IJSRD - International Journal for Scientific Research & Development| Vol. 3, Issue 10, 2015 | ISSN (online): 2321-0613
All rights reserved by www.ijsrd.com 754
Study on Effect of Wind Load and Earthquake Load on Multistorey RC
Framed Buildings
Mohammed Aejaz Ahmed1
Prof. Dr.Shreenivas Reddy Shahpur2
Prof. Brij Bhushan S3
Prof. Rohan Gurav4
Prof. Shaik Abdull5
1
M. Tech Student 2
H.O. D 3,4
Assistant Professor
1,2,3,4
Department of Construction Technology 5
Department of Civil Engineering
1,2,3,4
VTU Regional Center Gulbarga, Karnataka, India 5
KBN college of engineering Gulbarga,
Karnataka
Abstract— Now a day the increase in the construction of tall
buildings, residential and commercial sector, and the new
trend are towards taller and slender structures. Though the
effect of wind and earthquake, forces becoming important
for every structural designer to know. Every engineer is
facing with the problem of providing stability, strength for
loads like lateral loads. That’s the reason wind as well as
earthquake loading have become the influential factors in
tall buildings. Loads that are lateral loads play important
role for drift. The drift must be taken into consideration for
tall structure. The above mentioned are some of the key
issues which affect the behavior of structure and economy of
the building. This thesis focuses the effects of lateral loads
on medium and tall buildings the storey forces,
displacements, storey shear, story drift every part of are
analyzed on every level of height on the building, Indian
codal provision gives us the basic wind speed at 10m height
for some important cities/towns. However it does not
provide for all the cities in India. In the following work
attempt is made to find the effect of lateral loads i.e. wind
load and earth quake loads for various models having shear
walls and without shear wall. For the study a symmetrical
building plan is used with 16 storeys and 31 storeys are
analyzed and designed by using structure analysis software
tool ETABS-2013. The study also includes the
determination of base shear, displacement, storey drift,
storey forces and the results are compared with them. These
parameters have also considers the effect of shear wall. In
order to design a structure to resist wind and earthquake
loads, the forces on the structure must be specified.
Key words: Steel Slag, Waste Limestone Aggregates, M20
grade concrete, Partial replacement etc
I. INTRODUCTION
A. General
Rapid increase in the construction of tall buildings,
commercial as well as residential building leads towards the
construction of high rise buildings. Lateral loads similar to
wind loads and earthquake loads are thus getting
importance. Even though all the designers are facing the
problems of getting possible strength and stability not in
favour of lateral loads, one of the common used wall which
is used for lateral load resisting in tall buildings is the shear
wall. Vertical winds are known by the same name whereas
the wind loads are known as horizontal winds.
Anemometers measure the speed of wind, they are installed
at the height of approximately 10 to 30 meters at
meteorological observatories on the top of the ground.
Thunderstorms, dust storms, cyclonic storms are powerful
winds. In our Study we are examining ground plus 15 and
ground plus 30 storey building and analyzing design under
effect of earthquake and wind by the use of ETABS. Six
different models are being analyzed, and thus proving that
the shear wall models resist earthquake and wind loads.
Then the results are compared and analyzed to achieve the
most suitable resisting system and economic structure
against the lateral forces. The main factor which
differentiates the high, medium and low rise buildings is the
effect of lateral load because of the wind. For buildings of
up to about 10 storied and of typical properties and the
design is rarely affected by the wind loads. Above this
height, however, the increase in size of the structural
members, and the possible rearrangement of the structure to
account for wind load, incurs a cost premium that increases
progressively with height.
II. LITERATURE REVIEW
Anshuman. S, Dipendu Bhunia and Bhavin Ramjiyani ,
Civil and Structural Engineering, International Journal of
Vol 2, (2011) There study shows in multi storey building the
solution of shear wall. In some frame the provision of shear
wall gives deflection of shear wall at the top and reduced to
allowable deflection. Providing shear wall to some frames it
is seen that wind forces and shear forces were reduced.
Shear wall based on its elastic and elasto-plastic
performance and found that the permissible deflection at the
top and can reduce the deflection by giving shear wall to the
frame at different location a study was conducted for this.
Alfa Rasikan et al; (2013).In this literature review
they shows that a study was conducted behaviour of wind on
tall building with inclusion of shear wall and without
inclusion of shear wall the study is carried out.the
displacement of included shear wall was 20% less than
without inclusion of shear wall. The paper shows two
models 15 storey and 20 storeys were analyzed and compare
their displacement at top deflection. Study shows that results
were compared at top of a 15 storey building displacement
was reduced when shear wall is provided.
Shameem Ara Bobby Abdul Rahman, and Sayada
Fuadi Fancy (June 2012 ) Drift analysis due to earthquake
and wind loads on tall structures was discussed in this paper.
Thus the effects of lateral loads like winds loads, earthquake
forces are attaining increasing importance and almost every
designer is faced with the problem of providing adequate
strength and stability against lateral loads. For this reason in
recent years wind and earthquake loading have become
determining factors in high -rise building design. This lateral
loads are mainly responsible for drift. So the design of tall
structures must take into consideration of the drift.
Therefore the effect of drift has no specific requirement,
economy and behavior of building has a huge impact on this
Study on Effect of Wind Load and Earthquake Load on Multistorey RC Framed Buildings
(IJSRD/Vol. 3/Issue 10/2015/164)
All rights reserved by www.ijsrd.com 755
issue. In this study the drift effect due to lateral loads like
wind and seismic loads on tall buildings are analyzed.
L.P. Swami and B. Dean Kumar (5.May 2010)
effect of wind on tall building has discussed in this paper.
Gust effectiveness factor method is rational and realistically
analyzed and the wind pressure was known. Hence it is an
important and valid point to be considered for the design of
very tall buildings.
Kareem and T.Kijewski discussed the full-scale
study of the behavior of tall buildings under wind and
earthquake loads i.e. the fundamental differences between
wind and earthquake demand. The study was carried on high
rise 54 storied building and 76 storied building. The result
obtained from analysis shows that wind and earthquake
loads are different from each other and are also different
from static load. The result indicate that earthquake load
excite higher modes that produce less inter storey drift but
higher acceleration which occurs for a relatively short time
compare to wind loads. Although the acceleration under
wind loads is lower than that of earthquake load. It occurs
for longer period that become a comfort issue. However the
drift under wind is larger which raises security issues. It
seems that tall buildings designed for wind are safe under
moderate earthquake loads.
[P.P. Chandurkar et. Al., (2013)], conducted a
study a study on seismic analysis of RCC building with and
without shear walls. They have selected a ten storied
building located in zone II, zone III, zone III, zone IV and
Zone V. Parameter like lateral displacement, story drift and
total cost required for ground floor were calculated in both
the cases
The researchers have mainly focused on wind’s
characteristics, its properties and variations with respect to
wind loads. The scholarly material has a huge gap in
research about buildings’ overall behaviour under wind
loads.
III. METHODS OF ANALYISIS
A. The Location Of The Building Structure Is In
Hyderabad.
The wind speed suggested by IS 875 (part-3) is 44 m/s for
this location. The wind pressure is from the extents of the
rigid diaphragms assigned to the slab elements. Also IS
1983(Part-1):2002 states that wind is not to be considered in
chorus with earthquake or maximum flood or maximum sea
waves. The load case combinations adopted are referred
from IS 875(Part-3):1975,
(D.L + L.L + Wx)
(D.L + L.L - Wx)
(D.L + L.L + Wy)
(D.L + L.L - Wy)
(D.L + Wx)
(D.L - Wx)
(D.L + Wy)
(D.L - Wy)
B. Design Wind Speed (Vz)
The basic wind speed (Vz) for any shall be obtained and
modified to include the following effects to get design wind
velocity at any height ( Vz) for the chosen structure:
1) Risk Level;
2) Terrain roughness, height and size of structure;
3) Local topography
4) It can be methematically expressed as follows:
Vz=Vb K1 K2 K3
Where,
Vz= design wind speed at any height z in m/s
K1= probability factor (risk coefficient)
K2= terrain, heaight and structure size factor
K3= topography factor
C. Terrain and Height Factor (K2)
1) Terrain
Terrain category should be selected due to the effect of
obstruction and possesses the ground roughness surfaces.
The direction of wind consideration depends on terrain
catogory. Wherever sufficient meteorological information is
available about the wind direction, the orientation of any
building or structure may be suitably planned. Terrain in
which a specific structure stands shall be assessed as being
one of the following terrain categories:
1) Category 1 – structure is less than 1.5 m and has no
obstruction at the average height of any object Exposed
open terrain. NOTE – This category includes open sea
coasts and flat treeless plains.
2) Category 2 – Open terrain with well scattered
obstructions having height generally between 1.5 and
10 m. NOTE – This is the criterion for measurement of
regional basic wind speeds and includes airfields, open
parklands and undeveloped sparsely built-up outskirts
of towns and suburbs. Open land adjacent to seacoast
may also be classified as Category 2 due to roughness
of large sea waves at high winds.
3) Category 3 –In this category Terrain with numerous
closely spaced obstructions having the size of building-
structures up to 10 m in height with or without a few
isolated tall structures.
D. Design Wind Pressure
The wind pressure at any height above mean ground level
shall be obtained by the following relationship between
wind pressure and wind speed:
Pz = 0.6 V2
z
Where,
Pz= wind pressure in N/m2 at height z,
Vz = design wind speed in m/s at height z.
E. Wind Load on Individual Members
The necessary formula is adopted for calculating the wind
load on individual structural elements such as roofs and
walls, and individual cladding units and their fittings, it is
necessary to take account of the pressure difference between
opposite faces of such elements or units. Therefore, it
needed to know the internal pressure as well as the external
pressure. Then the wind load, F, acting in a direction normal
to the individual structural element or cladding unit is:
F = (Cpe-Cpi) A Pz
Where, Cpe = exterbnal pressure coefficient
Cpi = internal pressure coefficient
A = surface area of structureal element or cladding unit
Pz = design wind pressure
F. Linear Static Method (Equivalent Static Method)
Earthquake analyses for the structure are carried by
considering assumption that lateral (horizontal) forces are
Study on Effect of Wind Load and Earthquake Load on Multistorey RC Framed Buildings
(IJSRD/Vol. 3/Issue 10/2015/164)
All rights reserved by www.ijsrd.com 756
equivalent to the dynamic or actual loading. The overall
horizontal force also called as base shear on the building is
computed by considering fundamental period of vibration,
structural mass and mode shapes. The total seismic base
shear is divided along the total height of the structure by
means of lateral or horizontal force according to the
formulae specified by the code. The following method is
suitable for building with low to medium height and steady
conformation.
This method is the simplest approach for seismic
analysis of multistoried structures. In this method, the
structure is considered to be elastic when contacted with
static force. The lateral static forces are placed individually
in two principal axes i.e. transverse and longitudinal and
resulting interior forces are mixed up using combination
methods.
The building which is to be analyzed by linear static
method should contain some criteria relating to its stiffness
and geometrical regularity.
1) All members such as columns and walls which are
resisting lateral loads should move from bottom to top.
2) The lateral stiffness and mass should not vary suddenly
from bottom to top.
3) The certain values are to be maintained in the
geometrical asymmetries in the height or in the layout
plans.
This procedure is very suitable and simple for structural
engineer to execute a seismic analysis for reasonable
outcomes. This method is widely used for the buildings and
structures which are having regularity conditions.
IV. RESULTS AND DISCUSSION
A. Displacement Result
Storey
No.
WIND LOAD EARTHQUAKE LOAD
16 96.1 106.7 30.9 33.9
15 94.5 105.3 30.2 33.3
14 92.3 103.2 29.2 32.4
13 89.3 100.3 28 31.1
12 85.6 96.5 26.5 29.5
11 81.1 91.7 24.6 27.6
10 75.7 86.1 30.9 25.4
09 69.5 79.5 22.6 22.9
08 62.6 72.2 20.3 20.4
07 54.9 64 17.9 17.6
06 46.5 55 15.3 14.8
05 37.6 45.3 12.7 11.9
04 28.3 35 10 9
03 19 24.4 7.4 6.1
02 10.2 13.8 4.9 3.4
01 3.2 4.6 2.6 1.1
BASE 0 0 0.8 0
Table 4.1: storey displacements for model 1 along
longitudinal and transverse directions
Fig. 1: Chart. 4.1: Storey wise displacement for building
model-1 along longitudinal direction
Fig. 2: Chart. 4.1.1: Storey wise displacements for building
model-1 Along transverse direction
B. Storey Displacements For Model 2 Along Longitudinal
And Transverse Directions
Storey
No.
WIND LOAD EARTHQUAKE LOAD
16 16.7 14.8 15.8 15.9
15 15.5 13.8 14.6 14.7
14 14.3 12.7 13.4 13.5
13 13.1 11.6 12.2 12.3
12 11.8 10.5 10.9 11
11 10.6 9.4 9.7 9.8
10 9.3 8.3 8.4 8.5
09 8 7.2 7.2 7.3
08 6.8 6 6 6
07 5.6 5 4.8 4.9
06 4.4 3.9 3.8 3.8
05 3.3 2.9 2.8 2.8
04 2.3 2.1 1.9 1.9
03 1.4 1.3 1.2 1.2
Study on Effect of Wind Load and Earthquake Load on Multistorey RC Framed Buildings
(IJSRD/Vol. 3/Issue 10/2015/164)
All rights reserved by www.ijsrd.com 757
02 0.7 0.7 0.6 0.6
01 0.2 0.2 0.2 0.2
BASE 0 0 0 0
Table 4.2: storey displacements for model 2 along
longitudinal and transverse directions
Fig. 3: Chart 4.2: Storey wise displacement for building
model-2 along longitudinal direction
Fig. 4: Chart. 4.2.1: Storey wise displacement for building
model-2 along transverse direction
C. Storey Displacements For Model 3 Along Longitudinal
And Transverse Directions
Storey
No.
WIND LOAD EARTHQUAKE LOAD
16 22.2 19.5 24.1 20.2
15 21.2 18.5 23.2 19.4
14 19.9 17.2 22 18.2
13 18.2 15.4 20.2 16.4
12 16 13.3 17.9 14.2
11 13.5 10.9 15 11.6
10 10.8 8.4 11.8 8.8
09 8.2 6.1 8.6 6.1
08 6.2 4.4 6.1 4.1
07 5.1 3.5 5.1 3.3
06 4 2.8 4 2.6
05 3 2.1 3.1 2
04 2.1 1.4 2.2 1.4
03 1.3 0.9 1.4 0.8
02 0.7 0.4 0.7 0.4
01 0.2 0.1 0.2 0.1
BASE 0 0 0 0
Table 4.3: storey displacements for model 3 along
longitudinal and transverse directions
Fig. 5: Chart. 4.3.1: Storey wise displacement for building
model-3 along longitudinal direction
Fig. 6: Chart. 4.3.2: Storey wise displacement for building
model-3 along transverse direction
D. Storey Drifts
The permissible storey drift according to IS 1893 (Part 1) :
2002 is limited to 0.004 times the storey height, so that
minimum damage would take place during earthquake and
pose less psychological fear in the minds of people. The
Study on Effect of Wind Load and Earthquake Load on Multistorey RC Framed Buildings
(IJSRD/Vol. 3/Issue 10/2015/164)
All rights reserved by www.ijsrd.com 758
maximum storey drifts of different models along
longitudinal and transverse directions obtained from
equivalent static analysis (ETABS) and fro, loads are shown
in tables below.
Storey
No.
WIND LOAD EARTHQUAKE LOAD
16 0.4 0.35 0.175 0.15
15 0.55 0.525 0.25 0.225
14 0.75 0.725 0.3 0.325
13 0.925 0.95 0.375 0.4
12 1.125 1.2 0.475 0.475
11 1.35 1.4 0.5 0.55
10 1.55 1.65 0.575 0.625
09 1.725 1.825 0.6 0.625
08 1.925 2.05 0.65 0.7
07 2.1 2.25 0.65 0.7
06 2.225 2.425 0.675 0.725
05 2.325 2.575 0.65 0.725
04 2.325 2.65 0.625 0.725
03 2.2 2.65 0.575 0.675
02 1.75 2.3 0.45 0.575
01 0.8 1.15 0.2 0.275
BASE 0 0 0 0
Table. 3:
Fig. 7: Chart. 4.4: Inter storey drift of models along with
longitudinal direction
Fig. 8: Chart. 4.4.1: Inter storey drift of models along with
transverse direction
V. CONCLUSIONS
1) A 16 storey building having model 1 model 2 model 3
when compare with wind and earth quake
displacements in longitudinal direction. The wind
displacements of model 2 and model 3 is reduced by
82.62% and 76.90% and earth quake displacement of
model 2 and model 3 is reduced by 48.87% and
22.01%when compared with model 1.hence it is found
that building with shear wall i.e. model 2 resist wind
and earth quake load effectively.
2) A 16 storey building having model 1 model 2 model 3
when compare their wind and earth quake
displacements in transverse direction. The wind
displacements of model 2 and model 3 is reduced by
86.13% and 81.73% and earth quake displacement of
model 2 and model 3 is reduced by 53.10% and
40.05%when compared with model 1.hence it is found
that building with shear wall i.e. model 2 resist wind
and earth quake load effectively.
3) Although A 31 storey building having model 4 model
5 model 6 when compare their wind and earth quake
displacements in longitudinal direction. The wind
displacements of model 5 and model 6 is reduced by
52.42% and 48.48% and earth quake displacement of
model 5 and model 6 is reduced by 48.77% and
42.26%when compared with model 4.hence it is found
that building with shear wall i.e. model 4 resist wind
and earth quake load effectively.
4) A 31 storey building having model 4 model 5 model 6
when compare their wind and earth quake
displacements in transverse direction. The wind
displacements of model 5 and model 6 is reduced by
55.92% and 50.84% and earth quake displacement of
model 5 and model 6 is reduced by 51.90% and
44.33%when compared with model 4.hence it is found
that building with shear wall i.e. model resist wind and
earth quake load effectively.
5) Lateral displacement values obtained from static
method of analysis indicate that shear wall provision
along longitudinal and transverse directions are
effective in reducing the displacement values in the
same directions.
6) The result show that wind and earth quake loads are
different from each other indicates that earth quake
loads produce less inter storey drift compare with the
wind load. Even if inter story drift ratios in tall
buildings may be relatively small with no significant
apparent issue for main force resisting system of
structure similar conclusion were obtained with both
the 16 storey and the 31 storey buildings.
7) From the comparison of story drift values it can be
observed that maximum reduction in drift values is
obtained when shear walls are provided at corners of
the building.
8) Buildings should be designed in both directions
independently for the critical forces of wind or
earthquake separately. The total shear force and the
moment at the base result from seismic analysis when
loads acting normal to the short side may be greater
than the other direction.
9) Composite structures are the best solution for high rise
structure.
Study on Effect of Wind Load and Earthquake Load on Multistorey RC Framed Buildings
(IJSRD/Vol. 3/Issue 10/2015/164)
All rights reserved by www.ijsrd.com 759
10) With improved understanding of tall building
performance, the next generation in design can truly
evolve from the perspectives of performance, economy
and efficiency to advance the growing development of
tall buildings around the globe.
11) For severe lateral loads caused by wind load and or
earthquake load, the reinforced shear wall is obvious.
Because, it produces less deflection and less bending
moment in connecting beams under lateral loads than
all others structural system
VI. ACKNOWLEDGEMENT
My heart full thanks to PROF. Dr.Shreenivas Reddy
Shahpur my beloved guide, PROF. BRIJ BHUSHAN S,
PROF. Rohan Gurav, PROF. Shaik Abdulla for their
valuable Suggestions and Last but not the least I am
indebted to my Parents, Brother, Friends and my colleagues
for their support and supplications.
REFERENCES
[1] Anshuman. S, Dipendu Bhunia , Bhavin Ramjiyani,
Solution of Shear Wall Location in Multistorey
Building, International Journal of Civil and Structural
Engineering,Volume 2, No 2, 2011,493-506.
[2] P. S. Kumbhare, A. C. Saoji, Effectiveness of
Changing Reinforced Concrete Shear Wall Location on
Multi-storeyed Building, International Journal of
Engineering Research and Applications, Vol. 2, Issue
5, September- October 2012, 1072-1076.
[3] Abdur Rahman, Saiada Fuadi Fancy, Shamim Ara
Bobby, Analysis of drift due to wind loads and
earthquake loads on tall structures by programming
language C, International Journal of Scientific and
Engineering Research, Vol. 3, Issue 6, June 2012.
[4] T. Kijewski and A. Kareem, Full-scale study of the
behavior of tall buildings under winds, NatHaz
Modeling Laboratory, Department of Civil
Engineering and Geological Sciences, University of
Notre Dame, Notre Dame, IN 46556.
[5] P.Mendis, T. Ngo, N Haritos, A. Hira, B.Samali, and J.
Cheung, “Wind loading on tall bui;dings,” EJSE
Special Issue: Loading on Structures, vol. 3 pp. 41-54,
2007.
[6] Himalee Rahangdale , S.R.Satone, Design And
Analysis Of Multi storied Building With Effect Of
Shear Wall, Vol. 3, Issue 3, May-Jun 2013, pp.223-
232.
[7] U. H. Varyani, “Structural Design of Multi-Storied
Buildings”, South Asian publishers, New Delhi,
Second edition
[8] IS: 875 (Part 1), “Indian Standard Code of Practice for
design loads for building and structures, Dead Loads”
Bureau of Indian Standards, New Delhi.
[9] IS: 875 (Part 2), “Indian Standard Code of Practice for
design loads for building and structures, Live Loads”
Bureau of Indian Standards, New Delhi
[10]IS: 875 (Part 3), “Indian Standard Code of Practice for
design loads (Other than earthquake) for building and
structures, Wind Loads” Bureau of Indian Standards,
New Delhi
[11]IS 456:2000, “Indian Standard plain and reinforced
concrete-Code of Practice”, Bureau of Indian
Standards, New Delhi, 2000.
[12]IS: 1893-2002, Part 1, “Criteria for Earthquake
Resistant Design of Structures -General Provisions and
Buildings”, Bureau of Indian Standards, New Delhi,
India.
[13]Bungle S. Taranath, ―“wind and earthquake resistant
buildings structural analysis and design”, CRC Press,
Series Editor: Michael D. Meyer. Developed as a
resource for practicing engineers.
[14]El-Leithy, N. F., Hussein, M.M. and Attia, W.A.
Comparative study of structural systems for tall
buildings. Journal of American science, 7 (4), 2011, pp
707-719.
[15]Merrick, R and Bitsuamlak, G. Shape effects on the
wind-induced response of high-rise buildings. Journal
of wind and engineering, 2009. vol.6, No. 2,. pp 1-18.
[16]Halder L.and Dutta,S.C. 2010. Wind effects on multi-
storied buildings: a critical review of Indian codal
provisions with special reference to American
standard, Asian journal of civil engineering (Building
and Housing), 11(3), 2010, 345-370
[17]Ahsan Kareem, “Along-Wind Load Effects on Tall
Buildings” Comparative Study of Major
International Codes and Standards, Journal of
structural engineering, June 2002.
[18]Gajbhiye S.D. and Pande A.M.Critical “study of wind
load effect on high rise building,” M. Tech. Thesis,
submitted to Nagpur University in 2011.
[19]Kijewski T. “Full-scale study of the behavior of tall
buildings under winds,Health Monitoring and
Management of Civil Infrastructure Systems,”
Proceedings of SPIE, 4337,2001.
[20]Krishna Prem “Comparison of wind loads on
medium-rise building” according to Asia-pacific
codes/standards, The seventh Asia-Pacific
Conference on Wind Engineering, November 8-12,
2009, Taipei, Taiwan

More Related Content

PPT
Wind load calculation
PPTX
Design wind load
PPTX
Structural analysis and design of multi storey ppt
PPTX
Wind load
PDF
Rcc structure design by etabs (acecoms)
PPT
COMPARATIVE STUDY OF OUTRIGGER STRUCTURE WITH DIFFERENT CONFIGURATIONS
PDF
Pile Foundations
PPT
Design of columns biaxial bending as per IS 456-2000
Wind load calculation
Design wind load
Structural analysis and design of multi storey ppt
Wind load
Rcc structure design by etabs (acecoms)
COMPARATIVE STUDY OF OUTRIGGER STRUCTURE WITH DIFFERENT CONFIGURATIONS
Pile Foundations
Design of columns biaxial bending as per IS 456-2000

What's hot (20)

PDF
Footing design
PPTX
WIND CODE-IS 875-PART 3
PPT
Design of columns as per IS 456-2000
PPTX
WIND ANALYSIS OF A MULTI STOREY BUILDING WITH AND WITHOUT MASS IRREGURALITY B...
PPSX
Seismic Design Of Structures Project
PDF
Footing design
PDF
Foundation design part_1
PPTX
Baf Shaheen College (B+12) ETABS Dynamic Analysis.pptx
PPT
Design of footing as per IS 456-2000
PPT
Design of columns axial load as per IS 456-2000
PDF
Ductile detailing
PPTX
Earth resistant design philosophy
PPTX
Seismic Analysis
PPTX
Wind effects on structures
PDF
Design notes for seismic design of building accordance to Eurocode 8
PPT
Column design: as per bs code
PDF
Tutorial for design of foundations using safe
PPTX
Overview of IS 16700:2023 (by priyansh verma)
PPTX
Wind loading
PPTX
Retaining walls
Footing design
WIND CODE-IS 875-PART 3
Design of columns as per IS 456-2000
WIND ANALYSIS OF A MULTI STOREY BUILDING WITH AND WITHOUT MASS IRREGURALITY B...
Seismic Design Of Structures Project
Footing design
Foundation design part_1
Baf Shaheen College (B+12) ETABS Dynamic Analysis.pptx
Design of footing as per IS 456-2000
Design of columns axial load as per IS 456-2000
Ductile detailing
Earth resistant design philosophy
Seismic Analysis
Wind effects on structures
Design notes for seismic design of building accordance to Eurocode 8
Column design: as per bs code
Tutorial for design of foundations using safe
Overview of IS 16700:2023 (by priyansh verma)
Wind loading
Retaining walls
Ad

Viewers also liked (20)

PPTX
Effect of wind Load On High Rise Building
PPTX
High-rise structural systems
PPT
Bridge
PPTX
Bridges
PPT
Earthquake ppt
PPTX
types of bridges
PPTX
analysis of high rise building
PPTX
Types of bridges.pptx 1
PPTX
Literature
PPTX
What is a Structural Engineer?
PDF
Vpectrl3 ram steel - gravity column design
PPTX
Seismic response of steel beams coupling concrete walls
DOCX
Earthquake engineering
PPTX
Fire Proofing On Steel Structure
PPT
PDF
ANALYSIS OF WIND & EARTHQUAKE LOAD FOR DIFFERENT SHAPES OF HIGH RISE BUILDING
PPT
Steve Jones - Development of Civil Engineering Design skills through active l...
PPSX
seismic retrofitting using precast elements
PDF
Site Analysis & Precedent Studies
PPTX
Structural engineer drawings
Effect of wind Load On High Rise Building
High-rise structural systems
Bridge
Bridges
Earthquake ppt
types of bridges
analysis of high rise building
Types of bridges.pptx 1
Literature
What is a Structural Engineer?
Vpectrl3 ram steel - gravity column design
Seismic response of steel beams coupling concrete walls
Earthquake engineering
Fire Proofing On Steel Structure
ANALYSIS OF WIND & EARTHQUAKE LOAD FOR DIFFERENT SHAPES OF HIGH RISE BUILDING
Steve Jones - Development of Civil Engineering Design skills through active l...
seismic retrofitting using precast elements
Site Analysis & Precedent Studies
Structural engineer drawings
Ad

Similar to Study on Effect of Wind Load and Earthquake Load on Multi-storey RC Framed Buildings (20)

PDF
Analysis and connection designs of precast load bearing wall
PDF
Performance of High-Rise Steel Building With and Without Bracings
PDF
IRJET- A Research on Comparing the Seismic Effect on Shear Wall Building and ...
PDF
IRJET- Comparative Study on Seismic and Wind Performance of Multi-Storeyed Bu...
PDF
Analysis of Wind Load Effects on R.C Structure Resting on Flat and Sloping Gr...
PDF
Analysis of Wind Load on Tall Building of Various Aspect Ratios
PPTX
Types of Gravitational Loads And Forces
PDF
DESIGN AND ANALYSIS OF CURVED BEAM WITH DIFFERENT OPENINGS
PDF
COMPARATIVE STUDY OF WIND ANALYSIS ON STRUCTURAL SHAPE WITH & WITHOUT SHEAR W...
PDF
Study of Comparison Between Static and Dynamic Analysis Subjected to Wind and...
PDF
Seismic Response of Multi storey Flat Slab Building with and without Shear Wall
PDF
Dynamic Analysis of Multi-Storeyed Frame-Shear Wall Building Considering SSI
PDF
IRJET- Seismic Linear Analysis of Low Rise Open Ground Storey Buildings
PDF
IRJET- Analytical Design for Optimization of Shear Wall for Flat Slab
PDF
The optimum location of shear wall in high rise r.c bulidings under lateral l...
PDF
IRJET- Analysis and Design Of B+G+10 Commercial High-Rise Building under Seis...
PDF
Criticality of Gust Pressures on the Members of Self Standing Towers
PDF
IRJET-Comparing the Effect of Earthquake on Shear wall building and Non-Shear...
PDF
Wind and Seismic Analysis of Building with Bracing System Resting on Sloping ...
PDF
IRJET- Study of Literature on Seismic Response of RC Irregular Structure
Analysis and connection designs of precast load bearing wall
Performance of High-Rise Steel Building With and Without Bracings
IRJET- A Research on Comparing the Seismic Effect on Shear Wall Building and ...
IRJET- Comparative Study on Seismic and Wind Performance of Multi-Storeyed Bu...
Analysis of Wind Load Effects on R.C Structure Resting on Flat and Sloping Gr...
Analysis of Wind Load on Tall Building of Various Aspect Ratios
Types of Gravitational Loads And Forces
DESIGN AND ANALYSIS OF CURVED BEAM WITH DIFFERENT OPENINGS
COMPARATIVE STUDY OF WIND ANALYSIS ON STRUCTURAL SHAPE WITH & WITHOUT SHEAR W...
Study of Comparison Between Static and Dynamic Analysis Subjected to Wind and...
Seismic Response of Multi storey Flat Slab Building with and without Shear Wall
Dynamic Analysis of Multi-Storeyed Frame-Shear Wall Building Considering SSI
IRJET- Seismic Linear Analysis of Low Rise Open Ground Storey Buildings
IRJET- Analytical Design for Optimization of Shear Wall for Flat Slab
The optimum location of shear wall in high rise r.c bulidings under lateral l...
IRJET- Analysis and Design Of B+G+10 Commercial High-Rise Building under Seis...
Criticality of Gust Pressures on the Members of Self Standing Towers
IRJET-Comparing the Effect of Earthquake on Shear wall building and Non-Shear...
Wind and Seismic Analysis of Building with Bracing System Resting on Sloping ...
IRJET- Study of Literature on Seismic Response of RC Irregular Structure

More from IJSRD (20)

PPTX
#IJSRD #Research Paper Publication
PDF
Maintaining Data Confidentiality in Association Rule Mining in Distributed En...
PDF
Performance and Emission characteristics of a Single Cylinder Four Stroke Die...
PDF
Preclusion of High and Low Pressure In Boiler by Using LABVIEW
PDF
Prevention and Detection of Man in the Middle Attack on AODV Protocol
PDF
Comparative Analysis of PAPR Reduction Techniques in OFDM Using Precoding Tec...
PDF
Evaluation the Effect of Machining Parameters on MRR of Mild Steel
PDF
Filter unwanted messages from walls and blocking nonlegitimate user in osn
PDF
Keystroke Dynamics Authentication with Project Management System
PDF
Diagnosing lungs cancer Using Neural Networks
PDF
A Survey on Sentiment Analysis and Opinion Mining
PDF
A Defect Prediction Model for Software Product based on ANFIS
PDF
Experimental Investigation of Granulated Blast Furnace Slag ond Quarry Dust a...
PDF
Product Quality Analysis based on online Reviews
PDF
Solving Fuzzy Matrix Games Defuzzificated by Trapezoidal Parabolic Fuzzy Numbers
PDF
Study of Clustering of Data Base in Education Sector Using Data Mining
PDF
Fault Tolerance in Big Data Processing Using Heartbeat Messages and Data Repl...
PDF
Investigation of Effect of Process Parameters on Maximum Temperature during F...
PDF
Review Paper on Computer Aided Design & Analysis of Rotor Shaft of a Rotavator
PDF
A Survey on Data Mining Techniques for Crime Hotspots Prediction
#IJSRD #Research Paper Publication
Maintaining Data Confidentiality in Association Rule Mining in Distributed En...
Performance and Emission characteristics of a Single Cylinder Four Stroke Die...
Preclusion of High and Low Pressure In Boiler by Using LABVIEW
Prevention and Detection of Man in the Middle Attack on AODV Protocol
Comparative Analysis of PAPR Reduction Techniques in OFDM Using Precoding Tec...
Evaluation the Effect of Machining Parameters on MRR of Mild Steel
Filter unwanted messages from walls and blocking nonlegitimate user in osn
Keystroke Dynamics Authentication with Project Management System
Diagnosing lungs cancer Using Neural Networks
A Survey on Sentiment Analysis and Opinion Mining
A Defect Prediction Model for Software Product based on ANFIS
Experimental Investigation of Granulated Blast Furnace Slag ond Quarry Dust a...
Product Quality Analysis based on online Reviews
Solving Fuzzy Matrix Games Defuzzificated by Trapezoidal Parabolic Fuzzy Numbers
Study of Clustering of Data Base in Education Sector Using Data Mining
Fault Tolerance in Big Data Processing Using Heartbeat Messages and Data Repl...
Investigation of Effect of Process Parameters on Maximum Temperature during F...
Review Paper on Computer Aided Design & Analysis of Rotor Shaft of a Rotavator
A Survey on Data Mining Techniques for Crime Hotspots Prediction

Recently uploaded (20)

PDF
Origin of periodic table-Mendeleev’s Periodic-Modern Periodic table
PPTX
IMMUNITY IMMUNITY refers to protection against infection, and the immune syst...
PDF
RMMM.pdf make it easy to upload and study
PPTX
PPT- ENG7_QUARTER1_LESSON1_WEEK1. IMAGERY -DESCRIPTIONS pptx.pptx
PDF
Anesthesia in Laparoscopic Surgery in India
PDF
STATICS OF THE RIGID BODIES Hibbelers.pdf
PDF
Basic Mud Logging Guide for educational purpose
PDF
Microbial disease of the cardiovascular and lymphatic systems
PPTX
Pharma ospi slides which help in ospi learning
PDF
2.FourierTransform-ShortQuestionswithAnswers.pdf
PPTX
school management -TNTEU- B.Ed., Semester II Unit 1.pptx
PPTX
Microbial diseases, their pathogenesis and prophylaxis
PDF
Mark Klimek Lecture Notes_240423 revision books _173037.pdf
PPTX
BOWEL ELIMINATION FACTORS AFFECTING AND TYPES
PDF
ANTIBIOTICS.pptx.pdf………………… xxxxxxxxxxxxx
PDF
O5-L3 Freight Transport Ops (International) V1.pdf
PDF
Complications of Minimal Access Surgery at WLH
PPTX
The Healthy Child – Unit II | Child Health Nursing I | B.Sc Nursing 5th Semester
PDF
Abdominal Access Techniques with Prof. Dr. R K Mishra
PPTX
Renaissance Architecture: A Journey from Faith to Humanism
Origin of periodic table-Mendeleev’s Periodic-Modern Periodic table
IMMUNITY IMMUNITY refers to protection against infection, and the immune syst...
RMMM.pdf make it easy to upload and study
PPT- ENG7_QUARTER1_LESSON1_WEEK1. IMAGERY -DESCRIPTIONS pptx.pptx
Anesthesia in Laparoscopic Surgery in India
STATICS OF THE RIGID BODIES Hibbelers.pdf
Basic Mud Logging Guide for educational purpose
Microbial disease of the cardiovascular and lymphatic systems
Pharma ospi slides which help in ospi learning
2.FourierTransform-ShortQuestionswithAnswers.pdf
school management -TNTEU- B.Ed., Semester II Unit 1.pptx
Microbial diseases, their pathogenesis and prophylaxis
Mark Klimek Lecture Notes_240423 revision books _173037.pdf
BOWEL ELIMINATION FACTORS AFFECTING AND TYPES
ANTIBIOTICS.pptx.pdf………………… xxxxxxxxxxxxx
O5-L3 Freight Transport Ops (International) V1.pdf
Complications of Minimal Access Surgery at WLH
The Healthy Child – Unit II | Child Health Nursing I | B.Sc Nursing 5th Semester
Abdominal Access Techniques with Prof. Dr. R K Mishra
Renaissance Architecture: A Journey from Faith to Humanism

Study on Effect of Wind Load and Earthquake Load on Multi-storey RC Framed Buildings

  • 1. IJSRD - International Journal for Scientific Research & Development| Vol. 3, Issue 10, 2015 | ISSN (online): 2321-0613 All rights reserved by www.ijsrd.com 754 Study on Effect of Wind Load and Earthquake Load on Multistorey RC Framed Buildings Mohammed Aejaz Ahmed1 Prof. Dr.Shreenivas Reddy Shahpur2 Prof. Brij Bhushan S3 Prof. Rohan Gurav4 Prof. Shaik Abdull5 1 M. Tech Student 2 H.O. D 3,4 Assistant Professor 1,2,3,4 Department of Construction Technology 5 Department of Civil Engineering 1,2,3,4 VTU Regional Center Gulbarga, Karnataka, India 5 KBN college of engineering Gulbarga, Karnataka Abstract— Now a day the increase in the construction of tall buildings, residential and commercial sector, and the new trend are towards taller and slender structures. Though the effect of wind and earthquake, forces becoming important for every structural designer to know. Every engineer is facing with the problem of providing stability, strength for loads like lateral loads. That’s the reason wind as well as earthquake loading have become the influential factors in tall buildings. Loads that are lateral loads play important role for drift. The drift must be taken into consideration for tall structure. The above mentioned are some of the key issues which affect the behavior of structure and economy of the building. This thesis focuses the effects of lateral loads on medium and tall buildings the storey forces, displacements, storey shear, story drift every part of are analyzed on every level of height on the building, Indian codal provision gives us the basic wind speed at 10m height for some important cities/towns. However it does not provide for all the cities in India. In the following work attempt is made to find the effect of lateral loads i.e. wind load and earth quake loads for various models having shear walls and without shear wall. For the study a symmetrical building plan is used with 16 storeys and 31 storeys are analyzed and designed by using structure analysis software tool ETABS-2013. The study also includes the determination of base shear, displacement, storey drift, storey forces and the results are compared with them. These parameters have also considers the effect of shear wall. In order to design a structure to resist wind and earthquake loads, the forces on the structure must be specified. Key words: Steel Slag, Waste Limestone Aggregates, M20 grade concrete, Partial replacement etc I. INTRODUCTION A. General Rapid increase in the construction of tall buildings, commercial as well as residential building leads towards the construction of high rise buildings. Lateral loads similar to wind loads and earthquake loads are thus getting importance. Even though all the designers are facing the problems of getting possible strength and stability not in favour of lateral loads, one of the common used wall which is used for lateral load resisting in tall buildings is the shear wall. Vertical winds are known by the same name whereas the wind loads are known as horizontal winds. Anemometers measure the speed of wind, they are installed at the height of approximately 10 to 30 meters at meteorological observatories on the top of the ground. Thunderstorms, dust storms, cyclonic storms are powerful winds. In our Study we are examining ground plus 15 and ground plus 30 storey building and analyzing design under effect of earthquake and wind by the use of ETABS. Six different models are being analyzed, and thus proving that the shear wall models resist earthquake and wind loads. Then the results are compared and analyzed to achieve the most suitable resisting system and economic structure against the lateral forces. The main factor which differentiates the high, medium and low rise buildings is the effect of lateral load because of the wind. For buildings of up to about 10 storied and of typical properties and the design is rarely affected by the wind loads. Above this height, however, the increase in size of the structural members, and the possible rearrangement of the structure to account for wind load, incurs a cost premium that increases progressively with height. II. LITERATURE REVIEW Anshuman. S, Dipendu Bhunia and Bhavin Ramjiyani , Civil and Structural Engineering, International Journal of Vol 2, (2011) There study shows in multi storey building the solution of shear wall. In some frame the provision of shear wall gives deflection of shear wall at the top and reduced to allowable deflection. Providing shear wall to some frames it is seen that wind forces and shear forces were reduced. Shear wall based on its elastic and elasto-plastic performance and found that the permissible deflection at the top and can reduce the deflection by giving shear wall to the frame at different location a study was conducted for this. Alfa Rasikan et al; (2013).In this literature review they shows that a study was conducted behaviour of wind on tall building with inclusion of shear wall and without inclusion of shear wall the study is carried out.the displacement of included shear wall was 20% less than without inclusion of shear wall. The paper shows two models 15 storey and 20 storeys were analyzed and compare their displacement at top deflection. Study shows that results were compared at top of a 15 storey building displacement was reduced when shear wall is provided. Shameem Ara Bobby Abdul Rahman, and Sayada Fuadi Fancy (June 2012 ) Drift analysis due to earthquake and wind loads on tall structures was discussed in this paper. Thus the effects of lateral loads like winds loads, earthquake forces are attaining increasing importance and almost every designer is faced with the problem of providing adequate strength and stability against lateral loads. For this reason in recent years wind and earthquake loading have become determining factors in high -rise building design. This lateral loads are mainly responsible for drift. So the design of tall structures must take into consideration of the drift. Therefore the effect of drift has no specific requirement, economy and behavior of building has a huge impact on this
  • 2. Study on Effect of Wind Load and Earthquake Load on Multistorey RC Framed Buildings (IJSRD/Vol. 3/Issue 10/2015/164) All rights reserved by www.ijsrd.com 755 issue. In this study the drift effect due to lateral loads like wind and seismic loads on tall buildings are analyzed. L.P. Swami and B. Dean Kumar (5.May 2010) effect of wind on tall building has discussed in this paper. Gust effectiveness factor method is rational and realistically analyzed and the wind pressure was known. Hence it is an important and valid point to be considered for the design of very tall buildings. Kareem and T.Kijewski discussed the full-scale study of the behavior of tall buildings under wind and earthquake loads i.e. the fundamental differences between wind and earthquake demand. The study was carried on high rise 54 storied building and 76 storied building. The result obtained from analysis shows that wind and earthquake loads are different from each other and are also different from static load. The result indicate that earthquake load excite higher modes that produce less inter storey drift but higher acceleration which occurs for a relatively short time compare to wind loads. Although the acceleration under wind loads is lower than that of earthquake load. It occurs for longer period that become a comfort issue. However the drift under wind is larger which raises security issues. It seems that tall buildings designed for wind are safe under moderate earthquake loads. [P.P. Chandurkar et. Al., (2013)], conducted a study a study on seismic analysis of RCC building with and without shear walls. They have selected a ten storied building located in zone II, zone III, zone III, zone IV and Zone V. Parameter like lateral displacement, story drift and total cost required for ground floor were calculated in both the cases The researchers have mainly focused on wind’s characteristics, its properties and variations with respect to wind loads. The scholarly material has a huge gap in research about buildings’ overall behaviour under wind loads. III. METHODS OF ANALYISIS A. The Location Of The Building Structure Is In Hyderabad. The wind speed suggested by IS 875 (part-3) is 44 m/s for this location. The wind pressure is from the extents of the rigid diaphragms assigned to the slab elements. Also IS 1983(Part-1):2002 states that wind is not to be considered in chorus with earthquake or maximum flood or maximum sea waves. The load case combinations adopted are referred from IS 875(Part-3):1975, (D.L + L.L + Wx) (D.L + L.L - Wx) (D.L + L.L + Wy) (D.L + L.L - Wy) (D.L + Wx) (D.L - Wx) (D.L + Wy) (D.L - Wy) B. Design Wind Speed (Vz) The basic wind speed (Vz) for any shall be obtained and modified to include the following effects to get design wind velocity at any height ( Vz) for the chosen structure: 1) Risk Level; 2) Terrain roughness, height and size of structure; 3) Local topography 4) It can be methematically expressed as follows: Vz=Vb K1 K2 K3 Where, Vz= design wind speed at any height z in m/s K1= probability factor (risk coefficient) K2= terrain, heaight and structure size factor K3= topography factor C. Terrain and Height Factor (K2) 1) Terrain Terrain category should be selected due to the effect of obstruction and possesses the ground roughness surfaces. The direction of wind consideration depends on terrain catogory. Wherever sufficient meteorological information is available about the wind direction, the orientation of any building or structure may be suitably planned. Terrain in which a specific structure stands shall be assessed as being one of the following terrain categories: 1) Category 1 – structure is less than 1.5 m and has no obstruction at the average height of any object Exposed open terrain. NOTE – This category includes open sea coasts and flat treeless plains. 2) Category 2 – Open terrain with well scattered obstructions having height generally between 1.5 and 10 m. NOTE – This is the criterion for measurement of regional basic wind speeds and includes airfields, open parklands and undeveloped sparsely built-up outskirts of towns and suburbs. Open land adjacent to seacoast may also be classified as Category 2 due to roughness of large sea waves at high winds. 3) Category 3 –In this category Terrain with numerous closely spaced obstructions having the size of building- structures up to 10 m in height with or without a few isolated tall structures. D. Design Wind Pressure The wind pressure at any height above mean ground level shall be obtained by the following relationship between wind pressure and wind speed: Pz = 0.6 V2 z Where, Pz= wind pressure in N/m2 at height z, Vz = design wind speed in m/s at height z. E. Wind Load on Individual Members The necessary formula is adopted for calculating the wind load on individual structural elements such as roofs and walls, and individual cladding units and their fittings, it is necessary to take account of the pressure difference between opposite faces of such elements or units. Therefore, it needed to know the internal pressure as well as the external pressure. Then the wind load, F, acting in a direction normal to the individual structural element or cladding unit is: F = (Cpe-Cpi) A Pz Where, Cpe = exterbnal pressure coefficient Cpi = internal pressure coefficient A = surface area of structureal element or cladding unit Pz = design wind pressure F. Linear Static Method (Equivalent Static Method) Earthquake analyses for the structure are carried by considering assumption that lateral (horizontal) forces are
  • 3. Study on Effect of Wind Load and Earthquake Load on Multistorey RC Framed Buildings (IJSRD/Vol. 3/Issue 10/2015/164) All rights reserved by www.ijsrd.com 756 equivalent to the dynamic or actual loading. The overall horizontal force also called as base shear on the building is computed by considering fundamental period of vibration, structural mass and mode shapes. The total seismic base shear is divided along the total height of the structure by means of lateral or horizontal force according to the formulae specified by the code. The following method is suitable for building with low to medium height and steady conformation. This method is the simplest approach for seismic analysis of multistoried structures. In this method, the structure is considered to be elastic when contacted with static force. The lateral static forces are placed individually in two principal axes i.e. transverse and longitudinal and resulting interior forces are mixed up using combination methods. The building which is to be analyzed by linear static method should contain some criteria relating to its stiffness and geometrical regularity. 1) All members such as columns and walls which are resisting lateral loads should move from bottom to top. 2) The lateral stiffness and mass should not vary suddenly from bottom to top. 3) The certain values are to be maintained in the geometrical asymmetries in the height or in the layout plans. This procedure is very suitable and simple for structural engineer to execute a seismic analysis for reasonable outcomes. This method is widely used for the buildings and structures which are having regularity conditions. IV. RESULTS AND DISCUSSION A. Displacement Result Storey No. WIND LOAD EARTHQUAKE LOAD 16 96.1 106.7 30.9 33.9 15 94.5 105.3 30.2 33.3 14 92.3 103.2 29.2 32.4 13 89.3 100.3 28 31.1 12 85.6 96.5 26.5 29.5 11 81.1 91.7 24.6 27.6 10 75.7 86.1 30.9 25.4 09 69.5 79.5 22.6 22.9 08 62.6 72.2 20.3 20.4 07 54.9 64 17.9 17.6 06 46.5 55 15.3 14.8 05 37.6 45.3 12.7 11.9 04 28.3 35 10 9 03 19 24.4 7.4 6.1 02 10.2 13.8 4.9 3.4 01 3.2 4.6 2.6 1.1 BASE 0 0 0.8 0 Table 4.1: storey displacements for model 1 along longitudinal and transverse directions Fig. 1: Chart. 4.1: Storey wise displacement for building model-1 along longitudinal direction Fig. 2: Chart. 4.1.1: Storey wise displacements for building model-1 Along transverse direction B. Storey Displacements For Model 2 Along Longitudinal And Transverse Directions Storey No. WIND LOAD EARTHQUAKE LOAD 16 16.7 14.8 15.8 15.9 15 15.5 13.8 14.6 14.7 14 14.3 12.7 13.4 13.5 13 13.1 11.6 12.2 12.3 12 11.8 10.5 10.9 11 11 10.6 9.4 9.7 9.8 10 9.3 8.3 8.4 8.5 09 8 7.2 7.2 7.3 08 6.8 6 6 6 07 5.6 5 4.8 4.9 06 4.4 3.9 3.8 3.8 05 3.3 2.9 2.8 2.8 04 2.3 2.1 1.9 1.9 03 1.4 1.3 1.2 1.2
  • 4. Study on Effect of Wind Load and Earthquake Load on Multistorey RC Framed Buildings (IJSRD/Vol. 3/Issue 10/2015/164) All rights reserved by www.ijsrd.com 757 02 0.7 0.7 0.6 0.6 01 0.2 0.2 0.2 0.2 BASE 0 0 0 0 Table 4.2: storey displacements for model 2 along longitudinal and transverse directions Fig. 3: Chart 4.2: Storey wise displacement for building model-2 along longitudinal direction Fig. 4: Chart. 4.2.1: Storey wise displacement for building model-2 along transverse direction C. Storey Displacements For Model 3 Along Longitudinal And Transverse Directions Storey No. WIND LOAD EARTHQUAKE LOAD 16 22.2 19.5 24.1 20.2 15 21.2 18.5 23.2 19.4 14 19.9 17.2 22 18.2 13 18.2 15.4 20.2 16.4 12 16 13.3 17.9 14.2 11 13.5 10.9 15 11.6 10 10.8 8.4 11.8 8.8 09 8.2 6.1 8.6 6.1 08 6.2 4.4 6.1 4.1 07 5.1 3.5 5.1 3.3 06 4 2.8 4 2.6 05 3 2.1 3.1 2 04 2.1 1.4 2.2 1.4 03 1.3 0.9 1.4 0.8 02 0.7 0.4 0.7 0.4 01 0.2 0.1 0.2 0.1 BASE 0 0 0 0 Table 4.3: storey displacements for model 3 along longitudinal and transverse directions Fig. 5: Chart. 4.3.1: Storey wise displacement for building model-3 along longitudinal direction Fig. 6: Chart. 4.3.2: Storey wise displacement for building model-3 along transverse direction D. Storey Drifts The permissible storey drift according to IS 1893 (Part 1) : 2002 is limited to 0.004 times the storey height, so that minimum damage would take place during earthquake and pose less psychological fear in the minds of people. The
  • 5. Study on Effect of Wind Load and Earthquake Load on Multistorey RC Framed Buildings (IJSRD/Vol. 3/Issue 10/2015/164) All rights reserved by www.ijsrd.com 758 maximum storey drifts of different models along longitudinal and transverse directions obtained from equivalent static analysis (ETABS) and fro, loads are shown in tables below. Storey No. WIND LOAD EARTHQUAKE LOAD 16 0.4 0.35 0.175 0.15 15 0.55 0.525 0.25 0.225 14 0.75 0.725 0.3 0.325 13 0.925 0.95 0.375 0.4 12 1.125 1.2 0.475 0.475 11 1.35 1.4 0.5 0.55 10 1.55 1.65 0.575 0.625 09 1.725 1.825 0.6 0.625 08 1.925 2.05 0.65 0.7 07 2.1 2.25 0.65 0.7 06 2.225 2.425 0.675 0.725 05 2.325 2.575 0.65 0.725 04 2.325 2.65 0.625 0.725 03 2.2 2.65 0.575 0.675 02 1.75 2.3 0.45 0.575 01 0.8 1.15 0.2 0.275 BASE 0 0 0 0 Table. 3: Fig. 7: Chart. 4.4: Inter storey drift of models along with longitudinal direction Fig. 8: Chart. 4.4.1: Inter storey drift of models along with transverse direction V. CONCLUSIONS 1) A 16 storey building having model 1 model 2 model 3 when compare with wind and earth quake displacements in longitudinal direction. The wind displacements of model 2 and model 3 is reduced by 82.62% and 76.90% and earth quake displacement of model 2 and model 3 is reduced by 48.87% and 22.01%when compared with model 1.hence it is found that building with shear wall i.e. model 2 resist wind and earth quake load effectively. 2) A 16 storey building having model 1 model 2 model 3 when compare their wind and earth quake displacements in transverse direction. The wind displacements of model 2 and model 3 is reduced by 86.13% and 81.73% and earth quake displacement of model 2 and model 3 is reduced by 53.10% and 40.05%when compared with model 1.hence it is found that building with shear wall i.e. model 2 resist wind and earth quake load effectively. 3) Although A 31 storey building having model 4 model 5 model 6 when compare their wind and earth quake displacements in longitudinal direction. The wind displacements of model 5 and model 6 is reduced by 52.42% and 48.48% and earth quake displacement of model 5 and model 6 is reduced by 48.77% and 42.26%when compared with model 4.hence it is found that building with shear wall i.e. model 4 resist wind and earth quake load effectively. 4) A 31 storey building having model 4 model 5 model 6 when compare their wind and earth quake displacements in transverse direction. The wind displacements of model 5 and model 6 is reduced by 55.92% and 50.84% and earth quake displacement of model 5 and model 6 is reduced by 51.90% and 44.33%when compared with model 4.hence it is found that building with shear wall i.e. model resist wind and earth quake load effectively. 5) Lateral displacement values obtained from static method of analysis indicate that shear wall provision along longitudinal and transverse directions are effective in reducing the displacement values in the same directions. 6) The result show that wind and earth quake loads are different from each other indicates that earth quake loads produce less inter storey drift compare with the wind load. Even if inter story drift ratios in tall buildings may be relatively small with no significant apparent issue for main force resisting system of structure similar conclusion were obtained with both the 16 storey and the 31 storey buildings. 7) From the comparison of story drift values it can be observed that maximum reduction in drift values is obtained when shear walls are provided at corners of the building. 8) Buildings should be designed in both directions independently for the critical forces of wind or earthquake separately. The total shear force and the moment at the base result from seismic analysis when loads acting normal to the short side may be greater than the other direction. 9) Composite structures are the best solution for high rise structure.
  • 6. Study on Effect of Wind Load and Earthquake Load on Multistorey RC Framed Buildings (IJSRD/Vol. 3/Issue 10/2015/164) All rights reserved by www.ijsrd.com 759 10) With improved understanding of tall building performance, the next generation in design can truly evolve from the perspectives of performance, economy and efficiency to advance the growing development of tall buildings around the globe. 11) For severe lateral loads caused by wind load and or earthquake load, the reinforced shear wall is obvious. Because, it produces less deflection and less bending moment in connecting beams under lateral loads than all others structural system VI. ACKNOWLEDGEMENT My heart full thanks to PROF. Dr.Shreenivas Reddy Shahpur my beloved guide, PROF. BRIJ BHUSHAN S, PROF. Rohan Gurav, PROF. Shaik Abdulla for their valuable Suggestions and Last but not the least I am indebted to my Parents, Brother, Friends and my colleagues for their support and supplications. REFERENCES [1] Anshuman. S, Dipendu Bhunia , Bhavin Ramjiyani, Solution of Shear Wall Location in Multistorey Building, International Journal of Civil and Structural Engineering,Volume 2, No 2, 2011,493-506. [2] P. S. Kumbhare, A. C. Saoji, Effectiveness of Changing Reinforced Concrete Shear Wall Location on Multi-storeyed Building, International Journal of Engineering Research and Applications, Vol. 2, Issue 5, September- October 2012, 1072-1076. [3] Abdur Rahman, Saiada Fuadi Fancy, Shamim Ara Bobby, Analysis of drift due to wind loads and earthquake loads on tall structures by programming language C, International Journal of Scientific and Engineering Research, Vol. 3, Issue 6, June 2012. [4] T. Kijewski and A. Kareem, Full-scale study of the behavior of tall buildings under winds, NatHaz Modeling Laboratory, Department of Civil Engineering and Geological Sciences, University of Notre Dame, Notre Dame, IN 46556. [5] P.Mendis, T. Ngo, N Haritos, A. Hira, B.Samali, and J. Cheung, “Wind loading on tall bui;dings,” EJSE Special Issue: Loading on Structures, vol. 3 pp. 41-54, 2007. [6] Himalee Rahangdale , S.R.Satone, Design And Analysis Of Multi storied Building With Effect Of Shear Wall, Vol. 3, Issue 3, May-Jun 2013, pp.223- 232. [7] U. H. Varyani, “Structural Design of Multi-Storied Buildings”, South Asian publishers, New Delhi, Second edition [8] IS: 875 (Part 1), “Indian Standard Code of Practice for design loads for building and structures, Dead Loads” Bureau of Indian Standards, New Delhi. [9] IS: 875 (Part 2), “Indian Standard Code of Practice for design loads for building and structures, Live Loads” Bureau of Indian Standards, New Delhi [10]IS: 875 (Part 3), “Indian Standard Code of Practice for design loads (Other than earthquake) for building and structures, Wind Loads” Bureau of Indian Standards, New Delhi [11]IS 456:2000, “Indian Standard plain and reinforced concrete-Code of Practice”, Bureau of Indian Standards, New Delhi, 2000. [12]IS: 1893-2002, Part 1, “Criteria for Earthquake Resistant Design of Structures -General Provisions and Buildings”, Bureau of Indian Standards, New Delhi, India. [13]Bungle S. Taranath, ―“wind and earthquake resistant buildings structural analysis and design”, CRC Press, Series Editor: Michael D. Meyer. Developed as a resource for practicing engineers. [14]El-Leithy, N. F., Hussein, M.M. and Attia, W.A. Comparative study of structural systems for tall buildings. Journal of American science, 7 (4), 2011, pp 707-719. [15]Merrick, R and Bitsuamlak, G. Shape effects on the wind-induced response of high-rise buildings. Journal of wind and engineering, 2009. vol.6, No. 2,. pp 1-18. [16]Halder L.and Dutta,S.C. 2010. Wind effects on multi- storied buildings: a critical review of Indian codal provisions with special reference to American standard, Asian journal of civil engineering (Building and Housing), 11(3), 2010, 345-370 [17]Ahsan Kareem, “Along-Wind Load Effects on Tall Buildings” Comparative Study of Major International Codes and Standards, Journal of structural engineering, June 2002. [18]Gajbhiye S.D. and Pande A.M.Critical “study of wind load effect on high rise building,” M. Tech. Thesis, submitted to Nagpur University in 2011. [19]Kijewski T. “Full-scale study of the behavior of tall buildings under winds,Health Monitoring and Management of Civil Infrastructure Systems,” Proceedings of SPIE, 4337,2001. [20]Krishna Prem “Comparison of wind loads on medium-rise building” according to Asia-pacific codes/standards, The seventh Asia-Pacific Conference on Wind Engineering, November 8-12, 2009, Taipei, Taiwan