Cisco Optical Networking – Chromatic Dispersion
calculation.
Cisco Support Community
Expert Series Webcast
Question1
Have you ever had deal with DWDM
Cisco ONS devices?
1. Yes
2. No
3. Cisco have such platforms?
• Chromatic Dispersion
• Measurement of CD in real Fiber
• Sample of calculation in CTP
• Polarization Mode Dispersion
Content of presentation
Chromatic
Dispersion
•Chromatic Dispersion (CD) – is based on effect of
impulse broadening during passing through optical fiber.
•Polarization Mode Dispersion - a temporary difference
between the polarization components of the same signal.
Optical Dispersion types:
• Optical pulse time-expanded by passing through the
optical fiber. This process triggers limitation of bandwidth
throughput or maximum transition distance with constant
bandwidth.
• Chromatic Dispersion is fiber characteristic with is
measured in ps/km*nm and depends on wavelength.
• To compensate dispersion used pre-compensation and
post-compensation techniques. Dispersion compensators is
based on negative dispersion fiber.
Chromatic Dispersion (CD)
Different cables have different CD depending on internal
construction
Typical CD values of different fibers
Fiber type Normal dispersion at 1550 nm
measured in ps/km-nm
Single Mode Fiber (SMF) 17
E-Large Effective area fiber
(ELEAF)
4
TrueWave RS (TW-RS) 4.2
Dispersion shifted fiber (DSF) -0.33
• Cisco DCU compensators uses
fiber loops with negative
dispersion fiber.
• Attenuation of DCU varieties
from 2.1db to 8.8 db.
•Compensation Level (ps/nm)
varieties from 100ps/nm to 1950
ps/nm
Cisco ONS 15216 DCU modules
DCU chassis PN:
15216-DCU-SA=
DCU module PN:
15216-DCU-XXXX=
Optical spool produced and measured in Thailand,
completed in in hard case in Denmark.
For Sample this DCU has 1950 psnm nominal, but in real
how we see in report it has 1957,33 ps/nm. Insertion loss
6.97db vs 8.8db in data sheet.
What is inside DCU module?
•Disadvantage of use DCU in network is that DC add
significant attenuationloss. This is due to difference of
coupling transition and fiber and fiber used in DCU.
• Advantage of use compensators is that DCU limit
nonlinear effects. Different dispersion profile result in a
phase mismatch, witch prevent from FWM happening.
Pluses and minuses of use DCU
Values of CD Tolerance XFP:
• Fixed Wavelength XFP
-500 to +1100 ps/nm
• Tunable Wavelenght XFP
-400 to +1300 ps/nm
CD Tolerance of different XFP 10G modules
Values of CD Tolerance SFP+:
• Fixed Wavelength XFP
-500 to +1100 ps/nm
• Tunable Wavelenght XFP
-400 to +1300 ps/nm
CD Tolerance of different SFP+ 10G modules
• Use of fixed wavelength SFP+XFP has disadvantages in
case failure. Fixed wavelength could be replaced by tunable
module or the SAME wavelength module.
• GLP Price Discount could be higher for tunable modules
that for fixed. Contact to your Cisco CAM.
• In future line DWDM network could be upgraded to
colorless or directionless.
Comparison of SFP+ vs XFP modules
Single-Shelf DCU Application
East-to-West and West-to-East
Samples of use DCU modules
Cascaded DCU Shelf per
Direction
DCU Placed Between
Wavelength Selective Switch
(WSS) and Amplifier
CD Tolerance of different SFP+ 10G modules
DWDM network based on 10G services called coherent
networks and networks based on 100G and higher services
called non-coherent networks.
Design coherent networks depends on compensation
systems. Non-coherent networks in most (but not in all)
cases doesn’t depends on compensation systems because
tolerance of recoveries around 94 000 ps/nm for 200G. For
example 94 000ps/nm is equivalent to 5200 km with
18ps/nm-km.
CD Tolerance of 10G, 200G, 400G modules
Measurement
of CD of real
fiber
What parameters are measured:
• dispersion coefficient values measured at specified
wavelength
• dispersion maximum over specified range of wavelengths
• zero dispersion wavelength and dispersion slope at this
wavelength
CD measurement, Introduction
Both methods measure propagation delay (or group delay) at selected
wavelength and, from the measured delay versus wavelength data, interpolate
the delay for other wavelength not directly measured by using numerical fitting
algorithms.
• Phase Shift – method of comparison of test signal and reference signal used to
modulate the input signal. The phase difference is performed versus wavelength
over the entire wavelength range of source.
• Pulse Delay -
Measurement methods (Phase Shift vs Pulse
Delay )
Phase Shift advantages:
 high accuracy measurement
 high dynamic range (40 db+) (>15 db
higher than the Pulse Delay method)
 high measurement reliability
 compatible with non-biderectional
components (such EDFA amplifiers)
Phase Shift Method
Phase Shift disentangles:
 measurement time can depend on
number of data ponts
 requires two units
 dispersion versus length info not
provided
Fiber length must be known to calculate
the average CD coefficient
Group Delay advantages:
 require access to only one end of link
 detects regions of different dispersion
within a link? As it can analyze reflections
at intermediate points (only if reflectance
are present mid-span)
Combines an OTDR allowing a
simultaneous distance and loss
measurement
Group Delay Method
Group Delay disentangles:
 distance range is limited by the end
reflection: higher reflectance? The longer
distance. Not suitable for APC
connections installed.
 Not suitable for long-haul or high-loss
fiber link (>30db)
 not compatible with non-biderectional
components (EDFA amplifiers)
100G/100G/400G Cards now
have advanced measurement
method build in.
100G/100G/400G Cards CD measurement
Sample of
calculation in
CTP, XLS
Need to design network with
requirements:
• 5 sites
• 4 channel 10GE
• fiber used is SMF G652
In this example we will not
consider design of multiplexing,
adddrop and amplification
systems.
Real Sample of Calculation. Planning of DCU
Scheme of compensation in DWDM network
In this step we will make:
• Start – “Project Creation Wizard”
• Start – “Run the Network Wizard Now”
• Create circuit – “Create Net Point-to-Point Demand”
• Start – “Network Analyze”
• Go to – “Summary” –> “Optical Reports”
Lets start to work in CTP. Step 1 – Preparation.
Project Creation Wizard
Run the Network Wizard Now
In this section we will not
cover types of transponders
and so on, just create circuit.
Create Circuits
DWDM trunk type we are changing to Tunable SFP+. It is not matter
what type of coding (FECEFECNO-FEC), it doesn’t add any price for
total BOM. Coding (FECEFECNO-FEC) in 10G networks no licensable
by Cisco. After this choice we exactly know CD tolerance of trunk ports.
Edit trunk SFP manually to SFP+ Tunable C
band
 Report shows per channel CD calculation at the end of
circuit in BOTH directions. Chromatic Dispersion
compensation systems is separate per each direction.
 Cisco Transport Planner (CTP) use value 1100ps/nm for
Tunable SFP+, but in data sheet 1300ps/nm. Advantage of
use CTP is that it has fundmargin in reports.
 CTP doesn’t use any fiber characteristicfunction of DC
depending on wavelength.
 If Residual CD cross CD Robustness (CD tolerance) value
than CTP triggers Single-Channel NLE Status RED. Later will
discus situation with Single-Channel NLE Status RED.
 CTP maximum optimally calculates DCU unites. In case of
alarms power EOL , EOS you can manually change DCU to
lower values, in most cases it helps to improve power SOL
value.
Analyze “Optical Report”
• Click on Site 1-5,
choose “Layout”
• Click on Site 1-5,
choose
“Functional view”
Lets do that for
every Site and
draw big topology
per each direction
Lets understand what CTP calculated
Site-1 Functional view
Site-1 Functional view
Site-3 Functional view
Site-4 Functional view
Site-5 Functional view
 In attach XLS based calculation of DC of Channel
between Site-1 and Site-5
XLS based DC Calculation
Site ID DCU-XXXX CD value Site ID DCU-XXXX CD value Site ID DCU-XXXXCD value Site ID DCU-XXXXCD value
Site-1 none 0 Site-5-B none 0 Site-1 none 0 Site-5-B none 0
Fiber length 85 Fiber length 50 Fiber length 85 Fiber length 50
Fiber CD total 1402,5 Fiber CD total 825 Fiber CD total 1402,5 Fiber CD total 825
CD after fiber 1402,5 CD after fiber 825 CD after fiber 1402,5 CD after fiber 825
Site-2-B 1350 Site-4-A 450 Site-2-B 1350 Site-4-A 450
52,5 375 52,5 375
Fiber length 90 Fiber length 120 Calculation CD in CTP----------> Fiber length 90 Fiber length 120
Fiber CD total 1485 Fiber CD total 1980 Fiber CD total 1485 Fiber CD total 1980
CD after fiber 1537,5 CD after fiber 2355 CD after fiber 1537,5 CD after fiber 2355
Site-3-B 1350 Site-3-A 1350 Site-3-B 1350 Site-3-A 1350
187,5 550 187,5 550
Fiber length 120 455 5 This value calculates CTP Fiber length 120 450 5
Fiber CD total 1980 Fiber length 90 But have to be 455, CTP makes errorFiber CD total 1980 Fiber length 90
CD after fiber 2167,5 Fiber CD total 1485 It add aditional DCU-450 CD after fiber 2167,5 Fiber CD total 1485
Site-4-B 1350 CD after fiber 1940 Site-4-B 1350 CD after fiber 1490
450 Site-2-A 1350 450 Site-2-A 1150
550 590 340 This value calculates CTP 550 340
-182,5 Fiber length 85 But have to be 590, CTP makes error -182,5 Fiber length 85
Fiber length 50 Fiber CD total 1402,5 It add aditional DCU-450 Fiber length 50 Fiber CD total 1402,5
Fiber CD total 825 CD after fiber 1992,5 Fiber CD total 825 CD after fiber 1742,5
CD after fiber 642,5 Site-1-A 1350 CD after fiber 642,5 Site-1-A 1350
Site-5-B 550 642,5 392 This value calculates CTP Site-5-B 550 392,5
92,5 But have to be 642, CTP makes error 92,5
It add aditional DCU-450
As result we can see some errors and make some conclutions:
 CTP show in layout or doesn’t show correct DCU values on which based DC results in
“Optical Results” report
 Be care with CTP, use manual calculation to check, also use Forcing Manager to unlock
and clear CD cache calculation.
 Use “Forcing Manager” when you add new circuits in design
 Do not make “Over-Compensation” and “Under-Compensation”, try to have CD of signal
all the time in tolerance window. For example tolerance window for SFP+ Tunable from -
100 to 1100 ps/nm
XLS based DC Calculation
Force to clear CD calculation
Polarization
Mode
Dispersion
Polarization Mode Dispersion - a temporary difference between the polarization
components of the same signal.
Example A - optic cable has ideal dimensions of the X-axis and Y -> the same velocity of
propagation.
Example B - optic cable has different dimensions to the X-axis and Y -> propagation
speed is different.
Polarization Mode Dispersion (PMD)
Causes of PMD:
• The asymmetry of the core or the internal stress caused by the core during production
• Internal stress caused by the core during the installation of optical cable
Polarization Mode Dispersion (PMD)
Cisco DWDM Chromatic Dispertion Calculation in CTP\XLS

More Related Content

PDF
DWDM 101 - BRKOPT-2016
PPTX
Basics of DWDM Technology
PDF
Optical Transport Technologies and Trends
PPTX
Design and Simulation WDM
PDF
Fundamental of dwdm
PDF
Dense wavelength division multiplexing (dwdm) technique
PPTX
TECHNIQUES TO COMBAT OSNR IN DWDM LINKS
PPTX
Mobile Networks Overview (2G / 3G / 4G-LTE)
DWDM 101 - BRKOPT-2016
Basics of DWDM Technology
Optical Transport Technologies and Trends
Design and Simulation WDM
Fundamental of dwdm
Dense wavelength division multiplexing (dwdm) technique
TECHNIQUES TO COMBAT OSNR IN DWDM LINKS
Mobile Networks Overview (2G / 3G / 4G-LTE)

What's hot (20)

PDF
WDM principles
PPT
Pdh and sdh1
PDF
PPTX
SDH Frame Structure
PPTX
OFDM Basics
PPTX
PDF
258116349-DWDM-Basic-Presentation.pdf
PPTX
Packet core network basics
PPTX
4G Mobile Network & Applications
PPTX
Basic of MODBUS Communication/Protocol
PPTX
CWDM vs DWDM Technology
PDF
ROADM Technologies for Flexible - Tbitsec Optical Networks
PDF
DWDM Presentation
PPT
Fundamentals of sdh
PDF
Millimeter wave as the future of 5g
PPTX
Submarine line termination equipment (SLTE) for open cables
PPT
Gpon Fundamentals
PPTX
2 g data call flow
WDM principles
Pdh and sdh1
SDH Frame Structure
OFDM Basics
258116349-DWDM-Basic-Presentation.pdf
Packet core network basics
4G Mobile Network & Applications
Basic of MODBUS Communication/Protocol
CWDM vs DWDM Technology
ROADM Technologies for Flexible - Tbitsec Optical Networks
DWDM Presentation
Fundamentals of sdh
Millimeter wave as the future of 5g
Submarine line termination equipment (SLTE) for open cables
Gpon Fundamentals
2 g data call flow
Ad

Viewers also liked (8)

PDF
Implications of super channels on CDC ROADM architectures
PDF
ADVA Optical Networking and Arista Networks Joint OOLS Demo
PDF
Transforming Packet Networks With Open Optical Transport
PPTX
N-degree ROADM Architecture Comparison: Broadcast-and-Select vs Route-and-Select
PDF
Introducing the Future of Data Center Interconnect Networks
PDF
dwdm
 
PDF
White Box Optics: Will It Kill or Encourage Innovation?
PDF
Direct Detect Optical Layer for Ultimate DCI Flexibility
Implications of super channels on CDC ROADM architectures
ADVA Optical Networking and Arista Networks Joint OOLS Demo
Transforming Packet Networks With Open Optical Transport
N-degree ROADM Architecture Comparison: Broadcast-and-Select vs Route-and-Select
Introducing the Future of Data Center Interconnect Networks
dwdm
 
White Box Optics: Will It Kill or Encourage Innovation?
Direct Detect Optical Layer for Ultimate DCI Flexibility
Ad

Similar to Cisco DWDM Chromatic Dispertion Calculation in CTP\XLS (20)

PDF
RZ based dispersion compensation technique in dwdm system for broadband spectrum
PDF
RZ based dispersion compensation technique in dwdm system for broadband spectrum
PDF
Iisrt 1-rz based dispersion compensation technique in dwdm system for broadba...
PPT
A System's View of Metro and Regional Optical Networks
PDF
IRJET- Performance Analysis of IP Over Optical CDMA System based on RD Code
PDF
COHERENT OPTICAL TRANSCEIVERS – CURRENT CAPABILITIES AND FUTURE POSSIBILITIES
PDF
Alignment in DDA Distributed Access Architecture_4-28-2020
PDF
White Paper-Evolution from 10Gbps to 100Gbps for a Metro Network-hs
PDF
OFC 2019 - 100G DWDM DCI/Metro Network Solutions - Debating alternatives to ...
PDF
Simulation and Performance Analysis of Dispersion Compensation using DCF in P...
PDF
Towards Terabit per Second Optical Networking
PDF
101483423-Fiber-Characterization-Training.pdf
PDF
PON testing.pdf
PDF
Performance Evaluation of DCF Length for High Scalability NG-PON2
PPTX
Fiber Optic Wavelength Division Multiplexing Training - Mericler 2024.pptx
PPTX
Zero Dispersion Modes and its Effects on Characterization of MMF Chromatic Di...
PDF
OIF on 400G for Next Gen Optical Networks Conference
PDF
Comparatively analysis of FBG optical fiber in 25 & 35 Gbps DCDM based Commun...
PDF
FTTx - GPON technology.pdf
PPTX
it's just colours......... +physics.pptx
RZ based dispersion compensation technique in dwdm system for broadband spectrum
RZ based dispersion compensation technique in dwdm system for broadband spectrum
Iisrt 1-rz based dispersion compensation technique in dwdm system for broadba...
A System's View of Metro and Regional Optical Networks
IRJET- Performance Analysis of IP Over Optical CDMA System based on RD Code
COHERENT OPTICAL TRANSCEIVERS – CURRENT CAPABILITIES AND FUTURE POSSIBILITIES
Alignment in DDA Distributed Access Architecture_4-28-2020
White Paper-Evolution from 10Gbps to 100Gbps for a Metro Network-hs
OFC 2019 - 100G DWDM DCI/Metro Network Solutions - Debating alternatives to ...
Simulation and Performance Analysis of Dispersion Compensation using DCF in P...
Towards Terabit per Second Optical Networking
101483423-Fiber-Characterization-Training.pdf
PON testing.pdf
Performance Evaluation of DCF Length for High Scalability NG-PON2
Fiber Optic Wavelength Division Multiplexing Training - Mericler 2024.pptx
Zero Dispersion Modes and its Effects on Characterization of MMF Chromatic Di...
OIF on 400G for Next Gen Optical Networks Conference
Comparatively analysis of FBG optical fiber in 25 & 35 Gbps DCDM based Commun...
FTTx - GPON technology.pdf
it's just colours......... +physics.pptx

Recently uploaded (20)

PDF
PREDICTION OF DIABETES FROM ELECTRONIC HEALTH RECORDS
PDF
null (2) bgfbg bfgb bfgb fbfg bfbgf b.pdf
PPTX
Fundamentals of safety and accident prevention -final (1).pptx
PPTX
Software Engineering and software moduleing
PDF
22EC502-MICROCONTROLLER AND INTERFACING-8051 MICROCONTROLLER.pdf
PPT
INTRODUCTION -Data Warehousing and Mining-M.Tech- VTU.ppt
PDF
UNIT no 1 INTRODUCTION TO DBMS NOTES.pdf
PDF
Categorization of Factors Affecting Classification Algorithms Selection
PDF
COURSE DESCRIPTOR OF SURVEYING R24 SYLLABUS
PDF
BIO-INSPIRED ARCHITECTURE FOR PARSIMONIOUS CONVERSATIONAL INTELLIGENCE : THE ...
PDF
EXPLORING LEARNING ENGAGEMENT FACTORS INFLUENCING BEHAVIORAL, COGNITIVE, AND ...
PPTX
communication and presentation skills 01
PDF
737-MAX_SRG.pdf student reference guides
PDF
Soil Improvement Techniques Note - Rabbi
PDF
distributed database system" (DDBS) is often used to refer to both the distri...
PPTX
introduction to high performance computing
PPTX
AUTOMOTIVE ENGINE MANAGEMENT (MECHATRONICS).pptx
PDF
Automation-in-Manufacturing-Chapter-Introduction.pdf
PPTX
Fundamentals of Mechanical Engineering.pptx
PDF
Abrasive, erosive and cavitation wear.pdf
PREDICTION OF DIABETES FROM ELECTRONIC HEALTH RECORDS
null (2) bgfbg bfgb bfgb fbfg bfbgf b.pdf
Fundamentals of safety and accident prevention -final (1).pptx
Software Engineering and software moduleing
22EC502-MICROCONTROLLER AND INTERFACING-8051 MICROCONTROLLER.pdf
INTRODUCTION -Data Warehousing and Mining-M.Tech- VTU.ppt
UNIT no 1 INTRODUCTION TO DBMS NOTES.pdf
Categorization of Factors Affecting Classification Algorithms Selection
COURSE DESCRIPTOR OF SURVEYING R24 SYLLABUS
BIO-INSPIRED ARCHITECTURE FOR PARSIMONIOUS CONVERSATIONAL INTELLIGENCE : THE ...
EXPLORING LEARNING ENGAGEMENT FACTORS INFLUENCING BEHAVIORAL, COGNITIVE, AND ...
communication and presentation skills 01
737-MAX_SRG.pdf student reference guides
Soil Improvement Techniques Note - Rabbi
distributed database system" (DDBS) is often used to refer to both the distri...
introduction to high performance computing
AUTOMOTIVE ENGINE MANAGEMENT (MECHATRONICS).pptx
Automation-in-Manufacturing-Chapter-Introduction.pdf
Fundamentals of Mechanical Engineering.pptx
Abrasive, erosive and cavitation wear.pdf

Cisco DWDM Chromatic Dispertion Calculation in CTP\XLS

  • 1. Kayukov Valeriy Optical System Engineer Step Logic April 15, 2016 Cisco Optical Networking – Chromatic Dispersion calculation. Cisco Support Community Expert Series Webcast
  • 2. Question1 Have you ever had deal with DWDM Cisco ONS devices? 1. Yes 2. No 3. Cisco have such platforms?
  • 3. • Chromatic Dispersion • Measurement of CD in real Fiber • Sample of calculation in CTP • Polarization Mode Dispersion Content of presentation
  • 5. •Chromatic Dispersion (CD) – is based on effect of impulse broadening during passing through optical fiber. •Polarization Mode Dispersion - a temporary difference between the polarization components of the same signal. Optical Dispersion types:
  • 6. • Optical pulse time-expanded by passing through the optical fiber. This process triggers limitation of bandwidth throughput or maximum transition distance with constant bandwidth. • Chromatic Dispersion is fiber characteristic with is measured in ps/km*nm and depends on wavelength. • To compensate dispersion used pre-compensation and post-compensation techniques. Dispersion compensators is based on negative dispersion fiber. Chromatic Dispersion (CD)
  • 7. Different cables have different CD depending on internal construction Typical CD values of different fibers Fiber type Normal dispersion at 1550 nm measured in ps/km-nm Single Mode Fiber (SMF) 17 E-Large Effective area fiber (ELEAF) 4 TrueWave RS (TW-RS) 4.2 Dispersion shifted fiber (DSF) -0.33
  • 8. • Cisco DCU compensators uses fiber loops with negative dispersion fiber. • Attenuation of DCU varieties from 2.1db to 8.8 db. •Compensation Level (ps/nm) varieties from 100ps/nm to 1950 ps/nm Cisco ONS 15216 DCU modules DCU chassis PN: 15216-DCU-SA= DCU module PN: 15216-DCU-XXXX=
  • 9. Optical spool produced and measured in Thailand, completed in in hard case in Denmark. For Sample this DCU has 1950 psnm nominal, but in real how we see in report it has 1957,33 ps/nm. Insertion loss 6.97db vs 8.8db in data sheet. What is inside DCU module?
  • 10. •Disadvantage of use DCU in network is that DC add significant attenuationloss. This is due to difference of coupling transition and fiber and fiber used in DCU. • Advantage of use compensators is that DCU limit nonlinear effects. Different dispersion profile result in a phase mismatch, witch prevent from FWM happening. Pluses and minuses of use DCU
  • 11. Values of CD Tolerance XFP: • Fixed Wavelength XFP -500 to +1100 ps/nm • Tunable Wavelenght XFP -400 to +1300 ps/nm CD Tolerance of different XFP 10G modules
  • 12. Values of CD Tolerance SFP+: • Fixed Wavelength XFP -500 to +1100 ps/nm • Tunable Wavelenght XFP -400 to +1300 ps/nm CD Tolerance of different SFP+ 10G modules
  • 13. • Use of fixed wavelength SFP+XFP has disadvantages in case failure. Fixed wavelength could be replaced by tunable module or the SAME wavelength module. • GLP Price Discount could be higher for tunable modules that for fixed. Contact to your Cisco CAM. • In future line DWDM network could be upgraded to colorless or directionless. Comparison of SFP+ vs XFP modules
  • 14. Single-Shelf DCU Application East-to-West and West-to-East Samples of use DCU modules Cascaded DCU Shelf per Direction DCU Placed Between Wavelength Selective Switch (WSS) and Amplifier
  • 15. CD Tolerance of different SFP+ 10G modules
  • 16. DWDM network based on 10G services called coherent networks and networks based on 100G and higher services called non-coherent networks. Design coherent networks depends on compensation systems. Non-coherent networks in most (but not in all) cases doesn’t depends on compensation systems because tolerance of recoveries around 94 000 ps/nm for 200G. For example 94 000ps/nm is equivalent to 5200 km with 18ps/nm-km. CD Tolerance of 10G, 200G, 400G modules
  • 17. Measurement of CD of real fiber
  • 18. What parameters are measured: • dispersion coefficient values measured at specified wavelength • dispersion maximum over specified range of wavelengths • zero dispersion wavelength and dispersion slope at this wavelength CD measurement, Introduction
  • 19. Both methods measure propagation delay (or group delay) at selected wavelength and, from the measured delay versus wavelength data, interpolate the delay for other wavelength not directly measured by using numerical fitting algorithms. • Phase Shift – method of comparison of test signal and reference signal used to modulate the input signal. The phase difference is performed versus wavelength over the entire wavelength range of source. • Pulse Delay - Measurement methods (Phase Shift vs Pulse Delay )
  • 20. Phase Shift advantages:  high accuracy measurement  high dynamic range (40 db+) (>15 db higher than the Pulse Delay method)  high measurement reliability  compatible with non-biderectional components (such EDFA amplifiers) Phase Shift Method Phase Shift disentangles:  measurement time can depend on number of data ponts  requires two units  dispersion versus length info not provided Fiber length must be known to calculate the average CD coefficient
  • 21. Group Delay advantages:  require access to only one end of link  detects regions of different dispersion within a link? As it can analyze reflections at intermediate points (only if reflectance are present mid-span) Combines an OTDR allowing a simultaneous distance and loss measurement Group Delay Method Group Delay disentangles:  distance range is limited by the end reflection: higher reflectance? The longer distance. Not suitable for APC connections installed.  Not suitable for long-haul or high-loss fiber link (>30db)  not compatible with non-biderectional components (EDFA amplifiers)
  • 22. 100G/100G/400G Cards now have advanced measurement method build in. 100G/100G/400G Cards CD measurement
  • 24. Need to design network with requirements: • 5 sites • 4 channel 10GE • fiber used is SMF G652 In this example we will not consider design of multiplexing, adddrop and amplification systems. Real Sample of Calculation. Planning of DCU Scheme of compensation in DWDM network
  • 25. In this step we will make: • Start – “Project Creation Wizard” • Start – “Run the Network Wizard Now” • Create circuit – “Create Net Point-to-Point Demand” • Start – “Network Analyze” • Go to – “Summary” –> “Optical Reports” Lets start to work in CTP. Step 1 – Preparation.
  • 27. Run the Network Wizard Now
  • 28. In this section we will not cover types of transponders and so on, just create circuit. Create Circuits
  • 29. DWDM trunk type we are changing to Tunable SFP+. It is not matter what type of coding (FECEFECNO-FEC), it doesn’t add any price for total BOM. Coding (FECEFECNO-FEC) in 10G networks no licensable by Cisco. After this choice we exactly know CD tolerance of trunk ports. Edit trunk SFP manually to SFP+ Tunable C band
  • 30.  Report shows per channel CD calculation at the end of circuit in BOTH directions. Chromatic Dispersion compensation systems is separate per each direction.  Cisco Transport Planner (CTP) use value 1100ps/nm for Tunable SFP+, but in data sheet 1300ps/nm. Advantage of use CTP is that it has fundmargin in reports.  CTP doesn’t use any fiber characteristicfunction of DC depending on wavelength.  If Residual CD cross CD Robustness (CD tolerance) value than CTP triggers Single-Channel NLE Status RED. Later will discus situation with Single-Channel NLE Status RED.  CTP maximum optimally calculates DCU unites. In case of alarms power EOL , EOS you can manually change DCU to lower values, in most cases it helps to improve power SOL value. Analyze “Optical Report”
  • 31. • Click on Site 1-5, choose “Layout” • Click on Site 1-5, choose “Functional view” Lets do that for every Site and draw big topology per each direction Lets understand what CTP calculated
  • 37.  In attach XLS based calculation of DC of Channel between Site-1 and Site-5 XLS based DC Calculation Site ID DCU-XXXX CD value Site ID DCU-XXXX CD value Site ID DCU-XXXXCD value Site ID DCU-XXXXCD value Site-1 none 0 Site-5-B none 0 Site-1 none 0 Site-5-B none 0 Fiber length 85 Fiber length 50 Fiber length 85 Fiber length 50 Fiber CD total 1402,5 Fiber CD total 825 Fiber CD total 1402,5 Fiber CD total 825 CD after fiber 1402,5 CD after fiber 825 CD after fiber 1402,5 CD after fiber 825 Site-2-B 1350 Site-4-A 450 Site-2-B 1350 Site-4-A 450 52,5 375 52,5 375 Fiber length 90 Fiber length 120 Calculation CD in CTP----------> Fiber length 90 Fiber length 120 Fiber CD total 1485 Fiber CD total 1980 Fiber CD total 1485 Fiber CD total 1980 CD after fiber 1537,5 CD after fiber 2355 CD after fiber 1537,5 CD after fiber 2355 Site-3-B 1350 Site-3-A 1350 Site-3-B 1350 Site-3-A 1350 187,5 550 187,5 550 Fiber length 120 455 5 This value calculates CTP Fiber length 120 450 5 Fiber CD total 1980 Fiber length 90 But have to be 455, CTP makes errorFiber CD total 1980 Fiber length 90 CD after fiber 2167,5 Fiber CD total 1485 It add aditional DCU-450 CD after fiber 2167,5 Fiber CD total 1485 Site-4-B 1350 CD after fiber 1940 Site-4-B 1350 CD after fiber 1490 450 Site-2-A 1350 450 Site-2-A 1150 550 590 340 This value calculates CTP 550 340 -182,5 Fiber length 85 But have to be 590, CTP makes error -182,5 Fiber length 85 Fiber length 50 Fiber CD total 1402,5 It add aditional DCU-450 Fiber length 50 Fiber CD total 1402,5 Fiber CD total 825 CD after fiber 1992,5 Fiber CD total 825 CD after fiber 1742,5 CD after fiber 642,5 Site-1-A 1350 CD after fiber 642,5 Site-1-A 1350 Site-5-B 550 642,5 392 This value calculates CTP Site-5-B 550 392,5 92,5 But have to be 642, CTP makes error 92,5 It add aditional DCU-450
  • 38. As result we can see some errors and make some conclutions:  CTP show in layout or doesn’t show correct DCU values on which based DC results in “Optical Results” report  Be care with CTP, use manual calculation to check, also use Forcing Manager to unlock and clear CD cache calculation.  Use “Forcing Manager” when you add new circuits in design  Do not make “Over-Compensation” and “Under-Compensation”, try to have CD of signal all the time in tolerance window. For example tolerance window for SFP+ Tunable from - 100 to 1100 ps/nm XLS based DC Calculation
  • 39. Force to clear CD calculation
  • 41. Polarization Mode Dispersion - a temporary difference between the polarization components of the same signal. Example A - optic cable has ideal dimensions of the X-axis and Y -> the same velocity of propagation. Example B - optic cable has different dimensions to the X-axis and Y -> propagation speed is different. Polarization Mode Dispersion (PMD)
  • 42. Causes of PMD: • The asymmetry of the core or the internal stress caused by the core during production • Internal stress caused by the core during the installation of optical cable Polarization Mode Dispersion (PMD)

Editor's Notes

  • #3: Сейчас я попрошу вас ответить на вопрос, что позволит мне понять аудиторию слушателей на сегодняшнем вэбексе.
  • #5: Сейчас мы обсудим все базовые положений, термины, единицы измерения после чего мы рассмотрим реализации оптических модулей Cisco.
  • #18: Сейчас мы обсудим все базовые положений, термины, единицы измерения после чего мы рассмотрим реализации оптических модулей Cisco.
  • #24: Сейчас мы обсудим все базовые положений, термины, единицы измерения после чего мы рассмотрим реализации оптических модулей Cisco.
  • #41: Сейчас мы обсудим все базовые положений, термины, единицы измерения после чего мы рассмотрим реализации оптических модулей Cisco.