SlideShare a Scribd company logo
Continuous Ambient Air Quality
Micro-Monitoring Station
(caaqMMS)
Low-cost sensor-based air monitoring systems are ready to
meet the ambient air quality monitoring needs of today
AirSENCE is an Advanced, Accurate & Affordable continuous ambient air quality Micro-Monitoring
Station- caaqMMS which provides continuous, real-time, accurate and reliable measurements of air
pollution and local weather data.
AirSENCE provides concentrations for gaseous pollutants
including NO, NO2, CO, O3, SO2, VOC, H2S, and CO2 in addition
to all particulate matter fractions such as PM10, PM2.5, and PM1.
Local weather and environmental data, such as wind speed
and direction, noise, rainfall, and light, can also be measured.
AirSENCE has been developed in collaboration with the Southern Ontario Centre for Atmospheric
Aerosol Research (SOCAAR) at the University of Toronto, a leading-edge research institute. It
incorporates a fast-response, multi-parameter sensor array and robust machine learning-based signal
processing and data fusion to provide an Industrial Internet of Things (IIoT) network for real-time, 24/7
ambient air monitoring.
AirSENCE is applicable for many kinds of ambient air monitoring applications including:
• Urban pollution monitoring
• Industrial fence-line monitoring
• Ambient air quality research
• Air monitoring linked to quick action
plans
• And many more....
AirSENCE is highly effective for applications that demand a fast response to air pollution events like
school air quality measurements, particulate monitoring on railway stations and/or loading stations, air
monitoring of airports and seaports, etc. It is also an ideal and economical solution for large, critical
projects like urban baseline data collection.
AirSENCE can be a cost-effective partner for your air monitoring needs as it provides accurate
data, simple operation, portability, advanced communication, and secured cloud storage with
minimal maintenance requirements. It is everything that you expect in a low-cost air monitoring
station.
AirSENCE is ideally suited by design to complement and support stationary ambient air quality stations
by enabling efficient and accurate ambient air mapping.
ACCURATE DATA
Data generated by AirSENCE shows high
correlation with reference system data.
HIGH RESOLUTION DATA
AirSENCE provides high temporal resolution by
generating continuous real-time data every
minute. User may opt for data with shorter or
longer intervals, depending on requirements.
LOW POWER CONSUMPTION
AirSENCE has an average power consumption
of only 6 Watts and can be operated using solar
power or external battery.
MODLAR DESIGN
AirSENCE has a plug-and-play sensor design
and sensors can be replaced in the field in
minutes.
TINY FOOTPRINT
AirSENCE is small and lightweight, making it
portable and easy to install.
ANYWHERE INSTALLATION
AirSENCE can be installed on a pole or on any
vertical surface.
WEATHERPROOF ENCLOSURE
AirSENCE has an IP55 rated weatherproof
polycarbonate enclosure that allows installation
in virtually any climate.
MULTIPLE COMMUNICATION MODES
AirSENCE offers 3 different communication
modes including Wi-Fi, local area network (LAN)
and 4G-LTE GSM.
DATA STORAGE & ACCESS
Every AirSENCE device stores data on a cloud
server with web-browser based secure access
having individual user-ID and password. Users
can access data anytime from anywhere using a
computer or any mobile device.
AirSENCE – SALIENT FEATRES
Dimensions 322mm × 239mm × 177 mm (12.7" × 9.4" × 7.0")
Weight 2.2 kg (4.8 lbs]
Operating Temperature Range -35–+55°C
Operating Pressure Range 30–110 kPa (4.35–15.95 psi)
Humidity Range 0–95% RH
Communication Ethernet, Wi-Fi, 4G LTE Cellular with fallback to 3G
Enclosure Details
Material Polycarbonate
Rating NEMA 4 / NEMA 4 x IP55 sealing
Mounting Options Pole mount or wall mount (kits available)
Power Supply 9–36 VDC at 5 A or Power over Ethernet (PoE)
Power Consumption Typical 6 W, Max 10 W; w/Cellular: Max 15 W
Certification
AirSENCE has an on-board micro-computer with the following specifications:
Computer Type Micro-computer for IoT applications
Brand Onion Omega
Mounting Surface Mount
Computing Drop-in Wi-Fi-enabled Linux computing
Dimensions 34 x 20 x 2.8 mm
Components Built-in CPU, memory and flash storage
Processor 580 MHz MIPS MT7688AN CPU
Other feathers USB, Ethernet, 2xUART’s, 12C, GPIOs interfaces
Storage 35 GB (stores data for >5 years)
• Data is recorded at 1-minute intervals and is user-configurable for longer intervals.
• Finalized data is transferred from AirSENCE to AUG’s cloud server or user’s private server.
• Data is never handled by external software during transfer from AirSENCE to cloud server.
• Data can be viewed on AUG dashboard using individual secure login credentials.
• Users can view and compare data of multiple AirSENCE devices on a single dashboard.
• Downloading data can be averaged over configurable intervals such as 1-minute, 2-minute,
15-minute, 30-minute, or 1-hour.
GENERAL SYSTEM SPECIFICATIONS
Physical
Electrical
DATA MANAGEMENT
Data Computing and Storage
Data Accessibility
Particulate Matter <10 µm (PM10) 0–1,000 µg/m3
Wind Speed & Direction
Particulate Matter <2.5 µm (PM2.5) 0–1,000 µg/m3
Rain Gauge
Particulate Matter <10 µm (PM1) 0–1,000 µg/m3
Noise
Nitric Oxide (NO) 0–6,000 ppb Solar & UV Radiation
Nitrogen Dioxide (NO2) 0–10,000 ppb
Carbon Monoxide (CO) 0–8,000 ppb
Ozone (O3) 0–10,000 ppb
Sulfur Dioxide (SO2) 0–10,000 ppb
Carbon Dioxide (CO2) 0–10,000 ppm
Hydrogen sulfide (H2S) 0–2,000 ppb
VOC 0–40 ppm
AirSENCE DUST-WATCH
Configuration:
PM Sensor (PM10, PM2.5, PM1),
Temperature, humidity, wind speed and wind direction, ambient noise
AirSENCE STANDARD
Configuration:
NO, NO2, CO, O3, SO2, PM (PM10, PM2.5, PM1),
Temperature, humidity, wind speed and wind direction
AirSENCE PRO
Configuration:
NO, NO2, CO, O3, SO2, PM (PM10, PM2.5, PM1),
Temperature, humidity, wind speed and wind direction, ambient noise
AirSENCE ELITE
Configuration:
NO, NO2, CO, O3, SO2, VOC, CO2, H2S, PM (PM10, PM2.5, PM1),
Temperature, humidity, wind speed and wind direction, ambient noise, rainfall
SENSORS SPECIFICATIONS
Parameter/Pollutant Detection Optional Weather Sensor
RECONFIGURED MODELS
Air monitoring in urban areas has become a necessity due to
the exponential growth of cities. Emissions from
increasingly dense vehicular and infrastructure activities
are the major sources of air pollution in these areas and
have completely changed the air quality characteristics of
major cities around the world. Most of these cities still lack
comprehensive air pollutant baseline data which is a major
hurdle in formulating development strategies and
infrastructure planning.
Conventional air monitoring systems have severe limitations
for creating spatial and temporal pollution maps because of
their size and cost. Cities currently in need of air mapping
require networks of low-cost air monitoring systems rather
than measurements at just a few locations.
The Advanced, Accurate and Affordable features of AirSENCE are the perfect fit for creating urban air
mapping networks. Its small footprint, low initial cost of procurement, accuracy of results, ease of
installation, operation and maintenance, and autonomous operation and data handling make it an ideal
choice for urban air quality monitoring.
Recommended Model: AirSENCE PRO
Coal-based power plants continue to be operated on a
massive scale around the world. They are major
contributors to the world's air pollution because of the
sheer volumes of coal they burn coupled with
insufficient treatment of their emissions.
Major air pollutants emitted to the atmosphere from
coal-based thermal power plants are particulates, NOX
and SOX. Particulate matter generated during coal
combustion includes fly ash as well as fine particles of
sulphate, nitrate, and un-combusted coal. Due to the
great height of power plants stacks, severe effects of
these emissions show up several kilometers downwind
of these plants and can extend for several hundred
kilometers.
As a caaqMMS, AirSENCE provides real-time continuous measurements of all PM fractions and other
gaseous pollutants along with essential weather parameters. Its unique features make it an ideal
solution to monitor ambient air around thermal power stations.
Since most of these plants are situated at remote locations, features like low cost of procurement, ease
of installation, autonomous operation, low maintenance cost, remote data storage, accessibility of data
on smartphone, and networking of devices make AirSENCE the best solution for this highly critical
application.
Recommended Model: AirSENCE STANDARD
URBAN CITY MONITORING
THERMAL POWER PLANT
While cement is an essential raw material for the
development and continued growth of any country, its
production is a major contributor to the world’s total air
pollution load. Every aspect of the cement industry
contributes to the problem, including extraction &
transportation of raw materials, manufacturing, and
transportation of the finished product.
The cement industry heavily emits both gaseous as well as
particulate pollutants. Major gaseous pollutants emitted
during the manufacturing process are CO2, CO, NOX, and
VOCs. Particulate pollutants are produced at every stage
of cement manufacturing from raw material extraction to
finished product transportation, and include all PM fractions:
PM10, PM2.5, and PM1.
As a caaqMMS with sensors for NO, NO2, CO2, VOC and PM, as well as wind speed and direction,
AirSENCE provides a tailor-made solution for real-time continuous monitoring of ambient air in and
around cement industries. Features like cost effectiveness, operational simplicity, lack of routine
maintenance protocols, and ease of data storing and viewing makes it the complete air monitoring
solution for cement manufacturers.
Recommended Model: AirSENCE STANDARD
Chemical industries and refineries are major global sources of
many gaseous pollutants, particularly VOCs. These industries
are critical contributors to the world’s overall air pollution load
as they emit pollutant gases not only during their
manufacturing processes but also during the transportation of
raw materials and finished products.
VOCs emitted from such plants are now a major cause of
concern for authorities and citizens situated around them, as
these compounds are an indirect but major contributor in
smog generation. VOCs and NO2 in ambient air generate
tropospheric O3 in the presence of sunlight. This tropospheric
O3 generates smog when combined with PM2.5 particles and NO2,
and is a major nuisance around the world as it leads to road accidents and respiratory diseases.
AirSENCE is a caaqMMS with a full range of gas sensors making it an ideal solution for continuously
monitoring ambient air in and around such chemical plants and refineries. AirSENCE can be
effectively used by authorities to carry out air pollution monitoring of areas with chemical industries
as well as residential areas in their vicinities. Data provided by AirSENCE can be best utilized by
authorities to understand how and to what magnitude these air pollutants infiltrate into residential
areas and take appropriate remedial measures.
Recommended Model: AirSENCE ELITE
CEMENT PLANTS
CHEMICAL INDUSTRIES, REFINERIES & INDUSTRIAL AREAS
Nowadays it has become essential to monitor air in and
around mass commuting areas like airports, railway
stations, and even seaports.
Ambient air around any airport usually has high
concentrations of particulate matter and gaseous
pollutants like NO, NO2, and VOCs, which are emitted as
a result of aircraft operation as well as transportation and
fueling. These pollutants are able to infiltrate into airport
terminals and severely affect the well-being of travelers
and employees. High commuter turnouts also elevate
CO2 and noise levels inside the terminals.
AirSENCE, with sensors for all gaseous and PM pollutants
combined with ambient noise sensing, provides a tailor-made solution for airport authorities to monitor
external and internal air. The advanced features and accurate data of AirSENCE allow authorities to take
immediate corrective actions.
Railways and seaports also have remarkably high concentrations of particulate & noise pollution.
Continuous movement of trains causes particulate matter to enter inside railway stations, while high
commuter volumes, public address announcements, and train horns increase noise pollution and affect
commuters adversely. Similarly for seaports, the continuous loading and unloading of ships generate
substantial amounts of particulate pollution, as well as very high levels of noise coming from high decibel
ship horns.
Recommended Model: For Airports AirSENCE ELITE
For Railway Stations & Seaports AirSENCE DUST-WATCH
Various studies by well-known universities have explicitly
shown that air pollution in schools is a major cause of poor
performance and attendance of students since they spend
much of their time on school premises.
Due to increased social awareness, parents around the
world are now knowledgeable of the high health hazards
associated with air pollution and they are raising their
concerns with school authorities regarding this issue.
AirSENCE, with its small footprint, ease of operations and
maintenance, and the capability to display air monitoring
results on LCD screens, is a first-rate solution for school
management. Online displays of air quality measurement results impart much-needed confidence to
parents and enhance a school's reputation.
Recommended Model: AirSENCE STANDARD
AIRPORTS / RAILWAY STATIONS / SEAPORTS
SCHOOL PREMISES MONITORING
In recent decades there have been major technological
developments in air monitoring instrumentation and
methods. Air quality research institutes are working on
various applications like determining the sources and
compositions and transportation of air pollution,
conducting exposure assessments, improving
monitoring capabilities, and supporting public health
research.
The extensive research done at these institutes enables
the formulation of more effective and targeted air quality
management solutions. Researchers are developing,
evaluating, and applying measurement and monitoring
capabilities to better characterize source emissions, air
quality, and human and environmental exposures for both individual pollutants and mixtures of air
pollutants.
AirSENCE, a comprehensive caaqMMS with all relevant gas, particulate, and weather sensors, provides
a powerful tool for researchers to carry out short- and long-term studies at various locations. Features
like small footprint, light weight, easy portability, ability to operate in all climates, accurate data, easy
operation, low maintenance, and smartphone accessibility make AirSENCE a premium tool for modern
air quality research.
Recommended Model: AirSENCE ELITE
Megacities produce vast quantities of solid waste,
and landfills create major headaches for
municipalities around the world. In addition to
obnoxious odours, major components of landfill
emissions include CO, NOX, SO2, CO2, particulate
matter, and VOCs.
AirSENCE, a caaqMMS, provides an effective
solution for fence-line monitoring of landfill sites. All
relevant gas and particulate sensors are integrated
in a small and lightweight enclosure, making
AirSENCE the perfect tool for monitoring landfill air
emissions. Easy installation, autonomous operation,
low maintenance, and smartphone accessibility enable
authorities to measure air pollutants of such hazardous sites very effectively from remote locations.
Recommended Model: AirSENCE ELITE
AIR QUALITY RESEARCH
AIR MONITORING AROUND LANDFILL SITES
India (Exclusive)
Eco Ventures Pvt. Ltd.
7/8 Bhaveshwar Bhuvan,
Near Dindayal Upadhyay
Udyan, Portughese Church,
Gokhale Road (North)
Dadar West, Mumbai
India - 400 028
+ 91 22 2437 0520 / 6672
info@eco-ventures.in
UK, Ireland (Exclusive)
Netherlands (non-Exclusive)
Ambisense Ltd.
DCU Alpha,
Glasnevin, Dublin 11,
Ireland
+ 353 1 9072790
info@ambisense.net
China - Provinces - Shanghai,
Shandong, Jiangsu,
Hubei (Exclusive)
TherestofChina—(non-Exclusive)
Shanghai EHSroad
Environmental S&T Co.Ltd.
7/F, Block 2, No.300
Yuankang Road, Baoshan
District, Shanghai, China
+86 13817512016
james.xue@ehsroad.com
Korea (non-Exclusive)
Taesung Global Co., Ltd.
4th Floor, DUBO Bldg., 83-1,
Dasan-Ro, Jung-Ku,
Seoul, Korea (04599)
+82 2 2238 6544
jh.Iee@taesung-global.com
Mexico (non-Exclusive)
Eduardo Arturo Rodriguez
Vite Ricardo Margain 575-420,
Torre C. Santa Engracia. San
Pedro Garza Garcfa, Nuevo
Leén. C.P. 66267, Mexico
+52 55 2299 5000
er.vite@gmaiI.com
+1 416-923-4425
+1 877-756-4628 (fax)
airsence@augsignals.com
www.airsence.com
Corporate Headquarters
A.U.G. Signals Ltd.
73 Richmond Street West, Suite
103, Toronto, Ontario,
Canada MSH 4E8
Manufacturing Facility
A.U.G. Signals Ltd.
60 Clarkson Avenue
York, Ontario, Canada
M6E 2T6
Distributors
Get in touch with us!
Property of A.U.G. Signals Ltd. AUG/AirSENCE/PB/2021/Ver-1/Rev-0421-02

More Related Content

PPT
Air pollution monitoring system using mobile gprs sensors array ppt
PPTX
Fog computing
PDF
FIWARE Tech Summit - Smart Waste Management in India
PDF
fog&Edge computing
PPTX
PDF
IRJET- IOT Based Air and Sound Pollution Monitoring System
PPTX
Fog computing
PPTX
IoT Applications and Networks
Air pollution monitoring system using mobile gprs sensors array ppt
Fog computing
FIWARE Tech Summit - Smart Waste Management in India
fog&Edge computing
IRJET- IOT Based Air and Sound Pollution Monitoring System
Fog computing
IoT Applications and Networks

What's hot (20)

PPTX
Smart Waste Disposal System by Russ Earl Malangen
PPTX
Smart Bins : IOT Based Garbage Monitoring System
PDF
AUTOMATIC IRRIGATION SYSTEM DESIGN AND IMPLEMENTATION BASED ON IOT FOR AGRICU...
PPTX
Human Activity Monitoring System Using Wearable Sensors presentation
PDF
A Literature Survey on Internet of Things (IoT)
PPTX
IoT Based Intelligent Bin For Smart Cities
PPTX
IoT based garbage monitoring system
PPTX
IoT in Agriculture
PPTX
Ambient intelligence
PPTX
Internet of things ppt
PPTX
Garbage monitoring system IOT
PPTX
Home automation
PPTX
Free space optics
PDF
IOT Based Smart Bin
PPTX
Iot based garbage monitoring system
PPTX
Air quality montoring system
PPTX
Free space optical communication (FSO)
PDF
Security in IoT
PPTX
Internet of Things (IoT) and its applications
PPTX
Internet of things(io t) v1 0
Smart Waste Disposal System by Russ Earl Malangen
Smart Bins : IOT Based Garbage Monitoring System
AUTOMATIC IRRIGATION SYSTEM DESIGN AND IMPLEMENTATION BASED ON IOT FOR AGRICU...
Human Activity Monitoring System Using Wearable Sensors presentation
A Literature Survey on Internet of Things (IoT)
IoT Based Intelligent Bin For Smart Cities
IoT based garbage monitoring system
IoT in Agriculture
Ambient intelligence
Internet of things ppt
Garbage monitoring system IOT
Home automation
Free space optics
IOT Based Smart Bin
Iot based garbage monitoring system
Air quality montoring system
Free space optical communication (FSO)
Security in IoT
Internet of Things (IoT) and its applications
Internet of things(io t) v1 0
Ad

Similar to Low-cost sensor-based air monitoring systems (20)

PDF
IRJET - Study on Smart Air Pollution Monitoring System based on IoT
PDF
IRJET - Monitoring Indoor Air Quality in Industries
PDF
IRJET- Pollution Monitoring System using RF Communication
PDF
Design and Implementation of Smart Air Pollution Monitoring System Based on I...
PDF
IRJET- IoT based Air Pollution Monitoring System using Arduino
PDF
DESIGN AND DEVELOPMENT OF SOLAR POWERED AIR POLLUTION AND ENVIRONMENTAL MONIT...
PDF
IRJET- Air Quality and Dust Level Monitoring using IoT
PDF
IRJET- IoT based Air Pollution Monitoring System to Create a Smart Environment
PDF
Air Pollution Monitoring System
PDF
IRJET- An IoT based Low Cost Air Pollution Monitoring System
PDF
Design and Implementation of Smart Environmental Air Pollution Monitoring Sys...
PDF
Presentation.pdfof the searching and design
PDF
[2017/07/11 AI-SOCD] AirBox: a Participatory Ecosystem for PM2.5 Monitoring
PDF
A REVIEW PAPER ON AIR QUALITY METER WITH WARNING SYSTEM
PDF
Air quality monitor as510
PDF
DETECTION OF AIR POLLUTANT USING ZIGBEE
PDF
IRJET - IoT based Smart City and Air Quality Monitor
PDF
40120140505008
PPTX
mSens Presentation
PDF
IRJET- AI to Analyze and Extract Data to Gain Insights About the Spread o...
IRJET - Study on Smart Air Pollution Monitoring System based on IoT
IRJET - Monitoring Indoor Air Quality in Industries
IRJET- Pollution Monitoring System using RF Communication
Design and Implementation of Smart Air Pollution Monitoring System Based on I...
IRJET- IoT based Air Pollution Monitoring System using Arduino
DESIGN AND DEVELOPMENT OF SOLAR POWERED AIR POLLUTION AND ENVIRONMENTAL MONIT...
IRJET- Air Quality and Dust Level Monitoring using IoT
IRJET- IoT based Air Pollution Monitoring System to Create a Smart Environment
Air Pollution Monitoring System
IRJET- An IoT based Low Cost Air Pollution Monitoring System
Design and Implementation of Smart Environmental Air Pollution Monitoring Sys...
Presentation.pdfof the searching and design
[2017/07/11 AI-SOCD] AirBox: a Participatory Ecosystem for PM2.5 Monitoring
A REVIEW PAPER ON AIR QUALITY METER WITH WARNING SYSTEM
Air quality monitor as510
DETECTION OF AIR POLLUTANT USING ZIGBEE
IRJET - IoT based Smart City and Air Quality Monitor
40120140505008
mSens Presentation
IRJET- AI to Analyze and Extract Data to Gain Insights About the Spread o...
Ad

Recently uploaded (20)

DOCX
Business Management - unit 1 and 2
PPTX
Probability Distribution, binomial distribution, poisson distribution
PDF
A Brief Introduction About Julia Allison
PPT
Chapter four Project-Preparation material
PDF
Stem Cell Market Report | Trends, Growth & Forecast 2025-2034
PPT
340036916-American-Literature-Literary-Period-Overview.ppt
PDF
SIMNET Inc – 2023’s Most Trusted IT Services & Solution Provider
PDF
Katrina Stoneking: Shaking Up the Alcohol Beverage Industry
PDF
How to Get Funding for Your Trucking Business
PDF
DOC-20250806-WA0002._20250806_112011_0000.pdf
PPTX
ICG2025_ICG 6th steering committee 30-8-24.pptx
PDF
Ôn tập tiếng anh trong kinh doanh nâng cao
PPTX
Principles of Marketing, Industrial, Consumers,
PDF
How to Get Business Funding for Small Business Fast
PDF
Reconciliation AND MEMORANDUM RECONCILATION
PDF
WRN_Investor_Presentation_August 2025.pdf
PDF
Training And Development of Employee .pdf
PPTX
Lecture (1)-Introduction.pptx business communication
PPT
Data mining for business intelligence ch04 sharda
PPTX
CkgxkgxydkydyldylydlydyldlyddolydyoyyU2.pptx
Business Management - unit 1 and 2
Probability Distribution, binomial distribution, poisson distribution
A Brief Introduction About Julia Allison
Chapter four Project-Preparation material
Stem Cell Market Report | Trends, Growth & Forecast 2025-2034
340036916-American-Literature-Literary-Period-Overview.ppt
SIMNET Inc – 2023’s Most Trusted IT Services & Solution Provider
Katrina Stoneking: Shaking Up the Alcohol Beverage Industry
How to Get Funding for Your Trucking Business
DOC-20250806-WA0002._20250806_112011_0000.pdf
ICG2025_ICG 6th steering committee 30-8-24.pptx
Ôn tập tiếng anh trong kinh doanh nâng cao
Principles of Marketing, Industrial, Consumers,
How to Get Business Funding for Small Business Fast
Reconciliation AND MEMORANDUM RECONCILATION
WRN_Investor_Presentation_August 2025.pdf
Training And Development of Employee .pdf
Lecture (1)-Introduction.pptx business communication
Data mining for business intelligence ch04 sharda
CkgxkgxydkydyldylydlydyldlyddolydyoyyU2.pptx

Low-cost sensor-based air monitoring systems

  • 1. Continuous Ambient Air Quality Micro-Monitoring Station (caaqMMS)
  • 2. Low-cost sensor-based air monitoring systems are ready to meet the ambient air quality monitoring needs of today AirSENCE is an Advanced, Accurate & Affordable continuous ambient air quality Micro-Monitoring Station- caaqMMS which provides continuous, real-time, accurate and reliable measurements of air pollution and local weather data. AirSENCE provides concentrations for gaseous pollutants including NO, NO2, CO, O3, SO2, VOC, H2S, and CO2 in addition to all particulate matter fractions such as PM10, PM2.5, and PM1. Local weather and environmental data, such as wind speed and direction, noise, rainfall, and light, can also be measured. AirSENCE has been developed in collaboration with the Southern Ontario Centre for Atmospheric Aerosol Research (SOCAAR) at the University of Toronto, a leading-edge research institute. It incorporates a fast-response, multi-parameter sensor array and robust machine learning-based signal processing and data fusion to provide an Industrial Internet of Things (IIoT) network for real-time, 24/7 ambient air monitoring. AirSENCE is applicable for many kinds of ambient air monitoring applications including: • Urban pollution monitoring • Industrial fence-line monitoring • Ambient air quality research • Air monitoring linked to quick action plans • And many more.... AirSENCE is highly effective for applications that demand a fast response to air pollution events like school air quality measurements, particulate monitoring on railway stations and/or loading stations, air monitoring of airports and seaports, etc. It is also an ideal and economical solution for large, critical projects like urban baseline data collection. AirSENCE can be a cost-effective partner for your air monitoring needs as it provides accurate data, simple operation, portability, advanced communication, and secured cloud storage with minimal maintenance requirements. It is everything that you expect in a low-cost air monitoring station. AirSENCE is ideally suited by design to complement and support stationary ambient air quality stations by enabling efficient and accurate ambient air mapping.
  • 3. ACCURATE DATA Data generated by AirSENCE shows high correlation with reference system data. HIGH RESOLUTION DATA AirSENCE provides high temporal resolution by generating continuous real-time data every minute. User may opt for data with shorter or longer intervals, depending on requirements. LOW POWER CONSUMPTION AirSENCE has an average power consumption of only 6 Watts and can be operated using solar power or external battery. MODLAR DESIGN AirSENCE has a plug-and-play sensor design and sensors can be replaced in the field in minutes. TINY FOOTPRINT AirSENCE is small and lightweight, making it portable and easy to install. ANYWHERE INSTALLATION AirSENCE can be installed on a pole or on any vertical surface. WEATHERPROOF ENCLOSURE AirSENCE has an IP55 rated weatherproof polycarbonate enclosure that allows installation in virtually any climate. MULTIPLE COMMUNICATION MODES AirSENCE offers 3 different communication modes including Wi-Fi, local area network (LAN) and 4G-LTE GSM. DATA STORAGE & ACCESS Every AirSENCE device stores data on a cloud server with web-browser based secure access having individual user-ID and password. Users can access data anytime from anywhere using a computer or any mobile device. AirSENCE – SALIENT FEATRES
  • 4. Dimensions 322mm × 239mm × 177 mm (12.7" × 9.4" × 7.0") Weight 2.2 kg (4.8 lbs] Operating Temperature Range -35–+55°C Operating Pressure Range 30–110 kPa (4.35–15.95 psi) Humidity Range 0–95% RH Communication Ethernet, Wi-Fi, 4G LTE Cellular with fallback to 3G Enclosure Details Material Polycarbonate Rating NEMA 4 / NEMA 4 x IP55 sealing Mounting Options Pole mount or wall mount (kits available) Power Supply 9–36 VDC at 5 A or Power over Ethernet (PoE) Power Consumption Typical 6 W, Max 10 W; w/Cellular: Max 15 W Certification AirSENCE has an on-board micro-computer with the following specifications: Computer Type Micro-computer for IoT applications Brand Onion Omega Mounting Surface Mount Computing Drop-in Wi-Fi-enabled Linux computing Dimensions 34 x 20 x 2.8 mm Components Built-in CPU, memory and flash storage Processor 580 MHz MIPS MT7688AN CPU Other feathers USB, Ethernet, 2xUART’s, 12C, GPIOs interfaces Storage 35 GB (stores data for >5 years) • Data is recorded at 1-minute intervals and is user-configurable for longer intervals. • Finalized data is transferred from AirSENCE to AUG’s cloud server or user’s private server. • Data is never handled by external software during transfer from AirSENCE to cloud server. • Data can be viewed on AUG dashboard using individual secure login credentials. • Users can view and compare data of multiple AirSENCE devices on a single dashboard. • Downloading data can be averaged over configurable intervals such as 1-minute, 2-minute, 15-minute, 30-minute, or 1-hour. GENERAL SYSTEM SPECIFICATIONS Physical Electrical DATA MANAGEMENT Data Computing and Storage Data Accessibility
  • 5. Particulate Matter <10 µm (PM10) 0–1,000 µg/m3 Wind Speed & Direction Particulate Matter <2.5 µm (PM2.5) 0–1,000 µg/m3 Rain Gauge Particulate Matter <10 µm (PM1) 0–1,000 µg/m3 Noise Nitric Oxide (NO) 0–6,000 ppb Solar & UV Radiation Nitrogen Dioxide (NO2) 0–10,000 ppb Carbon Monoxide (CO) 0–8,000 ppb Ozone (O3) 0–10,000 ppb Sulfur Dioxide (SO2) 0–10,000 ppb Carbon Dioxide (CO2) 0–10,000 ppm Hydrogen sulfide (H2S) 0–2,000 ppb VOC 0–40 ppm AirSENCE DUST-WATCH Configuration: PM Sensor (PM10, PM2.5, PM1), Temperature, humidity, wind speed and wind direction, ambient noise AirSENCE STANDARD Configuration: NO, NO2, CO, O3, SO2, PM (PM10, PM2.5, PM1), Temperature, humidity, wind speed and wind direction AirSENCE PRO Configuration: NO, NO2, CO, O3, SO2, PM (PM10, PM2.5, PM1), Temperature, humidity, wind speed and wind direction, ambient noise AirSENCE ELITE Configuration: NO, NO2, CO, O3, SO2, VOC, CO2, H2S, PM (PM10, PM2.5, PM1), Temperature, humidity, wind speed and wind direction, ambient noise, rainfall SENSORS SPECIFICATIONS Parameter/Pollutant Detection Optional Weather Sensor RECONFIGURED MODELS
  • 6. Air monitoring in urban areas has become a necessity due to the exponential growth of cities. Emissions from increasingly dense vehicular and infrastructure activities are the major sources of air pollution in these areas and have completely changed the air quality characteristics of major cities around the world. Most of these cities still lack comprehensive air pollutant baseline data which is a major hurdle in formulating development strategies and infrastructure planning. Conventional air monitoring systems have severe limitations for creating spatial and temporal pollution maps because of their size and cost. Cities currently in need of air mapping require networks of low-cost air monitoring systems rather than measurements at just a few locations. The Advanced, Accurate and Affordable features of AirSENCE are the perfect fit for creating urban air mapping networks. Its small footprint, low initial cost of procurement, accuracy of results, ease of installation, operation and maintenance, and autonomous operation and data handling make it an ideal choice for urban air quality monitoring. Recommended Model: AirSENCE PRO Coal-based power plants continue to be operated on a massive scale around the world. They are major contributors to the world's air pollution because of the sheer volumes of coal they burn coupled with insufficient treatment of their emissions. Major air pollutants emitted to the atmosphere from coal-based thermal power plants are particulates, NOX and SOX. Particulate matter generated during coal combustion includes fly ash as well as fine particles of sulphate, nitrate, and un-combusted coal. Due to the great height of power plants stacks, severe effects of these emissions show up several kilometers downwind of these plants and can extend for several hundred kilometers. As a caaqMMS, AirSENCE provides real-time continuous measurements of all PM fractions and other gaseous pollutants along with essential weather parameters. Its unique features make it an ideal solution to monitor ambient air around thermal power stations. Since most of these plants are situated at remote locations, features like low cost of procurement, ease of installation, autonomous operation, low maintenance cost, remote data storage, accessibility of data on smartphone, and networking of devices make AirSENCE the best solution for this highly critical application. Recommended Model: AirSENCE STANDARD URBAN CITY MONITORING THERMAL POWER PLANT
  • 7. While cement is an essential raw material for the development and continued growth of any country, its production is a major contributor to the world’s total air pollution load. Every aspect of the cement industry contributes to the problem, including extraction & transportation of raw materials, manufacturing, and transportation of the finished product. The cement industry heavily emits both gaseous as well as particulate pollutants. Major gaseous pollutants emitted during the manufacturing process are CO2, CO, NOX, and VOCs. Particulate pollutants are produced at every stage of cement manufacturing from raw material extraction to finished product transportation, and include all PM fractions: PM10, PM2.5, and PM1. As a caaqMMS with sensors for NO, NO2, CO2, VOC and PM, as well as wind speed and direction, AirSENCE provides a tailor-made solution for real-time continuous monitoring of ambient air in and around cement industries. Features like cost effectiveness, operational simplicity, lack of routine maintenance protocols, and ease of data storing and viewing makes it the complete air monitoring solution for cement manufacturers. Recommended Model: AirSENCE STANDARD Chemical industries and refineries are major global sources of many gaseous pollutants, particularly VOCs. These industries are critical contributors to the world’s overall air pollution load as they emit pollutant gases not only during their manufacturing processes but also during the transportation of raw materials and finished products. VOCs emitted from such plants are now a major cause of concern for authorities and citizens situated around them, as these compounds are an indirect but major contributor in smog generation. VOCs and NO2 in ambient air generate tropospheric O3 in the presence of sunlight. This tropospheric O3 generates smog when combined with PM2.5 particles and NO2, and is a major nuisance around the world as it leads to road accidents and respiratory diseases. AirSENCE is a caaqMMS with a full range of gas sensors making it an ideal solution for continuously monitoring ambient air in and around such chemical plants and refineries. AirSENCE can be effectively used by authorities to carry out air pollution monitoring of areas with chemical industries as well as residential areas in their vicinities. Data provided by AirSENCE can be best utilized by authorities to understand how and to what magnitude these air pollutants infiltrate into residential areas and take appropriate remedial measures. Recommended Model: AirSENCE ELITE CEMENT PLANTS CHEMICAL INDUSTRIES, REFINERIES & INDUSTRIAL AREAS
  • 8. Nowadays it has become essential to monitor air in and around mass commuting areas like airports, railway stations, and even seaports. Ambient air around any airport usually has high concentrations of particulate matter and gaseous pollutants like NO, NO2, and VOCs, which are emitted as a result of aircraft operation as well as transportation and fueling. These pollutants are able to infiltrate into airport terminals and severely affect the well-being of travelers and employees. High commuter turnouts also elevate CO2 and noise levels inside the terminals. AirSENCE, with sensors for all gaseous and PM pollutants combined with ambient noise sensing, provides a tailor-made solution for airport authorities to monitor external and internal air. The advanced features and accurate data of AirSENCE allow authorities to take immediate corrective actions. Railways and seaports also have remarkably high concentrations of particulate & noise pollution. Continuous movement of trains causes particulate matter to enter inside railway stations, while high commuter volumes, public address announcements, and train horns increase noise pollution and affect commuters adversely. Similarly for seaports, the continuous loading and unloading of ships generate substantial amounts of particulate pollution, as well as very high levels of noise coming from high decibel ship horns. Recommended Model: For Airports AirSENCE ELITE For Railway Stations & Seaports AirSENCE DUST-WATCH Various studies by well-known universities have explicitly shown that air pollution in schools is a major cause of poor performance and attendance of students since they spend much of their time on school premises. Due to increased social awareness, parents around the world are now knowledgeable of the high health hazards associated with air pollution and they are raising their concerns with school authorities regarding this issue. AirSENCE, with its small footprint, ease of operations and maintenance, and the capability to display air monitoring results on LCD screens, is a first-rate solution for school management. Online displays of air quality measurement results impart much-needed confidence to parents and enhance a school's reputation. Recommended Model: AirSENCE STANDARD AIRPORTS / RAILWAY STATIONS / SEAPORTS SCHOOL PREMISES MONITORING
  • 9. In recent decades there have been major technological developments in air monitoring instrumentation and methods. Air quality research institutes are working on various applications like determining the sources and compositions and transportation of air pollution, conducting exposure assessments, improving monitoring capabilities, and supporting public health research. The extensive research done at these institutes enables the formulation of more effective and targeted air quality management solutions. Researchers are developing, evaluating, and applying measurement and monitoring capabilities to better characterize source emissions, air quality, and human and environmental exposures for both individual pollutants and mixtures of air pollutants. AirSENCE, a comprehensive caaqMMS with all relevant gas, particulate, and weather sensors, provides a powerful tool for researchers to carry out short- and long-term studies at various locations. Features like small footprint, light weight, easy portability, ability to operate in all climates, accurate data, easy operation, low maintenance, and smartphone accessibility make AirSENCE a premium tool for modern air quality research. Recommended Model: AirSENCE ELITE Megacities produce vast quantities of solid waste, and landfills create major headaches for municipalities around the world. In addition to obnoxious odours, major components of landfill emissions include CO, NOX, SO2, CO2, particulate matter, and VOCs. AirSENCE, a caaqMMS, provides an effective solution for fence-line monitoring of landfill sites. All relevant gas and particulate sensors are integrated in a small and lightweight enclosure, making AirSENCE the perfect tool for monitoring landfill air emissions. Easy installation, autonomous operation, low maintenance, and smartphone accessibility enable authorities to measure air pollutants of such hazardous sites very effectively from remote locations. Recommended Model: AirSENCE ELITE AIR QUALITY RESEARCH AIR MONITORING AROUND LANDFILL SITES
  • 10. India (Exclusive) Eco Ventures Pvt. Ltd. 7/8 Bhaveshwar Bhuvan, Near Dindayal Upadhyay Udyan, Portughese Church, Gokhale Road (North) Dadar West, Mumbai India - 400 028 + 91 22 2437 0520 / 6672 info@eco-ventures.in UK, Ireland (Exclusive) Netherlands (non-Exclusive) Ambisense Ltd. DCU Alpha, Glasnevin, Dublin 11, Ireland + 353 1 9072790 info@ambisense.net China - Provinces - Shanghai, Shandong, Jiangsu, Hubei (Exclusive) TherestofChina—(non-Exclusive) Shanghai EHSroad Environmental S&T Co.Ltd. 7/F, Block 2, No.300 Yuankang Road, Baoshan District, Shanghai, China +86 13817512016 james.xue@ehsroad.com Korea (non-Exclusive) Taesung Global Co., Ltd. 4th Floor, DUBO Bldg., 83-1, Dasan-Ro, Jung-Ku, Seoul, Korea (04599) +82 2 2238 6544 jh.Iee@taesung-global.com Mexico (non-Exclusive) Eduardo Arturo Rodriguez Vite Ricardo Margain 575-420, Torre C. Santa Engracia. San Pedro Garza Garcfa, Nuevo Leén. C.P. 66267, Mexico +52 55 2299 5000 er.vite@gmaiI.com +1 416-923-4425 +1 877-756-4628 (fax) airsence@augsignals.com www.airsence.com Corporate Headquarters A.U.G. Signals Ltd. 73 Richmond Street West, Suite 103, Toronto, Ontario, Canada MSH 4E8 Manufacturing Facility A.U.G. Signals Ltd. 60 Clarkson Avenue York, Ontario, Canada M6E 2T6 Distributors Get in touch with us! Property of A.U.G. Signals Ltd. AUG/AirSENCE/PB/2021/Ver-1/Rev-0421-02