Wall Controller WALLC
Quick Start
Please refer to the chapters below for detailed
information about all aspects of the products
usage.
The device operates in normal control mode or
in management mode. Pushing all four
buttons for 5 sec. will turn the device into
management mode (indicated by blinking
green LED). The management mode will time
out after 10 seconds if no further button is
pushed. Button 3 confirms standard
inclusion or exclusion started by a primary
controller, button 2 issues a Node Information
Frame or wakeup notification, button 4 is used
to add devices into association groups and
button 1 confirms inclusion or exclusion in
NWI (network wide inclusion) mode.
What is Z-Wave?
This device is equipped with wireless
communication complying with the Z-Wave
standard. Z-Wave is the international standard
for wireless communication in smart homes and
buildings. It is using the frequency of 868.42 MHz
(EU) or 908 MHz (US) to realize a very stable and
secure communication between devices of different
origin, type and brand. Each message is
reconfirmed (two-way communication) and every
mains powered node can act as a repeater for
other nodes (meshed network) in case the
receiver is not in direct wireless range of the
transmitter.
Z-Wave
differentiates
between
Controllers and
Slaves. Slaves
are either sensors
(S) trans-mitting
metered or measured data or actuators (A) capable
to execute an action. Controllers are either static
mains powered controllers (C) also referred to as
gateways or mobile battery operated remote
controls (R). This results in a number of possible
communication patterns within a Z-Wave network
that are partly or completely supported by a specific
device.
1. Controllers control actuators.
2. Actuators report change of status back to
controller.
3. Sensors report change of status of
measured values to controller.
4. Sensors directly control actuators.
5. Actuators control other actuators.
6. Remote controls send signals to static
controllers to trigger scenes or other
actions.
7. Remote controls control other actuators.
Product description
The Z-Wave.Me Wall Controller is a Z-Wave device
that can both control other Z-Wave devices and
activate predefined scenes in an IP gateway.
Although it is controlling other devices, the Wall
Controller can’t act as Z-Wave network controller
(primary or secondary) and will always need a Z-
Wave network controller to be included into a Z-
Wave network. The device can be used in different
modes that are selected by configuration
parameters:
1. Control of groups of other Z-Wave devices
using ‘ON’, ‘OFF’ and Dim commands.
2. Control of devices in proximity of the Wall
Controller using ‘ALL ON’ or ‘ALL OFF’
commands.
3. Activation of predefined scenes in Gateways or
other Z-Wave devices.
Installation Guidelines
The device comes ready to use with a battery
already installed. On factory default the device is
not included in any network and any button push
will result in a long red blink indicating an error.
This behavior can be used to test the factory
default or exclusion state.
The device can be mounted on every dry and flat
surface using either screws or double side
adhesive. First the mounting base is fixed on the
2
wall. A next step the switch frame is placed on the
frame and the electronic insert is used to fix the
frame to the mounting base as shown on the image
below. Finally the switching paddle(s) are mounted
on the electronic base.
For battery change, the switching paddle(s) need to
be removed. The CR battery can be replaced by
pushing the little nipple above the battery. The old
battery will slide out and the new battery is inserted
until the nipple will hold it again.
The device can be operated in two different modes:
 Operation Mode: This is the mode where the
device is controlling other Z-Wave devices or
is activating scenes.
 Management Mode: The device is turned into
the management mode by pushing all four
buttons for 5 sec. A blinking green LED
indicates the management mode. In the
management mode the buttons of the device
have different functions. If no further action is
performed the device will turn back to the
normal mode after 10 sec. Any management
action terminates the management mode as
well.
In management mode the following actions can be
performed:
 Button 1 - Network Wide Inclusion: The
device can be included into a Z-Wave
Network from any physical location in the
network. This requires a primary controller
supporting Explorer Frames. This mode lasts
for 20 seconds and stops automatically. Any
button press stops the mode as well.
 Button 2 - Send Node Information Frame and
Wake up Notification. (See explanation in the
respective chapters below)
 Button 3 - Standard Inclusion/Exclusion
Mode: The device is included or excluded
from a controller in direct wireless range. Any
button press stops the mode. Performing an
exclusion of the device from a network resets
the device into its factory default.
 Button 4 - Association Set: To assign target
devices to one of the four association groups.
Refer to the manuals section about
association for more information how to set
and unset association groups.
Behavior within the Z-Wave network
On factory default, the device does not belong to
any Z-Wave network. The device needs to join an
existing wireless network to communicate with the
devices of this network. This process is called
Inclusion. Devices can also leave a network. This
process is called Exclusion. The primary controller
of the Z-Wave network initiates both processes.
This controller will be turned into exclusion
respective inclusion mode. Please refer to your
primary controllers manual on how to turn your
controller into inclusion or exclusion mode. Only if
the primary controller is in inclusion or exclusion
mode, this device can join or leave the network.
Leaving the network - i.e. being excluded - sets the
device back to factory default.
Z-Wave knows two types of inclusion processes: The standard
inclusion requires that both controller and the device to be
included are in physical proximity of few meters. The network
wide inclusion allows including a device on every position in
the network as long as there is at least one wireless
connection to a device already included in the network. This
function however requires that both controller and the device to
3
be included support so-called explorer frames. Please refer to
the technical data of the devices for more information about
explorer frame support.
If the device already belongs to a network, follow
the exclusion process before including it in your
network. Otherwise inclusion of this device will fail.
Once the controller is turned into
standard inclusion mode, turn the Wall
Controller into management mode
and hit Button 3. Entering management mode and
hitting button 3 when the controller is in exclusion
mode exclude the device. To include/exclude the
device in the Network Wide Inclusion Mode turn
the Wall Controller into management mode and
hit Button 1.
Operating the device
Depending on the button mode and command set
configured the Wall Controller can be used in
different ways.
Button modes:
Control with two groups of two buttons (This is
the default mode) One group (No. 1) of devices is
controlled by button 1 and 3, the other group (No.
2) is controlled by button 2 and 4. Clicking the
larger button turns the loads ’ON’, clicking the
smaller button turns the loads ‘OFF’. If double
clicks are enabled in configuration parameters #1
or #2, groups No 3 and No 4 are controlled by short
double click of the buttons.
Dimming commands are sent by holding down the
buttons (Dim UP using Buttons 1 and 2, Dim Down
using Buttons 3 and 4) respective Click + Hold in
case the double click option is enabled.
Control with single buttons In this mode a group
of devices is controlled by a single button: single
click turns ‘ON’; double click turns ‘OFF’ devices in
the group. In case dimmers are controlled, holding
down the button will dim up, click and hold down
will dim down the load. The group number
corresponds to the button label.
Control Commands:
The configuration parameter #11…#14 specifies
what commands are sent when the buttons are
operated.
Direct Control of associated devices using ‘ON’,
‘OFF’, ‘DIM UP’ and ‘DIM DOWN’
(This is the default mode No. 1). Devices in
association groups are controlled using Basic ‘ON’
and ‘OFF’ commands and Dim Start/Stop
commands. This mode implements the
communication pattern 7. The parameter value No.
2 disables the use of Dim commands.
Control of neighboring devices using the ‘ALL
ON’ and ‘ALL OFF’ commands.
The special commands ‘ALL ON’ resp. ‘ALL OFF’
are sent as broadcast to all devices in direct
wireless range. The devices act according to their
individual settings for ‘Switch ALL’ commands. This
mode implements the communication pattern 7.
Simple Scene Activation using configurable
scene control commands
Associated devices in an association group are
controlled by individual commands defined by Z-
Wave command class ‘Scene Controller
Configuration’. One scene number can be
configured per association group. On default, the
scene number equals the association group
number as shown in the figure below. This mode
implements communication patterns 6 and 7. This
mode is typically used to activate scenes in IP
gateways but can also be used to activate
predefined scenes in other scene-capable devices.
4
Enhanced Scene Activation
In this mode every button action can issue a scene
activation command with a dedicated number. The
scene number is a combination of the group
number and the action performed on the button and
has always two digits. The group number defines
the upper digit of the scene number, the action the
lower digit. The following actions are possible:
 1 = On
 2 = Off
 3 = Dim Up Start
 4 = Dim Down Start
 5 = Dim Up Stop
 6 = Dim Down Stop
Example: Clicking/double clicking the button 1 will
issue a scene activation command for scene 11
(button 1 click, event on) and scene 12 (button
double click 1, event off, single button control is
used in this example). This mode implements the
communication pattern 6.
Child Protection
The device can be turned into a child protection
mode. In this mode all local operation is disabled.
The child protection mode MUST be turned on
wirelessly. However, in protected by sequence
mode it is possible to unlock the device for local
operation by pressing any button for 5 seconds.
The unlock state will last for 5 seconds.
Wakeup Intervals - how to
communicate with the device?
This device is battery operated and turned into
deep sleep state most of the time to save battery
power. Communication with the device is limited. In
order to communicate with the device, a static
controller C is needed in the network. This
controller will maintain a mailbox for the battery
operated devices and store commands that cannot
be received during deep sleep state. Without such
a controller, communication may become
impossible and/or the battery lifetime is significantly
decreased.
The device will stay awake right after
inclusion for 2.5 seconds allowing the
controller to perform certain
configuration actions. It is possible to manually
wake up the device by pushing button 2 in
management mode.
The minimum allowed wakeup time is 240s but it’s
strongly recommended to define a much longer
interval since the only purpose of a wakeup should
be the reporting of the battery status or an update
of the child protection settings. Defining Node id of
0 as a destination of the Wakeup Notification will
disable the periodical wakeup function entirely.
It is possible to set the node ID to 255 to send wakeup notifications as
broadcast. In this mode device takes more time to go to sleep and drains
battery faster, but can notify all it's direct neighbors about a wakeup.
Node Information Frame
The Node Information Frame is the business card
of a Z-Wave device. It contains information about
the device type and the technical capabilities. The
inclusion and exclusion of the device is confirmed
by sending out a Node Information Frame. Beside
this it may be needed for certain network
operations to send out a Node Information Frame.
Pressing Button 2 in management mode will issue
a Node Information Frame.
LED Control
• Confirmation - green 2 sec
• Failure - red 2 sec
• Button press confirmation - green 1/4 sec
• Waiting for Network Management mode
selection - green blinks
• Waiting for group selection in Association
Set Mode - green fast blink
• Waiting for NIF in Association Set Mode -
green-red-off blink
Associations
Z-Wave devices control other Z-Wave devices. The
relationship between one device controlling another
device is called association. In order to
control a different device, the
controlling device needs to maintain a
list of devices that will receive
controlling commands. These lists are called
5
association groups and they are always related to
certain events (e.g. button pressed, sensor
triggers,...). In case the event happens, all devices
stored in the respective association group will
receive a common wireless command.
Association Groups
1 By button 1 or single clicks of buttons 1 and 2 (max 8 nodes)
2 By button 2 or double clicks of buttons 3 and 4 (max 8 nodes)
3 By button 3 or single clicks of buttons 1 and 2 (max 8 nodes)
4 By button 4 or double clicks of buttons 3 and 4 (max 8 nodes)
The IP gateway that will receive the scene
activation commands must be placed on all
association groups.
Set and unset associations to actuators
Associations can be assigned and removed either via Z-
Wave commands or using the device itself.
To control a Z-Wave device from the Wall Controller, the
Node id of this device needs to be assigned to one of
the four association groups. This is a three-step process:
1. Turn the Wall Controller into management mode and
hit button 4 within 10 sec. (LED is blinking green
when management mode is reached).
2. Within 10 sec. push the button of the Wall Controller
you like the Z-Wave actuator to be controlled with.
After 10 sec. the devices goes back to sleep. Single
click means adding to this association group,
double click means removing the node selected
in step (3) from this association group.
3. Find the Z-Wave actuator you like to control by the
device. Hit the button on the device to issue a Node
Information Frame within 20 sec. A common way is
hitting a control button one or three times. Please
consult the manual of the device to be controlled for
more information how to issue a Node Information
Frame. Any button press on Wall Controller at this
stage will terminate the process.
Configuration Parameters
Z-Wave products are supposed to work out of the
box after inclusion, however certain configuration
can adapt the function better to user needs or
unlock further enhanced features.
Pair Mode for Button 1 and 3
(Parameter Number 1)
Pair Mode for Button 2 and 4
(Parameter Number 2)
Value Description
0 Separately
1 In pair without double clicks (Default)
2 In pair with double clicks
Control Commands on Group 1
(Parameter Number 11)
Control Commands on Group 2
(Parameter Number 12)
Control Commands on Group 3
(Parameter Number 13)
Control Commands on Group 4
(Parameter Number 14)
Value Description
0 Disabled
1
Switch On/Off and Dim (send Basic Set and Multilevel)
(Default)
2 Switch On/Off only (send Basic Set)
3 Switch All
4 Send Scenes
5 Send Preconfigured Scenes
Typical click timeout
(Parameter Number 20)
Typical time used to differentiate click, hold and
double click
Value Description
1 — 100 in 10ms units (Default 50)
Send the following Switch All commands
(Parameter Number 21)
Value Description
1 Switch off only (Default)
2 Switch on only
255 Switch all on and off
Invert buttons
(Parameter Number 22)
Value Description
0 No (Default)
1 Yes
LED confirmation mode
6
(Parameter Number 24)
This allows saving battery power
Value Description
0 No confirmations
1 Confirm button press
2 Confirm button press and delivery (Default)
Send unsolicited Battery Report on Wake Up
(Parameter Number 30)
Value Description
0 No (Default)
1 To same node as wake up notification
2 Broadcast to neighbors
Batteries
The unit is operated by batteries. Use only
batteries of correct type. Never mix old and
new batteries in the same device. Used
batteries contain hazardous substances and
should not be disposed of with household
waste!
Technical Data
IP Rating IP 20
Battery Type 1 * CR2032
Frequency
EU: 868.4 MHz (EN 300 220) or
RU: 869.0 MHz (GKRCh/EN 300 200) or
US: 908.4 MHz (FCC CFR47 P 15.249)
Wireless Range Up to 100 m outside, on average up to 20 m
inside buildings
Explorer Frame
Support
Yes
SDK 4.54 pl1
Device Type Slave with routing capabilities
Specific Device Class Multilevel Remote Switch
Routing No
FLiRS No
Firmware Version 1.3
Dimensions 50 x 30 x 10 mm
Weight 30 gr.
Z-Wave.Me guarantees that every device is free from
physical defects in material and workmanship under
normal use for one year from the date of purchase. If
the product proves defective during this one-year
warranty period, Z-Wave.Me will replace it free of
charge. Z-Wave.Me does not issue any refunds. This
warranty is extended to the original end user
purchase only and is not transferable. This warranty
does not apply to: (1) damage to units caused by
accident, dropping or abuse in handling, or any
negligent use; (2) units which have been subject to
unauthorized repair, taken apart, or otherwise
modified; (3) units not used in accordance with
instruction; (4) damages exceeding the cost of the
product; (5) transit damage, initial installation costs,
removal cost, or reinstallation cost. For information on
additional devices, please visit us online.
This equipment has been tested and found to
comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable
protection against harmful interference in a
residential installation. This equipment
generates, uses and can radiate radio frequency
energy and if not installed and used in
accordance with the instructions, may cause
harmful interference to radio communications.
However, there is no guarantee that interference
will not occur in a particular installation. If this
equipment does cause harmful interference to
radio or television reception, which can be
determined by turning the equipment off and on,
the user is encouraged to try to correct the
interference by one or more of the following
measures:
(1) Reorient or relocate the receiving antenna.
(2) Increase the separation between the
equipment and receiver. (3) Connect the
equipment into an outlet on a circuit different
from that to which the receiver is connected. (4)
Consult the dealer or an experienced radio/TV
technician for help. Any changes or modification
not expressly approved by the party responsible
for compliance could void the user's authority to
operate the device.
Where shielded interface cables have been
provided with the product or specified additional
components or accessories elsewhere defined to
be used with the installation of the product, they
must be used in order to ensure compliance with
FCC regulations.
CE for Class B ITE (Following European standard
EN55022/1998; EN61000- 3-2/1995; EN61000-
3-3/1995, EN55024/1998, EN60950-1/2001)

More Related Content

PDF
Manual AEO_ZW088-ZWEU key fob gen5
PDF
ZME WALLC-S manual
PDF
Wall Controller 4 Buttons rechargeable Remote Z-Wave Plus - Hank manual
PDF
Wall controller 1 Button rechargeable Remote Z-Wave Plus - Hank Manual
PDF
ZME WALLC-S manual
PDF
Qubino flush dimmer 0 10-v plus user manual_v1.0_eng
PDF
POPP. 4-button remote control key Z-WAVE
PDF
Düwi Control Manual
Manual AEO_ZW088-ZWEU key fob gen5
ZME WALLC-S manual
Wall Controller 4 Buttons rechargeable Remote Z-Wave Plus - Hank manual
Wall controller 1 Button rechargeable Remote Z-Wave Plus - Hank Manual
ZME WALLC-S manual
Qubino flush dimmer 0 10-v plus user manual_v1.0_eng
POPP. 4-button remote control key Z-WAVE
Düwi Control Manual

What's hot (20)

PDF
Duw 05443 manual
PDF
Benext BE_SCENECTRL_manual_us
PDF
Manual tkb tz66d
PDF
Wall dimmer with single paddle and frame tkb manual
PDF
Fgkf 601-en-t-v1.0
PDF
Duw 054368
PDF
4 in 1 multi sensor Philio PSM02 (motion, door/window, temperature, lightness)
PDF
ZME KFOB Manual in_en
PDF
Minilux light wired sensor for outdoor mounting 0-10V manual
PDF
Thermostat with binary sensor input start guide
PDF
Wall Plug switch with Metering Z-Wave.me ZME_064374 manual english
PDF
Mini Socket Dimmer Z-Wave Everspring manual
PDF
IOS/Android Touch lcd gsm alarm system LS-GSM-215
PDF
Fgs 212-en-a-v1.01
PDF
Manual eurotronic comet_en
PDF
Ssr 303 user manual
PDF
99 Zones GSM Wireless Home Alarm Security System Installation Guide
PDF
Manual heatit z-din 616_eng
PDF
Complete Alarm Systems | With 5 wireless sensors and siren | 8 wireless, 4 wi...
PDF
Mini jack on off and counter z wave plus everspring
Duw 05443 manual
Benext BE_SCENECTRL_manual_us
Manual tkb tz66d
Wall dimmer with single paddle and frame tkb manual
Fgkf 601-en-t-v1.0
Duw 054368
4 in 1 multi sensor Philio PSM02 (motion, door/window, temperature, lightness)
ZME KFOB Manual in_en
Minilux light wired sensor for outdoor mounting 0-10V manual
Thermostat with binary sensor input start guide
Wall Plug switch with Metering Z-Wave.me ZME_064374 manual english
Mini Socket Dimmer Z-Wave Everspring manual
IOS/Android Touch lcd gsm alarm system LS-GSM-215
Fgs 212-en-a-v1.01
Manual eurotronic comet_en
Ssr 303 user manual
99 Zones GSM Wireless Home Alarm Security System Installation Guide
Manual heatit z-din 616_eng
Complete Alarm Systems | With 5 wireless sensors and siren | 8 wireless, 4 wi...
Mini jack on off and counter z wave plus everspring
Ad

Viewers also liked (20)

PDF
Teoría gestalt
PDF
Secure SRT322_User__Installation_instructions
PDF
7.4 international expansion.pptx
PPTX
Colour themes and fonts
PDF
Alex Primo no Forum de Cultura Digital
PDF
Μινωική & Μυκηναϊκή διατροφή - http://www.projethomere.com
DOCX
Gilgal second tangazo
PDF
Aplicações Tec Tor
DOCX
AIESEC welcome guide 2012-13
PDF
Promoção Fein - Geralfix
PDF
Λεξικόν της Ελληνικής Αρχαιολογίας-Τόμος-Α-http://www.projethomere.com
PPTX
Cfa in india
PPTX
Events by Lasting Impressions
PDF
Rio+20 - Kurzpräsentation
PDF
Npreg lu
PPTX
Iron mary jeopardy 2
PPT
New technologies functions learned
PPTX
What canada-does-for-haiti
PDF
55kg Greco bracket
PPTX
Media 'main task'
Teoría gestalt
Secure SRT322_User__Installation_instructions
7.4 international expansion.pptx
Colour themes and fonts
Alex Primo no Forum de Cultura Digital
Μινωική & Μυκηναϊκή διατροφή - http://www.projethomere.com
Gilgal second tangazo
Aplicações Tec Tor
AIESEC welcome guide 2012-13
Promoção Fein - Geralfix
Λεξικόν της Ελληνικής Αρχαιολογίας-Τόμος-Α-http://www.projethomere.com
Cfa in india
Events by Lasting Impressions
Rio+20 - Kurzpräsentation
Npreg lu
Iron mary jeopardy 2
New technologies functions learned
What canada-does-for-haiti
55kg Greco bracket
Media 'main task'
Ad

Similar to Z wave.me double controller set for duro 200 manual (20)

PDF
Duw 05460 manual
PDF
Dry contact sensor with temperature sensor start guide
PDF
Manual Motion Sensor - Z-Wave Plus - Hank
PDF
Manual widom universal roller shutter en
PDF
Manual neocoolcam door sensor
PDF
Scenes controller z wave plus remotec
PDF
Z-Wave Keypad Manual - PoPP
PDF
MCO-21-TPS-411 Manual
PDF
Qubino luxy smart light - Z-Wave Plus Manual
PDF
Pop 123610 manual
PDF
In-wall dimmer module Z-Wave Plus Smart Home Europe manual english
PDF
Manual_AD147_20140728.pdf
PDF
Manual sensor temperature and humidity z-wave plus - philio
PDF
Mini price on off z wave plus everspring
PDF
Manual HKZW-FLD01
PDF
Temperature sensor with binary sensor input start guide
PDF
Mco_tps314
PDF
Mco_tps312
PDF
Manual 10 year smoke detector Z-Wave Plus-Popp
PDF
Manual Smoke Sensor 10 years autonomy - Popp
Duw 05460 manual
Dry contact sensor with temperature sensor start guide
Manual Motion Sensor - Z-Wave Plus - Hank
Manual widom universal roller shutter en
Manual neocoolcam door sensor
Scenes controller z wave plus remotec
Z-Wave Keypad Manual - PoPP
MCO-21-TPS-411 Manual
Qubino luxy smart light - Z-Wave Plus Manual
Pop 123610 manual
In-wall dimmer module Z-Wave Plus Smart Home Europe manual english
Manual_AD147_20140728.pdf
Manual sensor temperature and humidity z-wave plus - philio
Mini price on off z wave plus everspring
Manual HKZW-FLD01
Temperature sensor with binary sensor input start guide
Mco_tps314
Mco_tps312
Manual 10 year smoke detector Z-Wave Plus-Popp
Manual Smoke Sensor 10 years autonomy - Popp

More from Domotica daVinci (20)

PDF
Manual de usuario Dongle Zigbee 3.0 Sonoff
PDF
2Channel Dimmer Module Zigbee NetPlus Manual
PDF
Shelly Qubini Dry Contact Module Z-Wave Manual
PDF
Zi-Stick UBS Dongle ZIgbee from Aeotec manual
PDF
Manual controlador de pared Zigbee quatro battery.pdf
PDF
MOES-User-Manual AL23-211223-MHUB-MS.pdf
PDF
Tete thermostatique Zigbee MOES BRT-100 V2.pdf
PDF
Cherubini Meta Z-Wave Double Switch A510083-84-90
PDF
Cherubini Meta Z-Wave Smart Plug Manual A510068
PDF
Wave_Shutter_user_guide_multilang_print_V3.pdf
PDF
Quinto Z-Wave Heltun_HE-RS01_User_Manual_B9AH.pdf
PDF
Z-Wave Fan coil Thermostat Heltun_HE-HT01_User_Manual.pdf
PDF
Manual Eurotronic Thermostatic Valve Comry Z-Wave
PDF
Manual sensor Zigbee 3.0 MOES ZSS-X-PIRL-C
PDF
zigbee motion sensor user manual NAS-PD07B2.pdf
PDF
Range extender 7 - Aeotec - Manual
PDF
Aeotec Multisensor 7 Manual
PDF
Z stick 7 user guide
PDF
ESB 200 H-Tronic Manual
PDF
wiDom Smart Roller Shutter Z-Wave Plus Module Manual
Manual de usuario Dongle Zigbee 3.0 Sonoff
2Channel Dimmer Module Zigbee NetPlus Manual
Shelly Qubini Dry Contact Module Z-Wave Manual
Zi-Stick UBS Dongle ZIgbee from Aeotec manual
Manual controlador de pared Zigbee quatro battery.pdf
MOES-User-Manual AL23-211223-MHUB-MS.pdf
Tete thermostatique Zigbee MOES BRT-100 V2.pdf
Cherubini Meta Z-Wave Double Switch A510083-84-90
Cherubini Meta Z-Wave Smart Plug Manual A510068
Wave_Shutter_user_guide_multilang_print_V3.pdf
Quinto Z-Wave Heltun_HE-RS01_User_Manual_B9AH.pdf
Z-Wave Fan coil Thermostat Heltun_HE-HT01_User_Manual.pdf
Manual Eurotronic Thermostatic Valve Comry Z-Wave
Manual sensor Zigbee 3.0 MOES ZSS-X-PIRL-C
zigbee motion sensor user manual NAS-PD07B2.pdf
Range extender 7 - Aeotec - Manual
Aeotec Multisensor 7 Manual
Z stick 7 user guide
ESB 200 H-Tronic Manual
wiDom Smart Roller Shutter Z-Wave Plus Module Manual

Recently uploaded (20)

PPTX
PROGRAMMING-QUARTER-2-PYTHON.pptxnsnsndn
PPTX
1.pptxsadafqefeqfeqfeffeqfqeqfeqefqfeqfqeffqe
PPTX
title _yeOPC_Poisoning_Presentation.pptx
DOCX
A PROPOSAL ON IoT climate sensor 2.docx
PPTX
Embeded System for Artificial intelligence 2.pptx
PPTX
Presentacion compuuuuuuuuuuuuuuuuuuuuuuu
PPTX
Computers and mobile device: Evaluating options for home and work
PPT
FABRICATION OF MOS FET BJT DEVICES IN NANOMETER
PPTX
DEATH AUDIT MAY 2025.pptxurjrjejektjtjyjjy
PPTX
Entre CHtzyshshshshshshshzhhzzhhz 4MSt.pptx
PPTX
Fundamentals of Computer.pptx Computer BSC
PPTX
A Clear View_ Interpreting Scope Numbers and Features
PPTX
02fdgfhfhfhghghhhhhhhhhhhhhhhhhhhhh.pptx
PPTX
Embedded for Artificial Intelligence 1.pptx
PPTX
code of ethics.pptxdvhwbssssSAssscasascc
PPTX
Prograce_Present.....ggation_Simple.pptx
PDF
PPT Determiners.pdf.......................
DOCX
fsdffdghjjgfxfdghjvhjvgfdfcbchghgghgcbjghf
PPTX
Lecture-3-Computer-programming for BS InfoTech
PPT
Hypersensitivity Namisha1111111111-WPS.ppt
PROGRAMMING-QUARTER-2-PYTHON.pptxnsnsndn
1.pptxsadafqefeqfeqfeffeqfqeqfeqefqfeqfqeffqe
title _yeOPC_Poisoning_Presentation.pptx
A PROPOSAL ON IoT climate sensor 2.docx
Embeded System for Artificial intelligence 2.pptx
Presentacion compuuuuuuuuuuuuuuuuuuuuuuu
Computers and mobile device: Evaluating options for home and work
FABRICATION OF MOS FET BJT DEVICES IN NANOMETER
DEATH AUDIT MAY 2025.pptxurjrjejektjtjyjjy
Entre CHtzyshshshshshshshzhhzzhhz 4MSt.pptx
Fundamentals of Computer.pptx Computer BSC
A Clear View_ Interpreting Scope Numbers and Features
02fdgfhfhfhghghhhhhhhhhhhhhhhhhhhhh.pptx
Embedded for Artificial Intelligence 1.pptx
code of ethics.pptxdvhwbssssSAssscasascc
Prograce_Present.....ggation_Simple.pptx
PPT Determiners.pdf.......................
fsdffdghjjgfxfdghjvhjvgfdfcbchghgghgcbjghf
Lecture-3-Computer-programming for BS InfoTech
Hypersensitivity Namisha1111111111-WPS.ppt

Z wave.me double controller set for duro 200 manual

  • 1. 1 Wall Controller WALLC Quick Start Please refer to the chapters below for detailed information about all aspects of the products usage. The device operates in normal control mode or in management mode. Pushing all four buttons for 5 sec. will turn the device into management mode (indicated by blinking green LED). The management mode will time out after 10 seconds if no further button is pushed. Button 3 confirms standard inclusion or exclusion started by a primary controller, button 2 issues a Node Information Frame or wakeup notification, button 4 is used to add devices into association groups and button 1 confirms inclusion or exclusion in NWI (network wide inclusion) mode. What is Z-Wave? This device is equipped with wireless communication complying with the Z-Wave standard. Z-Wave is the international standard for wireless communication in smart homes and buildings. It is using the frequency of 868.42 MHz (EU) or 908 MHz (US) to realize a very stable and secure communication between devices of different origin, type and brand. Each message is reconfirmed (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter. Z-Wave differentiates between Controllers and Slaves. Slaves are either sensors (S) trans-mitting metered or measured data or actuators (A) capable to execute an action. Controllers are either static mains powered controllers (C) also referred to as gateways or mobile battery operated remote controls (R). This results in a number of possible communication patterns within a Z-Wave network that are partly or completely supported by a specific device. 1. Controllers control actuators. 2. Actuators report change of status back to controller. 3. Sensors report change of status of measured values to controller. 4. Sensors directly control actuators. 5. Actuators control other actuators. 6. Remote controls send signals to static controllers to trigger scenes or other actions. 7. Remote controls control other actuators. Product description The Z-Wave.Me Wall Controller is a Z-Wave device that can both control other Z-Wave devices and activate predefined scenes in an IP gateway. Although it is controlling other devices, the Wall Controller can’t act as Z-Wave network controller (primary or secondary) and will always need a Z- Wave network controller to be included into a Z- Wave network. The device can be used in different modes that are selected by configuration parameters: 1. Control of groups of other Z-Wave devices using ‘ON’, ‘OFF’ and Dim commands. 2. Control of devices in proximity of the Wall Controller using ‘ALL ON’ or ‘ALL OFF’ commands. 3. Activation of predefined scenes in Gateways or other Z-Wave devices. Installation Guidelines The device comes ready to use with a battery already installed. On factory default the device is not included in any network and any button push will result in a long red blink indicating an error. This behavior can be used to test the factory default or exclusion state. The device can be mounted on every dry and flat surface using either screws or double side adhesive. First the mounting base is fixed on the
  • 2. 2 wall. A next step the switch frame is placed on the frame and the electronic insert is used to fix the frame to the mounting base as shown on the image below. Finally the switching paddle(s) are mounted on the electronic base. For battery change, the switching paddle(s) need to be removed. The CR battery can be replaced by pushing the little nipple above the battery. The old battery will slide out and the new battery is inserted until the nipple will hold it again. The device can be operated in two different modes:  Operation Mode: This is the mode where the device is controlling other Z-Wave devices or is activating scenes.  Management Mode: The device is turned into the management mode by pushing all four buttons for 5 sec. A blinking green LED indicates the management mode. In the management mode the buttons of the device have different functions. If no further action is performed the device will turn back to the normal mode after 10 sec. Any management action terminates the management mode as well. In management mode the following actions can be performed:  Button 1 - Network Wide Inclusion: The device can be included into a Z-Wave Network from any physical location in the network. This requires a primary controller supporting Explorer Frames. This mode lasts for 20 seconds and stops automatically. Any button press stops the mode as well.  Button 2 - Send Node Information Frame and Wake up Notification. (See explanation in the respective chapters below)  Button 3 - Standard Inclusion/Exclusion Mode: The device is included or excluded from a controller in direct wireless range. Any button press stops the mode. Performing an exclusion of the device from a network resets the device into its factory default.  Button 4 - Association Set: To assign target devices to one of the four association groups. Refer to the manuals section about association for more information how to set and unset association groups. Behavior within the Z-Wave network On factory default, the device does not belong to any Z-Wave network. The device needs to join an existing wireless network to communicate with the devices of this network. This process is called Inclusion. Devices can also leave a network. This process is called Exclusion. The primary controller of the Z-Wave network initiates both processes. This controller will be turned into exclusion respective inclusion mode. Please refer to your primary controllers manual on how to turn your controller into inclusion or exclusion mode. Only if the primary controller is in inclusion or exclusion mode, this device can join or leave the network. Leaving the network - i.e. being excluded - sets the device back to factory default. Z-Wave knows two types of inclusion processes: The standard inclusion requires that both controller and the device to be included are in physical proximity of few meters. The network wide inclusion allows including a device on every position in the network as long as there is at least one wireless connection to a device already included in the network. This function however requires that both controller and the device to
  • 3. 3 be included support so-called explorer frames. Please refer to the technical data of the devices for more information about explorer frame support. If the device already belongs to a network, follow the exclusion process before including it in your network. Otherwise inclusion of this device will fail. Once the controller is turned into standard inclusion mode, turn the Wall Controller into management mode and hit Button 3. Entering management mode and hitting button 3 when the controller is in exclusion mode exclude the device. To include/exclude the device in the Network Wide Inclusion Mode turn the Wall Controller into management mode and hit Button 1. Operating the device Depending on the button mode and command set configured the Wall Controller can be used in different ways. Button modes: Control with two groups of two buttons (This is the default mode) One group (No. 1) of devices is controlled by button 1 and 3, the other group (No. 2) is controlled by button 2 and 4. Clicking the larger button turns the loads ’ON’, clicking the smaller button turns the loads ‘OFF’. If double clicks are enabled in configuration parameters #1 or #2, groups No 3 and No 4 are controlled by short double click of the buttons. Dimming commands are sent by holding down the buttons (Dim UP using Buttons 1 and 2, Dim Down using Buttons 3 and 4) respective Click + Hold in case the double click option is enabled. Control with single buttons In this mode a group of devices is controlled by a single button: single click turns ‘ON’; double click turns ‘OFF’ devices in the group. In case dimmers are controlled, holding down the button will dim up, click and hold down will dim down the load. The group number corresponds to the button label. Control Commands: The configuration parameter #11…#14 specifies what commands are sent when the buttons are operated. Direct Control of associated devices using ‘ON’, ‘OFF’, ‘DIM UP’ and ‘DIM DOWN’ (This is the default mode No. 1). Devices in association groups are controlled using Basic ‘ON’ and ‘OFF’ commands and Dim Start/Stop commands. This mode implements the communication pattern 7. The parameter value No. 2 disables the use of Dim commands. Control of neighboring devices using the ‘ALL ON’ and ‘ALL OFF’ commands. The special commands ‘ALL ON’ resp. ‘ALL OFF’ are sent as broadcast to all devices in direct wireless range. The devices act according to their individual settings for ‘Switch ALL’ commands. This mode implements the communication pattern 7. Simple Scene Activation using configurable scene control commands Associated devices in an association group are controlled by individual commands defined by Z- Wave command class ‘Scene Controller Configuration’. One scene number can be configured per association group. On default, the scene number equals the association group number as shown in the figure below. This mode implements communication patterns 6 and 7. This mode is typically used to activate scenes in IP gateways but can also be used to activate predefined scenes in other scene-capable devices.
  • 4. 4 Enhanced Scene Activation In this mode every button action can issue a scene activation command with a dedicated number. The scene number is a combination of the group number and the action performed on the button and has always two digits. The group number defines the upper digit of the scene number, the action the lower digit. The following actions are possible:  1 = On  2 = Off  3 = Dim Up Start  4 = Dim Down Start  5 = Dim Up Stop  6 = Dim Down Stop Example: Clicking/double clicking the button 1 will issue a scene activation command for scene 11 (button 1 click, event on) and scene 12 (button double click 1, event off, single button control is used in this example). This mode implements the communication pattern 6. Child Protection The device can be turned into a child protection mode. In this mode all local operation is disabled. The child protection mode MUST be turned on wirelessly. However, in protected by sequence mode it is possible to unlock the device for local operation by pressing any button for 5 seconds. The unlock state will last for 5 seconds. Wakeup Intervals - how to communicate with the device? This device is battery operated and turned into deep sleep state most of the time to save battery power. Communication with the device is limited. In order to communicate with the device, a static controller C is needed in the network. This controller will maintain a mailbox for the battery operated devices and store commands that cannot be received during deep sleep state. Without such a controller, communication may become impossible and/or the battery lifetime is significantly decreased. The device will stay awake right after inclusion for 2.5 seconds allowing the controller to perform certain configuration actions. It is possible to manually wake up the device by pushing button 2 in management mode. The minimum allowed wakeup time is 240s but it’s strongly recommended to define a much longer interval since the only purpose of a wakeup should be the reporting of the battery status or an update of the child protection settings. Defining Node id of 0 as a destination of the Wakeup Notification will disable the periodical wakeup function entirely. It is possible to set the node ID to 255 to send wakeup notifications as broadcast. In this mode device takes more time to go to sleep and drains battery faster, but can notify all it's direct neighbors about a wakeup. Node Information Frame The Node Information Frame is the business card of a Z-Wave device. It contains information about the device type and the technical capabilities. The inclusion and exclusion of the device is confirmed by sending out a Node Information Frame. Beside this it may be needed for certain network operations to send out a Node Information Frame. Pressing Button 2 in management mode will issue a Node Information Frame. LED Control • Confirmation - green 2 sec • Failure - red 2 sec • Button press confirmation - green 1/4 sec • Waiting for Network Management mode selection - green blinks • Waiting for group selection in Association Set Mode - green fast blink • Waiting for NIF in Association Set Mode - green-red-off blink Associations Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called
  • 5. 5 association groups and they are always related to certain events (e.g. button pressed, sensor triggers,...). In case the event happens, all devices stored in the respective association group will receive a common wireless command. Association Groups 1 By button 1 or single clicks of buttons 1 and 2 (max 8 nodes) 2 By button 2 or double clicks of buttons 3 and 4 (max 8 nodes) 3 By button 3 or single clicks of buttons 1 and 2 (max 8 nodes) 4 By button 4 or double clicks of buttons 3 and 4 (max 8 nodes) The IP gateway that will receive the scene activation commands must be placed on all association groups. Set and unset associations to actuators Associations can be assigned and removed either via Z- Wave commands or using the device itself. To control a Z-Wave device from the Wall Controller, the Node id of this device needs to be assigned to one of the four association groups. This is a three-step process: 1. Turn the Wall Controller into management mode and hit button 4 within 10 sec. (LED is blinking green when management mode is reached). 2. Within 10 sec. push the button of the Wall Controller you like the Z-Wave actuator to be controlled with. After 10 sec. the devices goes back to sleep. Single click means adding to this association group, double click means removing the node selected in step (3) from this association group. 3. Find the Z-Wave actuator you like to control by the device. Hit the button on the device to issue a Node Information Frame within 20 sec. A common way is hitting a control button one or three times. Please consult the manual of the device to be controlled for more information how to issue a Node Information Frame. Any button press on Wall Controller at this stage will terminate the process. Configuration Parameters Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features. Pair Mode for Button 1 and 3 (Parameter Number 1) Pair Mode for Button 2 and 4 (Parameter Number 2) Value Description 0 Separately 1 In pair without double clicks (Default) 2 In pair with double clicks Control Commands on Group 1 (Parameter Number 11) Control Commands on Group 2 (Parameter Number 12) Control Commands on Group 3 (Parameter Number 13) Control Commands on Group 4 (Parameter Number 14) Value Description 0 Disabled 1 Switch On/Off and Dim (send Basic Set and Multilevel) (Default) 2 Switch On/Off only (send Basic Set) 3 Switch All 4 Send Scenes 5 Send Preconfigured Scenes Typical click timeout (Parameter Number 20) Typical time used to differentiate click, hold and double click Value Description 1 — 100 in 10ms units (Default 50) Send the following Switch All commands (Parameter Number 21) Value Description 1 Switch off only (Default) 2 Switch on only 255 Switch all on and off Invert buttons (Parameter Number 22) Value Description 0 No (Default) 1 Yes LED confirmation mode
  • 6. 6 (Parameter Number 24) This allows saving battery power Value Description 0 No confirmations 1 Confirm button press 2 Confirm button press and delivery (Default) Send unsolicited Battery Report on Wake Up (Parameter Number 30) Value Description 0 No (Default) 1 To same node as wake up notification 2 Broadcast to neighbors Batteries The unit is operated by batteries. Use only batteries of correct type. Never mix old and new batteries in the same device. Used batteries contain hazardous substances and should not be disposed of with household waste! Technical Data IP Rating IP 20 Battery Type 1 * CR2032 Frequency EU: 868.4 MHz (EN 300 220) or RU: 869.0 MHz (GKRCh/EN 300 200) or US: 908.4 MHz (FCC CFR47 P 15.249) Wireless Range Up to 100 m outside, on average up to 20 m inside buildings Explorer Frame Support Yes SDK 4.54 pl1 Device Type Slave with routing capabilities Specific Device Class Multilevel Remote Switch Routing No FLiRS No Firmware Version 1.3 Dimensions 50 x 30 x 10 mm Weight 30 gr. Z-Wave.Me guarantees that every device is free from physical defects in material and workmanship under normal use for one year from the date of purchase. If the product proves defective during this one-year warranty period, Z-Wave.Me will replace it free of charge. Z-Wave.Me does not issue any refunds. This warranty is extended to the original end user purchase only and is not transferable. This warranty does not apply to: (1) damage to units caused by accident, dropping or abuse in handling, or any negligent use; (2) units which have been subject to unauthorized repair, taken apart, or otherwise modified; (3) units not used in accordance with instruction; (4) damages exceeding the cost of the product; (5) transit damage, initial installation costs, removal cost, or reinstallation cost. For information on additional devices, please visit us online. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: (1) Reorient or relocate the receiving antenna. (2) Increase the separation between the equipment and receiver. (3) Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. (4) Consult the dealer or an experienced radio/TV technician for help. Any changes or modification not expressly approved by the party responsible for compliance could void the user's authority to operate the device. Where shielded interface cables have been provided with the product or specified additional components or accessories elsewhere defined to be used with the installation of the product, they must be used in order to ensure compliance with FCC regulations. CE for Class B ITE (Following European standard EN55022/1998; EN61000- 3-2/1995; EN61000- 3-3/1995, EN55024/1998, EN60950-1/2001)