SlideShare a Scribd company logo
Module- optimizer ECOD
Feigin Electric solution-Module
Optimizer “ECOD”
 New product which allows you to optimize the
voltage within the norms laid down by
international standards of quality electricity.
 By optimizing the consumption savings of up to
10% more.
 Registers the change of power quality input and
output devices.
 Measures and records the power consumption and
energy consumption in almost any period of time.
 The device operates in three phases simultaneously.
 Increases the lifetime of electrical production.
 Not sensitive to instantaneous load.
 Large high contrast display with instant readings of
the physical quantities of electricity.
 Programming with the unit.
.
Benefits.
 1. Reducing power consumption (minimum 10%).
 2. Lightning / surge protection. It protects the entire
structure from lightning and surge suppressor. No
need to purchase equipment for individual protection
equipment.
 3. Reduction of harmonic distortion. Patented active
harmonic filter improves EMC mains and load.
 4. Power factor correction. Reduces reactive power, the
percentage increase in energy use and the reduction of
the load current to provide the required power.
 5. Balancing phase provides a uniform load on each of
the phases. It provides energy savings.
The principal distinguishing features of our device "module
optimizer - ECOD» and other voltage regulator in the power
supply.
1. The efficiency of our devices is 0.997 (all known stabilizers for industrial use,
efficiency does not exceed 0.96)
2. 2. The transmission ratio of the electric power network by the electromagnetic load
our device is 1:15 While all known stabilizers for industrial use power transmission
ratio is 1: 2 (this means that the capacity of the autotransformer all other known
stabilizers for industrial use shall be not less than half the power of the load, which
means that these devices are more dimensions, the greater the weight, cost a lot more.
These devices consume up to 5% of the electricity for their own needs - in connection
with which the devices does not make sense to use optimizers as power consumption.
3. 3. The power load can vary from 0 to 100%, which does not affect the quality of
regulation.
4. 4. The regulatory process takes place without breaking the circuit and distortion sine
wave voltage.
5. 5. Performance when switching does not exceed 20 ms.
6. 6. High efficiency and low cost devices allows their use in electric networks with a
voltage of more than 220V to optimize energy consumption, with payback periods of
less than 1.5 years, which can not provide any of the known devices.
Principle of works
Best Solutions to optimize energy
consumption!
 Do you know that current in a socket never complying
with standards 220 V or 230 V, 110 V or 120 V? Yes,
that statement is absolute truth!!!
 You barely found 220 V or 230V, 110 V or 120 V
(depends on country accepted standard) it’s almost
always plus or minus 5-10% !!!
 Usually, in large cities voltage close to the upper
tolerance range!!!
Best Solutions to optimize energy
consumption!
 For example, in a country where 220 V taken as a
basic in network will be 225V-235V and even more.
Distributors increase the voltage to control
subsidence at peak power consumption.
 This increase is a main cause of "unnecessary"
electricity use !!!
 By implementing our technology can optimize
energy consumption by reducing the voltage to
the border which close to the lowest acceptable
standards.
Best Solutions to optimize energy
consumption!
Why when we reduce the
voltage decreases
consumption?
The answer is simple: kW=
=U ( Volts) * I (Amps)*1000*PF
In the table we can clearly see how the
performance when adjusting the
voltage.
When the voltage between 210 - 220 V
efficiency of electrical equipment of
almost 100% and the most optimal
power consumption (for country with
standards of LOAD 220 V+-5% )
The graph of the example of how to optimize the
consumption by the voltage control while maintaining
the efficiency of the device near 100% (For Asynchronous motors )
График примера того, как оптимизировать
потребление посредством управления
напряжением (for MIX LOAD and LIGHTING)
The formula for calculating the
optimization of energy consumption
For MIX LOAD
 U1= Load without our device , I1 = Current without our device, R - resistance
P1= Power without our device

 U2= Load with our device, I2 = Current with our device,R - resistance
P2= Power without our device

 U3- step of transformation, U3=U1/18,3 ( 18,3 RATIO OF TRANSFORMERS)

 Check U1 i I1 by special equipment, R ( Ohms Law R=U/I), P1= U1*I1, , R=U1/I1

 U2=U1-U3 = U1 - (U1/18,3), I2= U2/ R ( Ohms Law R=U/R) , I2= U1-(U1/18,3)/R
 P2= U2*I2 = U1 - (U1/18,3)* U1-(U1/18,3)/R
 P2/P1 = ( U1 - (U1/18,3)* (U1-((U1/18,3)/(U1/I1))) / U1*I1
 ENERGY SAVINGS % =
 =100%- P2/P1 = 100 -( U1 - (U1/18,3)* (U1-((U1/18,3)/(U1/ I1))) / U1*I1
Range of products
 For MIX LOAD
 For Asynchronous motors
 For Street Lighting
 For HOME use
Areas of use
 SOLUTION FOR MIX LOAD
( FACTORY, SHOPING CENTERS, OFFICE BUILDINGS, HOTELS)
 SOLUTION FOR ASYNCHRONOUS MOTORS.
(Optimization of energy costs during operation of asynchronous
motors.)
(Optimization of energy costs when working oil pumps.)
 SOLUTION FOR STREET LIGHTING
 SOLUTION FOR POWER DISTRIBUTORS
( for energy savings)
(Аcomprehensive solution for power transmission losses)
(Problems in networks of 0.4 kV, overvoltage and undervoltage)

More Related Content

PPTX
In power point description and application
PPTX
Smart optimizer ecod description and application (in power point)
PPTX
Electrical Energy Meter
PPT
Energy meter
PDF
Energy meter presentation
PPTX
Electricity meter
PDF
Meba Energy Kwh Meter Electronic Catalogue
PPTX
single phase static energy meter
In power point description and application
Smart optimizer ecod description and application (in power point)
Electrical Energy Meter
Energy meter
Energy meter presentation
Electricity meter
Meba Energy Kwh Meter Electronic Catalogue
single phase static energy meter

What's hot (20)

PPTX
Industrial wiring
PPTX
Energy Meters
PPT
PROJECT - " PROGRAMMABLE ENERGY METER CALCULATOR"
PPT
Read electric meter
PPTX
Electrical energy meter
PPT
Energy meter
PDF
Final year project ideas for electrical engineering eepowerschool.com
DOCX
PPTX
Electrical Projects
PPTX
Presentation of automatic street light
PDF
Wsp supermarkets e
DOCX
Automatic street light control system
PPTX
Mains operated under voltage over voltage trip switch
PDF
Presentation of smart meter
PDF
Electrical and Electronics Engineering : Power electronics, THE GATE ACADEMY
PPT
Energy meter
DOCX
Anand P
PPTX
Company: Staco Solutions and Applications
PPTX
Major project presentation
PDF
Electric Transformers and Energy Efficiency
Industrial wiring
Energy Meters
PROJECT - " PROGRAMMABLE ENERGY METER CALCULATOR"
Read electric meter
Electrical energy meter
Energy meter
Final year project ideas for electrical engineering eepowerschool.com
Electrical Projects
Presentation of automatic street light
Wsp supermarkets e
Automatic street light control system
Mains operated under voltage over voltage trip switch
Presentation of smart meter
Electrical and Electronics Engineering : Power electronics, THE GATE ACADEMY
Energy meter
Anand P
Company: Staco Solutions and Applications
Major project presentation
Electric Transformers and Energy Efficiency
Ad

Viewers also liked (14)

PDF
Oratoria IBp1-tarea1
PPT
Trabajo 2.0
PDF
You tube promoted-videos
DOCX
UNIDAD 5
PPT
Pub Med Rss
PDF
Rse 2012
PPTX
The writingprocess
DOC
Reanudacion2
PDF
Ar m256 20111202-085420
PPTX
Slim Staan - Het comfort van staande werknemers vergroten geschreven door Pro...
PPTX
ระบบสารสนเทศ
PPTX
Wpływ User-Centered Design na rzeczywistość
PDF
Crucial Conversations In Social Media
PPTX
Immunogenetics
Oratoria IBp1-tarea1
Trabajo 2.0
You tube promoted-videos
UNIDAD 5
Pub Med Rss
Rse 2012
The writingprocess
Reanudacion2
Ar m256 20111202-085420
Slim Staan - Het comfort van staande werknemers vergroten geschreven door Pro...
ระบบสารสนเทศ
Wpływ User-Centered Design na rzeczywistość
Crucial Conversations In Social Media
Immunogenetics
Ad

Similar to Module optimizer ECOD - Best Solution for optimization energy consumption! (20)

PDF
Feigin Electric Co. Ltd.
PPTX
ANY ELECTRIC ENERGY SYSTEM CONSISTS OF THREE MAIN STAGES
PPT
Presentation tahir
PDF
Smart - Optimizer ECOD
PDF
Smart – Optimizer ECOD
PPT
2010 August Harmonics & Energy Efficiency
PPTX
energy efficiency in electrical designs-.pptx
PPTX
energyefficiency in electrical designs-.pptx
PPTX
Energy efficiency in electrical system
PPTX
Energy Efficiency in Electrical Systems.pptx
PPTX
PATENTED AND PROVEN ENERGY OPTIMIZATION SYSTEM WITH 8-12 % IMMEDIATE ENER...
PDF
Save energy and protect your facility with voltage optimisation
PPTX
ENERGY EFFICIENT MOTORS
PDF
4: Energy Management in Water Supply Systems - Motors
PPTX
21 GSR.pptx
PDF
IRJET- Automatic Load Sharing of Transformer
PDF
Baykee SL series solar inverter Optional AVR Function
PDF
3.10 eet in electrical systems
PDF
3.10 eet in_electrical_systems[1] - copy
Feigin Electric Co. Ltd.
ANY ELECTRIC ENERGY SYSTEM CONSISTS OF THREE MAIN STAGES
Presentation tahir
Smart - Optimizer ECOD
Smart – Optimizer ECOD
2010 August Harmonics & Energy Efficiency
energy efficiency in electrical designs-.pptx
energyefficiency in electrical designs-.pptx
Energy efficiency in electrical system
Energy Efficiency in Electrical Systems.pptx
PATENTED AND PROVEN ENERGY OPTIMIZATION SYSTEM WITH 8-12 % IMMEDIATE ENER...
Save energy and protect your facility with voltage optimisation
ENERGY EFFICIENT MOTORS
4: Energy Management in Water Supply Systems - Motors
21 GSR.pptx
IRJET- Automatic Load Sharing of Transformer
Baykee SL series solar inverter Optional AVR Function
3.10 eet in electrical systems
3.10 eet in_electrical_systems[1] - copy

Recently uploaded (20)

PDF
Network Security Unit 5.pdf for BCA BBA.
PDF
Approach and Philosophy of On baking technology
PPTX
Spectroscopy.pptx food analysis technology
PDF
Peak of Data & AI Encore- AI for Metadata and Smarter Workflows
PDF
cuic standard and advanced reporting.pdf
PDF
Diabetes mellitus diagnosis method based random forest with bat algorithm
PDF
Mobile App Security Testing_ A Comprehensive Guide.pdf
PDF
Blue Purple Modern Animated Computer Science Presentation.pdf.pdf
PDF
Architecting across the Boundaries of two Complex Domains - Healthcare & Tech...
PDF
Spectral efficient network and resource selection model in 5G networks
PDF
Reach Out and Touch Someone: Haptics and Empathic Computing
PDF
gpt5_lecture_notes_comprehensive_20250812015547.pdf
PDF
Encapsulation theory and applications.pdf
PDF
Unlocking AI with Model Context Protocol (MCP)
PPTX
ACSFv1EN-58255 AWS Academy Cloud Security Foundations.pptx
PDF
Assigned Numbers - 2025 - Bluetooth® Document
PPTX
KOM of Painting work and Equipment Insulation REV00 update 25-dec.pptx
PPTX
sap open course for s4hana steps from ECC to s4
PDF
Review of recent advances in non-invasive hemoglobin estimation
PDF
A comparative analysis of optical character recognition models for extracting...
Network Security Unit 5.pdf for BCA BBA.
Approach and Philosophy of On baking technology
Spectroscopy.pptx food analysis technology
Peak of Data & AI Encore- AI for Metadata and Smarter Workflows
cuic standard and advanced reporting.pdf
Diabetes mellitus diagnosis method based random forest with bat algorithm
Mobile App Security Testing_ A Comprehensive Guide.pdf
Blue Purple Modern Animated Computer Science Presentation.pdf.pdf
Architecting across the Boundaries of two Complex Domains - Healthcare & Tech...
Spectral efficient network and resource selection model in 5G networks
Reach Out and Touch Someone: Haptics and Empathic Computing
gpt5_lecture_notes_comprehensive_20250812015547.pdf
Encapsulation theory and applications.pdf
Unlocking AI with Model Context Protocol (MCP)
ACSFv1EN-58255 AWS Academy Cloud Security Foundations.pptx
Assigned Numbers - 2025 - Bluetooth® Document
KOM of Painting work and Equipment Insulation REV00 update 25-dec.pptx
sap open course for s4hana steps from ECC to s4
Review of recent advances in non-invasive hemoglobin estimation
A comparative analysis of optical character recognition models for extracting...

Module optimizer ECOD - Best Solution for optimization energy consumption!

  • 2. Feigin Electric solution-Module Optimizer “ECOD”  New product which allows you to optimize the voltage within the norms laid down by international standards of quality electricity.  By optimizing the consumption savings of up to 10% more.  Registers the change of power quality input and output devices.  Measures and records the power consumption and energy consumption in almost any period of time.  The device operates in three phases simultaneously.  Increases the lifetime of electrical production.  Not sensitive to instantaneous load.  Large high contrast display with instant readings of the physical quantities of electricity.  Programming with the unit. .
  • 3. Benefits.  1. Reducing power consumption (minimum 10%).  2. Lightning / surge protection. It protects the entire structure from lightning and surge suppressor. No need to purchase equipment for individual protection equipment.  3. Reduction of harmonic distortion. Patented active harmonic filter improves EMC mains and load.  4. Power factor correction. Reduces reactive power, the percentage increase in energy use and the reduction of the load current to provide the required power.  5. Balancing phase provides a uniform load on each of the phases. It provides energy savings.
  • 4. The principal distinguishing features of our device "module optimizer - ECOD» and other voltage regulator in the power supply. 1. The efficiency of our devices is 0.997 (all known stabilizers for industrial use, efficiency does not exceed 0.96) 2. 2. The transmission ratio of the electric power network by the electromagnetic load our device is 1:15 While all known stabilizers for industrial use power transmission ratio is 1: 2 (this means that the capacity of the autotransformer all other known stabilizers for industrial use shall be not less than half the power of the load, which means that these devices are more dimensions, the greater the weight, cost a lot more. These devices consume up to 5% of the electricity for their own needs - in connection with which the devices does not make sense to use optimizers as power consumption. 3. 3. The power load can vary from 0 to 100%, which does not affect the quality of regulation. 4. 4. The regulatory process takes place without breaking the circuit and distortion sine wave voltage. 5. 5. Performance when switching does not exceed 20 ms. 6. 6. High efficiency and low cost devices allows their use in electric networks with a voltage of more than 220V to optimize energy consumption, with payback periods of less than 1.5 years, which can not provide any of the known devices.
  • 6. Best Solutions to optimize energy consumption!  Do you know that current in a socket never complying with standards 220 V or 230 V, 110 V or 120 V? Yes, that statement is absolute truth!!!  You barely found 220 V or 230V, 110 V or 120 V (depends on country accepted standard) it’s almost always plus or minus 5-10% !!!  Usually, in large cities voltage close to the upper tolerance range!!!
  • 7. Best Solutions to optimize energy consumption!  For example, in a country where 220 V taken as a basic in network will be 225V-235V and even more. Distributors increase the voltage to control subsidence at peak power consumption.  This increase is a main cause of "unnecessary" electricity use !!!  By implementing our technology can optimize energy consumption by reducing the voltage to the border which close to the lowest acceptable standards.
  • 8. Best Solutions to optimize energy consumption! Why when we reduce the voltage decreases consumption? The answer is simple: kW= =U ( Volts) * I (Amps)*1000*PF
  • 9. In the table we can clearly see how the performance when adjusting the voltage. When the voltage between 210 - 220 V efficiency of electrical equipment of almost 100% and the most optimal power consumption (for country with standards of LOAD 220 V+-5% )
  • 10. The graph of the example of how to optimize the consumption by the voltage control while maintaining the efficiency of the device near 100% (For Asynchronous motors )
  • 11. График примера того, как оптимизировать потребление посредством управления напряжением (for MIX LOAD and LIGHTING)
  • 12. The formula for calculating the optimization of energy consumption For MIX LOAD  U1= Load without our device , I1 = Current without our device, R - resistance P1= Power without our device   U2= Load with our device, I2 = Current with our device,R - resistance P2= Power without our device   U3- step of transformation, U3=U1/18,3 ( 18,3 RATIO OF TRANSFORMERS)   Check U1 i I1 by special equipment, R ( Ohms Law R=U/I), P1= U1*I1, , R=U1/I1   U2=U1-U3 = U1 - (U1/18,3), I2= U2/ R ( Ohms Law R=U/R) , I2= U1-(U1/18,3)/R  P2= U2*I2 = U1 - (U1/18,3)* U1-(U1/18,3)/R  P2/P1 = ( U1 - (U1/18,3)* (U1-((U1/18,3)/(U1/I1))) / U1*I1  ENERGY SAVINGS % =  =100%- P2/P1 = 100 -( U1 - (U1/18,3)* (U1-((U1/18,3)/(U1/ I1))) / U1*I1
  • 13. Range of products  For MIX LOAD  For Asynchronous motors  For Street Lighting  For HOME use
  • 14. Areas of use  SOLUTION FOR MIX LOAD ( FACTORY, SHOPING CENTERS, OFFICE BUILDINGS, HOTELS)  SOLUTION FOR ASYNCHRONOUS MOTORS. (Optimization of energy costs during operation of asynchronous motors.) (Optimization of energy costs when working oil pumps.)  SOLUTION FOR STREET LIGHTING  SOLUTION FOR POWER DISTRIBUTORS ( for energy savings) (Аcomprehensive solution for power transmission losses) (Problems in networks of 0.4 kV, overvoltage and undervoltage)