Brochure
Global Office of Lisun Electronics Inc.
http://www.Lisungroup.com
Lisun Group (Hong Kong) Limited
Add: Room 803, Chevalier House, 45-51 Chatham Road South, Tsim Sha Tsui, KL, HK
Tel: 00852-68852050 Fax: 00852-30785638
Email: SalesHK@Lisungroup.com
Lisun Electronics (Shanghai) Co., Ltd
Add: 113-114, No. 1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road, Jiading
District, Shanghai, 201802, China
Tel: +86(21)5108 3341 Fax: +86(21)5108 3342
Email: SalesSH@Lisungroup.com
Lisun Electronics Inc. (USA)
Add: 445 S. Figueroa Street, Los Angeless, CA 90071, U.S.A.
Email: Sales@Lisungroup.com
Lisun China Factory
Add: NO. 37, Xiangyuan Road, Hangzhou City, Zhejiang Province, China
Tel: +86-189-1799-6096
Email: Engineering@Lisungroup.com
Leader in Lighting & Electrical Test Instruments
Rev. 2/14/2020
Moving Detector
Goniospectroradiometer
(LSG-5000CCD)
Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 1 -
1.System Configuration
A. LSG-5000CCD Goniospectroradiometer System:
 Goniometric Rotating Console: Japanese Mitsubishi Motor and German
Angle encoder System to keep the test accuracy. Both Far Field and Near
Field Test.
 High Reflective Moving Mirror: Special design and produced to keep high
reflective value.
 Goniometric Rotating Control Instrument in 19inch cabinet: It connects
to the PC and was controlled by the software.
 Goniometric Rotating Control Instrument in dark room: This can allow
the customer to control the rotating in the dark room when install the
lumainires but no need to control in the PC.
 Double Channel & High Precision Photometer
 Germany produced Class L Constant Temperature Photo Detector
 Cross-beam Laser System for Calibrating
 English Measuring Software
 Automatic Adjust Diaphragm: remote control to adjust the size of
diaphragm for the different diameter size luminaries test
 Two sets of luminaries Clamps: multi-functions
 Oversea Delivery and Packing: all of the instruments and accessories will
be packed with Fumigation free three plywood, include the delivery cost
to Shanghai sea port
B. SLS-150W DC Standard Light Intensity Lamp
C. LS2010 Digital Power Meter: High Accuracy to measure AC voltage, current,
power and power factor, also measure harmonic
D. DC3010 CC & CV DC Power Source: DC3010 output is 30V/10A, Option can
be DC6010 (output is 60V/10A) and DC12010 (output is 120V/10A)
E. LSP-1KVAR AC Power Source: 1KVA Pure Sine Wave AC Power Source
F. CASE-19IN 19inch Standard Instruments Cabinet.
G. LMS-9000B High Precision CCD Spectraidomeeter
H. CLAMP-9000 Accessories and Adjustable Tripod for LMS-9000B
Full View for LSG-5000CCD Moving Detector Goniospectroradiometer
Note: PC and Printer prepared by the customer (request at least one USB port)
Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 2 -
2. Measurement Principle
LSG-5000CCD Moving Detector Goniospectroradiometer is full meet LM-79 Clause
9.3.1 request. The tested lamp will keep burning position and be fixed, near field
detector move together with the big mirror in a line, and the far field detector will
move with the big mirror synchronously. The detector will always sense the light
directly from the luminaries.
The rotation priority is determined by the software. If mirror axle is took precedence
of rotation, the Goniospectroradiometer will continuously measure the luminous
intensity at each γ angle on a vertical plane determined by the C angle, the
measuring trace is equivalent to the longitude. Similarly, while the luminaries axle is
priority, the system will continuously measure the luminous intensity at each C
angle on a conical surface determined by the γ angle, the trace can be looked upon
the woof. See the following figure.
Measurement Principle
3. System Functions
Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 3 -
The LSG-5000CCD full meet LM-79 Clause 9.3.1, CIE and GB standards for
Goniophotometric of luminaries, this system is used to measure spatial luminous
intensity distribution of luminaries for floodlight, street lighting and interior lighting,
and other photometric parameters such as spatial iso-intensity curve, intensity
distribution curve of each section (shown in rectangular coordinate system or polar
coordinate system), iso-illuminance distribution curve, luminance limitation curve,
luminaries efficiency, glare grade, effective beam angles, upward luminous flux ratio,
downward luminous flux ratio, total luminous flux, effective luminous flux,
utilization factor and electric parameters (wattage, power factor, voltage and
current) of luminaries etc.
LSG-5000 Can test all of the above luminaires
4. Specifications
1) The tested luminaire rotates around the mirror with an angle of (γ)±180°(or
0-360°) and the tested luminaire rotates around itself with an angle of
(C)±180°(or 0-360°)
2) The accuracy of angle: 0.05° Resolution of angle: 0.001°
3) Luminosity Testing Range: Illuminance 0.001lx~99,999lx; Light Intensity
1.0cd~107
cd(detector)
4) Accuracy of photometry: Germany produced constant temperature photo
detector DIN5032-6/CIE pub1. No. 69 Class L
5) Testing Accuracy: 2%(Under Standard lamp); Stray Light: less than 0.1%
6) Work with high accuracy and quick CCD Spectroradiometer to measure
spatial color parameters.
7) Accuracy of chromaticity coordinate: ±0.0015 or ±0.0005(under standard A
lamp)
8) Spectral Range Wavelength: 380nm ~780nm; Accuracy of wavelength:
±0.5nm
9) English version software can run in Win7, Win8 or Win10.
Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 4 -
PS. The LSG-5000XCCD are special size which According to customer’s request
5. Laboratory Requirements
1) Room Requirements according to CIE
Model Dark Room (W*H*L) Operation Room(W*L)
LSG-5000BCCD 5*5*8~30m 4*4m
LSG-5000CCD 4*4*8~30m 4*4m
LSG-5000SCCD 4*3*8~30m 4*4m
P.S. The LSG-5000XCCD Lab room size will special design
 The dark room wall, ceiling and floor should be all coated with dull black paint or
be covered by black cloth and black carpet.
 Air-conditioner: be set in the dark room to control the temperature around
lamps to the standard value upon the CIE requirements.
Note: LISUN GROUP engineer dept will submit the Lab Design support documents
according to the customer’s real lab size after the formal purchase order was
confirmed
Model Number
LSG-5000B
(Big Size)
LSG-5000
(Standard Size)
LSG-5000S
(Standard Size)
Measure Size (mm) Diameter=1600 Diameter=1400 Diameter=900
Measure Weight (Kg) 50 40 30
Measure Power(W) 600V/10A,AC/DC 600V/10A,AC/DC 600V/10A,AC/DC
Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 5 -
Fig: LSG-5000CCD lab dark room view
2) Requirements of Eliminating the stray Light
Luminaires must be where the photo detector can only receive the light
reflected by the two moving mirror in the LSG-5000 system. The light given
off directly by the luminaries and reflected by the wall and floor is warded
off by the light fence. Internal surface of the dark room and dark path
together with the surface of the light fence should be painted unpolished
black or be covered by black cloth and black carpet.
3) Temperature of the Environment
Temperature around the lamp or luminaries must be 25℃±1℃ during the test.
Exceptions can be given according to relative lamps as following.
a. Tungsten Incandescent Lamp: 25℃±5℃
b. Double-caps Fluorescent Lamp: 25℃±1℃
c. High Pressure Mercury Lamp: 25℃±2℃
d. Metal Halogen Lamp: 25℃±2℃
Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 6 -
e. High Pressure Sodium Lamp: 25℃±2℃
f. Low Pressure Sodium Lamp: 25℃±2
4) Airflow
Airflow may be induced by natural aeration, air conditioner or movement of the
luminaries in the goniophotometer, but the speed of the airflow couldn’t
exceed 0.2m/s.
5) Vibration and shock
When the lamp is in lighting, the vibration couldn’t exceed 10m/s2(4 ~
3000Hz), or the moving scope of the lamp couldn’t exceed 30mm (at most
4Hz)
6) Smoke, Dust and Moisture
The test environment must free from smoke, dust or moisture. At the same
time, even not during the measurement, smoke, dust or moisture will also
influence the reflectance of the reflecting mirror and induce more stray light.
So, the test room must be kept clean, no smoke and dry. The humidity should
be less than 60% RH.
6. Service
1) Installation and Training
LISUN GROUP engineers will take responsibility for installation and Training of
the system at the customer’s
2) Period of Guarantee: 24 months
The service is for free except technician’s travel payment if the service
provided by LISUN GROUP implement at the customer’s.
3) Upgrading the applications software for free
7. Design Standard of Device
The construction, technical parameter, test & operate steps as well as data
processing software of LSG-5000CCD Moving Detector Goniospectroradiometer
meet the following requirements:
3.1 CIE Pub. NO.70,”The Measurement of Absolute Luminous Intensity
Distributions”
3.2 CIE DIV.Ⅱ-TC10,”Photometry of Luminaires”
3.3 IES LM-35-1989,”IES Approved Method for Photometric Testing of
Floodlights”
3.4 IES LM-31,”IES Approved Method for Photometric Testing of Roadway
Luminaires”
3.5 IES-LM-79, “Electrical & Photometric Measurements of Solid-State Lighting Products”
3.6 GB/T 7002-1986,“Luminosity Test of Flood Luminaires”
Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com
-Page 7 -
3.7 GB/T 9467-1988, “Luminosity Test of Indoor Luminaires”
3.8 GB/T 9468-1988, “Luminosity Test of Street Luminaires”
3.9 IES 61341 “Method of Measurement of Center Beam Intensity and Beam
Angle(s) of Reflector Lamp”
3.10 CIE Pub.NO.76, “Photometry-the CIE System of Physical Photometry”
8. Typical oversea market customers:
There are many world famous company and lab institute choose LISUN
Goniospecroradiometer, Please get the reference customers’ information
from Lisun Group Oversea Sales Dept.
9. Application Software
This system can export data files as following formats:
This kind of format files can be transferred by other illumination and luminaire
design software such as DiaLux
Application software can also implement essential calculation for lighting design as
iso-illuminance distribution curve on a working plane, luminance limitation curve,
luminaire efficiency, effective beam angle, upward luminous flux ratio, downward
luminous flux ratio, effective luminous flux, utilization factor curve etc.
The Next Page is the Test Report by the software:
Lisun Electronics Inc.
http://www.Lisungroup.com
Tel:+86(21)51083341
Fax:+86(21)51083342 Page 1 of 27 Pages
Report No.: LS1711 Test Time: 8/28/2017 17:02
Luminaire Property
Luminaire Manufacturer: LISUN
Luminaire Category: LED Philips 112 Luminaire Description: LS-71-83-8077
Lamp Catalog: LUMINUS Lamp Description: LUMINUS001
Number of Lamps: 1 Lumens per Lamp: 550
Luminous Length (mm): 50 Luminous Width (mm): 50
Luminous Height (mm): 100 Voltage: 119.9 V
Current: 0.530 A Power: 63.55 W
Power Factor: 0.999
Photometric Results
CIE Class: Direct Total Rated Lamp Lumens: 550.0 lm
Measurement Flux: 539.5 lm Efficiency: 98.08%
Downward Ratio: 98.08% Upward Ratio: 0.00%
Horizontal Diffuse Angle(50%): H99.2
Vertical Diffuse Angle(50%): V101.5
Luminaire Efficacy Rating (LER): 8.54 Central Intensity: 417.76 cd/klm
Max. Intensity: 429.28 cd/klm Pos of Max. Intensity: H45 V8
S/MH(C0/C180): 1.14 S/MH(C90/C270): 1.13
Picture Of Luminaire Luminous Intensity Distribution Curve
0
180
9090
1010
170170
2020
160160
3030
150150
4040
140140
5050
130130
6060
120120
7070
110110
8080
100100
536
429
321
214
107
Average Diffuse Angle(50%): 100.1°
C0-C180 C90-C270
Unit: cd/klm
C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0
Test Lab: LISUN Test Device: LSG-5000CCD
Test Type: TYPE C Distance: 8.000 m
Temperature: 24.5° Humidity: 60%
Operator: Jacky Inspector:
Lisun Electronics Inc.
http://www.Lisungroup.com
Tel:+86(21)51083341
Fax:+86(21)51083342 Page 2 of 27 Pages
Luminous Intensity Distribution Curve
0
180
9090
1010
170170
2020
160160
3030
150150
4040
140140
5050
130130
6060
120120
7070
110110
8080
100100
536
429
321
214
107
-180 -120 -60 0 60 120 180
0
107
214
321
429
536
C0-C180 C90-C270 Unit: cd/klm
C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0
Test Lab: LISUN Test Device: LSG-5000CCD
Test Type: TYPE C Distance: 8.000 m
Temperature: 24.5° Humidity: 60%
Operator: Jacky Inspector:
Lisun Electronics Inc.
http://www.Lisungroup.com
Tel:+86(21)51083341
Fax:+86(21)51083342 Page 3 of 27 Pages
Luminous Intensity Distribution Curve(cd/klm)
0
180
9090
1010
170170
2020
160160
3030
150150
4040
140140
5050
130130
6060
120120
7070
110110
8080
100100
536
429
321
214
107
cd/klm
C0-C180
C90-C270
η=98.08%
LUMINUS/LUMINUS001
C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0
Test Lab: LISUN Test Device: LSG-5000CCD
Test Type: TYPE C Distance: 8.000 m
Temperature: 24.5° Humidity: 60%
Operator: Jacky Inspector:
Lisun Electronics Inc.
http://www.Lisungroup.com
Tel:+86(21)51083341
Fax:+86(21)51083342 Page 4 of 27 Pages
Coefficients Of Utilization - Zonal Cavity Method
Curves of Luminaires vs Lighting Area
Spacing Criteria (0-180): 1.14
Spacing Criteria (90-270): 1.13
Spacing Criteria (Diagonal): 1.27
RC
RW
RF = 0.2RCR
0.8 0.8 0.8 0.8 0.7 0.7 0.7 0.7 0.5 0.5 0.5 0.3 0.3 0.3 0.1 0.1 0.1 0
0.7 0.5 0.3 0.1 0.7 0.5 0.3 0.1 0.5 0.3 0.1 0.5 0.3 0.1 0.5 0.3 0.1 0
0
1
2
3
4
5
6
7
8
9
10
117 117 117 117 114 114 114 114 109 109 109 104 104 104 100 100 100 98
107 103 99 95 105 101 97 94 96 93 91 93 90 88 89 87 85 83
98 91 84 79 96 89 83 78 85 80 76 82 78 74 79 76 73 71
90 80 73 67 88 79 72 66 76 70 65 73 68 64 71 66 63 61
83 72 63 57 81 70 63 57 68 61 56 66 60 55 64 59 55 52
76 64 56 50 74 63 55 49 61 54 49 59 53 48 58 52 48 46
71 58 50 44 69 57 49 44 56 48 43 54 48 43 52 47 42 40
66 53 45 39 64 52 44 39 51 44 38 49 43 38 48 42 38 36
61 49 40 35 60 48 40 35 47 40 35 45 39 34 44 38 34 32
57 45 37 32 56 44 37 31 43 36 31 42 36 31 41 35 31 29
54 41 34 29 53 41 34 29 40 33 29 39 33 28 38 32 28 27
10
2
2 3 4 5 6 7 8 910
3
2 3 4 5 6 7 8 910
4
2
3
4
5
6
7
8
10
15
20
25
30
N
A(sq.m)
Luminous Flux 1000 lm
Maintain Factor 0.70
Suspend Length 0.00m
Work Height 0.80m
Average Lux 100 lx
Line Type
Reflectivity(%)
Ceil Wall Floor
70 50 30
C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0
Test Lab: LISUN Test Device: LSG-5000CCD
Test Type: TYPE C Distance: 8.000 m
Temperature: 24.5° Humidity: 60%
Operator: Jacky Inspector:
Lisun Electronics Inc.
http://www.Lisungroup.com
Tel:+86(21)51083341
Fax:+86(21)51083342 Page 5 of 27 Pages
Isocandela (rectangle)
80
60
40
20
0
-20
-40
-60
-80
-80 -60 -40 -20 0 20 40 60 80
Horizontal(Deg)
Vertical(Deg)
24
3859
94
149
Imax (100%): 236 cd
( 10%): 24 cd ( 16%): 38 cd
( 25%): 59 cd ( 40%): 94 cd
( 63%): 149 cd (100%): 236 cd
C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0
Test Lab: LISUN Test Device: LSG-5000CCD
Test Type: TYPE C Distance: 8.000 m
Temperature: 24.5° Humidity: 60%
Operator: Jacky Inspector:
Lisun Electronics Inc.
http://www.Lisungroup.com
Tel:+86(21)51083341
Fax:+86(21)51083342 Page 6 of 27 Pages
Isocandela (sphere)
010
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170 180
270 292.5 315 337.5 0 22.5 45 67.5 90
Pavement Road
24
38
59
94
149
Imax (100%): 236 cd
( 10%): 24 cd ( 16%): 38 cd
( 25%): 59 cd ( 40%): 94 cd
( 63%): 149 cd (100%): 236 cd
C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0
Test Lab: LISUN Test Device: LSG-5000CCD
Test Type: TYPE C Distance: 8.000 m
Temperature: 24.5° Humidity: 60%
Operator: Jacky Inspector:
Lisun Electronics Inc.
http://www.Lisungroup.com
Tel:+86(21)51083341
Fax:+86(21)51083342 Page 7 of 27 Pages
IsoPPFD Plot
5
4
3
2
1
0
1
2
3
4
5
5 4 3 2 1 0 1 2 3 4 5
Vertical distance / mount height
Horizontaldistance/mountheight
0 0
0 0
0
0
Mounting Height: 10.0m Max PPFD(100%): 0.048 umol/s/m^2
( 1%): 0.000 umol/s/m^2 ( 2%): 0.001 umol/s/m^2
( 5%): 0.002 umol/s/m^2 ( 10%): 0.005 umol/s/m^2
( 20%): 0.010 umol/s/m^2 ( 50%): 0.024 umol/s/m^2
(100%): 0.048 umol/s/m^2
C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0
Test Lab: LISUN Test Device: LSG-5000CCD
Test Type: TYPE C Distance: 8.000 m
Temperature: 24.5° Humidity: 60%
Operator: Jacky Inspector:
Lisun Electronics Inc.
http://www.Lisungroup.com
Tel:+86(21)51083341
Fax:+86(21)51083342 Page 8 of 27 Pages
Roadway CU Curve
0
10
20
30
40
50
60
70
80
5 4 3 2 1 0 1 2 3 4 5
Pavement Road Street Width / Mounting Height
Efficiency(%)
Line Type Tilt Angle
0°
5°
10°
15°
20°
C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0
Test Lab: LISUN Test Device: LSG-5000CCD
Test Type: TYPE C Distance: 8.000 m
Temperature: 24.5° Humidity: 60%
Operator: Jacky Inspector:
Lisun Electronics Inc.
http://www.Lisungroup.com
Tel:+86(21)51083341
Fax:+86(21)51083342 Page 9 of 27 Pages
Lum Limit Curve
L(cd/sq.m) G45 G50 G55 G60 G65 G70 G75 G80 G85
C0
C90
C180
C270
26425 23238 19800 15600 10964 7073 4558 3190 2489
26091 23021 19522 15087 10385 6637 4285 3033 2352
22409 18493 14174 9978 6661 4520 3288 2598 2187
24002 20235 15829 11389 7657 5155 3661 2842 2402
Dazzle Quality Illuminance (lx)
1.15 A 2000 1000 500 <=300
1.50 B 2000 1000 500 <=300
1.85 C 2000 1000 500 <=300
2.20 D 2000 1000 500 <=300
2.55 E 2000 1000 500 <=300
a b c d e f g h
6 7 8 9 1000 2 3 4 5 6 7 8 9 10000 2 3 4
85
75
65
55
45
Gamma
8
6
4
3
2
a b c d e f g h
a/hs
L(cd/sq.m)C90 C270
6 7 8 9 1000 2 3 4 5 6 7 8 9 10000 2 3 4
85
75
65
55
45
Gamma
8
6
4
3
2
a b c d e f g h
a/hs
L(cd/sq.m)C0 C180
C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0
Test Lab: LISUN Test Device: LSG-5000CCD
Test Type: TYPE C Distance: 8.000 m
Temperature: 24.5° Humidity: 60%
Operator: Jacky Inspector:
Lisun Electronics Inc.
http://www.Lisungroup.com
Tel:+86(21)51083341
Fax:+86(21)51083342 Page 10 of 27 Pages
PPFD at a Distance
Dist(m) PPFD
(umol/s/m^2)
Dh/Dv_B(m) S_B(sq.m) PPFDav_B
Dh/Dv_F(m) S_F(sq.m) PPFDav_F
(umol/s/m^2)
5.0 0.189 11.67/12.21 113.4 0.040
33.62/34.94 947.0 0.002
1.0 4.728 2.33/2.44 4.5 1.004
6.72/6.99 37.9 0.051
2.0 1.182 4.67/4.89 18.1 0.251
13.45/13.98 151.5 0.013
3.0 0.525 7.00/7.33 40.8 0.112
20.17/20.96 340.9 0.006
4.0 0.295 9.33/9.77 72.5 0.063
26.89/27.95 606.1 0.003
Beam Angle(B): H98.8 V101.4 Field Angle(F): H146.9 V148.1
Dh
Dv
C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0
Test Lab: LISUN Test Device: LSG-5000CCD
Test Type: TYPE C Distance: 8.000 m
Temperature: 24.5° Humidity: 60%
Operator: Jacky Inspector:
Lisun Electronics Inc.
http://www.Lisungroup.com
Tel:+86(21)51083341
Fax:+86(21)51083342 Page 11 of 27 Pages
Vertical IsoPPFD Plot
1
2
3
4
5
6
7
8
9
10
11
0 1 2 3 4 5 6 7 8 9 10
Horizontal distance(m)
VerticalHeight(m)
0
0
0
0
1
2
Lowest(m): 1.0m Highest(m): 11.000m Max PPFD: 4.7 umol/s/m^2
( 1%): 0.047 umol/s/m^2 ( 2%): 0.095 umol/s/m^2
( 5%): 0.236 umol/s/m^2 ( 10%): 0.473 umol/s/m^2
( 20%): 0.946 umol/s/m^2 ( 50%): 2.364 umol/s/m^2
(100%): 4.728 umol/s/m^2
C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0
Test Lab: LISUN Test Device: LSG-5000CCD
Test Type: TYPE C Distance: 8.000 m
Temperature: 24.5° Humidity: 60%
Operator: Jacky Inspector:
Lisun Electronics Inc.
http://www.Lisungroup.com
Tel:+86(21)51083341
Fax:+86(21)51083342 Page 12 of 27 Pages
AreaFluxTable
Vertical plane
Horizontalplane
00
-10
10
-20
20
-30
30
-40
40
-50
50
-60
60
-70
70
-80
80
-90
90
Flux(T)
Flux(E)
00-1010-2020-3030-4040-5050-6060-7070-8080-9090
Flux(T)Flux(E)
0.00.10.20.30.40.50.60.70.70.70.70.60.60.50.40.30.20.1
0.00.20.30.40.60.80.91.11.11.11.11.00.80.70.50.30.20.1
0.10.20.30.60.91.31.72.12.42.42.21.91.41.00.70.40.20.1
0.10.20.40.81.52.43.44.34.74.84.33.62.61.71.00.50.20.1
0.10.20.51.22.33.95.46.46.96.96.45.44.12.81.50.70.30.1
0.10.20.61.63.35.26.77.88.48.47.86.75.33.82.20.90.30.1
0.10.30.82.04.16.07.69.09.910.09.37.96.34.62.71.10.30.1
0.10.30.92.44.56.48.410.211.511.610.79.07.05.13.11.30.40.1
0.10.30.92.54.66.78.911.012.412.511.79.97.55.43.41.40.40.1
0.10.30.92.54.66.78.911.012.412.912.110.07.65.53.51.50.40.1
0.10.30.92.34.46.48.510.411.812.311.59.57.35.33.31.40.40.1
0.10.20.82.04.05.97.69.310.510.810.18.66.85.03.01.20.30.1
0.10.20.61.63.35.16.78.08.99.18.67.66.24.52.51.00.30.1
0.10.20.51.22.33.95.56.77.47.67.36.55.33.61.90.80.30.1
0.10.20.40.81.52.53.74.95.75.95.64.83.72.31.20.60.20.1
0.10.20.30.50.91.32.02.63.13.33.02.61.91.30.80.40.20.1
0.00.20.30.40.60.70.91.11.31.41.31.21.00.70.50.30.20.1
0.00.10.20.30.40.50.60.60.70.70.70.60.60.50.40.30.20.1
1.0
0.0
3.8
0.1
9.9
6.3
23.5
20.4
44.1
41.1
66.3
63.3
88.0
85.2
107.2
104.4
119.7
117.0
122.3
119.7
114.3
111.7
97.3
94.6
76.0
73.3
54.2
51.6
32.6
30.0
14.4
11.7
4.9
1.7
1.1
0.0
7.70.0
11.11.5
19.816.4
36.534.9
55.054.0
69.468.7
81.881.3
92.992.4
99.799.2
100.8100.4
96.295.7
86.485.9
74.473.7
61.060.0
44.042.6
24.521.6
12.13.9
7.40.0
981
932
Unit:lm/klm
C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0
Test Lab: LISUN Test Device: LSG-5000CCD
Test Type: TYPE C Distance: 8.000 m
Temperature: 24.5° Humidity: 60%
Operator: Jacky Inspector:
Lisun Electronics Inc.
http://www.Lisungroup.com
Tel:+86(21)51083341
Fax:+86(21)51083342 Page 13 of 27 Pages
The Average PPFD Effective Figure
Beam Angle:20.0°Height Avg./Nadir. PPFD Diameter / Area
10.0m 0.05/ 3.53m / 9.77sq.m0.047umol/s/m^2
20.0m 0.01/ 7.05m / 39.07sq.m0.012umol/s/m^2
30.0m 0.01/ 10.58m / 87.91sq.m0.005umol/s/m^2
40.0m 0.00/ 14.11m / 156.28sq.m0.003umol/s/m^2
50.0m 0.00/ 17.63m / 244.19sq.m0.002umol/s/m^2
PPF Out: 0.448umol/s
C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0
Test Lab: LISUN Test Device: LSG-5000CCD
Test Type: TYPE C Distance: 8.000 m
Temperature: 24.5° Humidity: 60%
Operator: Jacky Inspector:
Lisun Electronics Inc.
http://www.Lisungroup.com
Tel:+86(21)51083341
Fax:+86(21)51083342 Page 14 of 27 Pages
UGR Table
Reflectance:
Room dimensions
Ceiling (cavity)
Wall
Reference plane
X=2H Y=2H
3H
4H
6H
8H
12H
X=4H Y=2H
3H
4H
6H
8H
12H
X=8H Y=4H
6H
8H
12H
X=12H Y=4H
6H
8H
Viewed crosswise Viewed endwise
0.7
0.5
0.2
0.7
0.5
0.2
0.7
0.3
0.2
0.7
0.3
0.2
0.5
0.5
0.2
0.5
0.5
0.2
0.5
0.3
0.2
0.5
0.3
0.2
0.3
0.3
0.2
0.3
0.3
0.2
22.5 22.123.8 23.422.8 22.424.1 23.624.3 23.9
23.1 22.624.3 23.823.4 22.924.6 24.124.9 24.3
23.3 22.724.4 23.823.6 23.124.7 24.125.0 24.4
23.3 22.824.4 23.823.7 23.124.7 24.125.0 24.5
23.4 22.824.4 23.823.7 23.224.7 24.125.0 24.5
23.4 22.824.3 23.823.8 23.224.7 24.125.0 24.5
22.8 22.423.9 23.523.1 22.724.2 23.824.5 24.1
23.5 23.024.4 24.023.8 23.424.8 24.325.1 24.6
23.7 23.224.5 24.024.1 23.624.9 24.425.2 24.8
23.8 23.324.6 24.124.2 23.724.9 24.525.3 24.9
23.9 23.424.6 24.124.3 23.825.0 24.525.4 24.9
23.9 23.424.6 24.124.4 23.925.0 24.525.4 24.9
23.7 23.224.4 23.924.1 23.724.8 24.325.2 24.7
23.9 23.424.5 24.024.3 23.924.9 24.425.4 24.9
24.0 23.524.5 24.024.5 24.024.9 24.525.4 25.0
24.1 23.724.5 24.124.6 24.225.0 24.625.5 25.1
23.6 23.224.3 23.824.1 23.724.7 24.325.1 24.7
23.9 23.424.4 23.924.4 23.924.8 24.425.3 24.9
24.0 23.624.4 24.024.5 24.124.9 24.525.4 25.0
Variations with the observer position at spacings:
S=1.0H +0.2/-0.3 +0.3/-0.5
S=1.5H +0.6/-1.1 +0.8/-1.6
S=2.0H +1.6/-2.7 +1.8/-2.7
Calculate in accordance with CIE Pub.117. The table is revised with 550lm (8log(F/F0) = -2.1).
C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0
Test Lab: LISUN Test Device: LSG-5000CCD
Test Type: TYPE C Distance: 8.000 m
Temperature: 24.5° Humidity: 60%
Operator: Jacky Inspector:
Lisun Electronics Inc.
http://www.Lisungroup.com
Tel:+86(21)51083341
Fax:+86(21)51083342 Page 15 of 27 Pages
FLUX DISTRIBUTION TABLE BASED ON THE IESNA LUMINAIRE CLASSIFICATION SYSTEM
0°
30°30°
60°60°
80°80°
100°100°
90°90°
FRONTBACK
FLBL
FMBM
FHBH
FVHBVH
UL UL
UH
ZONE LUMENS % LAMP LUMENS
FORWARD LIGHT 279 50.7
FL ( 0°-30°) 86 15.7
FM (30°-60°) 147 26.7
FH (60°-80°) 39 7.1
FVH (80°-90°) 7 1.2
BACK LIGHT 261 47.4
BL ( 0°-30°) 84 15.2
BM (30°-60°) 137 24.9
BH (60°-80°) 34 6.1
BVH (80°-90°) 7 1.2
UP LIGHT 0 0.0
UL (90°-100°) 0 0.0
UH (100°-180°) 0 0.0
TRAPPED LIGHT 11 1.9
BUG(Backlight,Uplight,Glare) Rating Base On TM-15-07
Asymmetrical Luminaire Types
(Type I,II,III,IV)
B0 U0 G0
Quadrilateral Symmetrical Luminaire Types
(Type V,Area Light)
B0 U0 G0
C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0
Test Lab: LISUN Test Device: LSG-5000CCD
Test Type: TYPE C Distance: 8.000 m
Temperature: 24.5° Humidity: 60%
Operator: Jacky Inspector:
Lisun Electronics Inc.
http://www.Lisungroup.com
Tel:+86(21)51083341
Fax:+86(21)51083342 Page 16 of 27 Pages
LCS Graph
5.3%
10.7%
16.0%
21.3%
26.7%
0° FL 0°-30°
86 lm
15.7%
BL 0°-30°
84 lm
15.2%
FM 30°-60°
147 lm
26.7%
BM 30°-60°
137 lm
24.9%
FH 60°-80°
39 lm
7.1%
BH 60°-80°
34 lm
6.1%
FVH 80°-90°
7 lm
1.2%
BVH 80°-90°
7 lm
1.2%
UL 90°-100°
0 lm
0.0%
UL 90°-100°
0 lm
0.0%
UH 100°-180°
0 lm
0.0%
Trapped Light:11 lm,1.9%
Scale= MAX LCS%
Back Light Forward Light
C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0
Test Lab: LISUN Test Device: LSG-5000CCD
Test Type: TYPE C Distance: 8.000 m
Temperature: 24.5° Humidity: 60%
Operator: Jacky Inspector:
Lisun Electronics Inc.
http://www.Lisungroup.com
Tel:+86(21)51083341
Fax:+86(21)51083342 Page 17 of 27 Pages
Color Properties
Chromaticity Coordinate: x=0.4651 y=0.4138 u(u')=0.2645 v=0.3529 v'=0.5293
Correlated Color Temperature: Tc=2653K (duv=0.00074)
Measurement Flux: 539.5lm, PAR: 2.189W, PPF: 11.100umol/s
Peak Wavelength: 800nm Half Bandwidth: 185.4nm
Dominant Wavelength: 584.2nm Color Purity: 0.638
Color Ratio: R=0.269 G=0.704 B=0.027
TM30: Rf=99, Rg=99
Color Render Index: Ra= 99.5
R1 =99.5 R2 =99.5 R3 =99.5 R4 =99.4 R5 =99.3 R6 =99.1 R7 =99.7 R8 =99.6
R9 =98.8 R10=98.8 R11=99.3 R12=98.1 R13=99.4 R14=99.7 R15=99.3
Color Quality Scale: Qa= 96.2 Qf= 98.8 Qp= 98.5 Qg= 96.4
Q1 =96.7 Q2 =97.2 Q3 =97.1 Q4 =96.9 Q5 =96.6 Q6 =96.2 Q7 =95.9 Q8 =95.7
Q9 =95.0 Q10=95.5 Q11=96.0 Q12=96.5 Q13=96.7 Q14=97.2 Q15=0.0
1.2
1.0
0.8
0.6
0.4
0.2
0.0
380 430 480 530 580 630 680 730 780
CIE1931 CHROMATICITY DIAGRAM
0 x
y
0.1
.2
0.3
.4
0.5
.6
0.7
.8
C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0
Test Lab: LISUN Test Device: LSG-5000CCD
Test Type: TYPE C Distance: 8.000 m
Temperature: 24.5° Humidity: 60%
Operator: Jacky Inspector:
Lisun Electronics Inc.
http://www.Lisungroup.com
Tel:+86(21)51083341
Fax:+86(21)51083342 Page 18 of 27 Pages
Utilisation Factor Table(Floor cavity)
Utilisation Factors UF(F)
Rating:64W Photometrically tested without ceiling board.
Multiply UF values by service correction factors
Calculate in accordance with CIBSE Technical Memorandum NO.5 1980
SHR NOM = 1.25
Room Reflectance
Ceiling Wall Floor
Room Index(RI)
0.75 1.00 1.25 1.50 2.00 2.50 3.00 4.00 5.00
0.70 0.200.50
0.30
0.20
0.50 0.200.50
0.30
0.20
0.30 0.200.50
0.30
0.20
0.00 0.000.00
0.59 0.69 0.76 0.81 0.88 0.92 0.96 1.00 1.02
0.52 0.62 0.70 0.75 0.82 0.87 0.91 0.96 0.99
0.47 0.57 0.64 0.70 0.78 0.83 0.87 0.92 0.96
0.58 0.67 0.74 0.79 0.85 0.89 0.92 0.96 0.98
0.51 0.61 0.68 0.73 0.80 0.85 0.88 0.93 0.95
0.46 0.56 0.64 0.69 0.76 0.81 0.85 0.90 0.93
0.56 0.66 0.72 0.76 0.82 0.86 0.89 0.92 0.94
0.51 0.60 0.67 0.72 0.78 0.82 0.86 0.90 0.92
0.46 0.56 0.63 0.68 0.75 0.79 0.83 0.87 0.90
0.44 0.54 0.60 0.65 0.71 0.76 0.79 0.83 0.86
C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0
Test Lab: LISUN Test Device: LSG-5000CCD
Test Type: TYPE C Distance: 8.000 m
Temperature: 24.5° Humidity: 60%
Operator: Jacky Inspector:
Lisun Electronics Inc.
http://www.Lisungroup.com
Tel:+86(21)51083341
Fax:+86(21)51083342 Page 19 of 27 Pages
Utilisation Factor Table(Wall)
Utilisation Factors UF(W)
Rating:64W Photometrically tested without ceiling board.
Multiply UF values by service correction factors
Calculate in accordance with CIBSE Technical Memorandum NO.5 1980
SHR NOM = 1.25
Room Reflectance
Ceiling Wall Floor
Room Index(RI)
0.75 1.00 1.25 1.50 2.00 2.50 3.00 4.00 5.00
0.70 0.200.50
0.30
0.20
0.50 0.200.50
0.30
0.20
0.30 0.200.50
0.30
0.20
0.00 0.000.00
0.92 0.75 0.64 0.55 0.44 0.37 0.31 0.25 0.20
0.77 0.64 0.56 0.49 0.40 0.34 0.29 0.23 0.19
0.66 0.56 0.49 0.44 0.36 0.31 0.27 0.22 0.18
0.89 0.72 0.61 0.53 0.42 0.38 0.30 0.23 0.19
0.75 0.63 0.54 0.47 0.38 0.32 0.28 0.22 0.18
0.65 0.55 0.48 0.43 0.35 0.30 0.26 0.21 0.18
0.86 0.69 0.59 0.51 0.40 0.33 0.29 0.22 0.18
0.74 0.61 0.52 0.46 0.37 0.31 0.27 0.21 0.18
0.65 0.55 0.47 0.42 0.34 0.29 0.25 0.20 0.17
0.54 0.45 0.38 0.33 0.27 0.23 0.19 0.15 0.13
C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0
Test Lab: LISUN Test Device: LSG-5000CCD
Test Type: TYPE C Distance: 8.000 m
Temperature: 24.5° Humidity: 60%
Operator: Jacky Inspector:
Lisun Electronics Inc.
http://www.Lisungroup.com
Tel:+86(21)51083341
Fax:+86(21)51083342 Page 20 of 27 Pages
Utilisation Factor Table(Ceiling cavity)
Utilisation Factors UF(C)
Rating:64W Photometrically tested without ceiling board.
Multiply UF values by service correction factors
Calculate in accordance with CIBSE Technical Memorandum NO.5 1980
SHR NOM = 1.25
Room Reflectance
Ceiling Wall Floor
Room Index(RI)
0.75 1.00 1.25 1.50 2.00 2.50 3.00 4.00 5.00
0.70 0.200.50
0.30
0.20
0.50 0.200.50
0.30
0.20
0.30 0.200.50
0.30
0.20
0.00 0.000.00
0.16 0.17 0.18 0.18 0.19 0.20 0.20 0.21 0.21
0.09 0.11 0.12 0.13 0.15 0.16 0.17 0.18 0.19
0.05 0.06 0.08 0.09 0.11 0.13 0.14 0.16 0.17
0.15 0.16 0.17 0.18 0.19 0.19 0.19 0.20 0.20
0.09 0.11 0.12 0.13 0.14 0.15 0.16 0.17 0.18
0.05 0.06 0.08 0.09 0.11 0.12 0.14 0.15 0.16
0.15 0.16 0.16 0.17 0.18 0.18 0.19 0.19 0.19
0.09 0.10 0.12 0.13 0.14 0.15 0.16 0.17 0.18
0.05 0.06 0.08 0.09 0.11 0.12 0.13 0.15 0.16
NA NA NA NA NA NA NA NA NA
C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0
Test Lab: LISUN Test Device: LSG-5000CCD
Test Type: TYPE C Distance: 8.000 m
Temperature: 24.5° Humidity: 60%
Operator: Jacky Inspector:
Lisun Electronics Inc.
http://www.Lisungroup.com
Tel:+86(21)51083341
Fax:+86(21)51083342 Page 21 of 27 Pages
Zonal Lumen
Gamma Imean Zonal Flux Sum Zonal Flux Rel Zonal FluxSum Rel Zonal Flux
[°] [cd/klm] [lm] [lm] [%] [%]
0.0-1.0 419.2 0.2 0.2 0.04 0.04
1.0-2.0 419.0 0.7 0.9 0.12 0.16
2.0-3.0 418.8 1.1 2.0 0.20 0.36
3.0-4.0 418.4 1.5 3.5 0.28 0.64
4.0-5.0 417.8 2.0 5.5 0.36 1.00
5.0-6.0 417.0 2.4 7.9 0.44 1.44
6.0-7.0 416.1 2.8 10.8 0.52 1.96
7.0-8.0 414.7 3.3 14.0 0.59 2.55
8.0-9.0 413.0 3.7 17.7 0.67 3.22
9.0-10.0 411.1 4.1 21.8 0.74 3.96
10.0-11.0 409.0 4.5 26.3 0.82 4.78
11.0-12.0 406.6 4.9 31.2 0.89 5.67
12.0-13.0 403.9 5.3 36.4 0.96 6.63
13.0-14.0 400.7 5.6 42.1 1.03 7.65
14.0-15.0 397.1 6.0 48.1 1.09 8.74
15.0-16.0 393.3 6.3 54.4 1.15 9.90
16.0-17.0 389.1 6.7 61.1 1.21 11.11
17.0-18.0 384.7 7.0 68.1 1.27 12.38
18.0-19.0 379.9 7.3 75.3 1.32 13.70
19.0-20.0 374.9 7.5 82.9 1.37 15.07
20.0-21.0 369.6 7.8 90.7 1.42 16.49
21.0-22.0 364.0 8.0 98.7 1.46 17.95
22.0-23.0 358.4 8.3 107.0 1.50 19.46
23.0-24.0 352.7 8.5 115.5 1.54 21.00
24.0-25.0 346.9 8.7 124.2 1.58 22.58
25.0-26.0 341.0 8.9 133.0 1.61 24.19
26.0-27.0 335.1 9.0 142.0 1.64 25.83
27.0-28.0 329.1 9.2 151.2 1.67 27.49
28.0-29.0 323.2 9.3 160.5 1.69 29.18
29.0-30.0 317.4 9.4 169.9 1.71 30.90
30.0-31.0 311.6 9.5 179.5 1.73 32.63
31.0-32.0 306.0 9.6 189.1 1.75 34.39
32.0-33.0 300.5 9.7 198.9 1.77 36.16
33.0-34.0 295.1 9.8 208.7 1.79 37.94
34.0-35.0 289.8 9.9 218.6 1.80 39.74
35.0-36.0 284.6 10.0 228.6 1.81 41.55
C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0
Test Lab: LISUN Test Device: LSG-5000CCD
Test Type: TYPE C Distance: 8.000 m
Temperature: 24.5° Humidity: 60%
Operator: Jacky Inspector:
Lisun Electronics Inc.
http://www.Lisungroup.com
Tel:+86(21)51083341
Fax:+86(21)51083342 Page 22 of 27 Pages
Zonal Lumen (Continue 1)
Gamma Imean Zonal Flux Sum Zonal Flux Rel Zonal FluxSum Rel Zonal Flux
[°] [cd/klm] [lm] [lm] [%] [%]
36.0-37.0 279.5 10.0 238.6 1.82 43.38
37.0-38.0 274.5 10.1 248.7 1.83 45.21
38.0-39.0 269.7 10.1 258.8 1.84 47.05
39.0-40.0 264.9 10.2 268.9 1.85 48.90
40.0-41.0 259.8 10.2 279.1 1.85 50.75
41.0-42.0 254.9 10.2 289.3 1.85 52.60
42.0-43.0 250.1 10.2 299.5 1.85 54.46
43.0-44.0 245.1 10.2 309.7 1.85 56.31
44.0-45.0 240.0 10.1 319.8 1.84 58.15
45.0-46.0 234.7 10.1 329.9 1.84 59.99
46.0-47.0 229.3 10.0 340.0 1.82 61.81
47.0-48.0 223.6 9.9 349.9 1.81 63.62
48.0-49.0 217.8 9.8 359.7 1.79 65.41
49.0-50.0 211.7 9.7 369.4 1.77 67.17
50.0-51.0 205.1 9.5 379.0 1.74 68.91
51.0-52.0 198.2 9.4 388.3 1.70 70.61
52.0-53.0 191.1 9.1 397.5 1.66 72.27
53.0-54.0 183.6 8.9 406.4 1.62 73.89
54.0-55.0 175.9 8.6 415.0 1.57 75.46
55.0-56.0 167.8 8.3 423.4 1.52 76.98
56.0-57.0 159.5 8.0 431.4 1.46 78.43
57.0-58.0 151.0 7.7 439.1 1.40 79.83
58.0-59.0 142.4 7.3 446.4 1.33 81.16
59.0-60.0 133.8 7.0 453.3 1.26 82.43
60.0-61.0 125.2 6.6 459.9 1.19 83.62
61.0-62.0 116.6 6.2 466.1 1.12 84.75
62.0-63.0 108.3 5.8 471.9 1.05 85.80
63.0-64.0 100.2 5.4 477.3 0.98 86.78
64.0-65.0 92.5 5.0 482.3 0.92 87.70
65.0-66.0 85.2 4.7 487.0 0.85 88.55
66.0-67.0 78.3 4.3 491.4 0.79 89.34
67.0-68.0 71.9 4.0 495.4 0.73 90.07
68.0-69.0 66.0 3.7 499.1 0.67 90.74
69.0-70.0 60.6 3.4 502.5 0.62 91.36
70.0-71.0 55.7 3.2 505.6 0.58 91.94
71.0-72.0 51.2 2.9 508.6 0.53 92.47
C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0
Test Lab: LISUN Test Device: LSG-5000CCD
Test Type: TYPE C Distance: 8.000 m
Temperature: 24.5° Humidity: 60%
Operator: Jacky Inspector:
Lisun Electronics Inc.
http://www.Lisungroup.com
Tel:+86(21)51083341
Fax:+86(21)51083342 Page 23 of 27 Pages
Zonal Lumen (Continue 2)
Gamma Imean Zonal Flux Sum Zonal Flux Rel Zonal FluxSum Rel Zonal Flux
[°] [cd/klm] [lm] [lm] [%] [%]
72.0-73.0 47.2 2.7 511.3 0.49 92.96
73.0-74.0 43.5 2.5 513.8 0.46 93.42
74.0-75.0 40.4 2.3 516.2 0.43 93.85
75.0-76.0 37.6 2.2 518.3 0.40 94.25
76.0-77.0 35.1 2.1 520.4 0.37 94.62
77.0-78.0 32.9 1.9 522.3 0.35 94.97
78.0-79.0 30.9 1.8 524.2 0.33 95.30
79.0-80.0 29.1 1.7 525.9 0.31 95.62
80.0-81.0 27.6 1.6 527.5 0.30 95.91
81.0-82.0 26.2 1.6 529.1 0.28 96.20
82.0-83.0 24.9 1.5 530.6 0.27 96.47
83.0-84.0 23.8 1.4 532.0 0.26 96.73
84.0-85.0 22.7 1.4 533.4 0.25 96.98
85.0-86.0 21.8 1.3 534.7 0.24 97.21
86.0-87.0 21.0 1.3 535.9 0.23 97.44
87.0-88.0 20.1 1.2 537.2 0.22 97.66
88.0-89.0 19.4 1.2 538.3 0.21 97.88
89.0-90.0 18.7 1.1 539.5 0.21 98.08
C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0
Test Lab: LISUN Test Device: LSG-5000CCD
Test Type: TYPE C Distance: 8.000 m
Temperature: 24.5° Humidity: 60%
Operator: Jacky Inspector:
Lisun Electronics Inc.
http://www.Lisungroup.com
Tel:+86(21)51083341
Fax:+86(21)51083342 Page 24 of 27 Pages
Color Properties
Average Color Nonuniformity:∆u'=-0.2642,∆v'=-0.5294,∆u'v'=0.591689
Maximum Color Nonuniformity:∆u'=-0.0004,∆v'=0.0002,∆u'v'=0.000418
Average Color(u',v'):(0.2643,0.5294)Color Distribution Datas: (u',v')
GC 0.0 90.0 180.0 270.0
0.0 0.2642,0.5294 0.2642,0.5294 0.2642,0.5294 0.2642,0.5294
30.0 0.2644,0.5294 0.2639,0.5296 0.2643,0.5294 0.2646,0.5293
C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0
Test Lab: LISUN Test Device: LSG-5000CCD
Test Type: TYPE C Distance: 8.000 m
Temperature: 24.5° Humidity: 60%
Operator: Jacky Inspector:
Lisun Electronics Inc.
http://www.Lisungroup.com
Tel:+86(21)51083341
Fax:+86(21)51083342 Page 25 of 27 Pages
Candlepower Table
GC C0.0 C45.0 C90.0 C135.0 C180.0 C225.0 C270.0 C315.0 C360.0
G0.0 417.8 423.7 420.2 415.6 417.8 423.7 420.2 415.6 417.8
G1.0 418.7 424.6 420.7 414.8 416.6 422.4 419.6 415.9 418.7
G2.0 419.5 425.7 420.7 414.2 415.1 421.1 418.8 415.9 419.5
G3.0 420.2 427.1 421.2 413.2 413.8 419.7 417.9 415.8 420.2
G4.0 421.0 428.1 420.7 412.2 412.4 418.8 416.7 415.4 421.0
G5.0 421.9 428.2 420.5 410.8 410.7 416.9 415.0 414.7 421.9
G6.0 423.5 428.6 420.8 409.3 408.7 414.9 413.1 414.4 423.5
G7.0 423.3 429.1 419.9 407.2 406.4 413.2 411.4 413.2 423.3
G8.0 421.6 429.3 418.8 405.1 404.3 411.0 409.4 411.6 421.6
G9.0 420.9 429.0 417.5 402.8 401.6 408.1 406.9 409.7 420.9
G10.0 420.1 428.6 416.2 400.2 398.4 405.5 404.1 407.9 420.1
G11.0 419.3 427.9 414.5 397.3 395.6 402.0 401.2 405.8 419.3
G12.0 418.1 426.7 412.3 394.1 392.1 398.3 397.7 402.9 418.1
G13.0 416.7 425.2 410.0 391.1 388.6 394.1 394.0 400.1 416.7
G14.0 414.5 422.8 407.0 386.9 384.6 389.4 390.0 396.8 414.5
G15.0 412.1 420.1 403.7 383.1 380.4 384.4 385.2 393.2 412.1
G16.0 409.3 416.9 400.1 378.9 375.8 379.0 380.6 389.5 409.3
G17.0 406.1 412.8 396.2 374.6 371.1 373.5 375.9 385.5 406.1
G18.0 402.4 409.1 392.5 369.8 366.0 367.7 370.5 381.1 402.4
G19.0 398.4 404.2 388.3 365.4 360.7 361.7 364.7 376.5 398.4
G20.0 393.8 399.0 383.1 360.1 355.4 355.9 359.7 371.4 393.8
G21.0 389.1 393.1 378.1 355.0 349.4 349.7 353.9 366.2 389.1
G22.0 383.8 387.7 372.8 349.6 343.2 343.3 348.1 361.4 383.8
G23.0 378.3 381.9 367.6 344.1 337.2 337.5 342.1 355.4 378.3
G24.0 373.1 376.4 361.6 338.7 331.5 331.7 336.4 349.9 373.1
G25.0 367.2 370.3 356.1 332.9 325.2 325.6 330.3 344.1 367.2
G26.0 360.6 364.3 349.9 327.3 319.3 320.1 324.9 338.3 360.6
G27.0 354.6 358.0 344.6 320.8 313.3 314.5 319.0 332.1 354.6
G28.0 348.1 352.1 338.6 315.0 307.1 308.9 313.3 325.7 348.1
G29.0 342.0 346.3 333.1 309.5 301.3 303.3 307.9 319.2 342.0
G30.0 335.5 340.2 327.0 303.6 295.3 298.1 302.7 312.7 335.5
G31.0 329.6 334.4 321.5 297.8 289.7 292.9 297.5 306.5 329.6
G32.0 323.4 329.1 316.2 292.4 284.1 288.1 292.0 300.5 323.4
G33.0 317.8 323.7 310.5 287.0 278.7 283.3 287.1 294.4 317.8
G34.0 312.0 317.9 305.0 281.6 273.2 278.7 282.4 287.9 312.0
G35.0 306.3 312.5 299.8 276.4 267.9 274.6 277.8 282.2 306.3
G36.0 300.7 307.2 294.6 271.1 262.6 270.5 273.2 276.7 300.7
Unit: cd/klm
C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0
Test Lab: LISUN Test Device: LSG-5000CCD
Test Type: TYPE C Distance: 8.000 m
Temperature: 24.5° Humidity: 60%
Operator: Jacky Inspector:
Lisun Electronics Inc.
http://www.Lisungroup.com
Tel:+86(21)51083341
Fax:+86(21)51083342 Page 26 of 27 Pages
Candlepower Table (Continue 1)
GC C0.0 C45.0 C90.0 C135.0 C180.0 C225.0 C270.0 C315.0 C360.0
G37.0 294.9 302.1 289.5 265.8 257.5 266.5 268.7 271.0 294.9
G38.0 289.4 296.6 284.9 260.6 252.6 262.3 264.2 265.6 289.4
G39.0 284.1 291.3 279.9 255.6 249.6 258.6 259.8 259.9 284.1
G40.0 278.8 286.3 274.7 250.7 243.8 254.5 255.2 254.9 278.8
G41.0 273.7 281.2 269.8 245.4 237.9 250.4 250.7 249.1 273.7
G42.0 269.1 276.5 265.3 240.3 232.6 246.3 246.3 244.0 269.1
G43.0 264.1 271.8 262.0 234.9 227.0 241.8 241.5 238.7 264.1
G44.0 259.6 266.9 256.2 229.1 221.7 236.8 236.7 233.3 259.6
G45.0 254.8 262.4 251.6 223.6 216.1 231.4 231.4 227.7 254.8
G46.0 250.1 258.8 246.5 217.6 209.6 225.7 225.7 222.2 250.1
G47.0 245.3 253.6 242.3 211.5 203.6 219.5 220.0 216.4 245.3
G48.0 240.2 249.4 237.6 205.2 196.9 212.6 213.7 210.4 240.2
G49.0 235.3 244.7 233.0 198.3 190.0 205.9 207.0 204.8 235.3
G50.0 229.7 240.2 227.6 191.4 182.8 198.2 200.0 198.0 229.7
G51.0 224.5 235.2 221.8 184.1 175.1 189.9 192.5 190.7 224.5
G52.0 218.6 230.2 216.1 176.4 167.3 181.6 184.6 183.4 218.6
G53.0 212.6 224.4 210.1 168.3 159.0 172.8 176.2 175.7 212.6
G54.0 205.9 218.4 203.1 160.6 151.1 164.0 167.7 168.3 205.9
G55.0 199.1 211.4 196.3 152.0 142.5 154.7 159.1 160.3 199.1
G56.0 191.5 204.0 188.3 143.7 134.1 145.2 150.6 152.2 191.5
G57.0 183.9 196.0 180.4 135.0 125.2 135.8 141.4 143.9 183.9
G58.0 175.7 187.9 171.4 126.6 116.8 127.0 132.8 135.8 175.7
G59.0 166.9 178.7 162.5 117.9 108.7 118.3 123.7 127.8 166.9
G60.0 158.3 169.4 153.1 109.9 101.2 109.5 115.5 119.5 158.3
G61.0 148.7 159.3 143.6 101.6 93.4 101.2 107.0 111.6 148.7
G62.0 139.5 149.3 133.9 93.9 86.6 93.4 99.1 103.8 139.5
G63.0 129.9 138.9 124.3 86.4 79.6 86.1 91.5 96.4 129.9
G64.0 120.7 129.1 114.7 79.9 73.4 79.2 84.6 89.0 120.7
G65.0 111.4 118.9 105.5 73.3 67.7 72.7 77.8 82.5 111.4
G66.0 102.8 109.5 96.6 67.3 62.5 67.2 72.0 76.0 102.8
G67.0 93.9 99.8 88.5 61.9 57.5 61.8 66.1 70.0 93.9
G68.0 86.1 91.4 80.8 56.9 53.0 57.3 61.1 64.5 86.1
G69.0 78.3 83.3 73.3 52.1 49.1 52.8 56.5 59.6 78.3
G70.0 71.4 75.8 67.0 48.2 45.6 49.1 52.1 55.2 71.4
G71.0 64.9 69.1 60.7 44.4 42.4 45.6 48.1 51.2 64.9
G72.0 59.2 62.5 55.5 41.2 39.6 42.4 44.9 47.4 59.2
G73.0 53.9 56.7 50.6 38.0 36.9 39.6 41.8 44.2 53.9
Unit: cd/klm
C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0
Test Lab: LISUN Test Device: LSG-5000CCD
Test Type: TYPE C Distance: 8.000 m
Temperature: 24.5° Humidity: 60%
Operator: Jacky Inspector:
Lisun Electronics Inc.
http://www.Lisungroup.com
Tel:+86(21)51083341
Fax:+86(21)51083342 Page 27 of 27 Pages
Candlepower Table (Continue 2)
GC C0.0 C45.0 C90.0 C135.0 C180.0 C225.0 C270.0 C315.0 C360.0
G74.0 49.4 51.9 46.3 35.2 34.7 37.2 38.9 41.2 49.4
G75.0 45.4 47.4 42.7 32.8 32.7 34.9 36.5 38.6 45.4
G76.0 41.8 43.7 39.3 30.9 30.9 32.9 34.3 36.3 41.8
G77.0 38.5 40.4 36.2 28.9 29.3 31.1 32.3 34.3 38.5
G78.0 35.8 37.4 33.7 27.4 27.8 29.6 30.7 32.3 35.8
G79.0 33.2 34.7 31.3 25.8 26.5 28.2 29.1 30.8 33.2
G80.0 31.1 32.4 29.5 24.4 25.3 26.7 27.7 29.3 31.1
G81.0 29.2 30.6 27.7 23.1 24.2 25.5 26.5 28.0 29.2
G82.0 27.3 28.6 26.1 22.2 22.9 24.5 25.4 26.7 27.3
G83.0 26.0 27.1 24.6 20.9 22.1 23.5 24.5 25.5 26.0
G84.0 24.6 25.7 23.3 20.1 21.4 22.7 23.5 24.6 24.6
G85.0 23.5 24.5 22.2 19.1 20.7 21.7 22.7 23.5 23.5
G86.0 22.6 23.4 21.2 18.3 19.9 20.9 21.9 22.8 22.6
G87.0 21.5 22.3 20.0 17.7 19.4 20.4 21.1 22.0 21.5
G88.0 20.6 21.4 19.2 17.0 18.4 19.6 20.4 21.3 20.6
G89.0 19.9 20.4 18.4 16.4 17.9 19.0 19.8 20.6 19.9
G90.0 19.2 19.7 17.7 15.9 17.4 18.4 19.1 19.9 19.2
Unit: cd/klm
C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0
Test Lab: LISUN Test Device: LSG-5000CCD
Test Type: TYPE C Distance: 8.000 m
Temperature: 24.5° Humidity: 60%
Operator: Jacky Inspector:

More Related Content

PDF
LISUN Moving detector-goniospectroradiometer LSG-5000CCD
PDF
Goniospectroradiometer with-moving-mirror
PDF
Moving Detector Goniophotometer5000
PDF
Moving detector-goniophotometer
PDF
LISUN Moving detector-goniophotometer LSG-5000
PDF
Goniospectroradiometer with-moving-mirror-lsg-2000ccd
PDF
Goniophotometer with-moving-mirror
PDF
LISUN Goniophotometer with-moving-mirror-lsg-2000
LISUN Moving detector-goniospectroradiometer LSG-5000CCD
Goniospectroradiometer with-moving-mirror
Moving Detector Goniophotometer5000
Moving detector-goniophotometer
LISUN Moving detector-goniophotometer LSG-5000
Goniospectroradiometer with-moving-mirror-lsg-2000ccd
Goniophotometer with-moving-mirror
LISUN Goniophotometer with-moving-mirror-lsg-2000

What's hot (12)

PDF
Goniophotometer with Rotating Mirror
PDF
High precision-rotation-luminaire-goniospectroradiometer
PDF
Moving mirror-goniospectroradiometer
PDF
LISUN Near field-type-c-goniophotometer LSG-1900B
PDF
LISUN LSG-1800 goniophotometer
PDF
Goniophotometer for-automotive-and-signal-lamps
PDF
Compact goniophotometer
PDF
High Precision Goniophotometer for Automotive and Traffic Signal Lamps
PDF
Arena vision
PDF
Led lumen-maintenance-and-life-test-system
PDF
Amo incremental _length_encoder_catalog
PDF
Line Lite own branded/made NAV 111 10-watt COB Sharop based retrofit
Goniophotometer with Rotating Mirror
High precision-rotation-luminaire-goniospectroradiometer
Moving mirror-goniospectroradiometer
LISUN Near field-type-c-goniophotometer LSG-1900B
LISUN LSG-1800 goniophotometer
Goniophotometer for-automotive-and-signal-lamps
Compact goniophotometer
High Precision Goniophotometer for Automotive and Traffic Signal Lamps
Arena vision
Led lumen-maintenance-and-life-test-system
Amo incremental _length_encoder_catalog
Line Lite own branded/made NAV 111 10-watt COB Sharop based retrofit
Ad

Similar to Moving detector-goniospectroradiometer (20)

PDF
Goniospectroradiometer with-moving-mirror
PDF
Goniospectroradiometer with-moving-mirror
PDF
Moving detector-goniophotometer
PDF
Moving mirror-goniospectroradiometer
PDF
Moving detector-goniospectroradiometer-lsg-3000ccd
PDF
Moving detector-goniospectroradiometer-lsg-3000ccd
PDF
Moving detector-goniophotometer-lsg-3000
PDF
Moving detector-goniophotometer-lsg-3000
PDF
LISUN Goniospectroradiometer with-moving-mirror LSG-3000CCD
PDF
Moving Detector Goniophotometer
PDF
LISUN Goniophotometer with-moving-mirror-lsg-3000
PDF
LISUN Goniophotometer for Automotive and Signal Lamps Lsg-1950
PDF
LISUN Goniospectroradiometers LSG-1800CCD
PDF
LISUN Goniophotometer for Traffic Signal Lamps LSG-1950S
PDF
Goniospectroradiometers
PDF
Goniospectroradiometers
PDF
Goniophotometer for-automotive-and-signal-lamps
PDF
High precision-rotation-luminaire-goniospectroradiometer
PDF
Rotation Luminaire Goniospectroradiometer
PDF
High precision-rotation-luminaire-goniospectroradiometer
Goniospectroradiometer with-moving-mirror
Goniospectroradiometer with-moving-mirror
Moving detector-goniophotometer
Moving mirror-goniospectroradiometer
Moving detector-goniospectroradiometer-lsg-3000ccd
Moving detector-goniospectroradiometer-lsg-3000ccd
Moving detector-goniophotometer-lsg-3000
Moving detector-goniophotometer-lsg-3000
LISUN Goniospectroradiometer with-moving-mirror LSG-3000CCD
Moving Detector Goniophotometer
LISUN Goniophotometer with-moving-mirror-lsg-3000
LISUN Goniophotometer for Automotive and Signal Lamps Lsg-1950
LISUN Goniospectroradiometers LSG-1800CCD
LISUN Goniophotometer for Traffic Signal Lamps LSG-1950S
Goniospectroradiometers
Goniospectroradiometers
Goniophotometer for-automotive-and-signal-lamps
High precision-rotation-luminaire-goniospectroradiometer
Rotation Luminaire Goniospectroradiometer
High precision-rotation-luminaire-goniospectroradiometer
Ad

More from 世满 江 (20)

PDF
Xenon lamp-aging-test-chamber
PDF
Water pressure-test-apparatus
PDF
Uv aging-test-chamber
PDF
Ul water-spray-test-device
PDF
Thermal resistance-spectroradiometer-system-for-led
PDF
Test corners
PDF
Spectrophotometer
PDF
Spectral colorimeter
PDF
Scientific grade-ccd-spectroradiometer-integrating-sphere-system-9500
PDF
Rohs testing
PDF
Portable ccd-spectroradiometer
PDF
Phosphor relative-brightness-tester 1
PDF
Oxygen bomb
PDF
Optical radiation-safety-test-system
PDF
Near field-type-c-goniophotometer
PDF
Moving detector-goniospectroradiometer
PDF
Lpce 2 lms-9000-buv_ uv-lamp-test-system
PDF
Led power-driver-tester
PDF
Led lumen-maintenance-and-life-test-system
PDF
Led driver-online-tester
Xenon lamp-aging-test-chamber
Water pressure-test-apparatus
Uv aging-test-chamber
Ul water-spray-test-device
Thermal resistance-spectroradiometer-system-for-led
Test corners
Spectrophotometer
Spectral colorimeter
Scientific grade-ccd-spectroradiometer-integrating-sphere-system-9500
Rohs testing
Portable ccd-spectroradiometer
Phosphor relative-brightness-tester 1
Oxygen bomb
Optical radiation-safety-test-system
Near field-type-c-goniophotometer
Moving detector-goniospectroradiometer
Lpce 2 lms-9000-buv_ uv-lamp-test-system
Led power-driver-tester
Led lumen-maintenance-and-life-test-system
Led driver-online-tester

Recently uploaded (20)

PPTX
MicrosoftCybserSecurityReferenceArchitecture-April-2025.pptx
PPTX
Microsoft Excel 365/2024 Beginner's training
PDF
sustainability-14-14877-v2.pddhzftheheeeee
PDF
Two-dimensional Klein-Gordon and Sine-Gordon numerical solutions based on dee...
PDF
Architecture types and enterprise applications.pdf
PDF
Zenith AI: Advanced Artificial Intelligence
PDF
From MVP to Full-Scale Product A Startup’s Software Journey.pdf
PPTX
Benefits of Physical activity for teenagers.pptx
PPTX
The various Industrial Revolutions .pptx
PDF
Enhancing emotion recognition model for a student engagement use case through...
PDF
Flame analysis and combustion estimation using large language and vision assi...
DOCX
search engine optimization ppt fir known well about this
PPT
What is a Computer? Input Devices /output devices
PDF
OpenACC and Open Hackathons Monthly Highlights July 2025
PDF
Hindi spoken digit analysis for native and non-native speakers
PDF
Produktkatalog für HOBO Datenlogger, Wetterstationen, Sensoren, Software und ...
PDF
Hybrid horned lizard optimization algorithm-aquila optimizer for DC motor
PPT
Geologic Time for studying geology for geologist
PPTX
Configure Apache Mutual Authentication
PDF
NewMind AI Weekly Chronicles – August ’25 Week III
MicrosoftCybserSecurityReferenceArchitecture-April-2025.pptx
Microsoft Excel 365/2024 Beginner's training
sustainability-14-14877-v2.pddhzftheheeeee
Two-dimensional Klein-Gordon and Sine-Gordon numerical solutions based on dee...
Architecture types and enterprise applications.pdf
Zenith AI: Advanced Artificial Intelligence
From MVP to Full-Scale Product A Startup’s Software Journey.pdf
Benefits of Physical activity for teenagers.pptx
The various Industrial Revolutions .pptx
Enhancing emotion recognition model for a student engagement use case through...
Flame analysis and combustion estimation using large language and vision assi...
search engine optimization ppt fir known well about this
What is a Computer? Input Devices /output devices
OpenACC and Open Hackathons Monthly Highlights July 2025
Hindi spoken digit analysis for native and non-native speakers
Produktkatalog für HOBO Datenlogger, Wetterstationen, Sensoren, Software und ...
Hybrid horned lizard optimization algorithm-aquila optimizer for DC motor
Geologic Time for studying geology for geologist
Configure Apache Mutual Authentication
NewMind AI Weekly Chronicles – August ’25 Week III

Moving detector-goniospectroradiometer

  • 1. Brochure Global Office of Lisun Electronics Inc. http://www.Lisungroup.com Lisun Group (Hong Kong) Limited Add: Room 803, Chevalier House, 45-51 Chatham Road South, Tsim Sha Tsui, KL, HK Tel: 00852-68852050 Fax: 00852-30785638 Email: SalesHK@Lisungroup.com Lisun Electronics (Shanghai) Co., Ltd Add: 113-114, No. 1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road, Jiading District, Shanghai, 201802, China Tel: +86(21)5108 3341 Fax: +86(21)5108 3342 Email: SalesSH@Lisungroup.com Lisun Electronics Inc. (USA) Add: 445 S. Figueroa Street, Los Angeless, CA 90071, U.S.A. Email: Sales@Lisungroup.com Lisun China Factory Add: NO. 37, Xiangyuan Road, Hangzhou City, Zhejiang Province, China Tel: +86-189-1799-6096 Email: Engineering@Lisungroup.com Leader in Lighting & Electrical Test Instruments Rev. 2/14/2020 Moving Detector Goniospectroradiometer (LSG-5000CCD)
  • 2. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com -Page 1 - 1.System Configuration A. LSG-5000CCD Goniospectroradiometer System:  Goniometric Rotating Console: Japanese Mitsubishi Motor and German Angle encoder System to keep the test accuracy. Both Far Field and Near Field Test.  High Reflective Moving Mirror: Special design and produced to keep high reflective value.  Goniometric Rotating Control Instrument in 19inch cabinet: It connects to the PC and was controlled by the software.  Goniometric Rotating Control Instrument in dark room: This can allow the customer to control the rotating in the dark room when install the lumainires but no need to control in the PC.  Double Channel & High Precision Photometer  Germany produced Class L Constant Temperature Photo Detector  Cross-beam Laser System for Calibrating  English Measuring Software  Automatic Adjust Diaphragm: remote control to adjust the size of diaphragm for the different diameter size luminaries test  Two sets of luminaries Clamps: multi-functions  Oversea Delivery and Packing: all of the instruments and accessories will be packed with Fumigation free three plywood, include the delivery cost to Shanghai sea port B. SLS-150W DC Standard Light Intensity Lamp C. LS2010 Digital Power Meter: High Accuracy to measure AC voltage, current, power and power factor, also measure harmonic D. DC3010 CC & CV DC Power Source: DC3010 output is 30V/10A, Option can be DC6010 (output is 60V/10A) and DC12010 (output is 120V/10A) E. LSP-1KVAR AC Power Source: 1KVA Pure Sine Wave AC Power Source F. CASE-19IN 19inch Standard Instruments Cabinet. G. LMS-9000B High Precision CCD Spectraidomeeter H. CLAMP-9000 Accessories and Adjustable Tripod for LMS-9000B Full View for LSG-5000CCD Moving Detector Goniospectroradiometer Note: PC and Printer prepared by the customer (request at least one USB port)
  • 3. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com -Page 2 - 2. Measurement Principle LSG-5000CCD Moving Detector Goniospectroradiometer is full meet LM-79 Clause 9.3.1 request. The tested lamp will keep burning position and be fixed, near field detector move together with the big mirror in a line, and the far field detector will move with the big mirror synchronously. The detector will always sense the light directly from the luminaries. The rotation priority is determined by the software. If mirror axle is took precedence of rotation, the Goniospectroradiometer will continuously measure the luminous intensity at each γ angle on a vertical plane determined by the C angle, the measuring trace is equivalent to the longitude. Similarly, while the luminaries axle is priority, the system will continuously measure the luminous intensity at each C angle on a conical surface determined by the γ angle, the trace can be looked upon the woof. See the following figure. Measurement Principle 3. System Functions
  • 4. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com -Page 3 - The LSG-5000CCD full meet LM-79 Clause 9.3.1, CIE and GB standards for Goniophotometric of luminaries, this system is used to measure spatial luminous intensity distribution of luminaries for floodlight, street lighting and interior lighting, and other photometric parameters such as spatial iso-intensity curve, intensity distribution curve of each section (shown in rectangular coordinate system or polar coordinate system), iso-illuminance distribution curve, luminance limitation curve, luminaries efficiency, glare grade, effective beam angles, upward luminous flux ratio, downward luminous flux ratio, total luminous flux, effective luminous flux, utilization factor and electric parameters (wattage, power factor, voltage and current) of luminaries etc. LSG-5000 Can test all of the above luminaires 4. Specifications 1) The tested luminaire rotates around the mirror with an angle of (γ)±180°(or 0-360°) and the tested luminaire rotates around itself with an angle of (C)±180°(or 0-360°) 2) The accuracy of angle: 0.05° Resolution of angle: 0.001° 3) Luminosity Testing Range: Illuminance 0.001lx~99,999lx; Light Intensity 1.0cd~107 cd(detector) 4) Accuracy of photometry: Germany produced constant temperature photo detector DIN5032-6/CIE pub1. No. 69 Class L 5) Testing Accuracy: 2%(Under Standard lamp); Stray Light: less than 0.1% 6) Work with high accuracy and quick CCD Spectroradiometer to measure spatial color parameters. 7) Accuracy of chromaticity coordinate: ±0.0015 or ±0.0005(under standard A lamp) 8) Spectral Range Wavelength: 380nm ~780nm; Accuracy of wavelength: ±0.5nm 9) English version software can run in Win7, Win8 or Win10.
  • 5. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com -Page 4 - PS. The LSG-5000XCCD are special size which According to customer’s request 5. Laboratory Requirements 1) Room Requirements according to CIE Model Dark Room (W*H*L) Operation Room(W*L) LSG-5000BCCD 5*5*8~30m 4*4m LSG-5000CCD 4*4*8~30m 4*4m LSG-5000SCCD 4*3*8~30m 4*4m P.S. The LSG-5000XCCD Lab room size will special design  The dark room wall, ceiling and floor should be all coated with dull black paint or be covered by black cloth and black carpet.  Air-conditioner: be set in the dark room to control the temperature around lamps to the standard value upon the CIE requirements. Note: LISUN GROUP engineer dept will submit the Lab Design support documents according to the customer’s real lab size after the formal purchase order was confirmed Model Number LSG-5000B (Big Size) LSG-5000 (Standard Size) LSG-5000S (Standard Size) Measure Size (mm) Diameter=1600 Diameter=1400 Diameter=900 Measure Weight (Kg) 50 40 30 Measure Power(W) 600V/10A,AC/DC 600V/10A,AC/DC 600V/10A,AC/DC
  • 6. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com -Page 5 - Fig: LSG-5000CCD lab dark room view 2) Requirements of Eliminating the stray Light Luminaires must be where the photo detector can only receive the light reflected by the two moving mirror in the LSG-5000 system. The light given off directly by the luminaries and reflected by the wall and floor is warded off by the light fence. Internal surface of the dark room and dark path together with the surface of the light fence should be painted unpolished black or be covered by black cloth and black carpet. 3) Temperature of the Environment Temperature around the lamp or luminaries must be 25℃±1℃ during the test. Exceptions can be given according to relative lamps as following. a. Tungsten Incandescent Lamp: 25℃±5℃ b. Double-caps Fluorescent Lamp: 25℃±1℃ c. High Pressure Mercury Lamp: 25℃±2℃ d. Metal Halogen Lamp: 25℃±2℃
  • 7. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com -Page 6 - e. High Pressure Sodium Lamp: 25℃±2℃ f. Low Pressure Sodium Lamp: 25℃±2 4) Airflow Airflow may be induced by natural aeration, air conditioner or movement of the luminaries in the goniophotometer, but the speed of the airflow couldn’t exceed 0.2m/s. 5) Vibration and shock When the lamp is in lighting, the vibration couldn’t exceed 10m/s2(4 ~ 3000Hz), or the moving scope of the lamp couldn’t exceed 30mm (at most 4Hz) 6) Smoke, Dust and Moisture The test environment must free from smoke, dust or moisture. At the same time, even not during the measurement, smoke, dust or moisture will also influence the reflectance of the reflecting mirror and induce more stray light. So, the test room must be kept clean, no smoke and dry. The humidity should be less than 60% RH. 6. Service 1) Installation and Training LISUN GROUP engineers will take responsibility for installation and Training of the system at the customer’s 2) Period of Guarantee: 24 months The service is for free except technician’s travel payment if the service provided by LISUN GROUP implement at the customer’s. 3) Upgrading the applications software for free 7. Design Standard of Device The construction, technical parameter, test & operate steps as well as data processing software of LSG-5000CCD Moving Detector Goniospectroradiometer meet the following requirements: 3.1 CIE Pub. NO.70,”The Measurement of Absolute Luminous Intensity Distributions” 3.2 CIE DIV.Ⅱ-TC10,”Photometry of Luminaires” 3.3 IES LM-35-1989,”IES Approved Method for Photometric Testing of Floodlights” 3.4 IES LM-31,”IES Approved Method for Photometric Testing of Roadway Luminaires” 3.5 IES-LM-79, “Electrical & Photometric Measurements of Solid-State Lighting Products” 3.6 GB/T 7002-1986,“Luminosity Test of Flood Luminaires”
  • 8. Lisun Electronics Inc. Sales@Lisungroup.com www.Lisungroup.com -Page 7 - 3.7 GB/T 9467-1988, “Luminosity Test of Indoor Luminaires” 3.8 GB/T 9468-1988, “Luminosity Test of Street Luminaires” 3.9 IES 61341 “Method of Measurement of Center Beam Intensity and Beam Angle(s) of Reflector Lamp” 3.10 CIE Pub.NO.76, “Photometry-the CIE System of Physical Photometry” 8. Typical oversea market customers: There are many world famous company and lab institute choose LISUN Goniospecroradiometer, Please get the reference customers’ information from Lisun Group Oversea Sales Dept. 9. Application Software This system can export data files as following formats: This kind of format files can be transferred by other illumination and luminaire design software such as DiaLux Application software can also implement essential calculation for lighting design as iso-illuminance distribution curve on a working plane, luminance limitation curve, luminaire efficiency, effective beam angle, upward luminous flux ratio, downward luminous flux ratio, effective luminous flux, utilization factor curve etc. The Next Page is the Test Report by the software:
  • 9. Lisun Electronics Inc. http://www.Lisungroup.com Tel:+86(21)51083341 Fax:+86(21)51083342 Page 1 of 27 Pages Report No.: LS1711 Test Time: 8/28/2017 17:02 Luminaire Property Luminaire Manufacturer: LISUN Luminaire Category: LED Philips 112 Luminaire Description: LS-71-83-8077 Lamp Catalog: LUMINUS Lamp Description: LUMINUS001 Number of Lamps: 1 Lumens per Lamp: 550 Luminous Length (mm): 50 Luminous Width (mm): 50 Luminous Height (mm): 100 Voltage: 119.9 V Current: 0.530 A Power: 63.55 W Power Factor: 0.999 Photometric Results CIE Class: Direct Total Rated Lamp Lumens: 550.0 lm Measurement Flux: 539.5 lm Efficiency: 98.08% Downward Ratio: 98.08% Upward Ratio: 0.00% Horizontal Diffuse Angle(50%): H99.2 Vertical Diffuse Angle(50%): V101.5 Luminaire Efficacy Rating (LER): 8.54 Central Intensity: 417.76 cd/klm Max. Intensity: 429.28 cd/klm Pos of Max. Intensity: H45 V8 S/MH(C0/C180): 1.14 S/MH(C90/C270): 1.13 Picture Of Luminaire Luminous Intensity Distribution Curve 0 180 9090 1010 170170 2020 160160 3030 150150 4040 140140 5050 130130 6060 120120 7070 110110 8080 100100 536 429 321 214 107 Average Diffuse Angle(50%): 100.1° C0-C180 C90-C270 Unit: cd/klm C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0 Test Lab: LISUN Test Device: LSG-5000CCD Test Type: TYPE C Distance: 8.000 m Temperature: 24.5° Humidity: 60% Operator: Jacky Inspector:
  • 10. Lisun Electronics Inc. http://www.Lisungroup.com Tel:+86(21)51083341 Fax:+86(21)51083342 Page 2 of 27 Pages Luminous Intensity Distribution Curve 0 180 9090 1010 170170 2020 160160 3030 150150 4040 140140 5050 130130 6060 120120 7070 110110 8080 100100 536 429 321 214 107 -180 -120 -60 0 60 120 180 0 107 214 321 429 536 C0-C180 C90-C270 Unit: cd/klm C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0 Test Lab: LISUN Test Device: LSG-5000CCD Test Type: TYPE C Distance: 8.000 m Temperature: 24.5° Humidity: 60% Operator: Jacky Inspector:
  • 11. Lisun Electronics Inc. http://www.Lisungroup.com Tel:+86(21)51083341 Fax:+86(21)51083342 Page 3 of 27 Pages Luminous Intensity Distribution Curve(cd/klm) 0 180 9090 1010 170170 2020 160160 3030 150150 4040 140140 5050 130130 6060 120120 7070 110110 8080 100100 536 429 321 214 107 cd/klm C0-C180 C90-C270 η=98.08% LUMINUS/LUMINUS001 C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0 Test Lab: LISUN Test Device: LSG-5000CCD Test Type: TYPE C Distance: 8.000 m Temperature: 24.5° Humidity: 60% Operator: Jacky Inspector:
  • 12. Lisun Electronics Inc. http://www.Lisungroup.com Tel:+86(21)51083341 Fax:+86(21)51083342 Page 4 of 27 Pages Coefficients Of Utilization - Zonal Cavity Method Curves of Luminaires vs Lighting Area Spacing Criteria (0-180): 1.14 Spacing Criteria (90-270): 1.13 Spacing Criteria (Diagonal): 1.27 RC RW RF = 0.2RCR 0.8 0.8 0.8 0.8 0.7 0.7 0.7 0.7 0.5 0.5 0.5 0.3 0.3 0.3 0.1 0.1 0.1 0 0.7 0.5 0.3 0.1 0.7 0.5 0.3 0.1 0.5 0.3 0.1 0.5 0.3 0.1 0.5 0.3 0.1 0 0 1 2 3 4 5 6 7 8 9 10 117 117 117 117 114 114 114 114 109 109 109 104 104 104 100 100 100 98 107 103 99 95 105 101 97 94 96 93 91 93 90 88 89 87 85 83 98 91 84 79 96 89 83 78 85 80 76 82 78 74 79 76 73 71 90 80 73 67 88 79 72 66 76 70 65 73 68 64 71 66 63 61 83 72 63 57 81 70 63 57 68 61 56 66 60 55 64 59 55 52 76 64 56 50 74 63 55 49 61 54 49 59 53 48 58 52 48 46 71 58 50 44 69 57 49 44 56 48 43 54 48 43 52 47 42 40 66 53 45 39 64 52 44 39 51 44 38 49 43 38 48 42 38 36 61 49 40 35 60 48 40 35 47 40 35 45 39 34 44 38 34 32 57 45 37 32 56 44 37 31 43 36 31 42 36 31 41 35 31 29 54 41 34 29 53 41 34 29 40 33 29 39 33 28 38 32 28 27 10 2 2 3 4 5 6 7 8 910 3 2 3 4 5 6 7 8 910 4 2 3 4 5 6 7 8 10 15 20 25 30 N A(sq.m) Luminous Flux 1000 lm Maintain Factor 0.70 Suspend Length 0.00m Work Height 0.80m Average Lux 100 lx Line Type Reflectivity(%) Ceil Wall Floor 70 50 30 C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0 Test Lab: LISUN Test Device: LSG-5000CCD Test Type: TYPE C Distance: 8.000 m Temperature: 24.5° Humidity: 60% Operator: Jacky Inspector:
  • 13. Lisun Electronics Inc. http://www.Lisungroup.com Tel:+86(21)51083341 Fax:+86(21)51083342 Page 5 of 27 Pages Isocandela (rectangle) 80 60 40 20 0 -20 -40 -60 -80 -80 -60 -40 -20 0 20 40 60 80 Horizontal(Deg) Vertical(Deg) 24 3859 94 149 Imax (100%): 236 cd ( 10%): 24 cd ( 16%): 38 cd ( 25%): 59 cd ( 40%): 94 cd ( 63%): 149 cd (100%): 236 cd C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0 Test Lab: LISUN Test Device: LSG-5000CCD Test Type: TYPE C Distance: 8.000 m Temperature: 24.5° Humidity: 60% Operator: Jacky Inspector:
  • 14. Lisun Electronics Inc. http://www.Lisungroup.com Tel:+86(21)51083341 Fax:+86(21)51083342 Page 6 of 27 Pages Isocandela (sphere) 010 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 270 292.5 315 337.5 0 22.5 45 67.5 90 Pavement Road 24 38 59 94 149 Imax (100%): 236 cd ( 10%): 24 cd ( 16%): 38 cd ( 25%): 59 cd ( 40%): 94 cd ( 63%): 149 cd (100%): 236 cd C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0 Test Lab: LISUN Test Device: LSG-5000CCD Test Type: TYPE C Distance: 8.000 m Temperature: 24.5° Humidity: 60% Operator: Jacky Inspector:
  • 15. Lisun Electronics Inc. http://www.Lisungroup.com Tel:+86(21)51083341 Fax:+86(21)51083342 Page 7 of 27 Pages IsoPPFD Plot 5 4 3 2 1 0 1 2 3 4 5 5 4 3 2 1 0 1 2 3 4 5 Vertical distance / mount height Horizontaldistance/mountheight 0 0 0 0 0 0 Mounting Height: 10.0m Max PPFD(100%): 0.048 umol/s/m^2 ( 1%): 0.000 umol/s/m^2 ( 2%): 0.001 umol/s/m^2 ( 5%): 0.002 umol/s/m^2 ( 10%): 0.005 umol/s/m^2 ( 20%): 0.010 umol/s/m^2 ( 50%): 0.024 umol/s/m^2 (100%): 0.048 umol/s/m^2 C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0 Test Lab: LISUN Test Device: LSG-5000CCD Test Type: TYPE C Distance: 8.000 m Temperature: 24.5° Humidity: 60% Operator: Jacky Inspector:
  • 16. Lisun Electronics Inc. http://www.Lisungroup.com Tel:+86(21)51083341 Fax:+86(21)51083342 Page 8 of 27 Pages Roadway CU Curve 0 10 20 30 40 50 60 70 80 5 4 3 2 1 0 1 2 3 4 5 Pavement Road Street Width / Mounting Height Efficiency(%) Line Type Tilt Angle 0° 5° 10° 15° 20° C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0 Test Lab: LISUN Test Device: LSG-5000CCD Test Type: TYPE C Distance: 8.000 m Temperature: 24.5° Humidity: 60% Operator: Jacky Inspector:
  • 17. Lisun Electronics Inc. http://www.Lisungroup.com Tel:+86(21)51083341 Fax:+86(21)51083342 Page 9 of 27 Pages Lum Limit Curve L(cd/sq.m) G45 G50 G55 G60 G65 G70 G75 G80 G85 C0 C90 C180 C270 26425 23238 19800 15600 10964 7073 4558 3190 2489 26091 23021 19522 15087 10385 6637 4285 3033 2352 22409 18493 14174 9978 6661 4520 3288 2598 2187 24002 20235 15829 11389 7657 5155 3661 2842 2402 Dazzle Quality Illuminance (lx) 1.15 A 2000 1000 500 <=300 1.50 B 2000 1000 500 <=300 1.85 C 2000 1000 500 <=300 2.20 D 2000 1000 500 <=300 2.55 E 2000 1000 500 <=300 a b c d e f g h 6 7 8 9 1000 2 3 4 5 6 7 8 9 10000 2 3 4 85 75 65 55 45 Gamma 8 6 4 3 2 a b c d e f g h a/hs L(cd/sq.m)C90 C270 6 7 8 9 1000 2 3 4 5 6 7 8 9 10000 2 3 4 85 75 65 55 45 Gamma 8 6 4 3 2 a b c d e f g h a/hs L(cd/sq.m)C0 C180 C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0 Test Lab: LISUN Test Device: LSG-5000CCD Test Type: TYPE C Distance: 8.000 m Temperature: 24.5° Humidity: 60% Operator: Jacky Inspector:
  • 18. Lisun Electronics Inc. http://www.Lisungroup.com Tel:+86(21)51083341 Fax:+86(21)51083342 Page 10 of 27 Pages PPFD at a Distance Dist(m) PPFD (umol/s/m^2) Dh/Dv_B(m) S_B(sq.m) PPFDav_B Dh/Dv_F(m) S_F(sq.m) PPFDav_F (umol/s/m^2) 5.0 0.189 11.67/12.21 113.4 0.040 33.62/34.94 947.0 0.002 1.0 4.728 2.33/2.44 4.5 1.004 6.72/6.99 37.9 0.051 2.0 1.182 4.67/4.89 18.1 0.251 13.45/13.98 151.5 0.013 3.0 0.525 7.00/7.33 40.8 0.112 20.17/20.96 340.9 0.006 4.0 0.295 9.33/9.77 72.5 0.063 26.89/27.95 606.1 0.003 Beam Angle(B): H98.8 V101.4 Field Angle(F): H146.9 V148.1 Dh Dv C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0 Test Lab: LISUN Test Device: LSG-5000CCD Test Type: TYPE C Distance: 8.000 m Temperature: 24.5° Humidity: 60% Operator: Jacky Inspector:
  • 19. Lisun Electronics Inc. http://www.Lisungroup.com Tel:+86(21)51083341 Fax:+86(21)51083342 Page 11 of 27 Pages Vertical IsoPPFD Plot 1 2 3 4 5 6 7 8 9 10 11 0 1 2 3 4 5 6 7 8 9 10 Horizontal distance(m) VerticalHeight(m) 0 0 0 0 1 2 Lowest(m): 1.0m Highest(m): 11.000m Max PPFD: 4.7 umol/s/m^2 ( 1%): 0.047 umol/s/m^2 ( 2%): 0.095 umol/s/m^2 ( 5%): 0.236 umol/s/m^2 ( 10%): 0.473 umol/s/m^2 ( 20%): 0.946 umol/s/m^2 ( 50%): 2.364 umol/s/m^2 (100%): 4.728 umol/s/m^2 C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0 Test Lab: LISUN Test Device: LSG-5000CCD Test Type: TYPE C Distance: 8.000 m Temperature: 24.5° Humidity: 60% Operator: Jacky Inspector:
  • 20. Lisun Electronics Inc. http://www.Lisungroup.com Tel:+86(21)51083341 Fax:+86(21)51083342 Page 12 of 27 Pages AreaFluxTable Vertical plane Horizontalplane 00 -10 10 -20 20 -30 30 -40 40 -50 50 -60 60 -70 70 -80 80 -90 90 Flux(T) Flux(E) 00-1010-2020-3030-4040-5050-6060-7070-8080-9090 Flux(T)Flux(E) 0.00.10.20.30.40.50.60.70.70.70.70.60.60.50.40.30.20.1 0.00.20.30.40.60.80.91.11.11.11.11.00.80.70.50.30.20.1 0.10.20.30.60.91.31.72.12.42.42.21.91.41.00.70.40.20.1 0.10.20.40.81.52.43.44.34.74.84.33.62.61.71.00.50.20.1 0.10.20.51.22.33.95.46.46.96.96.45.44.12.81.50.70.30.1 0.10.20.61.63.35.26.77.88.48.47.86.75.33.82.20.90.30.1 0.10.30.82.04.16.07.69.09.910.09.37.96.34.62.71.10.30.1 0.10.30.92.44.56.48.410.211.511.610.79.07.05.13.11.30.40.1 0.10.30.92.54.66.78.911.012.412.511.79.97.55.43.41.40.40.1 0.10.30.92.54.66.78.911.012.412.912.110.07.65.53.51.50.40.1 0.10.30.92.34.46.48.510.411.812.311.59.57.35.33.31.40.40.1 0.10.20.82.04.05.97.69.310.510.810.18.66.85.03.01.20.30.1 0.10.20.61.63.35.16.78.08.99.18.67.66.24.52.51.00.30.1 0.10.20.51.22.33.95.56.77.47.67.36.55.33.61.90.80.30.1 0.10.20.40.81.52.53.74.95.75.95.64.83.72.31.20.60.20.1 0.10.20.30.50.91.32.02.63.13.33.02.61.91.30.80.40.20.1 0.00.20.30.40.60.70.91.11.31.41.31.21.00.70.50.30.20.1 0.00.10.20.30.40.50.60.60.70.70.70.60.60.50.40.30.20.1 1.0 0.0 3.8 0.1 9.9 6.3 23.5 20.4 44.1 41.1 66.3 63.3 88.0 85.2 107.2 104.4 119.7 117.0 122.3 119.7 114.3 111.7 97.3 94.6 76.0 73.3 54.2 51.6 32.6 30.0 14.4 11.7 4.9 1.7 1.1 0.0 7.70.0 11.11.5 19.816.4 36.534.9 55.054.0 69.468.7 81.881.3 92.992.4 99.799.2 100.8100.4 96.295.7 86.485.9 74.473.7 61.060.0 44.042.6 24.521.6 12.13.9 7.40.0 981 932 Unit:lm/klm C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0 Test Lab: LISUN Test Device: LSG-5000CCD Test Type: TYPE C Distance: 8.000 m Temperature: 24.5° Humidity: 60% Operator: Jacky Inspector:
  • 21. Lisun Electronics Inc. http://www.Lisungroup.com Tel:+86(21)51083341 Fax:+86(21)51083342 Page 13 of 27 Pages The Average PPFD Effective Figure Beam Angle:20.0°Height Avg./Nadir. PPFD Diameter / Area 10.0m 0.05/ 3.53m / 9.77sq.m0.047umol/s/m^2 20.0m 0.01/ 7.05m / 39.07sq.m0.012umol/s/m^2 30.0m 0.01/ 10.58m / 87.91sq.m0.005umol/s/m^2 40.0m 0.00/ 14.11m / 156.28sq.m0.003umol/s/m^2 50.0m 0.00/ 17.63m / 244.19sq.m0.002umol/s/m^2 PPF Out: 0.448umol/s C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0 Test Lab: LISUN Test Device: LSG-5000CCD Test Type: TYPE C Distance: 8.000 m Temperature: 24.5° Humidity: 60% Operator: Jacky Inspector:
  • 22. Lisun Electronics Inc. http://www.Lisungroup.com Tel:+86(21)51083341 Fax:+86(21)51083342 Page 14 of 27 Pages UGR Table Reflectance: Room dimensions Ceiling (cavity) Wall Reference plane X=2H Y=2H 3H 4H 6H 8H 12H X=4H Y=2H 3H 4H 6H 8H 12H X=8H Y=4H 6H 8H 12H X=12H Y=4H 6H 8H Viewed crosswise Viewed endwise 0.7 0.5 0.2 0.7 0.5 0.2 0.7 0.3 0.2 0.7 0.3 0.2 0.5 0.5 0.2 0.5 0.5 0.2 0.5 0.3 0.2 0.5 0.3 0.2 0.3 0.3 0.2 0.3 0.3 0.2 22.5 22.123.8 23.422.8 22.424.1 23.624.3 23.9 23.1 22.624.3 23.823.4 22.924.6 24.124.9 24.3 23.3 22.724.4 23.823.6 23.124.7 24.125.0 24.4 23.3 22.824.4 23.823.7 23.124.7 24.125.0 24.5 23.4 22.824.4 23.823.7 23.224.7 24.125.0 24.5 23.4 22.824.3 23.823.8 23.224.7 24.125.0 24.5 22.8 22.423.9 23.523.1 22.724.2 23.824.5 24.1 23.5 23.024.4 24.023.8 23.424.8 24.325.1 24.6 23.7 23.224.5 24.024.1 23.624.9 24.425.2 24.8 23.8 23.324.6 24.124.2 23.724.9 24.525.3 24.9 23.9 23.424.6 24.124.3 23.825.0 24.525.4 24.9 23.9 23.424.6 24.124.4 23.925.0 24.525.4 24.9 23.7 23.224.4 23.924.1 23.724.8 24.325.2 24.7 23.9 23.424.5 24.024.3 23.924.9 24.425.4 24.9 24.0 23.524.5 24.024.5 24.024.9 24.525.4 25.0 24.1 23.724.5 24.124.6 24.225.0 24.625.5 25.1 23.6 23.224.3 23.824.1 23.724.7 24.325.1 24.7 23.9 23.424.4 23.924.4 23.924.8 24.425.3 24.9 24.0 23.624.4 24.024.5 24.124.9 24.525.4 25.0 Variations with the observer position at spacings: S=1.0H +0.2/-0.3 +0.3/-0.5 S=1.5H +0.6/-1.1 +0.8/-1.6 S=2.0H +1.6/-2.7 +1.8/-2.7 Calculate in accordance with CIE Pub.117. The table is revised with 550lm (8log(F/F0) = -2.1). C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0 Test Lab: LISUN Test Device: LSG-5000CCD Test Type: TYPE C Distance: 8.000 m Temperature: 24.5° Humidity: 60% Operator: Jacky Inspector:
  • 23. Lisun Electronics Inc. http://www.Lisungroup.com Tel:+86(21)51083341 Fax:+86(21)51083342 Page 15 of 27 Pages FLUX DISTRIBUTION TABLE BASED ON THE IESNA LUMINAIRE CLASSIFICATION SYSTEM 0° 30°30° 60°60° 80°80° 100°100° 90°90° FRONTBACK FLBL FMBM FHBH FVHBVH UL UL UH ZONE LUMENS % LAMP LUMENS FORWARD LIGHT 279 50.7 FL ( 0°-30°) 86 15.7 FM (30°-60°) 147 26.7 FH (60°-80°) 39 7.1 FVH (80°-90°) 7 1.2 BACK LIGHT 261 47.4 BL ( 0°-30°) 84 15.2 BM (30°-60°) 137 24.9 BH (60°-80°) 34 6.1 BVH (80°-90°) 7 1.2 UP LIGHT 0 0.0 UL (90°-100°) 0 0.0 UH (100°-180°) 0 0.0 TRAPPED LIGHT 11 1.9 BUG(Backlight,Uplight,Glare) Rating Base On TM-15-07 Asymmetrical Luminaire Types (Type I,II,III,IV) B0 U0 G0 Quadrilateral Symmetrical Luminaire Types (Type V,Area Light) B0 U0 G0 C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0 Test Lab: LISUN Test Device: LSG-5000CCD Test Type: TYPE C Distance: 8.000 m Temperature: 24.5° Humidity: 60% Operator: Jacky Inspector:
  • 24. Lisun Electronics Inc. http://www.Lisungroup.com Tel:+86(21)51083341 Fax:+86(21)51083342 Page 16 of 27 Pages LCS Graph 5.3% 10.7% 16.0% 21.3% 26.7% 0° FL 0°-30° 86 lm 15.7% BL 0°-30° 84 lm 15.2% FM 30°-60° 147 lm 26.7% BM 30°-60° 137 lm 24.9% FH 60°-80° 39 lm 7.1% BH 60°-80° 34 lm 6.1% FVH 80°-90° 7 lm 1.2% BVH 80°-90° 7 lm 1.2% UL 90°-100° 0 lm 0.0% UL 90°-100° 0 lm 0.0% UH 100°-180° 0 lm 0.0% Trapped Light:11 lm,1.9% Scale= MAX LCS% Back Light Forward Light C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0 Test Lab: LISUN Test Device: LSG-5000CCD Test Type: TYPE C Distance: 8.000 m Temperature: 24.5° Humidity: 60% Operator: Jacky Inspector:
  • 25. Lisun Electronics Inc. http://www.Lisungroup.com Tel:+86(21)51083341 Fax:+86(21)51083342 Page 17 of 27 Pages Color Properties Chromaticity Coordinate: x=0.4651 y=0.4138 u(u')=0.2645 v=0.3529 v'=0.5293 Correlated Color Temperature: Tc=2653K (duv=0.00074) Measurement Flux: 539.5lm, PAR: 2.189W, PPF: 11.100umol/s Peak Wavelength: 800nm Half Bandwidth: 185.4nm Dominant Wavelength: 584.2nm Color Purity: 0.638 Color Ratio: R=0.269 G=0.704 B=0.027 TM30: Rf=99, Rg=99 Color Render Index: Ra= 99.5 R1 =99.5 R2 =99.5 R3 =99.5 R4 =99.4 R5 =99.3 R6 =99.1 R7 =99.7 R8 =99.6 R9 =98.8 R10=98.8 R11=99.3 R12=98.1 R13=99.4 R14=99.7 R15=99.3 Color Quality Scale: Qa= 96.2 Qf= 98.8 Qp= 98.5 Qg= 96.4 Q1 =96.7 Q2 =97.2 Q3 =97.1 Q4 =96.9 Q5 =96.6 Q6 =96.2 Q7 =95.9 Q8 =95.7 Q9 =95.0 Q10=95.5 Q11=96.0 Q12=96.5 Q13=96.7 Q14=97.2 Q15=0.0 1.2 1.0 0.8 0.6 0.4 0.2 0.0 380 430 480 530 580 630 680 730 780 CIE1931 CHROMATICITY DIAGRAM 0 x y 0.1 .2 0.3 .4 0.5 .6 0.7 .8 C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0 Test Lab: LISUN Test Device: LSG-5000CCD Test Type: TYPE C Distance: 8.000 m Temperature: 24.5° Humidity: 60% Operator: Jacky Inspector:
  • 26. Lisun Electronics Inc. http://www.Lisungroup.com Tel:+86(21)51083341 Fax:+86(21)51083342 Page 18 of 27 Pages Utilisation Factor Table(Floor cavity) Utilisation Factors UF(F) Rating:64W Photometrically tested without ceiling board. Multiply UF values by service correction factors Calculate in accordance with CIBSE Technical Memorandum NO.5 1980 SHR NOM = 1.25 Room Reflectance Ceiling Wall Floor Room Index(RI) 0.75 1.00 1.25 1.50 2.00 2.50 3.00 4.00 5.00 0.70 0.200.50 0.30 0.20 0.50 0.200.50 0.30 0.20 0.30 0.200.50 0.30 0.20 0.00 0.000.00 0.59 0.69 0.76 0.81 0.88 0.92 0.96 1.00 1.02 0.52 0.62 0.70 0.75 0.82 0.87 0.91 0.96 0.99 0.47 0.57 0.64 0.70 0.78 0.83 0.87 0.92 0.96 0.58 0.67 0.74 0.79 0.85 0.89 0.92 0.96 0.98 0.51 0.61 0.68 0.73 0.80 0.85 0.88 0.93 0.95 0.46 0.56 0.64 0.69 0.76 0.81 0.85 0.90 0.93 0.56 0.66 0.72 0.76 0.82 0.86 0.89 0.92 0.94 0.51 0.60 0.67 0.72 0.78 0.82 0.86 0.90 0.92 0.46 0.56 0.63 0.68 0.75 0.79 0.83 0.87 0.90 0.44 0.54 0.60 0.65 0.71 0.76 0.79 0.83 0.86 C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0 Test Lab: LISUN Test Device: LSG-5000CCD Test Type: TYPE C Distance: 8.000 m Temperature: 24.5° Humidity: 60% Operator: Jacky Inspector:
  • 27. Lisun Electronics Inc. http://www.Lisungroup.com Tel:+86(21)51083341 Fax:+86(21)51083342 Page 19 of 27 Pages Utilisation Factor Table(Wall) Utilisation Factors UF(W) Rating:64W Photometrically tested without ceiling board. Multiply UF values by service correction factors Calculate in accordance with CIBSE Technical Memorandum NO.5 1980 SHR NOM = 1.25 Room Reflectance Ceiling Wall Floor Room Index(RI) 0.75 1.00 1.25 1.50 2.00 2.50 3.00 4.00 5.00 0.70 0.200.50 0.30 0.20 0.50 0.200.50 0.30 0.20 0.30 0.200.50 0.30 0.20 0.00 0.000.00 0.92 0.75 0.64 0.55 0.44 0.37 0.31 0.25 0.20 0.77 0.64 0.56 0.49 0.40 0.34 0.29 0.23 0.19 0.66 0.56 0.49 0.44 0.36 0.31 0.27 0.22 0.18 0.89 0.72 0.61 0.53 0.42 0.38 0.30 0.23 0.19 0.75 0.63 0.54 0.47 0.38 0.32 0.28 0.22 0.18 0.65 0.55 0.48 0.43 0.35 0.30 0.26 0.21 0.18 0.86 0.69 0.59 0.51 0.40 0.33 0.29 0.22 0.18 0.74 0.61 0.52 0.46 0.37 0.31 0.27 0.21 0.18 0.65 0.55 0.47 0.42 0.34 0.29 0.25 0.20 0.17 0.54 0.45 0.38 0.33 0.27 0.23 0.19 0.15 0.13 C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0 Test Lab: LISUN Test Device: LSG-5000CCD Test Type: TYPE C Distance: 8.000 m Temperature: 24.5° Humidity: 60% Operator: Jacky Inspector:
  • 28. Lisun Electronics Inc. http://www.Lisungroup.com Tel:+86(21)51083341 Fax:+86(21)51083342 Page 20 of 27 Pages Utilisation Factor Table(Ceiling cavity) Utilisation Factors UF(C) Rating:64W Photometrically tested without ceiling board. Multiply UF values by service correction factors Calculate in accordance with CIBSE Technical Memorandum NO.5 1980 SHR NOM = 1.25 Room Reflectance Ceiling Wall Floor Room Index(RI) 0.75 1.00 1.25 1.50 2.00 2.50 3.00 4.00 5.00 0.70 0.200.50 0.30 0.20 0.50 0.200.50 0.30 0.20 0.30 0.200.50 0.30 0.20 0.00 0.000.00 0.16 0.17 0.18 0.18 0.19 0.20 0.20 0.21 0.21 0.09 0.11 0.12 0.13 0.15 0.16 0.17 0.18 0.19 0.05 0.06 0.08 0.09 0.11 0.13 0.14 0.16 0.17 0.15 0.16 0.17 0.18 0.19 0.19 0.19 0.20 0.20 0.09 0.11 0.12 0.13 0.14 0.15 0.16 0.17 0.18 0.05 0.06 0.08 0.09 0.11 0.12 0.14 0.15 0.16 0.15 0.16 0.16 0.17 0.18 0.18 0.19 0.19 0.19 0.09 0.10 0.12 0.13 0.14 0.15 0.16 0.17 0.18 0.05 0.06 0.08 0.09 0.11 0.12 0.13 0.15 0.16 NA NA NA NA NA NA NA NA NA C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0 Test Lab: LISUN Test Device: LSG-5000CCD Test Type: TYPE C Distance: 8.000 m Temperature: 24.5° Humidity: 60% Operator: Jacky Inspector:
  • 29. Lisun Electronics Inc. http://www.Lisungroup.com Tel:+86(21)51083341 Fax:+86(21)51083342 Page 21 of 27 Pages Zonal Lumen Gamma Imean Zonal Flux Sum Zonal Flux Rel Zonal FluxSum Rel Zonal Flux [°] [cd/klm] [lm] [lm] [%] [%] 0.0-1.0 419.2 0.2 0.2 0.04 0.04 1.0-2.0 419.0 0.7 0.9 0.12 0.16 2.0-3.0 418.8 1.1 2.0 0.20 0.36 3.0-4.0 418.4 1.5 3.5 0.28 0.64 4.0-5.0 417.8 2.0 5.5 0.36 1.00 5.0-6.0 417.0 2.4 7.9 0.44 1.44 6.0-7.0 416.1 2.8 10.8 0.52 1.96 7.0-8.0 414.7 3.3 14.0 0.59 2.55 8.0-9.0 413.0 3.7 17.7 0.67 3.22 9.0-10.0 411.1 4.1 21.8 0.74 3.96 10.0-11.0 409.0 4.5 26.3 0.82 4.78 11.0-12.0 406.6 4.9 31.2 0.89 5.67 12.0-13.0 403.9 5.3 36.4 0.96 6.63 13.0-14.0 400.7 5.6 42.1 1.03 7.65 14.0-15.0 397.1 6.0 48.1 1.09 8.74 15.0-16.0 393.3 6.3 54.4 1.15 9.90 16.0-17.0 389.1 6.7 61.1 1.21 11.11 17.0-18.0 384.7 7.0 68.1 1.27 12.38 18.0-19.0 379.9 7.3 75.3 1.32 13.70 19.0-20.0 374.9 7.5 82.9 1.37 15.07 20.0-21.0 369.6 7.8 90.7 1.42 16.49 21.0-22.0 364.0 8.0 98.7 1.46 17.95 22.0-23.0 358.4 8.3 107.0 1.50 19.46 23.0-24.0 352.7 8.5 115.5 1.54 21.00 24.0-25.0 346.9 8.7 124.2 1.58 22.58 25.0-26.0 341.0 8.9 133.0 1.61 24.19 26.0-27.0 335.1 9.0 142.0 1.64 25.83 27.0-28.0 329.1 9.2 151.2 1.67 27.49 28.0-29.0 323.2 9.3 160.5 1.69 29.18 29.0-30.0 317.4 9.4 169.9 1.71 30.90 30.0-31.0 311.6 9.5 179.5 1.73 32.63 31.0-32.0 306.0 9.6 189.1 1.75 34.39 32.0-33.0 300.5 9.7 198.9 1.77 36.16 33.0-34.0 295.1 9.8 208.7 1.79 37.94 34.0-35.0 289.8 9.9 218.6 1.80 39.74 35.0-36.0 284.6 10.0 228.6 1.81 41.55 C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0 Test Lab: LISUN Test Device: LSG-5000CCD Test Type: TYPE C Distance: 8.000 m Temperature: 24.5° Humidity: 60% Operator: Jacky Inspector:
  • 30. Lisun Electronics Inc. http://www.Lisungroup.com Tel:+86(21)51083341 Fax:+86(21)51083342 Page 22 of 27 Pages Zonal Lumen (Continue 1) Gamma Imean Zonal Flux Sum Zonal Flux Rel Zonal FluxSum Rel Zonal Flux [°] [cd/klm] [lm] [lm] [%] [%] 36.0-37.0 279.5 10.0 238.6 1.82 43.38 37.0-38.0 274.5 10.1 248.7 1.83 45.21 38.0-39.0 269.7 10.1 258.8 1.84 47.05 39.0-40.0 264.9 10.2 268.9 1.85 48.90 40.0-41.0 259.8 10.2 279.1 1.85 50.75 41.0-42.0 254.9 10.2 289.3 1.85 52.60 42.0-43.0 250.1 10.2 299.5 1.85 54.46 43.0-44.0 245.1 10.2 309.7 1.85 56.31 44.0-45.0 240.0 10.1 319.8 1.84 58.15 45.0-46.0 234.7 10.1 329.9 1.84 59.99 46.0-47.0 229.3 10.0 340.0 1.82 61.81 47.0-48.0 223.6 9.9 349.9 1.81 63.62 48.0-49.0 217.8 9.8 359.7 1.79 65.41 49.0-50.0 211.7 9.7 369.4 1.77 67.17 50.0-51.0 205.1 9.5 379.0 1.74 68.91 51.0-52.0 198.2 9.4 388.3 1.70 70.61 52.0-53.0 191.1 9.1 397.5 1.66 72.27 53.0-54.0 183.6 8.9 406.4 1.62 73.89 54.0-55.0 175.9 8.6 415.0 1.57 75.46 55.0-56.0 167.8 8.3 423.4 1.52 76.98 56.0-57.0 159.5 8.0 431.4 1.46 78.43 57.0-58.0 151.0 7.7 439.1 1.40 79.83 58.0-59.0 142.4 7.3 446.4 1.33 81.16 59.0-60.0 133.8 7.0 453.3 1.26 82.43 60.0-61.0 125.2 6.6 459.9 1.19 83.62 61.0-62.0 116.6 6.2 466.1 1.12 84.75 62.0-63.0 108.3 5.8 471.9 1.05 85.80 63.0-64.0 100.2 5.4 477.3 0.98 86.78 64.0-65.0 92.5 5.0 482.3 0.92 87.70 65.0-66.0 85.2 4.7 487.0 0.85 88.55 66.0-67.0 78.3 4.3 491.4 0.79 89.34 67.0-68.0 71.9 4.0 495.4 0.73 90.07 68.0-69.0 66.0 3.7 499.1 0.67 90.74 69.0-70.0 60.6 3.4 502.5 0.62 91.36 70.0-71.0 55.7 3.2 505.6 0.58 91.94 71.0-72.0 51.2 2.9 508.6 0.53 92.47 C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0 Test Lab: LISUN Test Device: LSG-5000CCD Test Type: TYPE C Distance: 8.000 m Temperature: 24.5° Humidity: 60% Operator: Jacky Inspector:
  • 31. Lisun Electronics Inc. http://www.Lisungroup.com Tel:+86(21)51083341 Fax:+86(21)51083342 Page 23 of 27 Pages Zonal Lumen (Continue 2) Gamma Imean Zonal Flux Sum Zonal Flux Rel Zonal FluxSum Rel Zonal Flux [°] [cd/klm] [lm] [lm] [%] [%] 72.0-73.0 47.2 2.7 511.3 0.49 92.96 73.0-74.0 43.5 2.5 513.8 0.46 93.42 74.0-75.0 40.4 2.3 516.2 0.43 93.85 75.0-76.0 37.6 2.2 518.3 0.40 94.25 76.0-77.0 35.1 2.1 520.4 0.37 94.62 77.0-78.0 32.9 1.9 522.3 0.35 94.97 78.0-79.0 30.9 1.8 524.2 0.33 95.30 79.0-80.0 29.1 1.7 525.9 0.31 95.62 80.0-81.0 27.6 1.6 527.5 0.30 95.91 81.0-82.0 26.2 1.6 529.1 0.28 96.20 82.0-83.0 24.9 1.5 530.6 0.27 96.47 83.0-84.0 23.8 1.4 532.0 0.26 96.73 84.0-85.0 22.7 1.4 533.4 0.25 96.98 85.0-86.0 21.8 1.3 534.7 0.24 97.21 86.0-87.0 21.0 1.3 535.9 0.23 97.44 87.0-88.0 20.1 1.2 537.2 0.22 97.66 88.0-89.0 19.4 1.2 538.3 0.21 97.88 89.0-90.0 18.7 1.1 539.5 0.21 98.08 C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0 Test Lab: LISUN Test Device: LSG-5000CCD Test Type: TYPE C Distance: 8.000 m Temperature: 24.5° Humidity: 60% Operator: Jacky Inspector:
  • 32. Lisun Electronics Inc. http://www.Lisungroup.com Tel:+86(21)51083341 Fax:+86(21)51083342 Page 24 of 27 Pages Color Properties Average Color Nonuniformity:∆u'=-0.2642,∆v'=-0.5294,∆u'v'=0.591689 Maximum Color Nonuniformity:∆u'=-0.0004,∆v'=0.0002,∆u'v'=0.000418 Average Color(u',v'):(0.2643,0.5294)Color Distribution Datas: (u',v') GC 0.0 90.0 180.0 270.0 0.0 0.2642,0.5294 0.2642,0.5294 0.2642,0.5294 0.2642,0.5294 30.0 0.2644,0.5294 0.2639,0.5296 0.2643,0.5294 0.2646,0.5293 C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0 Test Lab: LISUN Test Device: LSG-5000CCD Test Type: TYPE C Distance: 8.000 m Temperature: 24.5° Humidity: 60% Operator: Jacky Inspector:
  • 33. Lisun Electronics Inc. http://www.Lisungroup.com Tel:+86(21)51083341 Fax:+86(21)51083342 Page 25 of 27 Pages Candlepower Table GC C0.0 C45.0 C90.0 C135.0 C180.0 C225.0 C270.0 C315.0 C360.0 G0.0 417.8 423.7 420.2 415.6 417.8 423.7 420.2 415.6 417.8 G1.0 418.7 424.6 420.7 414.8 416.6 422.4 419.6 415.9 418.7 G2.0 419.5 425.7 420.7 414.2 415.1 421.1 418.8 415.9 419.5 G3.0 420.2 427.1 421.2 413.2 413.8 419.7 417.9 415.8 420.2 G4.0 421.0 428.1 420.7 412.2 412.4 418.8 416.7 415.4 421.0 G5.0 421.9 428.2 420.5 410.8 410.7 416.9 415.0 414.7 421.9 G6.0 423.5 428.6 420.8 409.3 408.7 414.9 413.1 414.4 423.5 G7.0 423.3 429.1 419.9 407.2 406.4 413.2 411.4 413.2 423.3 G8.0 421.6 429.3 418.8 405.1 404.3 411.0 409.4 411.6 421.6 G9.0 420.9 429.0 417.5 402.8 401.6 408.1 406.9 409.7 420.9 G10.0 420.1 428.6 416.2 400.2 398.4 405.5 404.1 407.9 420.1 G11.0 419.3 427.9 414.5 397.3 395.6 402.0 401.2 405.8 419.3 G12.0 418.1 426.7 412.3 394.1 392.1 398.3 397.7 402.9 418.1 G13.0 416.7 425.2 410.0 391.1 388.6 394.1 394.0 400.1 416.7 G14.0 414.5 422.8 407.0 386.9 384.6 389.4 390.0 396.8 414.5 G15.0 412.1 420.1 403.7 383.1 380.4 384.4 385.2 393.2 412.1 G16.0 409.3 416.9 400.1 378.9 375.8 379.0 380.6 389.5 409.3 G17.0 406.1 412.8 396.2 374.6 371.1 373.5 375.9 385.5 406.1 G18.0 402.4 409.1 392.5 369.8 366.0 367.7 370.5 381.1 402.4 G19.0 398.4 404.2 388.3 365.4 360.7 361.7 364.7 376.5 398.4 G20.0 393.8 399.0 383.1 360.1 355.4 355.9 359.7 371.4 393.8 G21.0 389.1 393.1 378.1 355.0 349.4 349.7 353.9 366.2 389.1 G22.0 383.8 387.7 372.8 349.6 343.2 343.3 348.1 361.4 383.8 G23.0 378.3 381.9 367.6 344.1 337.2 337.5 342.1 355.4 378.3 G24.0 373.1 376.4 361.6 338.7 331.5 331.7 336.4 349.9 373.1 G25.0 367.2 370.3 356.1 332.9 325.2 325.6 330.3 344.1 367.2 G26.0 360.6 364.3 349.9 327.3 319.3 320.1 324.9 338.3 360.6 G27.0 354.6 358.0 344.6 320.8 313.3 314.5 319.0 332.1 354.6 G28.0 348.1 352.1 338.6 315.0 307.1 308.9 313.3 325.7 348.1 G29.0 342.0 346.3 333.1 309.5 301.3 303.3 307.9 319.2 342.0 G30.0 335.5 340.2 327.0 303.6 295.3 298.1 302.7 312.7 335.5 G31.0 329.6 334.4 321.5 297.8 289.7 292.9 297.5 306.5 329.6 G32.0 323.4 329.1 316.2 292.4 284.1 288.1 292.0 300.5 323.4 G33.0 317.8 323.7 310.5 287.0 278.7 283.3 287.1 294.4 317.8 G34.0 312.0 317.9 305.0 281.6 273.2 278.7 282.4 287.9 312.0 G35.0 306.3 312.5 299.8 276.4 267.9 274.6 277.8 282.2 306.3 G36.0 300.7 307.2 294.6 271.1 262.6 270.5 273.2 276.7 300.7 Unit: cd/klm C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0 Test Lab: LISUN Test Device: LSG-5000CCD Test Type: TYPE C Distance: 8.000 m Temperature: 24.5° Humidity: 60% Operator: Jacky Inspector:
  • 34. Lisun Electronics Inc. http://www.Lisungroup.com Tel:+86(21)51083341 Fax:+86(21)51083342 Page 26 of 27 Pages Candlepower Table (Continue 1) GC C0.0 C45.0 C90.0 C135.0 C180.0 C225.0 C270.0 C315.0 C360.0 G37.0 294.9 302.1 289.5 265.8 257.5 266.5 268.7 271.0 294.9 G38.0 289.4 296.6 284.9 260.6 252.6 262.3 264.2 265.6 289.4 G39.0 284.1 291.3 279.9 255.6 249.6 258.6 259.8 259.9 284.1 G40.0 278.8 286.3 274.7 250.7 243.8 254.5 255.2 254.9 278.8 G41.0 273.7 281.2 269.8 245.4 237.9 250.4 250.7 249.1 273.7 G42.0 269.1 276.5 265.3 240.3 232.6 246.3 246.3 244.0 269.1 G43.0 264.1 271.8 262.0 234.9 227.0 241.8 241.5 238.7 264.1 G44.0 259.6 266.9 256.2 229.1 221.7 236.8 236.7 233.3 259.6 G45.0 254.8 262.4 251.6 223.6 216.1 231.4 231.4 227.7 254.8 G46.0 250.1 258.8 246.5 217.6 209.6 225.7 225.7 222.2 250.1 G47.0 245.3 253.6 242.3 211.5 203.6 219.5 220.0 216.4 245.3 G48.0 240.2 249.4 237.6 205.2 196.9 212.6 213.7 210.4 240.2 G49.0 235.3 244.7 233.0 198.3 190.0 205.9 207.0 204.8 235.3 G50.0 229.7 240.2 227.6 191.4 182.8 198.2 200.0 198.0 229.7 G51.0 224.5 235.2 221.8 184.1 175.1 189.9 192.5 190.7 224.5 G52.0 218.6 230.2 216.1 176.4 167.3 181.6 184.6 183.4 218.6 G53.0 212.6 224.4 210.1 168.3 159.0 172.8 176.2 175.7 212.6 G54.0 205.9 218.4 203.1 160.6 151.1 164.0 167.7 168.3 205.9 G55.0 199.1 211.4 196.3 152.0 142.5 154.7 159.1 160.3 199.1 G56.0 191.5 204.0 188.3 143.7 134.1 145.2 150.6 152.2 191.5 G57.0 183.9 196.0 180.4 135.0 125.2 135.8 141.4 143.9 183.9 G58.0 175.7 187.9 171.4 126.6 116.8 127.0 132.8 135.8 175.7 G59.0 166.9 178.7 162.5 117.9 108.7 118.3 123.7 127.8 166.9 G60.0 158.3 169.4 153.1 109.9 101.2 109.5 115.5 119.5 158.3 G61.0 148.7 159.3 143.6 101.6 93.4 101.2 107.0 111.6 148.7 G62.0 139.5 149.3 133.9 93.9 86.6 93.4 99.1 103.8 139.5 G63.0 129.9 138.9 124.3 86.4 79.6 86.1 91.5 96.4 129.9 G64.0 120.7 129.1 114.7 79.9 73.4 79.2 84.6 89.0 120.7 G65.0 111.4 118.9 105.5 73.3 67.7 72.7 77.8 82.5 111.4 G66.0 102.8 109.5 96.6 67.3 62.5 67.2 72.0 76.0 102.8 G67.0 93.9 99.8 88.5 61.9 57.5 61.8 66.1 70.0 93.9 G68.0 86.1 91.4 80.8 56.9 53.0 57.3 61.1 64.5 86.1 G69.0 78.3 83.3 73.3 52.1 49.1 52.8 56.5 59.6 78.3 G70.0 71.4 75.8 67.0 48.2 45.6 49.1 52.1 55.2 71.4 G71.0 64.9 69.1 60.7 44.4 42.4 45.6 48.1 51.2 64.9 G72.0 59.2 62.5 55.5 41.2 39.6 42.4 44.9 47.4 59.2 G73.0 53.9 56.7 50.6 38.0 36.9 39.6 41.8 44.2 53.9 Unit: cd/klm C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0 Test Lab: LISUN Test Device: LSG-5000CCD Test Type: TYPE C Distance: 8.000 m Temperature: 24.5° Humidity: 60% Operator: Jacky Inspector:
  • 35. Lisun Electronics Inc. http://www.Lisungroup.com Tel:+86(21)51083341 Fax:+86(21)51083342 Page 27 of 27 Pages Candlepower Table (Continue 2) GC C0.0 C45.0 C90.0 C135.0 C180.0 C225.0 C270.0 C315.0 C360.0 G74.0 49.4 51.9 46.3 35.2 34.7 37.2 38.9 41.2 49.4 G75.0 45.4 47.4 42.7 32.8 32.7 34.9 36.5 38.6 45.4 G76.0 41.8 43.7 39.3 30.9 30.9 32.9 34.3 36.3 41.8 G77.0 38.5 40.4 36.2 28.9 29.3 31.1 32.3 34.3 38.5 G78.0 35.8 37.4 33.7 27.4 27.8 29.6 30.7 32.3 35.8 G79.0 33.2 34.7 31.3 25.8 26.5 28.2 29.1 30.8 33.2 G80.0 31.1 32.4 29.5 24.4 25.3 26.7 27.7 29.3 31.1 G81.0 29.2 30.6 27.7 23.1 24.2 25.5 26.5 28.0 29.2 G82.0 27.3 28.6 26.1 22.2 22.9 24.5 25.4 26.7 27.3 G83.0 26.0 27.1 24.6 20.9 22.1 23.5 24.5 25.5 26.0 G84.0 24.6 25.7 23.3 20.1 21.4 22.7 23.5 24.6 24.6 G85.0 23.5 24.5 22.2 19.1 20.7 21.7 22.7 23.5 23.5 G86.0 22.6 23.4 21.2 18.3 19.9 20.9 21.9 22.8 22.6 G87.0 21.5 22.3 20.0 17.7 19.4 20.4 21.1 22.0 21.5 G88.0 20.6 21.4 19.2 17.0 18.4 19.6 20.4 21.3 20.6 G89.0 19.9 20.4 18.4 16.4 17.9 19.0 19.8 20.6 19.9 G90.0 19.2 19.7 17.7 15.9 17.4 18.4 19.1 19.9 19.2 Unit: cd/klm C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0 Test Lab: LISUN Test Device: LSG-5000CCD Test Type: TYPE C Distance: 8.000 m Temperature: 24.5° Humidity: 60% Operator: Jacky Inspector: