Agenda
                            ● Present State of Affairs, Glimpse of the Future for
                              Data Center Power Requirements.

                            ● Efficiency Improvements and Path to Savings

                            ● Higher Voltage Options for Data Center Distribution




APC by Schneider Electric
IT Changes and Mechanical/Electrical Load Impacts




APC by Schneider Electric
High Density Computing

                                          35
            Per Rack Power Density (KW)



                                          30
                                          25               Max per-rack IT Load
                                          20
                                          15
                                                                                   Data Center rated
                                          10                                      rack power capacity
                                           5
                                           0

                                                                     Year
                                               IT Loads are greatly exceeding rated capacity!
APC by Schneider Electric
Needs for the Future Now!
                            ● Support for Higher Density Loads.
                               ● High Density Zones
                               ● kW per Rack vs Watts per Ft2
                            ● Higher Overall Building Efficiency.
                               ● Improved Efficiency of Every Aspect of Data Center
                                 Power Consumption.
                            ● Green Solutions.
                               ● Reduced Environmental Impact
                               ● Reduce – Recycle - Reuse
                            ● Rapid Deployment and Relocation.
                               ● Changing Face of Economy
                                   • Mergers & Acquisitions
                                   • Compaction, Consolidation




APC by Schneider Electric
A standardized way to specify density                                 Specifying
                                                                          Density



Traditional                 Same 500 kW data center – but different “average
way                         density” depending on how calculated:

                                            746 watts/ft2
                                                             Ambiguous
                                            179 watts/ft2    • Include access area around
                                                              racks?
                                                             • Include back-room area?
                                            119 watts/ft2
                                                             • Consider total mains power
                                                              consumption ?
                                            189 watts/ft2




White paper


      120

APC by Schneider Electric
A standardized way to specify density                                            Specifying
                                                                                     Density



Traditional                    Same 500 kW data center – but different “average
way                            density” depending on how calculated:

                                               746 watts/ft2
                                                                     Ambiguous
                                               179 watts/ft2         • Include access area around
                                                                      racks?
                                                                     • Include back-room area?
                                               119 watts/ft2
                                                                     • Consider total mains power
                                                                      consumption ?
                                               189 watts/ft2


                            A better way                            Total IT power
                                               5 kW/rack =            # of racks

                                                  ● Eliminates the ambiguities of     watts/ft2
White paper
                                                  ● Allows different densities for different areas
      120                                           of the data center

APC by Schneider Electric
1 Spread the load
      Cooling strategies:                                  2 Supplemental cooling
                                                            3 High-density zone
     High-density zone                                        4 Whole room




    ● A “mini data center”
      with its own cooling
    ● Contributes no heat to   ● Hot/cool air circulation localized within
      rest of data center
                                 the zone by short air paths and/or
    ● Works with existing        containment
      room-based cooling
                               ● Achieves optimal efficiency
APC by Schneider Electric
High Efficiency UPS
    ● Most UPS Manufacturers
      are Striving for Higher
      Efficiencies in Standard
      Designs Today.
    ● On-Line UPS modules
      available with efficiencies
      as high as 96% at 100%
      Load.
    ● Flatter Efficiency Curves At
      Lighter Loads.
    ● More “Right Sized”
      Designs.




APC by Schneider Electric
Efficiency Savings through Scalability
 ● Parallel for capacity or                                      ● Parallel for capacity or
   redundancy                                                      redundancy
 ● 4000 amps system bus                                          ● 4000 amps system bus
           ● 4 X 800 kVA/720 kW UPS                                   ● 2 X 1600 kW Scalable UPS
 ● Average load of 40 – 60%                                      ● Average load of 40 – 60%
 ● UPS load at 50-55% has                                        ● UPS sized to ~ 80% of load
   Efficiency ranges from 91%                                      with an efficiency of around
   to 94%                                                          97%
           ●     At a loading of 55%, a 2880 kW                       ●   At a loading of 1600 kW (50%
                 system (1600 kW load), with an                           system load), each module can be
                 efficiency of 91% will have kW                           initially populated to 1000 kW.
                 losses of 158 kW                                     ●   Each module, loaded to 80%, with
           ●     At a kWh rate of $0.07, 158 kW of                        an efficiency of 97% will have
                 losses translates to $96,886 per                         system kW losses of 49 kW.
                 year                                                 ●   At a kWh rate of $0.07, 49 kW of
                                                                          losses translates to $30,047 per
                                                                          year.




                     6 points of efficiency improvement saves $66,839 per year in electrical costs



APC by Schneider Electric
UPS Load vs. Capacity

                                            Day 1 Capacity for Day 1 Loads
           Day 2 Capacity for Day 1 Loads   Day 2 Capacity for Day 2 Loads




APC by Schneider Electric
Typical North American Data Center
     Power Distribution

 Standard Configuration Utilizes
  PDUs to Transform UPS voltage to
  Server Power Supply Voltages
        480 VAC, 3 Phase, 3 W + G to
         208Y/120 VAC.
        Overall Rating of PDUs Can be 1.5
         to 3 Times the System Rating.
 Even the Best PDUs Have
  Efficiency Losses Associated With
  Them.
 Weight and Footprint
  Considerations in the Data Center
  White Space.
 Heat Losses Associated with XFMR
 208Y/120 VAC. Five Conductors, A,
  B, C, N, G, Higher Amperage




APC by Schneider Electric
Typical 400 VAC Data Center
     Power Distribution

 400 VAC Configuration Utilizes no
  PDUs to Transform UPS voltage to
  Server Power Supply Voltages
        400Y/230 VAC, 3 Phase, 4 W + G
         to Rack.
        Distribution More Closely Sized to
         the System Rating.
        Single Autotransformer or 400 VAC
         UPS System can be used.
 Greatly Reduced Weight and
  Footprint Considerations in the
  Data Center White Space.
 No or Reduced XFMR Heat Losses
 400Y/230 VAC. Five Conductors, A,
  B, C, N, G, Lower Amperage




APC by Schneider Electric
Questions?




APC by Schneider Electric

More Related Content

PDF
神州数码 Jason pan future_clouddatacenterv2
PPTX
Integrated Power Systems Product Overview
PDF
Trilogy - Henk Groenendijk
PDF
Panasonic Pt Lb3 Ea2
PPTX
3 8 12 Overview Of New Products Pat
PPTX
Schneider Presentation Seattle 2011
PDF
Eco friendly hd-ds_wp_final
PPT
Power Point Data Centre Uk Limited Apc
神州数码 Jason pan future_clouddatacenterv2
Integrated Power Systems Product Overview
Trilogy - Henk Groenendijk
Panasonic Pt Lb3 Ea2
3 8 12 Overview Of New Products Pat
Schneider Presentation Seattle 2011
Eco friendly hd-ds_wp_final
Power Point Data Centre Uk Limited Apc

What's hot (19)

PDF
Vacon NXP Common DC Bus products
PDF
WP88 Power and Cooling for POE
PDF
PDF
Nexus brosur (2)
PDF
Mk2420552059
PDF
Thottuvelil
PDF
AMD PowerTune Technology on Workstation Graphics
 
PDF
Eclipsall Energy NRG Series Spec Sheet 72 SE
PDF
AirWalk AW100 1x Ev Do
PPT
Residential Presentation 2010 Jan
PDF
PPT
Energy Focus Product Presentation
PDF
High-Brightness 9XX-nm Pumps with Wavelength Stabilization
PDF
PDF
PDF
Product Catlogue
PDF
Low power vlsi design ppt
PDF
PDF
Menachem Nathan - Downscaling Li-Ion Battery Technology
Vacon NXP Common DC Bus products
WP88 Power and Cooling for POE
Nexus brosur (2)
Mk2420552059
Thottuvelil
AMD PowerTune Technology on Workstation Graphics
 
Eclipsall Energy NRG Series Spec Sheet 72 SE
AirWalk AW100 1x Ev Do
Residential Presentation 2010 Jan
Energy Focus Product Presentation
High-Brightness 9XX-nm Pumps with Wavelength Stabilization
Product Catlogue
Low power vlsi design ppt
Menachem Nathan - Downscaling Li-Ion Battery Technology
Ad

Viewers also liked (20)

PDF
Hitachi Data Systems - Eagle Graduate Program
PPTX
Projetos i nova droga (1)
PDF
Presentation: Electric Metals (July 2011)
PDF
Speakers bio only
PDF
Gbr ge panel 07 26-12
PDF
Cong ty q net viet nam san pham qnet-qnet policies & procedures-hong kong -...
PDF
pg & e crop 2005 Proxy Statement
PDF
Chris Evans Resume February 2010
PDF
insights success fastest growing hr solution provider
PDF
Allied Academies Conference
PDF
Cleared Job Fair Job Seeker Handbook Feb 6, 2014, Tysons Corner, Va
PDF
Cleared Job Fair Job Seeker Handbook Nov 21, 2013, Crystal City, Va
PDF
2003 Caterpillar Inc. Annual Report
DOCX
INDUSTRIAL TRAINING REPORT
PDF
Shale gas operations - regulation of water and air impacts
PDF
News Release: Electric Metals
PDF
Americas petrogas presentation_october_15_2013
DOC
Rpp karakter
PPTX
Understanding the criminal court process as a victim
PPTX
Antecedentes históricos
Hitachi Data Systems - Eagle Graduate Program
Projetos i nova droga (1)
Presentation: Electric Metals (July 2011)
Speakers bio only
Gbr ge panel 07 26-12
Cong ty q net viet nam san pham qnet-qnet policies & procedures-hong kong -...
pg & e crop 2005 Proxy Statement
Chris Evans Resume February 2010
insights success fastest growing hr solution provider
Allied Academies Conference
Cleared Job Fair Job Seeker Handbook Feb 6, 2014, Tysons Corner, Va
Cleared Job Fair Job Seeker Handbook Nov 21, 2013, Crystal City, Va
2003 Caterpillar Inc. Annual Report
INDUSTRIAL TRAINING REPORT
Shale gas operations - regulation of water and air impacts
News Release: Electric Metals
Americas petrogas presentation_october_15_2013
Rpp karakter
Understanding the criminal court process as a victim
Antecedentes históricos
Ad

Similar to Kevin burke apc (20)

PDF
How to be green in the cloud
PPTX
Energy efficiency data center overview
PDF
Designing Next Generation Data Centres
PDF
IT Energy Waste - Green IT Expo 2009
PDF
400 VAC Power Distribution DCW 2010
PDF
Datacenter Revolution Dean Nelson, Sun
PDF
CIsco Energy Efficient Data Center
PDF
Calculating total power
PDF
An improved architecture for high efficiency, high-density data centers
PPT
Connectix Commercial Overview Dc Session 8 Using The Fear Model To Design...
PDF
Green dc (1)
PDF
Ems Brochure Dec. 1 2011
PDF
The Value Of BIM For Lifecycle Management in Critical Facilities When Time Qu...
PPTX
10 dos and donts of data centre design
PDF
Data Center 2.1
PDF
Integrated Facility Sub Systems
PDF
Best Practices for Achieving Return on Investment through Energy Efficient Co...
PDF
Koomeyondatacenterelectricityuse v9
PPTX
About Vicor Corporation
PDF
Micro-Modular Data Center infrastructure
How to be green in the cloud
Energy efficiency data center overview
Designing Next Generation Data Centres
IT Energy Waste - Green IT Expo 2009
400 VAC Power Distribution DCW 2010
Datacenter Revolution Dean Nelson, Sun
CIsco Energy Efficient Data Center
Calculating total power
An improved architecture for high efficiency, high-density data centers
Connectix Commercial Overview Dc Session 8 Using The Fear Model To Design...
Green dc (1)
Ems Brochure Dec. 1 2011
The Value Of BIM For Lifecycle Management in Critical Facilities When Time Qu...
10 dos and donts of data centre design
Data Center 2.1
Integrated Facility Sub Systems
Best Practices for Achieving Return on Investment through Energy Efficient Co...
Koomeyondatacenterelectricityuse v9
About Vicor Corporation
Micro-Modular Data Center infrastructure

More from Melanie Brandt (20)

PDF
Accelerating breakthrough business technologies in atlanta, tag featured spea...
PDF
Presentations seeking angel investment presentation (charlie paparelli)
PDF
Presentations seeking angel investment presentation (charlie paparelli)
PDF
Patent introduction and overview atlanta january 2014
PDF
Patent introduction and overview atlanta january 2014
PPTX
Wain kellum presentation
PDF
TAG infrastructure society logistics presentation by Page Siplon
PDF
So co water - energy tag ses 120716 final
PDF
Ras ses water energy july 26 2012 final
PDF
Open text tag_bpm 04-12 v3
PDF
Mc kenneys gatech
PDF
Mc kenneys gatech
PDF
Kevin burke apc
PDF
Yogendra joshi ga_tech
PDF
Wally phelps adaptiv_cool
PDF
Steve hammond nrel
PDF
Scott wilson hp_cfs
PDF
Ron hutchins ga_tech
PDF
Ortiz internap
PDF
Mc kenneys gatech
Accelerating breakthrough business technologies in atlanta, tag featured spea...
Presentations seeking angel investment presentation (charlie paparelli)
Presentations seeking angel investment presentation (charlie paparelli)
Patent introduction and overview atlanta january 2014
Patent introduction and overview atlanta january 2014
Wain kellum presentation
TAG infrastructure society logistics presentation by Page Siplon
So co water - energy tag ses 120716 final
Ras ses water energy july 26 2012 final
Open text tag_bpm 04-12 v3
Mc kenneys gatech
Mc kenneys gatech
Kevin burke apc
Yogendra joshi ga_tech
Wally phelps adaptiv_cool
Steve hammond nrel
Scott wilson hp_cfs
Ron hutchins ga_tech
Ortiz internap
Mc kenneys gatech

Recently uploaded (20)

PPTX
AI-assistance in Knowledge Collection and Curation supporting Safe and Sustai...
PDF
IFRS Notes in your pocket for study all the time
PDF
DOC-20250806-WA0002._20250806_112011_0000.pdf
PPTX
job Avenue by vinith.pptxvnbvnvnvbnvbnbmnbmbh
PPTX
Dragon_Fruit_Cultivation_in Nepal ppt.pptx
PDF
COST SHEET- Tender and Quotation unit 2.pdf
PDF
Reconciliation AND MEMORANDUM RECONCILATION
PDF
Katrina Stoneking: Shaking Up the Alcohol Beverage Industry
PDF
BsN 7th Sem Course GridNNNNNNNN CCN.pdf
PDF
pdfcoffee.com-opt-b1plus-sb-answers.pdfvi
PDF
Nidhal Samdaie CV - International Business Consultant
PDF
How to Get Funding for Your Trucking Business
PPT
Chapter four Project-Preparation material
PPTX
CkgxkgxydkydyldylydlydyldlyddolydyoyyU2.pptx
PDF
Deliverable file - Regulatory guideline analysis.pdf
PPTX
Belch_12e_PPT_Ch18_Accessible_university.pptx
PDF
MSPs in 10 Words - Created by US MSP Network
PDF
Training And Development of Employee .pdf
PPTX
Amazon (Business Studies) management studies
PPTX
Business Ethics - An introduction and its overview.pptx
AI-assistance in Knowledge Collection and Curation supporting Safe and Sustai...
IFRS Notes in your pocket for study all the time
DOC-20250806-WA0002._20250806_112011_0000.pdf
job Avenue by vinith.pptxvnbvnvnvbnvbnbmnbmbh
Dragon_Fruit_Cultivation_in Nepal ppt.pptx
COST SHEET- Tender and Quotation unit 2.pdf
Reconciliation AND MEMORANDUM RECONCILATION
Katrina Stoneking: Shaking Up the Alcohol Beverage Industry
BsN 7th Sem Course GridNNNNNNNN CCN.pdf
pdfcoffee.com-opt-b1plus-sb-answers.pdfvi
Nidhal Samdaie CV - International Business Consultant
How to Get Funding for Your Trucking Business
Chapter four Project-Preparation material
CkgxkgxydkydyldylydlydyldlyddolydyoyyU2.pptx
Deliverable file - Regulatory guideline analysis.pdf
Belch_12e_PPT_Ch18_Accessible_university.pptx
MSPs in 10 Words - Created by US MSP Network
Training And Development of Employee .pdf
Amazon (Business Studies) management studies
Business Ethics - An introduction and its overview.pptx

Kevin burke apc

  • 1. Power Delivery in Today’s Data Center On-Demand Architecture for Network Critical Physical Infrastructure Kevin P. Burke, P.E. Critical Systems Manager – Southeast Region Kevin.Burke@schneider-electric.com 704-821-0524 All content in this presentation is protected – © 2008 American Power Conversion Corporation
  • 2. Agenda ● Present State of Affairs, Glimpse of the Future for Data Center Power Requirements. ● Efficiency Improvements and Path to Savings ● Higher Voltage Options for Data Center Distribution APC by Schneider Electric
  • 3. IT Changes and Mechanical/Electrical Load Impacts APC by Schneider Electric
  • 4. High Density Computing 35 Per Rack Power Density (KW) 30 25 Max per-rack IT Load 20 15 Data Center rated 10 rack power capacity 5 0 Year IT Loads are greatly exceeding rated capacity! APC by Schneider Electric
  • 5. Needs for the Future Now! ● Support for Higher Density Loads. ● High Density Zones ● kW per Rack vs Watts per Ft2 ● Higher Overall Building Efficiency. ● Improved Efficiency of Every Aspect of Data Center Power Consumption. ● Green Solutions. ● Reduced Environmental Impact ● Reduce – Recycle - Reuse ● Rapid Deployment and Relocation. ● Changing Face of Economy • Mergers & Acquisitions • Compaction, Consolidation APC by Schneider Electric
  • 6. A standardized way to specify density Specifying Density Traditional Same 500 kW data center – but different “average way density” depending on how calculated: 746 watts/ft2 Ambiguous 179 watts/ft2 • Include access area around racks? • Include back-room area? 119 watts/ft2 • Consider total mains power consumption ? 189 watts/ft2 White paper 120 APC by Schneider Electric
  • 7. A standardized way to specify density Specifying Density Traditional Same 500 kW data center – but different “average way density” depending on how calculated: 746 watts/ft2 Ambiguous 179 watts/ft2 • Include access area around racks? • Include back-room area? 119 watts/ft2 • Consider total mains power consumption ? 189 watts/ft2 A better way Total IT power 5 kW/rack = # of racks ● Eliminates the ambiguities of watts/ft2 White paper ● Allows different densities for different areas 120 of the data center APC by Schneider Electric
  • 8. 1 Spread the load Cooling strategies: 2 Supplemental cooling 3 High-density zone High-density zone 4 Whole room ● A “mini data center” with its own cooling ● Contributes no heat to ● Hot/cool air circulation localized within rest of data center the zone by short air paths and/or ● Works with existing containment room-based cooling ● Achieves optimal efficiency APC by Schneider Electric
  • 9. High Efficiency UPS ● Most UPS Manufacturers are Striving for Higher Efficiencies in Standard Designs Today. ● On-Line UPS modules available with efficiencies as high as 96% at 100% Load. ● Flatter Efficiency Curves At Lighter Loads. ● More “Right Sized” Designs. APC by Schneider Electric
  • 10. Efficiency Savings through Scalability ● Parallel for capacity or ● Parallel for capacity or redundancy redundancy ● 4000 amps system bus ● 4000 amps system bus ● 4 X 800 kVA/720 kW UPS ● 2 X 1600 kW Scalable UPS ● Average load of 40 – 60% ● Average load of 40 – 60% ● UPS load at 50-55% has ● UPS sized to ~ 80% of load Efficiency ranges from 91% with an efficiency of around to 94% 97% ● At a loading of 55%, a 2880 kW ● At a loading of 1600 kW (50% system (1600 kW load), with an system load), each module can be efficiency of 91% will have kW initially populated to 1000 kW. losses of 158 kW ● Each module, loaded to 80%, with ● At a kWh rate of $0.07, 158 kW of an efficiency of 97% will have losses translates to $96,886 per system kW losses of 49 kW. year ● At a kWh rate of $0.07, 49 kW of losses translates to $30,047 per year. 6 points of efficiency improvement saves $66,839 per year in electrical costs APC by Schneider Electric
  • 11. UPS Load vs. Capacity Day 1 Capacity for Day 1 Loads Day 2 Capacity for Day 1 Loads Day 2 Capacity for Day 2 Loads APC by Schneider Electric
  • 12. Typical North American Data Center Power Distribution  Standard Configuration Utilizes PDUs to Transform UPS voltage to Server Power Supply Voltages  480 VAC, 3 Phase, 3 W + G to 208Y/120 VAC.  Overall Rating of PDUs Can be 1.5 to 3 Times the System Rating.  Even the Best PDUs Have Efficiency Losses Associated With Them.  Weight and Footprint Considerations in the Data Center White Space.  Heat Losses Associated with XFMR  208Y/120 VAC. Five Conductors, A, B, C, N, G, Higher Amperage APC by Schneider Electric
  • 13. Typical 400 VAC Data Center Power Distribution  400 VAC Configuration Utilizes no PDUs to Transform UPS voltage to Server Power Supply Voltages  400Y/230 VAC, 3 Phase, 4 W + G to Rack.  Distribution More Closely Sized to the System Rating.  Single Autotransformer or 400 VAC UPS System can be used.  Greatly Reduced Weight and Footprint Considerations in the Data Center White Space.  No or Reduced XFMR Heat Losses  400Y/230 VAC. Five Conductors, A, B, C, N, G, Lower Amperage APC by Schneider Electric