IJRET: International Journal of Research in Engineering and Technology ISSN: 2319-1163
__________________________________________________________________________________________
Volume: 01 Issue: 03 | Nov-2012, Available @ http://www.ijret.org 474
MODIFIED DC-DC CONVERTER FOR HIGH INPUT VOLTAGE
APPLICATIONS
Battula.VeeraVasanthaRao1
, Sravanthi.Kantamaneni2
1
Assistant Professor, E.E.E Dept., 2
Assistant Professor, E.C.E Dept
veeravasantharao@gmail.com, 2
sravanthi.kantamneni@yahoo.com
Abstract:
This paper proposes a model for high input voltage applications using two fly-back converters. In this the components are arranged
by using integrated magnetic techniques. To reduce the voltage stresses the input components are connected in series and to obtain
the required output the output components are connected in parallel. The three cores of the fly-back transformers are air gaped to
reduce the current spikes which are caused due to coupling and the secondary side of the transformers are inversely coupled for
ripple cancellation. This is done by using a prototype which helps us to obtain output as we desired for certain input with certain
transformation ratio. The components used are IGBT’s, capacitors and fly-back transformers.
Keywords: Integrated magnetic techniques fly back converter, coupling, ripple reduction, interleaved operation.
----------------------------------------------------------------------*****---------------------------------------------------------------------
I. INTRODUCTION:
Integrated magnetic techniques combine transformers and
inductors into a single core in order to reduce the size and cost
of magnetic components in dc/dc converters. Principles of
modeling and designing integrated magnetic have been widely
published. Historically, integrated dc/dc converters were first
developed for Forward converters. However, recently
integrated magnetic full wave circuits have been extensively
studied. These full wave circuits have reported significant
benefits, including high efficiency, high power density and
low switch stress. Applications of these circuits are being
proposed in 30 W - 100 W ranges, and have great potential for
telecommunication power supplies. A “typical”2 integrated
magnetic full wave dc/dc converter, which uses a three-leg
magnetic core. This class of full wave integrated magnetic
circuit‟s exhibits a common character that there is no winding
on the inductor leg. Instead, the secondary windings play the
role of the equivalent Inductor winding, and hence, the
secondary windings must satisfy both power transfer and
current ripple restrictions for different operating stages. The
elimination of the inductor winding comes from the magnetic
integration methods, and, in applications, this is believed to
reduce the copper loss and simplify the transformer structure.
However, optimum transformer design must keep the balance
between copper loss, ferrite loss and total size. In integrated
magnetic transformers, the number of secondary winding turns
influences the number of primary winding turns, the magnetic
core size and the output current characteristics. This places a
burden on the secondary winding turn decision and
complicates the transformer design. As a result, the magnetic
core often needs to be specially designed and manufactured in
order to satisfy both output current ripple requirements and
flux density constraints. Using flyback converter this
integrated magnetic techniques are employed.It is equivalent
to that of a buck-boost converter, with the inductor split to
form a transformer . Therefore the operating principle of both
converters is very close:
When the switch is on, the primary of the transformer is
directly connected to the input voltage source. This results in
an increase of magnetic flux in the transformer. The voltage
across the secondary winding is negative, so the diode is
reverse-biased (i.e., blocked). The output capacitor supplies
energy to the output load. When the switch is off, the energy
stored in the transformer is transferred to the output of the
converter. The operation of storing energy in the transformer
before transferring to the output of the converter allows the
topology to easily generate multiple outputs with little
additional circuitry, although the output voltages have to be
able to match each other through the turns ratio.
This paper uses two fly-back converters which act as fly-back
transformers which are designed under a single magnetic core.
Earlier they designed a converter based on this concept. The
main features of that converter are
 Earlier designed a single magnetic core three limbed
transformer with center limb air gapped. So that the
current spikes can be reduced.
 The primary and secondary side of the transformer is
connected in parallelthe operation is similar to that of a
fly-back converter with two switches on the primary side
and two capacitors on the secondary side. The secondary
side is directly coupled.
IJRET: International Journal of Research in Engineering and Technology ISSN: 2319-1163
__________________________________________________________________________________________
Volume: 01 Issue: 03 | Nov-2012, Available @ http://www.ijret.org 475
Whereas coming to the modified converter the changes made
and the specified reasons for the changes are as discussed
below.
 Connecting the primary side in series reduces the voltage
stresses of the primary components. The primary switches
are rated at half of the corresponding voltage values in a
single Fly-back or a traditional full wave buck-boost
power converter.
 The on-resistance and cost of the primary switches are,
thus, significantly reduced. Alternatively, this implies that
for the same rated switches, the proposed converter can
handle twice the input voltage compared with the
converter.
 Interleaved operation with paralleled connection on the
secondary side keeps the benefits of ripple reduction as a
traditional full wave buck-boost power converter does.
 To satisfy a certain current ripple requirement,
magnetizing inductance can be reduced by means of
suitable inductor coupling design.
 Due to the mutual influence of the two coupled inductors
that is combined with the transformers, further current
ripple reduction can be achieved when compared with
interleaved Fly-back converters without coupling.
 Also, the amount of the magnetic components is reduced
by integrating the two transformers into one magnetic
core, although the efficiency of the new approach may not
be improved when compared with conventional discrete
interleaved Fly-backs.
 Current spike caused by the voltage mismatch between
the windings can be suppressed by gapping all the center
and outer legs. Compared with tight coupling, such as the
condition in a traditional full wave buck-boostpower
converter, gapping all the legs weakens the coupling
between the two Fly-backs‟ windings, and thus,reduces
the effect of the voltage mismatch. Between the two Fly-
backs‟ windings, and thus, reduces the effect of the
voltage mismatch.
The modified converter is as shown below which consists of
IGBT‟s which act as switches on the primary side,
thecapacitors help in the timing operation of the converter
depending on the intervals. And the secondary consists of
diodes D1 and D2 which are reversely coupled for the sake of
ripple reduction. And the operation of the converter is as
discussed below.
Figure representing the circuit model of the modified dc-dc
converter Operation principle
The main primaries switch and are the auxiliary switches,
which are connected with the reset windings to obtain active
clamp. Vc1, Vc2, Vc3 are the voltages across c1, c2, c3.
Capacitors Cr1 and Cr2 are the equivalent resonant capacitors
of q1, q2. c1, q1, t1, q3 and c3 are the primary side
components of one active-clamp forward, while the other
forward consists of c2, q2,t2, q4 and c3. The two forward
circuits share the clamping capacitor c3 so that the charge
balances of c1 and c2 are kept. Since the control signals of the
two channels have the same duty cycle, unbalanced voltage on
c1, c2 and can generate different magnetizing current to
charge the capacitors. Therefore, the two input voltages are
adjusted to a balanced value at steady state. Also, the two
channels share the freewheeling switch q7 and output inductor
L1on the secondary side. Therefore, there is no current sharing
problem.
The size of the output inductor is reduced due to interleaved
operation. One potential concern is the effect of the leakage
inductor between the primary winding and the active clamp
winding. The energy stored in the leakage inductor can
impose excessive voltage spikes on the switches. This leads to
higher voltage stress on the switches and should be taken into
IJRET: International Journal of Research in Engineering and Technology ISSN: 2319-1163
__________________________________________________________________________________________
Volume: 01 Issue: 03 | Nov-2012, Available @ http://www.ijret.org 476
account for design. Thus, transformers with tight coupling are
required. Also, effective snubber is helpful to reduce the
voltage stress. The following description explains the detailed
operation principle of the proposed topology.
In general, circuit operation can be qualitatively described
over several modes/intervals. The upper forward circuit
transfers energy to secondary side during time interval t0 –
t1.The under forward circuit transfer energy during interval t7
– t8. Interval t4 – t5 and interval t11 – t12 are utilized for the
freewheeling process of theoutput current. All the remaining
intervalsare transition intervals and are substantially smaller in
length than energy transfer or freewheeling time intervals.
Interval t0 – t14is defined as the switching period T1. The
lengths of t0 – t1 and t7 – t8 are defined as DT, which
represents the duty ratio, and thus, the duty ratio D will always
be less than one-half. The lengths of t1 – t4 and t8 – t11 are set
to a suitable value td, which is longer than the required
transition time t1 – t3 and t8 – t10. The length of t0 – t1 and t7
– t8 are defined as DT, which represents the duty ratio.
2. FLUX DISTRIBUTIONS ANALYSIS:
For the convenience of magnetic design, it is necessary to
providethe formulas for flux distributions. To prevent the
magneticcore from saturating, the peak values of the flux
densities in allthree legs should be keptbelow a specified
maximum valueTherefore, this section will discuss the
detailed calculation forboth the ac fluxes and dc fluxes in all
three legs. As a result, thepeak values of the fluxes are the sum
of the dc fluxes and half of the ac fluxes showsthe magnetic
reluctance circuit of the proposedtopology, assuming the
conditions of the two outer legs are symmetrical. Also, Fig
shows the flux path of in the core of transformer.Because of
the air gap, the center leg is no longer alow magnetic
reluctance path for the fluxes. The flux generated by each
winding in the outer legs can go through all threelegs. The
flux interaction between the windings affects the currentripple
and peak values of the flux densities Furthermore, following
figure shows the detailed equivalent magneticreluctance
circuit during each interval. The effect of the
correspondingwinding is removed when the current in the
windingis zero.
Figures a,b,c,d respectively shows the flux path in the core
Of which fig a represents flux path during the interval t0-t1
similarlyfig b during t1-t2, fig c during t2-t3 and fig d during
t3-t4. The equations corresponding to their flux paths and
intervals are
T0-T1: Фc= (Vin/2Np)-(V0/Ns)
T1-T2: Фc=- (2V0/Ns)
T2-T3: Фc= (Vin/2Np)-(V0/Ns)
T3-T4: Фc=- (2V0/Ns)
Thus by the analysis all the fluxes in the system i.e. both the
ac and dc fluxes obtained are
IJRET: International Journal of Research in Engineering and Technology ISSN: 2319-1163
__________________________________________________________________________________________
Volume: 01 Issue: 03 | Nov-2012, Available @ http://www.ijret.org 477
Total ac flux in the two outer limbs is obtained as
∆ф1= ∆ф2=V0(1-D)/Nsfs
The total ac flux in the center limb obtained as
∆фc=V0 (1-2D)/Nsfs
DC Flux:
Фc=ф1+ф2
= (Np1Ip1+Ns1Is1+Np2Ip2+Ns2Is2)(1/(R0+2Rc)
To avoid the saturation of the magnetic core, the peak value
ofthe flux densities of all three legs should be computed. The
peak value can be obtained by the sum of DC fluxes and half
of the total AC fluxes. By using the calculation of the current
ripple and the peakflux densities suitable magnetic core size
and the turnnumbers of the windings can be chosen to satisfy
the currentripple restrictions and the magnetic constraints.
3. SIMULATION AND RESULTS:
The Simulink model of the converter is as shown below. In
this dual converter two interleaved forward circuits are
connected in series on the primary side and in parallel on the
secondary side the two transformers share one low voltage
capacitor for clamping through auxiliary windings and
switches. Through the resonance between the magnetizing
inductors and equivalent capacitors of the switches during the
transition time, switching loss of the primary switches can be
reduced. Output current and voltage wave forms when firing
pulses from same firing circuit. When firing pulses are giving
from a single pulse generating circuit wave forms are shown
in graph here input voltage is 400V, output is 20V and current.
Fig-1: output current and voltage wave forms when firing
pulses from same firing circuit.
When firing pulses for individual switches is given from
different firing circuits the only difference is output voltage,
output current values are changed and in this input voltage is
same is same that is 400V.but output voltage is25V and output
current is 0.7A
Fig-2: output voltage and current wave forms when firing
pulses are from different firing circuits.
Specifically, the following differences are remarked when
compared with a traditional converter in.
1) The new approach connects the input of the two Fly backs
in series, while the traditional method connects the input in
parallel.
2) The proposed converter has three gaps in all legs. The
traditional converter only has one gap in the center leg.
3) The secondary windings are inversely coupled in the new
converter, and directly coupled in the traditional converter.
From the first difference, it can be concluded that the proposed
method has half of the voltage stress when compared with the
traditional method. According to the second and third
differences, the secondary windings of the traditional
converter are directly coupled with tight coupling. However,
for practicalcircuits, especially for this high voltage
application, switches cannot operate exactly simultaneously.
There is a voltage mismatch between the two secondary
windings. The voltage difference is applied to the leakage
inductance between the twowindings. Because the two outer
legs have low reluctances, and the center leg has a high
reluctance, the two secondary windings have good coupling
and small leakage inductance. Minor mismatch can lead to
high current spikes and resonance. On the other hand, the
secondary windings of the new converterare inversely coupled
with not so tight couplingsince all three legs are gapped. By
gapping all the three legs, a big leakage inductance between
the windings of the two
Transformers is obtained, since the flux generated by each
winding in the outer legs can go through all three legs (is
approximately equal to 1/3 when all the legs have gaps with
approximately same distances.) The large inductance value
can avoid high current spike when a voltage mismatch is
applied. Also, current ripple reduction can still be achieved
with suitable coupling design. We also remark that the
weakened coupling between the two transformers allows the
duty ratio to be greater than 50% in the propose circuit
IJRET: International Journal of Research in Engineering and Technology ISSN: 2319-1163
__________________________________________________________________________________________
Volume: 01 Issue: 03 | Nov-2012, Available @ http://www.ijret.org 478
CONCLUSIONS
The dual interleaved forward converter may be beneficial for
high current/ high power density designs. This converter
topology would be ideal for intermediate bus converters and
merchant power applications because the reduced input and
output capacitor ripple current reduces electrical stress on the
input and output capacitors. The inductor ripple current
cancellation of interleaving converters allows the design more
output capacitance, which in turn should reduce the design's
output capacitance requirements.
Interleaving techniques are adopted to reduce input/output
current or voltage ripples for converters with critical
conduction mode. This is useful for not only buck operation
and also for boosting purpose. In this study implements two
types of phase-shift control schemes for critical interleaved
boost PFC converters. Sub-harmonic oscillation phenomena
occur at high line voltage when one of them is adopted. So this
paper presents a quantitative analysis on the phenomena and
proposes a novel phase-shift control scheme.
REFERENCES:
[1] G. C. Hua and F. C. Lee, “Novel zero voltage transition
PWM converters,‟ in Proc. IEEE Power Electronspec.conf.,
1992, pp.55-61.
[2] J.G. Cho et al., “zero-voltage and zero-current-switching
full bridge PWM converter for high-power applications,‟
IEEE Trans. Power Electron., vol.11, pp.622-628, July 1996.
[3] T. Morimoto, shirakawa, O. Koudriavtsev, and M.
Nakaoka, ‟ zero-voltage zero current hybrid soft-switching
phase-shifted PWM dc-dc power converter for high power
applications, „in Proc.IEEE APEC‟00,New
Orleans,LA,Feb.2000,pp.104-110.
[4] R. Redl, N.O. Sokal, and L. Balogh, ” A novel soft-
switching full-bridge dc/dc converter: analysis, design
considerations, and experimental results at 1.5 KW, 100KHz,
” IEEE Trans.Power Electron., vol.6,pp.408-418, july 1996.
[5] H.J.Kim and H.J.Kim, „Active clamp forward converter
with MOSFET synchronous rectification,” in Proc. Power
Electronics Specialists conf., 1994, vol.2.pp.895-901.
[6] Y.K.Lo, T.S.Kao, and J.Y.Lin, “Analysis and design of an
interleaved active-clamping forwardconverter,
IEEEtRANS.lnd.Electron” vol.54, no.4, pp.2323-2332, Aug
2007.

More Related Content

PDF
ANALYSIS OF SOLID STATE TRANSFORMER WITH PERMANENT MAGNET SYNCHRONOUS GENERATOR
PPTX
Solid state transformer ppt
PDF
Comparison of an Isolated bidirectional Dc-Dc converter with and without a Fl...
PDF
Design of Half Bridge LLC Resonant Converter for Low Voltage Dc Applications
PDF
Solar Based Stand Alone High Performance Interleaved Boost Converter with Zvs...
PDF
A Comparative Study of Various AC-DC Converters for Low Voltage Energy Harves...
PDF
Fuzzy based control of Transformer less Coupled inductor based DC-DC converter
PDF
Fr3610401047
ANALYSIS OF SOLID STATE TRANSFORMER WITH PERMANENT MAGNET SYNCHRONOUS GENERATOR
Solid state transformer ppt
Comparison of an Isolated bidirectional Dc-Dc converter with and without a Fl...
Design of Half Bridge LLC Resonant Converter for Low Voltage Dc Applications
Solar Based Stand Alone High Performance Interleaved Boost Converter with Zvs...
A Comparative Study of Various AC-DC Converters for Low Voltage Energy Harves...
Fuzzy based control of Transformer less Coupled inductor based DC-DC converter
Fr3610401047

What's hot (18)

PPTX
SOLID STATE TRANSFORMER - USING FLYBACK CONVERTER
PDF
Design of an Integrated Power Factor Converter with PI Controller for Low Pow...
PDF
STRAY LOSS ESTIMATION IN INDUCTION MOTOR
PDF
Comparative Evaluation of Generalized Multicell Impedance Source Inverter for...
PDF
12 16134 paper 064 ijeecs(edit)
PDF
Reactive Power Compensation in 132kv & 33kv Grid of Narsinghpur Area
PDF
MICROCONTROLLER BASED SOLAR POWER INVERTER
PDF
DESIGN OF A MULTIFUNCTIONAL FLYBACK DC-DC CONVERTER WITH CURRENT CONTROL
PDF
IJERD (www.ijerd.com) International Journal of Engineering Research and Devel...
PDF
Performance and Analysis of Hybrid Multilevel Inverter fed Induction Motor Drive
PDF
Ijetr012011
PDF
NON-ISOLATED SOFT SWITCHING DC-DC CONVERTER AND LOAD AT FULL RANGE OF ZVS
PDF
Base paper
PDF
Proposed PV Transformer-Less Inverter Topology Technique for Leakage Current ...
PDF
IMPEDANCE SOURCE INVERTER TOPOLOGIES FOR PHOTOVOLTAIC APPLICATIONS – A REVIEW
PDF
SIMULATION AND ANALYSIS OF PERMANENT MAGNET SYNCHRONOUS GENERATOR FOR RENEWAB...
PDF
Enhancement of power quality in a
PDF
Ki3418621868
SOLID STATE TRANSFORMER - USING FLYBACK CONVERTER
Design of an Integrated Power Factor Converter with PI Controller for Low Pow...
STRAY LOSS ESTIMATION IN INDUCTION MOTOR
Comparative Evaluation of Generalized Multicell Impedance Source Inverter for...
12 16134 paper 064 ijeecs(edit)
Reactive Power Compensation in 132kv & 33kv Grid of Narsinghpur Area
MICROCONTROLLER BASED SOLAR POWER INVERTER
DESIGN OF A MULTIFUNCTIONAL FLYBACK DC-DC CONVERTER WITH CURRENT CONTROL
IJERD (www.ijerd.com) International Journal of Engineering Research and Devel...
Performance and Analysis of Hybrid Multilevel Inverter fed Induction Motor Drive
Ijetr012011
NON-ISOLATED SOFT SWITCHING DC-DC CONVERTER AND LOAD AT FULL RANGE OF ZVS
Base paper
Proposed PV Transformer-Less Inverter Topology Technique for Leakage Current ...
IMPEDANCE SOURCE INVERTER TOPOLOGIES FOR PHOTOVOLTAIC APPLICATIONS – A REVIEW
SIMULATION AND ANALYSIS OF PERMANENT MAGNET SYNCHRONOUS GENERATOR FOR RENEWAB...
Enhancement of power quality in a
Ki3418621868
Ad

Viewers also liked (17)

PDF
Bidirectional full bridge dc-dc converter with flyback snubber for photovolta...
PDF
Quasi-resonant Flyback Converter Simulations with Saber - APEC 2016
PPTX
DC-DC-Converter Evaluation Report
PPTX
Bi-directional Flyback DC-DC Converter
PPT
A dual active bridge dc-dc converter for application in a smart user network
PDF
EE452_Flyback Convert
PPTX
A Novel High Step-Up Dc-Dc Converter for a Microgrid System
PPTX
Design of DC-DC Converter for SMPS with Multiple isolated outputs.
PPTX
FLYBACK CONVERTER PPT
PPTX
Bidirectional DC-DC isolated converter
PPTX
high voltage step-up dc-dc converter with coupled inductor
PPTX
Dc to Dc Converter (chopper)
PPTX
DC DC Converter
PDF
dc to dc-converter
PPT
Boost converter
PPTX
Microgrid Presentation
PDF
An isolated three port bidirectional dc-dc converter for photovoltaic systems...
Bidirectional full bridge dc-dc converter with flyback snubber for photovolta...
Quasi-resonant Flyback Converter Simulations with Saber - APEC 2016
DC-DC-Converter Evaluation Report
Bi-directional Flyback DC-DC Converter
A dual active bridge dc-dc converter for application in a smart user network
EE452_Flyback Convert
A Novel High Step-Up Dc-Dc Converter for a Microgrid System
Design of DC-DC Converter for SMPS with Multiple isolated outputs.
FLYBACK CONVERTER PPT
Bidirectional DC-DC isolated converter
high voltage step-up dc-dc converter with coupled inductor
Dc to Dc Converter (chopper)
DC DC Converter
dc to dc-converter
Boost converter
Microgrid Presentation
An isolated three port bidirectional dc-dc converter for photovoltaic systems...
Ad

Similar to Modified dc dc converter for high input voltage applications (20)

PDF
IRJET- Design and Implementation of Isolated Multi-Output Flyback Converter
PDF
Iaetsd an interleaved boost converter integrating with
PPTX
Coupled inductor boost integrated flyback converter with high-voltage gain-1
PDF
15 47-58
PDF
Speed Control Of Separately Excited Dc Motor Using A High Efficiency Flyback ...
PDF
Revathi 13
PDF
IRJET- A Dual Stage Flyback Converter using VC Method
PDF
Iaetsd analysis of zvs, zcs interleaved boost - converterwith ac drive
PDF
An Asymmetrical Dc-Dc Converter with a High Voltage Gain
PDF
Low Current Ripple, High Efficiency Boost Converter with Voltage Multiplier
PDF
Electrical Discharge Machining Flyback Converter using UC3842 Current Mode PW...
PDF
An Efficient High Gain DC-DC Converter for Automotive Applications
PDF
A Single Switch High Gain Coupled Inductor Boost Converter
PDF
Improved High Gain Dc-Dc Converter with Reduced Noise
PDF
Resonant AC-DC Converter with Interleaved Boost PFC
PDF
[IJET- V2I2P17] Authors: Gaurav B. Patil., Paresh J. Shah
PDF
A Integrated Technique of SIDO PFC Fly back Converter in power system
PDF
Simulation and Analysis of Multiphase Boost Converter with Soft-Switching for...
DOCX
ANALYSIS OF FLYBACK CONVERTER
PDF
Ap4201274279
IRJET- Design and Implementation of Isolated Multi-Output Flyback Converter
Iaetsd an interleaved boost converter integrating with
Coupled inductor boost integrated flyback converter with high-voltage gain-1
15 47-58
Speed Control Of Separately Excited Dc Motor Using A High Efficiency Flyback ...
Revathi 13
IRJET- A Dual Stage Flyback Converter using VC Method
Iaetsd analysis of zvs, zcs interleaved boost - converterwith ac drive
An Asymmetrical Dc-Dc Converter with a High Voltage Gain
Low Current Ripple, High Efficiency Boost Converter with Voltage Multiplier
Electrical Discharge Machining Flyback Converter using UC3842 Current Mode PW...
An Efficient High Gain DC-DC Converter for Automotive Applications
A Single Switch High Gain Coupled Inductor Boost Converter
Improved High Gain Dc-Dc Converter with Reduced Noise
Resonant AC-DC Converter with Interleaved Boost PFC
[IJET- V2I2P17] Authors: Gaurav B. Patil., Paresh J. Shah
A Integrated Technique of SIDO PFC Fly back Converter in power system
Simulation and Analysis of Multiphase Boost Converter with Soft-Switching for...
ANALYSIS OF FLYBACK CONVERTER
Ap4201274279

More from eSAT Journals (20)

PDF
Mechanical properties of hybrid fiber reinforced concrete for pavements
PDF
Material management in construction – a case study
PDF
Managing drought short term strategies in semi arid regions a case study
PDF
Life cycle cost analysis of overlay for an urban road in bangalore
PDF
Laboratory studies of dense bituminous mixes ii with reclaimed asphalt materials
PDF
Laboratory investigation of expansive soil stabilized with natural inorganic ...
PDF
Influence of reinforcement on the behavior of hollow concrete block masonry p...
PDF
Influence of compaction energy on soil stabilized with chemical stabilizer
PDF
Geographical information system (gis) for water resources management
PDF
Forest type mapping of bidar forest division, karnataka using geoinformatics ...
PDF
Factors influencing compressive strength of geopolymer concrete
PDF
Experimental investigation on circular hollow steel columns in filled with li...
PDF
Experimental behavior of circular hsscfrc filled steel tubular columns under ...
PDF
Evaluation of punching shear in flat slabs
PDF
Evaluation of performance of intake tower dam for recent earthquake in india
PDF
Evaluation of operational efficiency of urban road network using travel time ...
PDF
Estimation of surface runoff in nallur amanikere watershed using scs cn method
PDF
Estimation of morphometric parameters and runoff using rs & gis techniques
PDF
Effect of variation of plastic hinge length on the results of non linear anal...
PDF
Effect of use of recycled materials on indirect tensile strength of asphalt c...
Mechanical properties of hybrid fiber reinforced concrete for pavements
Material management in construction – a case study
Managing drought short term strategies in semi arid regions a case study
Life cycle cost analysis of overlay for an urban road in bangalore
Laboratory studies of dense bituminous mixes ii with reclaimed asphalt materials
Laboratory investigation of expansive soil stabilized with natural inorganic ...
Influence of reinforcement on the behavior of hollow concrete block masonry p...
Influence of compaction energy on soil stabilized with chemical stabilizer
Geographical information system (gis) for water resources management
Forest type mapping of bidar forest division, karnataka using geoinformatics ...
Factors influencing compressive strength of geopolymer concrete
Experimental investigation on circular hollow steel columns in filled with li...
Experimental behavior of circular hsscfrc filled steel tubular columns under ...
Evaluation of punching shear in flat slabs
Evaluation of performance of intake tower dam for recent earthquake in india
Evaluation of operational efficiency of urban road network using travel time ...
Estimation of surface runoff in nallur amanikere watershed using scs cn method
Estimation of morphometric parameters and runoff using rs & gis techniques
Effect of variation of plastic hinge length on the results of non linear anal...
Effect of use of recycled materials on indirect tensile strength of asphalt c...

Recently uploaded (20)

PPTX
"Array and Linked List in Data Structures with Types, Operations, Implementat...
PPTX
Information Storage and Retrieval Techniques Unit III
PDF
Exploratory_Data_Analysis_Fundamentals.pdf
PPTX
CN_Unite_1 AI&DS ENGGERING SPPU PUNE UNIVERSITY
PPTX
Sorting and Hashing in Data Structures with Algorithms, Techniques, Implement...
PPTX
Graph Data Structures with Types, Traversals, Connectivity, and Real-Life App...
PDF
UEFA_Embodied_Carbon_Emissions_Football_Infrastructure.pdf
PPTX
tack Data Structure with Array and Linked List Implementation, Push and Pop O...
PPTX
Chapter 2 -Technology and Enginerring Materials + Composites.pptx
PDF
Prof. Dr. KAYIHURA A. SILAS MUNYANEZA, PhD..pdf
PPT
Chapter 1 - Introduction to Manufacturing Technology_2.ppt
PDF
Unit I -OPERATING SYSTEMS_SRM_KATTANKULATHUR.pptx.pdf
PPTX
Measurement Uncertainty and Measurement System analysis
DOC
T Pandian CV Madurai pandi kokkaf illaya
PDF
Cryptography and Network Security-Module-I.pdf
PDF
Introduction to Power System StabilityPS
PPTX
mechattonicsand iotwith sensor and actuator
PDF
August -2025_Top10 Read_Articles_ijait.pdf
PDF
UEFA_Carbon_Footprint_Calculator_Methology_2.0.pdf
PPTX
Petroleum Refining & Petrochemicals.pptx
"Array and Linked List in Data Structures with Types, Operations, Implementat...
Information Storage and Retrieval Techniques Unit III
Exploratory_Data_Analysis_Fundamentals.pdf
CN_Unite_1 AI&DS ENGGERING SPPU PUNE UNIVERSITY
Sorting and Hashing in Data Structures with Algorithms, Techniques, Implement...
Graph Data Structures with Types, Traversals, Connectivity, and Real-Life App...
UEFA_Embodied_Carbon_Emissions_Football_Infrastructure.pdf
tack Data Structure with Array and Linked List Implementation, Push and Pop O...
Chapter 2 -Technology and Enginerring Materials + Composites.pptx
Prof. Dr. KAYIHURA A. SILAS MUNYANEZA, PhD..pdf
Chapter 1 - Introduction to Manufacturing Technology_2.ppt
Unit I -OPERATING SYSTEMS_SRM_KATTANKULATHUR.pptx.pdf
Measurement Uncertainty and Measurement System analysis
T Pandian CV Madurai pandi kokkaf illaya
Cryptography and Network Security-Module-I.pdf
Introduction to Power System StabilityPS
mechattonicsand iotwith sensor and actuator
August -2025_Top10 Read_Articles_ijait.pdf
UEFA_Carbon_Footprint_Calculator_Methology_2.0.pdf
Petroleum Refining & Petrochemicals.pptx

Modified dc dc converter for high input voltage applications

  • 1. IJRET: International Journal of Research in Engineering and Technology ISSN: 2319-1163 __________________________________________________________________________________________ Volume: 01 Issue: 03 | Nov-2012, Available @ http://www.ijret.org 474 MODIFIED DC-DC CONVERTER FOR HIGH INPUT VOLTAGE APPLICATIONS Battula.VeeraVasanthaRao1 , Sravanthi.Kantamaneni2 1 Assistant Professor, E.E.E Dept., 2 Assistant Professor, E.C.E Dept veeravasantharao@gmail.com, 2 sravanthi.kantamneni@yahoo.com Abstract: This paper proposes a model for high input voltage applications using two fly-back converters. In this the components are arranged by using integrated magnetic techniques. To reduce the voltage stresses the input components are connected in series and to obtain the required output the output components are connected in parallel. The three cores of the fly-back transformers are air gaped to reduce the current spikes which are caused due to coupling and the secondary side of the transformers are inversely coupled for ripple cancellation. This is done by using a prototype which helps us to obtain output as we desired for certain input with certain transformation ratio. The components used are IGBT’s, capacitors and fly-back transformers. Keywords: Integrated magnetic techniques fly back converter, coupling, ripple reduction, interleaved operation. ----------------------------------------------------------------------*****--------------------------------------------------------------------- I. INTRODUCTION: Integrated magnetic techniques combine transformers and inductors into a single core in order to reduce the size and cost of magnetic components in dc/dc converters. Principles of modeling and designing integrated magnetic have been widely published. Historically, integrated dc/dc converters were first developed for Forward converters. However, recently integrated magnetic full wave circuits have been extensively studied. These full wave circuits have reported significant benefits, including high efficiency, high power density and low switch stress. Applications of these circuits are being proposed in 30 W - 100 W ranges, and have great potential for telecommunication power supplies. A “typical”2 integrated magnetic full wave dc/dc converter, which uses a three-leg magnetic core. This class of full wave integrated magnetic circuit‟s exhibits a common character that there is no winding on the inductor leg. Instead, the secondary windings play the role of the equivalent Inductor winding, and hence, the secondary windings must satisfy both power transfer and current ripple restrictions for different operating stages. The elimination of the inductor winding comes from the magnetic integration methods, and, in applications, this is believed to reduce the copper loss and simplify the transformer structure. However, optimum transformer design must keep the balance between copper loss, ferrite loss and total size. In integrated magnetic transformers, the number of secondary winding turns influences the number of primary winding turns, the magnetic core size and the output current characteristics. This places a burden on the secondary winding turn decision and complicates the transformer design. As a result, the magnetic core often needs to be specially designed and manufactured in order to satisfy both output current ripple requirements and flux density constraints. Using flyback converter this integrated magnetic techniques are employed.It is equivalent to that of a buck-boost converter, with the inductor split to form a transformer . Therefore the operating principle of both converters is very close: When the switch is on, the primary of the transformer is directly connected to the input voltage source. This results in an increase of magnetic flux in the transformer. The voltage across the secondary winding is negative, so the diode is reverse-biased (i.e., blocked). The output capacitor supplies energy to the output load. When the switch is off, the energy stored in the transformer is transferred to the output of the converter. The operation of storing energy in the transformer before transferring to the output of the converter allows the topology to easily generate multiple outputs with little additional circuitry, although the output voltages have to be able to match each other through the turns ratio. This paper uses two fly-back converters which act as fly-back transformers which are designed under a single magnetic core. Earlier they designed a converter based on this concept. The main features of that converter are  Earlier designed a single magnetic core three limbed transformer with center limb air gapped. So that the current spikes can be reduced.  The primary and secondary side of the transformer is connected in parallelthe operation is similar to that of a fly-back converter with two switches on the primary side and two capacitors on the secondary side. The secondary side is directly coupled.
  • 2. IJRET: International Journal of Research in Engineering and Technology ISSN: 2319-1163 __________________________________________________________________________________________ Volume: 01 Issue: 03 | Nov-2012, Available @ http://www.ijret.org 475 Whereas coming to the modified converter the changes made and the specified reasons for the changes are as discussed below.  Connecting the primary side in series reduces the voltage stresses of the primary components. The primary switches are rated at half of the corresponding voltage values in a single Fly-back or a traditional full wave buck-boost power converter.  The on-resistance and cost of the primary switches are, thus, significantly reduced. Alternatively, this implies that for the same rated switches, the proposed converter can handle twice the input voltage compared with the converter.  Interleaved operation with paralleled connection on the secondary side keeps the benefits of ripple reduction as a traditional full wave buck-boost power converter does.  To satisfy a certain current ripple requirement, magnetizing inductance can be reduced by means of suitable inductor coupling design.  Due to the mutual influence of the two coupled inductors that is combined with the transformers, further current ripple reduction can be achieved when compared with interleaved Fly-back converters without coupling.  Also, the amount of the magnetic components is reduced by integrating the two transformers into one magnetic core, although the efficiency of the new approach may not be improved when compared with conventional discrete interleaved Fly-backs.  Current spike caused by the voltage mismatch between the windings can be suppressed by gapping all the center and outer legs. Compared with tight coupling, such as the condition in a traditional full wave buck-boostpower converter, gapping all the legs weakens the coupling between the two Fly-backs‟ windings, and thus,reduces the effect of the voltage mismatch. Between the two Fly- backs‟ windings, and thus, reduces the effect of the voltage mismatch. The modified converter is as shown below which consists of IGBT‟s which act as switches on the primary side, thecapacitors help in the timing operation of the converter depending on the intervals. And the secondary consists of diodes D1 and D2 which are reversely coupled for the sake of ripple reduction. And the operation of the converter is as discussed below. Figure representing the circuit model of the modified dc-dc converter Operation principle The main primaries switch and are the auxiliary switches, which are connected with the reset windings to obtain active clamp. Vc1, Vc2, Vc3 are the voltages across c1, c2, c3. Capacitors Cr1 and Cr2 are the equivalent resonant capacitors of q1, q2. c1, q1, t1, q3 and c3 are the primary side components of one active-clamp forward, while the other forward consists of c2, q2,t2, q4 and c3. The two forward circuits share the clamping capacitor c3 so that the charge balances of c1 and c2 are kept. Since the control signals of the two channels have the same duty cycle, unbalanced voltage on c1, c2 and can generate different magnetizing current to charge the capacitors. Therefore, the two input voltages are adjusted to a balanced value at steady state. Also, the two channels share the freewheeling switch q7 and output inductor L1on the secondary side. Therefore, there is no current sharing problem. The size of the output inductor is reduced due to interleaved operation. One potential concern is the effect of the leakage inductor between the primary winding and the active clamp winding. The energy stored in the leakage inductor can impose excessive voltage spikes on the switches. This leads to higher voltage stress on the switches and should be taken into
  • 3. IJRET: International Journal of Research in Engineering and Technology ISSN: 2319-1163 __________________________________________________________________________________________ Volume: 01 Issue: 03 | Nov-2012, Available @ http://www.ijret.org 476 account for design. Thus, transformers with tight coupling are required. Also, effective snubber is helpful to reduce the voltage stress. The following description explains the detailed operation principle of the proposed topology. In general, circuit operation can be qualitatively described over several modes/intervals. The upper forward circuit transfers energy to secondary side during time interval t0 – t1.The under forward circuit transfer energy during interval t7 – t8. Interval t4 – t5 and interval t11 – t12 are utilized for the freewheeling process of theoutput current. All the remaining intervalsare transition intervals and are substantially smaller in length than energy transfer or freewheeling time intervals. Interval t0 – t14is defined as the switching period T1. The lengths of t0 – t1 and t7 – t8 are defined as DT, which represents the duty ratio, and thus, the duty ratio D will always be less than one-half. The lengths of t1 – t4 and t8 – t11 are set to a suitable value td, which is longer than the required transition time t1 – t3 and t8 – t10. The length of t0 – t1 and t7 – t8 are defined as DT, which represents the duty ratio. 2. FLUX DISTRIBUTIONS ANALYSIS: For the convenience of magnetic design, it is necessary to providethe formulas for flux distributions. To prevent the magneticcore from saturating, the peak values of the flux densities in allthree legs should be keptbelow a specified maximum valueTherefore, this section will discuss the detailed calculation forboth the ac fluxes and dc fluxes in all three legs. As a result, thepeak values of the fluxes are the sum of the dc fluxes and half of the ac fluxes showsthe magnetic reluctance circuit of the proposedtopology, assuming the conditions of the two outer legs are symmetrical. Also, Fig shows the flux path of in the core of transformer.Because of the air gap, the center leg is no longer alow magnetic reluctance path for the fluxes. The flux generated by each winding in the outer legs can go through all threelegs. The flux interaction between the windings affects the currentripple and peak values of the flux densities Furthermore, following figure shows the detailed equivalent magneticreluctance circuit during each interval. The effect of the correspondingwinding is removed when the current in the windingis zero. Figures a,b,c,d respectively shows the flux path in the core Of which fig a represents flux path during the interval t0-t1 similarlyfig b during t1-t2, fig c during t2-t3 and fig d during t3-t4. The equations corresponding to their flux paths and intervals are T0-T1: Фc= (Vin/2Np)-(V0/Ns) T1-T2: Фc=- (2V0/Ns) T2-T3: Фc= (Vin/2Np)-(V0/Ns) T3-T4: Фc=- (2V0/Ns) Thus by the analysis all the fluxes in the system i.e. both the ac and dc fluxes obtained are
  • 4. IJRET: International Journal of Research in Engineering and Technology ISSN: 2319-1163 __________________________________________________________________________________________ Volume: 01 Issue: 03 | Nov-2012, Available @ http://www.ijret.org 477 Total ac flux in the two outer limbs is obtained as ∆ф1= ∆ф2=V0(1-D)/Nsfs The total ac flux in the center limb obtained as ∆фc=V0 (1-2D)/Nsfs DC Flux: Фc=ф1+ф2 = (Np1Ip1+Ns1Is1+Np2Ip2+Ns2Is2)(1/(R0+2Rc) To avoid the saturation of the magnetic core, the peak value ofthe flux densities of all three legs should be computed. The peak value can be obtained by the sum of DC fluxes and half of the total AC fluxes. By using the calculation of the current ripple and the peakflux densities suitable magnetic core size and the turnnumbers of the windings can be chosen to satisfy the currentripple restrictions and the magnetic constraints. 3. SIMULATION AND RESULTS: The Simulink model of the converter is as shown below. In this dual converter two interleaved forward circuits are connected in series on the primary side and in parallel on the secondary side the two transformers share one low voltage capacitor for clamping through auxiliary windings and switches. Through the resonance between the magnetizing inductors and equivalent capacitors of the switches during the transition time, switching loss of the primary switches can be reduced. Output current and voltage wave forms when firing pulses from same firing circuit. When firing pulses are giving from a single pulse generating circuit wave forms are shown in graph here input voltage is 400V, output is 20V and current. Fig-1: output current and voltage wave forms when firing pulses from same firing circuit. When firing pulses for individual switches is given from different firing circuits the only difference is output voltage, output current values are changed and in this input voltage is same is same that is 400V.but output voltage is25V and output current is 0.7A Fig-2: output voltage and current wave forms when firing pulses are from different firing circuits. Specifically, the following differences are remarked when compared with a traditional converter in. 1) The new approach connects the input of the two Fly backs in series, while the traditional method connects the input in parallel. 2) The proposed converter has three gaps in all legs. The traditional converter only has one gap in the center leg. 3) The secondary windings are inversely coupled in the new converter, and directly coupled in the traditional converter. From the first difference, it can be concluded that the proposed method has half of the voltage stress when compared with the traditional method. According to the second and third differences, the secondary windings of the traditional converter are directly coupled with tight coupling. However, for practicalcircuits, especially for this high voltage application, switches cannot operate exactly simultaneously. There is a voltage mismatch between the two secondary windings. The voltage difference is applied to the leakage inductance between the twowindings. Because the two outer legs have low reluctances, and the center leg has a high reluctance, the two secondary windings have good coupling and small leakage inductance. Minor mismatch can lead to high current spikes and resonance. On the other hand, the secondary windings of the new converterare inversely coupled with not so tight couplingsince all three legs are gapped. By gapping all the three legs, a big leakage inductance between the windings of the two Transformers is obtained, since the flux generated by each winding in the outer legs can go through all three legs (is approximately equal to 1/3 when all the legs have gaps with approximately same distances.) The large inductance value can avoid high current spike when a voltage mismatch is applied. Also, current ripple reduction can still be achieved with suitable coupling design. We also remark that the weakened coupling between the two transformers allows the duty ratio to be greater than 50% in the propose circuit
  • 5. IJRET: International Journal of Research in Engineering and Technology ISSN: 2319-1163 __________________________________________________________________________________________ Volume: 01 Issue: 03 | Nov-2012, Available @ http://www.ijret.org 478 CONCLUSIONS The dual interleaved forward converter may be beneficial for high current/ high power density designs. This converter topology would be ideal for intermediate bus converters and merchant power applications because the reduced input and output capacitor ripple current reduces electrical stress on the input and output capacitors. The inductor ripple current cancellation of interleaving converters allows the design more output capacitance, which in turn should reduce the design's output capacitance requirements. Interleaving techniques are adopted to reduce input/output current or voltage ripples for converters with critical conduction mode. This is useful for not only buck operation and also for boosting purpose. In this study implements two types of phase-shift control schemes for critical interleaved boost PFC converters. Sub-harmonic oscillation phenomena occur at high line voltage when one of them is adopted. So this paper presents a quantitative analysis on the phenomena and proposes a novel phase-shift control scheme. REFERENCES: [1] G. C. Hua and F. C. Lee, “Novel zero voltage transition PWM converters,‟ in Proc. IEEE Power Electronspec.conf., 1992, pp.55-61. [2] J.G. Cho et al., “zero-voltage and zero-current-switching full bridge PWM converter for high-power applications,‟ IEEE Trans. Power Electron., vol.11, pp.622-628, July 1996. [3] T. Morimoto, shirakawa, O. Koudriavtsev, and M. Nakaoka, ‟ zero-voltage zero current hybrid soft-switching phase-shifted PWM dc-dc power converter for high power applications, „in Proc.IEEE APEC‟00,New Orleans,LA,Feb.2000,pp.104-110. [4] R. Redl, N.O. Sokal, and L. Balogh, ” A novel soft- switching full-bridge dc/dc converter: analysis, design considerations, and experimental results at 1.5 KW, 100KHz, ” IEEE Trans.Power Electron., vol.6,pp.408-418, july 1996. [5] H.J.Kim and H.J.Kim, „Active clamp forward converter with MOSFET synchronous rectification,” in Proc. Power Electronics Specialists conf., 1994, vol.2.pp.895-901. [6] Y.K.Lo, T.S.Kao, and J.Y.Lin, “Analysis and design of an interleaved active-clamping forwardconverter, IEEEtRANS.lnd.Electron” vol.54, no.4, pp.2323-2332, Aug 2007.