MV1000/MV2000
Introduction
October 10, 2007
MVAdvanced World Tour
Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 2
Analysis
Analysis “Smart” Analysis
Set-up
Set-up Easy Set-up
Record
Record Reliable Recording
Monitoring
Monitoring Easy-to-Read Display
Top
 Product Concept
 Portable with High Capacity Universal Inputs
 Ideal for Lab and Test Stand Application
 Data Security
Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 3
Outlook
MV2000
10.4-inch TFT
Max. 48 channels
Approx. 5.6 kg
MV1000
5.5-inch TFT
Max. 24 channels
Approx. 3.5 kg
Removable Terminals
Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 4
Analysis
Analysis “Smart” Analysis
Set-up
Set-up Easy Set-up
Record
Record Reliable Recording
Monitoring
Monitoring Easy-to-Read Display
Tier 1:
 Measurement Engine
 Expandability
 Computation Function
 Multifunctional Display
 Networking – Remote Monitoring
Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 5
Measurement Engine
 Fast Sampling (Isolated)
 Universal Analogue Inputs
 ASIC for Accurate Measurement
 Equivalent as 16 bits
 Optional Lineariser function (/CC1)
 High-breakdown-voltage Solid-state Relays
 Minimize TCO: No need to exchange scanner card
MODEL “TURBO” Normal
MV1004, MV1008
MV2008
25 msec 125 msec
MV1006, MV1012, MV1024
MV2010, MV2020, MV2030, MV2040,
MV2048
125 msec 1 sec
ASIC
(Signal Conditioner Chip)
Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 6
Expandability
 Stand-Alone or Expandable
 Stand-Alone Max 24 ch. (MV1000), 48 ch. (MV2000)
 Expandable Support external 300 channels over Modbus
 For Expandable, /M1 and/or /MC1 is required
 Dual Modbus
 Ethernet: Modbus/TCP Client/Server function
 Serial: Modbus RTU Master/Slave function
 Plug-n-Play with MW100
 MW100 as External Input
RS485
MODBUS RTU
kWh, W, A
Reset
Ethernet
MODBUS/TCP
Max 300 ch
Expanded Inputs
Feedback
Math Result
Click to see movie
Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 7
Computation Function (Optional)
 Monitored/Recorded with Analogue Inputs
 Max. 60 ch, 120 character length each
 12 ch: MV1004/1008, MV2008
 24 ch: MV1006/1012/1024
 60 ch: MV2010/2020/2030/2040/2048
 Functions
 Basic arithmetic, relation, logical, TLOG, CLOG
 SQR, ABS, LOG, EXP, LN (Natural logarithms)
 Case Operation: If … then … Else, PRE, RESET, CARRY, HOLD
Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 8
Multifunctional Display – 1
 Max. 36 Display Groups
 MV1000 10 Groups, 6 ch per Group
 MV2000 36 Groups, 10 ch per Group
 Display Update Speed
 Fast Update
 Fast sampling models: 5 sec/div , 10 sec/div (1 div =
40 dots)
 Middle speed models: 15 sec/div@125 msec sampling
 Can change display update speed anytime
 2 Display Speeds Selectable
 Slow speed for normal monitoring,
but faster speed for triggers/alarms
Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 9
Multifunctional Display – 2
Analog Trend Bar Graph Digital Overview Integral Trend
Historical Playback 4-panel Display
(MV2000 only)
Memory Summary Message Summary Alarm Summary
System Info. Error Log Set Menu And more…
Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 10
Networking – Remote Monitoring
 E-mail
 Send mails on Trigger/Alarm/Error
 Immediate Announcement
 Web
 Browse Screen Image from Web Browsers
 Supports Multiple Access
 Can Print Out Screen Image
E-mail
Web
Print Screen with Comment Field
Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 11
Analysis
Analysis “Smart” Analysis
Set-up
Set-up Easy Set-up
Record
Record Reliable Recording
Monitoring
Monitoring Easy-to-Read Display
Tier 2:
 Trigger Modes
 Data Storage
 Dual Removable Media
 Networking – FTP
Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 12
Trigger Mode
 Trigger Source
 Any of Trigger (alarm) setting for any channels
 Specified Trigger (alarm) for a certain channel
 Internal Switch, Remote Input
 Manual key operation
 Timer (Relative, Absolute)
 Above combination shall be programmed in Event-Action function
 Trigger Modes
 Mode: Free, Single, Repeat
 Pre-trigger: 0, 5, 25, 50, 75, 95, or 100 % of file length
Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 13
Data Storage
 Internal Memory: Max 200 M Bytes (Data area)
 Standard: 80 M bytes, Optional: 200 M bytes
 Non-volatile, Effective against Power Failure
 Number of files: Max. 400 (Display data file + Event data file)
 Max file size of one display/event data: 8 M bytes
 Data Format
 Event Data
 Good for fine analysis
 Display Data
 Compressed data
 Pick up Max value and Min value in certain time period
 Good for long-term recording
Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 14
Dual Removable Media
 Dual Removable Media
 Dual Drives: Compact Flash Drive and USB Flash Drive
 Automatic/Manual Copy from Internal Memory
 Supports Max 2 GB
 Support long filename
 Data Format
 Binary / ASCII selectable
 Benefits of Binary Data
 DAQStandard for further analysis
 Can be reloaded on MV-Adv
 Benefits of ASCII Data
 Can open with Spread-sheet Directly
Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 15
Networking – FTP
 FTP Client
 Automatic file transfer to FTP server
 Measurement data
 Manual sample data
 Snapshot
 FTP Server
 Click “Data List” for manual download
 Easy access to data folders:
 internal memory & CF Card
Automatic to Server
Manual Download
Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 16
Analysis
Analysis “Smart” Analysis
Set-up
Set-up Easy Set-up
Record
Record Reliable Recording
Monitoring
Monitoring Easy-to-Read Display
Tier 3:
 “Quick Start” Menu
 Intelligent DAQ
 PC Software “DAQStandard”: Hardware Configurator
Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 17
“Quick Start” Menu
 “Quick Start” Menu
 2 Steps for Simple Set-up
 Range Settings
 Sampling Condition
 Normal Set Menu for Detail Settings
 Decimal Place: Comma, Period
 Temperature Unit: Celsius, Fahrenheit
 Display Language: EN, FR, DE, KR, CH & JP
 USB Keyboard
 USB Keyboard for easy key-entry
 2 USB Interface: Front / Rear 1 each
USB Keyboard
取り直し
“Quick Start” Menu
Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 18
Intelligent DAQ
 Event Action
 Automate Measurement/Recording
 Examples
 Print messages when alarm is detected
 Stop measurement when temperature is saturated
 Generate daily trigger on certain time …
 Report Function(Optional)
 Cycle: Hourly, Daily, Hourly+Daily, Daily+Weekly, Daily+Monthly
 Items: 4 items selectable from Ave/max/Min/Sum/Inst
Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 19
PC Software: DAQStandard Hardware Configurator
 Bundle Software “DAQStandard”
 Configure MV-Adv Online/Offline
 Via TCP/IP, RS-232, RS-422A/485
When USB Flash Drive is inserted
DAQStandard Hardware Configurator
Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 20
Analysis
Analysis “Smart” Analysis
Set-up
Set-up Easy Set-up
Record
Record Reliable Recording
Monitoring
Monitoring Easy-to-Read Display
Tier 4:
 Real-time Analysis
 Quick Historical Playback
 PC Software “DAQStandard”: Historical Viewer
Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 21
Real-time Analysis
 Analysis Tools for Real-time Analysis
 Put Message: 100 Preset Messages, including 10 Free
Messages
 Print Selectable: All Display Groups or a Selected Display Group
 Pause: Freeze Screen
 Measurement works always in Background
 Auto Zone: Avoid over-wraps of waveform
 Fine Grid: Fine-pitch Grid
Message + Fine Grid + Pause
Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 22
Quick Historical Playback
 Two Ways for Historical Playback
 History Key for Easy Access
 Playback the latest data file
 Select Target File from Summery View
 Tools
 Digital values
 Min-Max / Cursor position
 Auto Span
 Adjust Span, Fitting to Screen Width
 Fine Grid
 Put Message
 Overlay order
 Auto Zone
“History” Key
“History” Display
Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 23
PC Software: DAQStandard Viewer
 Bundle Software “DAQStandard”
 Print-out
 Statistics
 File Conversion : Excel, Lotus, CSV
DAQStandard Viewer Print-out Image
Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 24
Thank you for your attention

More Related Content

PDF
Webinar managing instrument obsolence in nuclear edited
PDF
Smartdac+ | Data Acquisition & Control
PPTX
Scada system for real time data monitoring and controlling in industries
PDF
Introduction to lab view 8.6 in 3 hours
PDF
Vm 53 53 A
PDF
Fmu90 ti
PPTX
R&S (rohde-schwarz) SMB100A microwave signal generator
PDF
Prosonic s fmu90 endress+hauser datasheet-transmitter in housing
Webinar managing instrument obsolence in nuclear edited
Smartdac+ | Data Acquisition & Control
Scada system for real time data monitoring and controlling in industries
Introduction to lab view 8.6 in 3 hours
Vm 53 53 A
Fmu90 ti
R&S (rohde-schwarz) SMB100A microwave signal generator
Prosonic s fmu90 endress+hauser datasheet-transmitter in housing

Similar to MV1000-BBBBBBBBBBBB-2000-INTRO-YOKOGAWA.ppt (20)

PDF
6000C Universal input of color paperless recorder
PPTX
Introduction to lab view 8.6 in 3 hours
PDF
Digital productivity is as easy as 1, 2, total insight final
PDF
Yokogawa DX2000 DAQSTATION
PDF
Data Acquisition Equipment for Automation and Process Control
PDF
IRJET- A Survey on Data Acquisition and Remote Monitoring Display
PDF
Identifying noise in daq webinar rp3 171027 (1)
PDF
Scada Supervisory Control And Data Acquisition 3rd Edition 3rd Stuart A Boyer...
PDF
Memograph m rsg 40 endress+hauser datasheet-record, visualize, analyze and co...
PDF
Hardware
PDF
Maintenance Procedures for Yokogawa ADMAG TI Series AXW Magnetic Flow Meter
PDF
Yokogawa Data Acquisition Station DX1000 & DX2000
PPTX
Tektronix mdo3104 mixed domain oscilloscope
PPTX
Unit ii
PPTX
Introduction to National Instrument Data Logging Machine Monitoring and Pow...
PDF
Fundamentals of Oscilloscopes, Version 1.1
PDF
Identifying and Overcoming Noise in Data Acquisition
PDF
Identifying Noise in DAQ
PDF
Mitsubishi power management meters electronic multi measuring instrument-dien...
6000C Universal input of color paperless recorder
Introduction to lab view 8.6 in 3 hours
Digital productivity is as easy as 1, 2, total insight final
Yokogawa DX2000 DAQSTATION
Data Acquisition Equipment for Automation and Process Control
IRJET- A Survey on Data Acquisition and Remote Monitoring Display
Identifying noise in daq webinar rp3 171027 (1)
Scada Supervisory Control And Data Acquisition 3rd Edition 3rd Stuart A Boyer...
Memograph m rsg 40 endress+hauser datasheet-record, visualize, analyze and co...
Hardware
Maintenance Procedures for Yokogawa ADMAG TI Series AXW Magnetic Flow Meter
Yokogawa Data Acquisition Station DX1000 & DX2000
Tektronix mdo3104 mixed domain oscilloscope
Unit ii
Introduction to National Instrument Data Logging Machine Monitoring and Pow...
Fundamentals of Oscilloscopes, Version 1.1
Identifying and Overcoming Noise in Data Acquisition
Identifying Noise in DAQ
Mitsubishi power management meters electronic multi measuring instrument-dien...
Ad

Recently uploaded (20)

PPTX
Presentation 1.pptxnshshdhhdhdhdhdhhdhdhdhd
PPTX
Pin configuration and project related to
PPTX
Clauses_Part1.hshshpjzjxnznxnxnndndndndndndndnndptx
PDF
2_STM32&SecureElements2_STM32&SecureElements
PDF
PakistanCoinageAct-906.pdfdbnsshsjjsbsbb
PPTX
Growth Capital Investment - Espresso Capital.pptx
PPTX
Computers and mobile device: Evaluating options for home and work
PDF
2- Physical Layer (06).pdfgshshshbsbshshshhs
PPTX
rorakshsjppaksvsjsndjdkndjdbdidndjdbdjom.pptx
PDF
20A LG INR18650HJ2 3.6V 2900mAh Battery cells for Power Tools Vacuum Cleaner
PDF
Presented by ATHUL KRISHNA.S_20250813_191657_0000.pdf
PPTX
PLC ANALOGUE DONE BY KISMEC KULIM TD 5 .0
PPTX
A Clear View_ Interpreting Scope Numbers and Features
PDF
GENERATOR AND IMPROVED COIL THEREFOR HAVINGELECTRODYNAMIC PROPERTIES
PPTX
Entre CHtzyshshshshshshshzhhzzhhz 4MSt.pptx
PPTX
Subordinate_Clauses_BlueGradient_Optimized.pptx
PPTX
AI_ML_Internship_WReport_Template_v2.pptx
PDF
Maxon CINEMA 4D 2025 Crack Free Download Latest Version
PDF
Topic-1-Main-Features-of-Data-Processing.pdf
PPTX
ELETRONIC-PRODUCTS-ASSEMBLY-AND-SERVICING-NC-II-WEEK-1-Copy.pptx
Presentation 1.pptxnshshdhhdhdhdhdhhdhdhdhd
Pin configuration and project related to
Clauses_Part1.hshshpjzjxnznxnxnndndndndndndndnndptx
2_STM32&SecureElements2_STM32&SecureElements
PakistanCoinageAct-906.pdfdbnsshsjjsbsbb
Growth Capital Investment - Espresso Capital.pptx
Computers and mobile device: Evaluating options for home and work
2- Physical Layer (06).pdfgshshshbsbshshshhs
rorakshsjppaksvsjsndjdkndjdbdidndjdbdjom.pptx
20A LG INR18650HJ2 3.6V 2900mAh Battery cells for Power Tools Vacuum Cleaner
Presented by ATHUL KRISHNA.S_20250813_191657_0000.pdf
PLC ANALOGUE DONE BY KISMEC KULIM TD 5 .0
A Clear View_ Interpreting Scope Numbers and Features
GENERATOR AND IMPROVED COIL THEREFOR HAVINGELECTRODYNAMIC PROPERTIES
Entre CHtzyshshshshshshshzhhzzhhz 4MSt.pptx
Subordinate_Clauses_BlueGradient_Optimized.pptx
AI_ML_Internship_WReport_Template_v2.pptx
Maxon CINEMA 4D 2025 Crack Free Download Latest Version
Topic-1-Main-Features-of-Data-Processing.pdf
ELETRONIC-PRODUCTS-ASSEMBLY-AND-SERVICING-NC-II-WEEK-1-Copy.pptx
Ad

MV1000-BBBBBBBBBBBB-2000-INTRO-YOKOGAWA.ppt

  • 1. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved MV1000/MV2000 Introduction October 10, 2007 MVAdvanced World Tour
  • 2. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 2 Analysis Analysis “Smart” Analysis Set-up Set-up Easy Set-up Record Record Reliable Recording Monitoring Monitoring Easy-to-Read Display Top  Product Concept  Portable with High Capacity Universal Inputs  Ideal for Lab and Test Stand Application  Data Security
  • 3. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 3 Outlook MV2000 10.4-inch TFT Max. 48 channels Approx. 5.6 kg MV1000 5.5-inch TFT Max. 24 channels Approx. 3.5 kg Removable Terminals
  • 4. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 4 Analysis Analysis “Smart” Analysis Set-up Set-up Easy Set-up Record Record Reliable Recording Monitoring Monitoring Easy-to-Read Display Tier 1:  Measurement Engine  Expandability  Computation Function  Multifunctional Display  Networking – Remote Monitoring
  • 5. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 5 Measurement Engine  Fast Sampling (Isolated)  Universal Analogue Inputs  ASIC for Accurate Measurement  Equivalent as 16 bits  Optional Lineariser function (/CC1)  High-breakdown-voltage Solid-state Relays  Minimize TCO: No need to exchange scanner card MODEL “TURBO” Normal MV1004, MV1008 MV2008 25 msec 125 msec MV1006, MV1012, MV1024 MV2010, MV2020, MV2030, MV2040, MV2048 125 msec 1 sec ASIC (Signal Conditioner Chip)
  • 6. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 6 Expandability  Stand-Alone or Expandable  Stand-Alone Max 24 ch. (MV1000), 48 ch. (MV2000)  Expandable Support external 300 channels over Modbus  For Expandable, /M1 and/or /MC1 is required  Dual Modbus  Ethernet: Modbus/TCP Client/Server function  Serial: Modbus RTU Master/Slave function  Plug-n-Play with MW100  MW100 as External Input RS485 MODBUS RTU kWh, W, A Reset Ethernet MODBUS/TCP Max 300 ch Expanded Inputs Feedback Math Result Click to see movie
  • 7. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 7 Computation Function (Optional)  Monitored/Recorded with Analogue Inputs  Max. 60 ch, 120 character length each  12 ch: MV1004/1008, MV2008  24 ch: MV1006/1012/1024  60 ch: MV2010/2020/2030/2040/2048  Functions  Basic arithmetic, relation, logical, TLOG, CLOG  SQR, ABS, LOG, EXP, LN (Natural logarithms)  Case Operation: If … then … Else, PRE, RESET, CARRY, HOLD
  • 8. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 8 Multifunctional Display – 1  Max. 36 Display Groups  MV1000 10 Groups, 6 ch per Group  MV2000 36 Groups, 10 ch per Group  Display Update Speed  Fast Update  Fast sampling models: 5 sec/div , 10 sec/div (1 div = 40 dots)  Middle speed models: 15 sec/div@125 msec sampling  Can change display update speed anytime  2 Display Speeds Selectable  Slow speed for normal monitoring, but faster speed for triggers/alarms
  • 9. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 9 Multifunctional Display – 2 Analog Trend Bar Graph Digital Overview Integral Trend Historical Playback 4-panel Display (MV2000 only) Memory Summary Message Summary Alarm Summary System Info. Error Log Set Menu And more…
  • 10. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 10 Networking – Remote Monitoring  E-mail  Send mails on Trigger/Alarm/Error  Immediate Announcement  Web  Browse Screen Image from Web Browsers  Supports Multiple Access  Can Print Out Screen Image E-mail Web Print Screen with Comment Field
  • 11. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 11 Analysis Analysis “Smart” Analysis Set-up Set-up Easy Set-up Record Record Reliable Recording Monitoring Monitoring Easy-to-Read Display Tier 2:  Trigger Modes  Data Storage  Dual Removable Media  Networking – FTP
  • 12. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 12 Trigger Mode  Trigger Source  Any of Trigger (alarm) setting for any channels  Specified Trigger (alarm) for a certain channel  Internal Switch, Remote Input  Manual key operation  Timer (Relative, Absolute)  Above combination shall be programmed in Event-Action function  Trigger Modes  Mode: Free, Single, Repeat  Pre-trigger: 0, 5, 25, 50, 75, 95, or 100 % of file length
  • 13. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 13 Data Storage  Internal Memory: Max 200 M Bytes (Data area)  Standard: 80 M bytes, Optional: 200 M bytes  Non-volatile, Effective against Power Failure  Number of files: Max. 400 (Display data file + Event data file)  Max file size of one display/event data: 8 M bytes  Data Format  Event Data  Good for fine analysis  Display Data  Compressed data  Pick up Max value and Min value in certain time period  Good for long-term recording
  • 14. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 14 Dual Removable Media  Dual Removable Media  Dual Drives: Compact Flash Drive and USB Flash Drive  Automatic/Manual Copy from Internal Memory  Supports Max 2 GB  Support long filename  Data Format  Binary / ASCII selectable  Benefits of Binary Data  DAQStandard for further analysis  Can be reloaded on MV-Adv  Benefits of ASCII Data  Can open with Spread-sheet Directly
  • 15. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 15 Networking – FTP  FTP Client  Automatic file transfer to FTP server  Measurement data  Manual sample data  Snapshot  FTP Server  Click “Data List” for manual download  Easy access to data folders:  internal memory & CF Card Automatic to Server Manual Download
  • 16. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 16 Analysis Analysis “Smart” Analysis Set-up Set-up Easy Set-up Record Record Reliable Recording Monitoring Monitoring Easy-to-Read Display Tier 3:  “Quick Start” Menu  Intelligent DAQ  PC Software “DAQStandard”: Hardware Configurator
  • 17. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 17 “Quick Start” Menu  “Quick Start” Menu  2 Steps for Simple Set-up  Range Settings  Sampling Condition  Normal Set Menu for Detail Settings  Decimal Place: Comma, Period  Temperature Unit: Celsius, Fahrenheit  Display Language: EN, FR, DE, KR, CH & JP  USB Keyboard  USB Keyboard for easy key-entry  2 USB Interface: Front / Rear 1 each USB Keyboard 取り直し “Quick Start” Menu
  • 18. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 18 Intelligent DAQ  Event Action  Automate Measurement/Recording  Examples  Print messages when alarm is detected  Stop measurement when temperature is saturated  Generate daily trigger on certain time …  Report Function(Optional)  Cycle: Hourly, Daily, Hourly+Daily, Daily+Weekly, Daily+Monthly  Items: 4 items selectable from Ave/max/Min/Sum/Inst
  • 19. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 19 PC Software: DAQStandard Hardware Configurator  Bundle Software “DAQStandard”  Configure MV-Adv Online/Offline  Via TCP/IP, RS-232, RS-422A/485 When USB Flash Drive is inserted DAQStandard Hardware Configurator
  • 20. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 20 Analysis Analysis “Smart” Analysis Set-up Set-up Easy Set-up Record Record Reliable Recording Monitoring Monitoring Easy-to-Read Display Tier 4:  Real-time Analysis  Quick Historical Playback  PC Software “DAQStandard”: Historical Viewer
  • 21. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 21 Real-time Analysis  Analysis Tools for Real-time Analysis  Put Message: 100 Preset Messages, including 10 Free Messages  Print Selectable: All Display Groups or a Selected Display Group  Pause: Freeze Screen  Measurement works always in Background  Auto Zone: Avoid over-wraps of waveform  Fine Grid: Fine-pitch Grid Message + Fine Grid + Pause
  • 22. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 22 Quick Historical Playback  Two Ways for Historical Playback  History Key for Easy Access  Playback the latest data file  Select Target File from Summery View  Tools  Digital values  Min-Max / Cursor position  Auto Span  Adjust Span, Fitting to Screen Width  Fine Grid  Put Message  Overlay order  Auto Zone “History” Key “History” Display
  • 23. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 23 PC Software: DAQStandard Viewer  Bundle Software “DAQStandard”  Print-out  Statistics  File Conversion : Excel, Lotus, CSV DAQStandard Viewer Print-out Image
  • 24. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 24 Thank you for your attention