Partial Discharge (PD) Tester
Diagrams of Discharge Analysis and
Analysis of Interference Causes
• In order to ensure the safety of electrical equipment, we often use
partial discharge tester to test electrical equipment.
• After the test is finished, the diagram of partial discharge tester will
display on the screen based on the measurement results, which is
used to show the electrical equipment and the surrounding
discharge. How to determine whether it is in a safe range according
to the diagram, which requires the analysis of the causes of each
diagram.
• Next, we will list some of the waveform diagram of partial discharge
tester, so that the test personnel can correctly judge the results of the
test, and record the safety performance of the electrical equipment.
• Diagram 1
This is capacitive discharge waveform, which can occur in
insulation or solid insulation bubbles. It occurs in the oil
immersed capacitor , insulation or insulation plastic filler in
paper. The discharge amplitude and pulse number
increase with the voltage .
• Diagram 2
The internal discharge of the interlayer medium may also occur
in the carbonized discharge of the insulating board and the
climbing of the branches.
• Diagram 3
The discharge of an insulating medium that is in contact with
each other and the discharge in the oil impregnated paper
capacitor.
• Diagram 4
In the same medium, different sizes of bubbles may also form
this kind of circular, mainly in the epoxy casting insulation.
Discharge volume changes with the voltage, such as the gap
between the capacitor layer.
• Diagram 5
In the insulation of an electric motor, the discharge in the mica
insulation of the motor, and the amount of discharge varies with
the time and pressure of the copy.
• Diagram 6
The discharge occurs between the metal and the dielectric
surface ,which may be an air gap between the metal and the
medium, or the surface conductivity is uneven.
• Diagram 7
The surface of the metal electrode is discharged, and the
exposed metal surface and the medium are discharged. The air
bubbles between the metal and the medium or the air bubbles
in the lift may contain impurities such as metal or carbon.
• Diagram 8
A small part of a metal foil or metallized sheet in a capacitor can
move under an electric field.
• Diagram 9
Discharge of poor contact or suspended metal , and the test
circuit is not reliable connection. The pulse amplitude of the
discharge pulse is equal to the positive and negative half cycle of
the discharge. The oscilloscope can observe the discharge pulse
pairs, figure (a),(b) this is because the oscilloscope effect caused
by visual error caused by light.
• Diagram 10
Contact noise discharge, poor contact between metal or
semiconductor shielding layer. At the same time, the discharge
distribution of the noise is small on the two sides of the test
voltage. As the voltage increases, the noise discharge coverage
increases, as shown in figure (a). Motor carbon brush to form a
spark discharge may occur in this waveform figure (b).
• Diagram 11
The metal electrode discharge concentration field, the
amplitude distribution in the isometric peak voltage on both
sides, with the corona and air discharge in the same voltage, the
discharge AC voltage exists in both positive and negative half
weeks, but 2.5 weeks amplitude asymmetry, discharge pulse
amplitude larger in the positive half cycle, then discharge at high
potential, and vice versa in low potential. Similar in oil and gas.
• Diagram 12
Suspended discharge in oil insulation and creepage, pulse
number, the critical voltage, discharge is not stable. Sometimes
for a few seconds, or stop a few seconds without discharge. The
discharge is with large amplitude, but like the external random
disturbance which need combined with waveform and judge the
disturbance caused by the discharge of fluorescent lamp.
• Diagram 13
Discharge by fluorescent lamp.
• Diagram 14
The interference of silicon controlled rectifier is symmetrically
distributed, and sometimes it is a single pulse.
• Diagram 15
In the case of asynchronous induction motor, the response of
the motor is independent of the test voltage, which may be
caused by the large asynchronous motor, and may be caused by
the large load of the transformer. However, when the generator
is turned on for the test, the difference between the generator
frequency and the power supply of the system instrument will
cause the discharge display waveform to rotate.
• Diagram 16
Industrial high frequency equipment interference, industrial
high frequency equipment such as ultrasonic generator,
induction heater etc.
• Diagram 17
The interference of amplitude
modulated sine wave signal is
mainly caused by the high power
high frequency power amplification
or the radio emission or radiation
interference of the oscillator and
the interference of the radio
station.
• Diagram 18
corona discharge
Corona discharge occurs at the metal tip or
the edge of the electric field. The corona
discharge occurs only in the half of the test
voltage, and symmetrically distributed on
both sides of the voltage peak, figure (a). As
the voltage increases, the number of pulses
(width) increases symmetrically, as shown in
figure (b). If the discharge tip electrode is in a
high potential, the corona discharge occurs at
the negative half of the test voltage. If the tip
electrode is in the ground potential, the
discharge pulse appears in the positive half
cycle. On one electrode, the initial corona
appeared in 1.5 weeks, but when the voltage
rises above the initial voltage of many, in the
other 1.5 weeks will also appear in large
amplitude, discharge less pulses, as shown in
figure (c).
PD-Test-System
Know more information ,
please visit our website [www.himalayal.com.cn]
Or e-mail me. [info@himalayal.com]

More Related Content

PPT
High voltage switchgear charged detection
PDF
Introduction to partial discharge
PPTX
Partial discharge testing
PPTX
Partial Discharge Test - Switchgear
PDF
Partial Discharge Techniques For Measuring Condition Of MV & HV Switchgear
PDF
Partial discharge switchgear ea tech
PPT
Streamer theory of breakdown
PPTX
Measurenments of DC Resistivity
High voltage switchgear charged detection
Introduction to partial discharge
Partial discharge testing
Partial Discharge Test - Switchgear
Partial Discharge Techniques For Measuring Condition Of MV & HV Switchgear
Partial discharge switchgear ea tech
Streamer theory of breakdown
Measurenments of DC Resistivity

What's hot (20)

PPTX
INTRINSIC OR IONIC BREAKDOWN MECHANISM OF SOLID DIELECTRICS|BREAKDOWN IN SOLI...
PDF
Chapter 01- High Voltage Engineering Introduction
PDF
EE2353 / High Voltage Engineering - Testing of Cables
PPTX
Behaviour of ZnO surge arrester in pollution
PPTX
BREAKDOWN MECHANISM OF GASEOUS , VACUUM, LIQUID & SOLID DIELECTRICS
PPTX
THERMOGRAPHY AND EDDY CURRENT TESTING (ET)
PPTX
Poster - Eddy Current Testing
PPTX
PROTECTION AGAINST OVER VOLTAGE AND GROUNDING Part 1
PPTX
Photoelectric transducers and its classification
DOCX
Surge arrester
PPT
Electrical discharge machining
PPT
Electrical discharge machining
PDF
Paul Stride - Electrical earth safety
PPTX
Piezoelectric transducer and its working
PDF
Geiger Muller counter
PPTX
Electro surgery in laparoscopy
PPT
Over voltages in power system
PPTX
Basic Cathodic Protection - CP Series - Eric Langelund
PDF
Corona Effect
PDF
Earthing electrode, Plate Earthing, Pipe earthing | Renown Earth
INTRINSIC OR IONIC BREAKDOWN MECHANISM OF SOLID DIELECTRICS|BREAKDOWN IN SOLI...
Chapter 01- High Voltage Engineering Introduction
EE2353 / High Voltage Engineering - Testing of Cables
Behaviour of ZnO surge arrester in pollution
BREAKDOWN MECHANISM OF GASEOUS , VACUUM, LIQUID & SOLID DIELECTRICS
THERMOGRAPHY AND EDDY CURRENT TESTING (ET)
Poster - Eddy Current Testing
PROTECTION AGAINST OVER VOLTAGE AND GROUNDING Part 1
Photoelectric transducers and its classification
Surge arrester
Electrical discharge machining
Electrical discharge machining
Paul Stride - Electrical earth safety
Piezoelectric transducer and its working
Geiger Muller counter
Electro surgery in laparoscopy
Over voltages in power system
Basic Cathodic Protection - CP Series - Eric Langelund
Corona Effect
Earthing electrode, Plate Earthing, Pipe earthing | Renown Earth
Ad

Similar to Diagram of Partial Discharge(PD) Tester (20)

PDF
03 partial discharge theory cutler-hammer
PPTX
Lecture 9 & 10.pptx high voltage electrical engineering
PPTX
Partial Discharge Detection Products by EA Technology
PDF
8 526-536
PDF
Chapter 09 - Measurement of Partial Discharge
PDF
High_Voltage_Engineering_2E.pdf
PDF
IEEE_2011_Conference
PDF
Nidec asi service partial discharge basic diagnostic
PDF
Electrical condition monitoring part 2
PDF
Fg34974984
PDF
Partial Discharges using Variable Frequency PRPDA Technique
PDF
PD_Presentation_1.pdf
PPT
IQ_Partial_Discharge_Presentation_complete.ppt
PPT
IQ_Partial_Discharge_Presentation.ppt
PPT
UNIT I - HVE.ppt
PDF
IEEE-Alberta_Partial-Discharge.pdf
PDF
ipec mtekpro joint venture technology for testing and measuring instruments
PDF
Fault identification in transformer winding
PDF
Fault identification in transformer winding
PDF
Lecture 2 edm wedm and medm
03 partial discharge theory cutler-hammer
Lecture 9 & 10.pptx high voltage electrical engineering
Partial Discharge Detection Products by EA Technology
8 526-536
Chapter 09 - Measurement of Partial Discharge
High_Voltage_Engineering_2E.pdf
IEEE_2011_Conference
Nidec asi service partial discharge basic diagnostic
Electrical condition monitoring part 2
Fg34974984
Partial Discharges using Variable Frequency PRPDA Technique
PD_Presentation_1.pdf
IQ_Partial_Discharge_Presentation_complete.ppt
IQ_Partial_Discharge_Presentation.ppt
UNIT I - HVE.ppt
IEEE-Alberta_Partial-Discharge.pdf
ipec mtekpro joint venture technology for testing and measuring instruments
Fault identification in transformer winding
Fault identification in transformer winding
Lecture 2 edm wedm and medm
Ad

Recently uploaded (20)

PDF
Spectral efficient network and resource selection model in 5G networks
PPTX
Big Data Technologies - Introduction.pptx
PDF
Accuracy of neural networks in brain wave diagnosis of schizophrenia
PPTX
Digital-Transformation-Roadmap-for-Companies.pptx
PDF
Encapsulation_ Review paper, used for researhc scholars
PDF
Assigned Numbers - 2025 - Bluetooth® Document
PDF
Profit Center Accounting in SAP S/4HANA, S4F28 Col11
PPTX
SOPHOS-XG Firewall Administrator PPT.pptx
PDF
Architecting across the Boundaries of two Complex Domains - Healthcare & Tech...
PDF
Unlocking AI with Model Context Protocol (MCP)
PDF
Machine learning based COVID-19 study performance prediction
PDF
7 ChatGPT Prompts to Help You Define Your Ideal Customer Profile.pdf
PPTX
20250228 LYD VKU AI Blended-Learning.pptx
PDF
gpt5_lecture_notes_comprehensive_20250812015547.pdf
PDF
NewMind AI Weekly Chronicles - August'25-Week II
PPTX
MYSQL Presentation for SQL database connectivity
PDF
Approach and Philosophy of On baking technology
PPTX
Programs and apps: productivity, graphics, security and other tools
PDF
cuic standard and advanced reporting.pdf
PDF
The Rise and Fall of 3GPP – Time for a Sabbatical?
Spectral efficient network and resource selection model in 5G networks
Big Data Technologies - Introduction.pptx
Accuracy of neural networks in brain wave diagnosis of schizophrenia
Digital-Transformation-Roadmap-for-Companies.pptx
Encapsulation_ Review paper, used for researhc scholars
Assigned Numbers - 2025 - Bluetooth® Document
Profit Center Accounting in SAP S/4HANA, S4F28 Col11
SOPHOS-XG Firewall Administrator PPT.pptx
Architecting across the Boundaries of two Complex Domains - Healthcare & Tech...
Unlocking AI with Model Context Protocol (MCP)
Machine learning based COVID-19 study performance prediction
7 ChatGPT Prompts to Help You Define Your Ideal Customer Profile.pdf
20250228 LYD VKU AI Blended-Learning.pptx
gpt5_lecture_notes_comprehensive_20250812015547.pdf
NewMind AI Weekly Chronicles - August'25-Week II
MYSQL Presentation for SQL database connectivity
Approach and Philosophy of On baking technology
Programs and apps: productivity, graphics, security and other tools
cuic standard and advanced reporting.pdf
The Rise and Fall of 3GPP – Time for a Sabbatical?

Diagram of Partial Discharge(PD) Tester

  • 3. Diagrams of Discharge Analysis and Analysis of Interference Causes • In order to ensure the safety of electrical equipment, we often use partial discharge tester to test electrical equipment. • After the test is finished, the diagram of partial discharge tester will display on the screen based on the measurement results, which is used to show the electrical equipment and the surrounding discharge. How to determine whether it is in a safe range according to the diagram, which requires the analysis of the causes of each diagram.
  • 4. • Next, we will list some of the waveform diagram of partial discharge tester, so that the test personnel can correctly judge the results of the test, and record the safety performance of the electrical equipment.
  • 5. • Diagram 1 This is capacitive discharge waveform, which can occur in insulation or solid insulation bubbles. It occurs in the oil immersed capacitor , insulation or insulation plastic filler in paper. The discharge amplitude and pulse number increase with the voltage .
  • 6. • Diagram 2 The internal discharge of the interlayer medium may also occur in the carbonized discharge of the insulating board and the climbing of the branches.
  • 7. • Diagram 3 The discharge of an insulating medium that is in contact with each other and the discharge in the oil impregnated paper capacitor.
  • 8. • Diagram 4 In the same medium, different sizes of bubbles may also form this kind of circular, mainly in the epoxy casting insulation. Discharge volume changes with the voltage, such as the gap between the capacitor layer.
  • 9. • Diagram 5 In the insulation of an electric motor, the discharge in the mica insulation of the motor, and the amount of discharge varies with the time and pressure of the copy.
  • 10. • Diagram 6 The discharge occurs between the metal and the dielectric surface ,which may be an air gap between the metal and the medium, or the surface conductivity is uneven.
  • 11. • Diagram 7 The surface of the metal electrode is discharged, and the exposed metal surface and the medium are discharged. The air bubbles between the metal and the medium or the air bubbles in the lift may contain impurities such as metal or carbon.
  • 12. • Diagram 8 A small part of a metal foil or metallized sheet in a capacitor can move under an electric field.
  • 13. • Diagram 9 Discharge of poor contact or suspended metal , and the test circuit is not reliable connection. The pulse amplitude of the discharge pulse is equal to the positive and negative half cycle of the discharge. The oscilloscope can observe the discharge pulse pairs, figure (a),(b) this is because the oscilloscope effect caused by visual error caused by light.
  • 14. • Diagram 10 Contact noise discharge, poor contact between metal or semiconductor shielding layer. At the same time, the discharge distribution of the noise is small on the two sides of the test voltage. As the voltage increases, the noise discharge coverage increases, as shown in figure (a). Motor carbon brush to form a spark discharge may occur in this waveform figure (b).
  • 15. • Diagram 11 The metal electrode discharge concentration field, the amplitude distribution in the isometric peak voltage on both sides, with the corona and air discharge in the same voltage, the discharge AC voltage exists in both positive and negative half weeks, but 2.5 weeks amplitude asymmetry, discharge pulse amplitude larger in the positive half cycle, then discharge at high potential, and vice versa in low potential. Similar in oil and gas.
  • 16. • Diagram 12 Suspended discharge in oil insulation and creepage, pulse number, the critical voltage, discharge is not stable. Sometimes for a few seconds, or stop a few seconds without discharge. The discharge is with large amplitude, but like the external random disturbance which need combined with waveform and judge the disturbance caused by the discharge of fluorescent lamp.
  • 17. • Diagram 13 Discharge by fluorescent lamp.
  • 18. • Diagram 14 The interference of silicon controlled rectifier is symmetrically distributed, and sometimes it is a single pulse.
  • 19. • Diagram 15 In the case of asynchronous induction motor, the response of the motor is independent of the test voltage, which may be caused by the large asynchronous motor, and may be caused by the large load of the transformer. However, when the generator is turned on for the test, the difference between the generator frequency and the power supply of the system instrument will cause the discharge display waveform to rotate.
  • 20. • Diagram 16 Industrial high frequency equipment interference, industrial high frequency equipment such as ultrasonic generator, induction heater etc.
  • 21. • Diagram 17 The interference of amplitude modulated sine wave signal is mainly caused by the high power high frequency power amplification or the radio emission or radiation interference of the oscillator and the interference of the radio station.
  • 22. • Diagram 18 corona discharge Corona discharge occurs at the metal tip or the edge of the electric field. The corona discharge occurs only in the half of the test voltage, and symmetrically distributed on both sides of the voltage peak, figure (a). As the voltage increases, the number of pulses (width) increases symmetrically, as shown in figure (b). If the discharge tip electrode is in a high potential, the corona discharge occurs at the negative half of the test voltage. If the tip electrode is in the ground potential, the discharge pulse appears in the positive half cycle. On one electrode, the initial corona appeared in 1.5 weeks, but when the voltage rises above the initial voltage of many, in the other 1.5 weeks will also appear in large amplitude, discharge less pulses, as shown in figure (c).
  • 24. Know more information , please visit our website [www.himalayal.com.cn] Or e-mail me. [info@himalayal.com]