SlideShare a Scribd company logo
2
Most read
SEMTECH®
-DSOn Board, In-Use Emissions Analyzer
Sinceit’sintroductionin2002,Sensors’SEMTECH-DShassetthestandardfor
Portable Emissions Measurement Systems (PEMS). Capable of monitoring
the raw exhaust from both spark ignition and compression ignition engines,
the DS measures CO, CO2, O2, NO, NO2 and THC, ensuring compliance
with EPA’s CFR 1065. Sensors works closely with environmental regulatory
agencies and engine manufacturers throughout the world, ensuring that
the DS continues to define and raise the global standards for in-use vehicle
emissions measurement solutions.
The DS comes complete with SENSOR Tech-PC, a powerful emissions
software package, primarily intended for controlling the SEMTECH-DS
and performing emissions calculations. Built-in flexibility with both digital
and analog I/Os enables the user to interface with a number of auxiliary
devices, and to set up the system in accordance with specific application
needs. A wireless Ethernet connection can be used for communications
between SENSOR Tech-PC and the SEMTECH-DS.
Emissions
Measurement
Solutions
2
SEMTECH-DS
On Board, In-Use Emissions Analyzer
System Features and Benefits
Heated FID Sampling: The exhaust sample is maintained at 191°C,
using a heated sample line, filter and pump, so as to minimize the loss
of hydrocarbons prior to entering the FID chamber for analysis.
Sample Conditioning: A compact sample conditioning system is
completely contained within the unit, minimizing contamination of the
analyzers.
NO and NO2 measurement: Proprietary NDUV measures NO and NO2
separately and simultaneously.
Pressure Compensation: Sample pumps operate at constant volume,
regardless of ambient pressure, ensuring that transport times are
independent of altitude.
Calibration Utilities: Easy setup and interface to zero calibrate, span
and audit all gases, perform leak tests and purge the system.
Test Setup Utility: Offers the user maximum control over test
parameters, detection levels and calculation limits.
PostProcessor:Timealignsdataandcalculatesrealtimemassemissions,
raw emission concentrations and fuel economy.
Weather Probe: Actual weather information is required for precise
humidity compensation.
Shock Resistant Design: Meets MIL-STD 810F for shock and vibration.
Sample Installations
Span Screen of SENSOR Tech-PC
Heavy Duty Truck
Excavator
Passenger Car
Snowmobile
3
SEMTECH-DS
On Board, In-Use Emissions Analyzer
Optional Accessories
Heated Sample Line: Various length lines are available, which
maintain the exhaust at 191°C.
Global Positioning System: Overlay emissions data with route
and elevation information.
Vehicle Interface: Heavy duty SAE modules and light duty OBD-II
modulesareavailable.VehicleECMparametersarerecordedwith
the emissions data, with support for 10 different protocols.
Environmental Enclosure: Protects the system in harsh
environments.
Event Marker: Mark start and end points for events with a digital
trigger.
Auxiliary Break-Out Box: Connect an external RPM probe or
other digital inputs to the DS, with data that is time aligned with
the emissions measurements.
Analog I/O Break-out Box: Customize DAC data with up to 3
analog inputs, and 8 analog outputs with a 0-10V range.
Power Supply: A 12VDC supply with either 120VAC or 220VAC
input is available, either as a rack mount or a portable unit.
Power Splitter Cable: For Heavy Duty 12VDC, this cable allows
the simultaneous connection of DS, PPMD, power supply and
battery.
SENSOR Tech-CT: Post processing application providing in-use
compliance test reports, formatted for EPA submission.
SENSOR Tech-PC
While collecting emissions test data, the user can
monitor the system directly from the application
software. System status information includes:
System flow diagram, with real time temperatures•	
and pressures throughout the unit.
System flags and warnings, for any parameter that•	
is out of normal range.
Real time emissions data display, in tabular and•	
graphical formats.
In addition to the graphing capabilities within SENSOR
Tech-PC’s post processor, data is exported into csv
format, for easy graphing and reporting. SENSOR Tech-
CT post processing software is also available, providing
in-use emissions compliance reports in the proper
format to upload to the EPA’s Verify (CDX) web site.
User Support
As with all SEMTECH products, the DS comes with a
wide range of customer support. Sensors’ Remote
Support, powered by WebEx, enables our trained
technicians to view your SEMTECH unit in real-time,
to help answer your questions, diagnose issues,
and evaluate data, without requiring any additional
software. The SEMTECH Users’ Network, SUN, has a
forum for users to share insights on best practices for
in-use emissions testing, and to stay up to date with
the latest software releases.
Graphing Feature within the SENSOR Tech-PC Post Processor
System Flow Diagram
Sensors, Inc. • 6812 State Rd. • Saline, Michigan 48176 • PH:(734) 429-2100 • FX:(734) 429-4080 • www.sensors-inc.com
Sensors Europe GmbH • Feldheider Str. 60 • 40699 Erkrath • Germany • PH: +49 (0) 2104-14188-0 • FX: +49 (0) 2104-14188-14
SEMTECH-DS System Specifications
Gas CO CO2 NO NO2 THC
Range 0 - 8% 0 - 20%
0 - 2,500
ppm
0 - 500 ppm
0 - 100
ppmC
0 - 1,000
ppmC
0 - 10,000
ppmC
0 - 40,000
ppmC
Resolution 10 ppm 0.01% 1 ppm 1 ppm 0.1 ppmC 1 ppmC 1 ppmC 10 ppmC
Accuracy
±3% of
reading or
± 50 ppm
±3% of
reading or
± 0.1%
±3% of
reading or
± 15 ppm
±3% of
reading or
± 10 ppm
±2.0 % of
reading or
±5 ppmC
±2.0 % of
reading or
±5 ppmC
±2.0 % of
reading or
±25 ppmC
±2.0 % of
reading or
±100 ppmC
Linearity
Intercept ≤0.5 % of range
0.990 ≤Slope ≤1.01
SEE ≤1.0 % of range
r2
≥0.998
Intercept
≤1.0 % of
range
0.985≤Slope
≤1.015
SEE ≤1.0 %
of range
r2
≥0.998
Intercept ≤0.5 % of range
0.990 ≤Slope ≤1.01
SEE ≤1.0 % of range
r2
≥0.998
Repeatability
±2 % of
reading or
20 ppm
±2 % of
reading or
±0.05 %
±2 % of
reading or
5 ppm
±2 % of
reading or
5 ppm
±1.0 % of
reading or
±2 ppmC
±1.0 % of
reading or
±2 ppmC
±1.0 % of
reading or
±10 ppmC
±1.0 % of
reading or
±40 ppmC
Noise ±20 ppm ±0.02% ± 2 ppm ± 2 ppm ± 2 ppmC ± 2 ppmC ± 10 ppmC ± 40 ppmC
Span Drift
±2 % of
reading or
20 ppm
±2 % of
reading or
0.1 %
±2 % of
reading or
20 ppm
± 10 ppm
±1.0 % of
reading or
3 ppmC
±1.0 % of
reading or
3 ppmC
±1.0 % of
reading or
15 ppmC
±1.0 % of
reading or
60 ppmC
Zero Drift
±0.005 %
(50 ppm)
±0.1 % ± 10 ppm ± 10 ppm ± 5 ppmC ± 5 ppmC ± 10 ppmC ± 20 ppmC
Response
Time
T90 ≤ 3
seconds
T90 ≤ 3
seconds
T90 ≤ 2
seconds
T90 ≤ 2
seconds
T90 ≤ 2
seconds
T90 ≤ 2
seconds
T90 ≤ 2
seconds
T90 ≤ 2
seconds
Flow Rate 2 lpm 2 lpm 3 lpm 3 lpm 2 lpm 2 lpm 2 lpm 2 lpm
Data Rate 0.833 Hz 0.833 Hz up to 4 Hz up to 4 Hz up to 4 Hz up to 4 Hz up to 4 Hz up to 4 Hz
NOTE: Specifications are subject to change without no-
tice. While due caution has been exercised in the produc-
tion of this document, possible errors and omissions can
occur.
R 05/09
4
SEMTECH-DS
On Board, In-Use Emissions Analyzer
Ambient operating temperature: 0°C to 45°C
Storage temperature: -40°C to 60°C
Sample flow rate: 8 SLPM
Sample rate: 1 Hz
Warm up time: 60 minutes, at 20°C ambient
Power requirements: 12VDC , 70A during warm-up, 30A at steady state
Communications: 802.3 (10BaseT) and 802.3u (100BaseTX) wired,
and 802.11b or 802.11g (DSSS) wireless Ethernet
Chassis dimensions: 36cm x 43cm x 55cm (HxWxD)
Weight: 35.4kg (78 lbs)

More Related Content

PDF
1.semtech ds-gaseous portableemissionsmeasurementsystem–brochure
PDF
Serinus 10-ozone-o3-gas-analyser
PDF
Non-Contact Radar Level Transmitter From Magnetrol
PDF
Top Ten Advances In RTD Signal Conditioning
PDF
SENSIT Portable Methane Detector | Gas Analyzer | PMD
PDF
SENSIT Gas Trac LZ-30 Leak Detector
PDF
VEGA VEGAPULS 61 Radar Level Sensor
PDF
KwikSense Smart Digital Gas Transmitter
1.semtech ds-gaseous portableemissionsmeasurementsystem–brochure
Serinus 10-ozone-o3-gas-analyser
Non-Contact Radar Level Transmitter From Magnetrol
Top Ten Advances In RTD Signal Conditioning
SENSIT Portable Methane Detector | Gas Analyzer | PMD
SENSIT Gas Trac LZ-30 Leak Detector
VEGA VEGAPULS 61 Radar Level Sensor
KwikSense Smart Digital Gas Transmitter

What's hot (18)

PDF
PDS-002-A-1-DSP4000 (2)
PDF
Serinus 50-so2-gas-analyser
PDF
Drager Polytron Pulsar Fixed Gas Detectors - Spec Sheet
PDF
Roxar sand-monitor -pig-detector brochure
PDF
9200+ datasheet
PDF
Dräger X-am 7000 Portable Gas Detector - Spec Sheet
PDF
Aquilar - Leak Detection Brochure
PDF
PDF
Drager Polytron 8310 Fixed Gas Detector - Spec Sheet
PDF
2015_Mead_Patrick_Design_Portfolio_PCB
PDF
SenseTek Stratos HSSD2 datasheet
PDF
Refrigeration Industry Gas Detection Applications
PDF
Sound power | Dewesoft
PDF
Vega Vegapuls wl 61 Radar Level Sensor For Water Management
PDF
ENVI_AMC.PDF
PDF
Drager Polytron Pulsar Duct Mount Fixed Gas Detector - Spec Sheet
PDF
Geophones brochure sercel_en
PDF
Murco MGS-250 Infrared Refrigerant Gas Detector
PDS-002-A-1-DSP4000 (2)
Serinus 50-so2-gas-analyser
Drager Polytron Pulsar Fixed Gas Detectors - Spec Sheet
Roxar sand-monitor -pig-detector brochure
9200+ datasheet
Dräger X-am 7000 Portable Gas Detector - Spec Sheet
Aquilar - Leak Detection Brochure
Drager Polytron 8310 Fixed Gas Detector - Spec Sheet
2015_Mead_Patrick_Design_Portfolio_PCB
SenseTek Stratos HSSD2 datasheet
Refrigeration Industry Gas Detection Applications
Sound power | Dewesoft
Vega Vegapuls wl 61 Radar Level Sensor For Water Management
ENVI_AMC.PDF
Drager Polytron Pulsar Duct Mount Fixed Gas Detector - Spec Sheet
Geophones brochure sercel_en
Murco MGS-250 Infrared Refrigerant Gas Detector
Ad

Viewers also liked (18)

PDF
Correccion perfil
PDF
San Francisco Mobility Access and Pricing Study: Study Findings and Public Fe...
PDF
San Francisco Transportation Plan Overview - Fall 2010
PPTX
Grouping Numbers
PDF
Presstrade Corporate Presentation September 2009
PDF
Mi viaje a Argentina
PDF
ICS Heat Pump Technology Product Guide Feb 2011
PPTX
Public information
PDF
Allelys General Corporate Presentation February 2011
PDF
Semtech Efm Hs High Speed Flow Tube
PDF
Semtech Fs Particulate Measuring System
PDF
Ecostar Brochure
PPT
Sulle note di mariele
PDF
Semtech PPMD Portable Particulate Measuring Device
PPT
Spedicati valentina
PPTX
Odd or Even
PPT
How To Guide for Event Planning
Correccion perfil
San Francisco Mobility Access and Pricing Study: Study Findings and Public Fe...
San Francisco Transportation Plan Overview - Fall 2010
Grouping Numbers
Presstrade Corporate Presentation September 2009
Mi viaje a Argentina
ICS Heat Pump Technology Product Guide Feb 2011
Public information
Allelys General Corporate Presentation February 2011
Semtech Efm Hs High Speed Flow Tube
Semtech Fs Particulate Measuring System
Ecostar Brochure
Sulle note di mariele
Semtech PPMD Portable Particulate Measuring Device
Spedicati valentina
Odd or Even
How To Guide for Event Planning
Ad

Similar to Semtech DS Portable Emissions Measuring System (20)

PDF
DESIGN AND FABRICATION OF EXHAUST GAS ANALYZER
PDF
Semtech AM Activity Monitor
PDF
PPT _ 2022 Norway Customer Event_Introduction to CEMS .pdf
PPTX
Automotive Testing Instruments(Exhaust Eamission) by OEM Technological Instru...
PDF
Materi Pengenalan produk Cemtek untuk cement industry .pdf
PDF
IMR 7500_eng(1)
PDF
IRJET- Design of Eco Friendly System in Automobile for Environmental Safety
PPT
Refinery meet
PPTX
The Technologies Used For Exhaust Emission Monitoring
PDF
ABB CEMS Datasheet ABB cems solution and products information
PDF
Ecotech serinus-56-ts-analyser
PDF
8 Gaseous CEMS fundamentals - reference to thermal power suitability and limi...
PDF
COMETS: compact ambient air monitoring station by ETS
PDF
ATIs-D12-Digital-Gas-Transmitter.pdf
PDF
Ecotech serinus-44-ammonia-analyser
PDF
Dgs co 968-034 digital co sensor module
PDF
Ec91 Intrinsically Safe Oxygen Analyser
PDF
Combustion Analyzer to Add Extra Layer of Safety to Burner Management System
PDF
WDG-V Thermox Combustion Analyzer
PDF
Envea cems emission- monitoring-catalogue-en_s
DESIGN AND FABRICATION OF EXHAUST GAS ANALYZER
Semtech AM Activity Monitor
PPT _ 2022 Norway Customer Event_Introduction to CEMS .pdf
Automotive Testing Instruments(Exhaust Eamission) by OEM Technological Instru...
Materi Pengenalan produk Cemtek untuk cement industry .pdf
IMR 7500_eng(1)
IRJET- Design of Eco Friendly System in Automobile for Environmental Safety
Refinery meet
The Technologies Used For Exhaust Emission Monitoring
ABB CEMS Datasheet ABB cems solution and products information
Ecotech serinus-56-ts-analyser
8 Gaseous CEMS fundamentals - reference to thermal power suitability and limi...
COMETS: compact ambient air monitoring station by ETS
ATIs-D12-Digital-Gas-Transmitter.pdf
Ecotech serinus-44-ammonia-analyser
Dgs co 968-034 digital co sensor module
Ec91 Intrinsically Safe Oxygen Analyser
Combustion Analyzer to Add Extra Layer of Safety to Burner Management System
WDG-V Thermox Combustion Analyzer
Envea cems emission- monitoring-catalogue-en_s

Recently uploaded (20)

PDF
Web App vs Mobile App What Should You Build First.pdf
PPTX
TechTalks-8-2019-Service-Management-ITIL-Refresh-ITIL-4-Framework-Supports-Ou...
PDF
Enhancing emotion recognition model for a student engagement use case through...
PDF
2021 HotChips TSMC Packaging Technologies for Chiplets and 3D_0819 publish_pu...
PPTX
MicrosoftCybserSecurityReferenceArchitecture-April-2025.pptx
PDF
Zenith AI: Advanced Artificial Intelligence
PPTX
Modernising the Digital Integration Hub
PDF
Architecture types and enterprise applications.pdf
PDF
Univ-Connecticut-ChatGPT-Presentaion.pdf
PDF
NewMind AI Weekly Chronicles – August ’25 Week III
PPTX
Chapter 5: Probability Theory and Statistics
PDF
Hybrid model detection and classification of lung cancer
PPTX
Tartificialntelligence_presentation.pptx
PDF
A contest of sentiment analysis: k-nearest neighbor versus neural network
PDF
NewMind AI Weekly Chronicles - August'25-Week II
PPTX
Group 1 Presentation -Planning and Decision Making .pptx
PDF
A novel scalable deep ensemble learning framework for big data classification...
PDF
TrustArc Webinar - Click, Consent, Trust: Winning the Privacy Game
PDF
Hindi spoken digit analysis for native and non-native speakers
PDF
Developing a website for English-speaking practice to English as a foreign la...
Web App vs Mobile App What Should You Build First.pdf
TechTalks-8-2019-Service-Management-ITIL-Refresh-ITIL-4-Framework-Supports-Ou...
Enhancing emotion recognition model for a student engagement use case through...
2021 HotChips TSMC Packaging Technologies for Chiplets and 3D_0819 publish_pu...
MicrosoftCybserSecurityReferenceArchitecture-April-2025.pptx
Zenith AI: Advanced Artificial Intelligence
Modernising the Digital Integration Hub
Architecture types and enterprise applications.pdf
Univ-Connecticut-ChatGPT-Presentaion.pdf
NewMind AI Weekly Chronicles – August ’25 Week III
Chapter 5: Probability Theory and Statistics
Hybrid model detection and classification of lung cancer
Tartificialntelligence_presentation.pptx
A contest of sentiment analysis: k-nearest neighbor versus neural network
NewMind AI Weekly Chronicles - August'25-Week II
Group 1 Presentation -Planning and Decision Making .pptx
A novel scalable deep ensemble learning framework for big data classification...
TrustArc Webinar - Click, Consent, Trust: Winning the Privacy Game
Hindi spoken digit analysis for native and non-native speakers
Developing a website for English-speaking practice to English as a foreign la...

Semtech DS Portable Emissions Measuring System

  • 1. SEMTECH® -DSOn Board, In-Use Emissions Analyzer Sinceit’sintroductionin2002,Sensors’SEMTECH-DShassetthestandardfor Portable Emissions Measurement Systems (PEMS). Capable of monitoring the raw exhaust from both spark ignition and compression ignition engines, the DS measures CO, CO2, O2, NO, NO2 and THC, ensuring compliance with EPA’s CFR 1065. Sensors works closely with environmental regulatory agencies and engine manufacturers throughout the world, ensuring that the DS continues to define and raise the global standards for in-use vehicle emissions measurement solutions. The DS comes complete with SENSOR Tech-PC, a powerful emissions software package, primarily intended for controlling the SEMTECH-DS and performing emissions calculations. Built-in flexibility with both digital and analog I/Os enables the user to interface with a number of auxiliary devices, and to set up the system in accordance with specific application needs. A wireless Ethernet connection can be used for communications between SENSOR Tech-PC and the SEMTECH-DS. Emissions Measurement Solutions
  • 2. 2 SEMTECH-DS On Board, In-Use Emissions Analyzer System Features and Benefits Heated FID Sampling: The exhaust sample is maintained at 191°C, using a heated sample line, filter and pump, so as to minimize the loss of hydrocarbons prior to entering the FID chamber for analysis. Sample Conditioning: A compact sample conditioning system is completely contained within the unit, minimizing contamination of the analyzers. NO and NO2 measurement: Proprietary NDUV measures NO and NO2 separately and simultaneously. Pressure Compensation: Sample pumps operate at constant volume, regardless of ambient pressure, ensuring that transport times are independent of altitude. Calibration Utilities: Easy setup and interface to zero calibrate, span and audit all gases, perform leak tests and purge the system. Test Setup Utility: Offers the user maximum control over test parameters, detection levels and calculation limits. PostProcessor:Timealignsdataandcalculatesrealtimemassemissions, raw emission concentrations and fuel economy. Weather Probe: Actual weather information is required for precise humidity compensation. Shock Resistant Design: Meets MIL-STD 810F for shock and vibration. Sample Installations Span Screen of SENSOR Tech-PC Heavy Duty Truck Excavator Passenger Car Snowmobile
  • 3. 3 SEMTECH-DS On Board, In-Use Emissions Analyzer Optional Accessories Heated Sample Line: Various length lines are available, which maintain the exhaust at 191°C. Global Positioning System: Overlay emissions data with route and elevation information. Vehicle Interface: Heavy duty SAE modules and light duty OBD-II modulesareavailable.VehicleECMparametersarerecordedwith the emissions data, with support for 10 different protocols. Environmental Enclosure: Protects the system in harsh environments. Event Marker: Mark start and end points for events with a digital trigger. Auxiliary Break-Out Box: Connect an external RPM probe or other digital inputs to the DS, with data that is time aligned with the emissions measurements. Analog I/O Break-out Box: Customize DAC data with up to 3 analog inputs, and 8 analog outputs with a 0-10V range. Power Supply: A 12VDC supply with either 120VAC or 220VAC input is available, either as a rack mount or a portable unit. Power Splitter Cable: For Heavy Duty 12VDC, this cable allows the simultaneous connection of DS, PPMD, power supply and battery. SENSOR Tech-CT: Post processing application providing in-use compliance test reports, formatted for EPA submission. SENSOR Tech-PC While collecting emissions test data, the user can monitor the system directly from the application software. System status information includes: System flow diagram, with real time temperatures• and pressures throughout the unit. System flags and warnings, for any parameter that• is out of normal range. Real time emissions data display, in tabular and• graphical formats. In addition to the graphing capabilities within SENSOR Tech-PC’s post processor, data is exported into csv format, for easy graphing and reporting. SENSOR Tech- CT post processing software is also available, providing in-use emissions compliance reports in the proper format to upload to the EPA’s Verify (CDX) web site. User Support As with all SEMTECH products, the DS comes with a wide range of customer support. Sensors’ Remote Support, powered by WebEx, enables our trained technicians to view your SEMTECH unit in real-time, to help answer your questions, diagnose issues, and evaluate data, without requiring any additional software. The SEMTECH Users’ Network, SUN, has a forum for users to share insights on best practices for in-use emissions testing, and to stay up to date with the latest software releases. Graphing Feature within the SENSOR Tech-PC Post Processor System Flow Diagram
  • 4. Sensors, Inc. • 6812 State Rd. • Saline, Michigan 48176 • PH:(734) 429-2100 • FX:(734) 429-4080 • www.sensors-inc.com Sensors Europe GmbH • Feldheider Str. 60 • 40699 Erkrath • Germany • PH: +49 (0) 2104-14188-0 • FX: +49 (0) 2104-14188-14 SEMTECH-DS System Specifications Gas CO CO2 NO NO2 THC Range 0 - 8% 0 - 20% 0 - 2,500 ppm 0 - 500 ppm 0 - 100 ppmC 0 - 1,000 ppmC 0 - 10,000 ppmC 0 - 40,000 ppmC Resolution 10 ppm 0.01% 1 ppm 1 ppm 0.1 ppmC 1 ppmC 1 ppmC 10 ppmC Accuracy ±3% of reading or ± 50 ppm ±3% of reading or ± 0.1% ±3% of reading or ± 15 ppm ±3% of reading or ± 10 ppm ±2.0 % of reading or ±5 ppmC ±2.0 % of reading or ±5 ppmC ±2.0 % of reading or ±25 ppmC ±2.0 % of reading or ±100 ppmC Linearity Intercept ≤0.5 % of range 0.990 ≤Slope ≤1.01 SEE ≤1.0 % of range r2 ≥0.998 Intercept ≤1.0 % of range 0.985≤Slope ≤1.015 SEE ≤1.0 % of range r2 ≥0.998 Intercept ≤0.5 % of range 0.990 ≤Slope ≤1.01 SEE ≤1.0 % of range r2 ≥0.998 Repeatability ±2 % of reading or 20 ppm ±2 % of reading or ±0.05 % ±2 % of reading or 5 ppm ±2 % of reading or 5 ppm ±1.0 % of reading or ±2 ppmC ±1.0 % of reading or ±2 ppmC ±1.0 % of reading or ±10 ppmC ±1.0 % of reading or ±40 ppmC Noise ±20 ppm ±0.02% ± 2 ppm ± 2 ppm ± 2 ppmC ± 2 ppmC ± 10 ppmC ± 40 ppmC Span Drift ±2 % of reading or 20 ppm ±2 % of reading or 0.1 % ±2 % of reading or 20 ppm ± 10 ppm ±1.0 % of reading or 3 ppmC ±1.0 % of reading or 3 ppmC ±1.0 % of reading or 15 ppmC ±1.0 % of reading or 60 ppmC Zero Drift ±0.005 % (50 ppm) ±0.1 % ± 10 ppm ± 10 ppm ± 5 ppmC ± 5 ppmC ± 10 ppmC ± 20 ppmC Response Time T90 ≤ 3 seconds T90 ≤ 3 seconds T90 ≤ 2 seconds T90 ≤ 2 seconds T90 ≤ 2 seconds T90 ≤ 2 seconds T90 ≤ 2 seconds T90 ≤ 2 seconds Flow Rate 2 lpm 2 lpm 3 lpm 3 lpm 2 lpm 2 lpm 2 lpm 2 lpm Data Rate 0.833 Hz 0.833 Hz up to 4 Hz up to 4 Hz up to 4 Hz up to 4 Hz up to 4 Hz up to 4 Hz NOTE: Specifications are subject to change without no- tice. While due caution has been exercised in the produc- tion of this document, possible errors and omissions can occur. R 05/09 4 SEMTECH-DS On Board, In-Use Emissions Analyzer Ambient operating temperature: 0°C to 45°C Storage temperature: -40°C to 60°C Sample flow rate: 8 SLPM Sample rate: 1 Hz Warm up time: 60 minutes, at 20°C ambient Power requirements: 12VDC , 70A during warm-up, 30A at steady state Communications: 802.3 (10BaseT) and 802.3u (100BaseTX) wired, and 802.11b or 802.11g (DSSS) wireless Ethernet Chassis dimensions: 36cm x 43cm x 55cm (HxWxD) Weight: 35.4kg (78 lbs)