POWER SYSTEM
CONTROL AND LINE
COMPENSATION
Submitted by
Roll no. 1120810(E-6)
and 1120508 (E-2)
CONTENTS:-
 Introduction
 Voltage control
 Power system control
 Control of reactive power and power factor
 Interconnected control and frequency ties
 Supervisory control
 Line compensation
 Series compensation
 Series and shunt compensation schemes for ac transmission system
Introduction
 Power system control and line compensation are essential for the effective
working of power system.
 Voltage ,frequency and power factor are the main items to be controlled.
 To get the desired voltage at the consumer end voltage control is necessary.
 Frequency control is done to form a synchronous link between two systems
having different frequencies.
 The control of reactive vars will automatically control the power factor of the
system.
 Nowadays Supervisory control for the power system is done from the main
control room.
Voltage Control
 The voltage control in power system is necessary mainly in the following
stages.
1. Generating end.
2. Transmission lines.
3. Receiving end.
Generating End Voltage Control Methods
Regulators using magnetic amplifiers
Electronic voltage regulators
Amplidyne control
Transistor voltage regulator
Thyristor automatic voltage regulator
SMALL DESCRIPTION ABOUT THE MODERN VOLTAGE
REGULATORS USED FOR CONTROLLING ALTERNATOR VOLTAGE.
 REGULATORS USING MAGNETIC AMPLIFIERS:> If the output voltage of the alternator
changes to a value other than the reference value then the ampere turns of the
control winding (combination of two dc windings arranged in opposition on the
core to have opposing magnetic field effects) changes which changes the field
current of exciter of alternator to maintain the constant output voltage.
 ELECTRONIC VOLTAGE REGULATORS:> It consists of bridge circuit with thyratron
valves which control the field of exciter.
 AMPLIDYNE CONTROL:> Exciter field current of the alternator is controlled using
amplidyne.
 TRANSISTOR VOLTAGE REGULATOR:> Transistorised circuitary is used for the field
current control.
 THYRISTOR AUTOMATIC VOLTAGE REGULATOR:> These are the completely static
voltage regulators having very fast response and they use high current thyristors.
EXCITATION SYSTEM USED FOR ALTERNATORS
DIRECT SELF EXCITATION
INDIRECT SELF EXCITATION
SEPARATE EXCITATION
 INDIRECT SELF EXCITATION:>In this the output of the thyristor regulator
control the field of exciter(can be ac with rotating rectifiers in brushless
alternator arrangement) and the supply voltage to the regulator is fed fron
generator itself.This system is used mainly for alternators of 100KVA to
several MVA.
 SEPARATE EXCITATION SYSTEM:> In this a pilot exciter act as a source to the
thyristor regulator which controls the amin excitor and supplies the field of
main generator . This system is used mainly for alternators of 100KVA to very
lagre size turbo alternators.
Power System Control And Line Compensation
Power System Control And Line Compensation
VOLTAGE REGULATION OF TRANSMISSION LINE
Methods used for regulation of T-line is as follows:
 TAP CHANGING TRANSFORMERS:> Voltage level at the substation or the load points can be
adjusted to desired level on load as well as off load.
 BOOSTER TRANSFORMER:> They are used to raise the potential at a point away from the main
transformer and are having a capacity of 10% to 20% of that of main transformers.
Selective load dispatching is necessary when stations in a systems are interconnected to avoid the
overloading of lines which can be done using devices given below.
 IN PHASE VOLTAGE BOOSTER TRANSFORMER:>It is used to inject voltage in phase with the line
voltage.
 QUADRATURE VOLTAGE BOOSTER TRANSFORMER:>It is used to inject voltage at right angle to
the line voltage.
 INDUCTION REGULATOR:>This is similar to that of wound rotor induction motor in which the
rotor is not free to rotate and rotor winding is connected in series with the stator winding .
Power System Control And Line Compensation
Power System Control And Line Compensation
VOLTAGE REGULATION OF TRANSMISSION LINE
On Load Tap changing transformers Booster transformer
Phase shifting transformer Induction Regulator
Servo control Static voltage control
 AUTOMATIC VOLTAGE CONTROL :> IT is affected by servo control having three
principal elements
1.Voltage regulating relay.
2.Intermediate relay.
3.Motor drive.
STATIC VOLTAGE CONTROL:>It is being used for high voltage transmission line upto
330 KV. The static network compensator employ ac saturating reactor for the
reactive power control and can be used in conjunction with the static compensator
which have following advantages:
o Instantaneous overvoltage prevention.
o Prevents loss of synchronism.
o Increases the capacity of transmission line.
o Increase in the stability limit.
o Possibility to increase transmission line length increases.
POWER SYSTEM CONTROL
The main problems of control are :
ACTIVE POWER LOAD FREQUENCY CONTROL.
REACTIVE POWER VOLTAGE CONTROL.
Methods used for solving both the problems are as follows:
 PF CONTROL :>This helps in controlling the frequency and real power
exchange through the outgoing lines.
 QV CONTROL:>This helps in controlling the voltage |Vi|.
 AUTOMATIC LOAD FREQUENCY CONTROL:>This is used to control the real
power output of generators within a prescribed area in response to changes in
system frequency and line loadings in order to maintain the system frequency
and interchange of power .
CONTROL OF REACTIVE POWER AND POWER FACTOR
 REACTIVE POWER CONTROL:>Interconnector transformers are used for the var
interchange in the power system. When the taps of transformers are changed
in the ring main circulatory current flows through it so the var distribution is
affected with the condition that reactance to resistance ratio should be high
for the ring circuit otherwise active power distribution will be there.
 POWER FACTOR CONTROL:>Power factor can be controlled by following ways:
1)SYNCHRONUS MACHINES- When they are run as overexcited synchronous
motor they supply leading reactive KVA to improve the p.f and hence the voltage
regulation of the system. When operated on no load only for p.f correction they
are called as synchronous compensators.
2)PHASE ADVANCERS- For improving the p.f of industrial motors Lebano
exciter and Scherbius type phase advancers are used.
3)SHUNT CAPACITORS- Its corrective capacity is the square of applied voltage
& varies directly as the frequency and their capacity can be varied only by
changing the no. of units. They are located near the induction motor apparatus
and power losses are low as compared to other methods used. Also they can’t be
used at full load and no load for efficient operation.
4) SERIES CAPACITORS- They are used to reduce the reactance between source
and distribution location so gives a better voltage regulation on lagging power
factor loads and to give better power transfer. A gap along with a C.B is set in
parallel to flashover when the voltage increases 2-4 times the normal rated
value.
INTERCONNECTOR CONTROL
 Interconnection of power station is done to have the reliability and also power transfer can be done
from any station depending on the requirement.
 Some stations can run at unity p.f and some at lagging p.f giving the reactive power.
 A large change in load change the phase angle of one station w.r.t other which results in the flow of
synchronising power.
 When the resistance and reactance of interconnector are numerically equal the synchronising power
becomes maximum.
 Power flow through the interconnector is proportional to its reactance and share the total load in
proportion to their impedance value.
 Load sharing trough interconnector are done by in phase and quadrature voltage control.
FREQUENCY TIES
 Frequency ties which are the form of frequency convertors are required when the systems of different
frequencies are to be tied together.
 Frequency ties are of following types:
1)A SYNCHRONUS MOTOR – SYNCHRONUS ALTERNATOR SET :It forms a rigid frequency tie between the two systems
and the load over each set is controlled by adjusting input the prime mover at the stations.
2) AN INDUCTION MOTOR – SYNCHRONUS ALTERNATOR SET : It do not form a rigid frequency tie between the two
system but as load varies frequency also vary owing to slip of induction motor.
3) SYNCHRONUS CONVERTOR SET – It consists of two rotary convertor operated in series .First one converts ac to
dc supply and the second dc to ac of the frequency of second power system . Load control can be arranged at
convertor and it has wide range of frequency ratio.
4)DC LINK – Large power system with the different frequencies can be interconnected using high power rectifiers
at each end and the dc link in between them . The dc link do not carry do not carry wattles power or reactive
power from one system to another.
SUPERVISORY CONTROL
 It is defined as control of electrical apparatus from the place other than apparatus installed.
 It enables the remote control of apparatus, indicates the position –ON/OFF, enables to transmit metering at
various distant substations to be controlled.
 It may use the pilot wires or telephone channels or carrier current or microwave radio for transmitting
information and operating switches.
 Operation performed by supervisory control may be opening and closing of C.B and isolators , indication of
C.B operation, transformer tap changing, telemetering indicating metre readings centrally by transferring
information from various substations, showing the position of water intake gates, starting equipments ,
speed and excitation control etc.
 Its applications results in advantages in the manual operation and in unattended automatic stations. It helps
in maintaining services, under emergency conditions , by giving the operator a complete picture of entire
system at all the times.
LINE COMPENSATION
 Long distance EHV(extra high voltage) ac transmission system require the use
of series capacitors and shunt reactors to artificially reduce the series
reactance and shunt susceptance of the lines and act as line compensation.
 Their use results in improving the system stability and voltage control ,in
increasing the efficiency of power transmission , facilititating line
energisation and reducing temporary and transient overvoltages.
Line compensation Advantages
 This is done to control the reactive var flow control.
 The advantages of using line compensation methods in the power system are
 Power transmission capability is increased
 Power factor of the system is improved.
 The voltage regulation is minimum.
Types of line compensation
 There are two types of line compensation
• Series compensation
• Shunt compensation
Series compensation
 Series capacitors are used to increase the transmission capability and they are
economical for distances less than 300km.
 P=(V*V)/(Xl-Xc) where P means power transmitted, Xl is the inductive
reactance and Xc is the capacitive reactance.
 Hence as Xc increases implies P increases.
 To achieve surge impedance loading switching of the capacitive banks is
done.
Shunt compensation
To compensate a shunt capacitor is connected which draws current leading the source voltage.
The net results in improvement of power factor.
Shunt inductors are used when there is a requirement of supply of leading vars in the power
system.
It improves the damping to power oscillations.
Series & Shunt Compensation Schemes
for ac Transmission Systems
 There can be a number of arrangements of connecting capacitors and reactors
in the system for compensation.
 The assumptions made are :
1) The capacitor banks and reactors are not more than two per line section,
2) the capacitors are located at line section ends or at the midpoints and the
reactors are located at section ends.
Power System Control And Line Compensation
Comparative Examination of Compensation
Effectiveness of the symmetrical schemes
Evaluation of compensation effectiveness can be made in two ways:-
1) For assigned total Mvars of series capacitors and shunt reactors ,determine
the transmission capabilities at the stability limit of the systems differing only
by compensation schemes;
2) For an assigned transmission capacity, determine the required Mvars of the
series and shunt compensation for various schemes.
Modern practice:
3.1 STATCOM
Static Synchronous Compensator (STATCOM) is a part of the Flexible Alternating Current Transmission
systems (FACTS) device family. They are fast acting, precise, and adjustable amount of reactive power
to the ac power system to which they are connected.
STATCOMs can be used for Voltage regulation at the receiver end of ac transmission lines, thus
replacing banks of shunt capacitors. When used for this purpose, STATCOMs offer a number of
advantages over banks of shunt capacitors, such as much tighter control of the voltage compensation
at the receiver end of the ac transmission line and increased line stability during load variations.
STATCOMs are commonly used for dynamic power factor correction (i.e., dynamic reactive power
compensation) in industrial plants operating with large random peaks of reactive power demand and
also maintains the power Quality in premises. STACOMs increase the power factor of the plant,
minimise the voltage fluctuations at the plant input (which prevents damage to the equipment), and
reduce the plant’s operating costs.
References
1. M V Deshpande
2. I.J Nagrath and Kothari
3. C.L Wadhwa
{THANK YOU}

More Related Content

PPTX
Reactive power management and voltage control by using statcom
PDF
Introduction to reactive power control in electrical power
PPTX
Different method of frequency and voltage control
PPTX
INTERLINE FLOW CONTROLLER
PPTX
Multi terminal dc systems (mtdc)
PPTX
Electrical Machines - II
PPTX
Loading Capability Limits of Transmission Lines
PPTX
Economic dispatch
Reactive power management and voltage control by using statcom
Introduction to reactive power control in electrical power
Different method of frequency and voltage control
INTERLINE FLOW CONTROLLER
Multi terminal dc systems (mtdc)
Electrical Machines - II
Loading Capability Limits of Transmission Lines
Economic dispatch

What's hot (20)

PPTX
Protection and control of Microgrid
PPTX
Types of relay
PPTX
PPTX
Unit 5 Economic Load Dispatch and Unit Commitment
PDF
Chapter 06 - Generation of High Direct Current Voltages
PDF
Full transformer
PPT
Basic types of facts controllers
PPT
Three phase ac voltage controllers
PPTX
induction generator final.pptx
PPTX
Harmonics and mitigation techniques
PPT
Power Flow in a Transmission line
PPTX
Streamer theory
PPTX
Power electronic converter in wind turbine
PPTX
Fc tcr.newpptx
PPTX
Power quality disturbances
PPTX
GENERATING OF HIGH ALTERNATING VOLTAGE
PDF
Facts unit 2
PPTX
Protective relays
Protection and control of Microgrid
Types of relay
Unit 5 Economic Load Dispatch and Unit Commitment
Chapter 06 - Generation of High Direct Current Voltages
Full transformer
Basic types of facts controllers
Three phase ac voltage controllers
induction generator final.pptx
Harmonics and mitigation techniques
Power Flow in a Transmission line
Streamer theory
Power electronic converter in wind turbine
Fc tcr.newpptx
Power quality disturbances
GENERATING OF HIGH ALTERNATING VOLTAGE
Facts unit 2
Protective relays
Ad

Similar to Power System Control And Line Compensation (20)

PPTX
Frequency control & Voltage control.pptx
PPTX
Reactive Power Control and Methodes to control it
PPT
Power control
PPT
Power control in power systems
PPTX
Methods of Voltage Control
PDF
Power electronics application: FACTS controller
PPTX
Reactive power consumption in modern power system
PPTX
Unit 2 Reactive Power Management
PDF
Evolve the Controller for Static Synchronous Series Compensator Based on Cont...
PPTX
Power systems voltage and power control
PPSX
Basic Electrical of Power plant , SLD , Excitation
PPTX
Reactive power compensation
DOCX
Thyristor switched capacitor
DOCX
Substation equipment and its function 2
PPTX
STATIC VAR COMPENSATION (STATCOM) OF FLEXIBLE AC TRANSMISSION SYSTEM
PDF
Flexible Ac Transmission Systems 2Mark Materials and Question Bank
PDF
PPTX
Excitation Systems.pptx
PDF
Introduction
PDF
Reactive power compesation using static syncronous series compensator-A Review
Frequency control & Voltage control.pptx
Reactive Power Control and Methodes to control it
Power control
Power control in power systems
Methods of Voltage Control
Power electronics application: FACTS controller
Reactive power consumption in modern power system
Unit 2 Reactive Power Management
Evolve the Controller for Static Synchronous Series Compensator Based on Cont...
Power systems voltage and power control
Basic Electrical of Power plant , SLD , Excitation
Reactive power compensation
Thyristor switched capacitor
Substation equipment and its function 2
STATIC VAR COMPENSATION (STATCOM) OF FLEXIBLE AC TRANSMISSION SYSTEM
Flexible Ac Transmission Systems 2Mark Materials and Question Bank
Excitation Systems.pptx
Introduction
Reactive power compesation using static syncronous series compensator-A Review
Ad

Recently uploaded (20)

PPTX
Infosys Presentation by1.Riyan Bagwan 2.Samadhan Naiknavare 3.Gaurav Shinde 4...
PDF
Enhancing Cyber Defense Against Zero-Day Attacks using Ensemble Neural Networks
PPT
Mechanical Engineering MATERIALS Selection
PPTX
MET 305 2019 SCHEME MODULE 2 COMPLETE.pptx
PDF
R24 SURVEYING LAB MANUAL for civil enggi
PPTX
OOP with Java - Java Introduction (Basics)
DOCX
573137875-Attendance-Management-System-original
PPTX
Recipes for Real Time Voice AI WebRTC, SLMs and Open Source Software.pptx
PDF
Embodied AI: Ushering in the Next Era of Intelligent Systems
PPTX
Sustainable Sites - Green Building Construction
PPTX
Construction Project Organization Group 2.pptx
PDF
Digital Logic Computer Design lecture notes
PPTX
Engineering Ethics, Safety and Environment [Autosaved] (1).pptx
PDF
Mohammad Mahdi Farshadian CV - Prospective PhD Student 2026
PDF
Mitigating Risks through Effective Management for Enhancing Organizational Pe...
PPTX
Welding lecture in detail for understanding
PPTX
M Tech Sem 1 Civil Engineering Environmental Sciences.pptx
PPTX
Lecture Notes Electrical Wiring System Components
PDF
July 2025 - Top 10 Read Articles in International Journal of Software Enginee...
PPTX
bas. eng. economics group 4 presentation 1.pptx
Infosys Presentation by1.Riyan Bagwan 2.Samadhan Naiknavare 3.Gaurav Shinde 4...
Enhancing Cyber Defense Against Zero-Day Attacks using Ensemble Neural Networks
Mechanical Engineering MATERIALS Selection
MET 305 2019 SCHEME MODULE 2 COMPLETE.pptx
R24 SURVEYING LAB MANUAL for civil enggi
OOP with Java - Java Introduction (Basics)
573137875-Attendance-Management-System-original
Recipes for Real Time Voice AI WebRTC, SLMs and Open Source Software.pptx
Embodied AI: Ushering in the Next Era of Intelligent Systems
Sustainable Sites - Green Building Construction
Construction Project Organization Group 2.pptx
Digital Logic Computer Design lecture notes
Engineering Ethics, Safety and Environment [Autosaved] (1).pptx
Mohammad Mahdi Farshadian CV - Prospective PhD Student 2026
Mitigating Risks through Effective Management for Enhancing Organizational Pe...
Welding lecture in detail for understanding
M Tech Sem 1 Civil Engineering Environmental Sciences.pptx
Lecture Notes Electrical Wiring System Components
July 2025 - Top 10 Read Articles in International Journal of Software Enginee...
bas. eng. economics group 4 presentation 1.pptx

Power System Control And Line Compensation

  • 1. POWER SYSTEM CONTROL AND LINE COMPENSATION Submitted by Roll no. 1120810(E-6) and 1120508 (E-2)
  • 2. CONTENTS:-  Introduction  Voltage control  Power system control  Control of reactive power and power factor  Interconnected control and frequency ties  Supervisory control  Line compensation  Series compensation  Series and shunt compensation schemes for ac transmission system
  • 3. Introduction  Power system control and line compensation are essential for the effective working of power system.  Voltage ,frequency and power factor are the main items to be controlled.  To get the desired voltage at the consumer end voltage control is necessary.  Frequency control is done to form a synchronous link between two systems having different frequencies.  The control of reactive vars will automatically control the power factor of the system.  Nowadays Supervisory control for the power system is done from the main control room.
  • 4. Voltage Control  The voltage control in power system is necessary mainly in the following stages. 1. Generating end. 2. Transmission lines. 3. Receiving end.
  • 5. Generating End Voltage Control Methods Regulators using magnetic amplifiers Electronic voltage regulators Amplidyne control Transistor voltage regulator Thyristor automatic voltage regulator
  • 6. SMALL DESCRIPTION ABOUT THE MODERN VOLTAGE REGULATORS USED FOR CONTROLLING ALTERNATOR VOLTAGE.  REGULATORS USING MAGNETIC AMPLIFIERS:> If the output voltage of the alternator changes to a value other than the reference value then the ampere turns of the control winding (combination of two dc windings arranged in opposition on the core to have opposing magnetic field effects) changes which changes the field current of exciter of alternator to maintain the constant output voltage.  ELECTRONIC VOLTAGE REGULATORS:> It consists of bridge circuit with thyratron valves which control the field of exciter.  AMPLIDYNE CONTROL:> Exciter field current of the alternator is controlled using amplidyne.  TRANSISTOR VOLTAGE REGULATOR:> Transistorised circuitary is used for the field current control.  THYRISTOR AUTOMATIC VOLTAGE REGULATOR:> These are the completely static voltage regulators having very fast response and they use high current thyristors.
  • 7. EXCITATION SYSTEM USED FOR ALTERNATORS DIRECT SELF EXCITATION INDIRECT SELF EXCITATION SEPARATE EXCITATION  INDIRECT SELF EXCITATION:>In this the output of the thyristor regulator control the field of exciter(can be ac with rotating rectifiers in brushless alternator arrangement) and the supply voltage to the regulator is fed fron generator itself.This system is used mainly for alternators of 100KVA to several MVA.  SEPARATE EXCITATION SYSTEM:> In this a pilot exciter act as a source to the thyristor regulator which controls the amin excitor and supplies the field of main generator . This system is used mainly for alternators of 100KVA to very lagre size turbo alternators.
  • 10. VOLTAGE REGULATION OF TRANSMISSION LINE Methods used for regulation of T-line is as follows:  TAP CHANGING TRANSFORMERS:> Voltage level at the substation or the load points can be adjusted to desired level on load as well as off load.  BOOSTER TRANSFORMER:> They are used to raise the potential at a point away from the main transformer and are having a capacity of 10% to 20% of that of main transformers. Selective load dispatching is necessary when stations in a systems are interconnected to avoid the overloading of lines which can be done using devices given below.  IN PHASE VOLTAGE BOOSTER TRANSFORMER:>It is used to inject voltage in phase with the line voltage.  QUADRATURE VOLTAGE BOOSTER TRANSFORMER:>It is used to inject voltage at right angle to the line voltage.  INDUCTION REGULATOR:>This is similar to that of wound rotor induction motor in which the rotor is not free to rotate and rotor winding is connected in series with the stator winding .
  • 13. VOLTAGE REGULATION OF TRANSMISSION LINE On Load Tap changing transformers Booster transformer Phase shifting transformer Induction Regulator Servo control Static voltage control
  • 14.  AUTOMATIC VOLTAGE CONTROL :> IT is affected by servo control having three principal elements 1.Voltage regulating relay. 2.Intermediate relay. 3.Motor drive. STATIC VOLTAGE CONTROL:>It is being used for high voltage transmission line upto 330 KV. The static network compensator employ ac saturating reactor for the reactive power control and can be used in conjunction with the static compensator which have following advantages: o Instantaneous overvoltage prevention. o Prevents loss of synchronism. o Increases the capacity of transmission line. o Increase in the stability limit. o Possibility to increase transmission line length increases.
  • 15. POWER SYSTEM CONTROL The main problems of control are : ACTIVE POWER LOAD FREQUENCY CONTROL. REACTIVE POWER VOLTAGE CONTROL. Methods used for solving both the problems are as follows:  PF CONTROL :>This helps in controlling the frequency and real power exchange through the outgoing lines.  QV CONTROL:>This helps in controlling the voltage |Vi|.  AUTOMATIC LOAD FREQUENCY CONTROL:>This is used to control the real power output of generators within a prescribed area in response to changes in system frequency and line loadings in order to maintain the system frequency and interchange of power .
  • 16. CONTROL OF REACTIVE POWER AND POWER FACTOR  REACTIVE POWER CONTROL:>Interconnector transformers are used for the var interchange in the power system. When the taps of transformers are changed in the ring main circulatory current flows through it so the var distribution is affected with the condition that reactance to resistance ratio should be high for the ring circuit otherwise active power distribution will be there.  POWER FACTOR CONTROL:>Power factor can be controlled by following ways: 1)SYNCHRONUS MACHINES- When they are run as overexcited synchronous motor they supply leading reactive KVA to improve the p.f and hence the voltage regulation of the system. When operated on no load only for p.f correction they are called as synchronous compensators. 2)PHASE ADVANCERS- For improving the p.f of industrial motors Lebano exciter and Scherbius type phase advancers are used. 3)SHUNT CAPACITORS- Its corrective capacity is the square of applied voltage & varies directly as the frequency and their capacity can be varied only by changing the no. of units. They are located near the induction motor apparatus and power losses are low as compared to other methods used. Also they can’t be used at full load and no load for efficient operation.
  • 17. 4) SERIES CAPACITORS- They are used to reduce the reactance between source and distribution location so gives a better voltage regulation on lagging power factor loads and to give better power transfer. A gap along with a C.B is set in parallel to flashover when the voltage increases 2-4 times the normal rated value.
  • 18. INTERCONNECTOR CONTROL  Interconnection of power station is done to have the reliability and also power transfer can be done from any station depending on the requirement.  Some stations can run at unity p.f and some at lagging p.f giving the reactive power.  A large change in load change the phase angle of one station w.r.t other which results in the flow of synchronising power.  When the resistance and reactance of interconnector are numerically equal the synchronising power becomes maximum.  Power flow through the interconnector is proportional to its reactance and share the total load in proportion to their impedance value.  Load sharing trough interconnector are done by in phase and quadrature voltage control.
  • 19. FREQUENCY TIES  Frequency ties which are the form of frequency convertors are required when the systems of different frequencies are to be tied together.  Frequency ties are of following types: 1)A SYNCHRONUS MOTOR – SYNCHRONUS ALTERNATOR SET :It forms a rigid frequency tie between the two systems and the load over each set is controlled by adjusting input the prime mover at the stations. 2) AN INDUCTION MOTOR – SYNCHRONUS ALTERNATOR SET : It do not form a rigid frequency tie between the two system but as load varies frequency also vary owing to slip of induction motor. 3) SYNCHRONUS CONVERTOR SET – It consists of two rotary convertor operated in series .First one converts ac to dc supply and the second dc to ac of the frequency of second power system . Load control can be arranged at convertor and it has wide range of frequency ratio. 4)DC LINK – Large power system with the different frequencies can be interconnected using high power rectifiers at each end and the dc link in between them . The dc link do not carry do not carry wattles power or reactive power from one system to another.
  • 20. SUPERVISORY CONTROL  It is defined as control of electrical apparatus from the place other than apparatus installed.  It enables the remote control of apparatus, indicates the position –ON/OFF, enables to transmit metering at various distant substations to be controlled.  It may use the pilot wires or telephone channels or carrier current or microwave radio for transmitting information and operating switches.  Operation performed by supervisory control may be opening and closing of C.B and isolators , indication of C.B operation, transformer tap changing, telemetering indicating metre readings centrally by transferring information from various substations, showing the position of water intake gates, starting equipments , speed and excitation control etc.  Its applications results in advantages in the manual operation and in unattended automatic stations. It helps in maintaining services, under emergency conditions , by giving the operator a complete picture of entire system at all the times.
  • 21. LINE COMPENSATION  Long distance EHV(extra high voltage) ac transmission system require the use of series capacitors and shunt reactors to artificially reduce the series reactance and shunt susceptance of the lines and act as line compensation.  Their use results in improving the system stability and voltage control ,in increasing the efficiency of power transmission , facilititating line energisation and reducing temporary and transient overvoltages.
  • 22. Line compensation Advantages  This is done to control the reactive var flow control.  The advantages of using line compensation methods in the power system are  Power transmission capability is increased  Power factor of the system is improved.  The voltage regulation is minimum.
  • 23. Types of line compensation  There are two types of line compensation • Series compensation • Shunt compensation
  • 24. Series compensation  Series capacitors are used to increase the transmission capability and they are economical for distances less than 300km.  P=(V*V)/(Xl-Xc) where P means power transmitted, Xl is the inductive reactance and Xc is the capacitive reactance.  Hence as Xc increases implies P increases.  To achieve surge impedance loading switching of the capacitive banks is done.
  • 25. Shunt compensation To compensate a shunt capacitor is connected which draws current leading the source voltage. The net results in improvement of power factor. Shunt inductors are used when there is a requirement of supply of leading vars in the power system. It improves the damping to power oscillations.
  • 26. Series & Shunt Compensation Schemes for ac Transmission Systems  There can be a number of arrangements of connecting capacitors and reactors in the system for compensation.  The assumptions made are : 1) The capacitor banks and reactors are not more than two per line section, 2) the capacitors are located at line section ends or at the midpoints and the reactors are located at section ends.
  • 28. Comparative Examination of Compensation Effectiveness of the symmetrical schemes Evaluation of compensation effectiveness can be made in two ways:- 1) For assigned total Mvars of series capacitors and shunt reactors ,determine the transmission capabilities at the stability limit of the systems differing only by compensation schemes; 2) For an assigned transmission capacity, determine the required Mvars of the series and shunt compensation for various schemes.
  • 29. Modern practice: 3.1 STATCOM Static Synchronous Compensator (STATCOM) is a part of the Flexible Alternating Current Transmission systems (FACTS) device family. They are fast acting, precise, and adjustable amount of reactive power to the ac power system to which they are connected. STATCOMs can be used for Voltage regulation at the receiver end of ac transmission lines, thus replacing banks of shunt capacitors. When used for this purpose, STATCOMs offer a number of advantages over banks of shunt capacitors, such as much tighter control of the voltage compensation at the receiver end of the ac transmission line and increased line stability during load variations. STATCOMs are commonly used for dynamic power factor correction (i.e., dynamic reactive power compensation) in industrial plants operating with large random peaks of reactive power demand and also maintains the power Quality in premises. STACOMs increase the power factor of the plant, minimise the voltage fluctuations at the plant input (which prevents damage to the equipment), and reduce the plant’s operating costs.
  • 30. References 1. M V Deshpande 2. I.J Nagrath and Kothari 3. C.L Wadhwa