By “any SDOF system”, it is meant a SDOF system
with any natural frequency. “Maximum response” means the
maximum deflections.
In the response spectrum analysis procedure, each of the
model’s modes is considered to be an independent SDOF
system. The maximum responses for each mode are
calculated independently. These modal responses are then
combined to obtain the model’s overall response to the
applied spectra. The response spectrum method enjoyswide
acceptance as anaccuratemethodforpredictingtheresponse
of any structural model to any arbitrary base excitation,
particularly earthquakes. Building codes require a dynamics
based procedure for some structures. This method satisfies
this dynamic requirement. It is easier, faster and more
accurate than the static procedure so there really is not any
reason to use the static procedure.
3. Structural & Loading Details
Table 1: Modeling and Loading of Structure
1 Plan Dimensions 30 x 30 m
2 Number of story G+20
2 Floor to floor height 3.6m
4 Slab thickness 150mm
5 Size of beam 450mm x 500mm
6 Size of column 600mm x 600mm
7 Thickness of infill wall 230mm
8 Thickness of slab 150mm, M40
9 Zone and zone factor III, 0.16
10 Importance factor 1.5
11 Response factor (R) 5
12 Grade of concrete and
rebar in beam
M35, Fe500
13 Grade of concrete (Slab) M35
14 Grade of concrete and
rebar in column
M40, Fe415
15 Grade of shear wall M40
16 Live load and floor finish
load
3kN/ m2and
1kN/m2
kN/
17 Top floor load 2kN/ m2
18 Masonry load Half brick wall, 7.2
kN/m m2
Equivalent Diagonal Strut Method is used for modelling the
infill wall. In this method the infill wall is idealized as
diagonal strut and the frame is modelled as beam or truss
element. Frame analysis techniques are used for the elastic
analysis. The idealization is based on the assumption that
there is no bond between frame and infill.
Figure 2: Plan of the bulding
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 06 Issue: 10 | Oct 2019 www.irjet.net p-ISSN: 2395-0072
© 2019, IRJET | Impact Factor value: 7.34 | ISO 9001:2008 Certified Journal | Page 126
Figure 3: 3D layout of the structure
IS 1893 (Part 1): 2016 Criteria for Earthquake Resistant
Design of Structures deals with assessment of seismic loads
on various structures and earthquake resistant design of
buildings.
As per IS 1893 (Part 1):2016, whenearthquakeforcesare
considered on a structure in the limit state design of
reinforced and prestressed concrete structures, 13 load
combinations shall be accounted for.
As per IS 1893:2016, for various loading classes as
specified in IS 875 (Part 2), the seismic force shall be
calculated for the full dead load plus the percentage of
imposed load as given in below table.
Table 2: Live Load Reduction Clause as per IS 1893:2016
Imposed Uniformity
Distributed Floor Loads
( kN/ m² )
Percentage of ImposedLoad
Up to and including 3.0 25
Above 3.0 50
4. Behavior of the cases to be analyzed:
Six different cases are taken and analysed: Full Masonry
Structure, Soft Storey at Ground Floor, Soft Storey at 5th
Floor, SoftStorey at 10th Floor, SoftStorey at 15thFloor, Soft
Storey at 20th Floor. Symmetrical constructions in bothplan
and height show a better resistance during an earthquake
than those that do not have this symmetry. Since the
presence of a soft storey which has less rigidity than other
storeys spoils the perpendicular symmetry of the
construction, and if this fact was not taken into
consideration, it causes the constructiontobeaffected bythe
quake because the columns in this part are forced by the
quake more than the ones in the other parts of the building.
Studies conducted suggest that walls increase the rigidity at
a certain degree in the construction. The soft storey
configuration is possible in by different arrangement in the
building.
(a) (b)
(c) (d)
(e) (f)
Figure 4: Behavior of structure with soft storey at different
floor during earthquake
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 06 Issue: 10 | Oct 2019 www.irjet.net p-ISSN: 2395-0072
© 2019, IRJET | Impact Factor value: 7.34 | ISO 9001:2008 Certified Journal | Page 127
Soft storey configuration in structures is a type of
construction where any one storey of the building is more
flexible (less stiff) when compared with other floors. This
may be located at the bottom, or at any intermediate points,
where the floorabove or below it may bestiffer compared to
itself. This accounts to be a weak element in the perspective
of seismic forces. This weakness may be a sharp variation in
the stiffness, drift index orin the strength parameters.These
variations result in the poor distribution of masses
throughout the floor, which is undesirable.
5. RESULTS
5.1 BASE SHEAR
Base reactions are assessed for all the cases and further
calculations are doneaccordingly.Baseshearisrevieweddue
to all the modes reported in the Response Spectrum Base
Reaction Table. If the dynamic base shear reported is more
than 85% of the static base shear, no further action is
required. However, if dynamic base shear is less than 85% of
the static base shear, then the scale factor should beadjusted
such that the response spectrum base shear matches 85% of
the static base shear.
Base shearisanestimateofthemaximumexpectedlateral
force that will occur due to seismicgroundmotionatthebase
of a structure. It is a very important parameter for
earthquake resistant design ofbuildings.Amongallthecases,
base shear is highest for full masonry structure and least for
soft storey at ground level. This indicates that the case 2, i.e.
soft-storey at ground level is most vulnerable during
earthquake. The whole structure is critical under this case.
Full masonry structure is the most reliable one.
Figure 5: Bar graph showing variations in base shear of
all the cases on Y-axis
5.2 INTER-STOREY DRIFT INDEX
Storey drift is the drift of one level of a multi- storey
building relative to the level below. Lateral drift and inter-
storey drift are commonly used damage parameter in
structural analysis. In this study, lateral drift of the 3D
building frame was analysed for earthquake load coming
from long direction.
Inter-storey drift index was also evaluated and tabulated
which is given by
Where, VUi – VUi-1 = Relative displacement between
successive storey.
hi = Storey height.
It is observed that for all cases there is a sudden
increment in drift index at soft storey level, which is due to
absence of masonry infill. The lateralload is more effectiveat
that floor. The drift index value of soft storey at ground floor
of the building is more. The driftindexvalueisverylesswhen
soft storey is at top of the building.
5.3 STOREY STIFFNESS
Stiffness is the rigidity of an object i.e., the extenttowhich
it resists deformation in response to an applied force. As per
IS 1893:2016, soft storey is one in which the lateral stiffness
is less than that in the storey above. As per IS 1893:2002,soft
storey is one in which the lateral stiffness is less than 70
percent of that in the storey above or less than 80 per cent of
the average lateral stiffness of the three storeys above.
At the soft-storey level there is a decrement in the storey
stiffness. The stiffness decreases as we move upwards,
meaning that as the storey height increases, storey stiffness
decreases. After the decrement point the previous curve
proceeds. This means that the upper portion haslesservalue
of storey stiffness than the lower portion.
6. CONCLUSIONS
RC frame buildings with soft storey are known to perform
poorly during in strong earthquake shaking. In this project,
the seismic vulnerability of buildings with soft storey at
different floor levels is shown through an example building.
Tall building of G+20 storeys is provided with soft storey at
different floor levels to be analysed for the load as per IS
1893:2016, using software package ETABS 2015. The
building islocated in seismic zoneIII. The resultsmayhelpto
the future construction of soft storey buildings. From the
result it is concluded that,
 The displacement ofstorey increasesatsoftstorey
level due to increase in application of dynamic
forces on it. The presence of infill wall can affect
the seismic behaviour of frame structure to large
extent, and the infill wall increases the stability of
the building.
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 06 Issue: 10 | Oct 2019 www.irjet.net p-ISSN: 2395-0072
© 2019, IRJET | Impact Factor value: 7.34 | ISO 9001:2008 Certified Journal | Page 128
 There is a drop in the storey stiffness at softstorey
level in all cases. From this more care is need
design the columns in the soft storey. Infill panels
increases the stiffness of the structure. Hence
behaviour of building varies with the change in
infill arrangements.
 The buildings with soft storeys resist smaller
forces as compared to the stiff structures. The
base shear at different floor levels is lesser for the
buildings with softstoreys as compared tothestiff
buildings. The base shear in the building with no
soft storey is found maximum i.e. 25482.2 kN.
 On comparing the storey response of the cases, it
is observed that the storey drift index in case of
buildings with soft storey is very large as
compared to a stiff building. This high relative
drift index in the building lead to a largeamount of
undesirable additional bending moments in
columns which leads to the failure ofthe structure
as a whole. In case of an open first storey frame
structure, the storey drift index is very large than
in the upper storeys i.e. 0.002068, which may
cause the collapse of structure during strong
earthquakeshaking.
 The soft storey columns require more percentage
of reinforcement.
 It is advisable to provide soft storey at higher
levels. The presence of walls in upper storey
makes the much stiffer than open ground storey.
Hence, the upper storey movealmosttogetherasa
single block and most of the horizontal
displacement of the building occurs in the soft
ground storey itself such building movestoandfro
when earthquake occurs. Thus it is clear that
building with only column in the ground storey
has poor performance during earthquake as
compared to building with both wall and column
in the ground storey.
Earthquake vulnerability of buildings with open ground
floors is well known around the world. For a building that is
not provided any lateral load resistance component such as
shear wall or bracing, the strength is consider very weak and
easily fail during earthquake. Other possible schemes to
achieve the above objective are:
(i) Provision of stiffer columns in the first storey in case of
ground soft storey, and
(ii) Provision of a concrete service core in the building.
The former is effective only in reducing the lateral drift
demand on the first storey columns. However the latter is
effective in reducing the driftas wellasthestrengthdemands
on the soft storey columns
REFERENCES
[1] A. Madan, A. M. Reinhorn, J. B. Mander, R. E. Valles,
“Modelling of Masonry Infill Panels for Structural
Analysis”, Journal of Structural Engineering, October
1997.
[2] Abhishek Arora, “Alternative Approach to Soft Storey in
Seismic Analysis of R.C.C Building Structures”, April
2015.
[3] Agarwal, P. and Shrikhande, M., “Earthquake Resistant
Design of Structures”, PHI Publication, 2004.
[4] Bhakti Narayan Harne, R. R. Shinde, “Seismic
Performance of Multi-Storied RC Building with Soft
Storey”, International Journal of Emerging Technology
and Advanced Engineering, Volume 5/ pp.116-122/
2015.
[5] Bureau of Indian Standards, “Criteria for Earthquake
Resistant Design Of Structures” IS: 1893 (Part I): 2016
(Sixth Revision).
[6] Bureau of Indian Standards, “Code Of Practice For
Design Loads (Other Than Earthquake) For Buildings
And Structures: Special Loads And Combinations” IS:
875 ( Part 5 ) – 1997 (Second Revision).
[7] Bureau of Indian Standards, “Plain and Reinforced
Concrete – Code of Practice” IS: 456-2000 (Fourth
Revision).
[8] Bureau of Indian Standards, “Earthquake Resistant
Design And Construction Of Buildings —Code Of
Practice” IS: 4326-1993 (Second Revision).
[9] C. V. R. Murty, “How do Brick Masonry houses behave
during Earthquakes?”, Building Materials and
Technology Promotion Council, New Delhi.
[10] C. V. R. Murty, “Why are Open Ground Storey Buildings
vulnerable in Earthquake?”, Indian Institute of
Technology, Kanpur.

More Related Content

PDF
12 fundamentals for_seismic_design_of_rcc_buildings_by_prof_arya
PDF
ANALYSIS OF SOFT STOREY FOR MULTI STORYED BUILDING IN ZONE-4
PDF
Ac34176185
PDF
LATERAL LOAD ANALYSIS OF SOFT STORY BUILDING AND IMPORTANCE OF MODELING MASON...
PDF
Analysis of Building with Soft Storey during Earthquake
PDF
Seismic performance of a rc frame with soft storey criteria
PDF
Seismic Drift Consideration in soft storied RCC buildings: A Critical Review
PDF
IRJET- Post Peak Response of Reinforced Concrete Frames with and without in F...
12 fundamentals for_seismic_design_of_rcc_buildings_by_prof_arya
ANALYSIS OF SOFT STOREY FOR MULTI STORYED BUILDING IN ZONE-4
Ac34176185
LATERAL LOAD ANALYSIS OF SOFT STORY BUILDING AND IMPORTANCE OF MODELING MASON...
Analysis of Building with Soft Storey during Earthquake
Seismic performance of a rc frame with soft storey criteria
Seismic Drift Consideration in soft storied RCC buildings: A Critical Review
IRJET- Post Peak Response of Reinforced Concrete Frames with and without in F...

What's hot (20)

PDF
EFFECT OF SHEAR WALL AREA ON SEISMIC BEHAVIOR OF MULTI STORIED BUILDINGS WITH...
PDF
IRJET- Analysis of Various Effects on Multistory Building (G+27) by Staad Pro...
PDF
STUDY ON SEISMIC EFFECT OF HIGH RISE BUILDING SHEAR WALL/WALL WITHOUT SHEAR WALL
PDF
IRJET- Comparative Analysis of Square Shape RC Frame by Replacing Masonry fro...
PDF
IRJET- Seismic Analysis of Multistoried Building with and without Shear Wall ...
PDF
IRJET-Effect of Shear Wall on Seismic Performance of RC Open Ground Storey Fr...
PDF
Analysis and Capacity Based Earthquake Resistance Design of Multy Bay Multy S...
PPTX
Earth resistant design philosophy
PDF
Earthquake load as per nbc 105 and is 1893
PDF
Study of lateral load resisting systems of variable heights in all soil types...
PDF
Special moment frames aci 318 - اطارات مقاومة للعزوم
DOCX
shear wall shear design
PDF
Shear walls and re entrant corners
PDF
Behavior of rc structure under earthquake loading
PPTX
Earthquake Resistance Structures
PDF
IRJET- Comparative Study of Flat Slab and Conventional Slab Structure wit...
PDF
IRJET- Seismic Linear Analysis of Low Rise Open Ground Storey Buildings
PDF
Performance of shear wall building during seismic excitations
PDF
Lec05 STRUCTURE SYSTEMS to resist EARTHQUAKE (Earthquake Engineering هندسة ال...
PDF
Lateral Load Analysis of Shear Wall and Concrete Braced Multi-Storeyed R.C Fr...
EFFECT OF SHEAR WALL AREA ON SEISMIC BEHAVIOR OF MULTI STORIED BUILDINGS WITH...
IRJET- Analysis of Various Effects on Multistory Building (G+27) by Staad Pro...
STUDY ON SEISMIC EFFECT OF HIGH RISE BUILDING SHEAR WALL/WALL WITHOUT SHEAR WALL
IRJET- Comparative Analysis of Square Shape RC Frame by Replacing Masonry fro...
IRJET- Seismic Analysis of Multistoried Building with and without Shear Wall ...
IRJET-Effect of Shear Wall on Seismic Performance of RC Open Ground Storey Fr...
Analysis and Capacity Based Earthquake Resistance Design of Multy Bay Multy S...
Earth resistant design philosophy
Earthquake load as per nbc 105 and is 1893
Study of lateral load resisting systems of variable heights in all soil types...
Special moment frames aci 318 - اطارات مقاومة للعزوم
shear wall shear design
Shear walls and re entrant corners
Behavior of rc structure under earthquake loading
Earthquake Resistance Structures
IRJET- Comparative Study of Flat Slab and Conventional Slab Structure wit...
IRJET- Seismic Linear Analysis of Low Rise Open Ground Storey Buildings
Performance of shear wall building during seismic excitations
Lec05 STRUCTURE SYSTEMS to resist EARTHQUAKE (Earthquake Engineering هندسة ال...
Lateral Load Analysis of Shear Wall and Concrete Braced Multi-Storeyed R.C Fr...
Ad

Similar to IRJET- Performance of Framed Building with Soft Storey at Different Levels (20)

PDF
IRJET- A Review on Analysis of Soft Story at Intermediate Levels in a Multi-S...
PDF
IRJET- Seismic Analysis of Multistory Building with Floating Column : A R...
PDF
Seismic Response of Multi storey Flat Slab Building with and without Shear Wall
PDF
IRJET- Seismic Analysis of Multi-Storey Building with and without Floating Co...
PDF
Review on seismic performance of multi storied rc building with soft storey
PDF
Dynamic Analysis of Multi-Storeyed Frame-Shear Wall Building Considering SSI
PDF
A Review on Analysis of a Tall Structure with Shear Panel and Floating Columns
PDF
IRJET- Research on Seismic Analysis of Multistorey Building for Soft Ground
PDF
IRJET- A Review on Seismic Analysis and Sustainability of Multi Storey Struct...
PDF
Descriptive study of pushover analysis in rcc structures of rigid joint
PDF
IRJET- A Review on R.C.C. Structure with Fully, Partially and without Infille...
PDF
IRJET- Seismic Analysis of Buildings with Shear Wall having Horizontal Ir...
PDF
Comparison of Seismic Analysis of Multistorey Building Resting on Sloped Grou...
PDF
Significance of shear wall in flat slab multi storied building - A Review
PDF
IRJET - A Review on Seismic Behaviour of Floating Column and Transfer Beam
PDF
IRJET- Analytical Design for Optimization of Shear Wall for Flat Slab
PDF
IRJET- Seismic Analysis of Multistorey Buildings with Vertical Irregularities...
PDF
A REVIEW PAPER ON ANALYSIS AND DESIGN OF MULTISTORY BUILDING WITH DIFFERENT S...
PDF
IRJET- Behavior and Comparison of Multistory Building of Shear Wall with and ...
PDF
IRJET- A Research on Comparing the Effect of Seismic Waves on Multistoried Bu...
IRJET- A Review on Analysis of Soft Story at Intermediate Levels in a Multi-S...
IRJET- Seismic Analysis of Multistory Building with Floating Column : A R...
Seismic Response of Multi storey Flat Slab Building with and without Shear Wall
IRJET- Seismic Analysis of Multi-Storey Building with and without Floating Co...
Review on seismic performance of multi storied rc building with soft storey
Dynamic Analysis of Multi-Storeyed Frame-Shear Wall Building Considering SSI
A Review on Analysis of a Tall Structure with Shear Panel and Floating Columns
IRJET- Research on Seismic Analysis of Multistorey Building for Soft Ground
IRJET- A Review on Seismic Analysis and Sustainability of Multi Storey Struct...
Descriptive study of pushover analysis in rcc structures of rigid joint
IRJET- A Review on R.C.C. Structure with Fully, Partially and without Infille...
IRJET- Seismic Analysis of Buildings with Shear Wall having Horizontal Ir...
Comparison of Seismic Analysis of Multistorey Building Resting on Sloped Grou...
Significance of shear wall in flat slab multi storied building - A Review
IRJET - A Review on Seismic Behaviour of Floating Column and Transfer Beam
IRJET- Analytical Design for Optimization of Shear Wall for Flat Slab
IRJET- Seismic Analysis of Multistorey Buildings with Vertical Irregularities...
A REVIEW PAPER ON ANALYSIS AND DESIGN OF MULTISTORY BUILDING WITH DIFFERENT S...
IRJET- Behavior and Comparison of Multistory Building of Shear Wall with and ...
IRJET- A Research on Comparing the Effect of Seismic Waves on Multistoried Bu...
Ad

More from IRJET Journal (20)

PDF
Enhanced heart disease prediction using SKNDGR ensemble Machine Learning Model
PDF
Utilizing Biomedical Waste for Sustainable Brick Manufacturing: A Novel Appro...
PDF
Kiona – A Smart Society Automation Project
PDF
DESIGN AND DEVELOPMENT OF BATTERY THERMAL MANAGEMENT SYSTEM USING PHASE CHANG...
PDF
Invest in Innovation: Empowering Ideas through Blockchain Based Crowdfunding
PDF
SPACE WATCH YOUR REAL-TIME SPACE INFORMATION HUB
PDF
A Review on Influence of Fluid Viscous Damper on The Behaviour of Multi-store...
PDF
Wireless Arduino Control via Mobile: Eliminating the Need for a Dedicated Wir...
PDF
Explainable AI(XAI) using LIME and Disease Detection in Mango Leaf by Transfe...
PDF
BRAIN TUMOUR DETECTION AND CLASSIFICATION
PDF
The Project Manager as an ambassador of the contract. The case of NEC4 ECC co...
PDF
"Enhanced Heat Transfer Performance in Shell and Tube Heat Exchangers: A CFD ...
PDF
Advancements in CFD Analysis of Shell and Tube Heat Exchangers with Nanofluid...
PDF
Breast Cancer Detection using Computer Vision
PDF
Auto-Charging E-Vehicle with its battery Management.
PDF
Analysis of high energy charge particle in the Heliosphere
PDF
A Novel System for Recommending Agricultural Crops Using Machine Learning App...
PDF
Auto-Charging E-Vehicle with its battery Management.
PDF
Analysis of high energy charge particle in the Heliosphere
PDF
Wireless Arduino Control via Mobile: Eliminating the Need for a Dedicated Wir...
Enhanced heart disease prediction using SKNDGR ensemble Machine Learning Model
Utilizing Biomedical Waste for Sustainable Brick Manufacturing: A Novel Appro...
Kiona – A Smart Society Automation Project
DESIGN AND DEVELOPMENT OF BATTERY THERMAL MANAGEMENT SYSTEM USING PHASE CHANG...
Invest in Innovation: Empowering Ideas through Blockchain Based Crowdfunding
SPACE WATCH YOUR REAL-TIME SPACE INFORMATION HUB
A Review on Influence of Fluid Viscous Damper on The Behaviour of Multi-store...
Wireless Arduino Control via Mobile: Eliminating the Need for a Dedicated Wir...
Explainable AI(XAI) using LIME and Disease Detection in Mango Leaf by Transfe...
BRAIN TUMOUR DETECTION AND CLASSIFICATION
The Project Manager as an ambassador of the contract. The case of NEC4 ECC co...
"Enhanced Heat Transfer Performance in Shell and Tube Heat Exchangers: A CFD ...
Advancements in CFD Analysis of Shell and Tube Heat Exchangers with Nanofluid...
Breast Cancer Detection using Computer Vision
Auto-Charging E-Vehicle with its battery Management.
Analysis of high energy charge particle in the Heliosphere
A Novel System for Recommending Agricultural Crops Using Machine Learning App...
Auto-Charging E-Vehicle with its battery Management.
Analysis of high energy charge particle in the Heliosphere
Wireless Arduino Control via Mobile: Eliminating the Need for a Dedicated Wir...

Recently uploaded (20)

PPTX
CYBER-CRIMES AND SECURITY A guide to understanding
PDF
Well-logging-methods_new................
PDF
Human-AI Collaboration: Balancing Agentic AI and Autonomy in Hybrid Systems
PDF
III.4.1.2_The_Space_Environment.p pdffdf
DOCX
573137875-Attendance-Management-System-original
PPT
Project quality management in manufacturing
PDF
The CXO Playbook 2025 – Future-Ready Strategies for C-Suite Leaders Cerebrai...
PPTX
Construction Project Organization Group 2.pptx
PPTX
Safety Seminar civil to be ensured for safe working.
PPTX
Infosys Presentation by1.Riyan Bagwan 2.Samadhan Naiknavare 3.Gaurav Shinde 4...
PDF
keyrequirementskkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk
PPTX
M Tech Sem 1 Civil Engineering Environmental Sciences.pptx
PDF
737-MAX_SRG.pdf student reference guides
PPTX
Artificial Intelligence
PDF
Artificial Superintelligence (ASI) Alliance Vision Paper.pdf
PPT
Total quality management ppt for engineering students
PPTX
Foundation to blockchain - A guide to Blockchain Tech
PDF
BMEC211 - INTRODUCTION TO MECHATRONICS-1.pdf
PPTX
Fundamentals of Mechanical Engineering.pptx
PPT
Introduction, IoT Design Methodology, Case Study on IoT System for Weather Mo...
CYBER-CRIMES AND SECURITY A guide to understanding
Well-logging-methods_new................
Human-AI Collaboration: Balancing Agentic AI and Autonomy in Hybrid Systems
III.4.1.2_The_Space_Environment.p pdffdf
573137875-Attendance-Management-System-original
Project quality management in manufacturing
The CXO Playbook 2025 – Future-Ready Strategies for C-Suite Leaders Cerebrai...
Construction Project Organization Group 2.pptx
Safety Seminar civil to be ensured for safe working.
Infosys Presentation by1.Riyan Bagwan 2.Samadhan Naiknavare 3.Gaurav Shinde 4...
keyrequirementskkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkkk
M Tech Sem 1 Civil Engineering Environmental Sciences.pptx
737-MAX_SRG.pdf student reference guides
Artificial Intelligence
Artificial Superintelligence (ASI) Alliance Vision Paper.pdf
Total quality management ppt for engineering students
Foundation to blockchain - A guide to Blockchain Tech
BMEC211 - INTRODUCTION TO MECHATRONICS-1.pdf
Fundamentals of Mechanical Engineering.pptx
Introduction, IoT Design Methodology, Case Study on IoT System for Weather Mo...

IRJET- Performance of Framed Building with Soft Storey at Different Levels

  • 1. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 10 | Oct 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.34 | ISO 9001:2008 Certified Journal | Page 123 PERFORMANCE OF FRAMED BUILDING WITH SOFT STOREY AT DIFFERENT LEVELS Saumya Yadav1, Sauhardra Ojha2, Late Dr. K. Narayan3 1Assistant Professor, G.C.R.G. Group of Institutions, Lucknow, U.P., India 2Assistant Professor, Dr. RML University, Ayodhya, U.P., India 3Pro Vice Chancellor (AKTU) & Professor in Civil Engineering Department, Institute of Engineering & Technology, Lucknow, U.P., India ---------------------------------------------------------------------***---------------------------------------------------------------------- Abstract - In high rise building or multi storey building, soft storey construction is a typical feature because of urbanization and the space occupancy considerations. Reinforced concrete framed buildings with in-fills are usually analyzed as bare frame, without considering the strength and stiffness contributions of the in-fills. However when subjected to a strong lateral loads, infill panels tends to interact with bonding frame and may induce a load resistance mechanism that is not accounted for the design. These provisions reduce the stiffness of the lateral load resisting system and a progressive collapse becomes unavoidable in a severe earthquake for such buildings due to soft storey. This storey level containing the concrete columns were unable to provide adequate shear resistance, hence damage and collapse are most often observed in soft storey buildings during the earthquake. Open first storey is a typicalfeatureinthemodern multi-storey constructions in urban India. Such features are highly undesirable in buildings built in seismically active areas; this has been verified in numerousexperiencesofstrong shaking during the past earthquakes. Response spectrum analysis is chosen for the analysis of the model since it provides response to the applied loads and spectra conditions. In the current study the focus is on the performance and behavior of a structure with soft storey at different floorswith the help of response spectrum method. For analysis purpose, six different cases of model are studied using ETABSV.16.03. A G+20 building with simple square plan is considered, as per IS 456:2000 and IS 1893:2002. Key Words: Nonlinear-staticanalysis,ResponseSpectrum analysis, Performance based assessment, Soft storey, Stiffness, Drift index. 1. INTRODUCTION Many urban multi-storey buildings in India today have open first storey as an unavoidable feature. This is primarily being adopted to accommodate parking or reception lobbies in the first stories. The upper stories have brick infill wall panels. The Indian seismic code classifies a soft storey as one whose lateral stiffness is less than 70% of the storey above. Whereas the total seismic base shear as experienced by a building during an earthquake is dependent on its natural period, the seismic force distribution is dependent on the distribution of stiffness and mass along the height. In buildings with ground soft storey, the upper storey’s being stiff undergonesmallerinter-storeydrifts.However,theinter- storey drift index in the ground soft storey is large. The strength demand on the columns in the ground storey is also large, as the shear in the first storey is more. Soft storeys are one of the typical causes of failure of structures during earthquakes. A soft storey is a structural anomaly attributed to the discontinuity of stiffness along the height of a structure. Severe structural damages suffered by several modern buildings during recent earthquakes illustrate the importance of avoiding sudden changes in vertical stiffness and strength. Classically being associated with retail spaces and parking garages, they are oftenseen in lower stories of the building, which means when they collapse, they can cause serious structural damage or even lead to the collapse of the whole building. 1.1 Behavior of Soft Storey: Many building structures having soft stories suffered major structural damage and collapsed in the recent earthquakes. Large open areas with less infill and exterior walls in ground floor compared to upper floors are the cause of damages. In such buildings, the stiffness of the lateral load resisting systemsat those stories is quite lessthanthestories above or below. During an earthquake, if abnormal inter- storey drifts betweenadjacentstoriesoccur,thelateralforces cannot be well distributed along the height of the structure. This situation causes the lateral forces to concentrate on the storey having large displacement. In addition, if the local ductility demandsare not met in the designofsuchabuilding structure for that storey and the inter-storey drifts are not limited, a local failure mechanism or, even worse, a storey failure mechanism, which may lead to the collapse of the system, may be formed due to the high level of load deformation effects. Lateral displacement of a storey is a function of stiffness, mass and lateral force distributed on that storey. It is also knownthat the lateral force distribution along the height ofa building is directly related to mass and stiffness of each storey.If the P-delta effectisconsideredtobethemainreason for the dynamic collapse of building structures during earthquakes, accurately determined lateral displacements calculated in the elastic design process may provide very
  • 2. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 10 | Oct 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.34 | ISO 9001:2008 Certified Journal | Page 124 important information about the structural behavior of the system. Many RC buildings constructed in recent times have a special feature – the ground storey is left open for the purpose of parking, i.e., columns in the ground storey do not have any partition walls (of either masonry or RC) between them. Such buildings are often called open ground storey buildings or buildings on stilts. An open ground storey building, having only columns in the ground storey and both partition walls and columns in the upper storeys, have two distinct characteristics, namely: (a) It is relatively flexible in the ground storey, i.e., the relative horizontal displacement it undergoes inthe ground storey is much larger than what each of the storeys above it does. This flexible ground storey is also called soft storey. (b) It is relatively weak in ground storey, i.e., the total horizontal earthquake force it can carry in the ground storey is significantly smaller than what eachofthe storeys above it can carry. Thus, the open ground storey may also be a weak storey. Often, openground storey buildingsare called softstorey buildings, even though their ground storey may be soft and weak. Generally, the soft or weak storey usually exists at the ground storey level, but it could be at any other storey level too. Figure 1: Upper storeys of open ground storey building move together as a single block – such buildings are like inverted pendulums. The presence of walls in upper storeys makes them much stiffer than the open ground storey. Thus, the upper storeys move almost together as a single block, and most of the horizontal displacement of the building occurs in the soft ground storey itself. In common language, this type of buildings can be explained as a building on chopsticks. Thus, suchbuildingsswingback-and-forthlikeinvertedpendulums during earthquake shaking, and the columns in the open ground storey are severely stressed. If the columns are weak (do not have the required strength to resist these high stresses) or if they do not have adequate ductility, they may be severely damaged which may even lead to collapse of the building. Due to this,such inverted pendulumlikebehavioris also seen in the cases where soft storey is created at above floors. The storeys below the soft storey and above it act individually like a single block and the upper portion moves to and fro during earthquake (oscillating like inverted pendulum). 1.2 Scope & Objective The strength and stiffness of infill walls in infill frame buildings are ignored in the structural modeling in conventional design practice. The design in such cases will generally be conservative in the case of fully infill framed building. But things will be different for an open ground storey framed building. Open ground storey building is slightly stiffer than the bare frame, has larger drift especially in the ground storey, and fails due to soft storey mechanism at the ground floor. The scope ofthe study is to find the effect of masonry infill panel on the response of RC frames subjected to seismicaction byconductingresponsespectrum analysis for RC frame with infill wall at varying arrangement using ETABS 2015. The main objectives of the study are:  To study the behaviour of reinforced concrete framed multi-storeyed building with soft storey at different floor levels.  To study the critical condition generated due to soft storey conditions.  To compare various parameters such as displacement, stiffness, inter-storey drift index and base shear.  To find the minimum damage level of high rise buildings with soft storeys 2. Response Spectrum Analysis There are three analysis methods forthe seismic analysis of the structure, pushover analysis, timehistory analysisand response spectrum analysis. Response spectrum analysis is chosen for the analysis of the model since it provides response to the applied loads and spectra conditions. One of the major objectives of this paper is to analyze the effect of soft-storey at various arrangements andthismethodhelpsin studying that comparison.
  • 3. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 10 | Oct 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.34 | ISO 9001:2008 Certified Journal | Page 125 In the response spectrum analysis procedure, each of the model’s modes is considered to be an independent SDOF system. The maximum responses for each mode are calculated independently. These modal responses are then combined to obtain the model’s overall response to the applied spectra. The response spectrum method enjoyswide acceptance as anaccuratemethodforpredictingtheresponse of any structural model to any arbitrary base excitation, particularly earthquakes. It is easier, faster and more accurate than the static procedure so there really is not any reason to use the static procedure. Response spectrum analysis isa linear-dynamicstatisticalanalysismethodwhich measures the contribution from each natural mode of vibration to indicatethelikely maximum seismic responseof an essentially elastic structure. It is a procedure for computing the statisticalmaximumresponseofastructureto a base excitation. Each of the vibration modes that are considered may be assumed to respond independently as a single degree-of-freedom system. It is useful for design decision-making because it relates structural type-selection to dynamic performance. The responsespectrumanalysisprocedureisbasedonthe assumption that the dynamic response of a structural model can be approximated as a summation of the responses of the independent dynamic modes of the model. The usual application of this method is in seismic analysis. With response spectrum method, it is possible to predict the maximum response forany single degree-of-freedom(SDOF) system. By “any SDOF system”, it is meant a SDOF system with any natural frequency. “Maximum response” means the maximum deflections. In the response spectrum analysis procedure, each of the model’s modes is considered to be an independent SDOF system. The maximum responses for each mode are calculated independently. These modal responses are then combined to obtain the model’s overall response to the applied spectra. The response spectrum method enjoyswide acceptance as anaccuratemethodforpredictingtheresponse of any structural model to any arbitrary base excitation, particularly earthquakes. Building codes require a dynamics based procedure for some structures. This method satisfies this dynamic requirement. It is easier, faster and more accurate than the static procedure so there really is not any reason to use the static procedure. 3. Structural & Loading Details Table 1: Modeling and Loading of Structure 1 Plan Dimensions 30 x 30 m 2 Number of story G+20 2 Floor to floor height 3.6m 4 Slab thickness 150mm 5 Size of beam 450mm x 500mm 6 Size of column 600mm x 600mm 7 Thickness of infill wall 230mm 8 Thickness of slab 150mm, M40 9 Zone and zone factor III, 0.16 10 Importance factor 1.5 11 Response factor (R) 5 12 Grade of concrete and rebar in beam M35, Fe500 13 Grade of concrete (Slab) M35 14 Grade of concrete and rebar in column M40, Fe415 15 Grade of shear wall M40 16 Live load and floor finish load 3kN/ m2and 1kN/m2 kN/ 17 Top floor load 2kN/ m2 18 Masonry load Half brick wall, 7.2 kN/m m2 Equivalent Diagonal Strut Method is used for modelling the infill wall. In this method the infill wall is idealized as diagonal strut and the frame is modelled as beam or truss element. Frame analysis techniques are used for the elastic analysis. The idealization is based on the assumption that there is no bond between frame and infill. Figure 2: Plan of the bulding
  • 4. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 10 | Oct 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.34 | ISO 9001:2008 Certified Journal | Page 126 Figure 3: 3D layout of the structure IS 1893 (Part 1): 2016 Criteria for Earthquake Resistant Design of Structures deals with assessment of seismic loads on various structures and earthquake resistant design of buildings. As per IS 1893 (Part 1):2016, whenearthquakeforcesare considered on a structure in the limit state design of reinforced and prestressed concrete structures, 13 load combinations shall be accounted for. As per IS 1893:2016, for various loading classes as specified in IS 875 (Part 2), the seismic force shall be calculated for the full dead load plus the percentage of imposed load as given in below table. Table 2: Live Load Reduction Clause as per IS 1893:2016 Imposed Uniformity Distributed Floor Loads ( kN/ m² ) Percentage of ImposedLoad Up to and including 3.0 25 Above 3.0 50 4. Behavior of the cases to be analyzed: Six different cases are taken and analysed: Full Masonry Structure, Soft Storey at Ground Floor, Soft Storey at 5th Floor, SoftStorey at 10th Floor, SoftStorey at 15thFloor, Soft Storey at 20th Floor. Symmetrical constructions in bothplan and height show a better resistance during an earthquake than those that do not have this symmetry. Since the presence of a soft storey which has less rigidity than other storeys spoils the perpendicular symmetry of the construction, and if this fact was not taken into consideration, it causes the constructiontobeaffected bythe quake because the columns in this part are forced by the quake more than the ones in the other parts of the building. Studies conducted suggest that walls increase the rigidity at a certain degree in the construction. The soft storey configuration is possible in by different arrangement in the building. (a) (b) (c) (d) (e) (f) Figure 4: Behavior of structure with soft storey at different floor during earthquake
  • 5. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 10 | Oct 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.34 | ISO 9001:2008 Certified Journal | Page 127 Soft storey configuration in structures is a type of construction where any one storey of the building is more flexible (less stiff) when compared with other floors. This may be located at the bottom, or at any intermediate points, where the floorabove or below it may bestiffer compared to itself. This accounts to be a weak element in the perspective of seismic forces. This weakness may be a sharp variation in the stiffness, drift index orin the strength parameters.These variations result in the poor distribution of masses throughout the floor, which is undesirable. 5. RESULTS 5.1 BASE SHEAR Base reactions are assessed for all the cases and further calculations are doneaccordingly.Baseshearisrevieweddue to all the modes reported in the Response Spectrum Base Reaction Table. If the dynamic base shear reported is more than 85% of the static base shear, no further action is required. However, if dynamic base shear is less than 85% of the static base shear, then the scale factor should beadjusted such that the response spectrum base shear matches 85% of the static base shear. Base shearisanestimateofthemaximumexpectedlateral force that will occur due to seismicgroundmotionatthebase of a structure. It is a very important parameter for earthquake resistant design ofbuildings.Amongallthecases, base shear is highest for full masonry structure and least for soft storey at ground level. This indicates that the case 2, i.e. soft-storey at ground level is most vulnerable during earthquake. The whole structure is critical under this case. Full masonry structure is the most reliable one. Figure 5: Bar graph showing variations in base shear of all the cases on Y-axis 5.2 INTER-STOREY DRIFT INDEX Storey drift is the drift of one level of a multi- storey building relative to the level below. Lateral drift and inter- storey drift are commonly used damage parameter in structural analysis. In this study, lateral drift of the 3D building frame was analysed for earthquake load coming from long direction. Inter-storey drift index was also evaluated and tabulated which is given by Where, VUi – VUi-1 = Relative displacement between successive storey. hi = Storey height. It is observed that for all cases there is a sudden increment in drift index at soft storey level, which is due to absence of masonry infill. The lateralload is more effectiveat that floor. The drift index value of soft storey at ground floor of the building is more. The driftindexvalueisverylesswhen soft storey is at top of the building. 5.3 STOREY STIFFNESS Stiffness is the rigidity of an object i.e., the extenttowhich it resists deformation in response to an applied force. As per IS 1893:2016, soft storey is one in which the lateral stiffness is less than that in the storey above. As per IS 1893:2002,soft storey is one in which the lateral stiffness is less than 70 percent of that in the storey above or less than 80 per cent of the average lateral stiffness of the three storeys above. At the soft-storey level there is a decrement in the storey stiffness. The stiffness decreases as we move upwards, meaning that as the storey height increases, storey stiffness decreases. After the decrement point the previous curve proceeds. This means that the upper portion haslesservalue of storey stiffness than the lower portion. 6. CONCLUSIONS RC frame buildings with soft storey are known to perform poorly during in strong earthquake shaking. In this project, the seismic vulnerability of buildings with soft storey at different floor levels is shown through an example building. Tall building of G+20 storeys is provided with soft storey at different floor levels to be analysed for the load as per IS 1893:2016, using software package ETABS 2015. The building islocated in seismic zoneIII. The resultsmayhelpto the future construction of soft storey buildings. From the result it is concluded that,  The displacement ofstorey increasesatsoftstorey level due to increase in application of dynamic forces on it. The presence of infill wall can affect the seismic behaviour of frame structure to large extent, and the infill wall increases the stability of the building.
  • 6. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 10 | Oct 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.34 | ISO 9001:2008 Certified Journal | Page 128  There is a drop in the storey stiffness at softstorey level in all cases. From this more care is need design the columns in the soft storey. Infill panels increases the stiffness of the structure. Hence behaviour of building varies with the change in infill arrangements.  The buildings with soft storeys resist smaller forces as compared to the stiff structures. The base shear at different floor levels is lesser for the buildings with softstoreys as compared tothestiff buildings. The base shear in the building with no soft storey is found maximum i.e. 25482.2 kN.  On comparing the storey response of the cases, it is observed that the storey drift index in case of buildings with soft storey is very large as compared to a stiff building. This high relative drift index in the building lead to a largeamount of undesirable additional bending moments in columns which leads to the failure ofthe structure as a whole. In case of an open first storey frame structure, the storey drift index is very large than in the upper storeys i.e. 0.002068, which may cause the collapse of structure during strong earthquakeshaking.  The soft storey columns require more percentage of reinforcement.  It is advisable to provide soft storey at higher levels. The presence of walls in upper storey makes the much stiffer than open ground storey. Hence, the upper storey movealmosttogetherasa single block and most of the horizontal displacement of the building occurs in the soft ground storey itself such building movestoandfro when earthquake occurs. Thus it is clear that building with only column in the ground storey has poor performance during earthquake as compared to building with both wall and column in the ground storey. Earthquake vulnerability of buildings with open ground floors is well known around the world. For a building that is not provided any lateral load resistance component such as shear wall or bracing, the strength is consider very weak and easily fail during earthquake. Other possible schemes to achieve the above objective are: (i) Provision of stiffer columns in the first storey in case of ground soft storey, and (ii) Provision of a concrete service core in the building. The former is effective only in reducing the lateral drift demand on the first storey columns. However the latter is effective in reducing the driftas wellasthestrengthdemands on the soft storey columns REFERENCES [1] A. Madan, A. M. Reinhorn, J. B. Mander, R. E. Valles, “Modelling of Masonry Infill Panels for Structural Analysis”, Journal of Structural Engineering, October 1997. [2] Abhishek Arora, “Alternative Approach to Soft Storey in Seismic Analysis of R.C.C Building Structures”, April 2015. [3] Agarwal, P. and Shrikhande, M., “Earthquake Resistant Design of Structures”, PHI Publication, 2004. [4] Bhakti Narayan Harne, R. R. Shinde, “Seismic Performance of Multi-Storied RC Building with Soft Storey”, International Journal of Emerging Technology and Advanced Engineering, Volume 5/ pp.116-122/ 2015. [5] Bureau of Indian Standards, “Criteria for Earthquake Resistant Design Of Structures” IS: 1893 (Part I): 2016 (Sixth Revision). [6] Bureau of Indian Standards, “Code Of Practice For Design Loads (Other Than Earthquake) For Buildings And Structures: Special Loads And Combinations” IS: 875 ( Part 5 ) – 1997 (Second Revision). [7] Bureau of Indian Standards, “Plain and Reinforced Concrete – Code of Practice” IS: 456-2000 (Fourth Revision). [8] Bureau of Indian Standards, “Earthquake Resistant Design And Construction Of Buildings —Code Of Practice” IS: 4326-1993 (Second Revision). [9] C. V. R. Murty, “How do Brick Masonry houses behave during Earthquakes?”, Building Materials and Technology Promotion Council, New Delhi. [10] C. V. R. Murty, “Why are Open Ground Storey Buildings vulnerable in Earthquake?”, Indian Institute of Technology, Kanpur.