This document presents a study on the performance-based seismic design of a reinforced concrete building. It describes performing pushover analysis on a G+5 building located in seismic zones 3, 4 and 5 of India. The building is designed according to Indian codes IS 1893 and IS 456 for maximum considered earthquake and design based earthquake conditions. Nonlinear static (pushover) analysis is conducted using ETABS to obtain the capacity curve, demand spectrum, and performance point for each zone and earthquake level. Results for storey displacement, drift, and plastic hinge formation are presented and compared. It is concluded that displacement and drift increase with zone but load capacity also increases. The performance-based design approach allows evaluating how the building will actually perform se