Webinar managing instrument obsolence in nuclear edited Smartdac+ | Data Acquisition & Control Scada system for real time data monitoring and controlling in industries Introduction to lab view 8.6 in 3 hours R&S (rohde-schwarz) SMB100A microwave signal generator Prosonic s fmu90 endress+hauser datasheet-transmitter in housing Similar to MV1000-BBBBBBBBBBBB-2000-INTRO-YOKOGAWA.ppt (20)
6000C Universal input of color paperless recorder Introduction to lab view 8.6 in 3 hours Digital productivity is as easy as 1, 2, total insight final Yokogawa DX2000 DAQSTATION Data Acquisition Equipment for Automation and Process Control IRJET- A Survey on Data Acquisition and Remote Monitoring Display Identifying noise in daq webinar rp3 171027 (1) Scada Supervisory Control And Data Acquisition 3rd Edition 3rd Stuart A Boyer... Memograph m rsg 40 endress+hauser datasheet-record, visualize, analyze and co... Maintenance Procedures for Yokogawa ADMAG TI Series AXW Magnetic Flow Meter Yokogawa Data Acquisition Station DX1000 & DX2000 Tektronix mdo3104 mixed domain oscilloscope Introduction to National Instrument Data Logging Machine Monitoring and Pow... Fundamentals of Oscilloscopes, Version 1.1 Identifying and Overcoming Noise in Data Acquisition Mitsubishi power management meters electronic multi measuring instrument-dien... Recently uploaded (20)
Presentation 1.pptxnshshdhhdhdhdhdhhdhdhdhd Pin configuration and project related to Clauses_Part1.hshshpjzjxnznxnxnndndndndndndndnndptx 2_STM32&SecureElements2_STM32&SecureElements PakistanCoinageAct-906.pdfdbnsshsjjsbsbb Growth Capital Investment - Espresso Capital.pptx Computers and mobile device: Evaluating options for home and work 2- Physical Layer (06).pdfgshshshbsbshshshhs rorakshsjppaksvsjsndjdkndjdbdidndjdbdjom.pptx 20A LG INR18650HJ2 3.6V 2900mAh Battery cells for Power Tools Vacuum Cleaner Presented by ATHUL KRISHNA.S_20250813_191657_0000.pdf PLC ANALOGUE DONE BY KISMEC KULIM TD 5 .0 A Clear View_ Interpreting Scope Numbers and Features GENERATOR AND IMPROVED COIL THEREFOR HAVINGELECTRODYNAMIC PROPERTIES Entre CHtzyshshshshshshshzhhzzhhz 4MSt.pptx Subordinate_Clauses_BlueGradient_Optimized.pptx AI_ML_Internship_WReport_Template_v2.pptx Maxon CINEMA 4D 2025 Crack Free Download Latest Version Topic-1-Main-Features-of-Data-Processing.pdf ELETRONIC-PRODUCTS-ASSEMBLY-AND-SERVICING-NC-II-WEEK-1-Copy.pptx MV1000-BBBBBBBBBBBB-2000-INTRO-YOKOGAWA.ppt
- 1. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved
MV1000/MV2000
Introduction
October 10, 2007
MVAdvanced World Tour
- 2. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 2
Analysis
Analysis “Smart” Analysis
Set-up
Set-up Easy Set-up
Record
Record Reliable Recording
Monitoring
Monitoring Easy-to-Read Display
Top
Product Concept
Portable with High Capacity Universal Inputs
Ideal for Lab and Test Stand Application
Data Security
- 3. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 3
Outlook
MV2000
10.4-inch TFT
Max. 48 channels
Approx. 5.6 kg
MV1000
5.5-inch TFT
Max. 24 channels
Approx. 3.5 kg
Removable Terminals
- 4. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 4
Analysis
Analysis “Smart” Analysis
Set-up
Set-up Easy Set-up
Record
Record Reliable Recording
Monitoring
Monitoring Easy-to-Read Display
Tier 1:
Measurement Engine
Expandability
Computation Function
Multifunctional Display
Networking – Remote Monitoring
- 5. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 5
Measurement Engine
Fast Sampling (Isolated)
Universal Analogue Inputs
ASIC for Accurate Measurement
Equivalent as 16 bits
Optional Lineariser function (/CC1)
High-breakdown-voltage Solid-state Relays
Minimize TCO: No need to exchange scanner card
MODEL “TURBO” Normal
MV1004, MV1008
MV2008
25 msec 125 msec
MV1006, MV1012, MV1024
MV2010, MV2020, MV2030, MV2040,
MV2048
125 msec 1 sec
ASIC
(Signal Conditioner Chip)
- 6. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 6
Expandability
Stand-Alone or Expandable
Stand-Alone Max 24 ch. (MV1000), 48 ch. (MV2000)
Expandable Support external 300 channels over Modbus
For Expandable, /M1 and/or /MC1 is required
Dual Modbus
Ethernet: Modbus/TCP Client/Server function
Serial: Modbus RTU Master/Slave function
Plug-n-Play with MW100
MW100 as External Input
RS485
MODBUS RTU
kWh, W, A
Reset
Ethernet
MODBUS/TCP
Max 300 ch
Expanded Inputs
Feedback
Math Result
Click to see movie
- 7. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 7
Computation Function (Optional)
Monitored/Recorded with Analogue Inputs
Max. 60 ch, 120 character length each
12 ch: MV1004/1008, MV2008
24 ch: MV1006/1012/1024
60 ch: MV2010/2020/2030/2040/2048
Functions
Basic arithmetic, relation, logical, TLOG, CLOG
SQR, ABS, LOG, EXP, LN (Natural logarithms)
Case Operation: If … then … Else, PRE, RESET, CARRY, HOLD
- 8. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 8
Multifunctional Display – 1
Max. 36 Display Groups
MV1000 10 Groups, 6 ch per Group
MV2000 36 Groups, 10 ch per Group
Display Update Speed
Fast Update
Fast sampling models: 5 sec/div , 10 sec/div (1 div =
40 dots)
Middle speed models: 15 sec/div@125 msec sampling
Can change display update speed anytime
2 Display Speeds Selectable
Slow speed for normal monitoring,
but faster speed for triggers/alarms
- 9. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 9
Multifunctional Display – 2
Analog Trend Bar Graph Digital Overview Integral Trend
Historical Playback 4-panel Display
(MV2000 only)
Memory Summary Message Summary Alarm Summary
System Info. Error Log Set Menu And more…
- 10. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 10
Networking – Remote Monitoring
E-mail
Send mails on Trigger/Alarm/Error
Immediate Announcement
Web
Browse Screen Image from Web Browsers
Supports Multiple Access
Can Print Out Screen Image
E-mail
Web
Print Screen with Comment Field
- 11. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 11
Analysis
Analysis “Smart” Analysis
Set-up
Set-up Easy Set-up
Record
Record Reliable Recording
Monitoring
Monitoring Easy-to-Read Display
Tier 2:
Trigger Modes
Data Storage
Dual Removable Media
Networking – FTP
- 12. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 12
Trigger Mode
Trigger Source
Any of Trigger (alarm) setting for any channels
Specified Trigger (alarm) for a certain channel
Internal Switch, Remote Input
Manual key operation
Timer (Relative, Absolute)
Above combination shall be programmed in Event-Action function
Trigger Modes
Mode: Free, Single, Repeat
Pre-trigger: 0, 5, 25, 50, 75, 95, or 100 % of file length
- 13. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 13
Data Storage
Internal Memory: Max 200 M Bytes (Data area)
Standard: 80 M bytes, Optional: 200 M bytes
Non-volatile, Effective against Power Failure
Number of files: Max. 400 (Display data file + Event data file)
Max file size of one display/event data: 8 M bytes
Data Format
Event Data
Good for fine analysis
Display Data
Compressed data
Pick up Max value and Min value in certain time period
Good for long-term recording
- 14. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 14
Dual Removable Media
Dual Removable Media
Dual Drives: Compact Flash Drive and USB Flash Drive
Automatic/Manual Copy from Internal Memory
Supports Max 2 GB
Support long filename
Data Format
Binary / ASCII selectable
Benefits of Binary Data
DAQStandard for further analysis
Can be reloaded on MV-Adv
Benefits of ASCII Data
Can open with Spread-sheet Directly
- 15. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 15
Networking – FTP
FTP Client
Automatic file transfer to FTP server
Measurement data
Manual sample data
Snapshot
FTP Server
Click “Data List” for manual download
Easy access to data folders:
internal memory & CF Card
Automatic to Server
Manual Download
- 16. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 16
Analysis
Analysis “Smart” Analysis
Set-up
Set-up Easy Set-up
Record
Record Reliable Recording
Monitoring
Monitoring Easy-to-Read Display
Tier 3:
“Quick Start” Menu
Intelligent DAQ
PC Software “DAQStandard”: Hardware Configurator
- 17. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 17
“Quick Start” Menu
“Quick Start” Menu
2 Steps for Simple Set-up
Range Settings
Sampling Condition
Normal Set Menu for Detail Settings
Decimal Place: Comma, Period
Temperature Unit: Celsius, Fahrenheit
Display Language: EN, FR, DE, KR, CH & JP
USB Keyboard
USB Keyboard for easy key-entry
2 USB Interface: Front / Rear 1 each
USB Keyboard
取り直し
“Quick Start” Menu
- 18. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 18
Intelligent DAQ
Event Action
Automate Measurement/Recording
Examples
Print messages when alarm is detected
Stop measurement when temperature is saturated
Generate daily trigger on certain time …
Report Function(Optional)
Cycle: Hourly, Daily, Hourly+Daily, Daily+Weekly, Daily+Monthly
Items: 4 items selectable from Ave/max/Min/Sum/Inst
- 19. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 19
PC Software: DAQStandard Hardware Configurator
Bundle Software “DAQStandard”
Configure MV-Adv Online/Offline
Via TCP/IP, RS-232, RS-422A/485
When USB Flash Drive is inserted
DAQStandard Hardware Configurator
- 20. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 20
Analysis
Analysis “Smart” Analysis
Set-up
Set-up Easy Set-up
Record
Record Reliable Recording
Monitoring
Monitoring Easy-to-Read Display
Tier 4:
Real-time Analysis
Quick Historical Playback
PC Software “DAQStandard”: Historical Viewer
- 21. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 21
Real-time Analysis
Analysis Tools for Real-time Analysis
Put Message: 100 Preset Messages, including 10 Free
Messages
Print Selectable: All Display Groups or a Selected Display Group
Pause: Freeze Screen
Measurement works always in Background
Auto Zone: Avoid over-wraps of waveform
Fine Grid: Fine-pitch Grid
Message + Fine Grid + Pause
- 22. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 22
Quick Historical Playback
Two Ways for Historical Playback
History Key for Easy Access
Playback the latest data file
Select Target File from Summery View
Tools
Digital values
Min-Max / Cursor position
Auto Span
Adjust Span, Fitting to Screen Width
Fine Grid
Put Message
Overlay order
Auto Zone
“History” Key
“History” Display
- 23. Copyright© 2007 Yokogawa Electric Corporation All Right Reserved 23
PC Software: DAQStandard Viewer
Bundle Software “DAQStandard”
Print-out
Statistics
File Conversion : Excel, Lotus, CSV
DAQStandard Viewer Print-out Image