QUALIFICATION OF LC-MS
By
Ankush Ramrao sule
M. Pharmacy 1st
year
School of Pharmacy, Nanded
LIQUID CHROMATOGRAPHY
MASS SPECTROMETRY
•Liquid chromatography-mass spectrometry (LC/MS) is a
technique that uses liquid chromatography (or HPLC) with
the mass spectrometry.
•It is an analytical chemistry technique that combines the
physical separation capabilities of liquid chromatography
with the mass analysis capabilities of mass spectrometry.
PRINCIPLE
•The LC-MS technology involves use of an HPLC, wherein
individual components in a mixture are first separated
followed by ionization and separation of the ions on the
basis of their mass/charge ratio. The separated ions are
then directed to a photo multiplier tube detector, which
identifies and quantifies each ion. The ion source is an
important component in any MS analysis, as this basically
aids in efficient generation of ions for analysis. To ionize
intact molecules, the ion source could be APCI
(Atmospheric Pressure Chemical Ionization), ESI
(Electronspray Ionization), etc. to name a few popular
ones. The choice of ion source also depends on the
chemical nature of the analyte of interest i.e. polar or non-
polar.
Instrumentation of LCMS
1. Ion source, which can convert gas phase sample
molecules into ions.
Following are the most common ionization methods
:
i. Electrospray Ionization
ii. Atmospheric Pressure Chemical Ionization
iii. Atmospheric Pressure Photo-ionisation
Components of Mass Spectrometer :
Components of Mass Spectrometer :
2. Analyzer , where ions are separated according to their
mass-to-charge ratio by applying electromagnetic fields.
•Its task is to separate ions in terms of their mass-to charge
•ratio and to direct the beam of focused ions to the detector.
•The key performance parameters of an analyzer include;
(a) separation efficiency
(b) m/z measurement precision
(c) range of the m/z values measured
•There are following kinds of mass analyzers that can be used
in LC/MS : (a)
Quadrupole Analyzer, (b)
Time-of-Flight Analyzer, (c) Ion
Trap Analyzer
Components of Mass Spectrometer :
3. Detectors :
The detector is used to count the ions emergent from
the mass analyzer, and may also amplify the signal
generated from each ion. Following are three different
kinds of detectors are used in Mass Spectrometry;
(a)Electron Multipliers (b)Dynolyte
Photomultiplier:
Tandem Mass Spectrometry
• Tandem mass spectrometry (MS/MS) is a system of two combined
analyzers of the same type or different types, characterized by high
separation efficiency.
• The ions produced by the source are separated in the first analyzer
(MS1). Ions with the selected m/z value reach the collision cell
where, depending on the analysis conditions, they undergo
dissociation or remain unchanged.
• In comparison with analysis using a single analyzer, tandem analysis
shows a considerable improvement in selectivity and considerably
increased sensitivity
OQ—Operational
Qualification
• Temperature accuracy and stability of column heater/cooler
• Holmium oxide wavelength scan (if applicable)
• Detector lamp intensity and wavelength accuracy
• Detector noise and drift
• Pump flow rate accuracy and repeatability
• High and low pressure shutdown accuracy
• Injector precision
• Detector linearity and sampleto-sample carryover
• Injection volume linearity
• Gradient composition accuracy
• Linear gradient tested using IPA and 0.5% Acetone/IPA
• Five step gradient tested using IPA and 0.5% Acetone/IPA
IQ—InstallationQualification
• Inventory of instruction manuals,
• components and serial numbers
• Installation verification
PQ—Performance
Qualification
• System performance and robustness
• Typically a 5 or 10 μL injection of a low
concentration sample, repeated five times
• Compare area count and retention time
deviations
Tests for HPLC Systems (Non-MSD)
Test Name Setpoints and
Parameters
Limits
Vacuum
Verification
N/A High vacuum min.: 8E-6 torr (any source)
High vacuum max.: 4E-5 torr (any source),
Scan
Verification
All used masses: ± 3.0 ppm (DSES, ES+AJST;
N/A for others)
Response
Linearity
Evaluated mass: 156
m/z Injection volume
on column: 20 ul*
Coefficient of determination (r2): ≥ 0.98000
(DSES, ES+AJST; N/A for others)
Tests for HPLC Systems (Non-MSD)
Test Name Setpoints and Parameters Limits
Injection
Precision
Evaluated mass: 156 m/z
Injection volume on
column: 20 ul*
Area RSD: ≤ 20.00 % (any source)
Height RSD: Not applicable (any
source)
Injection Carry
Over
Evaluated mass: 156 m/z
Injection volume on
column: 20 ul*
Area & height carry over ≤ 1.00 %
(DSES, ES+AJST;
N/A for others)
Signal to Noise
Evaluated mass: 156 m/z
Injection volume on
column: 20 ul*
Signal to noise: ≥ 10 (DSES,
ES+AJST; N/A for others)
Tests for Mass Spectrometer Detectors of
LCMS:
MSD 1. Vacuum Verification
Rationale: A stable, high vacuum is required for high-sensitivity mass
spectrometry.
Procedure: Multiple readings of the vacuum system are taken and an
automated comparison of these values to the known acceptable values is
made. Passing this test is a pre-requisite for the following tests.
MSD 2. Scan Verification
Rationale: Calibration of mass range is critical in qualitative mass
spectrometry.
Procedure: [Agilent LCMS] The built-in Agilent autotune is performed to
determine the proper calibration of the MSD and ensure that masses are
correctly reported across the entire mass range of the instrument. [Non-
Agilent LCMS] A manual tune is made where applicable.
Tests for Mass Spectrometer
Detectors of LCMS:
MSD 3. Response Linearity
Rationale: Knowledge of the response curve is critical for quantitative analysis.
Procedure: A sulfa drug mix standard of four sulfonamide drugs is injected into
the system at five concentrations representing a wide range for LCMS. The ions
monitored are appropriate to the system type. The calculated RSQ best-fit
regression line and plot of the response curve provides the statistics required to
evaluate the instrument’s overall response curve. This allows users to set
appropriate calibration ranges and limits in their quantitative application
methods.
MSD 4. Injection Precision
Rationale: System precision is critical for accuracy of quantitation. Autosampler
performance and MS ionization contribute to LCMS system precision.
Autosampler precision is challenged in the standard LC module tests using a UV
detector. A repeat precision test in MS mode further challenges the precision of
source ionization and MS detection. Procedure: A blank injection followed by six
repeat injections of the sulfa drug mix followed by a final blank injection are
made. The %RSD of the six injections is calculated to provide precision statistics.
Tests for Mass Spectrometer
Detectors of LCMS:
MSD 5. Carry Over
Rationale: Low carry over from a previous injection is critical for accuracy of
quantitative and reliability of qualitative analysis. Autosampler performance and
MSD condition contribute to LCMS carry over. Autosampler carry over is
challenged in the standard LC module tests using a UV detector. A repeat carry
over test in MS mode further challenges the full LCMS system carry over
performance.
Procedure: A blank injection followed by single injection of the highest
concentration standard followed by a blank injection. The last blank injection is
evaluated for carry over and the result expressed as a percentage of the value for
the standard injection.
MSD 6. Signal to Noise
Rationale: Sensitivity of MS detection is an important performance feature in
quantitative and qualitative analysis. A signal-to-noise value of representative
compounds and appropriate ions at known concentration provides sensitivity
statistics

More Related Content

PPTX
CHNS ANALYSIS AND ACCELERATED STABILITY STUDIES
PDF
Ich q3 d elemental impurities
PDF
Bioanalytical sample preparation
PPTX
Potential elemental impurities ,chns analyser
PPTX
ELEMENTAL ANALYSIS FOR MPHARM IST SEM
PPTX
Qualification of analytical instruments
PPTX
extraction of drug from biological matrix.pptx
CHNS ANALYSIS AND ACCELERATED STABILITY STUDIES
Ich q3 d elemental impurities
Bioanalytical sample preparation
Potential elemental impurities ,chns analyser
ELEMENTAL ANALYSIS FOR MPHARM IST SEM
Qualification of analytical instruments
extraction of drug from biological matrix.pptx

What's hot (20)

PPTX
Chiral separations by hplc
PPTX
Hplc parameters, factors affecting resolution
PPTX
Bioanalysis of drugs from biological samples
PPT
Analytical methods validation as per ich & usp
PDF
NABL Certification
DOCX
Bioanalytical samples preparation
PPTX
Immunoassay and its appication
PPTX
Methods For Estimation Of Pesticide Residue in Milk
PPTX
Ion pair chromatography for pharmacy students
PPTX
Extractables-Leachables-An Intro
PPTX
Degradation and Degradant Characterization
PPTX
Seminar on elemental impurities by prakash
PPT
Instrumentation and application of LC-MS/MS in bioanalysis
PPT
Icp ms
PDF
Analytical method validation workshop
PPTX
C H N S ANALYSIS.pptx
PDF
Sitec Presentation 140915
PPT
THE CONCEPT OF TRACEABILITY IN LABORATORY MEDICINE - A TOOL FOR STANDARDISATION
PPTX
General considerations and method development in ce,
Chiral separations by hplc
Hplc parameters, factors affecting resolution
Bioanalysis of drugs from biological samples
Analytical methods validation as per ich & usp
NABL Certification
Bioanalytical samples preparation
Immunoassay and its appication
Methods For Estimation Of Pesticide Residue in Milk
Ion pair chromatography for pharmacy students
Extractables-Leachables-An Intro
Degradation and Degradant Characterization
Seminar on elemental impurities by prakash
Instrumentation and application of LC-MS/MS in bioanalysis
Icp ms
Analytical method validation workshop
C H N S ANALYSIS.pptx
Sitec Presentation 140915
THE CONCEPT OF TRACEABILITY IN LABORATORY MEDICINE - A TOOL FOR STANDARDISATION
General considerations and method development in ce,
Ad

Similar to LCMS (20)

PDF
GC -MS/MS and LC MS/MS
PPTX
PPTX
Hyphenated techniques(GC-MS/MS, LC-MS/MS, HPTLC-MS)
PPTX
Qualification of HPLC & LCMS.pptxfjddjdjdhdjdjj
PPTX
Qualification of HPLC & LCMS.pptdjdjdjdjfjkfx
PPTX
PPTX
Degradation Analysis Using LC-MS/MS
PPT
Powerful tool for drug discovery and development.ppt
PPTX
Aadrsh kumar tiwari bbau
PDF
"Neurotech seminar" on Mass Spectrometry
PPTX
LIQUID CHROMETOGRAPHY MASS SPECTROMETRY.
PPTX
Hyphenated Chromatography Techniques in Analysis
PPTX
liquid chromatography - mass spectroscopy (LC-MS)
PPTX
High Resolution Mass Spectrometry Solutions for.pptx
PPTX
PDF
Chap3 1
PPTX
GCMS & LCMS
PPTX
Gas chromatography mass spectrometry (GC-MS)
PDF
gaschromatography-massspectrometrygc-ms-191115202105.pdf
GC -MS/MS and LC MS/MS
Hyphenated techniques(GC-MS/MS, LC-MS/MS, HPTLC-MS)
Qualification of HPLC & LCMS.pptxfjddjdjdhdjdjj
Qualification of HPLC & LCMS.pptdjdjdjdjfjkfx
Degradation Analysis Using LC-MS/MS
Powerful tool for drug discovery and development.ppt
Aadrsh kumar tiwari bbau
"Neurotech seminar" on Mass Spectrometry
LIQUID CHROMETOGRAPHY MASS SPECTROMETRY.
Hyphenated Chromatography Techniques in Analysis
liquid chromatography - mass spectroscopy (LC-MS)
High Resolution Mass Spectrometry Solutions for.pptx
Chap3 1
GCMS & LCMS
Gas chromatography mass spectrometry (GC-MS)
gaschromatography-massspectrometrygc-ms-191115202105.pdf
Ad

More from Mohammad Ahmed Khan (10)

PPT
commonly used Terminology in pharmacology.ppt
PPTX
Examples of Simulation Lab Presentation.pptx
PPTX
Pharmacology of Anti - fungal Drugs .pptx
PPTX
sympathomimeticdrugsppt-210519082222 (1).pptx
PPTX
Common Laboratory 1 Equipments used in Experimental Pharmacology
PPTX
5-HT (1).pptx
PPT
GenAnaesth.ppt
PPTX
common_Lab_animal_and_breeding_colonies-1.pptx
PPTX
acute toxicity.pptx
PDF
Streptomycin
commonly used Terminology in pharmacology.ppt
Examples of Simulation Lab Presentation.pptx
Pharmacology of Anti - fungal Drugs .pptx
sympathomimeticdrugsppt-210519082222 (1).pptx
Common Laboratory 1 Equipments used in Experimental Pharmacology
5-HT (1).pptx
GenAnaesth.ppt
common_Lab_animal_and_breeding_colonies-1.pptx
acute toxicity.pptx
Streptomycin

Recently uploaded (20)

PPTX
Taita Taveta Laboratory Technician Workshop Presentation.pptx
PPTX
cpcsea ppt.pptxssssssssssssssjjdjdndndddd
PPTX
ECG_Course_Presentation د.محمد صقران ppt
PPTX
C1 cut-Methane and it's Derivatives.pptx
PPT
protein biochemistry.ppt for university classes
PDF
Unveiling a 36 billion solar mass black hole at the centre of the Cosmic Hors...
PPTX
2. Earth - The Living Planet earth and life
PDF
SEHH2274 Organic Chemistry Notes 1 Structure and Bonding.pdf
PDF
Sciences of Europe No 170 (2025)
PDF
. Radiology Case Scenariosssssssssssssss
PPTX
ognitive-behavioral therapy, mindfulness-based approaches, coping skills trai...
PDF
CAPERS-LRD-z9:AGas-enshroudedLittleRedDotHostingaBroad-lineActive GalacticNuc...
PPT
6.1 High Risk New Born. Padetric health ppt
PPTX
2Systematics of Living Organisms t-.pptx
PDF
Assessment of environmental effects of quarrying in Kitengela subcountyof Kaj...
PDF
Mastering Bioreactors and Media Sterilization: A Complete Guide to Sterile Fe...
PPTX
neck nodes and dissection types and lymph nodes levels
PPTX
TOTAL hIP ARTHROPLASTY Presentation.pptx
PDF
Biophysics 2.pdffffffffffffffffffffffffff
PPTX
Introduction to Fisheries Biotechnology_Lesson 1.pptx
Taita Taveta Laboratory Technician Workshop Presentation.pptx
cpcsea ppt.pptxssssssssssssssjjdjdndndddd
ECG_Course_Presentation د.محمد صقران ppt
C1 cut-Methane and it's Derivatives.pptx
protein biochemistry.ppt for university classes
Unveiling a 36 billion solar mass black hole at the centre of the Cosmic Hors...
2. Earth - The Living Planet earth and life
SEHH2274 Organic Chemistry Notes 1 Structure and Bonding.pdf
Sciences of Europe No 170 (2025)
. Radiology Case Scenariosssssssssssssss
ognitive-behavioral therapy, mindfulness-based approaches, coping skills trai...
CAPERS-LRD-z9:AGas-enshroudedLittleRedDotHostingaBroad-lineActive GalacticNuc...
6.1 High Risk New Born. Padetric health ppt
2Systematics of Living Organisms t-.pptx
Assessment of environmental effects of quarrying in Kitengela subcountyof Kaj...
Mastering Bioreactors and Media Sterilization: A Complete Guide to Sterile Fe...
neck nodes and dissection types and lymph nodes levels
TOTAL hIP ARTHROPLASTY Presentation.pptx
Biophysics 2.pdffffffffffffffffffffffffff
Introduction to Fisheries Biotechnology_Lesson 1.pptx

LCMS

  • 1. QUALIFICATION OF LC-MS By Ankush Ramrao sule M. Pharmacy 1st year School of Pharmacy, Nanded
  • 2. LIQUID CHROMATOGRAPHY MASS SPECTROMETRY •Liquid chromatography-mass spectrometry (LC/MS) is a technique that uses liquid chromatography (or HPLC) with the mass spectrometry. •It is an analytical chemistry technique that combines the physical separation capabilities of liquid chromatography with the mass analysis capabilities of mass spectrometry.
  • 3. PRINCIPLE •The LC-MS technology involves use of an HPLC, wherein individual components in a mixture are first separated followed by ionization and separation of the ions on the basis of their mass/charge ratio. The separated ions are then directed to a photo multiplier tube detector, which identifies and quantifies each ion. The ion source is an important component in any MS analysis, as this basically aids in efficient generation of ions for analysis. To ionize intact molecules, the ion source could be APCI (Atmospheric Pressure Chemical Ionization), ESI (Electronspray Ionization), etc. to name a few popular ones. The choice of ion source also depends on the chemical nature of the analyte of interest i.e. polar or non- polar.
  • 5. 1. Ion source, which can convert gas phase sample molecules into ions. Following are the most common ionization methods : i. Electrospray Ionization ii. Atmospheric Pressure Chemical Ionization iii. Atmospheric Pressure Photo-ionisation Components of Mass Spectrometer :
  • 6. Components of Mass Spectrometer : 2. Analyzer , where ions are separated according to their mass-to-charge ratio by applying electromagnetic fields. •Its task is to separate ions in terms of their mass-to charge •ratio and to direct the beam of focused ions to the detector. •The key performance parameters of an analyzer include; (a) separation efficiency (b) m/z measurement precision (c) range of the m/z values measured •There are following kinds of mass analyzers that can be used in LC/MS : (a) Quadrupole Analyzer, (b) Time-of-Flight Analyzer, (c) Ion Trap Analyzer
  • 7. Components of Mass Spectrometer : 3. Detectors : The detector is used to count the ions emergent from the mass analyzer, and may also amplify the signal generated from each ion. Following are three different kinds of detectors are used in Mass Spectrometry; (a)Electron Multipliers (b)Dynolyte Photomultiplier:
  • 8. Tandem Mass Spectrometry • Tandem mass spectrometry (MS/MS) is a system of two combined analyzers of the same type or different types, characterized by high separation efficiency. • The ions produced by the source are separated in the first analyzer (MS1). Ions with the selected m/z value reach the collision cell where, depending on the analysis conditions, they undergo dissociation or remain unchanged. • In comparison with analysis using a single analyzer, tandem analysis shows a considerable improvement in selectivity and considerably increased sensitivity
  • 9. OQ—Operational Qualification • Temperature accuracy and stability of column heater/cooler • Holmium oxide wavelength scan (if applicable) • Detector lamp intensity and wavelength accuracy • Detector noise and drift • Pump flow rate accuracy and repeatability • High and low pressure shutdown accuracy • Injector precision • Detector linearity and sampleto-sample carryover • Injection volume linearity • Gradient composition accuracy • Linear gradient tested using IPA and 0.5% Acetone/IPA • Five step gradient tested using IPA and 0.5% Acetone/IPA
  • 10. IQ—InstallationQualification • Inventory of instruction manuals, • components and serial numbers • Installation verification
  • 11. PQ—Performance Qualification • System performance and robustness • Typically a 5 or 10 μL injection of a low concentration sample, repeated five times • Compare area count and retention time deviations
  • 12. Tests for HPLC Systems (Non-MSD) Test Name Setpoints and Parameters Limits Vacuum Verification N/A High vacuum min.: 8E-6 torr (any source) High vacuum max.: 4E-5 torr (any source), Scan Verification All used masses: ± 3.0 ppm (DSES, ES+AJST; N/A for others) Response Linearity Evaluated mass: 156 m/z Injection volume on column: 20 ul* Coefficient of determination (r2): ≥ 0.98000 (DSES, ES+AJST; N/A for others)
  • 13. Tests for HPLC Systems (Non-MSD) Test Name Setpoints and Parameters Limits Injection Precision Evaluated mass: 156 m/z Injection volume on column: 20 ul* Area RSD: ≤ 20.00 % (any source) Height RSD: Not applicable (any source) Injection Carry Over Evaluated mass: 156 m/z Injection volume on column: 20 ul* Area & height carry over ≤ 1.00 % (DSES, ES+AJST; N/A for others) Signal to Noise Evaluated mass: 156 m/z Injection volume on column: 20 ul* Signal to noise: ≥ 10 (DSES, ES+AJST; N/A for others)
  • 14. Tests for Mass Spectrometer Detectors of LCMS: MSD 1. Vacuum Verification Rationale: A stable, high vacuum is required for high-sensitivity mass spectrometry. Procedure: Multiple readings of the vacuum system are taken and an automated comparison of these values to the known acceptable values is made. Passing this test is a pre-requisite for the following tests. MSD 2. Scan Verification Rationale: Calibration of mass range is critical in qualitative mass spectrometry. Procedure: [Agilent LCMS] The built-in Agilent autotune is performed to determine the proper calibration of the MSD and ensure that masses are correctly reported across the entire mass range of the instrument. [Non- Agilent LCMS] A manual tune is made where applicable.
  • 15. Tests for Mass Spectrometer Detectors of LCMS: MSD 3. Response Linearity Rationale: Knowledge of the response curve is critical for quantitative analysis. Procedure: A sulfa drug mix standard of four sulfonamide drugs is injected into the system at five concentrations representing a wide range for LCMS. The ions monitored are appropriate to the system type. The calculated RSQ best-fit regression line and plot of the response curve provides the statistics required to evaluate the instrument’s overall response curve. This allows users to set appropriate calibration ranges and limits in their quantitative application methods. MSD 4. Injection Precision Rationale: System precision is critical for accuracy of quantitation. Autosampler performance and MS ionization contribute to LCMS system precision. Autosampler precision is challenged in the standard LC module tests using a UV detector. A repeat precision test in MS mode further challenges the precision of source ionization and MS detection. Procedure: A blank injection followed by six repeat injections of the sulfa drug mix followed by a final blank injection are made. The %RSD of the six injections is calculated to provide precision statistics.
  • 16. Tests for Mass Spectrometer Detectors of LCMS: MSD 5. Carry Over Rationale: Low carry over from a previous injection is critical for accuracy of quantitative and reliability of qualitative analysis. Autosampler performance and MSD condition contribute to LCMS carry over. Autosampler carry over is challenged in the standard LC module tests using a UV detector. A repeat carry over test in MS mode further challenges the full LCMS system carry over performance. Procedure: A blank injection followed by single injection of the highest concentration standard followed by a blank injection. The last blank injection is evaluated for carry over and the result expressed as a percentage of the value for the standard injection. MSD 6. Signal to Noise Rationale: Sensitivity of MS detection is an important performance feature in quantitative and qualitative analysis. A signal-to-noise value of representative compounds and appropriate ions at known concentration provides sensitivity statistics