© s::can GmbH (2020)
www.s-can.at
pH::lyser
∙
∙ s::can plug & measure
∙
∙ measuring principle: unique, non-porous / non-leaking
combined reference electrode for technically unrivalled and
consistent pH performance
∙
∙ multiparameter sensor
∙
∙ ideal for surface water, ground water, drinking water and
waste water
∙
∙ long term stable and maintenance free in operation
∙
∙ factory precalibrated
∙
∙ mounting and measurement directly in the media (InSitu)
or in a flow cell
∙
∙ operation via s::can terminals & s::can software
∙
∙ optional: automatic cleaning with compressed air
∙
∙ plug connection or fixed cable
35
38
33
27,6
255
33
27,6
54
257
Messgeräte Sonstige Daten
recommended accessories
part number article name
C-1-010-sensor 1 m connection cable for s::can physical and ISE probes
D-315-xxx con::cube
D-320-xxx con::lyte
F-12-sensor carrier s::can physical probes
F-45-four flow cell for four s::can physical probes
F-46-four-iscan i::scan flow cell for up to 3 additional s::can probes
F-45-sensor flow cell for s::can sensor
S-11-xx-moni moni::tool Software
pH::lyser eco monitors pH & temperature
pH::lyser pro: high temperature range
© s::can GmbH (2020)
www.s-can.at
technical specification
measuring principle potentiometric
measuring principle detail combined, non-porous reference
electrode
resolution 0.01 pH
accuracy (standard solution) 0.1 pH
automatic compensation instrument temperature
response time (T90) 30 ... 0 sec.
integrated temperature sensor 0 ... 90 °C
integration via con::cube
con::lyte
con::nect
power supply 9 … 18 VDC
power consumption (typical) 0.8 W
power consumption (max.) 1 W
interface to s::can terminals sys plug (IP67), RS485
cable length 7.5 m fixed cable (-075) or
plug connection (-000)
cable type PU jacket
housing material stainless steel 1.4404/1.4401,
POM-C
or
stainless steel 1.4404/1.4401, PVC
(E-514-4-075)
weight (min.) 400 g
dimensions (Ø x l) 33 x 257 mm
operating pressure 0 ... 10 bar
installation / mounting submersed or in a flow cell
process connection quick connect
flow velocity 3 m/s (max.)
0.01 m/s (min.)
automatic cleaning media: compressed air
permissible pressure: 3 ... 6 bar
storage temperature (electrode) -5 ... 30 °C
storage temperature (sensor) -10 ... 60 °C
conformity - EMC EN 61326-1
conformity - safety EN 61010-1
operating temperature (eco) 0 ... 70 °C
operating temperature (pro) 0 ... 90 °C
protection class (-000) IP67
protection class (-075) IP68
measuring range
parameter
pH
[pH]
temperature
[°C]
part number
pH::lyser eco
(pH, temp)
min. 2 0 E-514-2-000 / -075
max. 12 70
pH::lyser pro
(pH, temp)
min. 0 0 E-514-3-000 / -075
max. 13 90

More Related Content

PDF
Spectrolyser titanium dw_en_multi parameter_scan
PDF
Oxilyser ww en_oxygen do sensor_scan
PDF
Redolyser ww en_orp temp sensor_scan
PDF
Spectrolyser v3 dw_en_multi parameter_scan
PDF
Ozolyser v3 ww_en_ozone tss sensor_scan
PDF
Carbon analysis cod toc bod sensor-wtw
PDF
Spectrolyser titanium ww_en_multi parameter_scan
PDF
Multilyser v3 ww_en_wastewater multi parameter sensor_scan
Spectrolyser titanium dw_en_multi parameter_scan
Oxilyser ww en_oxygen do sensor_scan
Redolyser ww en_orp temp sensor_scan
Spectrolyser v3 dw_en_multi parameter_scan
Ozolyser v3 ww_en_ozone tss sensor_scan
Carbon analysis cod toc bod sensor-wtw
Spectrolyser titanium ww_en_multi parameter_scan
Multilyser v3 ww_en_wastewater multi parameter sensor_scan

What's hot (20)

PDF
Redolyser dw en_orp temp sensor_scan
PDF
Iscan dw en_turbidity sensor_scan
PDF
Spectrolyser industrial ww_en_multi parameter_scan
PDF
Nitrolyser v3 ww_en_no3 tss parameters sensor_scan
PDF
Ozolyser v3 dw_en_ozone turbidity sensor_scan
PDF
Spectrolyser v3 ww_en_multi parameter_scan
PDF
Varion plus 700 iq nh4 no3 sensor-wtw
PDF
Condulyser ww en_conductivity salinity digital sensor_scan
PDF
Solilyser ww en_tss mlss sensor_scan
PDF
Oxygen do measurement wtw
PDF
Spectrolyser ww en_multi parameter_scan
PDF
Ammo lyt 700 iq ammonium nh4 sensor-wtw
PDF
Spectrolyser dw en_multi parameter_scan
PDF
Alyza iq nh4 analyzer wtw
PDF
Hyperlyser dw en - S::CAN
PDF
Senso lyt 700 iq ph orp sensor-wtw
PDF
Iscan ww en_cod tss color sensor_scan
PDF
WTW catalog process instrumentation in water industry
PDF
Uvlyser v3 ww_en_tss uv254 in water_scan
PDF
Vi solid 700 iq tss sensor-wtw
Redolyser dw en_orp temp sensor_scan
Iscan dw en_turbidity sensor_scan
Spectrolyser industrial ww_en_multi parameter_scan
Nitrolyser v3 ww_en_no3 tss parameters sensor_scan
Ozolyser v3 dw_en_ozone turbidity sensor_scan
Spectrolyser v3 ww_en_multi parameter_scan
Varion plus 700 iq nh4 no3 sensor-wtw
Condulyser ww en_conductivity salinity digital sensor_scan
Solilyser ww en_tss mlss sensor_scan
Oxygen do measurement wtw
Spectrolyser ww en_multi parameter_scan
Ammo lyt 700 iq ammonium nh4 sensor-wtw
Spectrolyser dw en_multi parameter_scan
Alyza iq nh4 analyzer wtw
Hyperlyser dw en - S::CAN
Senso lyt 700 iq ph orp sensor-wtw
Iscan ww en_cod tss color sensor_scan
WTW catalog process instrumentation in water industry
Uvlyser v3 ww_en_tss uv254 in water_scan
Vi solid 700 iq tss sensor-wtw
Ad

Similar to Phlyser dw en_ph temp sensor_scan (20)

PDF
Phlyser ww en_ph temp sensor_scan
PDF
Oxilyser dw en_oxygen do sensor_scan
PDF
Fluorlyser dw en_flo sensor_scan
PDF
Lutron PH-207 PH-mV-TEMP. Meter
PDF
Eutech Ph 510
PDF
ATI_Q46PR.pdf
PDF
Testo 206 datasheet 2012
PDF
ProCon P14E PH Sensor .pdf
PDF
pHmetro OAKTAN 1100.pdf
PDF
Tài liệu hãng AQUALABO Catalog 2021.pdf
PDF
pH / Ion meter from Metrohm
PDF
Ion Meter from Metrohm
PDF
Tester and rapid kit for analysis catalog
PDF
Tester and rapid kit for analysis catalog
PDF
Tester and rapid kit for analysis catalog
PPTX
pH Analzyer
PDF
Tester and rapid kit for analysis catalog
PDF
Liquid Analytical Instrumentation for Process Control
PPT
Analytical Measurements: Troubleshooting, Maintenance and the Future
PDF
Lutron PWH-303 Water Hardness Meter
Phlyser ww en_ph temp sensor_scan
Oxilyser dw en_oxygen do sensor_scan
Fluorlyser dw en_flo sensor_scan
Lutron PH-207 PH-mV-TEMP. Meter
Eutech Ph 510
ATI_Q46PR.pdf
Testo 206 datasheet 2012
ProCon P14E PH Sensor .pdf
pHmetro OAKTAN 1100.pdf
Tài liệu hãng AQUALABO Catalog 2021.pdf
pH / Ion meter from Metrohm
Ion Meter from Metrohm
Tester and rapid kit for analysis catalog
Tester and rapid kit for analysis catalog
Tester and rapid kit for analysis catalog
pH Analzyer
Tester and rapid kit for analysis catalog
Liquid Analytical Instrumentation for Process Control
Analytical Measurements: Troubleshooting, Maintenance and the Future
Lutron PWH-303 Water Hardness Meter
Ad

More from ENVIMART (20)

PDF
Zinc Continuous Analysis from SEIBOLD-Wasser.pdf
PDF
Nickel Continuous Analysis from SEIBOLD-Wasser.pdf
PDF
Manganese Continuous Analysis from SEIBOLD-Wasser.pdf
PDF
Lead Continuous Analysis from SEIBOLD-Wasser.pdf
PDF
Iron Manganese Continuous Analysis from SEIBOLD-Wasser.pdf
PDF
Iron Continuous Analysis from SEIBOLD-Wasser.pdf
PDF
Chromium Continuous Analysis from SEIBOLD-Wasser.pdf
PDF
Copper Zinc Continuous Analysis from SEIBOLD-Wasser.pdf
PDF
Copper Nickel Continuous Analysis from SEIBOLD-Wasser.pdf
PDF
Copper Continuous Analysis from SEIBOLD-Wasser.pdf
PDF
Cobalt Continuous Analysis from SEIBOLD-Wasser.pdf
PDF
Cadmium Continuous Analysis from SEIBOLD-Wasser.pdf
PDF
Arsenic Continuous Analysis from SEIBOLD-Wasser.pdf
PDF
Aluminium Continuous Analysis from SEIBOLD-Wasser.pdf
PDF
ATIs-B12-2-Wire-Gas-Transmitter-Product-Literature.pdf
PDF
ATIs-B12-2-Wire-Gas-Transmitter-Support-Drawings.pdf
PDF
ATIs-B12-Wet-Gas-Detector-Product-Literature.pdf
PDF
ATIs-B12-Wet-Gas-Detector-Support-Drawings.pdf
PDF
ATIs-B14-Gas-Alarm-Module-Product-Literature.pdf
PDF
B12-2-Wire-Gas-Transmitter.pdf
Zinc Continuous Analysis from SEIBOLD-Wasser.pdf
Nickel Continuous Analysis from SEIBOLD-Wasser.pdf
Manganese Continuous Analysis from SEIBOLD-Wasser.pdf
Lead Continuous Analysis from SEIBOLD-Wasser.pdf
Iron Manganese Continuous Analysis from SEIBOLD-Wasser.pdf
Iron Continuous Analysis from SEIBOLD-Wasser.pdf
Chromium Continuous Analysis from SEIBOLD-Wasser.pdf
Copper Zinc Continuous Analysis from SEIBOLD-Wasser.pdf
Copper Nickel Continuous Analysis from SEIBOLD-Wasser.pdf
Copper Continuous Analysis from SEIBOLD-Wasser.pdf
Cobalt Continuous Analysis from SEIBOLD-Wasser.pdf
Cadmium Continuous Analysis from SEIBOLD-Wasser.pdf
Arsenic Continuous Analysis from SEIBOLD-Wasser.pdf
Aluminium Continuous Analysis from SEIBOLD-Wasser.pdf
ATIs-B12-2-Wire-Gas-Transmitter-Product-Literature.pdf
ATIs-B12-2-Wire-Gas-Transmitter-Support-Drawings.pdf
ATIs-B12-Wet-Gas-Detector-Product-Literature.pdf
ATIs-B12-Wet-Gas-Detector-Support-Drawings.pdf
ATIs-B14-Gas-Alarm-Module-Product-Literature.pdf
B12-2-Wire-Gas-Transmitter.pdf

Recently uploaded (20)

PPTX
Introduction to GLOBE by well renowned people
PPTX
SCADAhjknvbxfbgmmmmmmmmmmmmmmmmmmmmmmm.pptx
DOCX
Biogas Balloon for Pig Farm Plants Holds biogas from hog farm waste..docx
PDF
2025-08-23 Composting at Home 101 without voucher link and video.pdf
PPTX
IMO 2020 - FUELS AND LUBES UPDATE -cs.pptx
PPTX
IMPACTS OF CHEMICAL FERTILIZERS -CHEMPROJ (11).pptx
DOCX
Anaerobic Digester Tanks An ideal solution for a circular economy..docx
PPTX
Drought management class in a simplified manner
PDF
IWRM - City University Presentation 28 may 2018-v3.pdf
PPTX
Drought and it's classification in a simplified way
PDF
rainfed swc for nature and agroforestrys
DOCX
Aluminum Dome Roofs for Harvested Rainwater Tanks Provides a Durable, Sealed ...
PPTX
Lecture-05-Audio-lingual. Method & Appro
PDF
BD4E4- DISASTER MANAGEMENT BY A.R.SIVANESH.pdf
PPTX
Pollution, it's Types and Impacts on Global context.pptx
DOCX
Biogas Balloon for Bio CNG Plants An efficient solution for biogas storage..docx
PPTX
Science and Society 011111111111111111111
PDF
Ciba Foundation Symposium - Cell Differentiation -- de Reuck, A_ V_ S_ (edito...
PPTX
EVS HUMAN AND ENVIRONMENT- RELATIONSHIP
PPTX
Relation Between Forest Growth and Stand Density.pptx
Introduction to GLOBE by well renowned people
SCADAhjknvbxfbgmmmmmmmmmmmmmmmmmmmmmmm.pptx
Biogas Balloon for Pig Farm Plants Holds biogas from hog farm waste..docx
2025-08-23 Composting at Home 101 without voucher link and video.pdf
IMO 2020 - FUELS AND LUBES UPDATE -cs.pptx
IMPACTS OF CHEMICAL FERTILIZERS -CHEMPROJ (11).pptx
Anaerobic Digester Tanks An ideal solution for a circular economy..docx
Drought management class in a simplified manner
IWRM - City University Presentation 28 may 2018-v3.pdf
Drought and it's classification in a simplified way
rainfed swc for nature and agroforestrys
Aluminum Dome Roofs for Harvested Rainwater Tanks Provides a Durable, Sealed ...
Lecture-05-Audio-lingual. Method & Appro
BD4E4- DISASTER MANAGEMENT BY A.R.SIVANESH.pdf
Pollution, it's Types and Impacts on Global context.pptx
Biogas Balloon for Bio CNG Plants An efficient solution for biogas storage..docx
Science and Society 011111111111111111111
Ciba Foundation Symposium - Cell Differentiation -- de Reuck, A_ V_ S_ (edito...
EVS HUMAN AND ENVIRONMENT- RELATIONSHIP
Relation Between Forest Growth and Stand Density.pptx

Phlyser dw en_ph temp sensor_scan

  • 1. © s::can GmbH (2020) www.s-can.at pH::lyser ∙ ∙ s::can plug & measure ∙ ∙ measuring principle: unique, non-porous / non-leaking combined reference electrode for technically unrivalled and consistent pH performance ∙ ∙ multiparameter sensor ∙ ∙ ideal for surface water, ground water, drinking water and waste water ∙ ∙ long term stable and maintenance free in operation ∙ ∙ factory precalibrated ∙ ∙ mounting and measurement directly in the media (InSitu) or in a flow cell ∙ ∙ operation via s::can terminals & s::can software ∙ ∙ optional: automatic cleaning with compressed air ∙ ∙ plug connection or fixed cable 35 38 33 27,6 255 33 27,6 54 257 Messgeräte Sonstige Daten recommended accessories part number article name C-1-010-sensor 1 m connection cable for s::can physical and ISE probes D-315-xxx con::cube D-320-xxx con::lyte F-12-sensor carrier s::can physical probes F-45-four flow cell for four s::can physical probes F-46-four-iscan i::scan flow cell for up to 3 additional s::can probes F-45-sensor flow cell for s::can sensor S-11-xx-moni moni::tool Software pH::lyser eco monitors pH & temperature pH::lyser pro: high temperature range
  • 2. © s::can GmbH (2020) www.s-can.at technical specification measuring principle potentiometric measuring principle detail combined, non-porous reference electrode resolution 0.01 pH accuracy (standard solution) 0.1 pH automatic compensation instrument temperature response time (T90) 30 ... 0 sec. integrated temperature sensor 0 ... 90 °C integration via con::cube con::lyte con::nect power supply 9 … 18 VDC power consumption (typical) 0.8 W power consumption (max.) 1 W interface to s::can terminals sys plug (IP67), RS485 cable length 7.5 m fixed cable (-075) or plug connection (-000) cable type PU jacket housing material stainless steel 1.4404/1.4401, POM-C or stainless steel 1.4404/1.4401, PVC (E-514-4-075) weight (min.) 400 g dimensions (Ø x l) 33 x 257 mm operating pressure 0 ... 10 bar installation / mounting submersed or in a flow cell process connection quick connect flow velocity 3 m/s (max.) 0.01 m/s (min.) automatic cleaning media: compressed air permissible pressure: 3 ... 6 bar storage temperature (electrode) -5 ... 30 °C storage temperature (sensor) -10 ... 60 °C conformity - EMC EN 61326-1 conformity - safety EN 61010-1 operating temperature (eco) 0 ... 70 °C operating temperature (pro) 0 ... 90 °C protection class (-000) IP67 protection class (-075) IP68 measuring range parameter pH [pH] temperature [°C] part number pH::lyser eco (pH, temp) min. 2 0 E-514-2-000 / -075 max. 12 70 pH::lyser pro (pH, temp) min. 0 0 E-514-3-000 / -075 max. 13 90