The Dräger Polytron 2 XP Tox is an explosion proof gas detector 
for continuous monitoring of toxic gases and oxygen in ambient 
air. The transmitter converts the signal from an electrochemical 
sensor to a 4 to 20 mA analog or HART® or RS 485 digital 
signal output. The unit is designed for one-man calibration, and 
offers a variety of diagnostics and self test features. 
The configuration and calibration of the 
transmitter is menu guided and easy to 
perform, using either the infrared remote 
control, the built-in push buttons, or a 
HART® hand held terminal. With the 
optional relays, Dräger Polytron 2 XP Tox 
can be operated as ‘stand alone’ unit. 
EASY TO INSTALL 
The enclosure provides two mounting 
holes. For easy wiring, the electronics is 
enclosed in a ‘bucket’, and can be pulled 
out as one unit, held by a tether. The three 
wire cable, fed through a sealed conduit, 
is terminated in a pluggable connector at 
the printed circuit board. 
ONE MAN CALIBRATION 
All setup and maintenance can be 
performed without opening the transmitter 
or declassifying the hazardous area. An 
infrared remote control, beaming through 
the window, gives full access to the menu 
and calibration procedure. The menu can 
also be accessed using the built-in push 
buttons or a HART® hand held terminal. 
All menu items and messages are 
displayed in plain English. Other, user 
selectable languages are French, Spanish 
and German. 
DRÄGERSENSOR TECHNOLOGY 
High sensitivity, long term stability and no 
false alarms are the hallmark of the new 
and improved third generation of sensors. 
Sensors are the keystones of any gas 
detection system. Fastest response to 
the target gas combined with minimal 
interference by other gases or environ - 
mental influences (no false alarms) as well as 
the sensor life-time determine the reliability 
and the operating cost of a system. 
STAND ALONE SYSTEM 
With the three built-in relays, Dräger 
Polytron 2 XP Tox can be used as 
an independent stand alone unit. Two 
adjustable gas alarm levels and a fault 
alarm make it convenient to switch 
warning devices on-site, without having to 
run cables back and forth to a central 
controller. The sensor signal can still 
be transmitted using either the 4 to 
20 mA, HART® or RS 485 signal output. 
FEATURES/BENEFITS 
– DrägerSensor® technology 
– Fast, accurate response 
– Non-intrusive calibration 
– Backlit LC-Display 
– 4 to 20mA, HART®, RS 485 interface 
– Multidrop capability, reduced wiring costs 
– Optional relays on board 
– ATEX, UL and CSA approved 
ST-1413-2006 
Dräger Polytron 2 XP Tox 
Electrochemical sensor to 
detect toxic gases and oxygen. 
ST-1392-2006
02 | DRÄGER POLYTRON 2 XP TOX 
TECHNICAL DATA 
Type Explosion proof transmitter 
Gases and Ranges Toxic gases and oxygen in user selectable ranges (see sensor data sheet) 
Display Backlit LCD; 2 lines, 20 characters Menu structure and messages in real text 
Signal Output Analog Normal operation 4 to 20 mA 
Warning, configurable fault signal every 10 s for 1 s, or off; user programmable 
Maintenance 4 ± 1 mA 1 Hz modulation, or steady; user programmable 
Fault < 1.2 mA 
Digital HART®, RS 485 
Relays (optional) Two alarm relays, one fault relay SPDT; user programmable 
Rating: 5A 230 VAC, 5A 30 VDC 
Supply Voltage 10 to 32 VDC, 3-wire 
Ambient Conditions Temperature – 40 to + 150 °F / – 40 to + 65 °C 
Pressure 20.7 to 38.4 inch Hg / 700 to 1300 mbar 
Humidity 0 to 100 %RH (see sensor data sheet) 
Enclosure NEMA 4X & 7, IP 66; 3/4" NPT female conduit entry 
Size (h x w x d, approx.) 10 3/4" x 5" x 5" / 275 x 130 x 130 mm 
Weight (approx.) 5.3 lbs / 2.4 kg 
Approvals UL, CSA Class I, Div 1, Group B, C, D 
ATEX II 2G EEx d [ia] IIC T6/T4, II 3D IP66 T85°C; – 40 ≤ Tamb ≤ + 40 / + 65 °C 
CE-mark electromagnetic compatibility (directive 89/336/EEC) 
HART® is registered trademark of HCF, Austin, TX 
ORDER INFORMATION 
Dräger Polytron 2 XP Tox without sensor and relays; UL, CSA, ATEX version 45 43 070 
Dräger Polytron 2 XP Tox without sensor, with relays; UL, CSA, ATEX version 45 43 200 
Tel: +44 (0)191 490 1547 
Fax: +44 (0)191 477 5371 
Email: northernsales@thorneandderrick.co.uk 
Website: www.heattracing.co.uk 
www.thorneanderrick.co.uk

More Related Content

PDF
Drager REGARD-1 Fixed Gas Detector Control System - Spec Sheet
PDF
System Sensor APA151
PDF
Drager Polytron 7500 Fixed Gas Detector - Spec Sheet
PDF
TDLS8000 Tunable Diode Laser Spectrometer
PDF
NIVELCO EasyTREK SP-500 Ultrasonic Level Transmitters for Liquids
PDF
ECD Model T23 pH, ORP, Specific Ion, Dissolved Oxygen, Conduc􏰁tivity Transmit...
PDF
Drager QuadGard Fixed Gas Detector Control System - Spec Sheet
PDF
United Electric One Series Safety Transmitter
Drager REGARD-1 Fixed Gas Detector Control System - Spec Sheet
System Sensor APA151
Drager Polytron 7500 Fixed Gas Detector - Spec Sheet
TDLS8000 Tunable Diode Laser Spectrometer
NIVELCO EasyTREK SP-500 Ultrasonic Level Transmitters for Liquids
ECD Model T23 pH, ORP, Specific Ion, Dissolved Oxygen, Conduc􏰁tivity Transmit...
Drager QuadGard Fixed Gas Detector Control System - Spec Sheet
United Electric One Series Safety Transmitter

What's hot (18)

PDF
Labguard 3D Technical brochure
PDF
Rotronic PF4 Fast Response Differential Pressure & Temperature Measurement Tr...
PDF
Honeywell 5808w3-data-sheet
PDF
System Sensor 2WTR-B Data Sheet
PDF
Get 4 channel, 8 channel, 16 channel temperature scanner - Canopus Instruments
PDF
Rotronic HF5 Humidity & Temperature Transmitter - Spec Sheet
PDF
Raritan Environment Sensors for Data Centers
PDF
Thermal Dispersion Mass Flow Measurement
PDF
Process Signal Isolated Transmitters, 4-20 ma
PDF
Fixed installation industrial gas monitors
PDF
PH/ORP Transmitter PH-100S
PDF
Series One Safety Transmitter, Pressure and Temperature Switch
PDF
IM 42XX Series - Intelligent Monitoring System - Panel Mount. (Serial & 4-20m...
PDF
Honeywell is2560-spec-sheet
PDF
Manual de instalacion detector honeywell
PDF
Multi zone datasheet
PDF
Labkotec_Applications_guide_ENG_2015_net (002)
PDF
High frequency radar level meter zero902
Labguard 3D Technical brochure
Rotronic PF4 Fast Response Differential Pressure & Temperature Measurement Tr...
Honeywell 5808w3-data-sheet
System Sensor 2WTR-B Data Sheet
Get 4 channel, 8 channel, 16 channel temperature scanner - Canopus Instruments
Rotronic HF5 Humidity & Temperature Transmitter - Spec Sheet
Raritan Environment Sensors for Data Centers
Thermal Dispersion Mass Flow Measurement
Process Signal Isolated Transmitters, 4-20 ma
Fixed installation industrial gas monitors
PH/ORP Transmitter PH-100S
Series One Safety Transmitter, Pressure and Temperature Switch
IM 42XX Series - Intelligent Monitoring System - Panel Mount. (Serial & 4-20m...
Honeywell is2560-spec-sheet
Manual de instalacion detector honeywell
Multi zone datasheet
Labkotec_Applications_guide_ENG_2015_net (002)
High frequency radar level meter zero902
Ad

Similar to Drager Polytron 2 XP Tox Fixed Gas Detector - Spec Sheet (20)

PDF
Drager Polytron 5310 Fixed Gas Detector - Spec Sheet
PDF
Drager Polytron IR CO2 Fixed Gas Detector - Spec Sheet
PDF
Drager Polytron 8310 Fixed Gas Detector - Spec Sheet
PDF
Drager Polytron 5700 Fixed Gas Detector - Spec Sheet
PDF
Drager Polytron 5720 Fixed Gas Detector - Spec Sheet
PDF
Drager Polytron Pulsar Duct Mount Fixed Gas Detector - Spec Sheet
PDF
Drager Polytron IR Fixed Gas Detector - Spec Sheet
PDF
Drager Polytron 8720 Fixed Gas Detector - Spec Sheet
PDF
Drager Polytron Pulsar Fixed Gas Detectors - Spec Sheet
PDF
Drager Polytron 8000 Fixed Gas Detector - Spec Sheet
PDF
Drager Polytron 5200 Fixed Gas Detector - Spec Sheet
PDF
Drager PointGard 2000 Series Gas Detection System
PDF
Drager Flame 2300 - Fixed Flame Detector - Spec Sheet
PDF
Dräger Polytron 8700 Fixed Gas Detector - Spec Sheet
PDF
Dual Input Temperature Transmitters
PDF
Dräger Flame 1300 - Fixed Flame Detector - Spec Sheet
PDF
Drager Flame 1700 - Fixed Flame Detector - Spec Sheet
PDF
Drager Variogard 3200 CAT Fixed Gas Detector - Spec Sheet
PDF
Magnetrol Guide Wave Radar Level Transmitter For Hygienic Applications
PDF
Drager Regard 3900 Fixed Gas Detector Control System - Spec Sheet
Drager Polytron 5310 Fixed Gas Detector - Spec Sheet
Drager Polytron IR CO2 Fixed Gas Detector - Spec Sheet
Drager Polytron 8310 Fixed Gas Detector - Spec Sheet
Drager Polytron 5700 Fixed Gas Detector - Spec Sheet
Drager Polytron 5720 Fixed Gas Detector - Spec Sheet
Drager Polytron Pulsar Duct Mount Fixed Gas Detector - Spec Sheet
Drager Polytron IR Fixed Gas Detector - Spec Sheet
Drager Polytron 8720 Fixed Gas Detector - Spec Sheet
Drager Polytron Pulsar Fixed Gas Detectors - Spec Sheet
Drager Polytron 8000 Fixed Gas Detector - Spec Sheet
Drager Polytron 5200 Fixed Gas Detector - Spec Sheet
Drager PointGard 2000 Series Gas Detection System
Drager Flame 2300 - Fixed Flame Detector - Spec Sheet
Dräger Polytron 8700 Fixed Gas Detector - Spec Sheet
Dual Input Temperature Transmitters
Dräger Flame 1300 - Fixed Flame Detector - Spec Sheet
Drager Flame 1700 - Fixed Flame Detector - Spec Sheet
Drager Variogard 3200 CAT Fixed Gas Detector - Spec Sheet
Magnetrol Guide Wave Radar Level Transmitter For Hygienic Applications
Drager Regard 3900 Fixed Gas Detector Control System - Spec Sheet
Ad

More from Thorne & Derrick UK (20)

PDF
Marechal Electric - Plugs & Sockets (Industrial & Hazardous Area (Explosion P...
PDF
Rotronic Instruments Temperature, Humidity, Flow, Pressure & Carbon Dioxide M...
PDF
Dart Valley Systems Catalogue
PDF
Cistermiser Water Efficient Washroom Controls - Specification Catalogue 2016
PDF
Wolf - Hazardous Area Portable & Temporary Lighting - Brochure
PDF
VEGA – Level, Point Level & Pressure Measurement Sensors, Instruments & Trans...
PDF
Thermon – Heat Tracing Cables (Self Regulating, Power Limiting, Constant Watt...
PDF
SIRAI - Solenoid Valves (WRAS Approved) - Overview Catalogue
PDF
Sika Measuring Metering Calibration Instruments
PDF
SICK - Sensors & Sensor Solutions - Catalogue
PDF
Rotronic Instruments - Temperature, Humidity, Flow, Pressure & Carbon Dioxide...
PDF
Patol Analogue Linear Heat Detection Cable
PDF
Murco - Gas Detection (Refrigerant Gas Leak Detectors & Sensors) - Product Br...
PDF
MSA Gas Detectors – Portable & Fixed Gas Detection - Brochure
PDF
Flow Meters Micronics Portable Fixed Flow Meters Ultrasonic Clamp On
PDF
LMK Thermosafe Hazardous Area Drum & IBC Product Overview
PDF
Krohne Hazardous Area Process Instrumentation Meters Measurement - Product Ov...
PDF
Katronic - Ultrasonic Flow Measurement & Flowmeters - Product Brochure
PDF
Kamstrup - Heat Meters & Water Meters Ultrasonic (RHI Compliant MID Class 2 H...
PDF
Itron - Gas, Water & Heat Meters - Corporate Brochure
Marechal Electric - Plugs & Sockets (Industrial & Hazardous Area (Explosion P...
Rotronic Instruments Temperature, Humidity, Flow, Pressure & Carbon Dioxide M...
Dart Valley Systems Catalogue
Cistermiser Water Efficient Washroom Controls - Specification Catalogue 2016
Wolf - Hazardous Area Portable & Temporary Lighting - Brochure
VEGA – Level, Point Level & Pressure Measurement Sensors, Instruments & Trans...
Thermon – Heat Tracing Cables (Self Regulating, Power Limiting, Constant Watt...
SIRAI - Solenoid Valves (WRAS Approved) - Overview Catalogue
Sika Measuring Metering Calibration Instruments
SICK - Sensors & Sensor Solutions - Catalogue
Rotronic Instruments - Temperature, Humidity, Flow, Pressure & Carbon Dioxide...
Patol Analogue Linear Heat Detection Cable
Murco - Gas Detection (Refrigerant Gas Leak Detectors & Sensors) - Product Br...
MSA Gas Detectors – Portable & Fixed Gas Detection - Brochure
Flow Meters Micronics Portable Fixed Flow Meters Ultrasonic Clamp On
LMK Thermosafe Hazardous Area Drum & IBC Product Overview
Krohne Hazardous Area Process Instrumentation Meters Measurement - Product Ov...
Katronic - Ultrasonic Flow Measurement & Flowmeters - Product Brochure
Kamstrup - Heat Meters & Water Meters Ultrasonic (RHI Compliant MID Class 2 H...
Itron - Gas, Water & Heat Meters - Corporate Brochure

Recently uploaded (20)

PPTX
O2C Customer Invoices to Receipt V15A.pptx
PPTX
Modernising the Digital Integration Hub
PDF
DP Operators-handbook-extract for the Mautical Institute
PDF
sustainability-14-14877-v2.pddhzftheheeeee
PPTX
Chapter 5: Probability Theory and Statistics
PPT
Geologic Time for studying geology for geologist
PDF
Architecture types and enterprise applications.pdf
PPTX
Final SEM Unit 1 for mit wpu at pune .pptx
PPTX
MicrosoftCybserSecurityReferenceArchitecture-April-2025.pptx
PDF
STKI Israel Market Study 2025 version august
PDF
From MVP to Full-Scale Product A Startup’s Software Journey.pdf
PDF
1 - Historical Antecedents, Social Consideration.pdf
PDF
ENT215_Completing-a-large-scale-migration-and-modernization-with-AWS.pdf
PDF
WOOl fibre morphology and structure.pdf for textiles
PPT
What is a Computer? Input Devices /output devices
PDF
How ambidextrous entrepreneurial leaders react to the artificial intelligence...
PPTX
Benefits of Physical activity for teenagers.pptx
PDF
August Patch Tuesday
PPT
Module 1.ppt Iot fundamentals and Architecture
PDF
Univ-Connecticut-ChatGPT-Presentaion.pdf
O2C Customer Invoices to Receipt V15A.pptx
Modernising the Digital Integration Hub
DP Operators-handbook-extract for the Mautical Institute
sustainability-14-14877-v2.pddhzftheheeeee
Chapter 5: Probability Theory and Statistics
Geologic Time for studying geology for geologist
Architecture types and enterprise applications.pdf
Final SEM Unit 1 for mit wpu at pune .pptx
MicrosoftCybserSecurityReferenceArchitecture-April-2025.pptx
STKI Israel Market Study 2025 version august
From MVP to Full-Scale Product A Startup’s Software Journey.pdf
1 - Historical Antecedents, Social Consideration.pdf
ENT215_Completing-a-large-scale-migration-and-modernization-with-AWS.pdf
WOOl fibre morphology and structure.pdf for textiles
What is a Computer? Input Devices /output devices
How ambidextrous entrepreneurial leaders react to the artificial intelligence...
Benefits of Physical activity for teenagers.pptx
August Patch Tuesday
Module 1.ppt Iot fundamentals and Architecture
Univ-Connecticut-ChatGPT-Presentaion.pdf

Drager Polytron 2 XP Tox Fixed Gas Detector - Spec Sheet

  • 1. Dräger Polytron 2 XP Tox Fixed Gas Detector Tel: +44 (0)191 490 1547 Fax: +44 (0)191 477 5371 Email: northernsales@thorneandderrick.co.uk Website: www.heattracing.co.uk www.thorneanderrick.co.uk The Dräger Polytron 2 XP Tox is an explosion proof gas detector for continuous monitoring of toxic gases and oxygen in ambient air. The transmitter converts the signal from an electrochemical sensor to a 4 to 20 mA analog or HART® or RS 485 digital signal output. The unit is designed for one-man calibration, and offers a variety of diagnostics and self test features. The configuration and calibration of the transmitter is menu guided and easy to perform, using either the infrared remote control, the built-in push buttons, or a HART® hand held terminal. With the optional relays, Dräger Polytron 2 XP Tox can be operated as ‘stand alone’ unit. EASY TO INSTALL The enclosure provides two mounting holes. For easy wiring, the electronics is enclosed in a ‘bucket’, and can be pulled out as one unit, held by a tether. The three wire cable, fed through a sealed conduit, is terminated in a pluggable connector at the printed circuit board. ONE MAN CALIBRATION All setup and maintenance can be performed without opening the transmitter or declassifying the hazardous area. An infrared remote control, beaming through the window, gives full access to the menu and calibration procedure. The menu can also be accessed using the built-in push buttons or a HART® hand held terminal. All menu items and messages are displayed in plain English. Other, user selectable languages are French, Spanish and German. DRÄGERSENSOR TECHNOLOGY High sensitivity, long term stability and no false alarms are the hallmark of the new and improved third generation of sensors. Sensors are the keystones of any gas detection system. Fastest response to the target gas combined with minimal interference by other gases or environ - mental influences (no false alarms) as well as the sensor life-time determine the reliability and the operating cost of a system. STAND ALONE SYSTEM With the three built-in relays, Dräger Polytron 2 XP Tox can be used as an independent stand alone unit. Two adjustable gas alarm levels and a fault alarm make it convenient to switch warning devices on-site, without having to run cables back and forth to a central controller. The sensor signal can still be transmitted using either the 4 to 20 mA, HART® or RS 485 signal output. FEATURES/BENEFITS – DrägerSensor® technology – Fast, accurate response – Non-intrusive calibration – Backlit LC-Display – 4 to 20mA, HART®, RS 485 interface – Multidrop capability, reduced wiring costs – Optional relays on board – ATEX, UL and CSA approved ST-1413-2006 Dräger Polytron 2 XP Tox Electrochemical sensor to detect toxic gases and oxygen. ST-1392-2006
  • 2. 02 | DRÄGER POLYTRON 2 XP TOX TECHNICAL DATA Type Explosion proof transmitter Gases and Ranges Toxic gases and oxygen in user selectable ranges (see sensor data sheet) Display Backlit LCD; 2 lines, 20 characters Menu structure and messages in real text Signal Output Analog Normal operation 4 to 20 mA Warning, configurable fault signal every 10 s for 1 s, or off; user programmable Maintenance 4 ± 1 mA 1 Hz modulation, or steady; user programmable Fault < 1.2 mA Digital HART®, RS 485 Relays (optional) Two alarm relays, one fault relay SPDT; user programmable Rating: 5A 230 VAC, 5A 30 VDC Supply Voltage 10 to 32 VDC, 3-wire Ambient Conditions Temperature – 40 to + 150 °F / – 40 to + 65 °C Pressure 20.7 to 38.4 inch Hg / 700 to 1300 mbar Humidity 0 to 100 %RH (see sensor data sheet) Enclosure NEMA 4X & 7, IP 66; 3/4" NPT female conduit entry Size (h x w x d, approx.) 10 3/4" x 5" x 5" / 275 x 130 x 130 mm Weight (approx.) 5.3 lbs / 2.4 kg Approvals UL, CSA Class I, Div 1, Group B, C, D ATEX II 2G EEx d [ia] IIC T6/T4, II 3D IP66 T85°C; – 40 ≤ Tamb ≤ + 40 / + 65 °C CE-mark electromagnetic compatibility (directive 89/336/EEC) HART® is registered trademark of HCF, Austin, TX ORDER INFORMATION Dräger Polytron 2 XP Tox without sensor and relays; UL, CSA, ATEX version 45 43 070 Dräger Polytron 2 XP Tox without sensor, with relays; UL, CSA, ATEX version 45 43 200 Tel: +44 (0)191 490 1547 Fax: +44 (0)191 477 5371 Email: northernsales@thorneandderrick.co.uk Website: www.heattracing.co.uk www.thorneanderrick.co.uk