Installation Issues for
Converged AV/IT Systems
Andre LeJeune, CTS
© 2015 InfoComm International®
About InfoComm Academy®
• Extensive offering of audiovisual
courses designed by experts and
taught by AV professionals
• Delivered
2
© 2015 InfoComm International®
www.infocomm.org
© 2015 InfoComm International®
Working with IT Professionals
• Specific means of documentation
• International standards (EIA, TIA, ISO,
ITC, etc.)
• Industry standard construction methods:
– BICSI
• Conservative new technology adoption
• Content is mostly information; desktops
• Only one or two cabling types
3
© 2015 InfoComm International®
Working with AV Professionals
• Non-standard documentation
• Lack of standards
• Proprietary techniques
• Constant new technology adoption
• Content is multimedia, large rooms
• Many cabling types
© 2015 InfoComm International®
What IT People Care About
• Smooth operations
– no downtime
• Unified “build” of
computers
• Security of network
• Scheduled backups
• Help Desk
operations
4
© 2015 InfoComm International®
Audiovisual and Network Signals
• Audio: microphone, line, loudspeaker
• Video: composite NTSC, PAL, SECAM
• TV: Radio Frequency (RF)
• HDTV: DVI, HDMI, IEEE 1394 (Firewire)
• Broadcast: SDI, AES/EBU
• Computer Data: RGBHV (VGA)
• Control: Closures, TTL, serial, infrared (IR)
• Network: Ethernet
• Combinations: Proprietary
© 2015 InfoComm International®
Traditional Audiovisual/Control Block Diagram
6
5
© 2015 InfoComm International®
What is AV/IT Convergence and Why?
• Began with multi-room control
• Existing IT infrastructure
• Mature digitization technologies
• Videoconferencing
• Inter-building audiovisual transport
• Enterprise management
• Consolidation of resources
© 2015 InfoComm International®
“Hybrid” Audiovisual/Control Block Diagram
using Structured Cabling
8
8
88
8
8
8 8
8 8
8
8
6
6
© 2015 InfoComm International®
Where Are We Now with AV/IT?
• Traditional audiovisual technology is very
mature, very robust – but limited
• “Hybrid” AV/IT systems use structured
cabling but traditional AV signals
• Videoconferencing, streaming media are
almost all IT now
• High bandwidth networks
• Bottlenecks
© 2015 InfoComm International®
“Converged” AV/IT Block Diagram
7
© 2015 InfoComm International®
AV/IT Project Cooperation and Coordination
• Unusual locations for information outlets
• Floor and wallboxes, furniture connectivity
• Wireless technology policies
• Network segregation
• IP addresses
• Use of structured cabling
• Firewalls
© 2015 InfoComm International®
The IT Domains
• IT infrastructure is highly
organized in standard
formats:
– Demarcation room
– Data center
– Backbone cabling
– Information closets
– Horizontal cabling
– Information outlets
8
© 2015 InfoComm International®
The IT Domains: The Demarcation Room
• Secure entry point for voice/data
services to building
• Sometimes redundant services
• Access for service providers:
– Voice/data lines (T1, E1, etc.)
– Copper trunks
– ISP (Internet Service Provider)
– Cable television
© 2015 InfoComm International®
The IT Domains: The Data Center
• Secure entry
• Environmentally controlled
• Organized: equipment racks
• Uninterruptible power
• Servers, routers, switches
• May or may not have operations stations
9
© 2015 InfoComm International®
The IT Domains: Backbone Cabling
• Interconnections between
telecommunications rooms, equipment
rooms, and entrance facilities
• Cables
• intermediate and main cross-connects
• Patch cords or jumpers used for cross-
connections
• Extensions between buildings in a campus
environment.
© 2015 InfoComm International®
The IT Domains: The IDF
• Data Closets (IDF)
• Located throughout building
• Patch points
• Fiber/copper
• Switches, routers
• Sometimes “video:” CATV, SAT
10
© 2015 InfoComm International®
IDF Installation Example
© 2015 InfoComm International®
The IT Domains: The Information Outlet
• Data jacks
• Usually copper cabling, RJ-45 (8-pin
modular) connectors
• May be Fiber-To-The-Desktop
• Mulitple jacks in each outlet, according
to the enterprise’s standard
• “Flood” the facility
11
© 2015 InfoComm International®
Following Cabling Guidelines
• IT professionals
prefer to see all
cabling comply to
their facility
standard
• Use building
cabling or run new
cabling?
© 2015 InfoComm International®
Infrastructure Devices: Table Boxes
• Doors/pockets
• Pop-up
• Flip-up
• Custom
• Audiovisual
• Power
• Information
outlet
12
© 2015 InfoComm International®
Infrastructure Devices: Structured Cabling
• Information Outlets: RJ-45
• Category 5, 5e, 6
• Fiber optic cabling
• IDF (Intermediate Data
Frame)
• MDF (Main Data Frame)
• BICSI, RCDD (Building
Industry Consulting
Service International Inc.)
© 2015 InfoComm International®
Infrastructure Devices:
Electrical Pathways
• Tray
• Conduit
• Ladder rack
• Trough
• “Wiremold”
• Bridal rings
• J-Hooks
13
© 2015 InfoComm International®
Example: Hybrid AV / IT
Courtroom Audio/Audiovisual System
© 2015 InfoComm International®
CAT What?
• “Category - #”
cable and
performance
standards
correspond to
bandwidth-
carrying
capabilities,
attenuation,
and Near-End
Crosstalk
(NEXT) of
system
Standard
Freq.
Range
(MHz)
Atten.
(dB)
NEXT
(dB)
CAT-5 1-100
100 Kbps
24 27.1
CAT-5E 1-100
1 Gbps
24 30.1
CAT-6 1-250
1 Gbps
21.7 39.3
CAT-7* 1-600
1-10 Gbps
20.8 62.1
*CAT-7 is a proposed standard: new connector
14
© 2015 InfoComm International®
IT Terminations
• Punch Blocks
• RJ-45 (8-pin modular) Connectors
• Fiber Optics
– Telephone Type
– Data Type
We will do the first two…..
© 2015 InfoComm International®
IT Patch Bays:
• Every line must run through
a patch bay
• Usually equipment racks in
an IDF (data closet) and
MDF (data center) have a
standard number of patch
bays and patch points
• No “normalled” connections
15
© 2015 InfoComm International®
UTP Wiremap
• Two main
termination
standards
– T568A
– T568B
• Verify which
standard your
client is using
for the
enterprise!
Gn/wht, Gn, Orng/wht, Blue, Blue/wht, Orng, Brn/wht, Brn Orng/wht, Orng, Grn/wht, Blue, Blue/wht, Grn, Brn/wht, Brn
© 2015 InfoComm International®
UTP Pinout
• Straight-through
• Crossover
16
© 2015 InfoComm International®
Testing
– Network Cabling Infrastructure
– Network Performance
© 2015 InfoComm International®
Why Infrastructure Testing?
– Clients require a “certified” cabling system
– Robust infrastructure and network
– Network may have problems with
streaming media
– Network administrator
17
© 2015 InfoComm International®
4 Levels of Network Testing
• Wiremap (correct “pin-out”)
– Basic Level: Cables pass signals
• Cable Verification
– Cabling conforms to basic capability standards
• Network Certification
– Network cabling conforms to bandwidth standards
– Ready to turn on active components
• Network Operation
– Identification of network components
– IP Addresses
© 2015 InfoComm International®
Network Certification
• Cabling verification PLUS:
• Performance and Speed Verification:
– Signal speed carrying specifications to 1 gigabit
– Interconnect specifications
– Quality of the signal
– Real-time testing of cable capability
– Measurement of signal quality
18
© 2015 InfoComm International®
Installation Issues
• CAT# cable maximum pull force 25 lbs.
• Do not crush cable in any way:
– Velcro cable ties
• Minimum bend radius 1” (25 mm)
• Conform to conduit/material codes
• Conform to building standards
• Alien crosstalk (AXT)
• Proximity to power sources
© 2015 InfoComm International®
Bandwidth and the Network
• Bandwidth is a range of frequencies that
passes through a system
• “Speed” of the network
• “Size of the pipe”
19
© 2015 InfoComm International®
Performance PASS/FAIL
• Testers are
programmed with
performance
parameters and
indicate PASS or
FAIL
• Tester must be told
what type of cable is
being used
© 2015 InfoComm International®
20
© 2015 InfoComm International®
www.infocomm.org
+1 703.273.7200

More Related Content

PDF
Connectors, Cables, Terminations and Rack Building
PDF
Designing Commercial Systems for Maximum Performance and Profit
PPTX
IP Signal Distribution
PDF
Kordik fundamental guidtoindustrialnetworking -v_imp
PDF
Presentatie Alcom - Meetup
PPTX
Video-over-IP for AV
PDF
Lecture1
PPTX
Assessing Network Readiness
Connectors, Cables, Terminations and Rack Building
Designing Commercial Systems for Maximum Performance and Profit
IP Signal Distribution
Kordik fundamental guidtoindustrialnetworking -v_imp
Presentatie Alcom - Meetup
Video-over-IP for AV
Lecture1
Assessing Network Readiness

What's hot (20)

PDF
Advanced radio over IP
PDF
intro-5169
PDF
Airheads scottsdale 2010 broadcast quality video over 11n
PDF
Uni fi switch
PDF
M2M communication and the IP revolution in radio. A marriage made in the clou...
PPTX
SVSi_Networked AV
PDF
Air heads rio 2010 controlling the air
PDF
Advanced Radio over IP
PDF
4 healthcare forum deploying vocera on aruba wlan_kevin huey
PPTX
Raritan AV-over-IP (RAV-IP) Distribution System
PPT
Keyboard, Video And Mouse (KVM) Switch Solution
PPTX
PDF
Air heads rio 2010 outdoor wla-ns
PPT
Web technology
PPTX
Deploying Microsoft Lync over Wi-Fi #AirheadsConf Italy
PPTX
Hostile Environments: Wireless LAN Design for Warehouse WLPC
PDF
Future of voip- karan singh cypher
PDF
2012 ah vegas rf fundamentals
DOC
Jishan resume
PDF
ETE405-lec4.pdf
Advanced radio over IP
intro-5169
Airheads scottsdale 2010 broadcast quality video over 11n
Uni fi switch
M2M communication and the IP revolution in radio. A marriage made in the clou...
SVSi_Networked AV
Air heads rio 2010 controlling the air
Advanced Radio over IP
4 healthcare forum deploying vocera on aruba wlan_kevin huey
Raritan AV-over-IP (RAV-IP) Distribution System
Keyboard, Video And Mouse (KVM) Switch Solution
Air heads rio 2010 outdoor wla-ns
Web technology
Deploying Microsoft Lync over Wi-Fi #AirheadsConf Italy
Hostile Environments: Wireless LAN Design for Warehouse WLPC
Future of voip- karan singh cypher
2012 ah vegas rf fundamentals
Jishan resume
ETE405-lec4.pdf
Ad

Similar to Installation Issues for Converged AV/IT Systems (20)

PPTX
Industrial Ethernet, Part 1: Technologies
PPT
goldman5gdoevrosps8evosyurobaibd80wkq8.ppt
PPTX
av-over-ip-130819080827-phpapp02.pptx
PPTX
ppt ch15
PPT
Network Technology Presentation Bvh V01
PPTX
Internet of Things - structured approach to the physical plant network - Rock...
PPT
netessentials6e-ch4-130812150022-phpapp02.ppt
PPTX
Understanding Different Cabling Technologies.pptx
PPT
Peripheral component trends structured cabling systems - Propducts with Mar...
PPT
BVH Network Technology Presentation
PPT
Chapter10
PDF
01 - networking basics notes
PPT
Net essentials6e ch4
PDF
Intern
PDF
Ethernet The Definitive Guide 2nd Edition Charles E. Spurgeon 2024 Scribd Dow...
PDF
Ethernet The Definitive Guide 2nd Edition Charles E. Spurgeon
PDF
Industrial Automation Infrastructure
PDF
Making Industrial Ethernet Standards Work For You
PPT
ISDN VSAT Ethernet and other recent technologies in networking
PPT
Structured cabling
Industrial Ethernet, Part 1: Technologies
goldman5gdoevrosps8evosyurobaibd80wkq8.ppt
av-over-ip-130819080827-phpapp02.pptx
ppt ch15
Network Technology Presentation Bvh V01
Internet of Things - structured approach to the physical plant network - Rock...
netessentials6e-ch4-130812150022-phpapp02.ppt
Understanding Different Cabling Technologies.pptx
Peripheral component trends structured cabling systems - Propducts with Mar...
BVH Network Technology Presentation
Chapter10
01 - networking basics notes
Net essentials6e ch4
Intern
Ethernet The Definitive Guide 2nd Edition Charles E. Spurgeon 2024 Scribd Dow...
Ethernet The Definitive Guide 2nd Edition Charles E. Spurgeon
Industrial Automation Infrastructure
Making Industrial Ethernet Standards Work For You
ISDN VSAT Ethernet and other recent technologies in networking
Structured cabling
Ad

More from rAVe [PUBS] (20)

PDF
Kayye's Krystal Ball - Updated 2019
PDF
Installation Issues for Converged AV/IT Systems
PDF
Universal Serial Bus (USB) Deep Dive Technology Exploration for AV Design and...
PDF
Avoiding Pitfalls in Digital Signage Installations and Content
PDF
AV in an IT World
PDF
An Unbiased Explanation of AV-over-IP - Updated March 2019
PDF
Introduction to Windows Collaboration Displays
PDF
Digital Signage Content Strategies for Savvy Integrators
PDF
Kayye’s Krystal Ball 2018
PDF
UPDATED: OLED, The Curve of the Future
PDF
An Unbiased Explanation of AV-over-IP
PDF
Top 10 (+2) Things Gary Kayye Saw at InfoComm 2018
PDF
The Future of Digital Signage in Smart Connected Cities
PDF
An Introduction and Comparison of Dante, AVB and CobraNet Methodologies
PDF
The Internet of Things Conference at E4
PDF
The Future of Meeting Rooms and Classrooms is the 4K Digital Canvas
PDF
OLED Curve of the Future
PDF
Dante Audio Networking Fundamentals
PPTX
Understanding and Specifying Outdoor LFD with Samsung
PPTX
Projector Training - Solid State Light Source Technology
Kayye's Krystal Ball - Updated 2019
Installation Issues for Converged AV/IT Systems
Universal Serial Bus (USB) Deep Dive Technology Exploration for AV Design and...
Avoiding Pitfalls in Digital Signage Installations and Content
AV in an IT World
An Unbiased Explanation of AV-over-IP - Updated March 2019
Introduction to Windows Collaboration Displays
Digital Signage Content Strategies for Savvy Integrators
Kayye’s Krystal Ball 2018
UPDATED: OLED, The Curve of the Future
An Unbiased Explanation of AV-over-IP
Top 10 (+2) Things Gary Kayye Saw at InfoComm 2018
The Future of Digital Signage in Smart Connected Cities
An Introduction and Comparison of Dante, AVB and CobraNet Methodologies
The Internet of Things Conference at E4
The Future of Meeting Rooms and Classrooms is the 4K Digital Canvas
OLED Curve of the Future
Dante Audio Networking Fundamentals
Understanding and Specifying Outdoor LFD with Samsung
Projector Training - Solid State Light Source Technology

Recently uploaded (20)

PDF
Empathic Computing: Creating Shared Understanding
PDF
Blue Purple Modern Animated Computer Science Presentation.pdf.pdf
PPTX
Big Data Technologies - Introduction.pptx
PPTX
Programs and apps: productivity, graphics, security and other tools
PDF
Reach Out and Touch Someone: Haptics and Empathic Computing
PDF
Mobile App Security Testing_ A Comprehensive Guide.pdf
PDF
TokAI - TikTok AI Agent : The First AI Application That Analyzes 10,000+ Vira...
PPT
“AI and Expert System Decision Support & Business Intelligence Systems”
PDF
Approach and Philosophy of On baking technology
PDF
Diabetes mellitus diagnosis method based random forest with bat algorithm
PDF
7 ChatGPT Prompts to Help You Define Your Ideal Customer Profile.pdf
PPT
Teaching material agriculture food technology
PDF
Advanced methodologies resolving dimensionality complications for autism neur...
PPTX
A Presentation on Artificial Intelligence
PDF
cuic standard and advanced reporting.pdf
PDF
Build a system with the filesystem maintained by OSTree @ COSCUP 2025
PDF
Video forgery: An extensive analysis of inter-and intra-frame manipulation al...
PDF
Optimiser vos workloads AI/ML sur Amazon EC2 et AWS Graviton
PDF
Encapsulation_ Review paper, used for researhc scholars
PDF
MIND Revenue Release Quarter 2 2025 Press Release
Empathic Computing: Creating Shared Understanding
Blue Purple Modern Animated Computer Science Presentation.pdf.pdf
Big Data Technologies - Introduction.pptx
Programs and apps: productivity, graphics, security and other tools
Reach Out and Touch Someone: Haptics and Empathic Computing
Mobile App Security Testing_ A Comprehensive Guide.pdf
TokAI - TikTok AI Agent : The First AI Application That Analyzes 10,000+ Vira...
“AI and Expert System Decision Support & Business Intelligence Systems”
Approach and Philosophy of On baking technology
Diabetes mellitus diagnosis method based random forest with bat algorithm
7 ChatGPT Prompts to Help You Define Your Ideal Customer Profile.pdf
Teaching material agriculture food technology
Advanced methodologies resolving dimensionality complications for autism neur...
A Presentation on Artificial Intelligence
cuic standard and advanced reporting.pdf
Build a system with the filesystem maintained by OSTree @ COSCUP 2025
Video forgery: An extensive analysis of inter-and intra-frame manipulation al...
Optimiser vos workloads AI/ML sur Amazon EC2 et AWS Graviton
Encapsulation_ Review paper, used for researhc scholars
MIND Revenue Release Quarter 2 2025 Press Release

Installation Issues for Converged AV/IT Systems

  • 1. 1 © 2015 InfoComm International® Installation Issues for Converged AV/IT Systems Andre LeJeune, CTS © 2015 InfoComm International® About InfoComm Academy® • Extensive offering of audiovisual courses designed by experts and taught by AV professionals • Delivered
  • 2. 2 © 2015 InfoComm International® www.infocomm.org © 2015 InfoComm International® Working with IT Professionals • Specific means of documentation • International standards (EIA, TIA, ISO, ITC, etc.) • Industry standard construction methods: – BICSI • Conservative new technology adoption • Content is mostly information; desktops • Only one or two cabling types
  • 3. 3 © 2015 InfoComm International® Working with AV Professionals • Non-standard documentation • Lack of standards • Proprietary techniques • Constant new technology adoption • Content is multimedia, large rooms • Many cabling types © 2015 InfoComm International® What IT People Care About • Smooth operations – no downtime • Unified “build” of computers • Security of network • Scheduled backups • Help Desk operations
  • 4. 4 © 2015 InfoComm International® Audiovisual and Network Signals • Audio: microphone, line, loudspeaker • Video: composite NTSC, PAL, SECAM • TV: Radio Frequency (RF) • HDTV: DVI, HDMI, IEEE 1394 (Firewire) • Broadcast: SDI, AES/EBU • Computer Data: RGBHV (VGA) • Control: Closures, TTL, serial, infrared (IR) • Network: Ethernet • Combinations: Proprietary © 2015 InfoComm International® Traditional Audiovisual/Control Block Diagram 6
  • 5. 5 © 2015 InfoComm International® What is AV/IT Convergence and Why? • Began with multi-room control • Existing IT infrastructure • Mature digitization technologies • Videoconferencing • Inter-building audiovisual transport • Enterprise management • Consolidation of resources © 2015 InfoComm International® “Hybrid” Audiovisual/Control Block Diagram using Structured Cabling 8 8 88 8 8 8 8 8 8 8 8 6
  • 6. 6 © 2015 InfoComm International® Where Are We Now with AV/IT? • Traditional audiovisual technology is very mature, very robust – but limited • “Hybrid” AV/IT systems use structured cabling but traditional AV signals • Videoconferencing, streaming media are almost all IT now • High bandwidth networks • Bottlenecks © 2015 InfoComm International® “Converged” AV/IT Block Diagram
  • 7. 7 © 2015 InfoComm International® AV/IT Project Cooperation and Coordination • Unusual locations for information outlets • Floor and wallboxes, furniture connectivity • Wireless technology policies • Network segregation • IP addresses • Use of structured cabling • Firewalls © 2015 InfoComm International® The IT Domains • IT infrastructure is highly organized in standard formats: – Demarcation room – Data center – Backbone cabling – Information closets – Horizontal cabling – Information outlets
  • 8. 8 © 2015 InfoComm International® The IT Domains: The Demarcation Room • Secure entry point for voice/data services to building • Sometimes redundant services • Access for service providers: – Voice/data lines (T1, E1, etc.) – Copper trunks – ISP (Internet Service Provider) – Cable television © 2015 InfoComm International® The IT Domains: The Data Center • Secure entry • Environmentally controlled • Organized: equipment racks • Uninterruptible power • Servers, routers, switches • May or may not have operations stations
  • 9. 9 © 2015 InfoComm International® The IT Domains: Backbone Cabling • Interconnections between telecommunications rooms, equipment rooms, and entrance facilities • Cables • intermediate and main cross-connects • Patch cords or jumpers used for cross- connections • Extensions between buildings in a campus environment. © 2015 InfoComm International® The IT Domains: The IDF • Data Closets (IDF) • Located throughout building • Patch points • Fiber/copper • Switches, routers • Sometimes “video:” CATV, SAT
  • 10. 10 © 2015 InfoComm International® IDF Installation Example © 2015 InfoComm International® The IT Domains: The Information Outlet • Data jacks • Usually copper cabling, RJ-45 (8-pin modular) connectors • May be Fiber-To-The-Desktop • Mulitple jacks in each outlet, according to the enterprise’s standard • “Flood” the facility
  • 11. 11 © 2015 InfoComm International® Following Cabling Guidelines • IT professionals prefer to see all cabling comply to their facility standard • Use building cabling or run new cabling? © 2015 InfoComm International® Infrastructure Devices: Table Boxes • Doors/pockets • Pop-up • Flip-up • Custom • Audiovisual • Power • Information outlet
  • 12. 12 © 2015 InfoComm International® Infrastructure Devices: Structured Cabling • Information Outlets: RJ-45 • Category 5, 5e, 6 • Fiber optic cabling • IDF (Intermediate Data Frame) • MDF (Main Data Frame) • BICSI, RCDD (Building Industry Consulting Service International Inc.) © 2015 InfoComm International® Infrastructure Devices: Electrical Pathways • Tray • Conduit • Ladder rack • Trough • “Wiremold” • Bridal rings • J-Hooks
  • 13. 13 © 2015 InfoComm International® Example: Hybrid AV / IT Courtroom Audio/Audiovisual System © 2015 InfoComm International® CAT What? • “Category - #” cable and performance standards correspond to bandwidth- carrying capabilities, attenuation, and Near-End Crosstalk (NEXT) of system Standard Freq. Range (MHz) Atten. (dB) NEXT (dB) CAT-5 1-100 100 Kbps 24 27.1 CAT-5E 1-100 1 Gbps 24 30.1 CAT-6 1-250 1 Gbps 21.7 39.3 CAT-7* 1-600 1-10 Gbps 20.8 62.1 *CAT-7 is a proposed standard: new connector
  • 14. 14 © 2015 InfoComm International® IT Terminations • Punch Blocks • RJ-45 (8-pin modular) Connectors • Fiber Optics – Telephone Type – Data Type We will do the first two….. © 2015 InfoComm International® IT Patch Bays: • Every line must run through a patch bay • Usually equipment racks in an IDF (data closet) and MDF (data center) have a standard number of patch bays and patch points • No “normalled” connections
  • 15. 15 © 2015 InfoComm International® UTP Wiremap • Two main termination standards – T568A – T568B • Verify which standard your client is using for the enterprise! Gn/wht, Gn, Orng/wht, Blue, Blue/wht, Orng, Brn/wht, Brn Orng/wht, Orng, Grn/wht, Blue, Blue/wht, Grn, Brn/wht, Brn © 2015 InfoComm International® UTP Pinout • Straight-through • Crossover
  • 16. 16 © 2015 InfoComm International® Testing – Network Cabling Infrastructure – Network Performance © 2015 InfoComm International® Why Infrastructure Testing? – Clients require a “certified” cabling system – Robust infrastructure and network – Network may have problems with streaming media – Network administrator
  • 17. 17 © 2015 InfoComm International® 4 Levels of Network Testing • Wiremap (correct “pin-out”) – Basic Level: Cables pass signals • Cable Verification – Cabling conforms to basic capability standards • Network Certification – Network cabling conforms to bandwidth standards – Ready to turn on active components • Network Operation – Identification of network components – IP Addresses © 2015 InfoComm International® Network Certification • Cabling verification PLUS: • Performance and Speed Verification: – Signal speed carrying specifications to 1 gigabit – Interconnect specifications – Quality of the signal – Real-time testing of cable capability – Measurement of signal quality
  • 18. 18 © 2015 InfoComm International® Installation Issues • CAT# cable maximum pull force 25 lbs. • Do not crush cable in any way: – Velcro cable ties • Minimum bend radius 1” (25 mm) • Conform to conduit/material codes • Conform to building standards • Alien crosstalk (AXT) • Proximity to power sources © 2015 InfoComm International® Bandwidth and the Network • Bandwidth is a range of frequencies that passes through a system • “Speed” of the network • “Size of the pipe”
  • 19. 19 © 2015 InfoComm International® Performance PASS/FAIL • Testers are programmed with performance parameters and indicate PASS or FAIL • Tester must be told what type of cable is being used © 2015 InfoComm International®
  • 20. 20 © 2015 InfoComm International® www.infocomm.org +1 703.273.7200