This document presents the results of a study that used pushover analysis in ETABS to examine the structural performance of irregular RC structures with and without short-leg shear walls. Models of step-shaped, U-shaped, L-shaped, and T-shaped plans were analyzed, with and without short-leg shear walls included. The analysis found that inclusion of short-leg shear walls improved structural performance by increasing the base shear capacity and roof displacement at maximum base shear. Asymmetry in building elevation also decreased structural performance for bare frame models compared to symmetric models. Inclusion of short-leg shear walls was shown to improve performance of irregular structures.