SlideShare a Scribd company logo
CAPM Software
The CAPM Evolution
 First Generation
 CAPM1
 CAPM2
 CAPM3
 Second Generation
 CAPM4
 CAPM5
CAPM2 Software version naming scheme
 Major Version Number
 Minor Version Number
 Protocol Variant
 Functional Variant
V9. 71 zz aa
Software version naming scheme for CAPM4/5
 Version 21
 Version 22
 Version 23
 Version 24
CAPM4
CAPM5
 Version 26
 Version 27
 Version 28
 Version 26
 Version 27
 Version 28
 Version 25
Exclusive CAPM5 Features
 Frequency Measurement
 Under/Over Frequency Protection
 Fast Trip Input Module
 19.2K Baud Rate on RS-232 Port P8
 Auxiliary Panel Support 
CAPM4/5 Software version naming scheme
 The Software Version
XXX-XX.XX
 The Configuration Number
2XXXX
Examples
Software 028-07.00
Configuration 21186
Software 528-07.00
Configuration 21187
CAPM4 CAPM5
Software Version Details on Operator Panel
CAPM Software Version via WSOS On-Line
Compatibility of CAPM and WSOS Software
Each CAPM software version released
is supported by a Windows Switchgear
Operating System (WSOS) update.
 Always ensure that you have the latest
release WSOS and that it is compatible
with the release version of CAPM
software being installed.
http://www.nulec.com.au/
http://www.nulec.com.au/service/
STAR
*****
Searching for Controller Software
Filtering the Search Conditions
Searching for N Series CAPM5 Software
Search Results
Filtering on Search Description
DNP3
CAPM4/5 Software Upgrade
OBJECTIVE:
 To Install the latest revision software
over an existing version of CAPM4/5
software, whilst retaining all previous
control and protection settings.
Equipment Required
 Nu-Lec Industries Serial Cable Part No:
N05-902
 Laptop Personal Computer (32 bit
system) with the latest version of WSOS
installed.
 The replacement software file.
(i.e. 21728528.13a)
 The cap5load.exe file. 
CAPM Software and Executable Files
CAPM4/5 Software Upgrade Procedure
 Save the existing Switchgear
Configuration Settings.
 Download the CAPM software file to the
controller using cap5load.exe.
 Confirm new software is installed.
 Reload Switchgear Configuration
Settings.
 Compare On-Line and Off-Line files.
 Restore the Switchgear to Service. 
Saving the Existing Switchgear Configuration
Using cap5load to load Software
Trip and Close must be isolated
Download Completed OK
Confirm New Software is Installed
Reloading Switchgear Configuration Settings
Compare Switchgear Settings
Restore ACR to Service
 View the Event Log on the Operator
Control Panel to confirm that a Pickup
event has not been generated.
 Enable the Trip and Close solenoids by
returning both switches to the Enable
position.
 Go off-line with WSOS, disconnect and
store the PC and serial cable. 
CAPM Software Summary
 The latest release of CAPM4/5 software is
version 28.
 Under/Over Frequency Protection is
available on CAPM5 but not CAPM4.
 CAPM4 CAPM5
Software 028-07.00 Software 528-07.00
Configuration 21186 Configuration 21187
 Each CAPM4/5 software release is
supported by a release of WSOS Ver 4.
 CAPM4/5 software is loaded using
cap5load.exe from the Command Prompt.
 The WSOS Compare command can be
used to check that the configuration has
been correctly restored following a CAPM
software upgrade. 

More Related Content

PDF
1.2V Analog I/O with full local ESD protection for TSMC 65nm technology
PDF
DesignCon 2019 112-Gbps Electrical Interfaces: An OIF Update on CEI-112G
PPTX
Network Intrusion Prevention by Configuring ACLs on the Routers, based on Sno...
PDF
Dpdk pmd
PDF
Cloud Network Virtualization with Juniper Contrail
PDF
Percepio Tracealyzer for FreeRTOS on MiniZED
PDF
VMware vSphere Networking deep dive
PPTX
Control Kubernetes Ingress and Egress Together with NGINX
1.2V Analog I/O with full local ESD protection for TSMC 65nm technology
DesignCon 2019 112-Gbps Electrical Interfaces: An OIF Update on CEI-112G
Network Intrusion Prevention by Configuring ACLs on the Routers, based on Sno...
Dpdk pmd
Cloud Network Virtualization with Juniper Contrail
Percepio Tracealyzer for FreeRTOS on MiniZED
VMware vSphere Networking deep dive
Control Kubernetes Ingress and Egress Together with NGINX

What's hot (16)

PDF
IIJmio meeting 19 IIJ フルMVNO徹底解説
PDF
PPTX
MOSFET Process Flow
PPTX
Scylla on Kubernetes: Introducing the Scylla Operator
PDF
إصلاح أنظمة التقاعد المدنية
PDF
Virtual Chassis Fabric for Cloud Builder
PPTX
6. Live VM migration
PPTX
Wide bandgap semiconductor
PDF
Setting and Usage of OpenFOAM multiphase solver (S-CLSVOF)
PPTX
Diameter Presentation
PDF
SDN Presentation
PDF
HPC Best Practices: Application Performance Optimization
PPT
WebLogic Scripting Tool Overview
PDF
What's New In Apache CloudStack 4.17
PDF
ストリーミングのTLS(SSL)化
PPTX
IIJmio meeting 19 IIJ フルMVNO徹底解説
MOSFET Process Flow
Scylla on Kubernetes: Introducing the Scylla Operator
إصلاح أنظمة التقاعد المدنية
Virtual Chassis Fabric for Cloud Builder
6. Live VM migration
Wide bandgap semiconductor
Setting and Usage of OpenFOAM multiphase solver (S-CLSVOF)
Diameter Presentation
SDN Presentation
HPC Best Practices: Application Performance Optimization
WebLogic Scripting Tool Overview
What's New In Apache CloudStack 4.17
ストリーミングのTLS(SSL)化
Ad

Viewers also liked (7)

PPTX
PDF
PDF
Capm theory and evidence by fama french
PDF
Slides money banking risk reward capm
PPT
Capm and apt
PPTX
PPTX
The capital asset pricing model (capm)
Capm theory and evidence by fama french
Slides money banking risk reward capm
Capm and apt
The capital asset pricing model (capm)
Ad

Similar to 01 capm software introduction (20)

PDF
Um basic config_l2p_rel71_en
PDF
ClearPass 6.3.6 Release Notes
PDF
ClearPass 6.3.6 Release Notes
PDF
ArcMC 2.5.1 Release Notes
PDF
PPTX
Vsc 71-se-presentation-training
PDF
Aruba OS 6.4 Command Line Interface Reference Guide
PDF
brochure-deltav-version-15-interactive-flyer-deltav-en-8618114.pdf
PDF
Important cisco-chow-commands
DOCX
Network performance test plan_v0.3
PDF
VMworld 2013: How to Exchange Status Message Between Guest and Host Using RPC
PPTX
Sneak Peek into the New ChangeMan ZMF Release
PPTX
Sneak Peek into the New ChangeMan ZMF Release
PPT
Getting Started With Pb T4 Comment Lan
PDF
PV Elite 2019 Service Pack 2 (Version 21.00.02.0000).
PDF
Kubernetes and the 12 factor cloud apps
PDF
Pandora FMS: Hyper V Plugin
PDF
Kubernetes and the 12 factor cloud apps
PPT
Smart Printing Technical Presentation
PDF
inteligen-500-1-6-0-global-guide.pdfbgfgjjhgggfffgggg
Um basic config_l2p_rel71_en
ClearPass 6.3.6 Release Notes
ClearPass 6.3.6 Release Notes
ArcMC 2.5.1 Release Notes
Vsc 71-se-presentation-training
Aruba OS 6.4 Command Line Interface Reference Guide
brochure-deltav-version-15-interactive-flyer-deltav-en-8618114.pdf
Important cisco-chow-commands
Network performance test plan_v0.3
VMworld 2013: How to Exchange Status Message Between Guest and Host Using RPC
Sneak Peek into the New ChangeMan ZMF Release
Sneak Peek into the New ChangeMan ZMF Release
Getting Started With Pb T4 Comment Lan
PV Elite 2019 Service Pack 2 (Version 21.00.02.0000).
Kubernetes and the 12 factor cloud apps
Pandora FMS: Hyper V Plugin
Kubernetes and the 12 factor cloud apps
Smart Printing Technical Presentation
inteligen-500-1-6-0-global-guide.pdfbgfgjjhgggfffgggg

More from duytn1 (7)

PPT
04 ptcc protection feautres
PPT
05 ptcc automation overview
PPT
06 wsos – an overview
PPT
07 wsos – user guide
PPT
08 wsos features
PPT
09 passwords
PPT
03 ptcc under over voltage protection
04 ptcc protection feautres
05 ptcc automation overview
06 wsos – an overview
07 wsos – user guide
08 wsos features
09 passwords
03 ptcc under over voltage protection

Recently uploaded (20)

PDF
Empathic Computing: Creating Shared Understanding
PDF
Machine learning based COVID-19 study performance prediction
PDF
Optimiser vos workloads AI/ML sur Amazon EC2 et AWS Graviton
PDF
Per capita expenditure prediction using model stacking based on satellite ima...
PPT
“AI and Expert System Decision Support & Business Intelligence Systems”
PPTX
VMware vSphere Foundation How to Sell Presentation-Ver1.4-2-14-2024.pptx
PDF
Review of recent advances in non-invasive hemoglobin estimation
PDF
Network Security Unit 5.pdf for BCA BBA.
PDF
Agricultural_Statistics_at_a_Glance_2022_0.pdf
PDF
7 ChatGPT Prompts to Help You Define Your Ideal Customer Profile.pdf
PDF
Advanced methodologies resolving dimensionality complications for autism neur...
PDF
The Rise and Fall of 3GPP – Time for a Sabbatical?
PPTX
A Presentation on Artificial Intelligence
PDF
Encapsulation_ Review paper, used for researhc scholars
PPTX
20250228 LYD VKU AI Blended-Learning.pptx
PDF
A comparative analysis of optical character recognition models for extracting...
PDF
Profit Center Accounting in SAP S/4HANA, S4F28 Col11
PPTX
MYSQL Presentation for SQL database connectivity
PDF
Chapter 3 Spatial Domain Image Processing.pdf
PDF
Diabetes mellitus diagnosis method based random forest with bat algorithm
Empathic Computing: Creating Shared Understanding
Machine learning based COVID-19 study performance prediction
Optimiser vos workloads AI/ML sur Amazon EC2 et AWS Graviton
Per capita expenditure prediction using model stacking based on satellite ima...
“AI and Expert System Decision Support & Business Intelligence Systems”
VMware vSphere Foundation How to Sell Presentation-Ver1.4-2-14-2024.pptx
Review of recent advances in non-invasive hemoglobin estimation
Network Security Unit 5.pdf for BCA BBA.
Agricultural_Statistics_at_a_Glance_2022_0.pdf
7 ChatGPT Prompts to Help You Define Your Ideal Customer Profile.pdf
Advanced methodologies resolving dimensionality complications for autism neur...
The Rise and Fall of 3GPP – Time for a Sabbatical?
A Presentation on Artificial Intelligence
Encapsulation_ Review paper, used for researhc scholars
20250228 LYD VKU AI Blended-Learning.pptx
A comparative analysis of optical character recognition models for extracting...
Profit Center Accounting in SAP S/4HANA, S4F28 Col11
MYSQL Presentation for SQL database connectivity
Chapter 3 Spatial Domain Image Processing.pdf
Diabetes mellitus diagnosis method based random forest with bat algorithm

01 capm software introduction

Editor's Notes

  • #5: <number> CAPM4 began shipping in 1998. The CAPM5 has been shipped from early 2001. The main reason for the change between CAPM 4 and 5 was the obsolescence of certain components (such as the A/D converters) used on CAPM2 and CAPM4. As a new design was required, it was decided to include functional enhancements requested by customers. These enhancements include: More flash memory to enable larger history and event storage. Additional serial port. Zero crossing detector on 1 phase to support under/over frequency protection. Support for Fast Trip Input Module. Software versions since V25 have supported CAPM4 and CAPM5. Each new software release has been produced in CAPM4 and CAPM5 versions (versions must be different because of the low-level changes and because of the additional memory in the CAPM5).
  • #7: <number> The Software Version identifies the exact software loaded into the program memory on the Controller The Configuration Number identifies the configuration loaded into the database which then controls what the software will do. For example, whether the operater text displays are to be in English or another language.
  • #8: The CAPM software version and configuration numbers can be read from the ‘Switchgear Wear/General Details’ screen in the SystemStatus menu.
  • #9: When WSOS is on-line to the switchgear, the CAPM software version and configuration numbers can be read on the Configuration window.
  • #10: As new features are added to the CAPM software, changes must be made to WSOS in order to support these features. It is important therefore that if you are using the latest CAPM software, you also have a WSOS software release which is compatible.
  • #11: Anyone can download the latest WSOS software from the Nu-Lec web site although it will only run in demonstration mode unless they have a valid WSOS licence. In order to download CAPM software, a Service Login is required.
  • #12: When users enter the Nu-Lec Service web site, they are prompted to enter a Username and Password. Users who have a need to access this site must have their details entered by Nu-Lec who will then issue a Username and Password.
  • #13: Once the Service web site has been accessed, a variety of information can be downloaded. To download CAPM software, click on the Controler Software option in the list on the left hand side of the screen.
  • #14: From the Controller Software Search screen, users can filter their search by selecting on of the options in the drop down lists for Controller/CAPM and Product. The search may be further refined by entering text in the Description field.
  • #15: Select one of the options from the Controller/CAPM and Product drop down lists and click on search to find details of software meeting the search criteria.
  • #16: When the search has finished, a list of software that meets the search criteria will be displayed. Each record contains information such as: CAPM4 or 5 Software version Supported switchgear type Language text Communications protocol supported. Compatible WSOS software version
  • #17: The information entered in the Description field for the search must match the text or a part of the text in the title of the software being sought.
  • #19: The cable used for software loading is the same cable used for WSOS. When the CAPM software is downloaded from the Nu-Lec web site it is in a zip file which also contains: cap5load.exe CAPM4/5 Software Installation Service Procedure document Documentation on the communication protocol supported
  • #20: The cap5load.exe and software files must be loaded into the same folder on the PC to be used for software loading.
  • #22: The first step in the software loading procedure is to save the existing switchgear configuration from the controller that is about to have its CAPM software upgraded. The switchgear configuration is then safely stored on the users PC and cannot be effected by any abnormalities that might occur during the CAPM software upload.
  • #23: cap5load.exe cannot be launched from Explorer. You must firstly launch the Command Prompt and then point the cursor to the folder containing cap5load.exe and the CAPM software file to be loaded. When the correct folder has been selected (nulec sw in the above example) the command ‘cap5load’ can be entered. This will display the correct usage for this command: cap5load [- serial port] [-high:-low] [-force] [issue filename] Where: [- Serial port] is the number of the comms port on your PC being used to connect to the controller. [-high:-low] is the baud rate for the data transfer. This is best left out as it will default to high. [-force] This is also optional but is recommended as it forces all settings to default values. [issue filename] is the name of the CAPM software file being loaded into the controller.
  • #24: When the correct command line has been entered, details of the software to be loaded will be displayed. A message appears to ensure the Trip and Close switches are isolated before the software load continues.
  • #25: During the software load the Command Prompt screen will display the progress as an increasing percentage until 100% complete. The screen display will then change to advise that the software database is being downloaded. When the software load is complete, the Command Prompt screen will appear as above. The CAPM will restart after a delay of up to 3 seconds.
  • #26: A successful software download can be confirmed on the Switchgear Wear/General Details screen on the Operator Control Panel. This screen is in the System Status menu.
  • #27: Once it has been confirmed that the CAPM software has been downloaded successfully, the switchgear configuration that was saved earlier can be reloaded into the controller.
  • #28: Once the switchgear configuration has been reloaded into the controller, a comparison can be done to check that the on-line and off-line files are the same. To do a comparison, WSOS firstly reads the configuration from the controller and then compares it with the off-line file already on the PC. If any differences are found, they will be displayed by WSOS as above.