DC TO AC CONVERTER Mohd Shawal Bin Jadin Faculty of Electrical & Electronic Engineering [email_address] BEE4223  Power Electronics & Drives Systems
OVERVIEW Introduction  Principle of operation Performance parameter The half-bridge inverter  Pulse Width Modulation (PWM) PWM Generation PWM Harmonics Current Source Inverter Introduction to three-phase inverter Conclusions
LEARNING OUTCOMES At the end of the lecture, student should be able to: State the operation and characteristics of Inverter.  Discuss the performance parameters and use different technique for analyzing and designing of DC to AC Converter.
INTRODUCTION Inverters are circuits that converts  dc input voltage  to  a symmetric ac output voltage  by which both magnitude and frequency can be controlled. Applications : adjustable speed ac motor drives,  uninterruptible  power supplies (UPS), and ac appliances run from an automobile battery.
TYPES OF INVERTER Voltage Source Inverter (VSI): Current Source Inverter (CSI)
VOLTAGE SOURCE INVERTER (VSI) WITH VARIABLE DC LINK DC link voltage is varied by a DC-to DC converter or controlled rectifier. Generate  “ square wave ”  output voltage. Output voltage  amplitude is varied as  DC link is varied . Frequency  of output voltage is varied by  changing the  frequency of   the square  wave pulses .
VOLTAGE SOURCE INVERTER (VSI) WITH VARIABLE DC LINK Advantages: simple waveform generation Reliable Disadvantages: Extra conversion stage Poor harmonics
VSI WITH FIXED DC LINK DC voltage is held  constant . Output voltage amplitude and frequency are varied  simultaneously using  PWM  technique. Good harmonic control , but at the expense of  complex waveform  generation
SQUARE WAVE INVERTER Square wave inverter can be simplifying justified with a switching scheme of  full bridge converter . An square wave ac output voltage is synthesized from a dc input by  closing and opening the switches in an appropriate sequence . The output voltage can be  +V dc , -V dc , or zero , depending on which switches are closed.
OPERATION OF SIMPLE SQUARE-WAVE INVERTER  Parallel diode is used when the current in the switch is negative Diode will reverse-biased when current is positive in the switch SQUARE-WAVE INVERTERS EQUIVALENT CIRCUIT
WHEN S1-S2 TURN ON & S3-S4 OFF FOR T 1  < T < T 2
WHEN S1-S2 TURN OFF& S3-S4 ON FOR T 2  < T < T 3
PERFORMANCE  PARAMETERS
EXAMPLE A square-wave inverter has a dc source of 125V, an output frequency of 60 Hz, and R-L series load with R = 20 Ohm and L = 20 mH. Determine An expression for load current Rms load current and Average source current
FOURIER SERIES ANALYSIS FOR SQUARE WAVE INVERTER Fourier series method is often the most practical way to analyze load current and to compute power absorbed by load.
FOURIER SERIES ANALYSIS FOR SQUARE WAVE INVERTER The quality of ac output voltage or current can be expressed by total Harmonic Distortion (THD)
EXAMPLE 1 Consider a square wave inverter with V dc =100V, R=10  , L=25mH, and  f =60Hz. Determine Fundamental output voltage THD for output voltage and current and power absorbed by load
EXAMPLE 2 Fundamental output voltage THD v  and THD I
EXAMPLE 2 n f n  (Hz) V n  (V) Z n  (  ) I n  (A) P n  (W) 1 60 127.3 13.7 9.27 429.3 3 180 42.3 30 1.42 10 5 300 25.5 48.2 0.53 1.4 7 420 18.2 66.7 0.27 0.37 9 540 14.1 85.4 0.17 0.14
EXAMPLE 1 (CONT)
AMPLITUDE & HARMONIC CONTROL The  amplitude  of the fundamental frequency for a square-wave output from the full-bridge inverter  is determined by the dc input voltage .  A  controlled output can be produced by modifying the switching scheme .  This output voltage can be controlled by  adjusting the interval    on each side of the pulse where the output is zero. Harmonic also can be eliminated by choosing a value of    which make the sine terms go to zero.
EXAMPLE 2 Design an inverter that will supply the series R-L load of R=10  , L=25mH with a fundamental frequency of 60Hz and current amplitude of 9.27A and THD less than 10%. A variable source is available.
EXAMPLE 2 (CONT) The dominant harmonic current is for n = 3 (third harmonic), so the switching scheme must eliminate the third harmonic.
EXAMPLE 1 (CONT)
EXAMPLE 1 (CONT) n f n  (Hz) V n  (V) Z n  (  ) I n  (A) 1 60 127.3 13.7 9.27 3 180 0 30 0 5 300 25.5 48.2 0.53 7 420 18.2 66.7 0.27 9 540 0 85.4 0
TRY THIS………   –  Ω    α  
PULSE-WIDTH MODULATED OUTPUT  In square wave inverters,  maximum output voltage is achievable . However there in  NO control in harmonics and output voltage magnitude . i.e the  harmonics are always at three, five, seven etc times the fundamental frequency . Hence the  cut-off frequency of the low pass filter is somewhat fixed . The filter size is dictated by the VA ratings of the inverter. To reduce filter size, the PWM switching scheme can be utilized . In this technique,  the harmonics are “pushed” to higher frequencies . Thus the  cut-off frequency of the filter is increased.  Hence the filter components (i.e. L and C) sizes are reduced.  The trade off for this flexibility is  complexity in the switching waveforms .
PULSE WIDTH MODULATION (PWM)
PULSE WIDTH MODULATION (PWM) Triangulation method (Natural sampling) Amplitudes of the triangular wave (carrier) and sine wave (modulating) are compared to obtain PWM waveform. Simple analogue comparator can be used. Basically an analogue method. Its digital version, known as REGULAR sampling is widely used in industry.
PULSE WIDTH MODULATION (PWM) Production of PWM waveform using reference sinewave: Comparator determines instants at which waveforms cross in order to produce switching waveform PWM output waveform tracks amplitude and frequency of reference sinewave
PULSE WIDTH MODULATION (PWM) As switching frequency is increased, switching loss becomes issue Implementation by ICs which essentially contain tables of pre-calculated values of switching angles covering range of output frequencies As computational speeds of ICs increase, it is now possible to calculate required firing angles in real time in order to optimise strategy for harmonic elimination, and control, further improving inverter performance
PULSE WIDTH MODULATION (PWM) TYPES Natural (sinusoidal) sampling  (as shown on previous slide) Problems with analogue circuitry, e.g. Drift, sensitivity etc. Regular sampling  -  simplified version of natural sampling that results in simple digital implementation Optimised PWM  -  PWM waveform are constructed based on certain performance criteria, e.g. THD. Harmonic elimination/minimisation PWM PWM waveforms are constructed to eliminate some undesirable harmonics from the output waveform spectra. Highly mathematical in nature Space-vector modulation (SVM) A simple technique based on volt-second that is normally used with three-phase inverter motordrive
BIPOLAR SWITCHING
UNIPOLAR SWITCHING
PULSE WIDTH MODULATION IN UNIPOLAR INVERTERS The square wave output can be produced using a comparator to compare the triangle wave with the sine wave.
HALF-BRIDGE INVERTER Also known as the “inverter leg”. Basic building block for full bridge, three phase and higher order inverters. G is the “centre point”. Both capacitors have the same value. Thus the DC link is equally “spilt” into two. The top and bottom switch has to be “complementary”, i.e. If the top switch is closed (on), the bottom must be off, and vice-versa.
SHOOT THROUGH FAULT AND“DEAD-TIME” In practical, a dead time as shown below is required to avoid “shoot-through” faults, i.e. short circuit across the DC rail. Dead time creates “low frequency envelope”. Low frequency harmonics emerged. This is the main source of distortion for high-quality sine wave inverter.
INTRODUCTION TO THREE-PHASE INVERTER Each leg (Red, Yellow, Blue) is delayed by 120 degrees. A three-phase inverter with star connected load is shown below
THREE PHASE INVERTER WAVEFORMS
SUMMARY Have examined operation of inverters as means of producing variable-frequency, variable voltage AC source from DC supply PWM provides amplitude control of the fundamental output frequency although the harmonics have large amplitudes, they occur at high frequency and are filtered easily. Considered voltage-sourced and current-sourced inverters which operate from DC supplies which  approximate constant voltage source Introduced pulse-width-modulated inverter

More Related Content

PPT
Project review
PDF
pwm inverter
PDF
Powerelectronics questionbank
PPTX
Inverter
PPT
space vector PWM for 2 leg inverter
PDF
Space vector pwm_inverter
DOC
Document org
PPTX
Four Switch Three Phase Inverter using Space Vector Modulation
Project review
pwm inverter
Powerelectronics questionbank
Inverter
space vector PWM for 2 leg inverter
Space vector pwm_inverter
Document org
Four Switch Three Phase Inverter using Space Vector Modulation

What's hot (20)

PDF
Space Vector Modulation with DC-Link Voltage Balancing Control for Three-Leve...
PDF
A Novel Space Vector Modulation (SVM) Controlled Inverter For Adjustable Spee...
PDF
Space Vector Pulse Width Modulation Schemes for Two-Level Voltage Source Inve...
PPTX
Multi phase Star Rectifier
PDF
Study of sinusoidal and space vector pulse width modulation techniques for a ...
PDF
A Refined Space Vector PWM Signal Generation for Multilevel Inverters
PPTX
SVPWM Inverter
PPT
Series parallel ac rlc networks
PDF
Design Space Vector Modulated PWM Three-Phase Inverter
PDF
Implementation of SVPWM control on FPGA for three phase MATRIX CONVERTER
PDF
Fast svm based 3 phase cascaded five level inverter
PPTX
Power electronics 2
PDF
Balaji mini proj
PPTX
SVM Simulation for three level inverter
PDF
AC AC converters
PDF
Ece320 notes-part1
PPT
Three phase-controlled-rectifiers
PDF
Simplified svpwm algorithm for neutral point clamped 3 level inverter fed dtc...
DOCX
Space Vector Modulation in Voltage Sourced Three Level Neutral Point Clamped ...
Space Vector Modulation with DC-Link Voltage Balancing Control for Three-Leve...
A Novel Space Vector Modulation (SVM) Controlled Inverter For Adjustable Spee...
Space Vector Pulse Width Modulation Schemes for Two-Level Voltage Source Inve...
Multi phase Star Rectifier
Study of sinusoidal and space vector pulse width modulation techniques for a ...
A Refined Space Vector PWM Signal Generation for Multilevel Inverters
SVPWM Inverter
Series parallel ac rlc networks
Design Space Vector Modulated PWM Three-Phase Inverter
Implementation of SVPWM control on FPGA for three phase MATRIX CONVERTER
Fast svm based 3 phase cascaded five level inverter
Power electronics 2
Balaji mini proj
SVM Simulation for three level inverter
AC AC converters
Ece320 notes-part1
Three phase-controlled-rectifiers
Simplified svpwm algorithm for neutral point clamped 3 level inverter fed dtc...
Space Vector Modulation in Voltage Sourced Three Level Neutral Point Clamped ...
Ad

Similar to Powerelectronics Chapter7 090331060223 Phpapp02 (20)

PDF
High power Inverters Introduction & Applications
PPT
power electronics unit 4 eee pe DC to AC
PDF
Lecture slides_Ch 8 power electronics daniel hart.pdf
PDF
Study of Different Types of Inverters and FFT Analysis of Output of SPWM Inve...
PPT
chapter4 DC to AC Converter.ppt
PDF
Efitra1006
PDF
A Comparative Analysis of MPWM & SPWM Techniques to Reduce Harmonic Distortio...
PDF
Manimala2011 r4
PPTX
Inverter
PDF
Design and Simulation of Low Pass Filter for Single phase full bridge Inverte...
PDF
Chapter 4 Inverters.pdf
PPTX
Power Converters for AC drives CH-1.pptx
PDF
Reduction of total harmonic distortion of three-phase inverter using alternat...
PDF
04 PWM-Inverters-Part-3 (CSI & PWM techniques).pdf
PDF
Multilevel Inverter and Multipliers
PDF
An Overview of Different PWM Techniques to Reduce Total Harmonic Distortion o...
PDF
Inverter
PPT
l6-dc to ac converter.ppt
PDF
pulse width modulated inverter techniques
PDF
Some Aspects on 3-Phase Bridge Inverter (180 Degree Mode)
High power Inverters Introduction & Applications
power electronics unit 4 eee pe DC to AC
Lecture slides_Ch 8 power electronics daniel hart.pdf
Study of Different Types of Inverters and FFT Analysis of Output of SPWM Inve...
chapter4 DC to AC Converter.ppt
Efitra1006
A Comparative Analysis of MPWM & SPWM Techniques to Reduce Harmonic Distortio...
Manimala2011 r4
Inverter
Design and Simulation of Low Pass Filter for Single phase full bridge Inverte...
Chapter 4 Inverters.pdf
Power Converters for AC drives CH-1.pptx
Reduction of total harmonic distortion of three-phase inverter using alternat...
04 PWM-Inverters-Part-3 (CSI & PWM techniques).pdf
Multilevel Inverter and Multipliers
An Overview of Different PWM Techniques to Reduce Total Harmonic Distortion o...
Inverter
l6-dc to ac converter.ppt
pulse width modulated inverter techniques
Some Aspects on 3-Phase Bridge Inverter (180 Degree Mode)
Ad

Recently uploaded (20)

PPTX
CkgxkgxydkydyldylydlydyldlyddolydyoyyU2.pptx
PPT
Lecture 3344;;,,(,(((((((((((((((((((((((
PDF
COST SHEET- Tender and Quotation unit 2.pdf
PPT
340036916-American-Literature-Literary-Period-Overview.ppt
PDF
Reconciliation AND MEMORANDUM RECONCILATION
PDF
Solara Labs: Empowering Health through Innovative Nutraceutical Solutions
PPTX
New Microsoft PowerPoint Presentation - Copy.pptx
PDF
Tata consultancy services case study shri Sharda college, basrur
PDF
Power and position in leadershipDOC-20250808-WA0011..pdf
PPTX
Lecture (1)-Introduction.pptx business communication
PDF
Elevate Cleaning Efficiency Using Tallfly Hair Remover Roller Factory Expertise
DOCX
unit 1 COST ACCOUNTING AND COST SHEET
PDF
Outsourced Audit & Assurance in USA Why Globus Finanza is Your Trusted Choice
PDF
NISM Series V-A MFD Workbook v December 2024.khhhjtgvwevoypdnew one must use ...
PDF
Deliverable file - Regulatory guideline analysis.pdf
PDF
Digital Marketing & E-commerce Certificate Glossary.pdf.................
PDF
BsN 7th Sem Course GridNNNNNNNN CCN.pdf
PPTX
HR Introduction Slide (1).pptx on hr intro
PPTX
job Avenue by vinith.pptxvnbvnvnvbnvbnbmnbmbh
PDF
How to Get Business Funding for Small Business Fast
CkgxkgxydkydyldylydlydyldlyddolydyoyyU2.pptx
Lecture 3344;;,,(,(((((((((((((((((((((((
COST SHEET- Tender and Quotation unit 2.pdf
340036916-American-Literature-Literary-Period-Overview.ppt
Reconciliation AND MEMORANDUM RECONCILATION
Solara Labs: Empowering Health through Innovative Nutraceutical Solutions
New Microsoft PowerPoint Presentation - Copy.pptx
Tata consultancy services case study shri Sharda college, basrur
Power and position in leadershipDOC-20250808-WA0011..pdf
Lecture (1)-Introduction.pptx business communication
Elevate Cleaning Efficiency Using Tallfly Hair Remover Roller Factory Expertise
unit 1 COST ACCOUNTING AND COST SHEET
Outsourced Audit & Assurance in USA Why Globus Finanza is Your Trusted Choice
NISM Series V-A MFD Workbook v December 2024.khhhjtgvwevoypdnew one must use ...
Deliverable file - Regulatory guideline analysis.pdf
Digital Marketing & E-commerce Certificate Glossary.pdf.................
BsN 7th Sem Course GridNNNNNNNN CCN.pdf
HR Introduction Slide (1).pptx on hr intro
job Avenue by vinith.pptxvnbvnvnvbnvbnbmnbmbh
How to Get Business Funding for Small Business Fast

Powerelectronics Chapter7 090331060223 Phpapp02

  • 1. DC TO AC CONVERTER Mohd Shawal Bin Jadin Faculty of Electrical & Electronic Engineering [email_address] BEE4223 Power Electronics & Drives Systems
  • 2. OVERVIEW Introduction Principle of operation Performance parameter The half-bridge inverter Pulse Width Modulation (PWM) PWM Generation PWM Harmonics Current Source Inverter Introduction to three-phase inverter Conclusions
  • 3. LEARNING OUTCOMES At the end of the lecture, student should be able to: State the operation and characteristics of Inverter. Discuss the performance parameters and use different technique for analyzing and designing of DC to AC Converter.
  • 4. INTRODUCTION Inverters are circuits that converts dc input voltage to a symmetric ac output voltage by which both magnitude and frequency can be controlled. Applications : adjustable speed ac motor drives, uninterruptible power supplies (UPS), and ac appliances run from an automobile battery.
  • 5. TYPES OF INVERTER Voltage Source Inverter (VSI): Current Source Inverter (CSI)
  • 6. VOLTAGE SOURCE INVERTER (VSI) WITH VARIABLE DC LINK DC link voltage is varied by a DC-to DC converter or controlled rectifier. Generate “ square wave ” output voltage. Output voltage amplitude is varied as DC link is varied . Frequency of output voltage is varied by changing the frequency of the square wave pulses .
  • 7. VOLTAGE SOURCE INVERTER (VSI) WITH VARIABLE DC LINK Advantages: simple waveform generation Reliable Disadvantages: Extra conversion stage Poor harmonics
  • 8. VSI WITH FIXED DC LINK DC voltage is held constant . Output voltage amplitude and frequency are varied simultaneously using PWM technique. Good harmonic control , but at the expense of complex waveform generation
  • 9. SQUARE WAVE INVERTER Square wave inverter can be simplifying justified with a switching scheme of full bridge converter . An square wave ac output voltage is synthesized from a dc input by closing and opening the switches in an appropriate sequence . The output voltage can be +V dc , -V dc , or zero , depending on which switches are closed.
  • 10. OPERATION OF SIMPLE SQUARE-WAVE INVERTER Parallel diode is used when the current in the switch is negative Diode will reverse-biased when current is positive in the switch SQUARE-WAVE INVERTERS EQUIVALENT CIRCUIT
  • 11. WHEN S1-S2 TURN ON & S3-S4 OFF FOR T 1 < T < T 2
  • 12. WHEN S1-S2 TURN OFF& S3-S4 ON FOR T 2 < T < T 3
  • 14. EXAMPLE A square-wave inverter has a dc source of 125V, an output frequency of 60 Hz, and R-L series load with R = 20 Ohm and L = 20 mH. Determine An expression for load current Rms load current and Average source current
  • 15. FOURIER SERIES ANALYSIS FOR SQUARE WAVE INVERTER Fourier series method is often the most practical way to analyze load current and to compute power absorbed by load.
  • 16. FOURIER SERIES ANALYSIS FOR SQUARE WAVE INVERTER The quality of ac output voltage or current can be expressed by total Harmonic Distortion (THD)
  • 17. EXAMPLE 1 Consider a square wave inverter with V dc =100V, R=10  , L=25mH, and f =60Hz. Determine Fundamental output voltage THD for output voltage and current and power absorbed by load
  • 18. EXAMPLE 2 Fundamental output voltage THD v and THD I
  • 19. EXAMPLE 2 n f n (Hz) V n (V) Z n (  ) I n (A) P n (W) 1 60 127.3 13.7 9.27 429.3 3 180 42.3 30 1.42 10 5 300 25.5 48.2 0.53 1.4 7 420 18.2 66.7 0.27 0.37 9 540 14.1 85.4 0.17 0.14
  • 21. AMPLITUDE & HARMONIC CONTROL The amplitude of the fundamental frequency for a square-wave output from the full-bridge inverter is determined by the dc input voltage . A controlled output can be produced by modifying the switching scheme . This output voltage can be controlled by adjusting the interval  on each side of the pulse where the output is zero. Harmonic also can be eliminated by choosing a value of  which make the sine terms go to zero.
  • 22. EXAMPLE 2 Design an inverter that will supply the series R-L load of R=10  , L=25mH with a fundamental frequency of 60Hz and current amplitude of 9.27A and THD less than 10%. A variable source is available.
  • 23. EXAMPLE 2 (CONT) The dominant harmonic current is for n = 3 (third harmonic), so the switching scheme must eliminate the third harmonic.
  • 25. EXAMPLE 1 (CONT) n f n (Hz) V n (V) Z n (  ) I n (A) 1 60 127.3 13.7 9.27 3 180 0 30 0 5 300 25.5 48.2 0.53 7 420 18.2 66.7 0.27 9 540 0 85.4 0
  • 26. TRY THIS………   –  Ω    α  
  • 27. PULSE-WIDTH MODULATED OUTPUT In square wave inverters, maximum output voltage is achievable . However there in NO control in harmonics and output voltage magnitude . i.e the harmonics are always at three, five, seven etc times the fundamental frequency . Hence the cut-off frequency of the low pass filter is somewhat fixed . The filter size is dictated by the VA ratings of the inverter. To reduce filter size, the PWM switching scheme can be utilized . In this technique, the harmonics are “pushed” to higher frequencies . Thus the cut-off frequency of the filter is increased. Hence the filter components (i.e. L and C) sizes are reduced. The trade off for this flexibility is complexity in the switching waveforms .
  • 29. PULSE WIDTH MODULATION (PWM) Triangulation method (Natural sampling) Amplitudes of the triangular wave (carrier) and sine wave (modulating) are compared to obtain PWM waveform. Simple analogue comparator can be used. Basically an analogue method. Its digital version, known as REGULAR sampling is widely used in industry.
  • 30. PULSE WIDTH MODULATION (PWM) Production of PWM waveform using reference sinewave: Comparator determines instants at which waveforms cross in order to produce switching waveform PWM output waveform tracks amplitude and frequency of reference sinewave
  • 31. PULSE WIDTH MODULATION (PWM) As switching frequency is increased, switching loss becomes issue Implementation by ICs which essentially contain tables of pre-calculated values of switching angles covering range of output frequencies As computational speeds of ICs increase, it is now possible to calculate required firing angles in real time in order to optimise strategy for harmonic elimination, and control, further improving inverter performance
  • 32. PULSE WIDTH MODULATION (PWM) TYPES Natural (sinusoidal) sampling (as shown on previous slide) Problems with analogue circuitry, e.g. Drift, sensitivity etc. Regular sampling - simplified version of natural sampling that results in simple digital implementation Optimised PWM - PWM waveform are constructed based on certain performance criteria, e.g. THD. Harmonic elimination/minimisation PWM PWM waveforms are constructed to eliminate some undesirable harmonics from the output waveform spectra. Highly mathematical in nature Space-vector modulation (SVM) A simple technique based on volt-second that is normally used with three-phase inverter motordrive
  • 35. PULSE WIDTH MODULATION IN UNIPOLAR INVERTERS The square wave output can be produced using a comparator to compare the triangle wave with the sine wave.
  • 36. HALF-BRIDGE INVERTER Also known as the “inverter leg”. Basic building block for full bridge, three phase and higher order inverters. G is the “centre point”. Both capacitors have the same value. Thus the DC link is equally “spilt” into two. The top and bottom switch has to be “complementary”, i.e. If the top switch is closed (on), the bottom must be off, and vice-versa.
  • 37. SHOOT THROUGH FAULT AND“DEAD-TIME” In practical, a dead time as shown below is required to avoid “shoot-through” faults, i.e. short circuit across the DC rail. Dead time creates “low frequency envelope”. Low frequency harmonics emerged. This is the main source of distortion for high-quality sine wave inverter.
  • 38. INTRODUCTION TO THREE-PHASE INVERTER Each leg (Red, Yellow, Blue) is delayed by 120 degrees. A three-phase inverter with star connected load is shown below
  • 39. THREE PHASE INVERTER WAVEFORMS
  • 40. SUMMARY Have examined operation of inverters as means of producing variable-frequency, variable voltage AC source from DC supply PWM provides amplitude control of the fundamental output frequency although the harmonics have large amplitudes, they occur at high frequency and are filtered easily. Considered voltage-sourced and current-sourced inverters which operate from DC supplies which approximate constant voltage source Introduced pulse-width-modulated inverter